26B1516001 RENOVATE BUILDINGS 536Q+534Q DRAWINGS PART 4.pdf

PDF 1 MB Posted

Attached to
511/26126. AGY; Camp Grayling - Renovate Buildings 536Q/534Q
Solicitation number
RFQ 171 260000000277 1
Issued by
Crawford County, Michigan

About this file

Project Summary

This file contains electrical construction drawings (Part 4) for the renovation of Buildings 536Q and 534Q at Camp Grayling Joint Maneuver Training Center in Grayling, Michigan, prepared by the Michigan Department of Military and Veterans Affairs, Design and Construction Division. The project involves comprehensive electrical system upgrades including demolition of existing electrical infrastructure, installation of new electrical distribution panels (MDP), lighting systems with occupancy sensors, fire alarm systems, data/communications networks, and HVAC equipment controls. The scope encompasses interior electrical work across multiple rooms, exterior site power distribution, and communications infrastructure. The base bid incorporates both buildings 536Q and 534Q; however, if pricing exceeds budget constraints, Building 534Q may be dropped as a deductive alternate, requiring bidders to account for this possibility in their quantity takeoffs. The contract documents indicate an April 2026 project completion date, and all work must comply with the National Electrical Code and applicable Michigan state and local electrical codes.

The project requires coordination across multiple trades including mechanical systems, fire protection, and structural work, with the general contractor responsible for site verification prior to bidding, ensuring all subcontractors receive complete contract documents, and maintaining an on-site representative during construction with approved shop drawings. Key requirements include installation of new underground electrical feeders from switchboard P-538, new data cabling terminating in a communications server rack, fire alarm system integration with remote monitoring capability, and disconnection and removal of existing underground electrical feeders. The contractor must contact utilities at least 72 hours before excavation work (reference Mr. C.G. Michael Halcomb at 989-344-6184). All electrical conduit must transition from PVC to galvanized rigid metal conduit when crossing concrete slabs or transitioning from below-grade to above-grade locations, and all exposed conduit must be painted to match adjacent wall and ceiling finishes.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

R ss ss s s s s ss ss s s s ss s s sss ss ss s s

3 3 ss s ss s s

7 7

3 3

DATA/TELEPHONE SYSTEM OUTLET, WALL MOUNTED

TELEPHONE TERMINAL CABINET

ELECTRICAL DISTRIBUTION PANEL

ELECTRICAL LIGHTING PANEL

IN A SINGLE GANG DEVICE BOX

ELECTRICAL LEGEND

LIGHTING CONTACTOR

FOUR WAY SWITCH

THREE WAY SWITCH

ELECTRIC MOTOR

DISCONNECT SWITCH

COMBINATION MAGNETIC MOTOR STARTER

MAGNETIC MOTOR STARTER

TWO POLE SWITCH

A

C

S SINGLE POLE SWITCH

EXIT LIGHT, WALL MOUNTED

EXIT LIGHT, CEILING MOUNTED

LETTER INDICATES TYPE

HOMERUN TO LIGHTING, RECEPTACLE OR POWER PANEL

CONDUIT AND WIRE CONCEALED IN CEILING OR WALL

SPECIAL RECEPTACLE 250V. 2P-3WIRE GROUNDING TYPE

DUPLEX CONVENIENCE RECEPTACLE WITH GROUND

DUPLEX RECEPTACLE 20A. 125V. 2 POLE 3 WIRE

LED LIGHT FIXTURE, LETTER INDICATES TYPE

WALL MOUNTED LIGHTING FIXTURE

DUPLEX CONVENIENCE RECEPTACLE WITH GFI

ACT

MANUAL MOTOR STARTER WITH THERMAL OVERLOADS

T

BUSSMAN "FUSESTAT" BOXCOVER WITH SWITCH

EMERGENCY OFF PUSHBUTTON STATION,

MOUNT ABOVE COUNTER TOPACT

ABOVE FINISH FLOORAFF

S

S

S

S & SCREW-IN FUSE SIZED FOR LOAD

FAULT PROTECTION

GROUNDING TYPE

PROTECTION; ABOVE COUNTER TOP

REFER TO SPECIFICATION

C

LETTER INDICATES TYPE

CEILING MOUNTED LIGHTING FIXTURE

D

EP

AR

TM

EN

T

O F

M

IL

IT

AR

Y

AN

D V

ET

ER

AN

S

AF

FA

IR

S

ST

AT

E O

F M

IC

H

IG

AN

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

B1

E-

JU

L

AP

R

R

EN

O

VA

TE

B

U

IL

D

IN

G

Q

/5

Q C

AM

P

G R

AY

LI

N G

J O

IN

T

M

AN

EU

VE

R T

R

AI

N

IN

G C

EN

TE

G

AY

LI

N G

, M

IC

H

IG

AN

E-1

UTILITIES

989-344-6184

72 HOURS

(3 WORKING DAYS)

CALL Mr. Halcomb

BEFORE YOU DIGC.G.

MICHAEL HALCOMB

CAMP GRAYLING ENGINEERING

KAB'17

KNOW WHAT'S BELOW.

CALL BEFORE YOU DIG.

ALL DETAILS WITHIN ARE FOR BOTH BUILDING 536Q AND

BUILDING 534Q UNLESS OTHERWISE NOTED.

UNLESS OTHERWISE NOTED, SCHEDULES SHOWN ARE FOR 1

EACH BUILDING; CONTRACTOR SHALL BE RESPONSIBLE FOR

THE QUANTITIES NEEDED AND REQUIRED IF BOTH BUILDINGS

536Q AND 534Q ARE REMODELED.

ALL DETAILS WITHIN ARE FOR BOTH BUILDING 536Q AND BUILDING 534Q

UNLESS OTHERWISE NOTED. BASE BID INCORPORATES BOTH BUILDINGS

536Q & 534Q. CONTRACTOR SHALL BE RESPONSIBLE FOR THE

QUANTITIES NEEDED AND REQUIRED IF BOTH BUILDINGS 536Q AND 534Q

ARE REMODELED. IF PRICING IS TOO HIGH, BUILDING 534Q WILL BE

DROPPED FROM THE CONTRACT (DEDUCTIVE ALTERNATE) SO BIDDING

CONTRACTORs NEED TO DO THEIR TAKE-OFFs WITH THIS IN MIND.

ELECTRICAL FIRST FLOOR DEMOLITION PLAN

SCALE 1/8" = 1'-0"

ELECTRICAL DEMOLITION KEY NOTES X :

1. APPROXIMATE UNDERGROUND ROUTE OF BUILDING PANEL FEEDER. CONTRACTOR

SHALL DISCONNECT FEEDER, REMOVE FROM BUILDING AND OUTSIDE WALL, CUT

CONDUIT AND WIRE BELOW GRADE AND ABANDON IN PLACE. PATCH HOLES IN

MASONRY WALLS AND FLOOR WITH EPOXY GROUT.

2. EXISTING UNDERGROUND FEEDER BETWEEN BUILDING 536Q AND EXISTING

SWITCHBOARD P-538 IS ROUTED ON THE NORTH SIDE OF THE SAND DRIVE AND

PARALLEL WITH THE BUILDINGS UNTIL IT IS DIRECTLY NORTH OF P-538. IT THEN CUTS

DIRECTLY SOUTH, UNDERGROUND TO P-538.

3. REMOVE EXISTING EXTERIOR LIGHTING FIXTURES. PATCH HOLES IN MASONRY WALLS

AND FLOOR WITH EPOXY GROUT.

4. REMOVE EXISTING CONDUIT, WIRE, RECEPTACLES, DEVICES AND BOXES IN THIS ROOM.

REMOVE LIGHTING FIXTURES, SWITCHES AND SWITCH BOXES. ALL CIRCUITS AND

RACEWAYS SHALL BE REMOVED BACK TO THEIR SOURCE.

5. REMOVE EXISTING PANELBOARD, CONDUIT AND WIRING ONCE NEW ELECTRICAL

SYSTEM IS OPERATIONAL. PATCH ALL MASONRY HOLES WITH EPOXY GROUT IN BILLET

LOCATION.

6. DISCONNECT EXISTING EXHAUST FANS AND AIR HANDLING EQUIPMENT. REMOVE

ELECTRICAL CONDUIT AND WIRE BACK TO IT'S SOURCE. REMOVE CONTROLS

EQUIPEMENT, DEVICES, WIRING, AND CONDUIT BACK TO SOURCE.

7. EXISTING UNDERGROUND TELECOMM CABLE ROUTE. CABLE RUNS UP ALONG SIDE OF

BUILDING WALL, ENTERS THE BUILDING, AND ROUTES ALONG TO THE "COMMSCOPE

BMP" ENCLOSURE. CONTRACTOR SHALL DISCONNECT AND REMOVE THIS CABLE, COIL

IT UP OUTSIDE THE BUILDING, PROTECT IT DURING CONSTRUCTION, AND REROUTE IT

INTO THE TO THE NEW COMMUNICATIONS RACK IN FAN ROOM 103S. THE CONTRACTOR

SHALL ALSO REMOVE, SAVE, STORE, PROTECT, AND REMOUNT THE EXISTING

TELEPHONE CABLE TERMINATION "COMMSCOPE BMP" ENCLOSURE NEXT TO THE NEW

COMM RACK

**534Q EXISTING LATRINE

**THE EXISTING LATRINE FLOOR PLANS FOR 536Q

AND 534Q ARE DIFFERENT - THESE TWO PLANS

SHOW THE DIFFERENCES; THE REMAINING FLOOR

PLAN AREAS ARE THE SAME IN EACH BUILDING.**536Q EXISTING LATRINE

E-1

2 ELECTRICAL FIRST FLOOR DEMOLITION PLAN

SCALE 1/8" = 1'-0"

GENERAL ELECTRICAL CONSTRUCTION NOTES (APPLIES TO ALL

ELECTRICAL DRAWINGS & DETAILS):

1. SEAL ALL FIRE RATED WALL & CEILING PENETRATIONS WITH FIRE RATED CAULK.

2. CONNECT ALL EMERGENCY LIGHTING AND EXIT SIGNS TO LOCAL LIGHTING CIRCUITS AHEAD OF THE ROOM LIGHTING

CONTROL.

3. COORDINATE LOCATIONS OF LIGHT FIXTURES WITH ALL PIPING, DUCTWORK, AND EQUIPMENT. MOUNT LIGHT FIXTURES TO

ALLOW THE GREATEST POSSIBLE HEADROOM.

4. UNLESS OTHERWISE NOTED OR DETAILED, INSTALL ALL CONDUCTORS IN CONDUIT. THIS INCLUDES FIRE ALARM, DDC, LOW

VOLTAGE LIGHTING CONTROL WIRING, AND DATA CABLES.

5. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST ACCEPTED EDITION OF THE NATIONAL ELECTRICAL

CODE AND ALL STATE AND LOCAL CODES.

6. COORDINATE THE INSTALLATION OF ALL ELECTRICAL EQUIPMENT AND CONNECTIONS WITH ARCHITECTURAL AND

STRUCTURAL DRAWINGS.

7. "BACK TO BACK" OR THROUGH THE WALL BOXES SHALL NOT BE USED.

8. RECEPTACLES INDICATED AS GROUND FAULT CIRCUIT INTERRUPTER TYPE MAY BE EITHER GFI RECEPTACLES OR

SPECIFICATION GRADE DUPLEX RECEPTACLES CONNECTED TO A CIRCUIT PROTECTED BY A GFI CIRCUIT BREAKER.

9. PROVIDE EQUIPMENT GROUNDING CONDUCTORS IN EVERY POWER AND LIGHTING CONDUIT, ONE GROUNDING CONDUCTOR

FOR EACH CIRCUIT INCLUDING LIGHTING FIXTURE WHIPS (IF INSTALLED). ALL 120V CIRCUITS SHALL CONSIST OF AN UNGROUNDED CONDUCTOR, AN INSULATED NEUTRAL AND A GROUNDING CONDUCTOR. THERE SHALL BE NO SHARING OF

NEUTRALS.

10. ALL LIGHTING AND POWER CONDUCTORS SHALL BE 12 AWG MINIMUM.

11. MINIMUM CONDUIT SIZE SHALL BE 3/4" INTERNAL DIAMETER.

12. ARMORED CABLE TYPE AC or "BX" AND METAL CLAD TYPE MC CABLE SHALL NOT BE USED ON THIS PROJECT.

13. CONTRACTOR SHALL TRANSITION FROM PVC CONDUIT TO GALVANIZED RIGID METALLIC CONDUIT (GRC) WHEN TURNING UP

FROM BELOW A CONCRETE SLAB OR FROM BELOW GRADE TO ABOVE GRADE, WEATHER INDOORS OR OUTDOORS, BY INSTALLING A GRC NINETY DEGREE ELBOW AND THEN CONTINUING ABOVE SLAB OR GRADE UTILIZING GALVANIZED RIGID METAL CONDUIT. THIS APPLIES TO ALL RACEWAYS FOR ALL SYSTEMS INCLUDING DATA, UTILITY POWER AND/OR

EMERGENCY POWER, LIGHTING, & COMMUNICATIONS SYSTEMS.

14. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE PRIOR TO BIDDING TO VERIFY ALL EXISTING

CONDITIONS AND DIMENSIONS.

15. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR FURNISHING HIS SUBCONTRACTORS AND SUPPLIERS ALL THE NECESSARY CONTRACT DOCUMENTS TO ENSURE THEY INCLUDE ALL ITEMS IN THEIR BID THAT ARE WITHIN THEIR

DISCIPLINE.

16. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL WORK REQUIRED AND PERFORMED TO CARRY OUT THE INTENT OF

THIS PROJECT; INCLUDING THAT WORK REQUIRED AND PERFORMED BY THE SUBCONTRACTORS.

17. THE GENERAL CONTRACTOR SHALL HAVE A RESPONSIBLE REPRESENTATIVE FROM THEIR COMPANY ON SITE AT ALL TIMES DURING HIS COMPANY'S WORK, OR THE WORK OF ONE OF THE SUBCONTRACTORS. THIS REPRESENTATIVE SHALL HAVE ON SITE, HIS OWN COPY OF THE CONTRACT SPECIFICATIONS, DRAWINGS AND DMVA APPROVED SHOP DRAWINGS.

18. DISCREPANCIES FOUND BETWEEN THE SPECIFICATIONS AND THE DRAWINGS SHALL BE SUBMITTED TO DMVA IN THE FORM OF AN RFI FOR CLARIFICATION PRIOR TO ANY WORK INVOLVING THIS DISCREPANCY. ELECTRICAL DEMOLITION PLANS

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text 102N

AutoCAD SHX Text 100S

AutoCAD SHX Text 104N

AutoCAD SHX Text 102S

AutoCAD SHX Text 104S

AutoCAD SHX Text 100S

AutoCAD SHX Text

AutoCAD SHX Text 103S

AutoCAD SHX Text 100N

AutoCAD SHX Text 100N

AutoCAD SHX Text 103N

AutoCAD SHX Text 4" D.

AutoCAD SHX Text 10" D.

AutoCAD SHX Text 8" D.

AutoCAD SHX Text 8" D.

AutoCAD SHX Text 10" D.

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text 100S

AutoCAD SHX Text 100S

AutoCAD SHX Text

AutoCAD SHX Text 103S

AutoCAD SHX Text 100N

AutoCAD SHX Text 100N

AutoCAD SHX Text 103N

AutoCAD SHX Text

GFI

AutoCAD SHX Text

GFI

AutoCAD SHX Text

TUEBOR

AutoCAD SHX Text U

AutoCAD SHX Text S

AutoCAD SHX Text Q

AutoCAD SHX Text U

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text M

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text

KAB

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text M

AutoCAD SHX Text L

AutoCAD SHX Text A

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text C

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text U

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

CONSTRUCTION

AutoCAD SHX Text

FINAL RECORD

AutoCAD SHX Text

DATE

AutoCAD SHX Text

ISSUED FOR

AutoCAD SHX Text

INDEX CODE

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text

IDENTIFICATION NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

AutoCAD SHX Text

FACILITIES AND BUSINESS SERVICES ADMINISTRATION

AutoCAD SHX Text

ADAM LACH RA, DIRECTOR

AutoCAD SHX Text

JDJ

AutoCAD SHX Text

AJP

AutoCAD SHX Text

KAB

AutoCAD SHX Text

KAB

AutoCAD SHX Text N

AutoCAD SHX Text W

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text W

AutoCAD SHX Text E

AutoCAD SHX Text S

EWC

GFI, A18

ENC-2 ENC-3

J

FIRE SUPPRESSION

SYSTEM HORN &

STROBE, NOTE 11

EWC

GFI, B18

R

R

NOTES

1 & 11NOTES

1 & 11

NOTE 20 NOTE 20

MDP-19

(B-1, P-1)

MDP-21

(B-2, P-2)

JNOTES

9 & 10

NOTES

16, 21

R

R

FIRE

SUPPRESSION

EQUIPMENT

(MDP-23)

NOTES

9 & 10

EXTEND TELECOMM.

CABLING TO 103S,

REMOUNT EXISTING

TERMINATION

EQUIPMENT, INSTALL

NEW SERVER RACK AND

IT EQUIPMENT, SEE

NOTES 16, & 21

NEW HANDHOLE FOR

NEW FIBER CABLE -

REFER TO CIVIL

DRAWINGS FOR

UNDERGROUND CABLE

PATH TO HANDHOLE,

ROUTE IN ORANGE

INNERDUCT TO SERVER

RACK IN FAN ROOM 103S

NEW SERVER RACK,

SEE NOTES AND

DETAIL ON E-6

SEE

HANDHOLE

SCHEDULE

ON SHEET

E-4

DATA REQURIED FOR

FIRE ALARM PANEL

DATA REQUIRED

FOR BMS

ENCLOSURE

UNIT HEATER

FAN RUN OFF

LINE VOLTAGE

THERMOSTAT,

SEE MECH.

Future Refrig

PANEL B PANEL A

A19

A7

42" AFF 42" AFF

GFI

B11

MDP-8,10,12

AHU-2

MDP 9,11

AHU-1

ACT

GFI

Future Refrig

A19 A19

A19

A11 A11 A11 A11

A11

A7 A7

A7

A9A9 A9 A9

A9

A4

A4

A4A4A4

A2

A2A2A2A2

A8 A8

A8

A8 A6A8 A6A6

A7

A15/17 A8

A16

ACT

B15,17 B8

B13

A12

A12

GFI

42" AFF

B12

B12B12

B16

GFI

GFI

ACT

GFI

A16

ACT

GFI

A16

ACT

GFI

A16

ACT

GFI

B16

ACT

GFI

B16

ACT

GFI

B16

B7

B11 B11 B11 B19

B11

B9

B9 B9B9 B9

B7

B7 B7 B7

B6

B4

B4

B4 B4 B4

B6 B6 B8B8

B8

B2

B2

B2 B2 B2

B8 B8

A12

GFI

42" AFF

HH-A

NOTES 1 & 11

NOTES 1 & 11

NOTES 1 & 11

NOTES 1 & 11

10'-0"

NEW UNDERGROUND MDP FEEDER FROM P-538

MDP CU-1

B14 A14

B19 B19

B19

B-1

P-1

B-2

P-5

P-3

MDP-16

ENC-1

MDP 31,33

MDP-17

NOTE 17

GFI

UH-1

MDP-22

MDP-25

WP, GFI

MDP-20

MDP-26,28,30

CU-2

WP, GFI

MDP-20

P-2

NOTE 22

NOTE 22 NOTE 22

NOTE 22

P-4

FACP

P-6 MDP-15

GM-1

GFI

GFI

MDP-20

MDP-24

MDP-18

MDP-27

B5

GFI

A5

GFI

B5

MDP-16

HH-B

MDP 1,3,5MDP 2,4,6

A13

EF-1

MDP-14

EF-2

MDP-14

A5

CU

NOTE 1

CONDENSING UNIT DISCONNECT DETAIL NOTES:

1. THE BUILDING'S EXTERIOR'S SPLIT-FACE BLOCK PRESENTS AN

UNEVEN MOUNTING SURFACE, THEREFORE PROVIDE & INSTALL A

GALVANIZED U-CHANNEL RACK TO HOLD THE TWO ELECTRICAL

DISCONNECTS FOR THE CONDENSING UNITS. SIZE AS NEEDED TO

HOLD THE SWITCHES AND JUNCTION BOX.

2. CONFIGURE U-CHANNEL RACK SUCH THAT THE DISCONNECT

SWITCHES ARE 2'-0" TO BOTTOM OF SWITCH ENCLOSURE.

3. THE RACKS LOCATION SHALL BE IN FRONT OF THE TWO CONDENSING

UNITS PROVIDING THE PROPER NEC CLEARANCE SPACE.

4. ROUTE THE CONDUCTORS FROM EACH DISCONNECT TO THE

RESPECTIVE CONDENSING UNIT UTILIZING LIQUID-TITE FLEXIBLE

METAL CONDUIT.

