S02 - Exhibit_3 537-24-105 SOC Floor Plan.pdf
PDF 1 MB Posted
- Attached to
- Z2DA--537-24-105 OR Suite Lighting Replacement Federal contract opportunity
- Solicitation number
- 36C25225B0018
About this file
This document is a Statement of Conditions (SOC) floor plan for the Jesse Brown VA Medical Center in Chicago, IL, specifically detailing fire safety and occupancy requirements for Building 40. The document comprehensively lists applicable national fire codes and standards, including NFPA 101 Life Safety Code (2024 edition), and mandates specific information to be included on architectural drawings such as fire barriers, smoke barriers, hazardous areas, exits, and suite identifications.
The occupancy table provides a detailed breakdown of floor spaces across multiple buildings, with Building 40 designated as a fully sprinklered, mixed-response type Health Care Occupancy. The partial second floor plan for Building 40 shows various medical spaces including operating rooms, holding bays, nurse stations, corridors, and support areas. The drawing includes a comprehensive device list indicating fire safety equipment locations such as fire extinguishers, exit signs, emergency lights, fire alarm pull stations, and sprinkler system risers, with specific notations about existing infrastructure and equivalency considerations for certain building elements.
View the file
Other files for this federal contract opportunity
Show all 23
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OCCUPANCY TABLEAPPLICABLE CODES AND STANDARDS:
1. THE JOINT COMMISSION HAS ADOPTED THE NATIONAL FIRE CODES PUBLISHED BY THE NATIONAL FIRE PROTECTION ASSOCIATION. LIFE SAFETY REQUIREMENTS ARE SPECIFICALLY ADDRESSED IN THE 2024
EDITION OF NFPA 101, LIFE SAFETY CODE.
2. THE 1960 PUBLIC BUILDING AMENDMENT ACT (PL100-678) REQUIRES ALL FEDERAL AGENCIES TO FOLLOW THE LATEST EDITIONS OF NATIONALLY RECOGNIZED FIRE AND LIFE SAFETY CODES. ALL NEW CONSTRUCTION OR BUILDING RENOVATIONS ARE REQUIRED TO COMPLY WITH THE LATEST EDITION OF NFPA 101 OR IT'S REFERENCED STANDARDS. EXISTING BUILDING CONDITIONS ARE REQUIRED TO COMPLY WITH THE APPLICABLE CODES OR STANDARDS AT THE TIME OF BUILDING DESIGN AND THE APPLICABLE PROVISIONS FOR EXISTING BUILDINGS IN CURRENT EDITIONS OF APPLICABLE CODES AND
STANDARDS.
3. OTHER NFPA CODES AND STANDARDS:
A. NFPA 10 - PORTABLE FIRE EXTINGUISHERS, 2022 EDITION
B. NFPA 13 - SPRINKLER SYSTEMS, 2022 EDITION
C. NFPA 14 - STANDPIPE SYSTEMS, 2024 EDITION
D. NFPA 20 - FIRE PUMPS, 2022 EDITION
E. NFPA 25 - WATER-BASED FIRE PROTECTION SYSTEMS 2023 EDITION
F. NFPA 70 - NATIONAL ELECTRIC CODE, 2023 EDITION
G. NFPA 72 - NATIONAL FIRE ALARM CODE, 2022 EDITION
H. NFPA 75 - ELECTRONIC COMPUTER EQUIPMENT, 2020 EDITION
I. NFPA 80 - FIRE DOORS, 2022 EDITION
J. NFPA 90A&B - HEATING AND AIR CONDITIONING SYSTEMS, 2024 EDITION
K. NFPA 96 - COMMERCIAL COOKING EQUIPMENT, 2024 EDITION
L. NFPA 99 - HEALTH CARE FACILITIES CODE, 2024 EDITION
M. NFPA 105 - SMOKE DOORS, 2022 EDITION
N. NFPA 110 - EMERGENCY POWER SYSTEMS, 2022 EDITION
O. NFPA 241 - CONSTRUCTION AND DEMOLITION, 2022 EDITION
INFORMATION REQUIRED ON SOC DRAWINGS:
1. IDENTIFY IF THE BUILDING IS SPRINKLER PROTECTED THROUGHOUT OR IDENTIFY THOSE AREAS OF THE
BUILDING WITH SPRINKLER PROTECTION (FIRE EXTINGUISHER LOCATIONS NOT REQUIRED)
2. LEGEND SHOWING FEATURES OF FIRE SAFETY
3. FIRE BARRIERS
3.1. IF VERTICAL ENCLOSURES ARE IDENTIFIES WITH FIRE BARRIERS, THEY ARE NOT ALSO REQUIRED
TO BE LABELED AS TO THEIR FUNCTION (I.E., LINEN CHUTE/HVAC SHAFT/ELEVATOR, ETC.)
