20260930 589A7-23-306 REVISIONS RENOVATE 5 and 5B FOR MENTAL HEALTH.pdf
PDF 349 KB Posted
- Solicitation number
- 36C25526R0171
About this file
This document is a set of architectural contract drawings for the renovation of Buildings 5 and 5B at the Wichita, Kansas VA Medical Center, issued by the U.S. Department of Veterans Affairs, Office of Construction and Facilities Management. The project number is 589A7-23-306, with an issue date of September 30, 2026.
The drawings depict the demolition and renovation plans for a mental health facility renovation on the first floor, totaling 969 square feet. Key demolition work includes removal of interior partitions down to structure, ceiling systems and suspended equipment, floor finishes, doors and frames, window glazing, cabinetwork, shelving, toilet partitions, and plumbing fixtures. The renovation introduces multiple exam offices (166A-D), a police room (163), copy work room (165), group therapy space (167), and supporting facilities including reception, waiting areas, hallways, elevators, and mechanical/electrical rooms. New construction incorporates fire-rated and smoke-rated partitions per the SOC (Smoke and Fire Compartmentalization) Plan Legend, with 1-hour to 4-hour fire barriers and smoke barriers strategically positioned throughout. Door schedules specify hollow metal frames with 15-minute fire ratings for secure areas and include security screens for designated windows. The design team includes Alesia Architecture P.C., BDH Engineering, and Farris Engineering. The facility is noted as fully sprinklered, and the contractor is required to field verify all existing conditions and coordinate phasing with the VA owner.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25526R0171 0002.pdf | ||
| Pre-bid Questions Renovate Bldg. 5 and 5B for Mental Health.docx | DOCX document | |
| Pre-Bid Conference Sign-in Sheet 589A7-23-306.pdf | ||
| Group Therapy Room Pic 2.jpg | JPG image | |
| 36C25526R0171 0001.pdf | ||
| Group Therapy Room Pic 1.jpg | JPG image | |
| S02 589A7-23-306 Drawings.pdf | ||
| S02 Attachment- PPQ 589A7-23-306 Renovate Bldg. 5 5B for Mental Health.docx | DOCX document | |
| 36C25526R0171.docx | DOCX document | |
| S02 MP Cutsheets 589A7-23-306.pdf | ||
| P09 589A7-23-306 Specifications CD Documents.pdf | ||
| S02 Lighting Cutsheets 589A7-23-306.pdf | ||
| S02 Finish Schedule 589A7-23-306.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
504 SF
GROUP
THERAPY
167-5
130 SF
OFFICE
174-5
130 SF
OFFICE
175-5
122 SF
COPY WORK
ROOM
165-5
121 SF
RECEPTION
162-5
91 SF
ELEV.
EQUIP.
154-5
65 SF
ELEVATOR
153-5
65 SF
ELEVATOR
152-5
503 SF
WAITING
151-5
54 SF
INTERVIEW
155-5
135 SF
VESTIBULE
150-5
267 SF
STAIR
156-5
42 SF
COMM.
158-5
39 SF
VESTIBULE
159-5
19 SF
JAN
160-5
502 SF
HALLWAY
157-5
174 SF
WOMEN'S
161-5
174 SF
MEN'S
168-5
39 SF
VESTIBULE
169-5
62 SF
ELECTRICAL
170-5
78 SF
FIRE
SPRINKLER
MECH. RM.
171-5
127 SF
OFFICE
172-5
127 SF
OFFICE
173-5
269 SF
HALLWAY
176-5
131 SF
OFFICE
178-5
131 SF
OFFICE
179-5
269 SF
STAIR
171-5
Redundant Room
STORAGE
164-5
A
B
C
A
A
A
A
D
D
D
4' -0
5'-8"
C
A
DEMOLITION PLAN LEGEND:
FULL HEIGHT ONE-HOUR FIRE RATED TEMPORARY PARTITION
ELEMENT TO BE REMOVED, TYP.
INDICATES AREA TO BE REMOVED, TYP
EXISITING CONSTRUCTION TO REMAIN UNO.
RICHARD
JOSEPH
ONKEN
A-5125
A
R C H I T E
C
T
S T
A T
E
O F N E B
R A
S K
A
09/30/2026
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
Alesia Architecture P.C.