5. BRANCH CIRCUITS FROM MDP. ROUTE UNDERSLAB THEN

UNDERGROUND FROM MDP TO THIS DISCONNECT RACK. RACEWAY

SHALL BE RIGID METAL CONDUIT WHERE EXPOSED.

6. UTILIZE STAINLESS STEEL HARDWARE TO SECURE U-CHANNEL STEEL

TO THE CONCRETE. PROVIDE AND INSTALL EXPANSION ANCHORS

INTO CONCRETE. BRACE THE RACK FROM BEHIND WITH TWO

U-CHANNEL LENGTHS AT A 45° ANGLE TO THE CONCRETE SLAB.

VERTICAL U-CHANNEL BASE PLATE SHALL BE MANUFACTURED BY THE

SAME COMPANY THAT MANUFACTURERS THE U-CHANNEL.

7. MOUNT A NEW GFI RECEPTACLE IN A WEATHERPROOF DEVICE BOX

WITH A WEATHERPROOF RECEPTACLE COVER ON THE BACKSIDE OF

THE U-CHANNEL RACK.

NOTE 5

NOTE 6

CONCRETE

SLAB -

SEE CIVIL

NOTE 7

24" BETWEEN TOP OF

CONDUITS AND UNDERSIDE

OF SLAB

Grade

NEW HANDHOLE HH-A

SIZED AS INDICATED IN

HANDHOLE SCHEDULE

ON SHEET E-4

TWO (2) 2" PVC CONDUITS

FROM THE HAND HOLE TO

THE MECHANICAL ROOM.

30° BEND UP INTO

OPEN BOTTOM

OF HANDHOLE

FIN FLOOR

TRANSITION FROM PVC TO

RIGID METAL CONDUIT

BELOW CONCRETE SLAB

MAIN

DISTRIBUTION

PANEL MDP

BOX OUT OPENING DURING

FOUNDATION POUR. COORDINATE

WITH GENERAL TRADES

R

R

MDP-19

(B-1, P-1)

MDP-21

(B-2, P-2)

R

R

FIRE

SUPPRESSION

EQUIPMENT

(MDP-23)

EXTEND TELECOMM.

CABLING TO 103S,

REMOUNT EXISTING

TERMINATION

EQUIPMENT, INSTALL

NEW SERVER RACK AND

IT EQUIPMENT, SEE

NOTES 16, & 21

NEW HANDHOLE FOR

NEW FIBER CABLE -

REFER TO CIVIL

DRAWINGS FOR

UNDERGROUND CABLE

PATH TO HANDHOLE,

ROUTE IN ORANGE

INNERDUCT TO SERVER

RACK IN FAN ROOM 103S

SEE

HANDHOLE

SCHEDULE

ON SHEET

E-4

DATA REQURIED FOR

FIRE ALARM PANEL

DATA REQUIRED

FOR BMS

ENCLOSURE

UNIT HEATER

FAN RUN OFF

LINE VOLTAGE

THERMOSTAT,

SEE MECH.

B13

HH-A

10'-0"

MDP

B-1

P-1

B-2

P-5

P-3

MDP-16

ENC-1

NOTE 17

GFI

UH-1

MDP-22

MDP-25

P-2

P-4

FACP

P-6 MDP-15

GM-1

GFI

GFI

MDP-20

MDP-24

MDP-18

MDP-27

MDP-16

HH-B

A13

DATA/TELEPHONE SYSTEM OUTLET, WALL MOUNTED

TELEPHONE TERMINAL CABINET

ELECTRICAL DISTRIBUTION PANEL

ELECTRICAL LIGHTING PANEL

IN A SINGLE GANG DEVICE BOX

ELECTRICAL LEGEND

LIGHTING CONTACTOR

FOUR WAY SWITCH

THREE WAY SWITCH

ELECTRIC MOTOR

DISCONNECT SWITCH

COMBINATION MAGNETIC MOTOR STARTER

MAGNETIC MOTOR STARTER

TWO POLE SWITCH

A

C

S SINGLE POLE SWITCH

EXIT LIGHT, WALL MOUNTED

EXIT LIGHT, CEILING MOUNTED

LETTER INDICATES TYPE

HOMERUN TO LIGHTING, RECEPTACLE OR POWER PANEL

CONDUIT AND WIRE CONCEALED IN CEILING OR WALL

SPECIAL RECEPTACLE 250V. 2P-3WIRE GROUNDING TYPE

DUPLEX CONVENIENCE RECEPTACLE WITH GROUND

DUPLEX RECEPTACLE 20A. 125V. 2 POLE 3 WIRE

LED LIGHT FIXTURE, LETTER INDICATES TYPE

WALL MOUNTED LIGHTING FIXTURE

DUPLEX CONVENIENCE RECEPTACLE WITH GFI

ACT

MANUAL MOTOR STARTER WITH THERMAL OVERLOADS

T

BUSSMAN "FUSESTAT" BOXCOVER WITH SWITCH

EMERGENCY OFF PUSHBUTTON STATION,

MOUNT ABOVE COUNTER TOPACT

ABOVE FINISH FLOORAFF

S

S

S

S & SCREW-IN FUSE SIZED FOR LOAD

FAULT PROTECTION

GROUNDING TYPE

PROTECTION; ABOVE COUNTER TOP

REFER TO SPECIFICATION

C

LETTER INDICATES TYPE

CEILING MOUNTED LIGHTING FIXTURE

RELAYR

D

EP

AR

TM

EN

T

O F

M

IL

IT

AR

Y

AN

D V

ET

ER

AN

S

AF

FA

IR

S

ST

AT

E O

F M

IC

H

IG

AN

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

B1

E-

JU

L

AP

R

EN

O

VA

TE

B

U

IL

D

IN

G

Q

/5

Q C

AM

P

G R

AY

LI

N G

J O

IN

T

M

AN

EU

VE

R T

R

AI

N

IN

G C

EN

AY

LI

N G

, M

IC

H

IG

AN

E-2

UTILITIES

989-344-6184

72 HOURS

(3 WORKING DAYS)

CALL Mr. Halcomb

BEFORE YOU DIGC.G.

MICHAEL HALCOMB

CAMP GRAYLING ENGINEERING

KAB'17

KNOW WHAT'S BELOW.

CALL BEFORE YOU DIG.

COORDINATION NOTES:

· SEE SHEET C-1 FOR SITE UTILITIES.

· 536Q & 534Q FOLLOW THE SAME FLOOR PLAN UNLESS

OTHERWISE NOTED; SITE UTILITIES,

SITE GRADING, LANDSCAPING AND SIDEWALKS MAY BE

SLIGHTLY DIFFERENT FROM BUILDING TO BUILDING; SEE

DRAWING SHEETS C-1 THRU C-3.

ELECTRICAL POWER PLAN NOTES:

1. NEW RECEPTACLE CIRCUITS SHALL BE RUN HORIZONTALLY IN SURFACE MOUNTED

RACEWAY, SECURED TO THE EXISTING BLOCK WALL WITH HALF STRAPS AND LEAD

ANCHORS, WHERE NEW INTERIOR WALL SURFACES ARE NOT CONSTRUCTED.

DEVICE BOXES SHALL BE FD TYPE CAST BOXES WITH MATCHING DEVICE COVERS.

UTILIZE COMPRESSION TYPE FITTINGS (COUPLINGS & CONNECTORS) ON THESE

RACEWAYS.

2. ALL JUNCTION BOXES IN THE ATTIC SHALL BE MOUNTED TO THE TRUSSES ABOVE

THE INSULATION LINE.

3. ATTIC ACCESS PANEL.

4. MOUNTING HEIGHT OF RECEPTACLES SHALL BE 18" ABOVE FLOOR, UNLESS NOTED

OTHERWISE.

5. NOT USED

6. PROVIDE AND INSTALL 4"x4" JUNCTION BOX AND BLANK COVER FOR CONNECTING

THE EXTERIOR LIGHTING FIXTURE CONTROL TO THE LIGHTING CONTROL RELAY.

MOUNT ON WALL ABOVE THE MAIN DISTRIBUTION PANEL MDP. PLACE AN

IDENTIFICATION PLATE INDICATING THE BOX AND RELAY ARE "EXTERIOR LIGHTING

FIXTURE CONTROL".

7. PROVIDE A CONDUIT FROM BOTTOM OF PANEL MDP DOWN THROUGH THE FLOOR

AND THROUGH THE NEW MECHANICAL ROOM FOUNDATION WALL IN THE SPECIFIED

SLEEVES (COORDINATED). EXTERIOR CONDUIT AND LB FITTINGS WILL NOT BE

ALLOWED. THE SLEEVES SHALL BE COORDINATED WITH OTHER DISCIPLINES AT

THE TIME THE FOUNDATION IS BEING BUILT.

8. ALL EXPOSED ELECTRICAL CONDUIT SHALL BE PAINTED TO MATCH THE ADJACENT

WALLS/CEILINGS FINISH COLOR.

9. ROUTE 4#14 AWG THHN, 3/4" C BETWEEN EACH CONDENSING UNIT AND IT'S

ASSOCIATED AIR HANDLING UNIT (i.e. CU-1 & AHU-1).

10.REFER TO THE CONDENSING UNIT DISCONNECT DETAIL, SHEET E-2 FOR

ELECTRICAL RACEWAY AND SWITCH PLACEMENT REQUIREMENTS.

11.COORDINATE THE HEIGHT ABOVE FINISH GRADE OF THE DEVICE BOX FOR THE FIRE

SUPPRESSION SYSTEM HORN & STROBE UNIT.

12.CONNECT THE INCOMING POWER CONDUCTOR FOR THE EXHAUST FAN TO THE

ROOM'S LIGHTING SYSTEM OCCUPANCY SENSOR'S INTERNAL RELAY SO THAT THE

FAN INDICATED COMES ON WHEN THE OCCUPANCY SENSOR SENSES MOVEMENT.

SET THE SENSOR'S TIME-OFF TO 20 MINUTES. (EF-2, EF-3)

13.CONNECT THE INCOMING POWER CONDUCTOR FOR EXHAUST FAN EF-1 TO THE

LIGHTING SYSTEM OCCUPANCY SENSORS RELAY CONTROLLING THE TYPE D & D2

LIGHTING FIXTURES IN ROOM 105S SO THAT THE FAN COMES ON WHEN THE

OCCUPANCY SENSOR SENSES MOVEMENT. SET THE SENSOR'S TIME-OFF TO 20

MINUTES. EF-1 IS INSTALLED ABOVE THE FIRE PROTECTION SYSTEM'S PIPING NEAR

THE CEILING IN MECHANICAL ROOM 107.

