SOM Camp Grayling Building 534QACM LCP Survey Report.pdf

PDF 4 MB Posted

Attached to
511/26126. AGY; Camp Grayling - Renovate Buildings 536Q/534Q
Solicitation number
RFQ 171 260000000277 1
Issued by
Crawford County, Michigan

About this file

This is a Pre-Renovation Asbestos and Limited Lead-Containing Paint Survey Report prepared by Atlas Technical Consultants LLC for the Michigan Department of Military and Veteran Affairs regarding Building 534Q at Camp Grayling in Grayling, Michigan. The survey was conducted on February 24, 2026, by State of Michigan Certified Asbestos Inspector Andrew DeLodder to identify and collect samples of suspect asbestos-containing materials (ACMs) and lead-containing paint (LCP) prior to renovation activities at the barracks facility. The inspection involved ninety-three (93) asbestos bulk samples collected from thirty-one (31) homogeneous areas and five (5) representative paint chip samples. The survey was completed in accordance with OSHA Asbestos Construction Industry Standards (29 CFR 1926.1101) and the Asbestos Hazard and Emergency Response Act of 1987 (AHERA).

The laboratory analysis identified two (2) suspect materials containing greater than 1 percent asbestos, including a vibration dampener containing 35% Chrysotile and window glaze containing 4% Chrysotile. An additional three (3) materials contained less than 1 percent asbestos, including window glaze and caulking materials with trace to 0.75% Chrysotile content. The lead-containing paint analysis, conducted using EPA Test Method SW 846-7420 and 3050B with Flame AAS, revealed that four (4) of the five paint samples contained lead levels exceeding the laboratory reporting limits. The report recommends that any additional suspect materials discovered during renovation or demolition activities be assumed to contain asbestos until proven otherwise through sampling and analysis.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PRE-RENOVATION ASBESTOS AND LIMITED LEAD-CONTAINING PAINT SURVEY

CAMP GRAYLING: BUILDING 534Q

Camp Grayling Grayling, Michigan Project #188BS26106

PREPARED FOR:

Michigan Department of Military and Veteran Affairs

PREPARED BY:

Atlas Technical Consultants LLC 46555 Humboldt Drive, Suite 100 Novi, Michigan 48377 March 20, 2026

Page | 1

46555 Humboldt Drive, Suite 100 Novi, Michigan 48377

(248) 669-5147 | oneatlas.com

March 20, 2026

Jon Jorgensen NCARB Design Manager Michigan Department of Military and Veterans Affairs Construction & Facilities Management Office (CFMO) Reserve Forces Support Center 3423 N. Martin Luther King Jr. Blvd. #321K Lansing, MI 48906

Subject: Pre-Renovation Asbestos and Limited Lead-Containing Paint Survey Camp Grayling: Building 534Q 12950 E. Grand River Ave Brighton, MI 48116

Dear Mr. Jorgensen:

Atlas is pleased to present this report detailing the findings of the pre-renovation asbestos and limited lead-containing paint survey performed at the above referenced site. The purpose of this sampling was to identify and collect samples of suspect asbestos containing materials (ACMs) and lead-containing paint (LCP) prior to renovation activities.

The pre-demolition asbestos and limited lead-containing paint sampling was conducted on February 24, 2026, by Industrial Hygienist, Mr. Andrew DeLodder, State of Michigan certified asbestos inspector. The sampling was conducted in accordance with sampling criteria specified in the Occupational Safety and Health Administration’s (OSHA) Asbestos Construction Industry Standard (29 CFR 1926.1101), and the Asbestos Hazard and Emergency Response Act of 1987

(AHERA).

If you have any questions, please call us at 248.669.5140.

Respectfully submitted, Kandy Rauser Project Manager Atlas Technical Consultants LLC

Page | i

CONTENTS

EXECUTIVE SUMMARY

1. INTRODUCTION

1.1 Purpose

1.2 Pre-Renovation Asbestos Survey

2. GENERAL SITE CONDITIONS

2.1 General Property and Building Information

2.2 Exterior Finish Descriptions

2.3 Interior Building Descriptions

3. PRE-RENOVATION ASBESTOS SURVEY

3.1 Homogeneous Areas

3.2 Hazard Assessment Factors

3.3 Laboratory Analytical Methodology

3.4 Sampling Results

4. LEAD-CONTAINING PAINT SAMPLING

5. CONCLUSIONS AND RECOMMENDATIONS

5.1 Asbestos Containing Materials

5.2 Lead-Containing Paint

6. ASSUMPTIONS AND LIMITATIONS

TABLES

Table 3-1 ACM Sampling Results

Table 4-1 Lead-Containing Paint Sampling Results

APPENDICES

Appendix A Sample Location Drawing and Photolog Appendix B Asbestos Laboratory Report Appendix C Lead-Containing Paint Laboratory Report

Page | 2

EXECUTIVE SUMMARY

Atlas representative Mr. Andrew DeLodder, completed the pre-renovation asbestos and limited lead-containing paint survey of building 534Q, located at Camp Grayling, in Grayling, Michigan, on February 24, 2026.

Ninety-three (93) asbestos bulk samples, taken from thirty-one (31) homogenous areas, were collected and submitted for analysis by Polarized Light Microscopy (PLM). Of the Ninety-three samples submitted, one hundred-fourteen (114) sample layers were analysed. The results of laboratory testing indicated that two

(2) of the suspect materials contained greater than 1 percent asbestos. The results of laboratory testing indicated that three (3) of the suspect materials contained less than 1 percent asbestos.

Five (5) representative sample of paint, taken from interior of the building, was collected and submitted for analysis by Flame AAS. The results of laboratory testing of the paint chip sample indicated that four (4) samples contained levels of lead greater than the laboratory reporting limits.

If any additional materials are discovered during renovation/demolition activities, such materials must be assumed to contain asbestos until sampling and analysis proves otherwise.