3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941
BDH Engineering 440 Regency Parkway, Suit 135 Omaha, Nebraska 68114 Phone: (402) 981-5527
Farris Engineering 12700 W Dodge Rd, Omaha, NE 68154 Phone: (402) 330-5900
A on e ei gh th in ch o ne f oo t th re e in ch es o ne f oo t
6" on e an d on e ha lf in ch es o ne f oo t on e in ch o ne f oo t
6" 6" th re e qu ar te rs in ch o ne f oo t on e ha lf in ch o ne f oo t th re e ei gh th s in ch o ne f oo t on e qu ar te r in ch o ne f oo t
CONTRACT DOCUMENTS RENOVATE 5 & 5B FOR
MENTAL HEALTH
589A7-23-306
5b
WICHITA, KS
A
B
C
D
E
F
30 SEPTEMBER 2026 RJO IJM
A u to d e s k D o c s /1
A -2
-3
R e n o v a te B ld g b f o r
M e n ta l H e a lt h
/5
A
-2
-3
.A rc h
R
-R e n o v a te B ld g b f o r M e n ta l H e a lt h
.r v t
/3
/2
:1
:3
P
M
AD101
DEMOLITION PLANS
DEMOLITION KEYNOTE LEGEND
KEY KEYNOTE
A REMOVE GWB AND METAL STUD WALL SYSTEM
B REMOVE FOLDING ROOM DIVIDER AND RELATED MECHANISM
C REMOVE CABINETWORK, SHELVING, BASES.
D FULL HEIGHT ONE-HOUR FIRE RATED TEMPORARY PARTITION
GENERAL DEMOLITION NOTES
1 DASHED BOLD LINES INDICATE EXTENT OF DEMOLITION INCLUDING THE FOLLOWING:
* INTERIOR PARTITIONS (REMOVED TO STRUCTURE)
* CEILINGS, INCLUDING CEILING SUSPENSION SYSTEM, MISC. STEEL SUPPORTS FOR SUSPENDED
EQUIPMENT, SUSPENDED EQUIPMENT, LIGHT FIXTURES, DIFFUSERS AND GRILLES ETC.
* FLOOR FINISHES (TO CONCRETE) INCLUDING CARPET, RVT, SHEET VINYL, CERAMIC TILE, QUARRY
TILE, BRICK PAVERS, ETC.
* DOORS AND FRAMES UNLESS NOTED OTHERWISE IN DOOR SCHEDULE
* WINDOW GLAZING AND FRAMES UNLESS NOTED OTHERWISE
* BRICK AND BACK-UP WALL SYSTEM
* CABINETWORK, SHELVING, BASES
* TOILET PARTITIONS AND ACCESSORIES
* TACK BOARDS, MARKER BOARDS, PEGBOARDS, DISPLAY BOARDS
* EQUIPMENT ITEMS
* PLUMBING FIXTURES
2 CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS.
3 ALL LIGHT OR HALFTONE LINES INDICATE EXISTING TO REMAIN.
4 SEE SPECIFICATIONS SECTIONS FOR CUTTING AND PATCHING AND DEMOLITION 02 41 00.
5 SEE ROOM FINISH SCHEDULE, MECHANICAL PLANS, AND ELECTRICAL PLANS FOR EXTENT OF NEW
CEILING CONSTRUCTION OR CEILING PATCHING IN EXISTING AREAS.
6 SEE ROOM FINISH SCHEDULE FOR EXTENT OF NEW FLOORING MATERIAL IN EXISTING AREAS.
7 SEE ROOM FINISH SCHEDULE FOR EXTENT OF NEW WALL COVERING MATERIAL IN EXISTING AREAS.
WHERE NEW FINISHES ARE REQUIRED REMOVE EXISTING WALL FINISHES, (TEXRURED PLASTIC COATING, VINYL WALL COVERING, PANELING, BASE, ETC.).
8 CONTRACTOR TO VERIFY ALL WALL CONSTRUCTION & FINISHES NOTED FOR REMOVAL. TAKE INTO
ACCOUNT ANY DISCREPANCY AND MAKE PROPER ADJUSTMENT TO ACCOMPLISH REQUIRED
CONSTRUCTION & FINISHES. IF STRUCTURAL INTEGRITY IS VIOLATED, CONTACT ARCHITECT.
COORDINATE PHASING WITH OWNER
9 COORDINATE REMOVAL OF FURNITURE AND EXISTING EQUIPMENT WITH OWNER.
10 SAW CUT EDGES OF EXISTING FLOOR SLAB FOR REMOVAL AND INSTALLATION OF UTILITIES. REFER TO
MECHANICAL AND ELECTRICAL DRAWINGS.
