This document is a compilation of product submittals and specification sheets for building materials and fixtures.
The document contains technical submittals for HVAC diffusers and grilles from TITUS, a manufacturer of air distribution products. The AG-35-B duct-mounted opposed blade damper submittal describes a minimum security diffuser (Model SG-TDC) featuring a steel louvered core with lattice face plate, designed for areas requiring security measures while maintaining maximum performance. The unit accommodates duct dimensions from 6" to 24" in 3" increments, utilizes 12-gauge steel face plates with 13/16" square holes and 3/16" fret bars, and includes specifications for rear angle frames, screw hole locations, and mounting hardware. An additional TITUS submittal covers the SG-1500 minimum security grille—an aluminum fixture with fixed bars and zero-degree deflection louvers designed for shower areas and humid environments. This grille is available in widths from 6" to 30" and heights from 4" to 30", with sleeve lengths of 6", 8", 10", 12", or 18".
The document also includes American Standard Lucerne wall-hung lavatory specification sheets providing detailed dimensional drawings and roughing-in information for multiple faucet hole configurations (8" centers, 4" centers, and single center), along with barrier-free accessibility compliance details meeting ADA guidelines with mounting heights set at 864mm (34") above finished floor. Finally, a Chicago Faucets mechanical faucet submittal (Model 895-317GN2FCAB) describes a deck-mounted 4" fixed center hot and cold water sink faucet with a 5-1/4" gooseneck spout, 4" wristblade handles, 1.5 GPM laminar flow control, ECAST brass construction with lead content below 0.25%, and compliance with ASME A112.18.1/CSA B125.1 and NSF/ANSI 61 standards.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F2
B4
B3
E3
A4 Square
4 Way
2 Way
2 Way
3 Way
Corner
E2
Y
X
Y
X 2Y<
X
Y
A3-2
A3
X Y, X Y_>
X
X
Y core option.
For B3, X = 2Y
For E3, X > 2Y
For A3, X > Y longer dimension for each
Dimension X is always the available in 3" increments.
available rectangular duct here are the proportions of
Dimensions X and Y shown
For A3-2, X > Y, X < 2Y sizes. Duct sizes are
Y
G2 Square
Y
Y
X
X
X
X 2Y
X 2Y
S2 Square
1 Way
A1
A2
S1 Square
B2
B1
Submittal
AG-35-B Duct-Mounted Opposed Blade Damper
Standard Finish: #26 White
General Description
· The TITUS model SG-TDC is typically used in areas of constant supervision or lobbies or entryways. The
SG-TDC is designed where minimum security is still necessary and maximum performance is required.
This ceiling diffuser assembly utilizes the often specified TITUS TDC diffuser with a heavy gauge steel lattice grille field attached to the diffuser.
· Face Plate is 12 gauge steel with 13/16” square holes and 3/16” fret bars.
· Louvered Diffuser contains TITUS model TDC border
1 (surface mount) with 1, 2, 3 or 4 way blow pattern.
· Screw holes provided in face plate. Tamper proof screws provided by others.
· Cable operated AGR-35-AA damper may be ordered ordered separately from diffuser.
Minimum Security Diffuser
Steel Louvered Core Diffuser with Lattice Face
Model: SG-TDC
SGTDC 1.0 8-12-16
Accessories (Optional) Check if provided.
User Specified Dimensions
Duct Dim A: _____”
Duct Dim B: _____”
Dimension Limitations
Duct Dim A: 6" to 24"
Duct Dim B: 6" to 24"
Available in 3" increments.
Rear Angle Frame
1 ½” x 1 ½” x 3/16” steel angle frame with ¼”-20
NC weld nuts. (Bolts provided by others.)
