This is a technical specification document for telescopic gymnasium seating, outlining comprehensive requirements for the design, fabrication, and installation of wall-attached forward-folding seating systems. The specification details a gymnasium seating project requiring a bank length of 96 feet 6 inches with 10 tiers, 24-inch row spacing, and 9-5/8-inch row rise. The seating system must be electrically operated with integral power using a 1/2 horsepower motor running on 208V 3-phase power at 60 Hz, capable of opening and closing the entire bank via pendant control. The specification includes detailed performance requirements, including live loads of 120 pounds per linear foot on seats and decking, uniformly distributed loads of 100 pounds per square foot, parallel sway loads of 24 pounds per linear foot, and perpendicular sway loads of 10 pounds per linear foot. The project requires a Courtside Collection XC10 polymer seat system with gas-assisted injection-molded high-density polyethylene modules measuring 18 inches long by 10 inches deep, rated for 600-pound module loads.

The specification identifies Hussey Seating Company (North Berwick, Maine) as the basis of design manufacturer for the MAXAM Telescopic Gym Seat System, with Interkal Spectator Seating Worldwide listed as an acceptable alternative. The system includes a 10-year structural component warranty on understructure components and a 5-year warranty covering decking systems, seating collections, electrical systems, and finish materials from the date of acceptance. The specification mandates manufacturer qualification of minimum 40 years' experience in telescoping stand manufacturing with 25-year product support capability, and installer qualification through factory certification with demonstrated experience on ten comparable projects in service for at least five years. All materials must comply with applicable ASTM standards, AWS welding codes, and ICC 300 standards for bleachers, folding and telescopic seating. The specification requires comprehensive shop drawings, load test reports certified by a registered professional structural engineer, and factory-authorized technician training with four to eight-hour maximum on-site repair response during normal business hours.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION 126613 – TELESCOPIC SEATING

PART 1 GENERAL

1.1 SUMMARY

A. Section Includes: Telescopic Gym Seating includes electrically operated multiple-tiered seating rows comprising of seat, deck components, understructure that permits closing without requiring dismantling, into a nested configuration for storing or for moving purposes.

1. Wall-attached telescoping stands

B. Related Sections:

1. Division 26 Electrical sections for electrical wiring and connections for electrically operated telescoping stands.

1.2 REFERENCES

A. Aluminum Association (AA):

1. ADM 1- Aluminum Design Manual

B. American Institute of Steel Construction (AISC):

1. AISC 360- Steel Construction Manual.

C. American Iron & Steel Institute (AISI):

1. AISI S100 – Design of Cold Formed Steel Structural Members.

D. American Society for Testing Materials (ASTM):

1. ASTM - Standard Specifications for Properties of Materials.

E. American Wood Council (AWC):

1. ANSI/AWC NDS (National Design Specification for Wood Construction).

F. American Welding Society (AWS):

1. AWS D1.1 Structural Welding Code – Steel

2. AWS D1.3 Structural Welding Code - Sheet Steel

G. Canadian Welding Bureau: CWB Division 3 W47.1

H. U.S. Architectural & Transportation Barriers Compliance Board's ADA-ABA Accessibility Guidelines.

I. Forest Stewardship Council:

1. Chain of Custody Certification (FSC-STD-40-004)

J. International Building Code (IBC): 2015

K. International Code Council (ICC):

1. ICC 300: Standard for Bleachers, Folding and Telescopic Seating and Grandstands.

2. PS 1: Structural Plywood.

L. Southern Pine Inspection Bureau (SPIB):

1. SPIB: Standard Grading Rules for Southern Pine.

1.3 PERFORMANCE REQUIREMENTS

A. Structural Performance: Engineer, fabricate and install telescopic gym seating systems to the following structural loads without exceeding allowable design working stresses of materials involved, including anchors and connections. Apply each load to produce maximum stress in each respective component of each telescoping stand unit according to ICC 300