4. SMOKE BARRIERS
5. HAZARDOUS AREAS (AS DEFINED BY NFPA 101, 19.3.2.1.5 AND 21.3.2.1)
6. EXITS (EXIT SIGN LOCATIONS NOT REQUIRED TO BE SHOWN)
7. SUITES, INCLUDING THE TYPE (SLEEPING, PATIENT CARE NON-SLEEPING, NON-PATIENT CARE) AND
SUITE SIZE (MAXIMUM SUITE SIZE IS PER CURRENT EDITION OF NFPA 101)
7.1. SUITE IDENTIFICATION IS ONLY PROVIDED FOR HEALTHCARE OCCUPANCIES
8. EQUIVALENCIES PREVIOUSLY APPROVED BY TJC (ON DRAWINGS WHERE THE COVERED DEFICIENCIES
ARE LOCATED)
8.1. SUMMARY OF DEFICIENCIES COVERED BY APPROVED EQUIVALENCY
8.2. SUMMARY OF COMPENSATING MEASURES FOR DEFICIENCIES
NOTE: THE LIST ABOVE IS MANDATORY; OTHER FEATURES MAY OPTIONALLY BE INCLUDED ON THE DRAWINGS.
EXIT SIGN AND FIRE EXTINGUISHER LOCATIONS ARE NOT REQUIRED TO BE SHOWN ON THE DRAWINGS
Building No. Floor Health Care Ambulatory Health Care Business Industrial Dormitory Total
1 12 0 0 0 2,680 0 2,680
1 11 0 0 0 4,308 0 4,308
1 10 0 0 17,406 0 0 17,406
1 9 0 0 0 0 23,416 23,416
1 8 0 0 28,012 0 0 28,012
1 7 0 0 28,069 0 0 28,069
1 6 0 0 34,211 0 0 34,211
1 5 0 33,921 0 0 0 33,921
1 4 0 33,551 0 0 0 33,551
1 3 0 37,402 0 0 0 37,402
1 2 0 0 47,177 0 0 47,177
1 1 0 61,110 0 0 0 61,110
1 Basement 0 0 0 11,599 0 11,599
SUB TOTALS 0 165,984 154,875 18,587 23,416 362,862
5 1 0 0 2,779 0 0 2,779
SUB TOTALS 0 0 2,779 0 0 2,779
11 & 30 9 0 0 2,488 0 0 2,488
11 & 30 8 0 0 13,494 0 0 13,494
11 & 30 7 0 0 36,997 0 0 36,997
11 & 30 6 0 0 38,988 0 0 38,988
11 & 30 5 0 0 37,073 0 0 37,073
11 & 30 4 0 0 36,937 0 0 36,937
11 & 30 3 0 0 37,023 0 0 37,023
11 & 30 2 0 0 48,325 0 0 48,325
11 & 30 1 0 4,669 86,834 0 0 91,503
11 & 30 Basement 0 0 0 3,995 0 3,995
SUB TOTALS 0 4,669 338,159 3,995 0 346,823
32 2 0 0 7,732 0 0 7,732
32 1 0 0 7,773 0 0 7,773
SUB TOTALS 0 0 15,505 0 0 15,505
40 9 0 0 0 1,414 0 1,414
40 8 0 0 0 10,463 0 10,463
40 7 23,293 0 0 0 0 23,293
40 6 34,611 0 0 0 0 34,611
40 5 33,018 0 0 0 0 33,018
40 4 34,246 0 0 0 0 34,246
40 3 0 0 0 24,024 0 24,024
40 2 31,532 0 0 0 0 31,532
40 1 0 36,640 0 0 0 36,640
40 Basement 0 0 0 29,956 0 29,956
SUB TOTALS 156,700 36,640 0 65,857 0 259,197
GRAND TOTALS 156,700 207,293 493,034 88,439 23,416 968,882
DATEREVISIONS: NUMBER
FP&C Project Number Project NumberProject Title
Location
Issue Date Checked by Drawn by
Drawing NumberApproved: Project Director
Drawing Title
ENGINEERS
Building Number
SITE NAME/ADDRESS
CONSULTANTS KC, LLC.