Ceiling Opening = Duct plus 3 1/2"
Duct
Duct plus 5 9/16"
Duct minus 1/8"
12 Gauge Face Plate 1/4"
2 1/8"
5/16" Dia. Holes1/2"
Duct plus 5 9/16"
3/16" 13/16"
Neck Size Location and # of Holes
6” One hole at center line
9” to 18” Two holes 3” from each edge
21” to 24” Three holes equally spaced
Screw Hole Location per Side
This submittal is meant to demonstrate general dimensions of this product. The drawings are not meant to detail every aspect of the product. Drawings are not to scale. Titus reserves the right to make changes without written notice.
All rights reserved. No part of this work may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or by any information storage retrieval system without permission in writing from Air Distribution Technologies.
Minimum Security Grilles and Registers Aluminum • Fixed Bars
Model: SG-1500FL • 0° De�ection • Long Blade Orientation • 1/2” Spacing
Submittal SG-1500 2-28-13
Angle Frame Shipped Loose for Field Welding 1 1/2” x 1 1/2” x 1/8” aluminum angle iron welded together for field installation. Frame is mill finish.
SG-6.0-S
All rights reserved. No part of this work may be reproduced or transmitted in any form or any means, electronic or mechanical, including photocopying and recording, or by any information storage retrieval system without permission in writing from Air Distribution Technologies
Note: This submittal is meant to demonstrate general dimensions of this product. The drawings on this submittal are not meant to detail every aspect of the product with exactness. Drawings are not to scale. TITUS reserves the right to make changes without written notice.
General Construction
User Speci�ed Dimensions
Duct Width: ________”
Duct Height: ________”
Sleeve Length: ________”
Options and Accessories
Anchor Bars 1/2” diameter aluminum bars, 3” in height. Positioned three inches from back of face plate on top and bottom of sleeve.
Face Operated Damper AG-15-AA aluminum opposed blade damper. Slot operated from face of the grille.
Rear Operated Damper AG-15-AA aluminum opposed blade damper. Slot operated from rear of the grille.
Sleeve Barrier Grille Constructed of 1/2” diameter aluminum bars with maximum 6” opening.
General Description
The TITUS model SG-1500 is a minimum security grille ideal for shower areas. The rust proof construction makes the SG-1500 an excellent choice for exposure to constant humidity or frequent hosing down.
Standard Construction Details
· Sleeve .09” aluminum.
· Finish #26 White.
· All Welded Construction.
· Louvers 3/16” x 3/4” welded aluminum bars with zero degree deflection.
Dimension Limitations
Width: 6” to 30”
Height: 4” to 30”
Sleeve Length:6”, 8”, 10”, 12” or 18”
#04 Mill Finish
605 Shiloh Road • Plano, Texas 75074• 972-212-4800
M19 © 2008 AS America Inc. Revised 2/08
To Be Specified:
❏ Color: ❏ White ❏ Bone ❏ Silver ❏ Black ❏ Linen ❏ Faucet*:
❏ Faucet Finish:
❏ Supplies:
❏ 1-1/4" Trap:
❏ Nipple:
❏ Bracket Support (by others):
❏ Concealed Arms Support (by others):
* See faucet section for additional models available
LUCERNE™
WALL-HUNG LAVATORY
VITREOUS CHINA
LUCERNE™ WALL-HUNG LAVATORY
| • | Wall-hung sink |
| • | Vitreous china |
| • | Front overflow |
| • | D-shaped bowl |
| • | Self-draining deck area with contoured |
| back and side splash shields | |
| • | Faucet ledge |
Faucet holes on 203mm (8") centers (Illus.):