Page | 3

1. INTRODUCTION

1.1 Purpose

The purpose of this project was to conduct a pre-renovation asbestos and limited lead-containing paint survey of building 534 Q, located at Camp Grayling in Grayling, Michigan.

1.2 Pre-Renovation Asbestos Survey

The scope of the pre-renovation asbestos survey included the following:

• Review of existing asbestos reports for the building(s), if available;

• Survey of the property building(s);

• Identification of accessible suspect asbestos-containing materials (ACMs);

• Collection and analysis of bulk samples of suspect friable and non-friable materials.

2. GENERAL SITE CONDITIONS

2.1 General Property and Building Information

General property and building information is presented in the following table:

General Property and Building Information

Date of Inspection: February 24,2026

Inspectors Andrew DeLodder Inspector # A48677

Property Address: Camp Grayling, Grayling Michigan

Property Owner Michigan Department of Military and Veteran Affairs

Building Description: Barracks

2.2 Exterior Finish Descriptions

The exterior of the building includes CMU block walls, concrete slab foundation, and a pitched asphalt shingled roof.

2.3 Interior Building Descriptions

The interior finishes of the building included CMU block walls, wall board system ceilings and concrete floors.

3. PRE-RENOVATION ASBESTOS SURVEY

Atlas representative Mr. Andrew DeLodder conducted the pre-renovation asbestos inspection of the building

Camp Grayling on February 24,2026. Mr. DeLodder is a State of Michigan Certified Asbestos Inspector’s

(Certification No. A48677). The areas identified for renovation were visually inspected for the presence of building materials that are suspected to contain asbestos. Bulk samples of suspect ACMs were collected and placed into individual containers for transport to a National Voluntary Lab Accreditation Program

(NVLAP)-accredited laboratory for analysis. Materials typically known as non-asbestos items (i.e. fibrous glass, foam rubber, wood, etc.) were not sampled. The asbestos inspection consisted of the following three basic procedures:

> Conducting a visual inspection of the structures;

> Identifying homogeneous areas (HAs) of suspect surfacing, thermal system insulation, and miscellaneous materials; and

Page | 4

> Sampling accessible, friable and non-friable suspect materials.

3.1 Homogeneous Areas

Prior to collecting any samples, homogenous areas (HAs) were identified. A homogeneous sampling area can be described as one or more areas of material that are similar in appearance and texture and that have the same apparent installation date, appearance and function. Actual number of samples collected from each homogeneous sampling area may vary, based on the type of material and professional opinion of the inspector.

3.2 Hazard Assessment Factors

From the list of suspect homogeneous areas, a physical assessment was performed for each material on the list. A physical assessment includes evaluating the condition, assessing the potential for disturbance, and determining the friability of each material. By definition, "friable" materials are those that can be crumbled or reduced to powder by hand pressure when dry. Each material identified was further classified into one of three categories: surfacing materials, thermal systems insulation (TSI) and miscellaneous materials. Each of the three categories have specific sampling requirements, outlined below.

• Surfacing Materials: Refers to spray-applied or troweled surfaces such as plaster ceilings and walls, fireproofing, textured paints, textured plasters, and spray-applied acoustical surfaces.

• Thermal System Insulation: Refers to insulation used to inhibit heat gain or loss on pipes, boilers, tanks, ducts, and various other building components.

• Miscellaneous Materials: Refers to friable and non-friable products and materials that do not fit in any of the above two categories such as resilient floor covering, baseboards, mastics, adhesives, roofing material, caulking, glazing, and siding. This category also contains wallboard and ceiling tile.

All materials were assessed related to their condition in one of the three categories: good (intact), fair

(damaged) or poor (significantly damaged) per Title 40 Code of Federal Regulations Part 763. Material with localized, significant damage was also assessed as poor.

3.3 Laboratory Analytical Methodology

Bulk samples were analyzed by Environmental Testing Laboratories, Inc. (ETL) using polarized-light microscopy (PLM) and dispersion staining (Method Reference: 40 CFR Part 763, Volume 47, No. 103, May

27, 1982 pg. 23376). This laboratory participates in the National Voluntary Laboratory Accreditation Program

(NVLAP #201028-0), a quality assurance program for PLM analysis, and is accredited by the National Institute of Standards and Technology (NIST) as well as accreditation requirements under 15 CFR Part 25.

Copies of the laboratory analytical report and corresponding chain-of-custody forms are included in

Appendix A. Positive sample results are reported in percent asbestos by volume of the sample and the type of asbestos material within the sample. Other common non-asbestos components may also be noted on the analytical reports. Inspector and laboratory accreditations are provided in Appendix C.

3.4 Sampling Results

Bulk samples were collected from the cabin and analyzed by polarized light microscopy (PLM), EPA Method

600/R-93/116.

The following table provides a summary of accessible suspect and confirmed ACMs from the site structure:

Table 3-1 ACM Sampling Results

Sample ID/Material

Location of Materials

Material Estimated Quantity

Asbestos Content

1-CC-ABC EA 1,2,3,4 Exterior concrete - walkways 1,965 SF ND

Page | 5

Sample ID/Material

Location of Materials

Material Estimated Quantity

Asbestos Content

2-BM-ABC

EA 1,2,3,4

FS 1-10

Brick mortar - CMU block walls 11,260

SF

ND

3-EJ-ABC EA 2,4

Expansion joint - grey, in CMU block walls

80 LF ND

4-EC-ABC EA 1,2,3,4

Exterior caulk - grey, soft, around aluminum window frames(3'x4' window) and door frames

530 LF ND

5-WG-ABC EA 1,2,3,4

Window glaze - white, crumbly, aluminum windows (3'x4' window)

704 LF ND

6-EC-ABC EA 2 & FS 11

Exterior caulk - black, hard, perimeter of mechanical room door frame

20 LF ND

7-EC-ABC EA 2

Exterior caulk - grey, crumbly, natural gas penetration into wall

1 LF ND

8-EC-ABC EA 2

Exterior caulk - white, crumbly, perimeter of steel window frame

10 LF

Trace Chrysotile (PC)

