This is a Pre-Renovation NESHAP Asbestos Survey and Mercury Vapor Sampling Report for the Louis Stokes Cleveland Veteran Affairs Medical Center located at 10701 East Boulevard, Cleveland, Ohio 44106.
CT Consultants, Inc., a Verdantas company, conducted a comprehensive environmental assessment of the sub-basement and limited sewer access manholes at the facility during four inspection dates between December 16, 2024, and February 19, 2025. Four Ohio Environmental Protection Agency-licensed Asbestos Hazard Evaluation Specialists performed the survey. The assessment included visual observations, bulk sampling of suspect asbestos-containing materials (ACMs) and soil samples, mercury vapor sampling, polarized light microscopy (PLM) analysis using EPA 600/R93/116 methodology, and California Air Resources Board (CARB) 435 analysis. Laboratory analysis of 27 soil samples and 3 fireproofing samples was conducted by Eurofins CEI, Inc., which is accredited by the National Voluntary Laboratory Accreditation Program. The findings indicate no asbestos was detected in any analyzed samples when using the CARB 435 method, although the PLM method initially detected chrysotile in two soil samples (H-30 and L-18), which upon further testing with the more rigorous CARB 435 method showed no asbestos present. Mercury vapor sampling of 29 composite soil locations and 3 sewer manhole air samples revealed all readings were below OSHA's permissible exposure limit of 0.1 mg/m³, ACGIH's threshold limit value of 0.025 mg/m³, and NIOSH's recommended exposure limit of 0.05 mg/m³. The universal waste inventory identified 93 blast-proof lighting enclosures and bulbs requiring removal. The report recommends any additional unidentified materials discovered during renovation be treated as assumed ACM until proven otherwise through laboratory analysis, and the Cleveland Sewer District should continue mercury sampling in accordance with an established schedule.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| S02. 01 00 00 - GENERAL REQUIREMENTS - Update.pdf | ||
| S02. 541-24-103_Cleveland Sub-Basement_Final Bid Drawings.pdf | ||
| S02. 541-24-103_Cleveland Sub-Basement_Final Bid Specs.pdf | ||
| S02. Bid Opening Instructions.docx | DOCX document | |
| S02. Wage Determination OH20260074.pdf | ||
| S02. Safety.docx | DOCX document | |
| S02. Site Visit Information.docx | DOCX document | |
| S02. 36C25026B0035_1 - Solicitation.pdf | ||
| S02. Calculation of Self-Performed and Sub-Contracted Work.docx | DOCX document | |
| S02. Improve Sub-Basement Plumbing and Air Quality - SOW.pdf | ||
| S02. RFI Form.docx | DOCX document |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
8150 Sterling Court Mentor, Ohio 44060
440-951-9000
July 3, 2025
Christopher Thomas, PE, PMP Sr. Mechanical Engineer/Project Manager Above Group, Inc 305 East Drive, Suite H Melbourne, FL 32904 cthomas@abovegroupinc.com
Re: Pre-Renovation NESHAP Asbestos Survey and Mercury Vapor Sampling for the Louis Stokes Cleveland Veteran Affairs Medical Center located at 10701 East Boulevard, Cleveland, Ohio 44106.
Dear Mr. Thomas, CT Consultants, Inc. (CT), a Verdantas company, is pleased to provide this report which summarizes the findings of the Pre-Renovation National Emission Standards for Hazardous Air Pollutants (NESHAP) Asbestos Survey, d Mercury Vapor Sampling, and Universal Waste inventory conducted at selected locations at the above-mentioned site.
Background CT conducted a NESHAP asbestos survey, throughout the sub-basement and limited sewer access manholes in the Louis Stokes Cleveland Veteran Affairs Medical Center (LSCVAMC) at 10701 East Boulevard, Cleveland, Ohio 44106. The purpose of this project was to utilize an Ohio Environmental Protection Agency (OEPA) licensed Asbestos Hazard Evaluation Specialist (AHES) to locate and identify asbestos-containing materials (ACM) and possible Mercury Vapor Hazards within the sub-basement and limited sewer access manholes at the address listed above prior to renovation activities. Site-specific information is presented in the following table:
Dates of Inspection: 12/16 (’24), 01/06 (25), 01/19 (“25), 02/19 (25) Site Address: 10701 East Blvd, Cleveland, OH 44106
Site Owner Representative: VAMC- Eric Browning
Inspector(s):
Steve Regovich: AHES #ES32475, Brendan Niehaus: AHES #ES547146, Robert Serlin: AHES #ES36371, Jonathan Adams: AHES #ES549770
Facility Construction Date: Original Construction1963 Number of Buildings: Multi
Building Description: Multi-Story Veterans Medical Hospital mailto:cthomas@abovegroupinc.com
Above Group, Inc.
July 3, 2025
Verdantas.com
Scope of Services CT’s scope of services for this project consisted of the following tasks:
• Visual observations
• Bulk sampling of suspect ACMs and soil sampling
• Testing of collected samples for Mercury Vapors
• Polarized Light Microscopy (PLM) and California Air Board (CARB) 435 analysis of bulk and soil sample
• Mercury Vapor Sampling
• Universal Waste Inventory
• Preparation of final report
Findings of the Asbestos Survey are summarized below.
Asbestos Survey Methodology
CT team conducted the NESHAP asbestos survey at the LSCVAMC in December 2024, January, and February 2025. Mr. Steve Regovich, Mr. Rob Serlin, Mr. Brendan Niehaus, and Mr. Jonathon Adams conducted the NESHAP asbestos survey. Mr. Regovich, Mr. Serlin, Mr. Neihaus and Mr.
Admas are accredited by State of Ohio as AHES. The survey consisted of a visual inspection and bulk sampling within the sub-basement in accordance with methods outlined in the U.S.
Environmental Protection Agency (EPA) guidance document “Guidance for Controlling Asbestos- Containing Materials in Buildings" (Document No. 560/5-85/024)”. The U.S. EPA defined an ACM as a material that contains greater than one percent (>1%) asbestos by visual estimation of weight. The inspection and sampling included destructive techniques.
All suspect ACM identified during the visual observations were adequately sampled per the federal rules codified in Title 40 of Code of Federal Register (CFR) Part 763.86 and samples were submitted to an accredited lab for analysis by PLM Method EPA 600/R93/116 and EPA 600/M4- 82-020, Modified California Air Resources Board Method (CARB) 435. Sample locations were determined where applicable, according to the random sampling grid included in the EPA document "Asbestos in Buildings Simplified Sampling Scheme for Friable Surfacing Materials", dated October 1985.
Bulk suspect samples were collected in 6 mil zip-lock bags, The collected samples were placed into labeled bag for identification and logged into the sample chain-of-custody.
After the collection of samples was completed, the samples were sealed into another plastic bag and shipped to Eurofins CEI, Inc. (Eurofins) at Fort Mill, North Carolina. Eurofins is accredited by the National Voluntary Laboratory Accreditation Program (NVLP), which is administered by the National Institute of Standards and Technology (NIST).
The certifications are included in Attachment A. A Sample Location Map is included in Attachment B. The analytical laboratory report is included in Attachment C.
https://www.verdantas.com/
Verdantas.com
Universal Waste Inventory
The purpose of the universal waste inventory was to visually identify and quantify existing universal waste materials that need to be removed before demolition or renovation activities.