B. Manufacturer's System Design Criteria:

1. Gymnasium seat assembly; Design to support and resist, in addition to its own weight, the following forces:

a.) Live load of 120 lbs. per linear foot (1.75 kN/m) on seats and decking b.) Uniformly distributed live load of not less than 100 psf (4.79 kN/m2) of gross horizontal projection.

c.) Parallel sway load of 24 lbs. per linear foot (0.35 kN/m) of row combined with (b.) above d.) Perpendicular sway load of 10 lbs. per linear foot (0.15 kN/m) of row combined with uniformly distributed live load above.

e.) Parallel and Perpendicular sway loads are not applied concurrently.

2. Hand Railings, Posts and Supports: Engineered to withstand the following forces applied separately:

a.) Concentrated load of 200 lbs. (0.89 kN) applied at any point and in any direction.

b.) Uniform load of 50 lbs. per foot (0.73 kN/m) applied in any direction.

3. Guard Railings, Post and Supports: Engineered to withstand the following forces applied separately:

a.) Concentrated load of 200 lbs. (0.89 kN) applied at any point and in any direction along top rail.

b.) Uniform load of 50 lbs. per foot (0.73 kN/m) applied in any direction at top rail c.) Uniform load of 50 lbs. (0.22 kN) applied on an area equal to 1 ft2 (0.09 m2) applied on all guardrail infill panels.

1.4 ACTION SUBMITTALS

A. Product Data: For each type of product indicated.

B. Shop Drawings: For telescoping stands in both stacked and extended positions. Show seat heights, row spacing and rise, aisle widths and locations, assembly dimensions, anchorage to supporting structure, material types and finishes.

1. Electrical: Indicate power supply requirements.

C. Samples: For units with factory-applied finishes.

1.5 INFORMATIONAL SUBMITTALS

A. Qualification Data: For qualified manufacturer and installer.

B. Welding certificates.

C. Product Test Reports: Load test to all loads, observed by a qualified independent testing laboratory, and certified by a registered professional structural engineer verifying the integrity of the manufacturer's design.

D. Warranty: Manufacturers standard warranty documents.

1.6 CLOSEOUT SUBMITTALS

A. Operation and Maintenance Data: For telescopic bleacher to include video operations manual.

1.7 QUALITY ASSURANCE

A. Manufacturer's Qualifications: A minimum of 40 years of experience manufacturing telescoping stands and can demonstrate continual design enhancement and 25-year minimum product life-cycle support of telescopic seating.

B. Installer Qualifications: Factory certification by the manufacturer.

1. Project list: Ten projects of similar size, complexity and in service for at least five years.

C. Welding Qualifications: Qualify procedures and personnel according to AWS D1.3, "Structural Welding

Code - Sheet Steel."

D. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application.

Below standard may be more stringent than applicable building code requirements. Coordinate with local building code requirements for telescoping stands.

E. Seating Layout: Provide telescoping stands to comply with ICC 300 <2017> Standard for Bleachers, Folding and Telescopic Seating, and Grandstands, except where additional requirements are indicated or imposed by authorities having jurisdiction.

1.8 DELIVERY, STORAGE AND HANDLING

A. Deliver telescoping stands in manufacturers packaging clearly labeled with manufacturer name and content.

B. Handle bleacher equipment in a manner to prevent damage.

C. Deliver the telescoping stands at a scheduled time for installation that will not interfere with other trades operating in the building when at all possible.

1.9 PROJECT CONDITIONS

A. Field Measurements: Coordinate actual dimensions of construction affecting telescoping stands installation by accurate field measurements before fabrication. Show recorded measurements on final shop drawings. Coordinate field measurements and fabrication schedule with construction progress to avoid delay of Work.

1.10 WARRANTY

A. Manufacturer's Warranty: Includes the repair or replacement of the defective product; or defective component thereof, with a comparable product; or component thereof, or a refund of the purchase price prorated over the warranty period.

