S02-Security Unit Price List FSL II Exhibit I.pdf

PDF 189 KB Posted

Attached to
X1AA--36C249-26-AP-0006 - Frankfort CBOC Lease 2. 0 (Lex Med Ctr)
Solicitation number
36C24926R0002
Issued by

About this file

This document is a Security Unit Price List (Level II) form for a federal lease, designed to capture security-related costs and requirements for a government facility. The form comprehensively details security standards across seven main sections: facility entrances and areas, interior government space, building exterior and sites, security systems, structure, operations/administration, and cybersecurity. Many line items are designated as "Priced in Shell," indicating these costs are included in the base building lease price, while some specific security measures require unit pricing, such as video surveillance system installation, intrusion detection system design, and security systems design. The Building Specific Amortized Capital (BSAC) amount represents an estimate of potential security countermeasures, with actual costs to be determined after final design and subject to further negotiation prior to a Notice to Proceed. The form is intended to be filled out post-award and includes placeholders for lease number, client name, city, and state.

View the file

Other files

File Type Posted
Question 3 36C249-26-AP-0006 - Frankfort CBOC Lease 2.0 ASR Questions and Request for Extension.pdf PDF
Question 2 36C249-26-AP-0006 - Frankfort CBOC Lease 2.0 ASR Questions.pdf PDF
Question 1 36C249-26-AP-0006 - Frankfort CBOC Lease 2.0 ASR Questions and Request for Extension.pdf PDF
S02-RLP 36C24926R0002 Revised.pdf PDF
S02 - 3516 Solicitation Provisions Exhibit D.pdf PDF
S02-3517B General Clauses Exhibit E.pdf PDF
S02- FORM 1364 INSTRUCTIONS Exhibit F2.pdf PDF
S02- Fire and Safety 12000 Exhibit H.pdf PDF
S02-Tenant Improvements Cost Summary TICS Table Exhibit L.pdf PDF
S02 Past Performance Questionnaire Exhibit N.pdf PDF
S02 Small Business SubCon Plan Exhibit O.pdf PDF
S02-Architect and Engineering qualifications SF330 Exhibit P.pdf PDF
S02-RLP 36C24926R0002 .pdf PDF
S02-Lease Agreement 36C24926R0002 Exhibit A.pdf PDF
S02- VA Security Requirements FSL Level II Oct 2024 Exhibit C.pdf PDF
S02-DOL Wage Determination Exhibit K.pdf PDF
S02-Form 1364 Proposal to Lease Space Exhibit F.pdf PDF
S02- Rent Chart For Form 1364 Exhibit F1.pdf PDF
S02 Form 1217 Exhibit G.pdf PDF
S02-Seismic Forms A - F with Instructions Exhibit J.pdf PDF
S02-FAR 52.204-24 Representation Digital Exhibit M.pdf PDF
Deliniated Map.pdf PDF
S02-Agency Space Requirement - Frankfort CBOC Exhibit B.pdf PDF
Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Lease Security Standards Section Unit Price Quantity Total