9-WG-ABC EA 2

Window glaze - light grey, on steel window

12 LF

.75% Chrysotile

(PC)

10-WG-ABC EA 4

Window glaze - white, on entry door window 12 LF 4% Chrysotile

11-RM-ABC EA 5

Roofing materials, brownish red asphalt roof

8,265 SF ND

12-EC-ABC EA 5

Exterior caulk - grey, on exhaust fan

1 LF ND

13-CC-ABC FS 1-10

Concrete chip - poured concrete slab foundation

7,730 SF ND

14-EJ-ABC FS 1,3,4,6,8

Expansion joint - black, fibrous, perimeter of concrete slab foundation

580 LF ND

15-EJ-ABC FS 1,3,4,6,8,10

Expansion joint - grey, soft, seams of concrete slab foundation

290 LF ND

16-IC-ABC

FS

1,2,3,4,6,8,9,10

Interior caulk - grey, soft, perimeter of door and window frames

1030 LF ND

17-VD-ABC FS 7

Vibration dampener - black, above shower room wallboard ceiling

10 LF ND

18-VD-ABC FS 2,9

Vibration dampener - white, canvas, on air handling unit

40 SF (4

Each)

35% Chrysotile

19-EJ-ABC FS 4,6

Expansion joint - grey, hard, in

CMU block wall

20 LF ND

20-IC-ABC FS 5,6,7

Interior caulk - grey, hard, perimeter of door frame

160 LF ND

Page | 6

Sample ID/Material

Location of Materials

Material Estimated Quantity

Asbestos Content

21-IC-ABC FS 4,6

Interior caulk - white, hard, perimeter of door frame and utility sink

60 LF ND

22-WG-ABC FS 4,6

Window glaze - grey, on 3 pane door window

50 LF (2

Doors)

0.5% Chrysotile

(PC)

23-WBS-

ABC

FS 5,7

Wallboard system - bathroom ceiling

1,040 SF ND

24-PF-ABC FS 5,7

Pipe fitting - fiberglass fitting with plastic cover and brown adhesive

Fittings

ND

25-IC-ABC FS 5,7

Interior caulk - white, on ceiling/wall wood trim in shower area

250 LF ND

26-BM-ABC FS 5,7

Brick mortar - Glazed block wall

500 SF ND

27-IC-ABC FS 4,6

Interior caulk - grey, hard - in drinking fountain

2 SF ND

28-IC-ABC FS 1,3,4,6,8,10

Interior caulk - white, alligator cracking texture, on ground over expansion joint (FS-14) in front of doorways

60 LF ND

29-BM-ABC FS 11 Brick mortar - chimney stack 60 SF ND

30-TC-ABC FS 11 Terracotta - chimney liner 20 SF ND

31-SC-ABC FS 11

Stack cement - steel penetration

5 SF ND

EA=Exterior Area FS Functional Space NA=Not Applicable UNQ=Unquantified ND= None Detected

In the event additional suspect material is discovered during demolition activities, this material should be treated as presumed asbestos-containing material (PACM) in accordance with regulations 29 CFR

1926.1101 and 1910.1001 and other applicable state and local regulations and either sampled to confirm or nullify asbestos content or be treated as ACM and handled accordingly.

4. LEAD-CONTAINING PAINT SAMPLING

Atlas representative Mr. Andrew DeLodder conducted the lead-containing paint (LCP) sampling of the property building on February 24, 2026. The sampling included physical sampling of paint coatings that were deemed representative of the predominant paint coatings observed.

Five (5) paint chip sample was collected and submitted to Accurate Analytical Testing Laboratory, 30105

Beverly Road, Romulus, Michigan for lead analysis. Bulk samples were analyzed using the Environmental

Protection Agency's Test Method SW 846-7420 and 3050B using Flame AAS to determine lead concentration in percent (%) by weight. Copies of the laboratory analytical report and corresponding chain-of-custody forms are included in Appendix B. Laboratory accreditations are provided in Appendix C.

The following table provides a summary of the LCP sampling:

Page | 7

Table 4-1 Lead-Containing Paint Sampling Results

Sample ID Sample Location Color Lead

Content

Reporting Limit

1-LBP-Beige Exterior Paint on CMU block wall Beige <0.000580 0.000580

2-LBP-White Exterior paint on steel doors White 0.145 0.000500

3-LBP-Grey Interior paint on mechanical room floor Grey 0.0207 0.000566

4-LBP-White Interior paint from original 1962 building White 0.00658 0.000538

5-LBP-White Interior paint from 1977 addition White 0.00249 0.000620

5. CONCLUSIONS AND RECOMMENDATIONS

5.1 Asbestos Containing Materials

The results of laboratory testing during the pre-renovation asbestos survey conducted at the property indicate that two (2) of the materials sampled were found to contain greater than 1% asbestos. The results of laboratory testing during the pre-renovation asbestos survey conducted at the property indicate that three

(3) of the materials sampled were found to contain less than 1% asbestos.

If any additional materials are discovered during demolition/renovation activities, such materials must be assumed to contain asbestos until sampling and analysis proves otherwise.

5.2 Lead-Containing Paint

Five (5) representative sample of paint, taken from the exterior and interior of the building, were collected and submitted for analysis by Flame AAS. The results of laboratory testing during the limited lead-containing paint sampling conducted at the property indicate that four samples contained levels of lead greater than the laboratory reporting limits.

The presence of lead-containing paint requires, under OSHA 1926.62 requirements, that the contractor performing renovation, surface preparation, and other activities that impact or potentially impact the lead-coated components, evaluate potential worker exposures to airborne lead. This evaluation can be based, for the specific activities denoted in 1926.62, on objective data obtained by the contractor on other, similar, worksites within the prior calendar year. In addition, lead-containing paint and lead-coated waste and construction debris must be evaluated and, on a case-by-case basis depending on this evaluation, quantitative analysis be performed on these waste steams to ensure compliance with EPA waste disposal regulations.