Universal waste materials include, but are not limited to, mercury-containing devices such as thermostats, fluorescent lighting fixtures and bulbs, potentially polychlorinated biphenyl (PCB)-containing lighting ballasts, high-intensity discharge (HID) lighting fixtures, batteries, pesticides, and aerosol cans.
CT’s scope of work did not include the collection and/or analysis of suspect Universal Waste materials. The Universal Waste Inventory Table can be found in Attachment D CT Consultants, Inc. visually identified the following Universal Waste material at the site:
• Blast Proof Lighting Enclosures and Bulbs – 93
Findings of Asbestos Survey A total of twenty-seven (27) samples were collected from the suspect ACMs, and twenty-seven
(27) layers were collected and analyzed. The soil samples were initially analyzed using the PLM method, followed by analysis with the CARB 435 Method. Material containing asbestos at concentrations equal to or greater than 1% is classified as asbestos-containing material from a regulatory perspective. If the asbestos content is less than 1%, the Occupational Safety and Health Administration (OSHA) considers the material a potential exposure hazard, and all relevant OSHA worker protection requirements apply.
Laboratory results show no asbestos was detected in any analyzed samples.
The sample material description and laboratory results are summarized in Table 1 and Table 2.
Table 1 shows the laboratory analysis by PLM Method and Table 2 shows the laboratory analysis by CARB 435 Metod
Verdantas.com
TABLE 1
Asbestos Survey PLM Results
10701 East Blvd.
December, 2024/January, 2025
HA/Sample Material Location/Quantity Friable Condition Analytical Result*
B-30 Brown Soil Column B-30 Yes NA NAD
D-30 Brown Soil Column D-30 Yes NA NAD
D-12 Brown Soil Column D-12 Yes NA NAD
H-12 Brown Soil Column H-12 Yes NA NAD
H-30 Brown Soil Column H-30 Yes NA Chrysotile J-11 Brown Soil Column J-11 Yes NA NAD
J-12 Brown Soil Column J-12 Yes NA NAD
J-29 Brown Soil Column J-29 Yes NA NAD
J-30 Brown Soil Column J-30 Yes NA NAD
J-35 Brown Soil Column J-35 Yes NA NAD
K-08 Brown Soil Column K-08 Yes NA NAD
K-09 Brown Soil Column K-09 Yes NA NAD
K-13 Brown Soil Column K-13 Yes NA NAD
L-12 Brown Soil Column L-12 Yes NA NAD
L-14 Brown Soil Column L-14 Yes NA NAD
L-16 Brown Soil Column L-16 Yes NA NAD L-18 Brown Soil Column L-18 Yes NA Chrysotile
L-23 Brown Soil Column L-23 Yes NA NAD
L-25 Brown Soil Column L-25 Yes NA NAD
L-27 Brown Soil Column L-27 Yes NA NAD
L-30 Brown Soil Column L-30 Yes NA NAD
N-08 Brown Soil Column N-08 Yes NA NAD
N-12 Brown Soil Column N-12 Yes NA NAD
01-1217- (A-C)
Beige Fireproofing Yes Good NAD
NAD – No Asbestos Detected
Verdantas.com
TABLE 2
Asbestos Survey CARB-435 Results
10701 East Blvd.
December, 2024/January, 2025
HA/Sample Material Location/Quantity Friable Condition Analytical Result*
B-30x Brown Soil Column B-30 Yes NA NAD
D-30x Brown Soil Column D-30 Yes NA NAD
D-12x Brown Soil Column D-12 Yes NA NAD
H-12X Brown Soil Column H-12 Yes NA NAD
H-30X Brown Soil Column H-30 Yes NA NAD
J-11X Brown Soil Column J-11 Yes NA NAD
J-12X Brown Soil Column J-12 Yes NA NAD
J-29X Brown Soil Column J-29 Yes NA NAD
J-30X Brown Soil Column J-30 Yes NA NAD
J-35X Brown Soil Column J-35 Yes NA NAD
K-08X Brown Soil Column K-08 Yes NA NAD
K-09X Brown Soil Column K-09 Yes NA NAD
K-13X Brown Soil Column K-13 Yes NA NAD
L-12X Brown Soil Column L-12 Yes NA NAD
L-14X Brown Soil Column L-14 Yes NA NAD
L-16X Brown Soil Column L-16 Yes NA NAD
L-18X Brown Soil Column L-18 Yes NA NAD
L-23X Brown Soil Column L-23 Yes NA NAD
L-25X Brown Soil Column L-25 Yes NA NAD
L-27X Brown Soil Column L-27 Yes NA NAD
L-30X Brown Soil Column L-30 Yes NA NAD
N-08X Brown Soil Column N-08 Yes NA NAD
N-12X Brown Soil Column N-12 Yes NA NAD
N- 33 Brown Soil Column N- 33 Yes NA NAD
N- 34 Brown Soil Column N- 34 Yes NA NAD
Q- 33 Brown Soil Column Q- 33 Yes NA NAD
Q- 34 Brown Soil Column Q- 34 Yes NA NAD
Any additional unidentified materials discovered during renovation, demolition or construction activities should be treated as assumed ACM in accordance with regulations 29 CFR 1926.1101 and 1910.1001 and other applicable state and local regulations until proven otherwise through laboratory analysis.
Mercury Vapor Sampling Methodology
Composite soil samples were collected throughout the sub-basement using column identifiers to create a grid of coverage throughout the sub-basement. Each sample was collected approximately “1-6” below the surface using a battery powered hole auger. Following the excavation, the soil samples were placed into 6 mil zip-lock bags to allow vapors to accumulate.
After an appropriate waiting period for vapor accumulation, a Jerome J505 mercury sampler was used to analyze the samples in the field for mercury vapors.
Findings of Mercury Vapor Samples Under the authority of the Federal Advisory Committee Act (FACA) P. L. 92-463 of 1972, the National Advisory Committee for Acute Exposure Guideline Levels for Hazardous Substances (NAC/AEGL Committee) has been established to identify, review and interpret relevant toxicologic and other scientific data and develop AEGLs for high priority, acutely toxic chemicals. Mercury vapor, Chemical Abstracts Service (CAS) Reg. No. 7439-97-6, is a colorless, odorless gas generated from elemental mercury or inorganic mercury compounds such as mercuric chloride.
Under ambient conditions, mercury is a silver-white, liquid metal. Metallic mercury is non-flammable and only slightly volatile (vapor pressure of 0.002 mm). (Acute Exposure Guideline, 2010).
The American Conference of Governmental Industrial Hygienists (ACGIH) recommends a Threshold Limit Value (TLV) of 0.025 milligrams per cubic meter (mg/m3) for mercury vapor as 8-hourtime-weighted average (TWA). OSHA has set the personal exposure limit (PEL) of 0.1 mg/m3 as 8-hour TWA. National Institute of Occupational Safety and Health (NIOSH) has a recommended exposure limit (REL) of 0.05 mg/m3 as an 10-hour TWA.)
No field samples analyzed with the Jerome J505 mercury sampler exceeded the PEL of
0.1 mg/m3, TLV of 0.025 mg/m3, or REL of 0.05 mg/m3.
TABLE 2
Asbestos Survey CARB-435 Results
10701 East Blvd.
December, 2024/January, 2025
HA/Sample Material Location/Quantity Friable Condition Analytical Result*
NAD – No Asbestos Detected
Materials sampled and analyzed in the field are summarized in Table 3. A sample location map is included in Attachment E.
