REV 1-M-105 NEW WORK SECT 11-12.pdf

PDF 213 KB Posted

Attached to
Project: CSC-20049 Water Heater (Solar) Improvements Bldg 11
Solicitation number
SP4702-22-R-0011
Issued by

About this file

This solicitation requests proposals for a water heater solar improvements project at a Defense Logistics Agency facility in Columbus, Ohio. The project scope involves furnishing all labor, equipment, materials and supervision to install a new solar water heating system including a solar collector array, water tank, heat pump water heater, piping and controls. Proposals are due by August 22nd and the contract is set aside for small businesses. The award will be a firm fixed-price contract made to the responsible offeror submitting the lowest priced technically acceptable proposal meeting all requirements. The period of performance is 540 days from notice to proceed. A pre-proposal site visit will be held on August 1st. Questions are due by August 8th. Davis Bacon prevailing wage rates apply.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

v

CL

v

ROOM

EQUIPMENT

EM

L

T

EM

L

T

SW

BD

0-

LP

0-

W

LP

0-

E

EL

P

N L

SW

BD

1-

LP

LP

F

S

F

C F

LP

LP

R O

O M

EQ

U

IP

M

EN

T

T

LP122

LP

PP

EM LT

F F

F

F

NAC

EM

L

T

EM

L

T F F

SIR

SIR

PT

D F

F

'-6

1 16

T

PP

A/C

T

1240 1242

SW

BD

0-

LP

0-

W

LP

0-

E

LP

LP

SW

BD

0-

LP

0-

W

LP

0-

E

LP

LP

BU

IL

D

IN

G

AU

D

IT

O R

IU

M

BA

C

KS

TA

G E

5" EXTG STEAM LINE

2" EXTG CONDENSATE

LINE

LP

S

LPSLPS

LPSLP

S

LPSLPS

LP

S

H W

S

LPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPSLPS LPS LPS LPS LPS LPS LPS LPS LPS LPS LPS LPS LPS LPS LPS LPS LPS LPS

CDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCDCD CD CD CD CD CD CD CD CD CD CD CD CD CD CD CD CD CD

C D

C D

C D

C D

C D

C

DC

D C

D

HOT WATER

PUMP

HWRHWRHWRHWRHWRHWRHWRHWRHWR

H W

S H

W S

H W

R

HWR

HWS

HWSHWS

H W

S

HWS HWS HWS HWS HWS HWS

HWSHWS

HWS

H W

S

HWR

H W

R

H W

R H

W R

H W

R

DHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHW

2-1/2"

1-1/4"

1"

4"

2-1/2"

2"

DHW

PNL-11-11-PP-3

MECHANICAL

D H

W D

H W

DHW DHW DHW DHW DHW DHW DHW DHW DHW DHW DHW DHW DHW DHW DHW DHW DHW DHW DHW DHW DHW

DHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHW

DHW

DHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHWDHW

4"

HWS HWS HWS HWS HWS HWS HWS

HWR HWR HWR

HWS HWS HWS HWS HWS HWS HWS HWS HWS HWS HWS

H W

S H

W S

H W

S H

W S

HWS

G

LY

G

LY

HWR HWR HWR HWR HWR HWR HWR HWR HWR

HWRHWRHWRHWRHWRHWRHWRHWRHWRHWRHWR

A

A

A

A

A

A

A

A

A

A

A

HWRHWRHWRHWRHWRHWRHWRHWRHWRHWRHWRHWRHWRHWRHWRHWRHWRHWRHWRHWRHWRHWRHWR

HWS HWS HWS HWS HWS HWS HWS HWS HWS HWS HWS HWS HWS HWS HWS

3" 2-1/2"

3" 3"

HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR

2"

4"

HWS

2"

DHW

1"

1"

SWB-11-11-MDP-2

DHW

SWB-11-11-MDP-3

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

M

AR

K D

AT

E

D R

AW

N

B Y:

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A SHEET ID

DLA INSTALLATION MANAGEMENT

D E

F E

N S

E

L O

G I S T

I C

S

A G

E N

C Y

PR

O

JE

C

T N

O

D

EF

EN

SE

L O

G

IS

TI

C

S

AG

EN

C

Y

D

EF

EN

SE

S U

PP

LY

C

EN

TE

R

C O

LU

M

BU

S

C O

LU

M

BU

S, O H

IO

-3

IN

ST

AL

LA

TI

O

N M

AN

AG

EM

EN

T D

IV

IS

IO

N

D

LA

IN

ST

AL

LA

TI

O

N M

AN

AG

EM

EN

T

BU

IL

D

IN

G

C H

EC

KE

D B

Y:

C H

EC

KE

D B

Y:

C H

EC

KE

D B

Y:

FU

LL

S C

AL

E:

D

AT

E:

C H

EC

KE

D B

Y:

C H

EC

KE

D B

Y:

AP

PR

O

VE

D B

Y:

H

AL

F

SC

AL

E:

"X

1'

'-0

-A ug -2

"X

1'

'-0

FA

C

IL

IT

Y

EN

G

IN

EE

R

D

EP

U

TY

F

AC

IL

IT

Y

EN

G

IN

EE

R

C U

ST

O

M

ER

D

LA

L &M

(S

AF

ET

Y)

D M

-F C

S(

SE

C U

R

IT

Y)

D M

-F C

E(

EN

VI

R

O N

M

EN

TA

L)