| ❏ | 0356.028 For exposed bracket support | |
| Shown with 4801.862 Amarilis Heritage | ||
| faucet with Triune Cross handles (not included) | ||
| ❏ | 0356.015 For wall hanger (included) or | |
| concealed arms support | ||
| ❏ | 0356.037 For wall hanger (included) or | |
| concealed arms support | ||
| • Extra right-hand hole | ||
| ❏ | 0356.073 For wall hanger (included) or | |
| concealed arms support | ||
| • Extra left-hand hole |
Faucet holes on 102mm (4") centers:
| ❏ | 0355.027 For exposed bracket support | |
| ❏ | 0355.012 For wall hanger (included) or | |
| concealed arms support | ||
| ❏ | 0355.034 For wall hanger (included) or | |
| concealed arms support | ||
| • Extra right-hand hole | ||
| ❏ | 0355.056 For wall hanger (included) or | |
| concealed arms support | ||
| • Extra left-hand hole |
Single center faucet hole (Illus.):
| ❏ | 0356.041 For exposed bracket support | |
| Shown with 1340.000 metering faucet | ||
| (not included) | ||
| ❏ | 0356.421 For wall hanger (included) or | |
| concealed arms support | ||
| ❏ | 0356.137 For wall hanger (included) or | |
| concealed arms support | ||
| • Extra right-hand hole | ||
| ❏ | 0356.115 For wall hanger (included) or | |
| concealed arms support | ||
| • Extra left-hand hole |
Nominal Dimensions:
521 x 464mm (20-1/2" x 18-1/4")
Bowl sizes:
381mm (15") wide 254mm (10") front to back 165mm (6-1/2") deep
Compliance Certifications - Meets or Exceeds the Following Specifications:
• ASME A112.19.2 for Vitreous China Fixtures
SEE REVERSE FOR ROUGHING-IN DIMENSIONS
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDE-
LINES AND ANSI A117.1 ACCESSIBLE AND USABLE
BUILDINGS AND FACILITIES - CHECK LOCAL CODES.
Top of front rim mounted 864mm (34") from finished floor.
0356.028
0356.041
BARRIER FREE
M20 © 2008 AS America Inc.
102 mm (4)
152 mm (6)
152 mm (6)
86 mm (3-3/8)
203 mm (8)
8 mm (5/16)
464 mm (18-1/4)
521 mm (20-1/2)
13 mm (1/2)
FINISHED
WALL
(6) 25mm (1") DIA.
ACCESS HOLES
FOR CONC. ARMS
102 mm (4)
25 mm (1)
79 mm (3-1/8)
267 mm (10-1/2)
425 mm (16-3/4)
114 mm (4-1/2)
44 mm (1-3/4)
38 mm (1-1/2)
10mm (3/8)
DIA. ANCHOR
SCREW HOLES
203 mm
(8)
SUPPLIES
AS REQUIRED
1-1/4 O.D. WASTE
OUTLET FOR
DRAIN PLUG
1-1/4 O.D. WASTE
OUTLET FOR
POP-UP DRAIN
27mm X 14mm (1-1/16 x 5/16) SLOTS
S-9 HANGER
206 mm (8-1/8)
*286 mm (11-1/4)
298 mm (11-3/8)*
352 mm (13-7/8)*
787mm (31) 864mm (34)
FINISHED
FLOOR
54mm (2-1/8) DIA.
HOLES FOR
CONCEALED ARMS
203 mm (8)
0356.015 8" CTRS FOR WALL HANGER OR
CONCEALED ARMS
0356.037 8" CTRS FOR WALL HANGER OR
CONCEALED ARMS EXTRA RIGHT HAND HOLE
NOTES:
* DIMENSIONS SHOWN FOR LOCATION OF SUPPLIES AND “P” TRAP
ARE SUGGESTED.
PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS.
FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.
CONCEALED ARM SUPPORT AS REQUIRED TO BE FURNISHED BY
OTHERS.
IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.2. These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided pages.
LAVATORY DESIGNED TO MEET ADA HANDICAPPED
| GUIDELINES WITH MOUNTING HEIGHT SET AT 864MM (34") |
| ABOVE FINISHED FLOOR. |
LUCERNE™
WALL-HUNG LAVATORY
VITREOUS CHINA
0356.073 8" CTRS FOR WALL HANGER OR
CONCEALED ARMS EXTRA LEFT HAND HOLE
102 mm (4)
152 mm (6)
152 mm (6)
86 mm (3-3/8)
54mm (2-1/8) 203 mm
(8)
8 mm (5/16)
464 mm (18-1/4)
521 mm (20-1/2)
13 mm (1/2)
FINISHED
WALL
(6) 25mm (1") DIA.