1. Includes: Labor, materials, and freight for replacement or repairs.

2. Structural Component parts of Understructure Warranty Period: [10 years] from Date of Acceptance

3. Decking systems, seating collections, electrical, portable and integral dolly systems, end closure curtains, surface material finishes Warranty Period [5 years] from Date of Acceptance.

PART 2 PRODUCTS

A. Wood:

1. Lumber: NIST PS 20, southern pine complying with SPIB's "Standard Grading Rules for Southern

Pine Lumber" for B&B Finish (B and better) grade-of-finish requirements.

2. Plywood: NIST PS 1, APA-grade trademarked, A-C grade.

B. Steel:

1. Structural-Steel Shapes, Plates, and Bars: ASTM A36.

2. Galvanized-Steel Sheet: ASTM A653, coating designation G60.

3. Uncoated Steel Strip; Non-Structural Components: ASTM A1011, Commercial Quality, Type B, Hot-

Rolled Strip.

4. Uncoated Steel Strip; Structural Components: ASTM A1011 Grade 33 (228 MPa), Grade 36 (249

MPa), Grade 40 (276 MPa), Grade 45 (311 MPa), or Grade 50 (345 MPa), Structural Quality, Hot-

Rolled.

5. Galvanized Steel Strip: ASTM A653 Grade 40 (276 MPa), structural quality, coating designation

G60.

6. Tubing: ASTM A500, cold formed; Grade B.

C. Polyethylene Plastic: High-density polyethylene; injection molded, color-pigmented, textured, impact-resistant, and dimensionally stable.

2.2 MANUFACTURERS

A. Manufacturer (Basis of Design): Hussey Seating Company, U.S.A.

1. Address: North Berwick, Maine, 03906.

2. Telephone: (207) 676-2271; Fax: (207) 676-9690.

3. Product: MAXAM Telescopic Gym Seat System.

B. Manufacturer: Interkal Spectator Seating Worldwide

1. Address: 5981 East Cork, Kalamazoo, MI 49048

2. Telephone: (269) 349-1521; Fax: (269) 349-6530.

3. Product: Forward-Fold Wall-Attached System

C. Substitutions: see project manual for instructions

2.3 TELESCOPING STANDS

A. Wall-Attached Telescoping Stands: Forward-folding system with the rear of the understructure permanently attached to the floor and to the rear wall. Rear wall provides structural support and must support loads imposed by the bleacher.

2.4 DIMENSIONAL AND OPERATIONAL CRITERIA

A. Dimensions:

1. Bank Lengths: 96’6”.

2. Number of Tiers: 10

3. Row Spacing: 24 inches (660 mm).

4. Row Rise: 9-5/8 inches (244 mm).

B. Operation: Integral Power

C. All integral powered options operate the entire bank.

1. Integral Power: Pendant control unit.

a.) Limit Switches: Automatically stop integral power system when telescoping stands reach fully opened or closed positions.

2.5 SEATING

A. Polymer Seat System: Courtside Collection XC10

1. Material: Gas assist injection-molded, 100 percent recyclable HDPE, high density polyethylene.

2. Module Size: 18 inches (457 mm) long by 10 inches (254 mm) deep.

3. Module Load: Tested to 600 lbs. (2.67 kN).

4. Integrally molded end caps at aisle end locations.

5. Integrally molded recess pockets to accept seat number and row letters.

6. Integrally molded rear closure panel at back of seat to allow for "continuous clean sweep" of debris at deck level and minimized visibility of structural ribbing.

7. Color: As selected by Architect from manufacturers 15 standard colors

B. ADA Accessible Seating:

1. Locate first tier modular units to provide wheelchair-accessible seating at locations indicated on

Drawings.

a.) Flex-RowTM: Provide first row modular recoverable seating units that can be closed to accommodate persons requiring ADA spaces (or any other temporary space needs) or opened for standard usage. Each Flex-Row unit shall have a handle for easy operation.

b.) Provide a black full-surround steel skirting with no more than ¾” floor clearance for safety and improved aesthetics.