Verdantas.com
TABLE 3
Mercury Vapor Sampling Results
10701 East Blvd.
December 2024/January-February, 2025
HA/Sample Material Location/Quantity Results (mg/m3)
B-30 Brown Soil Column B-30 0.00029
D-30 Brown Soil Column D-30 0.00046
D-12 Brown Soil Column D-12 0.00037
H-12 Brown Soil Column H-12 0.00134
H-30 Brown Soil Column H-30 0.00078
J-11 Brown Soil Column J-11 0.00058
J-12 Brown Soil Column J-12 0.00053
J-29 Brown Soil Column J-29 0.00062
J-30 Brown Soil Column J-30 0.00027
J-35 Brown Soil Column J-35 0.00039
K-08 Brown Soil Column K-08 0.00048
K-09 Brown Soil Column K-09 0.00032
K-13 Brown Soil Column K-13 0.00057
L-12 Brown Soil Column L-12 0.00006
L-14 Brown Soil Column L-14 0.00214
L-16 Brown Soil Column L-16 0.00156
L-18 Brown Soil Column L-18 0.00059
L-23 Brown Soil Column L-23 0.00027
L-25 Brown Soil Column L-25 0.00025
L-27 Brown Soil Column L-27 0.00025
L-30 Brown Soil Column L-30 0.00036
N-08 Brown Soil Column N-08 0.00063
N-12 Brown Soil Column N-12 0.00056
N- 33 Brown Soil Column N- 33 0.00047
N- 34 Brown Soil Column N- 34 0.00038
Q- 33 Brown Soil Column Q- 33 0.00018
Q- 34 Brown Soil Column Q- 34 0.00046
Verdantas.com
Conclusions and Recommendations Asbestos Containing Materials
In the 10701 East Blvd. structure, two (2) soil samples were found to be asbestos containing by laboratory analysis using PLM but proven to be negative for asbestos using the CARB method.
Any asbestos removal should be performed by a licensed asbestos abatement company and Ohio Environmental Protection Agency-licensed personnel with oversight by a third party OEPA- Certified Evaluation Specialist.
Mercury Vapor Analysis
Although the samples collected and analyzed in the field did not show levels exceeding the threshold, it is important to note that mercury vapors were detected.
The Cleveland Sewer District should persist with sampling events in accordance with the established schedule to ensure that levels do not approach or exceed the permissible exposure limit (PEL).
Limitations and Reliance The findings and conclusions expressed in this report are based only on conditions observed during our survey of the building components. CT makes no representation or assumptions as to past conditions or future occurrences. The findings of this report represent CT’s professional judgment; no other warranty is expressed or implied. This report is prepared to assist the building owner, architect, construction manager, general contractors, and potential asbestos abatement
TABLE 3
Mercury Vapor Sampling Results
10701 East Blvd.
December 2024/January-February, 2025
HA/Sample Material Location/Quantity Results (mg/m3)
MH #1 Air Storage/Receiving Room 0.00052
MH #2 Air Hallway Outside Receiving 0.00117
MH #3 Air Plumbing Closet 0.00029
MH – Manhole
Verdantas.com contractors in locating ACM, and hazardous materials. This report is not intended as a bidding document or as a project specification document. The limitations of the survey may not qualify this report to be adequate for all EPA and/or OSHA applications.
Our professional services have been performed, our findings obtained, and our conclusions and recommendations prepared in accordance with customary principles and practices in the fields of environmental science and engineering. This report does not warrant against future operations or conditions, nor does it warrant against operations or conditions present at a location not investigated.
This report is for the exclusive use of Above Group, In. The scope of services performed in execution of this evaluation may not be appropriate to satisfy the needs of other users and use or re-use of this document or the findings, conclusions, or recommendations is at the risk of said user.
We appreciate the opportunity to be of service to CT Consultants, Inc. for this project and look forward to working with you on future assignments. If you have questions about information in this report or if we can be of further assistance, please contact us at (440)530-2213.
Respectfully, CT CONSULTANTS, INC.
Brendan Niehaus Steve Regovich Staff Scientist Senior Scientist
Attachments Attachment A – Certifications Attachment B – Asbestos Sample Location Map Attachment C – Laboratory Report 24255 Attachment D – Hazardous Materials Inventory Table Attachment E – Mercury Vapor Sample Location Map
Attachment A Certifications hio Ohio Environmental Protection Agency
Mike DeWine, Governor Jon Husted, Lt. Governor Anne M. Vogel, Director
4/7/2025
Stephen Regovich Ill 535 Shallow Creek Circle Northfield, OH 44067
RE: Evaluation Specialist Certification Number: ES32475 Expiration Date: 4/17/2026
Dear Stephen Regovich 111:
This letter and enclosed certification card approves your request to be certified as an asbestos Evaluation Specialist. You must present your card upon request at anx project site while performing duties. Copies of cards are not acceptable as proof of cert1ficat1on.
This certification may be revoked by the Director of the Ohio Environmental Protection Agency (EPA) for violation of any of the requirements of 3745-22 or 3745-20 of the Ohio Administrative Code.
If you have any questions, please contact the Asbestos Program at 614-644-0226 or by email at asbestoslicensing@epa.oh1o.gov .
. Sincerely, ZJuuub)t,, M s� Brandon Schwendeman Manager, Business Oferations Support Section Ohio EPA - Division o Air Pollution Control
State of Ohio Environmental Protection Agency
Asbestos Program
Asbestos Hazard Evaluation Spec alist
Stephen ■ Regovich Ill l Q 535 Shallow Creek Circle
Northfield OH 44067
Certification Number Expiration Date
ES32475 4/17 '26
50 West Town Street• Suite 700 • P.O. Box 1049 • Columbus, OH 43216-1049 epa.ohio.gov • (614) 644-3020 • (614) 644-3184 (fax) tate O hlO
Environmental Protection Agency Asbestos Program
402 West Paradi
Orrville OH 44667
Certification Number Exp1rat1on Date
ES547146 ,, , ... 5
State of Ohio Environmental Protection Agency
Asbestos Program
Asbestos Hazard Evaluation Specialist
Robert
Serlin r l flt
45738 Lakeview Ct, Apt 16104 cy Novi Ml 48377
Certification Number Expiration Date
DOB: 9/19/71
ES36371 10/24/25
2 Verdantas.com
Attachment B Asbestos Sample Location Map
I
Second Floor r-------------
I
I
I
I
I
/ I
02-0619-A 2-0619-B
Cleveland VAMC/Louis Stokes Medical Center ACM Sample Location Map
10701 East Blvd, Cleveland, OH 44106
Verdantas Project #242559
Attachment C Laboratory Report
CLIENT PROJECT:
LAB CODE:
January 06, 2025
Steve Regovich CT Consultants 8150 Sterling Court Mentor, OH 44060
VAMC-Cleveland, OH 624981-1
Dear Steve, Enclosed are asbestos analysis results for PLM Bulk samples received at our laboratory on December 26, 2024.
The samples were analyzed for asbestos using polarizing light microscopy (PLM) per the EPA 600/R-93/116:
Method for the Determination of Asbestos in Bulk Building Materials and EPA 40 CFR Appendix E to Subpart E of Part 763: Interim Method of the Determination of Asbestos in Bulk Insulation Samples.
Sample results containing >1% asbestos are considered asbestos-containing materials (ACMs) per EPA regulatory requirements. The detection limit for the EPA 600 Method is <1% by calibrated visual estimate.
Thank you for your business and we look forward to continuing good relations.