1330 BURLINGTON STREET, SUITE 200
NORTH KANSAS CITY, MO 64116
(816) 931-3377
FP&C
JLB/BWC DJB/KLB 38Dwg. of
23400.00
CHICAGO, IL
UPDATE STATEMENT OF
CONDITIONS
JESSE BROWN VAMCJesse Brown VA Medical Center
820 South Damen Ave Chicago, IL 60612
VAPAHCS PLANNING AND ENGINEERING DEV-X1
ALL
4/2/2024
537-24-104
33% SUBMITTAL 4/2/2024
66% SUBMITTAL
95% SUBMITTAL
FINAL SUBMITTAL
6/6/2024 7/9/2024 8/9/2024
BUILDING ALL
DEVICE DRAWINGS
COVER PAGE
ST
OR
AG
E
B
AN
ES
T
RE
SI
DE
NT
OF
FI
CE
-3
CO
RR
ID
OR
C2
CO
NN
EC
TI
NG
CO
RR
ID
OR
C2
CO
RR
ID
OR
C2
CO
RR
ID
OR
C2
CO
RR
ID
OR
C2
CO
RR
ID
OR
C2
CO
RR
ID
OR
C2
EL
EV
AT
OR
P2
EL
EV
AT
OR
P2
EL
EV
AT
OR
P2
EL
EC
TR
IC
AL
RM 26
E1
AN
ES
T W
OR
K
SA
TE
LL
IT
E
PH
AR
MA
CY
HO
LD
IN
G
BA
Y
CO
RR
ID
OR
C2
EL
EC
TR
IC
AL
RM 26
E3
HO
LD
IN
G
BA
Y
HO
LD
IN
G
BA
Y
HO
LD
IN
G
BA
Y
EL
EV
AT
OR
P2
EL
EV
AT
OR
P2
ST
AI
R
ST
-1
HA
C
H4
TO
ILE
T
B
LO
CK
ER
TO
ILE
T
A
AN
ES
T
SV
C
SE
CY
OF
FI
CE
OF
FI
CE
-1
AN
ES
TH
ES
IO
LO
GY
AT
TE
ND
IN
G
OF
FI
CE
-2
AN
ES
TH
ES
IO
LO
GY
AT
TE
ND
IN
G
OF
FI
CE
-4
AN
ES
T
TE
CH
S
OF
FI
CE
ST
OR
AG
E
75AN
ES
TH
ES
IO
LO
GY
AT
TE
ND
IN
G
OF
FI
CE
-5
CR
NA
OF
FI
CE
-6
AN
ES
T
AD
MI
N
OF
FI
CE
R
SU
RG
IC
AL
SV
C
OF
FI
CE
-8
SU
RG
IC
AL
SV
C
OF
FI
CE
-9
ST
AI
R
NO
OF
FI
CE
TO
ILE
T
NU
RS
E
ST
AT
IO
N
NU
RS
E
ST
AT
IO
N
NU
RS
E
ST
AT
IO
N
NU
RS
E
ST
AT
IO
N
NU
RS
E
ST
AT
IO
N
HO
LD
IN
G
BA
Y
HO
LD
IN
G
BA
Y
HO
LD
IN
G
BA
Y
HO
LD
IN
G
BA
Y
CL
EA
N
SU
PP
Y
HO
LD
IN
G
RM 26
HO
LD
IN
G
RM 26
HO
LD
IN
G
RM 26
HO
LD
IN
G
RM 26
IS
OL
AT
IO
N
HO
LD
IN
G
RM 26
SO
ILE
D
UT
ILI
TY
TO
ILE
T
HA
C
H3
DI
CT
AT
IO
N
D
ST
AF
F
LO
UN
GE
TO
ILE
T
A
TO
ILE
T
B
TO
ILE
T
C
CY
ST
OS
CO
PY
R
M
CY
ST
O
CL
EA
N
UP
R
M
A
CY
ST
O
ST
OR
AG
E
B
OR
-7
OR
-6
EL
EV
AT
OR
NO
ST
ER
ILE
C
OR
E
AN
NE
X
ST
AI
R
NO
OR
-5
EL
EC
TR
IC
AL
RM 26
E2
ST
ER
ILE
CO
RE
EL
EV
AT
OR
NO
RE
CY
CL
IN
G
CO
NT
RO
L
ST
AT
IO
N
SO
ILE
D
UT
ILI
TY
ST