14.CONNECT THE INCOMING POWER CONDUCTOR FOR EXHAUST FAN EF-6 TO THE

LIGHTING SYSTEM OCCUPANCY SENSORS RELAY CONTROLLING THE TYPE D & D2

LIGHTING FIXTURES IN ROOM 105N SO THAT THE FAN COMES ON WHEN THE

OCCUPANCY SENSOR SENSES MOVEMENT. SET THE SENSOR'S TIME-OFF TO 20

MINUTES. EF-6 IS INSTALLED ABOVE BOILER B-1 NEAR THE CEILING IN MECHANICAL

ROOM 107.

15.FOR HVAC PUMPS P-3, P-4, P-5, AND P-6 PROVIDE AND INSTALL A MANUAL MOTOR

STARTER AND RIB UNIT AS DETAILED ON THIS SHEET "HVAC MOTOR STARTER

DETAIL. COORDINATE EXACT MOUNTING LOCATIONS OF THESE MOTOR STARTER

COMPONENTS WITH THE MECHANICAL TRADES.

16.REMOUNT THE EXISTING TELECOMMUNICATIONS TERMINATION/TELEPHONE CABLE

TERMINATION/FUSE ENCLOSURE NEXT TO THE NEW COMMUNICATIONS RACK ON

THE PLYWOOD BACKBOARD.

17.PROVIDE A 2-POLE BOILER EMERGENCY PUSHBUTTON TO TURN OFF BOTH BOILER

CIRCUITS WITH ONE BUTTON, 20AMP CONTACT RATING.

18.CONNECT THE INCOMING POWER CONDUCTOR FOR EXHAUST FAN EF-4 TO THE

LIGHTING SYSTEM OCCUPANCY SENSORS RELAY CONTROLLING THE TYPE D & D2

LIGHTING FIXTURES IN ROOM 205N SO THAT THE FAN COMES ON WHEN THE

OCCUPANCY SENSOR SENSES MOVEMENT. SET THE SENSOR'S TIME-OFF TO 20

MINUTES.

19.CONNECT THE INCOMING POWER CONDUCTOR FOR EXHAUST FAN EF-5 TO THE

LIGHTING SYSTEM OCCUPANCY SENSORS RELAY CONTROLLING THE TYPE D & D2

LIGHTING FIXTURES IN ROOM 205S SO THAT THE FAN COMES ON WHEN THE

OCCUPANCY SENSOR SENSES MOVEMENT. SET THE SENSOR'S TIME-OFF TO 20

MINUTES.

20. INSTALL NEW DATA RECEPTACLE. RUN CAT 6A CABLING IN CONDUIT BACK TO

PATCH PANEL IN SERVER RACK. TERMINATE, LABEL, AND TEST. PROVIDE

ADDITIONAL PATCH CABLES 1 PER DATA DROP FOR DMVA IT TO PERFORM FINAL

CONNECTIONS.

21. MOUNT THE NEW DATA RACK AND EXISTING/SAVED "COMMSCOPE BEP" TELEPHONE

ENCLOSURE ON THE NEW PLYWOOD BACKBOARD. 4' T x 3' W X 3/4" FIRE PROOF

PLYWOOD BACKBOARD. 36" AFF TO BOTTOM OF PLYWOOD.

22. NEW CEILING MOUNTED DATA RECEPTACLE FOR FUTURE WIRELESS ACCESS

POINT. RUN CAT 6A CABLING IN CONDUIT BACK TO PATCH PANEL IN SERVER RACK.

TERMINATE, LABEL, AND TEST. PROVIDE PATCH CABLES 1 PER TERMINATION FOR

DMVA IT TO PERFORM FINAL CONNECTIONS FROM PATCH PANEL TO SWITCH.

ALL DETAILS WITHIN ARE FOR BOTH BUILDING 536Q AND

BUILDING 534Q UNLESS OTHERWISE NOTED.

UNLESS OTHERWISE NOTED, SCHEDULES SHOWN ARE FOR 1

EACH BUILDING; CONTRACTOR SHALL BE RESPONSIBLE FOR

THE QUANTITIES NEEDED AND REQUIRED IF BOTH BUILDINGS

536Q AND 534Q ARE REMODELED.

HVAC MOTOR STARTER DETAIL NOTES:

1. PROVIDE AND INSTALL A MOTOR STARTER & MANUAL DISCONNECT FOR THE MECHANICAL ITEM

INDICATED ON THE DRAWINGS. STARTER SHALL BE RIB MODEL #RIBX24SBA CONNECTED TO A

MANUAL MOTOR STARTER. RIB UNIT SHALL HAVE AN ENCLOSURE AND A HAND-OFF-AUTO SELECTOR

SWITCH MOUNTED ON THE SIDE. MANUAL MOTOR STARTER SHALL BE THE OPEN TYPE AND

MOUNTED IN A 4-SQUARE BOX WITH A MUD RING.

2. RIB UNIT BY FUNCTIONAL DEVICES, INC. (PHONE 800.888.5538, WWW.FUNCTIONALDEVICES.COM).

3. MANUAL MOTOR STARTER: SQUARE D/SCHNEIDER ELECTRIC CLASS 2510 SINGLE UNIT TYPE, 16A

RATED, WITH MELTING ALLOY TYPE THERMAL OVERLOADS. THE TOGGLE SWITCH MUST HAVE A

PILOT LIGHT AND THE ABILITY TO BE LOCKED WHEN THE UNIT IS SWITCHED TO THE "OFF" POSITION.

HVAC MANUAL MOTOR STARTER DETAIL

NO SCALE

4-SQUARE BOX

RIB RELAY UNIT

MANUAL MOTOR

STARTER

PILOT LIGHT

ALL DETAILS WITHIN ARE FOR BOTH BUILDING 536Q AND BUILDING 534Q

UNLESS OTHERWISE NOTED. BASE BID INCORPORATES BOTH BUILDINGS

536Q & 534Q. CONTRACTOR SHALL BE RESPONSIBLE FOR THE

QUANTITIES NEEDED AND REQUIRED IF BOTH BUILDINGS 536Q AND 534Q

ARE REMODELED. IF PRICING IS TOO HIGH, BUILDING 534Q WILL BE

DROPPED FROM THE CONTRACT (DEDUCTIVE ALTERNATE) SO BIDDING

CONTRACTORs NEED TO DO THEIR TAKE-OFFs WITH THIS IN MIND.

ELECTRICAL FIRST FLOOR

POWER/DATA PLAN

SCALE 1/8" = 1'-0"

GENERAL ELECTRICAL CONSTRUCTION NOTES (APPLIES TO ALL

ELECTRICAL DRAWINGS & DETAILS):

1. SEAL ALL FIRE RATED WALL & CEILING PENETRATIONS WITH FIRE RATED CAULK.

2. CONNECT ALL EMERGENCY LIGHTING AND EXIT SIGNS TO LOCAL LIGHTING CIRCUITS AHEAD OF THE ROOM LIGHTING

CONTROL.

3. COORDINATE LOCATIONS OF LIGHT FIXTURES WITH ALL PIPING, DUCTWORK, AND EQUIPMENT. MOUNT LIGHT FIXTURES TO

ALLOW THE GREATEST POSSIBLE HEADROOM.

4. UNLESS OTHERWISE NOTED OR DETAILED, INSTALL ALL CONDUCTORS IN CONDUIT. THIS INCLUDES FIRE ALARM, SOUND

AND PAGING, AND DATA CABLES.

5. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST ACCEPTED EDITION OF THE NATIONAL ELECTRICAL

CODE AND ALL STATE AND LOCAL CODES.

6. COORDINATE THE INSTALLATION OF ALL ELECTRICAL EQUIPMENT AND CONNECTIONS WITH ARCHITECTURAL AND

STRUCTURAL DRAWINGS.

7. "BACK TO BACK" OR THROUGH THE WALL BOXES SHALL NOT BE USED.

8. RECEPTACLES INDICATED AS GROUND FAULT CIRCUIT INTERRUPTER TYPE MAY BE EITHER GFI RECEPTACLES OR

SPECIFICATION GRADE DUPLEX RECEPTACLES CONNECTED TO A CIRCUIT PROTECTED BY A GFI CIRCUIT BREAKER.

9. PROVIDE EQUIPMENT GROUNDING CONDUCTORS IN EVERY POWER AND LIGHTING CONDUIT, ONE GROUNDING CONDUCTOR

FOR EACH CIRCUIT INCLUDING LIGHTING FIXTURE WHIPS (IF INSTALLED). ALL 120V CIRCUITS SHALL CONSIST OF AN UNGROUNDED CONDUCTOR, AN INSULATED NEUTRAL AND A GROUNDING CONDUCTOR. THERE SHALL BE NO SHARING OF

NEUTRALS.

10. ALL LIGHTING AND POWER CONDUCTORS SHALL BE 12 AWG MINIMUM.

11. MINIMUM CONDUIT SIZE SHALL BE 3/4" INTERNAL DIAMETER.

12. ARMORED CABLE TYPE AC or "BX" AND METAL CLAD TYPE MC CABLE SHALL NOT BE USED ON THIS PROJECT.

13. CONTRACTOR SHALL TRANSITION FROM PVC CONDUIT TO GALVANIZED RIGID METALLIC CONDUIT (GRC) WHEN TURNING UP

FROM BELOW A CONCRETE SLAB OR FROM BELOW GRADE TO ABOVE GRADE, WEATHER INDOORS OR OUTDOORS, BY INSTALLING A GRC NINETY DEGREE ELBOW AND THEN CONTINUING ABOVE SLAB OR GRADE UTILIZING GALVANIZED RIGID METAL CONDUIT. THIS APPLIES TO ALL RACEWAYS FOR ALL SYSTEMS INCLUDING DATA, UTILITY POWER AND/OR

EMERGENCY POWER, LIGHTING, & COMMUNICATIONS SYSTEMS.

14. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE PRIOR TO BIDDING TO VERIFY ALL EXISTING

CONDITIONS AND DIMENSIONS.

15. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR FURNISHING HIS SUBCONTRACTORS AND SUPPLIERS ALL THE NECESSARY CONTRACT DOCUMENTS TO ENSURE THEY INCLUDE ALL ITEMS IN THEIR BID THAT ARE WITHIN THEIR

DISCIPLINE.

16. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL WORK REQUIRED AND PERFORMED TO CARRY OUT THE INTENT OF

THIS PROJECT; INCLUDING THAT WORK REQUIRED AND PERFORMED BY THE SUBCONTRACTORS.

17. THE GENERAL CONTRACTOR SHALL HAVE A RESPONSIBLE REPRESENTATIVE FROM THEIR COMPANY ON SITE AT ALL TIMES DURING HIS COMPANY'S WORK, OR THE WORK OF ONE OF THE SUBCONTRACTORS. THIS REPRESENTATIVE SHALL HAVE ON SITE, HIS OWN COPY OF THE CONTRACT SPECIFICATIONS, DRAWINGS AND DMVA APPROVED SHOP DRAWINGS.