Kind Regards, Tianbao Bai, Ph.D., CIH Laboratory Director
NVLAP 600323-0
2752 Pleasant Road Suite 100A, • Fort Mill, SC 29708 • (803) 526-5146
ASBESTOS ANALYTICAL REPORT
By: Polarized Light Microscopy
Prepared for
CT Consultants
CLIENT PROJECT: VAMC-Cleveland, OH
LAB CODE: 624981-1
TEST METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
REPORT DATE: 01/06/25
Project: VAMC-Cleveland, OH
Method:
Asbestos Report Summary By: Polarized Light Microscopy
624981-1Lab Code:
EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
Client IDClient IDClient IDClient ID Lab IDLab IDLab IDLab ID LayerLayerLayerLayer Sample DescriptionSample DescriptionSample DescriptionSample Description AsbestosAsbestosAsbestosAsbestos
Column D-12 2944347 Brown soil None DetectedNone DetectedNone DetectedNone Detected
Column H-12 2944348 Brown soil None DetectedNone DetectedNone DetectedNone Detected
Column J-11 2944349 Brown soil None DetectedNone DetectedNone DetectedNone Detected
Column J-12 2944350 Brown soil None DetectedNone DetectedNone DetectedNone Detected
Column K-09 2944351 Brown soil None DetectedNone DetectedNone DetectedNone Detected
Column K-08 2944352 Brown soil None DetectedNone DetectedNone DetectedNone Detected
Column K-13 2944353 Brown soil None DetectedNone DetectedNone DetectedNone Detected
Column N-12 2944354 Brown soil None DetectedNone DetectedNone DetectedNone Detected
Column N-08 2944355 Brown soil None DetectedNone DetectedNone DetectedNone Detected
Project: VAMC-Cleveland, OH
Method:
Asbestos Report Summary By: Polarized Light Microscopy
624981-1Lab Code:
EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
2752 Pleasant Road Suite 100A, • Fort Mill, SC 29708 • (803) 526-5146 Page 1 of 1Page 1 of 4
Client IDClient IDClient IDClient ID LabLabLabLab LabLabLabLab NON-ASBESTOS COMPONENTSNON-ASBESTOS COMPONENTSNON-ASBESTOS COMPONENTSNON-ASBESTOS COMPONENTS ASBESTOSASBESTOSASBESTOSASBESTOS Lab IDLab IDLab IDLab ID DescriptionDescriptionDescriptionDescription AttributesAttributesAttributesAttributes FibrousFibrousFibrousFibrous Non-FibrousNon-FibrousNon-FibrousNon-Fibrous
Column D-12Column D-12Column D-12Column D-12 2944347
Soil Homogeneous Brown Non-Fibrous Loose
Cellulose Glass Hair
Silica Binder
None DetectedNone DetectedNone DetectedNone Detected
Column H-12Column H-12Column H-12Column H-12 2944348
Soil Homogeneous Brown Non-Fibrous Loose
Silica Binder
None DetectedNone DetectedNone DetectedNone Detected
Column J-11Column J-11Column J-11Column J-11 2944349
Soil Homogeneous Brown Non-Fibrous Loose
Silica Binder
None DetectedNone DetectedNone DetectedNone Detected
Column J-12Column J-12Column J-12Column J-12 2944350
Soil Homogeneous Brown Non-Fibrous Loose
Silica Binder
None DetectedNone DetectedNone DetectedNone Detected
Column K-09Column K-09Column K-09Column K-09 2944351
Soil Homogeneous Brown Non-Fibrous Loose
Silica Binder
None DetectedNone DetectedNone DetectedNone Detected
Column K-08Column K-08Column K-08Column K-08 2944352
Soil Homogeneous Brown Non-Fibrous Loose
Silica Binder
None DetectedNone DetectedNone DetectedNone Detected
Column K-13Column K-13Column K-13Column K-13 2944353
Soil Homogeneous Brown Non-Fibrous Loose
Silica Binder
None DetectedNone DetectedNone DetectedNone Detected
Client: CT Consultants 8150 Sterling Court Mentor, OH 44060
Project:
Method:
ASBESTOS BULK ANALYSIS
By: Polarized Light Microscopy
624981-1 12/26/24 01/06/25 01/06/25
Lab Code:
Date Received:
Date Analyzed:
Date Reported:
VAMC-Cleveland, OH
ASBESTOS BULK PLM, EPA 600 METHOD
2752 Pleasant Road Suite 100A, • Fort Mill, SC 29708 • (803) 526-5146 Page 2 of 4
Client IDClient IDClient IDClient ID LabLabLabLab LabLabLabLab NON-ASBESTOS COMPONENTSNON-ASBESTOS COMPONENTSNON-ASBESTOS COMPONENTSNON-ASBESTOS COMPONENTS ASBESTOSASBESTOSASBESTOSASBESTOS Lab IDLab IDLab IDLab ID DescriptionDescriptionDescriptionDescription AttributesAttributesAttributesAttributes FibrousFibrousFibrousFibrous Non-FibrousNon-FibrousNon-FibrousNon-Fibrous
Column N-12Column N-12Column N-12Column N-12 2944354
Soil Homogeneous Brown Non-Fibrous Loose
Silica Binder
None DetectedNone DetectedNone DetectedNone Detected
Column N-08Column N-08Column N-08Column N-08 2944355
Soil Homogeneous Brown Non-Fibrous Loose
Silica Binder
None DetectedNone DetectedNone DetectedNone Detected
Client: CT Consultants 8150 Sterling Court Mentor, OH 44060
Project:
Method:
ASBESTOS BULK ANALYSIS
By: Polarized Light Microscopy
624981-1 12/26/24 01/06/25 01/06/25
Lab Code:
Date Received:
Date Analyzed:
Date Reported:
VAMC-Cleveland, OH
2752 Pleasant Road Suite 100A, • Fort Mill, SC 29708 • (803) 526-5146 Page 3 of 4
LEGEND:LEGEND:LEGEND:LEGEND:
METHOD:METHOD:METHOD:METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
REPORTING LIMIT:REPORTING LIMIT:REPORTING LIMIT:REPORTING LIMIT: <1% by visual estimation
REGULATORY LIMIT:REGULATORY LIMIT:REGULATORY LIMIT:REGULATORY LIMIT: 1% by weight
Due to the limitations of the EPA 600 / R93 / 116 method, nonfriable organically bound materials (NOBs) such as vinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request.
Eurofins Built Environment Testing East, LLC makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results. Interpretation of the analytical results is the sole responsibility of the client. This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins Built Environment Testing East, LLC. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.
Information provided by customer includes customer sample ID and sample description.