1.) Provide a black injection molded end cap for the nose beam for safety and improved aesthetics.

2.) Provide a mechanical positive lock when the Flex-Row system is in both the open and closed position. Handle shall unlock the modular recoverable seating unit for operation.

3.) Flex-Row can be utilized with the full system in the open or closed position.

4.) Flex-Row modular units are designed to achieve multi-use front row seating to accommodate team seating, ADA requirements and facility specific requirements. Flex-Row units are available in modular units from 2 to 7 seats wide as well as full section widths.

2.6 RAILS, PANELS AND STEPS

A. End Rails:

1. Self-storing a.) Provide steel self-storing starting no higher than tier 2 [42 inches (1066mm)] high above seat, end rail with tubular supports and intermediate members designed with [4 inch (102mm)] sphere passage requirements.

2. Material and Finish: powder coated steel.

3. Color: Black

B. Center Aisle Rails:

1. Auto-Rotating a.) Provide single pedestal mount handrails [34 inches (864mm)] high with terminating mid rail.

Permanently attached handrail shall rotate in a permanently mounted socket for rail storage. Rail shall automatically rotate, lock in the use position, unlock and rotate back to the stowed position as the gym seats open and close. Ends of the handrail shall return to the post, and not extend away from it. Rails having openings to avoid interference with closed decks are not acceptable

2. Material and Finish: powder coated steel.

3. Color: Black.

C. Skirt Panel: On 1st Row, provide galvanized steel front skirt panel to prevent players/objects from sliding underneath the first row.

D. Steps

1. Removeable Front Aisle Steps: At each vertical aisle location front aisle step. Front steps shall engage with front row to prevent accidental separation or movement. Provide four non-skid rubber feet each

[1 inch (25 mm)] in diameter. Full radius end caps on all four edges.

2. Intermediate Aisle Steps: Fully enclosed, at each vertical aisle. Full radius end caps on all four edges.

Adhesive-backed abrasive non-slip tread surface.

2.7 COMPONENTS

A. Decking

1. Plywood a.) 5/8 inch (16 mm) thick AC grade tongue and groove Southern Yellow Pine with clear urethane, high gloss finish.

B. Understructure:

1. Finish: Rust-inhibiting black finish

2. Hardware finish: Zinc-plated, Rust inhibiting black finish

3. Posi-locks and other surfaces: Powder coated black, Rust inhibiting black finish

4. Nose beam and Rear Riser beam: Nose beam shall be continuously roll-formed closed tubular shape of ASTM A653 grade 40 (276 MPa). Riser beam shall be continuously roll-formed of ASTM A653 grade 40 (276 MPa). Nose and Riser beam shall be designed with no steel edges exposed to spectator after product assembly. Nose beam and riser beams are through-bolted fore/aft to deck stabilizers and frame cantilevers to create the deck structure.

5. Frame: The frames are welded assemblies (one left hand, one right hand per tier) comprised of the following components:

a.) Lower Track subassembly: ASTM A1011 Grade 50: Continuous Positive Interglide System

(casterhorn) interlocks each adjacent frame casterhorn using an integral, continuous, anti-drift feature and captive interlock with adjustable row spacing at front to prevent separation and misalignment.

b.) Lower Track Wheels: 3 per frame Not less than [5 inches (127 mm)] diameter by [1-1/4 inches

(32 mm)] with non-marring soft rubber face to protect wood and synthetic floor surfaces, with molded-in sintered iron oil-impregnated bushings to fit [3/8 inch (10 mm)] diameter axles secured with E-type snap rings.

1.) Option: up to 6 wheels per frame for load distribution c.) Slant Columns: A500 Grade B, tubular shape.

d.) Cantilever Subassembly: Consists of ASTM A1011 Grade 50 nose connection plate, cantilever, and riser attachment plate welded together into a subassembly.