18. DISCREPANCIES FOUND BETWEEN THE SPECIFICATIONS AND THE DRAWINGS SHALL BE SUBMITTED TO DMVA IN THE FORM

OF AN RFI FOR CLARIFICATION PRIOR TO ANY WORK INVOLVING THIS DISCREPANCY.

CONDENSING UNIT

DISCONNECT DETAIL

NOT TO SCALE

MECHANICAL ROOM WALL SECTION

SCALE 1/2 " = 1'-0"

E-2

2 ENLARGED MECHANICAL POWER PLAN

SCALE 1/4" = 1'-0"

E-2

ELECTRICAL POWER PLANS AND DETAILS

E-2

E-2

E-2

AutoCAD SHX Text 102N

AutoCAD SHX Text 100S

AutoCAD SHX Text 104N

AutoCAD SHX Text 105N

AutoCAD SHX Text

105NA

AutoCAD SHX Text 102S

AutoCAD SHX Text 104S

AutoCAD SHX Text 103S

AutoCAD SHX Text 101S

AutoCAD SHX Text 100N

AutoCAD SHX Text 105S

AutoCAD SHX Text

105SA

AutoCAD SHX Text 101N

AutoCAD SHX Text 106S

AutoCAD SHX Text 106N

AutoCAD SHX Text 103N

AutoCAD SHX Text

AutoCAD SHX Text

GFI

AutoCAD SHX Text

GFI

AutoCAD SHX Text

TUEBOR

AutoCAD SHX Text U

AutoCAD SHX Text S

AutoCAD SHX Text Q

AutoCAD SHX Text U

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text M

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text

KAB

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text M

AutoCAD SHX Text L

AutoCAD SHX Text A

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text C

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text U

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

CONSTRUCTION

AutoCAD SHX Text

FINAL RECORD

AutoCAD SHX Text

DATE

AutoCAD SHX Text

ISSUED FOR

AutoCAD SHX Text

INDEX CODE

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text

IDENTIFICATION NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

AutoCAD SHX Text

FACILITIES AND BUSINESS SERVICES ADMINISTRATION

AutoCAD SHX Text

ADAM LACH RA, DIRECTOR

AutoCAD SHX Text

JDJ

AutoCAD SHX Text

AJP

AutoCAD SHX Text

KAB

AutoCAD SHX Text

KAB

AutoCAD SHX Text N

AutoCAD SHX Text W

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text W

AutoCAD SHX Text E

Panel A

X

S 3A1 3S

X A1

S

X

A1

S3

X

X

X

3S

X

AE A

X

A

X

B1

X

X X

D

DE

JE

J

F

E S 3

E

Note 5

Note 5

A1

S

B3

B3

B3

S

B1

B1

3SPanel B

E

B BE B B BE

B

C

J

F

S

HH

HH

B1

D

DE J

JE

S

B3

B3

A3

A3

J

A3

MDP-7

A3

X A3

A X X

B3

A3

OC1

OC1

OC1

OC1

3S

B3

AE

OC1

B

BE B B BE B

B BE B B BE

B B

BE B B BE B

OC2

AEA

A

A3

A

AE

OC1

OC2

E

B3

A3

S 3

CKT MDP-13 VIA RELAY

IN MECH ROOM

MOUNT AT HEIGHT AS

INDICATED ON SHEET A2.1

CKT MDP-13 VIA

RELAY IN MECH ROOM

OC1 OC1

X

X

E

MOUNT AT HEIGHT AS

INDICATED ON SHEET A2.1

MOUNT AT HEIGHT

AS INDICATED ON

SHEET A2.1

E CKT MDP-13 VIA

RELAY IN MECH ROOM

MOUNT AT HEIGHT

AS INDICATED ON

SHEET A2.1

E

CKT MDP-13 VIA

RELAY IN MECH ROOM

MOUNT AT HEIGHT

AS INDICATED ON

SHEET A2.1

E

CKT MDP-13 VIA

RELAY IN MECH ROOM

JR

Note 8

LOW

TEMPERATURE

LIGHT

TEMPERATURE

SENSOR CONNECTED

TO THE LOW

TEMPERATURE LIGHT

MDP

CE

F

F

Note 5

Note 5 F

F

C

Note 10

ALL 'X' FIXTURES -

MDP 29

Note 5

ALL 'X' FIXTURES -

MDP 29

ALL 'X' FIXTURES -

MDP 29

FREEZE ALARM NOTES:

DESCRIPTION OF OPERATION:

PROVIDE & INSTALL ALL MATERIALS TO CONNECT THE FREEZE ALARM TO OPERATE AS FOLLOWS:

· WHEN THE TEMPERATURE REACHES THE LOW TEMP SET-POINT THE FREEZE ALARM WILL

CLOSE IT'S INTEGRAL CONTACT AND ENABLE THE LED LIGHT.

COMPONENTS:

1. FREEZE ALARM THERMOSTAT: EMERSON WHITE-ROGERS MODEL #1687-9.

2. 2 #12AWG & #12 GND ROUTED IN CONDUIT TO RED ALARM LAMP AT PEAK OF SOUTH

EXTERIOR WALL.

3. FLUSH MOUNTED DEVICE BOX WITH AN AIMABLE LAMPHOLDER : HUBBELL-BELL #5606-2.

4. LED LAMP, RED, 120VAC: PHILLIPS ORDER # BC8A19/LED/RED/ND 120V.

FREEZE ALARM & OPERATION DETAIL

NO SCALE

N

1 3

CKT. AS INDICATED

IN PANEL SCHEDULE

FREEZE ALARM

THERMOSTAT "T"

RED LED LIGHT "G" ON

EXTERIOR OF BUILDING

G

G

B22

T

T

D

EP

AR

TM

EN

T

O F

M

IL

IT

AR

Y

AN

D V

ET

ER

AN

S

AF

FA

IR

S

ST

AT

E O

F M

IC

H

IG

AN

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

B1

E-

JU

L

R

EN

O

VA

TE

B

U

IL

D

IN

G

Q

/5

Q C

AM

P

G R

AY

LI

N G

J O

IN

T

M

AN

EU

VE

R T

R

AI

N

IN

G C

EN

AY

LI

N G

, M

IC

H

IG

AN

E-3

ALL DETAILS WITHIN ARE FOR BOTH BUILDING 536Q AND

BUILDING 534Q UNLESS OTHERWISE NOTED.

UNLESS OTHERWISE NOTED, SCHEDULES SHOWN ARE FOR 1

EACH BUILDING; CONTRACTOR SHALL BE RESPONSIBLE FOR

THE QUANTITIES NEEDED AND REQUIRED IF BOTH BUILDINGS

536Q AND 534Q ARE REMODELED.

ALL DETAILS WITHIN ARE FOR BOTH BUILDING 536Q AND BUILDING 534Q

UNLESS OTHERWISE NOTED. BASE BID INCORPORATES BOTH BUILDINGS

540Q & 538Q. CONTRACTOR SHALL BE RESPONSIBLE FOR THE

QUANTITIES NEEDED AND REQUIRED IF BOTH BUILDINGS 536Q AND 534Q

ARE REMODELED. IF PRICING IS TOO HIGH, BUILDING 534Q WILL BE

DROPPED FROM THE CONTRACT (DEDUCTIVE ALTERNATE) SO BIDDING

CONTRACTORs NEED TO DO THEIR TAKE-OFFs WITH THIS IN MIND.

ELECTRICAL FIRST FLOOR LIGHTING PLAN

SCALE 1/8" = 1'-0"

LIGHTING FIXTURE SCHEDULE

MARK

A

DESCRIPTION MANUFACTURER & CAT. NO. REMARKS NOTES

LIGHTING FIXTURE SCHEDULE NOTES:

1. CONTRACTOR MAY SUBSTITUTE LIGHTING FIXTURES BY OTHER MANUFACTURERS IF EQUAL IN ALL

RESPECTS; IF NOT, PROVIDE THE FIXTURE SPECIFIED. SUBMIT SHOP DRAWINGS FOR ALL SUBSTITUTIONS.

2. PROVIDE INTERNAL FAST BLOW FUSING IN EACH FIXTURE.

3. PROVIDE WITH INTEGRAL EMERGENCY LIGHT OPTION.

1,2

D

1,2,3

LED INDUSTRIAL STRIP FIXTURE

1,2,3

C

120V OPERATION, 4000K COLOR TEMP.

WILLIAMS INDOOR

75R-4-L85-840-DIM-UNV

MOUNTING

WILLIAMS INDOOR

PTS-24-L49-835-RA-DIM-UNV

F

LED SURFACE MOUNT WET LOCATION

120V OPERATIONCHAIN-HANG 8'-0" AFF

120V OPERATION AND

BATTERY BACK-UPDE

EXTERIOR BUILDING MOUNT

HEIGHT AS NOTED

120V OPERATION, 4000K COLOR TEMP.AE LED 2'x4' SURFACE MOUNT WITH BATTERY BACKUP

WILLIAMS

SLF-4-L52-HIA-(L37)-SILVER-DIM-UNV

WALL MOUNT OVER BATHROOM MIRROR 3000K

SURFACE MOUNT TO CEILING

SURFACE MOUNT TO CEILING

WILLIAMS INDOOR

96-4-L62-840-HIAFR-(L55)-DIM-UNV SURFACE MOUNT TO CEILING

SURFACE MOUNT TO CEILING

LED 2'x4' SURFACE MOUNT

FE

LED SURFACE MOUNT WET LOCATION WITH

BATTERY BACKUP

H SURFACE MOUNT TO WALL 120V OPERATION, 3000K COLOR TEMP.

E 120V OPERATION, 5000K COLOR TEMP.

X

OCCUPANCY SENSOR SCHEDULE NOTES:

1. OCCUPANCY SENSORS MANUFACTURED BY COOPER INDUSTRIES, HUBBELL, LEVITON, SENSOR SWITCH &

LUTRON ELECTRONICS ARE ACCEPTABLE IF EQUAL IN ALL RESPECTS.

2. PROVIDE WITH LIGHTING FIXTURE CIRCUIT CONTROL RELAY (POWER PACK) AND LOW-VOLTAGE POWER SUPPLY

FOR A COMPLETE AND WORKING CONTROL SYSTEM.

3. OCCUPANCY SENSOR SHALL HAVE AN ADDITIONAL/OPTIONAL RELAY TO TURN ON/OFF EXHAUST FANS (120VAC)

OR SIGNAL THE DDC SYSTEM.

