The file is a scrub file (Excel spreadsheet) and an Invitation for Bids (IFB) for the District of Columbia Department of General Services (DGS) involving epoxy flooring upgrades for four Fire and Emergency Medical Services (FEMS) engine houses. The project will replace epoxy flooring at Engine Houses #1, 11, 16, and 29, located in various Northwest Washington, D.C. locations, with building square footages ranging from 13,363 to 25,634 square feet and construction/renovation dates between 1925 and 2017. The solicitation is specifically set aside for certified Small Business Enterprises (SBEs) through the District of Columbia Department of Small and Local Business Development (DSLBD).

The contract requires contractors to provide all labor, materials, and equipment for comprehensive flooring upgrades, with the scrub file detailing potential work across multiple construction divisions including general requirements, existing conditions, concrete, masonry, finishes, and electrical work. The bid is structured as a local government contract with specific requirements for small business participation, focusing on epoxy flooring replacement and potential associated renovations. While the scrub file shows no specific dollar amounts, the project involves multiple engine house locations and potentially comprehensive facility improvement work beyond just flooring replacement. The solicitation emphasizes local business development by restricting bidding to certified small businesses within the District of Columbia.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Scrub File-DCAM-25-CS-IFB-0006
FEMS: Epoxy Flooring Replacement for E1, E11, E16 and E29
DESCRIPTIONProposalCapitalLocalComments
Division 01General Requirements$ - 0$ - 0$ - 0
General Conditions$ - 0
Project Management$ - 0
Project Superintendent$ - 0
Architect
Permits & Fees$ - 0
Division 02Existing Conditions$ - 0$ - 0$ - 0
Temporary Protection$ - 0
Demolition$ - 0
Temporary Swing Space Preparation$ - 0$ - 0$ - 0
Division 03Concrete$ - 0$ - 0$ - 0
Furnish & install 4-inch concrete pad$ - 0
$ - 0$ - 0$ - 0
Division 04Masonry$ - 0$ - 0$ - 0
Provide masonry/mortar patchwork and repairs around any exterior wall penetrations$ - 0
$ - 0
Division 05Metals$ - 0
Metal Deck$ - 0$ - 0$ - 0
Ornamental Metals$ - 0$ - 0$ - 0
Division 06Wood, Plastics, Composites$ - 0$ - 0$ - 0
Rough Carpentry
Interior Trim
Plywood Backing Panels
Finish Carpentry
Division 07Thermal and Moisture Protection$ - 0$ - 0$ - 0
Rigid Insulation$ - 0
Thermal Wrap$ - 0
Vapor Retarders$ - 0
Division 08Openings$ - 0$ - 0$ - 0
Doors, Frames & Hardware
Division 09Finishes$ - 0$ - 0$ - 0
Wall Mounted Cabinets$ - 0
Base Cabinets/Drawers$ - 0
New Wall Cabinet with Doors$ - 0
Epoxy flooring coating (with resin)
Division 10Specialties$ - 0
Toilet Partitions$ -0$ - 0
Lockers$ - 0
Bathroom Accessories$ - 0
Division 11Equipment$ - 0$ - 0$ - 0
Microwave
Coffee Maker
Six (6) Burner Range w/ Wheels
Training Monitor & Monitor Wall Mount
Whiteboard
Small Kitchen Equipment & Utensils
Pre-Rinse Spray & Faucet
Base Cabinet w/ Solid Surface
Magnetic Knife Holder
Ice Machine
Dishwasher
Refrigerator Five (5)
Division 12Furnishings$ - 0$ - 0$ - 0
New Training Table
One (1) Desk and One (1) Chair
Custom Table and Eight (8) Chairs
Division 22Plumbing$ -0$ -0$ -0
104 Kitchen Plumbing$ - 0
101 Common Area$ - 0
103 Toilet$ - 0
Apparatus Bay$ - 0
Division 23HVAC$ - 0$ - 0$ - 0
103 Kitchen HVAC$ - 0
101 Common Area$ - 0
103 Toilet Room Ventilation$ - 0
Division 26Electrical$ - 0$ - 0$ - 0
Furnish & install all new required switches, slide dimmers, outlets, conduit and connections$ - 0
Furnish and install new electrical outlets Ground Fault Circuit Interrupter (GFI) and covers (1:1 replacement).$ - 0
Division 27Communications
Division 28Electronic Safety and Security
Grand Total$ - 0$ - 0$ - 0

File details come from the government source that posted it. Updated .