Olivia Gardner Analyst
DATA QA:
Raegan Brown 1/6/2025
APPROVED BY:
Tianbao Bai, Ph.D., CIH Laboratory Director
2752 Pleasant Road Suite 100A, • Fort Mill, SC 29708 • (803) 526-5146 Page 4 of 4
SUBMITTED BY INVOICE TO
Client Sample ID Number
RES Job #: 624981
CONTACT INFORMATION SERIES
ASBESTOS LABORATORY REQUESTED ANALYSIS VALID MATRIX CODES LAB NOTES
CHEMISTRY LABORATORY
MICROBIOLOGY LABORATORY
**Turnaround times establish a laboratory priority, subject to laboratory volume and are not guaranteed. Additional fees apply for afterhours, weekends and holidays.**
Laboratory Analysis Instructions
(Sample ID's must be unique)
Company: CT Consultants Company: CT Consultants
Address: 8150 Sterling Court Address: 8150 Sterling Court
Mentor, OH 44060 Mentor, OH 44060
Project Number and/or P.O. #: 242559 Project Zip Code:
Project Description/Location: VAMC-Cleveland, OH
Contact: Steve Regovich -1 PLM Standard Phone: (216) 650-9054
Fax:
Cell:
Final Data Deliverable Email Address:
Steve.Regovich@ctconsultants.com
PLM / PCM / TEM DTL RUSH PRIORITY STANDARD Air = A Bulk = B
Dust = D Food = F
Paint = P Soil = S
Dust RUSH PRIORITY STANDARD
*PRIOR NOTICE REQUIRED FOR SAME DAY TAT
Surface = SU Swab = SW
Tape = T Wipe = W
Metals RUSH PRIORITY STANDARD Drinking Water = DW
Waste Water = WW
Organics* SAME DAY RUSH PRIORITY STANDARD **ASTM E1792 approved wipe media only**
Viable Analysis** PRIORITY STANDARD
**TAT DEPENDENT ON SPEED OF MICROBIAL GROWTH
Medical Device Analysis RUSH STANDARD
Mold Analysis RUSH PRIORITY STANDARD
Special Instructions:
ASBESTOS CHEMISTRY MICROBIOLOGY ICO
1 01-12-17-A X S
2 01-12-17-B X S
3 01-12-17-C X S
4 Column D-12 X S
5 Column H-12 X S
6 Column J-11 X S
7 Column J-12 X S
8 Column K-09 X S
9 Column K-08 X S
10 Column K-13 X S
11 Column N-12 X S
12 Column N-08 X S
P L
M
P L
M S h o rt R ep o rt (E
PA
/6
/R
-9 3/
6)
T E
M
P C
M
D U
S T
M E
TA
L
S
O R
G A
N
IC
S
V
IA
B L
E S
M E
D
IC
A L
M O
L D
S am pl e
V ol um e
(L
A re a
S am pl e
Te m pe ra tu re
C
Le ng th (o r A liq uo ts
) x W id th
(o r A re a/
A liq uo t)
M at rix C od e of
C on ta in er s
D at e C ol le ct ed m m
/d d/ yy
T im e C ol le ct ed hh :m m
Eurofins Built Environment Testing East, LLC establishes a unique Lab Sample ID, for each sample, by preceding each unique Client Sample ID with the laboratory RES Job Number.
Eurofins Built Environment Testing East, LLC will analyze incoming samples based on information received and will not be responsible for errors or omissions in calculations resulting from the inaccuracy of original data. By signing, client/company representative agrees that submission of the following samples for requested analysis as indicated on this Chain of Custody shall consitute an analytical services agreement with payment terms of NET 30 days. Failure to comply with payment terms may result in a 1.5% monthly interest surcharge.
Relinquished By: Date/Time: 12/26/2024 15:45:00 Sample Condition: Acceptable
Received By: Kayla Ramlogan Date/Time: 12/26/2024 15:45:00 Carrier: Fed-Ex
Eurofins Built Environment Testing East, LLC Effective
(919) 481-1413 https://www.eurofinsus.com/builtenv730 SE Maynard Rd, Cary, NC 27511
Client Sample ID Sample Note Quantity Sampler(s)
01-12-17-A Spray-on Fireproofing Sub-Basement N. Beam
01-12-17-B Spray-on Fireproofing Sub-Basement S. Beam
01-12-17-C Spray-on Fireproofing Sub-Basement Decking
Column D-12 12/17/24 1"-6" Composite Soil/Sub Basement
Column H-12 12/17/24 1"-6" Composite Soil/Sub Basement
Column J-11 12/17/24 1"-6" Composite Soil/Sub Basement
Column J-12 12/17/24 1"-6" Composite Soil/Sub Basement
Column K-09 12/17/24 1"-6" Composite Soil/Sub Basement
Column K-08 12/17/24 1"-6" Composite Soil/Sub Basement
Column K-13 12/17/24 1"-6" Composite Soil/Sub Basement
Column N-12 12/17/24 1"-6" Composite Soil/Sub Basement
Column N-08 12/17/24 1"-6" Composite Soil/Sub Basement
CT Consultants Sample Notes
RES #: 624981
Project Number and/or P.O. #: 242559
Project Description/Location: VAMC-Cleveland, OH
�-- eurofins
CEI
27 52 Pleasant Rd. Suite 1 DOA Fort Mill, SC 29 708 Tel· 803-526-5146; Fax: 9 19-481-1442
COMPANY INFORMATION
ECEI CLIENT#:
Company: CT Consultants
Add ress· 8150 Sterling Ct.
Mentor, OH 44060
Billing Email: steve.regovich@ctconsultants.com
Tel: 216-650-9054 ECEI standard terms are Net 30 days
CHAIN OF CUSTODY
ECEI Lob Code:
ECEI Lab I.D. Range:
PROJECT INFORMATION
Job Contact: Steve Regovich
Email/ Tel:
Project Name: VAMC-Cleveland, OH
Project ID#: 242559
P0#:242559
State of sample origin Ohio
IF TAT IS NOT MARKED STANDARD 3 DAY TAT APPLIES.
TURN AROUND TIME
ASBESTOS METHOD 4HR 8 HR 1 DAY 2DAY 3DAY
PLM BULK·SOIL EPA 600/R-93/116 D D D □ □
PLM POINT COUNT (400) EPA 600/R-93/116 □ □ □ □ □
PLM POINT COUNT (1000) EPA 600/R-93/116 □ □ □ □ □
PLM GRAV w POINT COUNT EPA 600/R-93/116 □ □ □ D
PLM BULK CARB 435 □ □ □ □
PCMAIR" NIOSH 7400 D D □ D □
TEMAIR EPA AH ERA D □ □ D □
TEMAIR NIOSH 7402 □ □ □ D □
TEM AIR (PCME) ISO 10312 D □ □ D D
T EMAIR ASTM 6281-15 D □ D D D
CHATFIELD/ EPA 600/R-
D D D D TEM BULK 93/116 Sec 2 5 5 l
T EM SOIL ASTMD7521-16 D D D
TEM VERMICULITE CINCINNATI METHOD D D □
TEM QUALITATIVE IN-HOUSE METHOD D D D
OTH ER: D D D
'Blanks should be taken from the same sample lot as f/old samples, REMARKS/ SPECIAL INSTRUCTIONS:
A ccept Samples
D R eject Samples
Relinquished By: Date/Time Received By: Date/Time
Steve Regovich 12/23/24 / 1O:3OAM LJ 11'( U- 'f l) o '6--, SDAY
EJ
D
D
D
D
D
D
D
By submitting samples, you are agreeing to ECE/'s Terms and Conditions.
Samples will be disposed of 30 days after analysis Page_l__ot L_.