FIRST FLOOR LIGHTING PLAN NOTES:

1. ROUTE CONDUIT IN CONCEALED SPACES WHERE AVAILABLE. ALL EXPOSED

ELECTRICAL CONDUIT SHALL BE PAINTED TO MATCH THE WALLS/CEILINGS FINISH

COLOR. UTILIZE COMPRESSION FITTINGS (COUPLINGS & CONNECTORS) FOR EMT

(SET SCREW FITTINGS WILL NOT BE APPROVED.)

2. ALL JUNCTION BOXES IN THE ATTIC SHALL BE MOUNTED TO THE TRUSSES ABOVE

THE INSULATION LINE.

3. ROUTE EXTERIOR LIGHTING FIXTURE CONDUITS THRU EXISTING SPLIT FACE

BLOCK AND CONCEAL BETWEEN NEW AND EXISTING BLOCK. SURFACE MOUNTED

CONDUIT ON EXTERIOR WALLS IS NOT ALLOWED.

4. CONNECT EMERGENCY LIGHTING UNITS AND EXIT FIXTURES TO THE LIGHTING

CIRCUIT IN THAT ROOM AHEAD OF THE SWITCH. TYPICAL OF ALL ROOMS.

5. COORDINATE THE LOCATION OF EACH TYPE "F" AND "C" LIGHTING FIXTURES IN

ROOMS 103N, 103S, AND 107 WITH THE MECHANICAL TRADES.

6. CONNECT THE LIGHTING CIRCUIT TO THE ROOM EXHAUST FAN.

7. SET THE OCCUPANCY SENSORS IN THE JANITOR CLOSETS, ROOM NUMBERS 101N

& 101S TO DELAY-OFF AT 20 MINUTES.

8. EXTERIOR BUILDING MOUNTED LIGHTING CONTROL WORK: CONNECT THE

EXTERIOR LIGHTING FIXTURES TO THE J-BOX INDICATED THEN CONTINUE TO MDP.

PROVIDE AND INSTALL AN ENCLOSED RELAY AND A 4-SQUARE JUNCTION BOX

ALONG WITH A BLANK COVER ON THE WALL AT 60" AFF. PROVIDE IDENTIFICATION

ON THE BLANK COVER INDICATING WHICH LIGHTING FIXTURES ARE CONTROLLED.

PROVIDE ENCLOSED RELAY BY FUNCTIONAL DEVICES, INC. MODEL #RIB2421SB.

MOUNT RELAY AND THE J-BOX ABOVE AND TO THE LEFT OF MSB.

9. CONNECT TYPE X - EXIT SIGNS TO MDP CIRCUIT 29.

10.COORDINATION MAY BE REQUIRED BETWEEN PIPING AND LIGHT FIXTURE

LOCATIONS IN THE MECHANICAL ROOM. FINAL LOCATION OF FIXTURES TO BE

DETERMINED IN THE FIELD WITH DMVA REPRESENTATIVE AND APPROVED BY

ENGINEER.

1,2

1,2,3

1,2

1,2

LED EMERGENCY EXIT SIGN WITH BATTERY BACKUP

MOUNT HIGH ON WALL INTERIOR

SIDE (THERMOSTAT)

TEMPERATURE SENSOR

MOUNT HIGH ON WALL

EXTERIOR SIDE, 6" BELOW

EAVE (RED LIGHT)

1,2G&T FREEZE ALARM REFER TO COMMENTS AND DETAIL SEE THE "FREEZE ALARM & OPERATION DETAIL" , THIS SHEET

G T

GENERAL ELECTRICAL CONSTRUCTION NOTES (APPLIES TO ALL

ELECTRICAL DRAWINGS & DETAILS):

1. SEAL ALL FIRE RATED WALL & CEILING PENETRATIONS WITH FIRE RATED CAULK.

2. CONNECT ALL EMERGENCY LIGHTING AND EXIT SIGNS TO LOCAL LIGHTING CIRCUITS AHEAD OF THE ROOM LIGHTING

CONTROL.

3. COORDINATE LOCATIONS OF LIGHT FIXTURES WITH ALL PIPING, DUCTWORK, AND EQUIPMENT. MOUNT LIGHT FIXTURES TO

ALLOW THE GREATEST POSSIBLE HEADROOM.

4. UNLESS OTHERWISE NOTED OR DETAILED, INSTALL ALL CONDUCTORS IN CONDUIT. THIS INCLUDES FIRE ALARM, SOUND

AND PAGING, AND DATA CABLES.

5. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST ACCEPTED EDITION OF THE NATIONAL ELECTRICAL

CODE AND ALL STATE AND LOCAL CODES.

6. COORDINATE THE INSTALLATION OF ALL ELECTRICAL EQUIPMENT AND CONNECTIONS WITH ARCHITECTURAL AND

STRUCTURAL DRAWINGS.

7. "BACK TO BACK" OR THROUGH THE WALL BOXES SHALL NOT BE USED.

8. RECEPTACLES INDICATED AS GROUND FAULT CIRCUIT INTERRUPTER TYPE MAY BE EITHER GFI RECEPTACLES OR

SPECIFICATION GRADE DUPLEX RECEPTACLES CONNECTED TO A CIRCUIT PROTECTED BY A GFI CIRCUIT BREAKER.

9. PROVIDE EQUIPMENT GROUNDING CONDUCTORS IN EVERY POWER AND LIGHTING CONDUIT, ONE GROUNDING CONDUCTOR

FOR EACH CIRCUIT INCLUDING LIGHTING FIXTURE WHIPS (IF INSTALLED). ALL 120V CIRCUITS SHALL CONSIST OF AN UNGROUNDED CONDUCTOR, AN INSULATED NEUTRAL AND A GROUNDING CONDUCTOR. THERE SHALL BE NO SHARING OF

NEUTRALS.

10. ALL LIGHTING AND POWER CONDUCTORS SHALL BE 12 AWG MINIMUM.

11. MINIMUM CONDUIT SIZE SHALL BE 3/4" INTERNAL DIAMETER.

12. ARMORED CABLE TYPE AC or "BX" AND METAL CLAD TYPE MC CABLE SHALL NOT BE USED ON THIS PROJECT.

13. CONTRACTOR SHALL TRANSITION FROM PVC CONDUIT TO GALVANIZED RIGID METALLIC CONDUIT (GRC) WHEN TURNING UP

FROM BELOW A CONCRETE SLAB OR FROM BELOW GRADE TO ABOVE GRADE, WEATHER INDOORS OR OUTDOORS, BY INSTALLING A GRC NINETY DEGREE ELBOW AND THEN CONTINUING ABOVE SLAB OR GRADE UTILIZING GALVANIZED RIGID METAL CONDUIT. THIS APPLIES TO ALL RACEWAYS FOR ALL SYSTEMS INCLUDING DATA, UTILITY POWER AND/OR

EMERGENCY POWER, LIGHTING, & COMMUNICATIONS SYSTEMS.

14. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE PRIOR TO BIDDING TO VERIFY ALL EXISTING

CONDITIONS AND DIMENSIONS.

15. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR FURNISHING HIS SUBCONTRACTORS AND SUPPLIERS ALL THE NECESSARY CONTRACT DOCUMENTS TO ENSURE THEY INCLUDE ALL ITEMS IN THEIR BID THAT ARE WITHIN THEIR

DISCIPLINE.

16. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL WORK REQUIRED AND PERFORMED TO CARRY OUT THE INTENT OF

THIS PROJECT; INCLUDING THAT WORK REQUIRED AND PERFORMED BY THE SUBCONTRACTORS.

17. THE GENERAL CONTRACTOR SHALL HAVE A RESPONSIBLE REPRESENTATIVE FROM THEIR COMPANY ON SITE AT ALL TIMES DURING HIS COMPANY'S WORK, OR THE WORK OF ONE OF THE SUBCONTRACTORS. THIS REPRESENTATIVE SHALL HAVE ON SITE, HIS OWN COPY OF THE CONTRACT SPECIFICATIONS, DRAWINGS AND DMVA APPROVED SHOP DRAWINGS.

18. DISCREPANCIES FOUND BETWEEN THE SPECIFICATIONS AND THE DRAWINGS SHALL BE SUBMITTED TO DMVA IN THE FORM

OF AN RFI FOR CLARIFICATION PRIOR TO ANY WORK INVOLVING THIS DISCREPANCY.

WILLIAMS INDOOR

PTS-24-L49-835-RA-DIM-UNV

WILLIAMS INDOOR

96-4-L62-840-HIAFR-(L55)-DIM-UNV

120V OPERATION

B

BE

1,2

1,2,3

120V OPERATION, 4000K COLOR TEMP.WILLIAMS INDOOR

PTS-24-L38-835-RA-DIM-UNV

120V OPERATION, 4000K COLOR TEMP.

SURFACE MOUNT TO CEILING

SURFACE MOUNT TO CEILINGWILLIAMS INDOOR

PTS-24-L38-835-RA-DIM-UNVLED 2'x4' SURFACE MOUNT WITH BATTERY BACKUP

LED 2'x4' SURFACE MOUNT

LED EXTERIOR WALL-MOUNT FIXTURE WITH BATTERY

BACKUP

1,2

1,2,3

120V OPERATION, 3000K COLOR TEMP.

120V OPERATION, 3000K COLOR TEMP.

SURFACE MOUNT TO CEILING

SURFACE MOUNT TO CEILING

WILLIAMS INDOOR

EXIT-R-EM-WHT SURFACE MOUNT TO WALL

BEGHELLIE

MUR-EM-DB-CL-PIR

J 1,2

1,2,3

120V OPERATION, 4000K COLOR TEMP.

120V OPERATION, 4000K COLOR TEMP.