The presence of Lead-Containing Paint (LCP) and/or Lead-Based Paint (LBP) does not, in itself, trigger regulatory compliance actions. However, when these materials are disturbed, the requirements of OSHA

(1926.1101) and EPA may become operative. Appropriate actions in terms of removal methods, emissions control, worker protection, and waste disposal should be considered by the general contractor and applicable subcontractors while completing renovation activities.

6. ASSUMPTIONS AND LIMITATIONS

The results, findings, conclusions, and recommendations expressed in the report are based only on conditions that were noted during the NESHAP inspections conducted on February 24, 2026, performed by

Atlas. Selection of sample locations and frequency of sampling were based on EPA Guidance documents, Page | 8

Atlas’s observations, and the assumption that building vintage and renovation history information presented to Atlas allowed the proper designation of homogenous materials for each building.

This document does not contain the elements necessary for an Abatement Work plan, and this document does not contain, nor should it take the place of technical specifications for ACM removal.

Our professional services have been performed, our findings obtained, and our conclusions and recommendations prepared in accordance with customary principles and practices in the fields of environmental science and engineering. This statement is in lieu of other statements either expressed or implied. This report does not warrant against changes to material from future operations or conditions, nor does it warrant against operations or conditions against present ACM material in locations not investigated.

The scope of services performed in execution of this evaluation may not be appropriate to satisfy the needs of other users and use or re-use of this document or the findings, conclusions, or recommendations is at the risk of said user.

APPENDIX A

SAMPLE LOCATION DRAWING AND PHOTOLOG

Asbestos / Lead-Based Paint

Sampling Location Map

Building Exterior

PROJECT NUMBER: 188BS26106

DRAWN BY: AHD REVIEWED BY Atlas

FIGURE:

DATE: 2/25/2026

4 6 5 5 5 H u m b o l d t D r i v e , S u i t e 1 0 0

N o v i , M i c h i g a n 4 8 3 7 7

P h : ( 2 4 8 ) 6 6 9 - 5 1 4 0 ~ F a x : ( 2 4 8 ) 6 6 9 - 5 1 4 7

= Asbestos Sample Number

= Lead-Based Paint Sample Location

Camp Grayling

Building # 534Q

Grayling, Michigan 49738

Map Key

EA-1

EA-2

EA-3

EA-4

EA-5

1-LBP-Beige

2-LBP-White

11-RM-A

11-RM-B

11-RM-C

12-EC-A,B,C

1-CC-A

1-CC-B

1-CC-C

2-BM-A 2-BM-B

2-BM-C

3-EJ-A

3-EJ-B

3-EJ-C

4-EC-A

4-EC-B

4-EC-C

5-WG-A

5-WG-B

5-WG-C

6-EC-A,B,C

9-WG-A,B,C

10-WG-A,B,C

Asbestos / Lead-Based Paint

Sampling Location Map

Building Interior

PROJECT NUMBER: 188BS26106

DRAWN BY: AHD REVIEWED BY Atlas

FIGURE:

DATE: 2/25/2026

4 6 5 5 5 H u m b o l d t D r i v e , S u i t e 1 0 0

N o v i , M i c h i g a n 4 8 3 7 7

P h : ( 2 4 8 ) 6 6 9 - 5 1 4 0 ~ F a x : ( 2 4 8 ) 6 6 9 - 5 1 4 7

= Asbestos Sample Number

= Lead-Based Paint Sample Location

Camp Grayling

Building # 534Q

Grayling, Michigan 49738

Map Key

FS-1

F S

-2

FS-3

FS-4

FS-8

FS-10

FS-5

FS-6

FS-7

F S

-9

FS-11

13-CC-A

13-CC-B

13-CC-C

14-EJ-A

14-EJ-B

14-EJ-C

15-EJ-A

15-EJ-B

15-EJ-C16-IC-A

16-IC-B

16-IC-C

17-VD-A,B,C

18-VD-A

18-VD-B,C

19-EJ-A,B,C

27-IC-C

22-IC-A,B

22-IC-C

21-IC-A,B,C

23-WBS-C

26-BM-A,B

26-BM-C

27-IC-A

27-IC-A

28-IC-A

28-IC-B

28-IC-C

29-BM-A,B,C

30-TC-A,B,C

31-SC-A,B,C

4-LBP-White

3-LBP-Grey

Camp Grayling

Photograph Log Building 534Q Grayling, Michigan 49738

188BS26106

Photograph #1

Homogenous Material Description

HA-1: Concrete walkways

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

1965 SF

Additional Notes

Photograph #2

HA-2: Brick mortar – CMU block walls

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

11260 SF

Photograph #3

HA-3: Expansion joint – grey, in CMU block walls

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

80 LF

Grayling, Michigan 49738

Photograph #4

HA-4: Grey caulk – perimeter of aluminum window frames, and steel door frames

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

530 LF

Photograph #5

HA-5: Window glaze

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

704 LF

Photograph #6

HA-6: Black door frame caulk

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

20 LF

Grayling, Michigan 49738

Photograph #7

HA-7: Grey caulk, on natural gas penetration

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

1 LF

Additional Notes

Very little left after sampling

Photograph #8

HA-8: White caulk, steel window frame

Asbestos Present (Yes/No/Assumed)

Yes: Trace Chrysotile

Total Quantity Present

10 LF

Photograph #9

HA-9: Window glaze – steel window

Asbestos Present (Yes/No/Assumed)

Yes: .75% Chrysotile

Total Quantity Present

12 LF

Grayling, Michigan 49738

Photograph #10

HA-10: Window glaze – white, on entry door

Asbestos Present (Yes/No/Assumed)