11 REMOVE FURRING OR GWB ONLY WHERE REQUIRED TO COMPLETE CONSTRUCTION. PATCH AND MATCH WALLS AS REQUIRED TO COMPLETE AND MATCH EXISTING CONDITIONS, UNLESS AN ALTERNATIVE
MATERIAL AND FINISH IS INDICATED.
12 REMOVE CEILINGS ONLY AS REQUIRED FOR NEW CONSTRUCTION. REINSTALL, REPLACE OR PATCH AS
REQUIRED.
1/4" = 1'-0"1
FIRST FLOOR - DEMOLITION PLAN
Mark Revisions: Date:
1 Revision 1 Date 1 imurphree Rectangle imurphree Text Box 09/30/2026
UP
SSSSSS
S S
S S
S S
S S
S S
S S
SSSS
S S
S S
S S
SS
S S
S S
S S
ELEVATOR
152-5
ELEVATOR
153-5
ELEV.
EQUIP.
154-5
RECEPTION
162-5
WOMEN'S
161-5
MEN'S
168-5
COMM.
158-5
JAN
160-5
STAIR
156-5
WAITING
151-5
INTERVIEW
155-5
HALLWAY
157-5
VESTIBULE
169-5
ELECTRICAL
170-5
FIRE
SPRINKLER
MECH. RM.
171-5OFFICE
172-5
OFFICE
173-5
OFFICE
174-5
OFFICE
175-5
504 SF
GROUP
THERAPY
167-5
HALLWAY
176-5
OFFICE
178-5
OFFICE
179-5
STAIR
171-5
VESTIBULE
159-5
110 SF
POLICE
163-5
VESTIBULE
150-5
120 SF
EXAM
OFFICE
166D-5
120 SF
EXAM
OFFICE
166C-5
125 SF
EXAM
OFFICE
166B-5
125 SF
EXAM
OFFICE
166A-5
122 SF
COPY WORK
ROOM
165-5
10'-0"
'-6
'-6
9'-7"
155 SF
HALLWAY
157B-5
6'-0"
Q Q
Q
Q
Q
Q
Q
Q
Q Q
GH166C
GH166D
GH166B
GH166A
GH163
GH165
13'-2"
8' -4
'-8
8'-10"
6'-8"
AE101
2AE101
G G
H
GH167
E
E
125 SF
EXAM
OFFICE
166A-5
125 SF
EXAM
OFFICE
166B-5
F
F
120 SF
EXAM
OFFICE
166C-5
120 SF
EXAM
OFFICE
166D-5
SMOKE PARTITION
SYMBOL
SOC PLAN LEGEND
DESCRIPTION
1-HOUR FIRE BARRIER
2-HOUR FIRE BARRIER
3-HOUR FIRE BARRIER
SMOKE BARRIER
1-HOUR SMOKE BARRIER
2-HOUR SMOKE BARRIER
3-HOUR SMOKE BARRIER
4-HOUR FIRE BARRIER
4-HOUR SMOKE BARRIER
30-MINUTE SMOKE BARRIER
30-MINUTE FIRE BARRIER
S S
S
S
S
S
S
S
S
S
S S
RICHARD
JOSEPH
ONKEN
A-5125
A
R C H I T E
C
T
S T
A T
E
O F N E B
R A
S K
A
09/30/2026
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
Alesia Architecture P.C.
3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941
BDH Engineering 440 Regency Parkway, Suit 135 Omaha, Nebraska 68114 Phone: (402) 981-5527
Farris Engineering 12700 W Dodge Rd, Omaha, NE 68154 Phone: (402) 330-5900
A on e ei gh th in ch o ne f oo t th re e in ch es o ne f oo t
6" on e an d on e ha lf in ch es o ne f oo t on e in ch o ne f oo t
6" 6" th re e qu ar te rs in ch o ne f oo t on e ha lf in ch o ne f oo t th re e ei gh th s in ch o ne f oo t on e qu ar te r in ch o ne f oo t
CONTRACT DOCUMENTS RENOVATE 5 & 5B FOR
MENTAL HEALTH
589A7-23-306
5b
WICHITA, KS
A
B
C
D
E
F
30 SEPTEMBER 2026 RJO IJM
A u to d e s k D o c s /1
A -2
-3
R e n o v a te B ld g b f o r
M e n ta l H e a lt h
/5
A
-2
-3
.A rc h
R
-R e n o v a te B ld g b f o r M e n ta l H e a lt h
.r v t
/3
/2
:1
:4
P
M
AE101
FIRST FLOOR PLAN
GENERAL NOTES
1 ALL NEW CONSTRUCTION IS INDICATED BOLD OR FULL TONE.
2 ALL INTERIOR WALLS WILL BE TYPE "A" CONSTRUCTION UNLESS OTHERWISE INDICATED. REFER TO
SHEET A-801.