A

U G

C H

AN

G

ES

T

O C

O D

ED

N

O

TE

S

4-584 M-105

KE

N

T

KL

IN

G

LE

R

KE

N

T

KL

IN

G

LE

R

C

SC

-2

W

AT

ER

H

EA

TE

R (S

O

LA

R ) I

M

PR

O

VE

M

EN

TS

, B

LD

G

. 1

BU

IL

D

IN

G

SE

C

TI

O N

S

- N

EW

M

EC

H

AN

IC

AL

W

O R

K

PL

AN

SCALE: 3/32" = 1'-0"

BUILDING 11 SECTION 11 & 12 - NEW MECHANICAL WORK PLAN

1 1

WH-11-11-1

GENERAL NOTES: M-101 THRU M-106

1. SOLAR COLLECTOR ARRAY AND PIPING ON ROOF NOT SHOWN ON

DRAWING FOR CLARITY. SEE LAYOUT ON SHEETS M-401 THRU M-403.

2. HOT WATER SUPPLY/RETURN (HWS/HWR) PIPING SHALL BE ASTM

A53/A53M, GRADE B, SCHEDULE 40, BLACK STEEL, SEAMLESS. WHERE

PIPE NEEDS REDUCED USE ECCENTRIC REDUCERS INSULATE NEW

HWS/HWR PIPE WITH 2" MINERAL FIBER WITH ALL SERVICE JACKET.

INSTALL PIPING AT A MINIMUM 13 FEET AFF.

3. ALL NEW DOMESTIC HOT WATER AND COLD WATER SHALL BE ASTM

B88M, COPPER TUBE, TYPE L. INSULATE NEW DOMESTIC HOT WATER

AND COLD WATER PIPING WITH 1" FLEXIBLE ELASTOMERIC INSULATION.

4. ALL EXTERIOR WATER/GLYCOL PIPING INSULATION SHALL HAVE AN

ALUMINUM WEATHER PROOF JACKET.

5. NEW GAS PIPING SHALL BE STEEL PIPE CONFORMING TO ASME B36.10M;

AND MALLEABLE-IRON THREADED FITTINGS CONFORMING TO ASME

B16.1 AND ASME B16.3.

6. PROVIDE NEW MANUFACTURERS STANDARDIZATION SOCIETY OF

VALVES AND FITTINGS (MSS) TYPE 43 HANGERS WITH TYPE 40

PROTECTIVE SHIELD PIPING. SPACE HANGERS PER MSS 58

GUIDELINES.

7. WATER DISTRIBUTION SYSTEM SHALL BE BALANCED IN ACCORDANCE

WITH SECTION 23 05 93.00 06 TESTING, ADJUSTING AND BALANCING FOR

HVAC OF THE PROJECT SPECIFICATIONS.

8. PIPING AND HEATER LOCATIONS ARE SCHEMATIC IN NATURE. PIPING,

UNIT HEATERS AND BOILERS SHOWN ARE PROVIDED TO SHOW

SUFFICIENT DETAIL FOR BIDDING AND EXECUTION. ACTUAL

INSTALLATION IN FIELD MAY BE REVISED (WITH GOVERNMENT

APPROVAL) TO EASE INSTALLATION.

9. PROVIDE PIPE SLEEVES WHERE PIPES PASS THROUGH MASONRY OR

CONCRETE WALLS. SLEEVES SHALL BE OF SUFFICIENT LENGTH TO

PASS THROUGH ENTIRE THICKNESS OF WALLS. SEAL ALL

PENETRATIONS TO 3 HR FIRE RATING.

CODED NOTES:

1. INSTALL NEW THERMOSTATIC MIXING VALVE. PROVIDE PIPING AS

SHOWN ON TYPICAL MIXING VALVE TO FIXTURES SCHEMATIC SHEET

M-504.

2. INSTALL SOLAR WATER TANK IN ACCORDANCE WITH MANUFACTURER'S

RECOMMENDATIONS. SEE PIPING SCHEMATIC SHEET M-504. SEE UNIT

SCHEDULE SHEET M-601.

3. INSTALL NEW HEAT PUMP WATER HEATER IN ACCORDANCE WITH

MANUFACTURER'S RECOMMENDATIONS. SEE PIPING SCHEMATIC

SHEET M-504. SEE SCHEDULE SHEET M-601.

4. INSTALL NEW INLINE CIRCULATING PUMP. INSTALL PUMP PER

MANUFACTURER'S RECOMMENDATIONS. SEE DETAIL SHEET M-501.

SEE SCHEDULE SHEET M-602.

5. INSTALL NEW 55 GALLON GLYCOL FEEDER. INSTALL IN ACCORDANCE

WITH MANUFACTURER'S RECOMMENDATIONS. SEE PIPING SCHEMATIC

SHEET M-504.

6. PROVIDE 2" HOT WATER BYPASS PIPE WITH CONTROL VALVE.

7. CONNECT NEW HOT WATER SUPPLY/RETURN PIPING TO EXISTING HOT

WATER SUPPLY/RETURN. SEE PIPING SCHEMATIC DETAIL M-502.

EXPANSION LOOP

4'-6" x 2'-6" x 4'-6"

EXPANSION LOOP

5'-0" x 2'-6" x 5'-0"

EXPANSION LOOP

4'-0" x 2'-0" x 4'-0" EXPANSION LOOP

5'-0" x 2'-6" x 5'-0"

PIPE DOWN FROM SOLAR COLLECTOR ARRAY

GF-11-11-1

SWT-11-11-1

SGP-11-11-1

DHWP-11-11-1

7 6

AutoCAD SHX Text

NORTH

File details come from the government source that posted it. Updated .