I. FACILITY ENTRANCES, LOBBY, COMMON AREAS, NON-

PUBLIC, AND UTILITY AREAS

A. FACILITY ENTRANCES AND LOBBY

1. EMPLOYEE ACCESS CONTROL AT ENTRANCES (SHELL) Priced in Shell

B. SCREENING REQUIREMENTS

1. ACCOMODATION OF RETAIL/MIXED USE SPACE (SHELL) Priced in Shell

C. COMMON AREAS, NON-PUBLIC, AND UTILITY AREAS

1. PUBLIC RESTROOM ACCESS (SHELL) Priced in Shell

2. SECURING CRITICAL AREAS (SHELL) Priced in Shell

3. VISITOR ACCESS CONTROL (SHELL) Priced in Shell

4. PUBLIC SPACE RESTRICTIONS WITH PRIMARY VERTICAL LOAD

MEMBERS -$

4a. RESTRICT CONTACT FROM PUBLIC AREAS WITH PRIMARY VERTICAL

LOAD MEMBERS -$

4b. RESTRICT CONTACT FROM MAIL AREAS WITH PRIMARY VERTICAL LOAD

MEMBERS -$

II. INTERIOR (GOVERNMENT SPACE)

A. IDENTITY VERIFICATION (SHELL) Priced in Shell

B FORMAL KEY CONTROL PROGRAM (SHELL) Priced in Shell

III. SITES AND EXTERIOR OF THE BUILDING

A. SIGNAGE

1. POSTING OF SIGNAGE IDENTIFYING THE SPACE AS GOVERNMENTAL

(SHELL) Priced in Shell

2. POSTING OF REGULATORY SIGNAGE (SHELL) Priced in Shell

B. LANDSCAPING AND ENTRANCES

1. LANDSCAPING REQUIREMENTS (SHELL) Priced in Shell

2. HAZMAT STORAGE (SHELL) Priced in Shell

The Building Specific Amortized Capital (BSAC) amount under the Lease represents an estimate of the possible countermeasures outlined under the Security Requirements section of the lease. The actual BSAC amount shall be determined after the final design. Using this form, the Lessor shall quote unit prices on all security countermeasures identified in the Lease, as reflected in the final Design Intent Drawings (DIDs) and Construction Documents (CDs). These unit costs shall be subject to further negotiation, prior to issuance of a 'Notice To Proceed' for the security improvements. Refer to 'Security Standards' attachment to the Lease for additional details. Input 'Unit Price' and 'Quantity' figures for BSAC items (light blue) and the total will automatically be calculated for that row. Items designated as 'Priced in Shell', 'Priced in Tenant Improvements', or 'Government Provided' are included on this form to align with the full requirements of the 'Security Standards' attachment, but should not be priced on this document. SHELL and TI costs should be included on a 'TICS' form if one has been provided by the Government. Lease-specified overhead fees on the BSAC amount can likewise be calculated on the TICS form by transferring the BSAC 'Total Costs' calculated at the bottom of this worksheet to the TICS form according to the instructions on that document.

LEASE NUMBER [INSERT LEASE #]

[INSERT CLIENT NAME]

[INSERT CITY and STATE]

To be filled out post-award

SECURITY UNIT PRICE LIST (FSL II)

[INSERT DATE]

INSTRUCTIONS TO THE LEASING SPECIALISTS: THIS SPREADSHEET REFLECTS THE BASELINE SET OF SECURITY PARAGRAPHS. EACH PARAGRAPH IN THE SECURITY SECTION WILL HAVE A CORRESPONDING LINE. IF THE SECURITY SECTION IS ADJUSTED BY ADDING OR DELETING PARAGRAPHS THE SPREADSHEET MUST BE CHANGED

ACCORDINGLY.

Security Unit Price List (Level II)

REV (OCT 2024)

Exhibit I

3. PLACEMENT OF RECEPTACLES, CONTAINERS, AND MAILBOXES (SHELL) Priced in Shell

C. PARKING

1. PUBLIC ACCESS TO GOVERNMENT PARKING AREAS (SHELL) Priced in Shell

IV. SECURITY SYSTEMS

A. SECURITY SYSTEM TESTING & MAINTENANCE CRITERIA -$

B. VIDEO SURVEILLANCE SYSTEM (VSS)

LESSOR PROVIDED DESIGN AND INSTALLATION -$

GOVERNMENT PROVIDED SCOPE, PRODUCT, AND INSTALLATION Government Provided

C. INTRUSION DETECTION SYSTEM

LESSOR PROVIDED DESIGN AND INSTALLATION -$

GOVERNMENT PROVIDED SCOPE, PRODUCT, AND INSTALLATION Government Provided

D. DURESS ALARM

LESSOR PROVIDED DESIGN AND INSTALLATION -$

GOVERNMENT PROVIDED SCOPE, PRODUCT, AND INSTALLATION Government Provided

E. SECURITY SYSTEMS DESIGN -$

V. STRUCTURE

A. WINDOWS

LOCK GROUND FLOOR WINDOWS (BSAC- IDS Monitoring) -$

B. BUILDING SYSTEMS

1. EMERGENCY GENERATOR PROTECTION (T.I.) Priced in Tenant Improvements

2. SECURE AIR INTAKE GRILLES -$

VI. OPERATIONS AND ADMINISTRATION

A. FACILITY SECURITY COMMITTEE (FSC) - (SHELL *) Priced in Shell

B. ACCESS TO BUILDING INFORMATION (SHELL *) Priced in Shell

C. CONSTRUCTION SECURITY PLAN (SHELL) Priced in Shell

VII. CYBERSECURITY (SHELL *)

CYBERSECURITY REQUIREMENTS OUTLINED IN SECTIONS A-C (SHELL *) Priced in Shell

TOTAL COSTS $ -

Security Unit Price List (Level II)