This document is an Existing Site Sewer Plan, a technical drawing prepared by Royal Engineers & Consultants, LLC for underground infrastructure work at 1500 Woodrow Wilson Avenue in Jackson, Mississippi 39216. The plan is designated as drawing C102 and depicts Phase II of an underground infrastructure project.
The plan illustrates the site's sanitary sewer system layout using standardized symbols and a site legend. Key infrastructure elements shown include sewer lines with numbered sanitary sewer manholes (labeled 1-20), grease traps (marked with red dots), concrete flumes, control points with 60D nails for survey reference, storm drain lines and manholes, fire lines with hydrants, water lines with valves, electrical lines with manholes, fencing, power poles, and site lighting. The drawing includes a north directional indicator and is scaled at 1 inch = 320 feet for the overall site plan and 1 inch = 80 feet for detailed sections. The document was prepared by Royal Engineers & Consultants, LLC, located at 601 Elysian Fields Avenue, New Orleans, Louisiana 70117, with contact information provided. A revisions section is included on the drawing for tracking any design modifications.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25626Q0216 0004.docx | DOCX document | |
| Updated Sewer Site Plan.pdf | ||
| 36C25626Q0216 0002.docx | DOCX document | |
| 36C25626Q0216 0001_1.docx | DOCX document | |
| 36C25626Q0216v3.pdf | ||
| 36C25626Q0216_1.docx | DOCX document | |
| WD 2015-5153 Rev 29.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONC.
FLUME
X
I X
I
CONC.
FLUME-�=,1
I.
I
X
I X
I X
CONC. j
FLUME.-�:;--,
I X
I X
I X
I
CONC. • '
FLUME-t=i r , I X
I
II '·"
1• I w
I I I •
I w i I w
I
I
NORTH
w I I fw
I Iw w I w i
...... , .. --, .. , ... __ _____ J ...
z
(102
EXISTING SITE SEWER PLAN
SCALE:
320' 10' 40' 80' 160'
0' 20'
CONTROL
POINT 3
60D NAIL
:l
Ii
CONTROL
Ii POINT 1
I\ 60D NAIL
it Ii
SITE LEGEND
-s-s-s-@
--F-F-F----$
-E-E-E----«)
REVtSIOH
SEWER LINE AND SEWER MANHOLE
STROM DRAIN LINE AND STORM DRAIN MANHOLE
FIRE LINE AND FIRE HYDRANT
WATER LINE AND WATER VALVE
ELECTRICAL LINE AND ELECTRICAL MANHOLE
FENCE
POWER POLE
SITE LIGHTING
BUILDING
ROY AL ENGINEERS
& CONSULTANTS, LLC
601 ELYSIAN FIELDS AVENUE
NEW ORLEANS, LOUISIANA 70117
Phone: 504.309.4129 Fax: 504.309.3983 v,ww.royalengineering.net
REVISIONS
REVISION DESCRIPTION OATIS
UNDERGROUND INFRASTRUCTURE
PHASE II
1500 WOODROW WILSON AVENUE
JACKSON, MISSISSIPPI 39216
EXISTING SITE SEWER PLAN
C102
(a)(b) (c)
(d)
Red Dots- Grease Traps
Red Numbers- Sanitary Sewer Manholes
(1)
(3)
(4)
(5,6)
(7)
(8)
(9)
(10)
(11)
(12)
(2)
(13,14,15)
(16)
(17) (18)
(19)
(20)