3 ALL METAL STUD AND GYPSUM WALLBOARD PARTITIONS ARE DIMENSIONED TO THE OUTSIDE FACE AND
TO COLUMN GRID UNLESS OTHERWISE NOTED.
4 WHEN WALL PARTITIONS OF DIFFERENT FIRE RATING INTERSECT, THE HIGHEST RATED PARTITION TAKES
PRECEDENT. MAINTAIN RATING BEHIND FIRE EXTINGUISHER CABINETS, ETC.
5 CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO CONSTRUCTION.
6 REFER TO THE Q SERIES FOR ARCHITECTURAL CABINETWORK AND EQUIPMENT NUMBERS.
7 REFER TO SHEET AE802 FOR TYPICAL BACKING DETAIL WITHIN INTERIOR WALL PARTITION, HANDRAILS, CUBICAL CURTAIN TRACKS, CORNER GUARDS ETC.
8 ALL EXISTING TO REMAIN CEILING AND WALL GRILLES, DIFFUSERS AND LIGHTS ETC. TO BE CLEANED.
9 VERIFY THAT THE EXISTING WALLS REQUIRING FIRE RATING ARE MAINTAINED, REPAIRED AND EXTENDED
TO STRUCTURE.
10 ALL CORRIDOR WALLS ARE REQUIRED TO BE SMOKE TIGHT, WHETHER THEY ARE FIRE RATED OR NOT.
REPAIR AND EXTEND AT LEAST THE CORRIDOR SIDE OF NON-FIRE RATED CORRIDOR WALLS TO
STRUCTURE, UNLESS NOTED OTHERWISE NOTED. SEE PARTITION TYPES SHEET.
11 REFER TO LIFE SAFETY PLANS FOR LOCATION OF REQUIRED FIRE WALLS.
12 ALL FURNITURE SHOWN HALF TONE WILL BE OWNER FURNISHED AND OWNER INSTALLED.
PROJECT AREA
FIRST FLOOR: 969 SF
SECOND FLOOR: 000 SF
TOTAL: 969 SF
1/4" = 1'-0"1
FIRST FLOOR - FLOOR PLAN
1/4" = 1'-0"2
FIRST FLOOR - DEDUCT ALTERNATE 1
1/4" = 1'-0"3
FIRST FLOOR - DEDUCT ALTERNATE 2
KEYNOTE LEGEND
KEY KEYNOTE
E SINKS IN EXAM OFFICE 166A AND 166B REMOVED FROM SCOPE.
F SINKS IN EXAM OFFICE 166C AND 166D REMOVED FROM SCOPE.
G SECURITY SCREEN TO BE ADDED TO WINDOWS OF SECURE ROOM.
H WALL REPAIR TO BE PERFORMED WHERE NECESSARY.
Mark Revisions: Date:
1 Revision 1 Date 1 imurphree Rectangle imurphree
F
FLUSH
@ RATED
DOORS
@ NON-RATED
DOORS
* 4"
8"
N
FLUSH
HOLLOW METAL
2"
SCHEDULE
SEE DOOR 2"
HOSPITAL
STOPS @
INTERIOR
DOORS
ONLY
4" S
E E
D O
O R
S C
H E
D U
LE
HOLLOW METAL FRAME
BOTTOM OF FRAME
4" MATCH EXISTING FRAMES
45°
TYP.
4"
HOLLOW METAL FRAME
WALL - SEE
PLAN FOR TYPE
WALL (WHERE OCCURS)
- SEE PLAN FOR TYPE
V A
R
IE
S
S E
E P
LA
N
1/ 2"
1/ 2"
2"
VARIES
SEE PLAN
1/2"1/2"
4"
WALL - SEE
PLAN FOR TYPE
SEALANT - EA. SIDE
& ALL AROUND, TYP.
HOLLOW METAL
FRAME
ADJACENT WALL
WHERE OCCURS
SEALANT - EA. SIDE
& ALL AROUND, TYP.
