SOQ26_9357_OQ_Addendum_No._3_Issue.pdf

PDF 181 KB Posted

Attached to
SOQ26 9357 OQ Prequalification for Fern Creek UG 230kV T-Line and Water Main Civil Construction Services
Solicitation number
9357
Issued by
Florida

About this file

This is Addendum 3 to a Statement of Qualifications (SOQ) issued by the Orlando Utilities Commission for prequalification of contractors for Fern Creek Underground 230kV Transmission Line and Water Main Civil Construction Services. The project scope includes civil construction for underground transmission line ductbank installation spanning approximately 4,975 feet with eight 8-inch conduits, two 4-inch conduits, and two 2-inch conduits, along with three splice vaults and two communication handholes. The water main component involves replacement of approximately 3,000 linear feet of water mains along Fern Creek Avenue, including fire hydrants, isolation valves, and cathodic protection. Roadway restoration requires historically designated brick paver replacement in the historic district and asphalt restoration in other areas. Addendum 3 extends the SOQ response due date from August 11, 2026 to August 14, 2026 at 2:00 p.m. EST, with responses submitted through VendorLink. The questions period closed on July 23, 2026 and is not being extended. Bidders who previously submitted responses may update their submissions prior to the new deadline.

Qualified contractors must meet minimum requirements including seven years in business, Florida licensure, $30 million bonding capacity, three or more similar projects as lead prime within the past seven years, and an OSHA Experience Modification Rate of 1.0 or less for 2023-2025. Insurance requirements include General Liability of $5 million, Auto Liability of $1 million with MCS-90 endorsement, statutory Workers' Compensation, and Pollution Liability of $5 million. Project managers and superintendents must have seven years' experience on similar projects. The total project estimate is $25 million, with work anticipated to begin in first quarter 2027. Responses scoring below 2.0 out of 5.0 in any evaluation category or below 3.0 overall will not prequalify. Automatic disqualification applies to late submissions, inadequate licensing, bonding, insurance, OSHA EMR exceeding 1.0, or deficient project references. Respondents must acknowledge receipt of Addendum 3 in their submissions, and all communications regarding the SOQ must be directed to Rob McCarty, Buyer of Record, at rmccarty@ouc.com or 407-434-3101.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SOQ26 9357 OQ

SOQ26 9357 OQ

Préqualification for Fern Creek 230kV Underground Transmission Line and Water Main Civil Construction Services

ADDENDUM 3

DATED: August 11, 2026

SOQ26 9357 OQ has been amended as stated below (or on the following page).

In your Response submittal, you MUST note that Addendum 3 was received OR YOUR RESPONSE MAY BE CONSIDERED NON- RESPONSIVE. If additional information is required regarding this SOQ, please feel free to contact the buyer of record at rmccarty@ouc.com. Thank you for your participation in this SOQ.

Please be advised the SOQ Response Schedule has is Amended to the Following:

The Due date for the Responses to this SOQ has been extended from 8/11/26 to August 14, 2026, at 2:00 pm. All responses to be submitted through VendorLink.

The Questions period is not being extended and is closed.

Any firms that have already submitted through VendorLink may make any updates to their response prior to the new due date and time in VendorLink.

Note: There shall be no communication between the respondent, their employees or subcontractors concerning this SOQ to anyone within OUC except the buyer of record. Responses are due by 2:00 p.m.

EST. August 14, 2026. The last day for submitting questions is July 23, 2026.

Sincerely, Orlando Utilities Commission Rob McCarty, Sr. Buyer Ph# 407-434-3101 Fax 407-434-5088

Orlando Utilities Commission P.O. Box 3193 Orlando Florida 32802 Purchasing: 100 W. Anderson St. Orlando, FL 32822 Phone: 407.434.4048 Fax: 407.434.4338 Website: www.ouc.com

Orlando Utilities Commission
SOQ26 9357 OQ
ADDENDUM 3
SOQ26 9357 OQ has been amended as stated below (or on the following page).

File details come from the government source that posted it. Updated .