Yes: 4% Chrysotile

Total Quantity Present

12 LF

Photograph #11

HA-11: Asphalt roofing materials

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

8625 SF

Photograph #12

HA-12: Grey caulk on exhaust penetration

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

1 SF

Very little remains after sampling

Grayling, Michigan 49738

Photograph #13

HA-13: Concrete slab foundation

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

7730 SF

Photograph #14

HA-14: Black fibrous expansion joint

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

580 LF

Photograph #15

HA-15: Grey, soft expansion joint

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

290 LF

Grayling, Michigan 49738

Photograph #16

HA-16: Grey caulk, on door/window frames

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

1030 LF

Photograph #17

HA-17: Black vibration dampener

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

10 SF

Photograph #18

HA-18: White canvas vibration dampener

Asbestos Present (Yes/No/Assumed)

Yes: 35% Chrysotile

Total Quantity Present

40 SF

4 dampeners

Grayling, Michigan 49738

Photograph #19

HA-19: Expansion joint, grey, hard, in wall

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

20 LF

Photograph #20

HA-20: Grey caulk, hard, door frame

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

160 LF

Additional Notes

Shower and closet door frames, inside/outside

Photograph #21

HA-21: White caulk, hard, door frame

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

60 LF

Hallway bulkhead doorframe

Grayling, Michigan 49738

Photograph #22

HA-22: Window glaze – on door window

Asbestos Present (Yes/No/Assumed)

Yes: .5% Chrysotile

Total Quantity Present

50 LF (2 doors)

Additional Notes

Both shower room doors

Photograph #23

HA-23: Wallboard system

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

1040 SF

Photograph #24

HA-24: Pipe fitting

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

112 Fittings

Grayling, Michigan 49738

Photograph #25

HA-25: White caulk on ceiling trim

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

250 LF

Photograph #26

HA-26: Glazed block mortar

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

500 SF

Photograph #27

HA-27: grey caulk, inside drinking fountain

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

2 LF

Grayling, Michigan 49738

Photograph #28

HA-28: White caulk on ground

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

60 LF

Photograph #29

HA-29: Chimney stack brick mortar

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

60 SF

Photograph #30

HA-30: Terracotta chimney liner

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

20 SF

Grayling, Michigan 49738

Photograph #31

HA-31: Stack cement

Asbestos Present (Yes/No/Assumed)

No

Total Quantity Present

5 SF

APPENDIX B

ASBESTOS LABORATORY REPORT

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive Romulus, Michigan 48174

(734) 955-6600

Fax: (734) 955-6604

To:

Attention:

Atlas - Novi

46555 Humboldt Dr. Suite 100

Novi, Michigan 48377

Project Location:

Camp Grayling

Building 534Q

Client Project: 188BS26106

288777ETL Job:

Jennifer Fashbaugh

Report Issued: 03/10/2026

Lab Sample Number Client Sample Number Sample Type CompletedSampled Analyst

1867452 Asbestos1-CC-A 03/09/2026 James Farinas02/24/2026

1867453 Asbestos1-CC-B 03/09/2026 James Farinas02/24/2026

1867454 Asbestos1-CC-C 03/09/2026 James Farinas02/24/2026

1867455 Asbestos2-BM-A 03/09/2026 James Farinas02/24/2026

1867456 Asbestos2-BM-B 03/09/2026 James Farinas02/24/2026

1867457 Asbestos2-BM-C 03/09/2026 James Farinas02/24/2026

1867458 Asbestos3-EJ-A 03/09/2026 James Farinas02/24/2026

1867459 Asbestos3-EJ-B 03/09/2026 James Farinas02/24/2026

1867460 Asbestos3-EJ-C 03/09/2026 James Farinas02/24/2026

1867461 Asbestos4-EC-A 03/09/2026 James Farinas02/24/2026

1867462 Asbestos4-EC-B 03/09/2026 James Farinas02/24/2026

1867463 Asbestos4-EC-C 03/09/2026 James Farinas02/24/2026

1867464 Asbestos5-WG-A 03/09/2026 James Farinas02/24/2026

1867465 Asbestos5-WG-B 03/09/2026 James Farinas02/24/2026

1867466 Asbestos5-WG-C 03/09/2026 James Farinas02/24/2026

1867467 Asbestos6-EC-A 03/09/2026 James Farinas02/24/2026

This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this information in error, please notify ETL immediately. Thank you.