Version. CCOC.01.22 1/2 LM-FM
�� eurofins SAMPLING FORM
CEI
COMPANY CONTACT INFORMATION
Company: CT Consultants Job Contact: Steve Regovich
Project Name: VAMC-Cleveland, OH
Project ID#: 242559 Tei.216.650.9054
VOLUME/
SAMPLE ID# DESCRIPTION/ LOCATION AREA TEST
01-1217-A Spray-on Fireproofing Sub-basement N.Beam PLM EJ TEM c=i
01-1217-B Spray-on Fireproofing Sub-basement S.Beam PLM E:J TEM c:=i
01-1217-C Spray-on Fireproofing Sub-basement Decking PLM E:::J TEM c=i
Column D-12 12/17/24 1"-6" Composite Soil/ Sub BaseMent PLM E:::J TEM c:=i
Column H-12 "
PLM EJ TEM c=i
Column J-11 "
PLM E:J TEM c:=i
Column J-12 "
PLM E:J TEM c=i
Column K-09 " PLM c=i TEM c:=i
Column K-08 " PLM EJ TEM c:=i
Column K-13 " PLM E:J TEM c:J
Column N-12 " PLM CJ TEM c:=i
Column N-08 "
PLM EJ TEM CJ
PLM c=i TEM c:=i
PLM r==J TEM c=i
PLM c=i TEM c=i
PLM c=i TEM C:=J
PLM c=i TEM c=i
PLM r==J TEM c:J
PLM r==J TEM c=i
PLM r==J TEM c=i
PLM r==J TEM c:J
PLM [==:J TEM c:=i
PLM r==J TEM c:J
PLM [==:J TEM c=i
PLM r==J TEM C:=J
PLM [==:J TEM c=i
PLM c=i TEM c:J
PLM [==:J TEM c=i page (_ 'or _2 __
Version CCOC.01 22.2/2 LM-FM
January 06, 2025
Steve Regovich CT Consultants 8150 Sterling Court Mentor, OH 44060
VAMC-Cleveland, OH, 242559 624968-1
Dear Steve, Enclosed are asbestos analysis results for PLM Bulk samples received at our laboratory on December 26, 2024.
The samples were analyzed for asbestos using polarizing light microscopy (PLM) per the EPA 600/R-93/116:
Method for the Determination of Asbestos in Bulk Building Materials and EPA 40 CFR Appendix E to Subpart E of Part 763: Interim Method of the Determination of Asbestos in Bulk Insulation Samples.
Sample results containing >1% asbestos are considered asbestos-containing materials (ACMs) per EPA regulatory requirements. The detection limit for the EPA 600 Method is <1% by calibrated visual estimate.
Thank you for your business and we look forward to continuing good relations.
Kind Regards, Tianbao Bai, Ph.D., CIH Laboratory Director
Prepared for
CT Consultants
CLIENT PROJECT: VAMC-Cleveland, OH, 242559
LAB CODE: 624968-1
TEST METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
Project: VAMC-Cleveland, OH, 242559
Asbestos Report Summary By: Polarized Light Microscopy
624968-1Lab Code:
EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
Client IDClient IDClient IDClient ID Lab IDLab IDLab IDLab ID LayerLayerLayerLayer Sample DescriptionSample DescriptionSample DescriptionSample Description AsbestosAsbestosAsbestosAsbestos
Column L-12 2944245 Brown soil None DetectedNone DetectedNone DetectedNone Detected
Column L-14 2944246 Brown soil None DetectedNone DetectedNone DetectedNone Detected
Column L-16 2944247 Brown soil None DetectedNone DetectedNone DetectedNone Detected
Column L-18 2944248 Brown soil ChrysotileChrysotileChrysotileChrysotile
Column L-23 2944249 Brown soil None DetectedNone DetectedNone DetectedNone Detected
Column L-25 2944250 Brown soil None DetectedNone DetectedNone DetectedNone Detected
Column L-27 2944251 Brown soil None DetectedNone DetectedNone DetectedNone Detected
Column L-30 2944252 Brown soil None DetectedNone DetectedNone DetectedNone Detected
Project: VAMC-Cleveland, OH, 242559
Method:
Asbestos Report Summary By: Polarized Light Microscopy
624968-1Lab Code:
2752 Pleasant Road Suite 100A, • Fort Mill, SC 29708 • (803) 526-5146 Page 1 of 1Page 1 of 4
Client IDClient IDClient IDClient ID LabLabLabLab LabLabLabLab NON-ASBESTOS COMPONENTSNON-ASBESTOS COMPONENTSNON-ASBESTOS COMPONENTSNON-ASBESTOS COMPONENTS ASBESTOSASBESTOSASBESTOSASBESTOS Lab IDLab IDLab IDLab ID DescriptionDescriptionDescriptionDescription AttributesAttributesAttributesAttributes FibrousFibrousFibrousFibrous Non-FibrousNon-FibrousNon-FibrousNon-Fibrous
Column L-12Column L-12Column L-12Column L-12 2944245
Soil Hetrogeneous Brown Non-Fibrous Loosely Bound
Silica Binder
None DetectedNone DetectedNone DetectedNone Detected
Column L-14Column L-14Column L-14Column L-14 2944246
Soil Hetrogeneous Brown Non-Fibrous Loosely Bound
Silica Binder
None DetectedNone DetectedNone DetectedNone Detected
Column L-16Column L-16Column L-16Column L-16 2944247
Soil Hetrogeneous Brown Non-Fibrous Loosely Bound
Silica Binder
None DetectedNone DetectedNone DetectedNone Detected
Column L-18Column L-18Column L-18Column L-18 2944248
Soil Hetrogeneous Brown Non-Fibrous Loosely Bound
Silica Binder
ChrysotileChrysotileChrysotileChrysotile
Column L-23Column L-23Column L-23Column L-23 2944249
Soil Hetrogeneous Brown Non-Fibrous Loosely Bound
Silica Binder
None DetectedNone DetectedNone DetectedNone Detected
Column L-25Column L-25Column L-25Column L-25 2944250
Soil Hetrogeneous Brown Non-Fibrous Loosely Bound
Silica Binder
None DetectedNone DetectedNone DetectedNone Detected
Column L-27Column L-27Column L-27Column L-27 2944251
Soil Hetrogeneous Brown Non-Fibrous Loosely Bound
Silica Binder
None DetectedNone DetectedNone DetectedNone Detected
Client: CT Consultants 8150 Sterling Court Mentor, OH 44060
Project:
Method:
ASBESTOS BULK ANALYSIS
By: Polarized Light Microscopy
624968-1 12/26/24 01/06/25 01/06/25
Lab Code:
Date Received:
Date Analyzed:
Date Reported:
VAMC-Cleveland, OH, 242559
2752 Pleasant Road Suite 100A, • Fort Mill, SC 29708 • (803) 526-5146 Page 2 of 4
Client IDClient IDClient IDClient ID LabLabLabLab LabLabLabLab NON-ASBESTOS COMPONENTSNON-ASBESTOS COMPONENTSNON-ASBESTOS COMPONENTSNON-ASBESTOS COMPONENTS ASBESTOSASBESTOSASBESTOSASBESTOS Lab IDLab IDLab IDLab ID DescriptionDescriptionDescriptionDescription AttributesAttributesAttributesAttributes FibrousFibrousFibrousFibrous Non-FibrousNon-FibrousNon-FibrousNon-Fibrous
Column L-30Column L-30Column L-30Column L-30 2944252
Soil Hetrogeneous Brown Non-Fibrous Loosely Bound
Silica Binder
None DetectedNone DetectedNone DetectedNone Detected
Client: CT Consultants 8150 Sterling Court Mentor, OH 44060
Project:
Method:
ASBESTOS BULK ANALYSIS
By: Polarized Light Microscopy
624968-1 12/26/24 01/06/25 01/06/25
Lab Code:
Date Received:
Date Analyzed:
Date Reported:
VAMC-Cleveland, OH, 242559
2752 Pleasant Road Suite 100A, • Fort Mill, SC 29708 • (803) 526-5146 Page 3 of 4
REPORTING LIMIT:REPORTING LIMIT:REPORTING LIMIT:REPORTING LIMIT: <1% by visual estimation
REGULATORY LIMIT:REGULATORY LIMIT:REGULATORY LIMIT:REGULATORY LIMIT: 1% by weight
Due to the limitations of the EPA 600 / R93 / 116 method, nonfriable organically bound materials (NOBs) such as vinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request.