HOLLOW
METAL
FRAME
A
HEAD JAMB
B3" = 1'-0" 3" = 1'-0"
WALL - SEE
PLAN FOR TYPE
MOUNTING SCREWS
SECURITY SCREEN
EXISTING EXTERIOR WALL
EXISTING WINDOW FRAME
RICHARD
JOSEPH
ONKEN
A-5125
A
R C H I T E
C
T
S T
A T
E
O F N E B
R A
S K
A
09/30/2026
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
Alesia Architecture P.C.
3705 North 200th Street Elkhorn, Nebraska 68022 Phone: (402) 291-6941
BDH Engineering 440 Regency Parkway, Suit 135 Omaha, Nebraska 68114 Phone: (402) 981-5527
Farris Engineering 12700 W Dodge Rd, Omaha, NE 68154 Phone: (402) 330-5900
A on e ei gh th in ch o ne f oo t th re e in ch es o ne f oo t
6" on e an d on e ha lf in ch es o ne f oo t on e in ch o ne f oo t
6" 6" th re e qu ar te rs in ch o ne f oo t on e ha lf in ch o ne f oo t th re e ei gh th s in ch o ne f oo t on e qu ar te r in ch o ne f oo t
CONTRACT DOCUMENTS RENOVATE 5 & 5B FOR
MENTAL HEALTH
589A7-23-306
5b
WICHITA, KS
A
B
C
D
E
F
30 SEPTEMBER 2026 RJO IJM
A u to d e s k D o c s /1
A -2
-3
R e n o v a te B ld g b f o r
M e n ta l H e a lt h
/5
A
-2
-3
.A rc h
R
-R e n o v a te B ld g b f o r M e n ta l H e a lt h
.r v t
/3
/2
:1
:4
P
M
AE701
DOOR AND FRAME TYPES, DETAILS
AND DOOR SCHEDULE
DOOR SCHEDULE
DOOR NUMBER ROOM NAME DOOR SIZE HARDWARE DOOR MATERIAL DOOR TYPE DOOR FINISH FRAME TYPE
FRAME
MATERIAL FRAME FINISH FIRE RATING REMARKS
GH163 POLICE 3'-6" x 7'-0" HW-SH-3 HM F P-3 1 HM P-3 FE 15 MIN LEVEL 3
GH165 COPY WORK ROOM 3'-4" x 7'-0" HW-4N WD N S-1 1 HM P-3 GLASS TYPE MG-1
GH166A EXAM OFFICE 4'-0" x 7'-0" HW-4N WD N S-1 1 HM P-3 GLASS TYPE LG-1
GH166B EXAM OFFICE 4'-0" x 7'-0" HW-4N WD N S-1 1 HM P-3 GLASS TYPE LG-1
GH166C EXAM OFFICE 4'-0" x 7'-0" HW-4N WD N S-1 1 HM P-3 GLASS TYPE LG-1
GH166D EXAM OFFICE 4'-0" x 7'-0" HW-4N WD N S-1 1 HM P-3 GLASS TYPE LG-1
GH167 RECEPTION 3'-4" x 7'-0" HW-4N WD N S-1 1 HM P-3 GLASS TYPE LG-1
1/4" = 1'-0"1
HOLLOW METAL OR WOOD DOOR TYPES
1/4" = 1'-0"2
FRAME TYPES
1 1/2" = 1'-0"4
HOSPITAL STOPS
1 1/2" = 1'-0"5
DOOR FRAME OFFSET
GLASS TYPE SCHEDULE NOTES:
A: COMPLY WITH UL LEVEL 3 PROTECTION LEVEL, SPSA - SUPER POWER SMALL ARMS
REMARKS:
1. SEE SPECIFICATIONS FOR DOOR HARDWARE
2. SEE SHEETS AE701 FOR DOOR RAME DETAILS
GLASS TYPE SCHEDULE
REF TYPE Description Thickness Remarks
1 MG-1 CLEAR, TEMPERED TONGLESS FLOAT 6mm --
2 LG-1 LAMINATED GLASS 9.5mm
3" = 1'-0"3
DOOR DETAILS A
6" = 1'-0"6
SECURITY SCREEN DETAIL
Mark Revisions: Date:
1 Revision 1 Date 1 imurphree Rectangle imurphree
| Sheets |
| AD101 - DEMOLITION PLANS |
| AE101 - FIRST FLOOR PLAN |
| AE701 - DOOR AND FRAME TYPES, DETAILS AND DOOR SCHEDULE |
File details come from the government source that posted it. Updated .