Lab Sample Number Client Sample Number Sample Type CompletedSampled Analyst

1867468 Asbestos6-EC-B 03/09/2026 James Farinas02/24/2026

1867469 Asbestos6-EC-C 03/09/2026 James Farinas02/24/2026

1867470 Asbestos7-EC-A 03/09/2026 James Farinas02/24/2026

1867471 Asbestos7-EC-B 03/09/2026 James Farinas02/24/2026

1867472 Asbestos7-EC-C 03/09/2026 James Farinas02/24/2026

1867473 Asbestos8-EC-A 03/10/2026 Teagan Murphy02/24/2026

1867474 Asbestos8-EC-B 03/10/2026 Teagan Murphy02/24/2026

1867475 Asbestos8-EC-C 03/10/2026 Teagan Murphy02/24/2026

1867476 Asbestos9-WG-A 03/10/2026 Teagan Murphy02/24/2026

1867477 Asbestos9-WG-B 03/10/2026 Teagan Murphy02/24/2026

1867478 Asbestos9-WG-C 03/10/2026 Teagan Murphy02/24/2026

1867479 Asbestos10-WG-A 03/10/2026 Teagan Murphy02/24/2026

1867480 Asbestos10-WG-B 03/10/2026 Teagan Murphy02/24/2026

1867481 Asbestos10-WG-C 03/10/2026 Teagan Murphy02/24/2026

1867482 Asbestos11-RM-A 03/10/2026 Erica Marcos02/24/2026

1867483 Asbestos11-RM-B 03/10/2026 Erica Marcos02/24/2026

1867484 Asbestos11-RM-C 03/10/2026 Erica Marcos02/24/2026

1867485 Asbestos12-EC-A 03/10/2026 Erica Marcos02/24/2026

1867486 Asbestos12-EC-B 03/10/2026 Erica Marcos02/24/2026

1867487 Asbestos12-EC-C 03/10/2026 Erica Marcos02/24/2026

1867488 Asbestos13-CC-A 03/10/2026 Erica Marcos02/24/2026

1867489 Asbestos13-CC-B 03/10/2026 Erica Marcos02/24/2026

1867490 Asbestos13-CC-C 03/10/2026 Erica Marcos02/24/2026

1867491 Asbestos14-EJ-A 03/10/2026 Erica Marcos02/24/2026

1867492 Asbestos14-EJ-B 03/10/2026 Erica Marcos02/24/2026

1867493 Asbestos14-EJ-C 03/10/2026 Erica Marcos02/24/2026

This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this

1867494 Asbestos15-EJ-A 03/10/2026 Erica Marcos02/24/2026

1867495 Asbestos15-EJ-B 03/10/2026 Erica Marcos02/24/2026

1867496 Asbestos15-EJ-C 03/10/2026 Erica Marcos02/24/2026

1867497 Asbestos16-IC-A 03/10/2026 Asha Davidson02/24/2026

1867498 Asbestos16-IC-B 03/10/2026 Asha Davidson02/24/2026

1867499 Asbestos16-IC-C 03/10/2026 Asha Davidson02/24/2026

1867500 Asbestos17-VD-A 03/10/2026 Asha Davidson02/24/2026

1867501 Asbestos17-VD-B 03/10/2026 Asha Davidson02/24/2026

1867502 Asbestos17-VD-C 03/10/2026 Asha Davidson02/24/2026

1867503 Asbestos18-VD-A 03/10/2026 Asha Davidson02/24/2026

1867504 Asbestos18-VD-B 03/10/2026 Asha Davidson02/24/2026

1867505 Asbestos18-VD-C 03/10/2026 Asha Davidson02/24/2026

1867506 Asbestos19-EJ-A 03/10/2026 Asha Davidson02/24/2026

1867507 Asbestos19-EJ-B 03/10/2026 Asha Davidson02/24/2026

1867508 Asbestos19-EJ-C 03/10/2026 Asha Davidson02/24/2026

1867509 Asbestos20-IC-A 03/10/2026 Asha Davidson02/24/2026

1867510 Asbestos20-IC-B 03/10/2026 Asha Davidson02/24/2026

1867511 Asbestos20-IC-C 03/10/2026 Asha Davidson02/24/2026

1867512 Asbestos21-IC-A 03/10/2026 Teagan Murphy02/24/2026

1867513 Asbestos21-IC-B 03/10/2026 Teagan Murphy02/24/2026

1867514 Asbestos21-IC-C 03/10/2026 Teagan Murphy02/24/2026

1867515 Asbestos22-WG-A 03/10/2026 Teagan Murphy02/24/2026

1867516 Asbestos22-WG-B 03/10/2026 Teagan Murphy02/24/2026

1867517 Asbestos22-WG-C 03/10/2026 Teagan Murphy02/24/2026

1867518 Asbestos23-WBS-A 03/10/2026 Teagan Murphy02/24/2026

1867519 Asbestos23-WBS-B 03/10/2026 Teagan Murphy02/24/2026

This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this

1867520 Asbestos23-WBS-C 03/10/2026 Teagan Murphy02/24/2026

1867521 Asbestos24-PF-A 03/10/2026 Teagan Murphy02/24/2026

1867522 Asbestos24-PF-B 03/10/2026 Teagan Murphy02/24/2026

1867523 Asbestos24-PF-C 03/10/2026 Teagan Murphy02/24/2026

1867524 Asbestos25-IC-A 03/10/2026 Teagan Murphy02/24/2026

1867525 Asbestos25-IC-B 03/10/2026 Teagan Murphy02/24/2026

1867526 Asbestos25-IC-C 03/10/2026 Teagan Murphy02/24/2026

1867527 Asbestos26-BM-A 03/10/2026 Asha Davidson02/24/2026

1867528 Asbestos26-BM-B 03/10/2026 Asha Davidson02/24/2026

1867529 Asbestos26-BM-C 03/10/2026 Asha Davidson02/24/2026

1867530 Asbestos27-IC-A 03/10/2026 Asha Davidson02/24/2026

1867531 Asbestos27-IC-B 03/10/2026 Asha Davidson02/24/2026

1867532 Asbestos27-IC-C 03/10/2026 Asha Davidson02/24/2026

1867533 Asbestos28-IC-A 03/10/2026 Asha Davidson02/24/2026

1867534 Asbestos28-IC-B 03/10/2026 Asha Davidson02/24/2026

1867535 Asbestos28-IC-C 03/10/2026 Asha Davidson02/24/2026

1867536 Asbestos29-BM-A 03/10/2026 Asha Davidson02/24/2026

1867537 Asbestos29-BM-B 03/10/2026 Asha Davidson02/24/2026

1867538 Asbestos29-BM-C 03/10/2026 Asha Davidson02/24/2026

1867539 Asbestos30-TC-A 03/10/2026 Asha Davidson02/24/2026

1867540 Asbestos30-TC-B 03/10/2026 Asha Davidson02/24/2026

1867541 Asbestos30-TC-C 03/10/2026 Asha Davidson02/24/2026

1867542 Asbestos31-SC-A 03/10/2026 Asha Davidson02/24/2026

1867543 Asbestos31-SC-B 03/10/2026 Asha Davidson02/24/2026

1867544 Asbestos31-SC-C 03/10/2026 Asha Davidson02/24/2026

This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this

Reviewed by:

Summary

Sample Layer MasticMethod

PLM 102 3

Point Count 9

Dawson Bradley

This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this

Certificate of Analysis

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Novi,Michigan 48377

Atlas - Novi

46555 Humboldt Dr. Suite 100

Camp Grayling

Building 534Q

ETL Job :

Client Project :

288777

188BS26106

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

02/24/2026

03/05/2026

Date Collected :

Date Received :