ACCESS HOLES
FOR CONC. ARMS
102 mm (4)
25 mm (1)
79 mm (3-1/8)
267 mm (10-1/2)
425 mm (16-3/4)
114 mm (4-1/2)
44 mm (1-3/4)
38 mm (1-1/2)
10mm (3/8)
DIA. ANCHOR
SCREW HOLES
203 mm
(8)
SUPPLIES
AS REQUIRED
1-1/4 O.D. WASTE
OUTLET FOR
DRAIN PLUG
1-1/4 O.D. WASTE
OUTLET FOR
POP-UP DRAIN
27mm X 14mm (1-1/16 x 5/16) SLOTS
S-9 HANGER
206 mm (8-1/8)
*286 mm (11-1/4)
298 mm (11-3/8)*
352 mm (13-7/8)*
787mm (31) 864mm (34)
FINISHED
FLOOR
54mm (2-1/8) DIA.
HOLES FOR
CONCEALED ARMS
203 mm (8)
165 mm (6-1/2)
102 mm (4)
152 mm (6)
152 mm (6)
86 mm (3-3/8)
54mm (2-1/8)
203 mm (8)
8 mm (5/16)
464 mm (18-1/4)
521 mm (20-1/2)
13 mm (1/2)
FINISHED
WALL
(6) 25mm (1") DIA.
ACCESS HOLES
FOR CONC. ARMS
102 mm (4)
25 mm (1)
79 mm (3-1/8)
267 mm (10-1/2)
425 mm (16-3/4)
114 mm (4-1/2)
44 mm (1-3/4)
38 mm (1-1/2)
10mm (3/8)
DIA. ANCHOR
SCREW HOLES
203 mm
(8)
SUPPLIES
AS REQUIRED
1-1/4 O.D. WASTE
OUTLET FOR
DRAIN PLUG
1-1/4 O.D. WASTE
OUTLET FOR
POP-UP DRAIN
27mm X 14mm (1-1/16 x 5/16) SLOTS
S-9 HANGER
206 mm (8-1/8)
*286 mm (11-1/4)
298 mm (11-3/8)*
352 mm (13-7/8)*
787mm (31) 864mm (34)
FINISHED
FLOOR
54mm (2-1/8) DIA.
HOLES FOR
CONCEALED ARMS
203 mm (8)
165 mm (6-1/2)
Revised 8/05
M21 © 2008 AS America Inc. Revised 8/05
102 mm (4)
152 mm (6)
152 mm (6)
102 mm (4)
86 mm (3-3/8)
203 mm (8)
8 mm (5/16)
464 mm (18-1/4)
521 mm (20-1/2)
13 mm (1/2)
FINISHED
WALL
(6) 25mm (1") DIA.
ACCESS HOLES
FOR CONC. ARMS
102 mm (4)
25 mm (1)
79 mm (3-1/8)
267 mm (10-1/2)
425 mm (16-3/4)
114 mm (4-1/2)
44 mm (1-3/4)
38 mm (1-1/2)
10mm (3/8)
DIA. ANCHOR
SCREW HOLES
203 mm
(8)
SUPPLIES
AS REQUIRED
1-1/4 O.D. WASTE
OUTLET FOR
DRAIN PLUG
1-1/4 O.D. WASTE
OUTLET FOR
POP-UP DRAIN
27mm X 14mm (1-1/16 x 5/16) SLOTS
S-9 HANGER
206 mm (8-1/8)
*260 mm (10-1/4)
298 mm (11-3/8)*
352 mm (13-7/8)*
787mm (31) 864mm (34)
FINISHED
FLOOR
54mm (2-1/8) DIA.
HOLES FOR
CONCEALED ARMS
0355.012 4" CTRS FOR WALL HANGER OR
CONCEALED ARMS
0355.034 4" CTRS FOR WALL HANGER OR
CONCEALED ARMS EXTRA RIGHT HAND HOLE
NOTES:
* DIMENSIONS SHOWN FOR LOCATION OF SUPPLIES AND “P” TRAP
ARE SUGGESTED.
PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS.
FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.
CONCEALED ARM SUPPORT AS REQUIRED TO BE FURNISHED BY
OTHERS.
IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.2. These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided pages.
LAVATORY DESIGNED TO MEET ADA HANDICAPPED
| GUIDELINES WITH MOUNTING HEIGHT SET AT 864MM (34") |
| ABOVE FINISHED FLOOR. |
LUCERNE™
WALL-HUNG LAVATORY
VITREOUS CHINA
0355.056 4" CTRS FOR WALL HANGER OR
CONCEALED ARMS EXTRA LEFT HAND HOLE
102 mm (4)
152 mm (6)
152 mm (6)
102 mm (4)
86 mm (3-3/8)
203 mm (8)
8 mm (5/16)
464 mm (18-1/4)
521 mm (20-1/2)
13 mm (1/2)
FINISHED
WALL
(6) 25mm (1") DIA.
ACCESS HOLES
FOR CONC. ARMS
102 mm (4)
25 mm (1)
79 mm (3-1/8)
267 mm (10-1/2)
425 mm (16-3/4)
114 mm (4-1/2)
44 mm (1-3/4)
38 mm (1-1/2)
10mm (3/8)
DIA. ANCHOR
SCREW HOLES
203 mm
(8)
SUPPLIES
AS REQUIRED
1-1/4 O.D. WASTE
OUTLET FOR
DRAIN PLUG
1-1/4 O.D. WASTE
OUTLET FOR
POP-UP DRAIN
27mm X 14mm (1-1/16 x 5/16) SLOTS
S-9 HANGER
206 mm (8-1/8)
*260 mm (10-1/4)
298 mm (11-3/8)*
352 mm (13-7/8)*
787mm (31) 864mm (34)
FINISHED
FLOOR
54mm (2-1/8) DIA.
HOLES FOR
CONCEALED ARMS
54 mm (2-1/8)
165 mm (6-1/2)
102 mm (4)
152 mm (6)
152 mm (6)
102 mm (4)
86 mm (3-3/8)
54 mm (2-1/8) 203 mm
(8)
8 mm (5/16)
464 mm (18-1/4)
521 mm (20-1/2)
13 mm (1/2)
FINISHED
WALL
(6) 25mm (1") DIA.
ACCESS HOLES
FOR CONC. ARMS
102 mm (4)
25 mm (1)
79 mm (3-1/8)
267 mm (10-1/2)
425 mm (16-3/4)
114 mm (4-1/2)
44 mm (1-3/4)
38 mm (1-1/2)
10mm (3/8)
DIA. ANCHOR
SCREW HOLES
203 mm
(8)
SUPPLIES
AS REQUIRED
1-1/4 O.D. WASTE
OUTLET FOR
DRAIN PLUG
1-1/4 O.D. WASTE
OUTLET FOR
POP-UP DRAIN
27mm X 14mm (1-1/16 x 5/16) SLOTS
S-9 HANGER
206 mm (8-1/8)
*260 mm (10-1/4)
298 mm (11-3/8)*
352 mm (13-7/8)*
787mm (31) 864mm (34)
FINISHED
FLOOR
54mm (2-1/8) DIA.
HOLES FOR
CONCEALED ARMS
165 mm (6-1/2)
M22 © 2008 AS America Inc. Revised 9/04
102 mm (4)
152 mm (6)
152 mm (6)
86 mm (3-3/8)
203 mm (8)
8 mm (5/16)
464 mm (18-1/4)
FINISHED
WALL
(6) 25mm (1") DIA.
ACCESS HOLES
FOR CONC. ARMS
102 mm (4)
79 mm (3-1/8)
425 mm (16-3/4)
44 mm (1-3/4)
38 mm (1-1/2)
10mm (3/8)
DIA. ANCHOR
SCREW HOLES
206 mm (8-1/8)
787mm (31) 864mm (34)
FINISHED
FLOOR
54mm (2-1/8) DIA.