OR
AG
E
EM
S
H2
AL
CO
VE
CO
MM
R M
T1
A
CO
MM
R
M
T1
LIN
EN
CH
UT
E
L1
OF
FI
CE
ST
OR
AG
E
EQ
UI
P
ST
OR
AG
E
EQ
UI
P
ST
OR
AG
E
CL
EA
N
LIN
EN
HA
C
H1
VE
ST
IB
UL
E
OR
S
UP
PO
RT
OR
-3
(L
AR
GE
OR
-4
(L
AR
GE
OR
-2
(L
AR
GE
OR
-1
(L
AR
GE
OR
S
UP
PO
RT
VE
ST
IB
UL
E
ST
AI
R
ST
-1
4 EL
EV
AT
OR
S2
EL
EV
AT
OR
S2
EL
EV
AT
OR
S2
OR
S
UP
PO
RT
ST
ME
NS
TO
ILE
T
LO 2
OF
FI
CE
ST
ER
ILE
MA
CH
ST
ER
ILE
MA
CH
GL
AS
S
CA
NO
PY
LO
BB
Y
EL
EV
AT
OR
PN
EU
MA
TI
C
TU
BE
CA
NO
PY
VE
ST
IB
UL
E
CO
NC
RE
TE
RE
CE
IV
IN
G
CA
RT
EL
EV
AT
OR
(M
AI
N
LO
BB
Y)
OP
EN
T O
BE
LO
W
GL
AS
S
CA
NO
PY
OP
EN
T O
BE
LO
W
LO
BB
Y
SH
EL
F
PA
RK
IN
G
EQ
UI
PM
EN
T
EQ
UI
PM
EN
TPA
RK
IN
G
PA
RK
IN
G
EQ
UI
PM
EN
T
ST
RE
TC
HPA
RK
IN
G
ST
RE
TC
H
PA
RK
IN
G
ST
RE
TC
H
PA
RK
IN
G
ST
RE
TC
H
ST
RE
TC
HPA
RK
IN
G
PA
RK
IN
G
PA
RK
IN
G
ST
RE
TC
H
PA
RK
IN
G
EQ
UI
PM
EN
T
PA
RK
IN
G
EQ
UI
PM
EN
T
PA
RK
IN
G
EQ
UI
PM
EN
T
EQ
UI
PM
EN
T
PA
RK
IN
G
EQ
UI
PM
EN
T
PA
RK
IN
G
PA
RK
IN
GEQ
UI
PM
EN
T
PA
RK
IN
GST
RE
TC
H
ST
RE
TC
H
EQ
UI
PM
EN
T
PA
RK
IN
G
PA
RK
IN
G
EQ
UI
PM
EN
T
PA
RK
IN
G
PA
RK
IN
G
EQ
UI
PM
EN
T
EQUIPMENT PARKING
EQUIPMENT PARKING
EQUIPMENT PARKING
2 W
EST
2 CENTER
2 EAST
F
F F
F F
F
EW
F
EW
EW
OPEN TO BELOW
PA
RK
IN
G
EQ
UI
PM
EN
T
PA
RK
IN
G
EQ
UI
PM
EN
T
EQ
UI
PM
EN
T
PA
RK
IN
G
LC
PARTIAL SECOND FLOOR PLAN
BUILDING 40
FULLY SPRINKLERED; MIXED RESPONSE TYPE
HEALTH CARE OCCUPANCY
BUILDING 1
BUSINESS
OCCUPANCY
BUILDING 40
HEALTH CARE
OCCUPANCY
SUITE DESCRIPTIONS
SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE
SMOKE ZONE SQ. FT. OCCUPANCY
SMOKE ZONE SIZE
NUMBER OF MEANS OF EGRESS
Staff Stair - Not used as an exit. No exit signs required.
DATEREVISIONS: NUMBER
FP&C Project Number Project NumberProject Title
Location
Issue Date Checked by Drawn by
Drawing NumberApproved: Project Director
Drawing Title
ENGINEERS
Building Number
SITE NAME/ADDRESS
CONSULTANTS KC, LLC.