PLM None Detected 1867452

1-CC-A

PLM 99% OtherPLM 1% CelluloseGreyExterior Concrete

Non-Fibrous

Homogenous Layer-1 Analyst: James Farinas

Date Analyzed : 03/09/2026

PLM None Detected 1867453

1-CC-B

PLM 99% OtherPLM 1% CelluloseGreyExterior Concrete

Non-Fibrous

Homogenous Layer-1 Analyst: James Farinas

Date Analyzed : 03/09/2026

PLM None Detected 1867454

1-CC-C

PLM 99% OtherPLM 1% CelluloseGreyExterior Concrete

Non-Fibrous

Homogenous Layer-1 Analyst: James Farinas

Date Analyzed : 03/09/2026

PLM None Detected 1867455

2-BM-A

PLM 99% OtherPLM 1% CelluloseGreyBrick Mortar

Non-Fibrous

Homogenous Layer-1 Analyst: James Farinas

Date Analyzed : 03/09/2026

PLM None Detected 1867456

2-BM-B

PLM 99% OtherPLM 1% CelluloseGreyBrick Mortar

Non-Fibrous

Homogenous Layer-1 Analyst: James Farinas

Date Analyzed : 03/09/2026

PLM None Detected 1867457

2-BM-C

PLM 99% OtherPLM 1% CelluloseGreyBrick Mortar

Non-Fibrous

Homogenous Layer-1 Analyst: James Farinas

Date Analyzed : 03/09/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Novi,Michigan 48377

Atlas - Novi

46555 Humboldt Dr. Suite 100

Camp Grayling

Building 534Q

ETL Job :

Client Project :

288777

188BS26106

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

02/24/2026

03/05/2026

Date Collected :

Date Received :

PLM None Detected 1867458

3-EJ-A

PLM 99% OtherPLM 1% CelluloseGreyExpansion Joint

Non-Fibrous

Homogenous Layer-1 Analyst: James Farinas

Date Analyzed : 03/09/2026

PLM None Detected 1867459

3-EJ-B

PLM 99% OtherPLM 1% CelluloseGreyExpansion Joint

Non-Fibrous

Homogenous Layer-1 Analyst: James Farinas

Date Analyzed : 03/09/2026

PLM None Detected 1867460

3-EJ-C

PLM 99% OtherPLM 1% CelluloseGreyExpansion Joint

Non-Fibrous

Homogenous Layer-1 Analyst: James Farinas

Date Analyzed : 03/09/2026

PLM None Detected 1867461

4-EC-A

PLM 99% OtherPLM 1% CelluloseGreyExterior Caulk

Non-Fibrous

Homogenous Layer-1 Analyst: James Farinas

Date Analyzed : 03/09/2026

PLM None Detected 1867462

4-EC-B

PLM 99% OtherPLM 1% CelluloseGreyExterior Caulk

Non-Fibrous

Homogenous Layer-1 Analyst: James Farinas

Date Analyzed : 03/09/2026

PLM None Detected 1867463

4-EC-C

PLM 99% OtherPLM 1% CelluloseGreyExterior Caulk

Non-Fibrous

Homogenous Layer-1 Analyst: James Farinas

Date Analyzed : 03/09/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Novi,Michigan 48377

Atlas - Novi

46555 Humboldt Dr. Suite 100

Camp Grayling

Building 534Q

ETL Job :

Client Project :

288777

188BS26106

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

02/24/2026

03/05/2026

Date Collected :

Date Received :

PLM None Detected 1867464

5-WG-A

PLM 99% OtherPLM 1% CelluloseWhiteWindow Glaze

Non-Fibrous

Homogenous Layer-1 Analyst: James Farinas

Date Analyzed : 03/09/2026

PLM None Detected 1867465

5-WG-B

PLM 99% OtherPLM 1% CelluloseWhiteWindow Glaze

Non-Fibrous

Homogenous Layer-1 Analyst: James Farinas

Date Analyzed : 03/09/2026

PLM None Detected 1867466

5-WG-C

PLM 99% OtherPLM 1% CelluloseWhiteWindow Glaze

Non-Fibrous

Homogenous Layer-1 Analyst: James Farinas

Date Analyzed : 03/09/2026

PLM None Detected 1867467

6-EC-A

PLM 99% OtherPLM 1% CelluloseBlack/WhiteExterior Caulk

Non-Fibrous

Homogenous Layer-1 Analyst: James Farinas

Date Analyzed : 03/09/2026

PLM None Detected 1867468

6-EC-B

PLM 99% OtherPLM 1% CelluloseBlack/WhiteExterior Caulk

Non-Fibrous

Homogenous Layer-1 Analyst: James Farinas

Date Analyzed : 03/09/2026

PLM None Detected 1867469

6-EC-C

PLM 99% OtherPLM 1% CelluloseBlack/WhiteExterior Caulk

Non-Fibrous

Homogenous Layer-1 Analyst: James Farinas

Date Analyzed : 03/09/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Novi,Michigan 48377

Atlas - Novi

46555 Humboldt Dr. Suite 100

Camp Grayling

Building 534Q

ETL Job :

Client Project :

288777

188BS26106

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

02/24/2026

03/05/2026

Date Collected :

Date Received :

PLM None Detected 1867470

7-EC-A

PLM 99% OtherPLM 1% CelluloseGreyExterior Caulk

Non-Fibrous

Homogenous Layer-1 Analyst: James Farinas

Date Analyzed : 03/09/2026

PLM None Detected 1867471

7-EC-B

PLM 99% OtherPLM 1% CelluloseGrey/WhiteExterior Caulk

Non-Fibrous

Homogenous Layer-1 Analyst: James Farinas

Date Analyzed : 03/09/2026

PLM None Detected 1867472

7-EC-C

PLM 99% OtherPLM 1% CelluloseGreyExterior Caulk

Non-Fibrous

Homogenous Layer-1 Analyst: James Farinas

Date Analyzed : 03/09/2026

PC Trace Chrysotile1867473

8-EC-A

PC 99.75% OtherPC 0.25% CelluloseWhiteExterior Caulk

Non-Fibrous

Homogenous Layer-1 Analyst: Teagan Murphy

Date Analyzed : 03/10/2026

PC Trace Chrysotile1867474

8-EC-B

PC 99.5% OtherPC 0.5% CelluloseWhiteExterior Caulk

Non-Fibrous

Homogenous Layer-1 Analyst: Teagan Murphy

Date Analyzed : 03/10/2026

PC Trace Chrysotile1867475

8-EC-C

PC 99.75% OtherPC 0.25% CelluloseWhiteExterior Caulk

Non-Fibrous

Homogenous Layer-1 Analyst: Teagan Murphy

Date Analyzed : 03/10/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Novi,Michigan 48377

