This document contains construction drawings and details for proposed improvements at Fort Lawton National Cemetery. The drawings show fencing details including post types, rails, fabric, footings and other specifications. Related to this is a federal contract opportunity posted by the Department of Veterans Affairs National Cemetery Administration for cemetery improvements at Fort Lawton National Cemetery. The project number is 951-MM-FY23-002 and includes fencing, as detailed in the construction drawings. The solicitation number is 36C78623B0015. The response is due for the improvements, with award anticipated.
View the file
Other files
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1FENCING DETAILS
1"=1'-0"
17' HEIGHT FENCE RAIL
1"=1'-0" 2CHAIN LINK FENCE RAIL
1"=1'-0"
AutoCAD SHX Text
2 3/8" O.D TERMINAL POST FENCE END AND DIRECTION CHANGE OF 30° OR MORE
AutoCAD SHX Text
POST TOP (AS SPECIFIED)
AutoCAD SHX Text
1 7/8" O.D. TOP RAIL: JOINTS TO HAVE 6" SLEEVES FOR EXPANSION/CONTRACTION
AutoCAD SHX Text CHAIN LINK FABRIC TO BE 6 GAUGE, WITH CLASS 1 ASTM F668 FABRIC POLYMERCOATING, OR VINYL COATED, COLOR BLACK. MESH SIZE TO BE 2", TYP.
AutoCAD SHX Text 1 5/8" O.D. BRACE RAIL (BOTH SIDES OF TERMINAL POSTS, MID-HT.) RED'Q. FOR HEIGHTS 6' AND OVER.
AutoCAD SHX Text
TENSION BAR
AutoCAD SHX Text
TENSION BAND WITH CARRIAGE BOLTS AND NUTS
AutoCAD SHX Text
3,000 PSI CONCRETE FOOTING 12" DIA. TYP.
AutoCAD SHX Text
COMPACTED SUBGRADE
AutoCAD SHX Text
RAIL TIE
AutoCAD SHX Text
CHAIN LINK, TOP SELVAGE KNUCKLED
AutoCAD SHX Text
LINE POST TOP
AutoCAD SHX Text
1-7/8"O.D. LINE POST (10' O.C. MAX)
AutoCAD SHX Text
WIRE TIES FOR ATTACHMENT OF FABRIC TO LINE POSTS (12" O.C. MAX)
AutoCAD SHX Text
ADJUSTABLE 3/8" DIA. TRUSS ROD (REQ.'D IN CONJUNCTION W/ BRACE RAILS)
AutoCAD SHX Text
1 7/8" O.D. BOTTOM RAIL: JOINTS TO HAVE 6" SLEEVES FOR EXPANSION/CONTRACTION
AutoCAD SHX Text
PROVIDE 1/2" RADIUS & SMOOTH TROWEL FINISH ACROSS TOP OF FOOTING (TYP.)
AutoCAD SHX Text
BOTTOM SELVAGE KNUCKLED
AutoCAD SHX Text
BRACE BAND
AutoCAD SHX Text
FABRIC HT. VARIES. SEE PLAN.
AutoCAD SHX Text
4' DEPTH FOR FENCES UP TO 6' TALL 5' DEPTH FOR FENCES UP TO 10' TALL
AutoCAD SHX Text NOTE: ALL FENCE FABRIC, POSTS, RAILS, GATES, AND ACCESSORIES TO BE GALVANIZED AND RECEIVE THERMALLY FUSED AND BONDED BLACK VINYL COATING.
AutoCAD SHX Text
3,000 PSI CONCRETE FOOTING MIN. 4X DIA. OF POST WIDTH, TYP.
AutoCAD SHX Text
3"X3" POST, TYP.
AutoCAD SHX Text
1"X1" RAIL, TYP.
AutoCAD SHX Text
1"X1" PICKET, TYP.
AutoCAD SHX Text
PROVIDE 1/2" RADIUS & SMOOTH TROWEL FINISH ACROSS TOP OF FOOTING (TYP.)
AutoCAD SHX Text
MIN. DIA. 3X POST WIDTH
AutoCAD SHX Text Project Title
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Dwg. of
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
CONSULTANTS:
AutoCAD SHX Text
ARCHITECT/ENGINEERS:
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text Project Number
AutoCAD SHX Text
ATIONAL
AutoCAD SHX Text
EMETERY
AutoCAD SHX Text
DMINISTRATION
AutoCAD SHX Text V
AutoCAD SHX Text T
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text I
AutoCAD SHX Text D
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text Approved
AutoCAD SHX Text Date
AutoCAD SHX Text Approved-Project Manager
AutoCAD SHX Text Checked
AutoCAD SHX Text Drawn
AutoCAD SHX Text Location
AutoCAD SHX Text Ft. Lawton National Cemetery Texas Way Seattle, WA 98199
AutoCAD SHX Text Ft. Lawton Cemetery Improvements
AutoCAD SHX Text Craig Robbins
AutoCAD SHX Text Keith Royster
AutoCAD SHX Text
951-MM-FY23-002
| Sheets and Views |
| Ft. Lawton Cemetery Improvements-Details (5) |
File details come from the government source that posted it. Updated .