1330 BURLINGTON STREET, SUITE 200
NORTH KANSAS CITY, MO 64116
(816) 931-3377
FP&C
JLB/BWC DJB/KLB 38Dwg. of
23400.00
CHICAGO, IL
UPDATE STATEMENT OF
CONDITIONS
JESSE BROWN VAMCJesse Brown VA Medical Center
820 South Damen Ave Chicago, IL 60612
VAPAHCS PLANNING AND ENGINEERING
EW
FAAP
FACP
DEVICE LIST
FIRE EXTINGUISHER
EXIT SIGN
EMERGENCY LIGHT
FIRE ALARM PULL STATION
FIRE ALARM CONTROL PANEL
FIRE ALARM ANNUNCIATOR PANEL
AUTOMATED EXTERNAL DEFIBRILLATOR
F
AED
EYEWASH STATION
SPRINKLER SYSTEM RISER
POSITIVE PRESSURE ROOM 15%
NEGATIVE PRESSURE ROOM 15%
POSITIVE PRESSURE ROOM 30%
NEGATIVE PRESSURE ROOM 30%
PARTIAL SECOND FLOOR PLAN
BUILDING 40
DEVICE DRAWINGS
40DEV-2
4/2/2024
537-24-104
SITE PLAN
OGDEN AVENUE
PO
LK
S
TR
EE
T
DAMEN AVENUE
TA
YL
O R
S
TR
EE
T
33% SUBMITTAL 4/2/2024
2-HOUR FIRE BARRIER
SMOKE ZONE BARRIER
1-HOUR FIRE BARRIER
SMOKE RESISTIVE PARTITION
SUITE DESIGNATION
HAZARDOUS ROOM ENCLOSURE
LEGEND
HORIZONTAL EXIT
EXIT DISCHARGE
OCCUPANCY/SMOKE ZONE BOUNDARY
EXIT STAIR/PASSAGEWAY
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
EP
LC
TC
EX
HE
66% SUBMITTAL
95% SUBMITTAL
FINAL SUBMITTAL
6/6/2024 7/9/2024 8/9/2024
EXIT PASSAGEWAY PER SECTION 7.2.6
OF NFPA 101-2024 EDITION. UTILITIES
INSTALLED ABOVE SUSPENDED
CEILING PRIOR TO THE CURRENT
REQUIREMENTS NOW FOUND IN
SECTION 7.1.3.2.1(9) OF NFPA 101-2024
EDITION AND FIRST ADOPTED IN THE
1985 EDITION.
ELECTRICAL UTILITY INSTALLED IN
STAIR ENCLOSURE PRIOR TO THE
CURRENT REQUIREMENTS NOW
FOUND IN SECTION 7.1.3.2.1(9) OF
NFPA 101-2024 EDITION AND FIRST
ADOPTED IN THE 1985 EDITION.
FIRE SPRINKLERS INSTALLED PER
LIBRARY AND SHELVING STORAGE
SPACING REQUIREMENTS OF SECTION
9.3.7 OF NFPA 13-2022 EDITION.
FOAM ACOUSTICAL PANELS
INSTALLED ON THE CEILINGS HAVE A
CLASS A SMOKE SPREAD AND SMOKE
DENSITY RATING ( SEE TECHNICAL
DATA SHEET IN SOC BINDER) PER THE
ASTM E84 FIRE MATERIALS TEST AND
AS PERMITTED BY SECTION 18/19.3.3.2
OF NFPA 101-2024 EDITION.
NON SPRINKLERED PIPE SPACE PER
SECTION 9.2.1.2 OF NFPA 13-2022
EDITION
EXISTING 3/16" MINIMUM STEEL PLATE
FLOOR ACCESS PANEL CONSIDERED
EQUIVALENT TO 2 HOUR FLOOR
ASSEMBLY AT THE TIME OF BUILDING
CONSTRUCTION.
B
C
J
M
N
P
KEY NOTES:
SEE EQUIVALENCY FOR DEAD END
CORRIDORS WITHIN A BUSINESS
OCCUPANCY.
EQUIVALENCY:
AutoCAD SHX Text
CO2
AutoCAD SHX Text
CO2
AutoCAD SHX Text
CO2
AutoCAD SHX Text
CO2
AutoCAD SHX Text
CO2
AutoCAD SHX Text
CO2
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
OR SUITE
AutoCAD SHX Text 12,230 Sq. Ft.
AutoCAD SHX Text
AutoCAD SHX Text
NON SLEEPING
AutoCAD SHX Text
PATIENT CARE
AutoCAD SHX Text 9,366 Sq. Ft.
AutoCAD SHX Text
WEST
AutoCAD SHX Text 6,526 Sq. Ft.
AutoCAD SHX Text
CENTER
AutoCAD SHX Text 15,519 Sq. Ft.
AutoCAD SHX Text
EAST
AutoCAD SHX Text
HEALTH CARE
AutoCAD SHX Text
HEALTH CARE
AutoCAD SHX Text
HEALTH CARE
AutoCAD SHX Text
PACU
AutoCAD SHX Text 4,560 Sq. Ft.
AutoCAD SHX Text
AutoCAD SHX Text
NON SLEEPING
AutoCAD SHX Text
PATIENT CARE
| JESSE BROWN DEV 2 |
| JESSE BROWN DEV 28 |
File details come from the government source that posted it. Updated .