SURFACE MOUNT TO CEILING

SURFACE MOUNT TO CEILINGJE

CE LED INDUSTRIAL STRIP FIXTURE W/ BATTERY BACKUP

WILLIAMS INDOOR

75R-4-L85-840-DIM-UNV 120V OPERATIONCHAIN-HANG 8'-0" AFF 1,2

LED CLOSET LIGHT W/ BUILT IN PIR MOTION SENSOR

LED ROUND LENS STRIP W/ BATTERY BACKUP

WILLIAMS INDOOR

76R-4-L85-840-DIM-UNV

WILLIAMS INDOOR

76R-4-L85-840-DIM-UNV

WILLIAMS INDOOR

PTS-14-L45-835-RA-DIM-UNV

WILLIAMS INDOOR

PTS-14-L45-835-RA-DIM-UNVLED 1'x4' SURFACE MOUNT WITH BATTERY BACKUP

LED 1'x4' SURFACE MOUNT

LIGHTING PLAN, SCHEDULES, AND DETAILS

NOTESTECHNOLOGYMANUFACTURER & CAT. NO.MARK MOUNTING LOCATION

CEILING MOUNT

OCCUPANCY SENSOR SCHEDULE

1, 2

DESCRIPTION

NEW OCCUPANCY

SENSOR DUAL TECHNOLOGYLEGRAND WATTSTOPPER

#LMDC-100-U

OC1

CEILING MOUNT 1, 2, & 3NEW OCCUPANCY

SENSOR DUAL TECHNOLOGYLEGRAND WATTSTOPPER

#DT-300-U

OC2

WATTS

3120V OPERATION, RED LETTERS 1,2,3

AutoCAD SHX Text 105N

AutoCAD SHX Text

AutoCAD SHX Text 103S

AutoCAD SHX Text 101S

AutoCAD SHX Text 100N

AutoCAD SHX Text 101N

AutoCAD SHX Text 103N

AutoCAD SHX Text 100N

AutoCAD SHX Text

105NA

AutoCAD SHX Text 102N

AutoCAD SHX Text 100S

AutoCAD SHX Text 104N

AutoCAD SHX Text 102S

AutoCAD SHX Text 104S

AutoCAD SHX Text 105S

AutoCAD SHX Text

105SA

AutoCAD SHX Text 106N

AutoCAD SHX Text 106S

AutoCAD SHX Text 100S

AutoCAD SHX Text R

AutoCAD SHX Text B

AutoCAD SHX Text W

AutoCAD SHX Text

TUEBOR

AutoCAD SHX Text U

AutoCAD SHX Text S

AutoCAD SHX Text Q

AutoCAD SHX Text U

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text M

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text

KAB

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text M

AutoCAD SHX Text L

AutoCAD SHX Text A

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text C

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text U

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

CONSTRUCTION

AutoCAD SHX Text

FINAL RECORD

AutoCAD SHX Text

DATE

AutoCAD SHX Text

ISSUED FOR

AutoCAD SHX Text

INDEX CODE

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text

IDENTIFICATION NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

AutoCAD SHX Text

FACILITIES AND BUSINESS SERVICES ADMINISTRATION

AutoCAD SHX Text

ADAM LACH RA, DIRECTOR

AutoCAD SHX Text

JDJ

AutoCAD SHX Text

AJP

AutoCAD SHX Text

KAB

AutoCAD SHX Text

KAB

AutoCAD SHX Text N

AutoCAD SHX Text W

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text W

AutoCAD SHX Text E

BRIGADE ROAD

BASKETBALL

COURT

Q (5

Q (5

Q (4

Q (4

Q (5

Q (5

Q (5

M A

M A

M A

M A

7t h

S

TR

EE

T

S O

U

TH

526M528M53

M A53

M

A

3 3

BRIGADE ROAD

BASKETBALL

COURT

Q (5

Q (5

Q (4

Q (4

Q (5

Q (5

Q (5

M A

M A

M A

M A

7t h

S

TR

EE

T

S O

U

TH

526A

526M528M53

M A53

M

A

TWO EXISTING 4" UNDERGROUND

CONDUITS WITH EXISTING CABLESCC2

PB2

UTILITIES

989-344-6184

72 HOURS

(3 WORKING DAYS)

CALL Mr. Halcomb

BEFORE YOU DIGC.G.

MICHAEL HALCOMB

CAMP GRAYLING ENGINEERING

KAB'17

KNOW WHAT'S BELOW.

CALL BEFORE YOU DIG.

NOTE:

· SEE SHEET C-1 FOR SITE UTILITIES.

PROPOSED ELECTRICAL SITE POWER PLANE KEY NOTES X :

1. PROVIDE AND INSTALL NEW 3-POLE CIRCUIT BREAKER(S) IN THE EXISTING EXTERIOR SWICHBOARD P-538 FOR BUILDING 536Q (AND

534Q IF INCLUDED IN THIS PROJECT). UPGRADE MAIN BREAKER FROM 80% RATED TO 100% RATED ((MAIN CIRCUIT BREAKER BREAKER UPGRADE TO BE PERFORMED EVEN IF DEDUCT ALTERNATE NO. 1 IS ACCEPTED, DO NOT INCLUDE IN DEDUCT ALT. NO. 1 SCOPE.)

REFER TO SHEET E6 FOR CIRCUIT BREAKER SIZES.

2. PROVIDE AND INSTALL A NEW UNDERGROUND BUILDING ELECTRICAL FEEDER FROM SWICHBOARD P-538 TO BUILDING 536Q (AND 534Q

IF INCLUDED IN THIS PROJECT). REFER TO SHEET E6 FOR CONDUCTOR SIZE AND COUNT.

3. EXISTING UNDERGROUND FEEDERS TO EACH BUILDING SHOWN. CONTRACTOR SHALL DISCONNECT BOTH ENDS OF THE FEEDER TO BUILDING 536Q (AND 534Q IF INCLUDED IN THIS PROJECT), REMOVE FROM THE SWITCHBOARD P-538 AND EACH BUILDING, CUT 5 FEET

AWAY FROM THE SWITCHBOARD OR BUILDING AND ABANDON IN PLACE.

4. EXISTING UNDERGROUND FEEDER FROM SWITCHBOARD P-538 TO THIS BUILDING TO REMAIN.

HAND HOLE SCHEDULE

MARK

HH-A

DESCRIPTION BOX MANUFACTURER & CAT. NO. REMARKS NOTES

HAND HOLE SCHEDULE NOTES:

1. CONTRACTOR MAY SUBSTITUTE HAND HOLES BY OTHER MANUFACTURERS IF EQUAL IN ALL RESPECTS. SUBMIT SHOP DRAWING FOR ALL SUBSTITUTIONS.

PRECAST POLYMER CONCRETE ENCLOSURE QUAZITE #PG1730BA18 COVER SHALL HAVE "COMMUNICATIONS" LOGO 1

COVER MANUFACTURER & CAT. NO.

QUAZITE #PG1730HH00-12

ANSI TIER: 22 ANSI TIER: 22NOMINAL INTERIOR DIMENSIONS: 17"x30" BOX SHALL HAVE STRAIGHT SIDES HH-B PRECAST POLYMER CONCRETE ENCLOSURE QUAZITE #PC0608BA06 COVER SHALL HAVE "ELECTRIC" LOGO 1QUAZITE #PC0608HA00-17

ANSI TIER: 15 ANSI TIER: 15NOMINAL INTERIOR DIMENSIONS: 6"x8" BOX SHALL HAVE STRAIGHT SIDES

PROPOSED ELECTRICAL SITE POWER PLAN

SCALE 1" = 50'-0"

PROPOSED COMMUNICATIONS SITE PLAN

SCALE 1" = 50'-0"

PROPOSED COMMUNICATION SITE PLAN KEY NOTES X :

1. LOCATIONS OF THE EXISTING COMMUNICATIONS HAND HOLES AND JUNCTION BOXES ARE APPROXIMATE. CONTRACTOR SHALL VISIT THE

SITE AND FIELD VERIFY.

2. INSTALL (2) 2" CONDUITS UNDERGROUND FROM THE NEW HANDHOLE HH-A, TO MECHANICAL ROOM 107, TO A POINT UNDER THE NEW

COMMUNICATIONS RACK BACKBOARD AND NINETY-UP TO A POINT 3" ABOVE THE FINISH FLOOR LEVEL. INSTALL A METALLIC BUSHING

WITH INSULATED THROAT.

3. INSTALL NEW HH-A HANDHOLE FLUSH WITH GROUND. PULL EXISTING COPPER AND NEW FIBER CABLE THROUGH THIS HANDHOLE; NEW HANDHOLE TO BE PRECAST POLYMER CONCRETE ENCLOSURE WITH NOMINAL INTERIOR DIMENSIONS OF 17"X30". REFER TO THE "HAND

HOLE SCHEDULE", THIS SHEET. COIL-UP ANY EXTRA FIBER CABLE WITHIN THIS HANDHOLE.

4. PROVIDE AND INSTALL A NEW 12-STRAND FIBER CABLE; TYPE AS REQUIRED IN SPECIFICATION SECTION 270500. TERMINATE ALL 12 FIBERS IN BUILDING 536Q (AND 534Q IF PART OF THE CONTRACT). DIRECT BURY FIBER LINE FROM THE PULL BOX IDENTIFIED IN THE DRAWING ABOVE. ROUTE FIBER THROUGH THE NEW HH-A HAND HOLE ADJACENT TO EACH BUILDING AND TERMINATE THE FIBER IN THE FIBER EQUIPMENT INSIDE THE BUILDING. COORDINATE FIBER RUN LOCATIONS WITH CAMP GRAYLING TELECOMM/ENGINEERING

DEPARTMENT.

5. REINSTALL THE EXISTING UNDERGROUND TELEPHONE CABLE AND COMMSCOPE BEP ENCLOSURE THROUGH THE NEW HH-A HANDHOLE

AND INTO THE BUILDING WITHIN ONE OF THE NEW 2" CONDUITS.

6. APPROXIMATE ROUTE OF EXISTING UNDERGROUND FIBER OPTIC CABLE. CONTRACTOR SHALL COORDINATE THE INSTALLATION OF THE NEW CABLE RUNS WITH THE EXISTING. CONTACT BASE TELECOMM/ENGINEERING DEPARTMENTS FOR LOCATING.

7. RESTORE ALL DISTURBED AREAS PER SPECIFICATIONS.

8. COORDINATE WITH THE OTHER SITE PLANS; C1, C2 & C3.

9. JACK AND BORE NEW CABLES UNDER ALL CONCRETE WALKWAYS AND STAIRWAYS.

HH#

COMMUNICATIONS SYMBOL LEGEND

UNDERGROUND DUCT RUN

NEW OR EXISTING HAND HOLE

DESCRIPTIONSYMBOL

PB# EXISTING PULL BOX

CC# EXISTING CROSS CONNECT PEDESTAL

UNDERGROUND DIRECT BURY FIBER RUN

ELECTRICAL SYMBOL LEGEND

NEW POWER HAND HOLE, REFER TO NOTE

DESCRIPTIONSYMBOL

NEW UNDERGROUND POWER CIRCUIT

EXISTING EXTERIOR DISTRIBUTION PANEL

TRANSFORMER

EXISTING MEDIMUM VOLTAGE PADMOUNT

D

EP

AR

TM

EN

T

O F

M

IL

IT

AR

Y

AN

D V

ET

ER

AN

S

AF

FA

IR

S

ST

AT

E O

F M

IC

H

IG

AN

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

B1

E-

JU

L

R

EN

O

VA

TE

B

U

IL

D

IN

G

Q

/5

Q C

AM

P

G R

AY

LI

N G

J O

IN

T

M

AN

EU

VE

R T

R

AI

N

IN

G C

EN

AY

LI

N G

, M

IC

H

IG

AN

ALL DETAILS WITHIN ARE FOR BOTH BUILDING 536Q AND

BUILDING 534Q UNLESS OTHERWISE NOTED.

UNLESS OTHERWISE NOTED, SCHEDULES SHOWN ARE FOR 1

EACH BUILDING; CONTRACTOR SHALL BE RESPONSIBLE FOR

THE QUANTITIES NEEDED AND REQUIRED IF BOTH BUILDINGS

536Q AND 534Q ARE REMODELED.

ALL DETAILS WITHIN ARE FOR BOTH BUILDING 536Q AND BUILDING 534Q

UNLESS OTHERWISE NOTED. BASE BID INCORPORATES BOTH BUILDINGS

536Q & 534Q. CONTRACTOR SHALL BE RESPONSIBLE FOR THE

QUANTITIES NEEDED AND REQUIRED IF BOTH BUILDINGS 536Q AND 534Q

ARE REMODELED. IF PRICING IS TOO HIGH, BUILDING 534Q WILL BE

DROPPED FROM THE CONTRACT (DEDUCTIVE ALTERNATE) SO BIDDING

CONTRACTORs NEED TO DO THEIR TAKE-OFFs WITH THIS IN MIND.

NO SCALE

FINISHED GRADE

INSTALL HANDHOLES WITH HEAVY DUTY RATING AS

SPECIFIED. PROVIDE WITH STAINLESS STEEL BOLTS

AND A "COMMUNICATIONS" OR "ELECTRIC" LOGO IN A

HEAVY DUTY COVER

PROVIDE HAND HOLES

WITH OPEN BOTTOMSOR CRUSHED STONE

6" TO 8" OF GRAVEL

30°

HAND HOLE INSTALLATION DETAIL

GRAVEL BASE TO

EXTEND 4" PAST

THE SIDE OF THE

HAND HOLE, ON

ALL SIDES.

HAND HOLE INSTALLATION NOTES:

1. REFER TO SHEET E4 FOR HAND HOLE LOCATIONS.

2. REFER TO THE HAND HOLE SCHEDULE ON SHEET E4 FOR SIZE AND MANUFACTURER

INFORMATION.

ELECTRICAL SITE PLANS, DETAIL, AND SCHEDULES

HH-BHH-B

HH-A HH-A

AutoCAD SHX Text 115'

AutoCAD SHX Text 42'

AutoCAD SHX Text 20'

AutoCAD SHX Text 20'

AutoCAD SHX Text 57'

AutoCAD SHX Text 79'

AutoCAD SHX Text 32'

AutoCAD SHX Text 20'

AutoCAD SHX Text 67'

AutoCAD SHX Text 49'

AutoCAD SHX Text

SWALE

AutoCAD SHX Text

T-538 EXISTING PADMOUNT TRANSFORMER 500KVA 3 PHASE 208/120

AutoCAD SHX Text 87'

AutoCAD SHX Text

T-540 SN05A132074 500KVA 3 PHASE 208/120

AutoCAD SHX Text 52'

AutoCAD SHX Text

EXISTING SWITCHBOARD P-538

AutoCAD SHX Text N

AutoCAD SHX Text W

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text W

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text W

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text W

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text

TUEBOR

AutoCAD SHX Text U

AutoCAD SHX Text S

AutoCAD SHX Text Q

AutoCAD SHX Text U

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text R

AutoCAD SHX Text C

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text M

AutoCAD SHX Text I

AutoCAD SHX Text S

AutoCAD SHX Text

KAB

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text U

AutoCAD SHX Text P

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text B

AutoCAD SHX Text U

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text I

AutoCAD SHX Text M

AutoCAD SHX Text L

AutoCAD SHX Text A

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text C

AutoCAD SHX Text M

AutoCAD SHX Text M

AutoCAD SHX Text U

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

CONSTRUCTION

AutoCAD SHX Text

FINAL RECORD

AutoCAD SHX Text

DATE

AutoCAD SHX Text

ISSUED FOR

AutoCAD SHX Text

INDEX CODE

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text

IDENTIFICATION NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESIGNED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET

AutoCAD SHX Text

FACILITIES AND BUSINESS SERVICES ADMINISTRATION

AutoCAD SHX Text

ADAM LACH RA, DIRECTOR

AutoCAD SHX Text

JDJ

AutoCAD SHX Text

AJP

AutoCAD SHX Text

KAB

AutoCAD SHX Text

KAB

AutoCAD SHX Text

BURIAL DEPTHS BELOW GRADE*

AutoCAD SHX Text *FOR ALL CAMP ELECTRICAL & COMMUNICATIONS SYSTEMS, THESE MEASUREMENTS ARE BELOW FINISHED GRADE. *TO BE USED FOR NEW INSTALLATIONS ONLY, VERIFY ALL EXISTING DEPTHS AND LOCATIONS

AutoCAD SHX Text

ELECTRICAL

AutoCAD SHX Text 40"

AutoCAD SHX Text 36"

AutoCAD SHX Text

TELEPHONE

AutoCAD SHX Text 30"

AutoCAD SHX Text

CATV

AutoCAD SHX Text 30"

AutoCAD SHX Text

FIBER OPTIC

AutoCAD SHX Text 30"

AutoCAD SHX Text

PRIMARY

AutoCAD SHX Text

ELECTRICAL

SECONDARY

BUILDING

CENTERLINE

180'-0"

S

S S

S S

F F

F

F

F

FF

F

F

F

S S S

S S

SF

NOTE 1

NOTE 1

F

NOTE 1

F

NOTE 1

F

NOTE 12, 14

S

D

S AHU-2

D

SAHU-1

AHU-2

FACP

MDP

H A

F S

F

F

SSS

SSS

SSS

SSS

S S

H H

F

MDP-21

S

S

FLOW AND TAMPER

SWITCHES, SEE

NOTE 13

FIRE SUPPRESSION

SYSTEM HORN &

STROBE, NOTE 13

'-4

C

C

C C

C

D

EP

AR

TM

EN

T

O F

M

IL

IT

AR

Y

AN

D V

ET

ER

AN

S

AF

FA

IR

S

ST

AT

E O

F M

IC

H

IG

AN

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

B1

E-

AP

R

R

EN

O

VA

TE

B

U

IL

D

IN

G

Q

/5

Q C

AM

P

G R

AY

LI

N G

J O

IN

T

M

AN

EU

VE

R T

R

AI

N

IN

G C

EN

AY

LI

N G

, M

IC

H

IG

AN

PROPOSED FIRE ALARM PLAN NOTES:

1. MOUNT THE HORN/STROBE 12" BELOW THE CEILING AND THE MANUAL PULL STATION DIRECTLY BELOW THE HORN/STROBE UNIT AT 48" AFF TO THE PULL HANDLE.

2. PROVIDE AND INSTALL THREE (3) RATE OF RISE HEAT DETECTORS IN THE ATTIC SPACE, ONE IN EACH OF THE THREE FIRE RATED AREAS. PROVIDE THESE THREE HEAT

DETECTORS WITH A REMOTE ALARM INDICATING LED OUTPUT OPTION. REMOTE LEDS SHALL BE LOCATED IN AN ENCLOSURE NEXT TO THE FIRE ALARM CONTROL PANEL

IN ROOM 107.

3. PROVIDE AND INSTALL A REMOTE HEAT DETECTOR MONITORING UNIT WITH LEDS TO INDICATE WHEN THE ATTIC HEAT DETECTORS ARE IN ALARM.

4. COORDINATE CEILING MOUNTED FIRE ALARM DEVICES WITH LIGHTING FIXTURES AND HVAC DIFFUSER LOCATIONS.

5. ALL FIRE ALARM WIRING SHALL BE IN CONDUIT, 3/4" MINIMUM.

6. WIRING SHALL NOT BE LOOPED THROUGH DEVICES; WIRE MUST BE CUT FOR IN AND OUT CONNECTIONS .

7. POINT AND COMMON ANNUNCIATION SHALL NOT BE USED. NON-ADDRESSABLE CIRCUITS T-TAPPING IS NOT ALLOWED.

8. ALL DEVICES IN THE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED TO MANUFACTURER'S SPECIFICATIONS.

9. WALL-MOUNTED STROBES SHALL HAVE THEIR BOTTOMS NOT LESS THAN 80" AFF AND NO GREATER THAN 96" AFF.

10. ALL JUNCTION BOXES IN THE ATTIC SHALL BE SECURED TO A TRUSS AND MOUNTED ABOVE THE INSULATION LINE.

11. ALL EXPOSED FIRE ALARM CONDUIT SHALL BE PAINTED TO MATCH THE WALLS/CEILINGS FINISH COLOR. EXPOSED CONDUIT IS ALLOWED ON THE CEILINGS. UTILIZE

COMPRESSION FITTINGS (COUPLINGS & CONNECTORS) FOR THESE RACEWAYS.

12.STACK FIRE ALARM CONTROL PANEL AND BATTERY CABINETS IF MULTIPLE CABINETS ARE REQUIRED. DO NOT PLACE SIDE-BY-SIDE.

13.FIRE SUPPRESSION EQUIPMENT. CONTRACTOR SHALL PROVIDE AND INSTALL THE CONNECTION OF FIRE SUPPRESSION EQUIPMENT TO THE FIRE ALARM CONTROL PANEL

CONSISTING OF THREE BUTTERFLY VALVE TAMPER SWITCHES, ONE AIR COMPRESSOR, TWO FLOW SWITCHES, ONE EXTERIOR MOUNTED HORN & STROBE UNIT, AND ONE

ELECTRIC BELL.

14.ROUTE ONE CAT-6 CABLE IN 3/4" CONDUIT FROM THE DATA RACK TO THE NEW FIRE ALARM PANEL. TERMINATE BOTH ENDS SUCH THAT THE FIRE ALARM PANEL CAN BE

CONNECTED TO THE CAMP'S DATA NETWORK.

FIRE ALARM NOTES

1. PROVIDE AND INSTALL ALL FIRE ALARM DEVICES AS REQUIRED PER THE CURRENT EDITION IN

EFFECT OF NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE.

2. FINAL LAYOUT TO BE DESIGNED BY A LICENSED AND CERTIFIED FIRE ALARM SYSTEM PROFESSIONAL.

FIRE ALARM SHOP DRAWINGS MUST BE SUBMITTED BY THE CONTRACTOR TO…

This is the start of the file's text. The full file is on GovTribe.