About this file
This document is a Subcontractor Summary Worksheet template issued by the City of St. Petersburg, Florida, designed for bidders on a shelter project to disclose all intended subcontractors as part of their bid submission. The worksheet requires prime contractors to identify themselves, provide the name and date of the employee completing the form, and list comprehensive information for each subcontractor including legal name, primary business address, project supervision contact details, tier classification, trade classifications, and subcontract amounts. The document specifies that up to 80 percent of the shelter contract work may be subcontracted, with restrictions limiting subcontractors to first and second tier levels unless otherwise noted in contract documents. Subcontractors cannot be changed or substituted after award and the pre-construction meeting except under seven specified circumstances, including failure to execute a contract, lack of proper licensing, insolvency, ineligibility, performance failures, unsatisfactory work quality, or substantial project delays.
The worksheet establishes that Small Business Enterprise (SBE) or Minority/Women Business Enterprise (MWBE) subcontractors used to meet SBE percentage requirements must be replaced with other SBE subcontractors if substitution becomes necessary, unless the prime contractor demonstrates SBE requirements are being met through alternative means. Requests for subcontractor changes must be submitted in writing to the City's Procurement & Supply Management office, specifically to the Contracts Compliance Manager. The document notes that restrictions on subcontracting percentages and multiple-tier subcontractor use do not apply to Federal-aid Local Agency Program (FDOT LAP) or federally funded projects. The worksheet includes a legend identifying seven reason codes for potential subcontractor deletions and requires city approval and date notation for any additions or deletions to the subcontractor list.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Chemical,_Calcium_Oxide.pdf | ||
| Agreement_.pdf | ||
| FILLABLE_LETTER_OF_INTENT_BEP-FORM_A.pdf | ||
| Bid_Bond_.docx | DOCX document | |
| FILLABLE_BEP_NON-USE_BEP_FORM_B.pdf | ||
| Performance_&_Payment_Bond_.DOCX | DOCX document | |
| Subcontractor_Summary_Spreadsheet.xlsx | XLSX spreadsheet | |
| Public_Construction_Bond.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Instructions
| City of St. Petersburg |
| Subcontractor Summary Instructions |
WORKSHEET MUST BE COMPLETED AND SUBMITTED WITH YOUR BID
1. The Subcontractor Worksheet reflects the percentage of work which may be subcontracted for this project. Refer to Contract Standards, Instructions to Bidders, Article I-13, Subcontractors for applicable rules.
2. Enter the name of your company in the Prime Contractor field.
3. Enter the name and date of Prime Contractor employee completing this form.
4. Provide all information requested on each intended subcontractor. If subcontractors will NOT be used for this project, provide a written statement on the Subcontractor List indicating the same.
5. Subcontractors may not be changed or substituted once a Prime Contractor is awarded the project (and the pre-construction meeting held), except for the following reasons:
A. Subcontractor fails or refuses to execute a written contract for the scope of work as specified at the price specified;
B. Subcontractor is not appropriately licensed to perform the scope of work;
C. Subcontractor becomes bankrupt or insolvent;
D. Subcontractor is ineligible to perform the work on the project;
E. Subcontractor fails or refuses to perform its subcontract;
F. Engineer determines the work performed by the subcontractor is substantially unsatisfactory and not in substantial accordance with the plans and specifications;
G. Subcontractor is substantially delaying or disrupting the progress of the work.
Requests for changes to the Subcontractor List shall be made in writing to the Procurement & Supply Management, Attention: Contracts Compliance Manager at Stephanie.Swinson@stpete.org.
6. SBE subcontractors used to meet the SBE percentage requirement, if replaced, shall be replaced with a SBE subcontractor, unless the Prime Contractor demonstrates that SBE requirements are being met in another way.
7. Restrictions on subcontracting percentage and use of multiple-tier subcontractors do not apply to FDOT LAP or federally funded projects.
Subcontractor Worksheet
| City of St. Petersburg |
| Subcontractor Summary |
| Project Name: |
| Project Number: |
| Percentage of Contract Which May be Subcontracted: 80% for Shelter Bid |
| Name of Prime Contractor: | Cells below will be "hidden" on the worksheet since they are only for Procurement's use. |
| Name/Date of Individual Completing this Form: |
| City of St. Petersburg SBE or MWBE Contractor Yes or No | Subcontractor's Name (Provide complete Legal Name) | Subcontractor's Primary Business Address | Name/Phone Number and Email Address of Subcontractor's Employee Responsible for Project Supervision | First or Second Tier Subcontractor* | Trade Classification(s) Being Subcontracted (List One Trade per Line) | Subcontract Amount ($) | Added (A) Deleted (D) | Reason Code | City Approver/Date | Add (A) and Delete (D) Legend |
| Example: Yes | XYZ Contractors, Inc. | 123 N. Burlington Ave., St. Petersburg, FL 33701 | Joe Jones - 727-555-555 Email - XYXCon@yahoo.com | First | Electrical | 13,234.00 | D | B | Employee XYZ/03-01-19 | A. Subcontractor fails or refuses to execute a written contract for the scope of work as specified at the price specified; |
| B. Subcontractor is not appropriately licensed to perform the scope of work; | ||||||||||
| C. Subcontractor becomes bankrupt or insolvent; | ||||||||||
| D. Subcontractor is ineligible to perform the work on the project; | ||||||||||
| E. Subcontractor fails or refuses to perform its subcontract; | ||||||||||
| F. Engineer determines the work performed by the Subcontractor is substantially unsatisfactory and not in substantial accordance with the Plans and Specifications; |
G. Subcontractor is substantially delaying or disrupting the progress of the work.
Total: 0.00
| *Only first and second tier subcontractors are permitted unless noted otherwise in the Contract Documents. | Contract Amount | |
| 0.00 | Amount Allowed to be Subcontracted |
&8Rev. January 2020 &10Page 1 of &P
File details come from the government source that posted it. Updated .