Letter_of_Qualification_Status___SOQ26_9357_OQ.pdf
PDF 148 KB Posted
- Attached to
- SOQ26 9357 OQ Prequalification for Fern Creek UG 230kV T-Line and Water Main Civil Construction Services
- Solicitation number
- 9357
- Issued by
- Florida
About this file
This is a Letter of Qualification Status from the Orlando Utilities Commission (OUC) notifying firms of their prequalification status for the Fern Creek Underground 230kV Transmission Line and Water Main Civil Construction Services project (SOQ26 9357 OQ). The project encompasses civil construction services including underground transmission line ductbank installation spanning approximately 4,975 linear feet with eight 8-inch conduits, two 4-inch conduits, and two 2-inch conduits, along with three splice vaults and two communication handholes. Additionally, the scope includes replacement of approximately 3,000 linear feet of water mains along Fern Creek Avenue with associated fire hydrants, isolation valves, and cathodic protection, as well as roadway restoration requiring historically designated brick paver replacement in the historic district and asphalt restoration elsewhere. The SOQ submission deadline was August 11, 2026 at 2:00 p.m. EST, with the subsequent RFP anticipated in mid to late August 2026. Work is expected to commence in the first quarter of 2027. Four firms have been determined as qualified to bid on the future RFP: CWA Environmental Services LLC (dba CWA Enterprises), Development of Central Florida, Ferreira Construction Co Inc., and Haugland Energy Group, LLC.
The total project estimate is $25 million. OUC seeks a single prime contractor with minimum qualifications including seven years in business, Florida licensure, $30 million bonding capacity, three or more similar projects as lead prime within the past seven years, an OSHA Experience Modification Rate of 1.0 or less, and project managers and superintendents with seven years' experience on similar projects. Insurance requirements include General Liability ($5 million), Auto Liability ($1 million with MCS-90), statutory Workers' Compensation, and Pollution Liability ($5 million). Firms with primary electrical transmission expertise may engage OUC-preapproved water main subcontractors or their own approved subcontractors, provided the prime contractor maintains all coordination responsibility.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ORLANDO UTILITIES COMMISSION
100 West Anderson Street l PO Box 3193 l Orlando, FL 32801 l 407-434-4048 Telephone l 407-434-4338 Telefax l www.ouc.com
September 22, 2026
RE: Notice of Qualifications Status
SOQ26 9357 OQ Fern Creek 230kV Underground Transmission and Water Main Civil Construction Project Prequalification’s
This letter is to inform you of the results for the SOQ26 9357 OQ process.
First on behalf of OUC I would like to thank all the firms that participated in this SOQ request. We appreciate your interest in OUC's operations and encourage each responding firm to continue to pursue future opportunities with OUC.
As a result of the selection committee’s evaluations of the qualification submissions, OUC has determined the following firms as qualified to bid on the future RFP for the subject project.
Firms attaining a qualified status in alphabetical order include:
CWA Environmental Services LLC (dba CWA Enterprises)
Development of Central Florida
Ferreira Construction Co Inc.
Haugland Energy Group, LLC
Sincerely, Rob McCarty Sr. Buyer, Strategic Sourcing Supply Chain Management Orlando Utilities Commission 100 W. Anderson St., Orlando, FL 32801 O: 407.434.3101 | C: 407.376.5667 | F: 407.434.5088
File details come from the government source that posted it. Updated .