Atlas - Novi

46555 Humboldt Dr. Suite 100

Camp Grayling

Building 534Q

ETL Job :

Client Project :

288777

188BS26106

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

02/24/2026

03/05/2026

Date Collected :

Date Received :

PC 0.75% Chrysotile1867476

9-WG-A

PC 99% OtherPC 0.25% CelluloseLight GreyWindow Glaze

Non-Fibrous

Homogenous Layer-1 Analyst: Teagan Murphy

Date Analyzed : 03/10/2026

PLM None Detected 1867476

9-WG-A

PLM 100% OtherPLM Trace CelluloseWhiteBrittle Material

Non-Fibrous

Homogenous Layer-2 Analyst: Teagan Murphy

Date Analyzed : 03/10/2026

PC Trace Chrysotile1867477

9-WG-B

PC 99.75% OtherPC 0.25% CelluloseLight GreyWindow Glaze

Non-Fibrous

Homogenous Layer-1 Analyst: Teagan Murphy

Date Analyzed : 03/10/2026

PLM None Detected 1867477

9-WG-B

PLM 100% OtherPLM Trace CelluloseWhiteBrittle Material

Non-Fibrous

Homogenous Layer-2 Analyst: Teagan Murphy

Date Analyzed : 03/10/2026

PC Trace Chrysotile1867478

9-WG-C

PC 100% OtherLight GreyWindow Glaze

Non-Fibrous

Homogenous Layer-1 Analyst: Teagan Murphy

Date Analyzed : 03/10/2026

PLM None Detected 1867478

9-WG-C

PLM 100% OtherPLM Trace CelluloseWhiteBrittle Material

Non-Fibrous

Homogenous Layer-2 Analyst: Teagan Murphy

Date Analyzed : 03/10/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Novi,Michigan 48377

Atlas - Novi

46555 Humboldt Dr. Suite 100

Camp Grayling

Building 534Q

ETL Job :

Client Project :

288777

188BS26106

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

02/24/2026

03/05/2026

Date Collected :

Date Received :

PLM 4% Chrysotile1867479

10-WG-A

PLM 96% OtherPLM Trace CelluloseWhiteWindow Glaze

Non-Fibrous

Homogenous Layer-1 Analyst: Teagan Murphy

Date Analyzed : 03/10/2026

1867480

10-WG-B

Positive Stop

Layer-1 Analyst: Teagan Murphy

Date Analyzed : 03/10/2026

Layer Not Analyzed

1867481

10-WG-C

Positive Stop

Layer-1 Analyst: Teagan Murphy

Date Analyzed : 03/10/2026

Layer Not Analyzed

PLM None Detected 1867482

11-RM-A

PLM 100% OtherPLM Trace Cellulose

PLM Trace Fiberglass

Brownish RedRoofing Materials

Non-Fibrous

Homogenous Layer-1 Analyst: Erica Marcos

Date Analyzed : 03/10/2026

PLM None Detected 1867482

11-RM-A

PLM 100% OtherPLM Trace CelluloseBlackAsphaltic Material

Non-Fibrous

Homogenous Layer-2 Analyst: Erica Marcos

Date Analyzed : 03/10/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.

Polarized Light Microscopy Asbestos Analysis Report

Location :

To :

Novi,Michigan 48377

Atlas - Novi

46555 Humboldt Dr. Suite 100

Camp Grayling

Building 534Q

ETL Job :

Client Project :

288777

188BS26106

Environmental Testing Laboratories, Inc.

37575 W Huron River Drive

Romulus, Michigan 48174

(734) 955-6600, Fax: (734) 955-6604

Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos

02/24/2026

03/05/2026

Date Collected :

Date Received :

PLM None Detected 1867483

11-RM-B

PLM 100% OtherPLM Trace Cellulose

PLM Trace Fiberglass

Brownish RedRoofing Materials

Non-Fibrous

Homogenous Layer-1 Analyst: Erica Marcos

Date Analyzed : 03/10/2026

PLM None Detected 1867483

11-RM-B

PLM 100% OtherPLM Trace CelluloseBlackAsphaltic Material

Non-Fibrous

Homogenous Layer-2 Analyst: Erica Marcos

Date Analyzed : 03/10/2026

PLM None Detected 1867484

11-RM-C

PLM 100% OtherPLM Trace Cellulose

PLM Trace Fiberglass

Brownish RedRoofing Materials

Non-Fibrous

Homogenous Layer-1 Analyst: Erica Marcos

Date Analyzed : 03/10/2026

PLM None Detected 1867484

11-RM-C

PLM 100% OtherPLM Trace CelluloseBlackAsphaltic Material

Non-Fibrous

Homogenous Layer-2 Analyst: Erica Marcos

Date Analyzed : 03/10/2026

PLM None Detected 1867485

12-EC-A

PLM 100% OtherPLM Trace CelluloseGreyExterior Caulk

Non-Fibrous

Homogenous Layer-1 Analyst: Erica Marcos

Date Analyzed : 03/10/2026

PLM None Detected 1867486

12-EC-B

PLM 100% OtherPLM Trace CelluloseGreyExterior Caulk

Non-Fibrous

Homogenous Layer-1 Analyst: Erica Marcos

Date Analyzed : 03/10/2026

ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any

PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM).

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .