This document outlines a federal contract solicitation for maintenance services at Defense Supply Center Columbus facilities. The Defense Logistics Agency is seeking proposals for operation, maintenance, and repair of HVAC, plumbing, and emergency power supply systems across various buildings. Key requirements include qualified staffing and certifications to perform tasks to standards referenced in the solicitation. The contract will be a firm fixed-price award made to the lowest priced technically acceptable proposal. Proposals are due by August 20, 2021. The period of performance is 365 calendar days from notice to proceed.
View the file
Other files
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Facility Name: | Defense Supply Center Columbus |
| Address: | 3990 East Broad Street, Columbus Ohio 43218 |
| Location | Type | Cleaning Frequency | Fats, Oils, and Grease Type | Size (Approx) | Make | Model |
| Building 20 | Kitchen Grease Interceptor | 12 times/year @1 month intervals | Food Service Establishment | 50 gallon | ||
| Building 20 | Grease Trap (Basement) | 4 times/year @3 months intervals | Janitorial Wash Down | 50 gallon | ||
| Building 20 | Trench Drain & Lift Pump | 4 times/year @3 months intervals | Storm Water | 1000 gallon | ||
| Building 22 | Kitchen Grease Interceptor | Not in Contract | Food Service Establishment | 50 gallon | ||
| Building 27 | Oil Water Separator/Trench Drain | 4 times / year @ 3 month intervals | Golf Course Vehicle Maintenance/Wash | 125 gallon | Zurn | Z188-ST-75 |
| Building 43 | Oil Water Separator | 4 times/year @3 months intervals | Vehicle Maintenance/Wash | 1000 gallon | E.C. Babbert | Modified Model O-10 Oil Interceptor |
| Building 43 | Trench Drain | 4 times/year @3 months intervals | Vehicle Maintenance/Wash | |||
| Building 46 | Oil Water Separator | 4 times/year @3 months intervals | Fire Apparatus Vehicle Wash Area/Basin (South Driveway) | 350 gallon | ||
| Building 46 | Trench Drain | 4 times/year @3 months intervals | Vehicle Maintenance/Wash | 1 ft x 50 ft | located inside the building 46 Apparatus Bay | |
| Building 1 | Kitchen Grease Interceptor | 2 times/year @6 months intervals | Food Service Establishment | 2 x 750 gallon | Hancor | |
| Building 2 | Kitchen Grease Interceptor | 2 times/year @6 months intervals | Food Service Establishment | 500 gallon | Mack Industries | |
| Building 4 | Oil Water Separator | 2 times/year @6 months intervals | Vehicle Maintenance/Wash | 1200 gallon | Mack Industries | Traffic Bearing OS w/ 160 cf capacity |
| Building 4 | Trench Drain | 2 times/year @6 months intervals | Vehicle Maintenance/Wash | |||
| Building 201 | Not in Contract | |||||
| Building 21 | Kitchen Grease Interceptor | Not in Contract | Food Service Establishment | 50 gallon |