Eurofins Built Environment Testing East, LLC makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results. Interpretation of the analytical results is the sole responsibility of the client. This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins Built Environment Testing East, LLC. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government.
Information provided by customer includes customer sample ID and sample description.
Raegan Brown Analyst
DATA QA:
Madelyn Schmidt 1/6/2025
APPROVED BY:
Tianbao Bai, Ph.D., CIH
2752 Pleasant Road Suite 100A, • Fort Mill, SC 29708 • (803) 526-5146 Page 4 of 4
RES Job #: 624968
CONTACT INFORMATION SERIES
ASBESTOS LABORATORY REQUESTED ANALYSIS VALID MATRIX CODES LAB NOTES
CHEMISTRY LABORATORY
MICROBIOLOGY LABORATORY
**Turnaround times establish a laboratory priority, subject to laboratory volume and are not guaranteed. Additional fees apply for afterhours, weekends and holidays.**
Laboratory Analysis Instructions
(Sample ID's must be unique)
Company: CT Consultants Company: CT Consultants
Address: 8150 Sterling Court Address: 8150 Sterling Court
Mentor, OH 44060 Mentor, OH 44060
Project Number and/or P.O. #: 242559 Project Zip Code:
Project Description/Location: VAMC-Cleveland, OH, 242559
Contact: Steve Regovich -1 PLM Standard Phone: (216) 650-9054
Fax:
Cell:
Final Data Deliverable Email Address:
Steve.Regovich@ctconsultants.com (+ 1 ADDNL. CONTACTS)
PLM / PCM / TEM DTL RUSH PRIORITY STANDARD Air = A Bulk = B OH
Dust = D Food = F
Paint = P Soil = S
Dust RUSH PRIORITY STANDARD
*PRIOR NOTICE REQUIRED FOR SAME DAY TAT
Surface = SU Swab = SW
Tape = T Wipe = W
Metals RUSH PRIORITY STANDARD Drinking Water = DW
Waste Water = WW
Organics* SAME DAY RUSH PRIORITY STANDARD **ASTM E1792 approved wipe media only**
Viable Analysis** PRIORITY STANDARD
**TAT DEPENDENT ON SPEED OF MICROBIAL GROWTH
Medical Device Analysis RUSH STANDARD
Mold Analysis RUSH PRIORITY STANDARD
Special Instructions:
ASBESTOS CHEMISTRY MICROBIOLOGY ICO
1 Column L-12 X S
2 Column L-14 X S
3 Column L-16 X S
4 Column L-18 X S
5 Column L-23 X S
6 Column L-25 X S
7 Column L-27 X S
8 Column L-30 X S
P L
M
P L
M S h o rt R ep o rt (E
PA
/6
/R
-9 3/
6)
T E
M
P C
M
D U
S T
M E
TA
L
S
O R
G A
N
IC
S
V
IA
B L
E S
M E
D
IC
A L
M O
L D
S am pl e
V ol um e
(L
A re a
S am pl e
Te m pe ra tu re
C
Le ng th (o r A liq uo ts
) x W id th
(o r A re a/
A liq uo t)
M at rix C od e of
C on ta in er s
D at e C ol le ct ed m m
/d d/ yy
T im e C ol le ct ed hh :m m
Eurofins Built Environment Testing East, LLC establishes a unique Lab Sample ID, for each sample, by preceding each unique Client Sample ID with the laboratory RES Job Number.
Eurofins Built Environment Testing East, LLC will analyze incoming samples based on information received and will not be responsible for errors or omissions in calculations resulting from the inaccuracy of original data. By signing, client/company representative agrees that submission of the following samples for requested analysis as indicated on this Chain of Custody shall consitute an analytical services agreement with payment terms of NET 30 days. Failure to comply with payment terms may result in a 1.5% monthly interest surcharge.
Relinquished By:
Date/Time: 12/26/2024 14:58:59 Sample Condition: Acceptable
Received By:
Raegan Brown Date/Time: 12/26/2024 14:58:59 Carrier: Fed-Ex
Eurofins Built Environment Testing East, LLC Effective
Column L-12 12/16/24 1"-6" Composite Soil
Column L-14 12/16/24 1"-6" Composite Soil
Column L-16 12/16/24 1"-6" Composite Soil
Column L-18 12/16/24 1"-6" Composite Soil
Column L-23 12/16/24 1"-6" Composite Soil
Column L-25 12/16/24 1"-6" Composite Soil
Column L-27 12/16/24 1"-6" Composite Soil
Column L-30 12/16/24 1"-6" Composite Soil
CT Consultants Sample Notes
RES #: 624968
Project Number and/or P.O. #: 242559
Project Description/Location: VAMC-Cleveland, OH, 242559
Client Sample ID Sample Location
Column L-12 Sub Basement
Column L-14 Sub Basement
Column L-16 Sub Basement
Column L-18 Sub Basement
Column L-23 Sub Basement
Column L-25 Sub Basement
Column L-27 Sub Basement
Column L-30 Sub Basement
CT Consultants Sample Locations
RES #: 624968
January 06, 2025
CT Consultants 8150 Sterling Court Mentor, OH 44060
VAMC-Cleveland, OH, 242559 624940-1
Dear Steve, Enclosed are asbestos analysis results for PLM Bulk samples received at our laboratory on December 26, 2024.
The samples were analyzed for asbestos using polarizing light microscopy (PLM) per the EPA 600/R-93/116:
Method for the Determination of Asbestos in Bulk Building Materials and EPA 40 CFR Appendix E to Subpart E of Part 763: Interim Method of the Determination of Asbestos in Bulk Insulation Samples.
Sample results containing >1% asbestos are considered asbestos-containing materials (ACMs) per EPA regulatory requirements. The detection limit for the EPA 600 Method is <1% by calibrated visual estimate.
Thank you for your business and we look forward to continuing good relations.