6. Lock system: Casterhorns at the end sections of powered banks (minimally), and manual sections, contain a Low Profile Posi-Lock LX to lock each row in open position and allow unlocking automatically. Provide adjustable stops to allow field adjustment of row spacings.

7. Sway Bracing: ASTM A653 grade 40 (276 MPa), tension members bolted to columns.

8. Deck Stabilizer: A1011 Grade 45, member through-bolted to nose and riser at three locations per section. Securely captures front and rear edge of decking at rear edge of nose beam and lower edge of riser beam for entire length of section. Interlocks with adjacent stabilizer on upper tier using low-friction nylon roller to prevent separation and misalignment.

C. Fasteners: Vibration proof, in manufacturer's standard size and material.

1. Finish: Rust-inhibiting black finish

2. Hardware finish: Zinc-plated, Rust inhibiting finish

3. Posi-locks and other surfaces: Powder coated black, Rust inhibiting black finish

4. Nose beam and Rear Riser beam: Nose beam shall be continuously roll-formed closed tubular shape of ASTM A653 grade 40 (276 MPa). Riser beam shall be continuously roll-formed of ASTM A653 grade 40 (276 MPa). Nose and Riser beam shall be designed with no steel edges exposed to spectator after product assembly. Nose beam and riser beams are through-bolted fore/aft to deck stabilizers and frame cantilevers to create the deck structure.

5. Frame: The frames are welded assemblies (one left hand, one right hand per tier) comprised of the following components:

a.) Lower Track subassembly: ASTM A1011 Grade 50: Continuous Positive Interglide System

(casterhorn) interlocks each adjacent frame casterhorn using an integral, continuous, anti-drift feature and captive interlock with adjustable row spacing at front to prevent separation and misalignment.

b.) Lower Track Wheels: 3 per frame Not less than [5 inches (127 mm)] diameter by [1-1/4 inches

(32 mm)] with non-marring soft rubber face to protect wood and synthetic floor surfaces, with molded-in sintered iron oil-impregnated bushings to fit [3/8 inch (10 mm)] diameter axles secured with E-type snap rings.

1.) Option: up to 6 wheels per frame for load distribution c.) Slant Columns: A500 Grade B, tubular shape.

d.) Cantilever Subassembly: Consists of ASTM A1011 Grade 50 nose connection plate, cantilever, and riser attachment plate welded together into a subassembly.

6. Lock system: Casterhorns at the end sections of powered banks (minimally), and manual sections, contain a Low Profile Posi-Lock LX to lock each row in open position and allow unlocking automatically. Provide adjustable stops to allow field adjustment of row spacings.

7. Sway Bracing: ASTM A653 grade 40 (276 MPa), tension members bolted to columns.

8. Deck Stabilizer: A1011 Grade 45, member through-bolted to nose and riser at three locations per section. Securely captures front and rear edge of decking at rear edge of nose beam and lower edge of riser beam for entire length of section. Interlocks with adjacent stabilizer on upper tier using low-friction nylon roller to prevent separation and misalignment.

2.8 ELECTRICAL OPERATION SYSTEMS

A. Integral Power

1. Default operation shall be with a removable pendant control unit which plugs into seating bank for tethered operator management of stop, start, forward, and reverse control of the power operation.

Other modes of operation are optional.

B. PF 2: Furnish and install Hussey PF 2, an integral automatic electro mechanical powered frame propulsion system, to open and close telescopic seating.

1. Electrical - Seating Manufacturer shall provide all wiring within seating bank, including pendant control. Motors, housing, and wiring shall be installed and grounded in complete accord with the

National Electrical Code. The control system shall operate at low voltage (24V). The electrical contractor shall perform all connections at and upstream of the equipment specified herein and ensure that supplied voltage drops no more than 4% below nominal where power connects thereto.

2. Each unit for PF 2 is driven by a 1/2 horsepower, 1725 RPM motor.

a.) 208V 3 Phase:

1.) This 1.25 Service Factor motor runs on 208V at 60 Hz and draws a full load current of 1.8 amperes. The required power supply shall be 3 asynchronous phases of 120 Volts each, plus neutral plus ground, each with 20 Amp capacity.