HOLES FOR
CONCEALED ARMS
25 mm (1)
267 mm (10-1/2)
114 mm (4-1/2)
27mm X 14mm (1-1/16 x 5/16) SLOTS
S-9 HANGER
25mm (1-3/8) DIA.
PUNCHING
521 mm (20-1/2)
13 mm (1/2)
44mm (1-3/4) DIA.
STD. OUTLET
0356.421 SINGLE CENTER HOLE FOR WALL HANGER
OR CONCEALED ARMS
0356.137 SINGLE CENTER HOLE FOR WALL HANGER OR
CONCEALED ARMS WITH EXTRA RIGHT HAND HOLE
NOTES:
* DIMENSIONS SHOWN FOR LOCATION OF SUPPLIES AND “P” TRAP
ARE SUGGESTED.
PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS.
FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.
CONCEALED ARM SUPPORT AS REQUIRED TO BE FURNISHED BY
OTHERS.
IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.2. These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided pages.
LAVATORY DESIGNED TO MEET ADA HANDICAPPED
| GUIDELINES WITH MOUNTING HEIGHT SET AT 864MM (34") |
| ABOVE FINISHED FLOOR. |
LUCERNE™
WALL-HUNG LAVATORY
VITREOUS CHINA
102 mm (4)
152 mm (6)
152 mm (6)
86 mm (3-3/8)
54 mm (2-1/8) 203 mm
(8)
8 mm (5/16)
464 mm (18-1/4)
FINISHED
WALL
(6) 25mm (1") DIA.
ACCESS HOLES
FOR CONC. ARMS
102 mm (4)
79 mm (3-1/8)
425 mm (16-3/4)
44 mm (1-3/4)
38 mm (1-1/2)
10mm (3/8)
DIA. ANCHOR
SCREW HOLES
206 mm (8-1/8)
787mm (31) 864mm (34)
FINISHED
FLOOR
54mm (2-1/8) DIA.
HOLES FOR
CONCEALED ARMS
25 mm (1)
267 mm (10-1/2)
165 mm (6-1/2)
114 mm (4-1/2)
27mm X 14mm (1-1/16 x 5/16) SLOTS
S-9 HANGER
25mm (1-3/8) DIA.
PUNCHING
521 mm (20-1/2)
13 mm (1/2)
44mm (1-3/4) DIA.
STD. OUTLET
102 mm (4)
152 mm (6)
152 mm (6)
86 mm (3-3/8)
54 mm (2-1/8) 203 mm
(8)
8 mm (5/16)
464 mm (18-1/4)
FINISHED
WALL
(6) 25mm (1") DIA.
ACCESS HOLES
FOR CONC. ARMS
102 mm (4)
79 mm (3-1/8)
425 mm (16-3/4)
44 mm (1-3/4)
38 mm (1-1/2)
10mm (3/8)
DIA. ANCHOR
SCREW HOLES
206 mm (8-1/8)
787mm (31) 864mm (34)
FINISHED
FLOOR
54mm (2-1/8) DIA.
HOLES FOR
CONCEALED ARMS
25 mm (1)
267 mm (10-1/2)
165 mm (6-1/2)
114 mm (4-1/2)
27mm X 14mm (1-1/16 x 5/16) SLOTS
S-9 HANGER
25mm (1-3/8) DIA.
PUNCHING
521 mm (20-1/2)
13 mm (1/2)
44mm (1-3/4) DIA.
