S02 - Single Source Justification_Door Hardware.pdf
PDF 673 KB Posted
- Solicitation number
- 36C25222B0030
About this file
This document contains a single source justification for a federal construction project. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 12 requires door hardware including Sargent locksets, Medeco cores, LCN closers, Von Duprin exit devices, and Hager hinges for Building 112 upgrades at the Clement J. Zablocki Medical Center. Using other brands would be more expensive and time consuming due to duplicating stocking efforts, training, and maintaining separate keying systems. Market research found other hardware is inferior and incompatible with standards. The justification cites ensuring quality, compatibility, and cost effectiveness as reasons for limiting competition to these approved facility standards for the estimated $10,000 contract.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25222B0030 0007.docx | DOCX document | |
| S06 - SOW Updated Rev02_10.14.22.pdf | ||
| 36C25222B0030 0006.docx | DOCX document | |
| S06 - Wage Determination_10.14.22.pdf | ||
| 36C25222B0030 0005.docx | DOCX document | |
| 36C25222B0030 0004.docx | DOCX document | |
| S06 - SOW - Updated_10.3.2022.pdf | ||
| S06 - Wage Determination_8.5.2022.pdf | ||
| 36C25222B0030 0003.docx | DOCX document | |
| S06 - Specification 31 62 16 HELICAL PIERS - ADDED.pdf | ||
| S06 - Drawing A-001 Revised.pdf | ||
| S06 - Spedification 26 32 13 ENGINE GENERATORS - UPDATED.pdf | ||
| S06 - Geotechnical Report - ADDED.pdf | ||
| S06 - Specification 01 91 00 COMMISSIONING REQUIREMENTS - ADDED.pdf | ||
| 36C25222B0030 0002.docx | DOCX document | |
| S04 - Site Visit Sign-In Sheet.pdf | ||
| 36C25222B0030 0001.docx | DOCX document | |
| S02 - Single Source Justification_Fire Alarm System.pdf | ||
| S02 - Davis Bacon WD.pdf | ||
| S02 - Drawings.pdf | ||
| 36C25222B0030.docx | DOCX document | |
| S02 - Specifications.pdf | ||
| S02 - Single Source Justification_HID MultiClass Readers.pdf |
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VHAPG Part 813.106 Simplified Acquisition Procedures: Soliciting from a Single Source Attachment 1: Single Source Justification for SAP under the SAT
Last Updated: 02/01/22 Page 1 of 1
DEPARTMENT OF VETERANS AFFAIRS
Justification for Single Source Awards IAW FAR 13.106-1 For
Over Micro-Purchase Threshold but Not Exceeding the SAT ($250K)
Acquisition Plan Action ID:___ 36C252-22-AP-3493_
1. Contracting Activity: Department of Veterans Affairs, VISN 12, Clement J. Zablocki Medical Center, NCO 12 Construction Team 695-22-4-6970-0009.
2. Brief Description of Supplies/ Services required and the intended use/Estimated Amount:
These products, Sargent 11 Series T-zone cylindrical lockset and Sargent 8200 series Mortise Locksets with Medeco 7-pin interchangeable cylindrical cores, LCN Closers (Mechanical, Electronic Hold-Open, Electromagnetic), Von Duprin Exit Devices and Hager Hinges are facility standards. It would be extremely cumbersome and expensive to maintain a completely separate locking systems./ $10,000
3. Unique characteristics that limit availability to only one source, with the reason no other supplies or services can be used:
The medical center requires all construction incorporate the Sargent Locksets and Medeco keying system, LCN Closers (Mechanical, Electronic Hold-Open, Electromagnetic), Von Duprin exit devices and Hager hinges because experience has found out that “approved equals” are not at all equal in quality. It is also important to note that maintaining bench stock for the parts and keying components of an entirely different locking system and hardware sets would be expensive and time-consuming. Use of another brand would require duplicating efforts in training and double the stock on hand for replacement parts. These items are competitively priced and are widely available.
4. Description of market research conducted and results or statement why it was not conducted:
We have conducted research into other hardware and have found that it is inferior and not compatible with our standard. The other products on the market would require additional cost to maintain within the facility.
5. Contracting Officer's Certification: Purchase is approved in accordance with FAR13.106-1(b). I certify that the foregoing justification is accurate and complete to the best of my knowledge and belief.
Name Date Title
Ryan J Mcmillin 694313
Digitally signed by Ryan J Mcmillin 694313 Date: 2022.07.20 06:20:45 -05'00'
ACCOMPANYING SOLICITATION 36C25222B0030
File details come from the government source that posted it. Updated .