2.) This system shall be UL Listed in its entirety (motors, circuit protection, motor controls, user interface, enclosures, conductors and connectors all evaluated and approved for correct sizing and compatibility under maximum rated load on the motors) under UL Product Category

FHJU, titled Electrical Drive and Controls for Folding and Telescopic Seating.

b.) Each pair of Powered Frames shall consist of output shaft gear reducer with [6 inch (152mm)] diameter x [4 inch (102mm)] wide wheels covered with non-marring [1/2 inch (13mm)] thick composite rubber, and operate the bleacher as follows:

1.) PF2 – Pulls at 46 feet / min [16.8 meters / min] with ½ Hp through 60:1 speed reduction to 4 drive wheels. Max pull approx 261 lbs [1161 N];

2.9 FABRICATION

A. Fabricate understructure from structural-steel members in size, spacing, and form required to support design loads specified in referenced safety standard.

B. Weld understructure to comply with applicable AWS standards.

C. Round corners and edges of components and exposed fasteners to reduce snagging and pinching hazards.

D. Form exposed sheet metal with flat, flush surfaces, level and true in line, and without cracking and grain separation.

2.10 ACCESSORIES

A. Vinyl Curtain End Closures at all banks

2.11 GRAPHICS

A. Xtreme Graphic Logo The Xtreme Graphic Logo is comprised of decorative artwork and/or text that has been permanently bonded to the front vertical surface of the bleacher seat modules. The artwork is tiled, a process whereby a single large graphic is segmented and applied in separate parts to individual seat modules, which, when viewed together as a whole become a unified piece of artwork, similar to a mosaic.

The graphics are printed as full color CMYK pigmented resin and adhesive layer onto a 100UM polyester clear glossy release film (transfer sheet). The application process uses a combination of heat and pressure to activate the adhesive and permanently bond the resin to the HDPE seat module. Once applied, the graphic cannot be removed from the seat module without damaging or destroying the seat module surface.

Customer must provide vector-based digital artwork, and approved layout indicating tiled application to individual seat modules to be provided with bid.

B. Factory or Dealer designed logo that incorporates school letters or graphical representation of school logo across the front of the bleachers.

1. Logo is visible when the bleachers are in the stored position.

2. Select up to three colors for maximum color contrast and creativity.

PART 3 EXECUTION

3.1 EXAMINATION

A. Examine areas where telescoping stands are to be installed, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of the Work.

B. Proceed with installation only after unsatisfactory conditions have been corrected.

3.2 INSTALLATION

A. Tolerances:

1. Flooring [and rear wall]: Level [and plumb] within [1/8 inch (3 mm)] in [8 feet (2438mm)].

2. Maximum bleacher force on the floor of a [27 foot (8230 mm)] section: Static point load of less than

300 psi (2068 kN/m2).

B. Install telescoping stands to comply with referenced safety standard and manufacturer's written instructions.

3.3 ADJUSTING AND CLEANING

C. On completion of installation, lubricate, test, and adjust each telescoping stand unit so that it operates according to manufacturer's written operating instructions.

D. Clean installed telescoping stands on exposed surfaces. Touch up shop-applied finishes or replace components as required to restore damaged or soiled areas.

3.3 MAINTENANCE SERVICE

A. Service Capability: Show proof of full-time service capability by factory certified technicians directly employed by the installer.

1. A four to eight-hour maximum on-site repair response is required during normal working hours, 8 a.m.

to 5 p.m. weekdays (excluding holidays).

2. All Full Time Service Personnel shall be Factory Authorized and Trained.

3. Provide proof of Service Capability and a list of service parts regularly maintained in inventory.

3.4 DEMONSTRATION

Engage a factory-authorized service representative to train Owner's maintenance personnel to adjust, operate, and maintain telescoping stands.

END OF SECTION 126613