STD. OUTLET
0356.115 SINGLE CENTER HOLE FOR WALL HANGER OR
CONCEALED ARMS WITH EXTRA LEFT HAND HOLE
Job Name ________________________________________________
Item Number _____________________________________________
Section/Tag ______________________________________________
Model Specified ___________________________________________
Architect _________________________________________________
Engineer _________________________________________________
Contractor ________________________________________________
[ ] Submitted as Shown [ ] Submitted with Variations
Date _____________________________________________________
MECHANICAL FAUCETS
895-317GN2FCAB
Manual and Metering Faucets
Product Type___________________________________________________ Deck Mounted 4" Fixed Centers Hot and Cold Water Sink Faucet
Features & Specifications___________________________________________________
• 4" Fixed Centers
• 5-1/4" Flow Control Rigid / Swing Gooseneck Spout
• 4" Wristblade Handle
• Quaturn Compression Operating Cartridge
• 1/2" NPSM Supply Inlets and Coupling Nut for 3/8" or 1/2" Flexible Riser
• 1.5 GPM (5.7 L/min) Laminar Flow Control Insert in Spout Inlet
• ECAST® design provides durable brass construction with total lead content equal to or less than 0.25% by weighted average
• CFNow! Item Ships in 5 Days
Performance Specification___________________________________________________
• Rated Operating Pressure: 20-125 PSI
• Rated Operating Temperature: 40-140ºF
Warranty___________________________________________________
• Lifetime Limited Faucet Warranty
• 5-Year Limited Cartridge Warranty
• 1-Year Limited Finish Warranty
Codes & Standards___________________________________________________
• ASME A112.18.1/CSA B125.1
• Certified to NSF/ANSI 61, Section 9 by CSA
• ADA ANSI/ICC A117.1
ECAST products are intended for installation where state laws and local codes mandate lead content levels or in any location where lead content is a concern.
Last Revision: 03/22/2013 • Date Printed: 05/30/2013 • Product specifications subject to change without notice
2100 South Clearwater Drive Des Plaines, IL
P: 847/803-5000 F: 847/803-5454
Technical: 800/TEC-TRUE www.chicagofaucets.com
895-317GN2FCAB
Manual and Metering Faucets
Architect/Engineer Specification________________________________________________________________________________________________________ Chicago Faucets No. 895-317GN2FCAB, Deck Mounted 4" Fixed Centers Hot and Cold Water Sink Faucet, Chrome Plated solid brass construction. 5-1/4" Center to Center Flow Control Rigid / Swing Gooseneck Spout. 1.5 GPM (5.7 L/min) Laminar Flow Control Insert in Spout
Inlet. 4" Metal Wristblade handle(s) with Sixteen Point Tapered Broach and Secured Blue and Red Buttons. Quaturn™ rebuildable compression cartridge, opens and closes 90°, closes with water pressure, features square tapered stem. 1/2" NPSM Supply Inlets and Coupling Nut for 3/8" or
1/2" Flexible Riser. Mounting hardware includedECAST® construction with less than 0.25% lead content by weighted average. This product meets ADA ANSI/ICC A117.1 requirements and is tested and certified to industry standards: ASME A112.18.1/CSA B125.1, and Certified to
NSF/ANSI 61, Section 9 by CSA.
Operation and Maintenance________________________________________________________________________________________________________ Installation should be in accordance with local plumbing codes. Flush all pipes thoroughly before installation. After installation, remove spout outlet or flow control and flush faucet thoroughly to clear any debris. Care should be taken when cleaning the product. Do not use abrasive cleaners, chemicals or solvents as they can result in surface damage. Use mild soap and warm water for cleaning and protecting the life of Chicago Faucet products. For specific operation and maintenance refer to the installation instructions and repair parts documents that are located at www.chicagofaucets.com.
Chicago Faucets, member of the Geberit Group, is the leading brand of commercial faucets and fittings in the United States, offering a complete range of products for schools, laboratories, hospitals, office buildings, food service, airports and sport facilities.
Call 1.800.TECTRUE or 1.847.803.5000 Option 1 for installation or other technical assistance.
Last Revision: 03/22/2013 • Date Printed: 05/30/2013 • Product specifications subject to change without notice
2100 South Clearwater Drive Des Plaines, IL
P: 847/803-5000 F: 847/803-5454
Technical: 800/TEC-TRUE www.chicagofaucets.com
File details come from the government source that posted it. Updated .