Kind Regards, Tianbao Bai, Ph.D., CIH Laboratory Director
Prepared for
CT Consultants
CLIENT PROJECT: VAMC-Cleveland, OH, 242559
LAB CODE: 624940-1
TEST METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
Project: VAMC-Cleveland, OH, 242559
Asbestos Report Summary By: Polarized Light Microscopy
624940-1Lab Code:
EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020
Client IDClient IDClient IDClient ID Lab IDLab IDLab IDLab ID LayerLayerLayerLayer Sample DescriptionSample DescriptionSample DescriptionSample Description AsbestosAsbestosAsbestosAsbestos
Column B-30 2944018 Brown soil None DetectedNone DetectedNone DetectedNone Detected
Column D-30 2944019 Brown soil None DetectedNone DetectedNone DetectedNone Detected
Column H-30 2944020 Brown soil ChrysotileChrysotileChrysotileChrysotile
Column J-29 2944021 Brown soil None DetectedNone DetectedNone DetectedNone Detected
Column J-30 2944022 Brown soil None DetectedNone DetectedNone DetectedNone Detected
Column J-35 2944023 Brown soil None DetectedNone DetectedNone DetectedNone Detected
Project: VAMC-Cleveland, OH, 242559
Method:
Asbestos Report Summary By: Polarized Light Microscopy
624940-1Lab Code:
2752 Pleasant Road Suite 100A, • Fort Mill, SC 29708 • (803) 526-5146 Page 1 of 1Page 1 of 3
Client IDClient IDClient IDClient ID LabLabLabLab LabLabLabLab NON-ASBESTOS COMPONENTSNON-ASBESTOS COMPONENTSNON-ASBESTOS COMPONENTSNON-ASBESTOS COMPONENTS ASBESTOSASBESTOSASBESTOSASBESTOS Lab IDLab IDLab IDLab ID DescriptionDescriptionDescriptionDescription AttributesAttributesAttributesAttributes FibrousFibrousFibrousFibrous Non-FibrousNon-FibrousNon-FibrousNon-Fibrous
Column B-30Column B-30Column B-30Column B-30 2944018
Soil Homogeneous Brown Non-Fibrous Loose
+% Cellulose +%
Silica Binder Calc Carb
None DetectedNone DetectedNone DetectedNone Detected
Column D-30Column D-30Column D-30Column D-30 2944019
Soil Homogeneous Brown Non-Fibrous Loose
+% Cellulose +%
Silica Binder Calc Carb
None DetectedNone DetectedNone DetectedNone Detected
Column H-30Column H-30Column H-30Column H-30 2944020
Soil Homogeneous Brown Non-Fibrous Loose
Silica Binder Calc Carb
ChrysotileChrysotileChrysotileChrysotile
Column J-29Column J-29Column J-29Column J-29 2944021
Soil Homogeneous Brown Non-Fibrous Loose
+% Cellulose +%
Silica Binder Calc Carb
None DetectedNone DetectedNone DetectedNone Detected
Column J-30Column J-30Column J-30Column J-30 2944022
Soil Homogeneous Brown Non-Fibrous Loose
Silica Binder Calc Carb
None DetectedNone DetectedNone DetectedNone Detected
Column J-35Column J-35Column J-35Column J-35 2944023
Soil Homogeneous Brown Non-Fibrous Loose
Silica Binder Calc Carb
None DetectedNone DetectedNone DetectedNone Detected
Client: CT Consultants 8150 Sterling Court Mentor, OH 44060
Project:
Method:
ASBESTOS BULK ANALYSIS
By: Polarized Light Microscopy
624940-1 12/26/24 01/06/25 01/06/25
Lab Code:
Date Received:
Date Analyzed:
Date Reported:
VAMC-Cleveland, OH, 242559
2752 Pleasant Road Suite 100A, • Fort Mill, SC 29708 • (803) 526-5146 Page 2 of 3
REPORTING LIMIT:REPORTING LIMIT:REPORTING LIMIT:REPORTING LIMIT: <1% by visual estimation
REGULATORY LIMIT:REGULATORY LIMIT:REGULATORY LIMIT:REGULATORY LIMIT: 1% by weight
Due to the limitations of the EPA 600 / R93 / 116 method, nonfriable organically bound materials (NOBs) such as vinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request.
Eurofins Built Environment Testing East, LLC makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results. Interpretation of the analytical results is the sole responsibility of the client. This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins Built Environment Testing East, LLC. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement
Madelyn Schmidt
DATA QA:
Raegan Brown 1/6/2025
APPROVED BY:
Tianbao Bai, Ph.D., CIH
2752 Pleasant Road Suite 100A, • Fort Mill, SC 29708 • (803) 526-5146 Page 3 of 3
RES Job #: 624940
CONTACT INFORMATION SERIES
ASBESTOS LABORATORY REQUESTED ANALYSIS VALID MATRIX CODES LAB NOTES
CHEMISTRY LABORATORY
MICROBIOLOGY LABORATORY
**Turnaround times establish a laboratory priority, subject to laboratory volume and are not guaranteed. Additional fees apply for afterhours, weekends and holidays.**
Laboratory Analysis Instructions
(Sample ID's must be unique)
Project Description/Location: VAMC-Cleveland, OH, 242559
Contact: Steve Regovich -1 PLM Standard Phone: (216) 650-9054
Fax:
Cell:
Final Data Deliverable Email Address:
Steve.Regovich@ctconsultants.com (+ 1 ADDNL. CONTACTS)
PLM / PCM / TEM DTL RUSH PRIORITY STANDARD Air = A Bulk = B OH
Dust = D Food = F
Paint = P Soil = S
Dust RUSH PRIORITY STANDARD
*PRIOR NOTICE REQUIRED FOR SAME DAY TAT
Surface = SU Swab = SW
Tape = T Wipe = W
Metals RUSH PRIORITY STANDARD Drinking Water = DW
Waste Water = WW
Organics* SAME DAY RUSH PRIORITY STANDARD **ASTM E1792 approved wipe media only**
Viable Analysis** PRIORITY STANDARD
**TAT DEPENDENT ON SPEED OF MICROBIAL GROWTH
Medical Device Analysis RUSH STANDARD
1 Column B-30 X S
2 Column D-30 X S
3 Column H-30 X S
4 Column J-29 X S
5 Column J-30 X S
6 Column J-35 X S
P L
M
P L
M S h o rt R ep o rt (E
PA
/6
/R
-9 3/
6)
T E
M
P C
M
D U
S T
M E
TA
L
S
O R
G A
N
IC
S
V
IA
B L
E S
M E
D
IC
A L
M O
L D
S am pl e
V ol um e
(L
A re a
S am pl e
Te m pe ra tu re
C
Le ng th (o r A liq uo ts
) x W id th
(o r A re a/
A liq uo t)
M at rix C od e of
C on ta in er s
D at e C ol le ct ed m m
/d d/ yy
T im e C ol le ct ed hh :m m
Eurofins Built Environment Testing East, LLC establishes a unique Lab Sample ID, for each sample, by preceding each unique Client Sample ID with the laboratory RES Job Number.
Eurofins Built Environment Testing East, LLC will analyze incoming samples based on information received and will not be responsible for errors or omissions in calculations resulting from the inaccuracy of original data. By signing, client/company representative agrees that submission of the following samples for requested analysis as indicated on this Chain of Custody shall consitute an analytical services agreement with payment terms of NET 30 days. Failure to comply with payment terms may result in a 1.5% monthly interest surcharge.
Date/Time: 12/26/2024 11:37:45 Sample Condition: Acceptable
Raegan Brown Date/Time: 12/26/2024 11:37:45 Carrier: Fed-Ex
Column B-30 12/18/24 1"-6" Composite Soil
Column D-30 12/18/24 1"-6" Composite Soil
Column H-30 12/18/24 1"-6" Composite Soil
Column J-29 12/18/24 1"-6" Composite Soil
Column J-30 12/18/24 1"-6" Composite Soil
Column J-35 12/18/24 1"-6" Composite Soil
CT Consultants Sample Notes
RES #: 624940
Client Sample ID Sample Location
Column B-30 Sub Basement
Column D-30 Sub Basement
Column H-30 Sub Basement
Column J-29 Sub Basement
Column J-30 Sub Basement
Column J-35 Sub Basement
CT Consultants Sample Locations
RES #: 624940
January 03, 2025
CT Consultants 8150 Sterling Court Mentor, OH 44060
VAMC-Cleveland, OH 624981-2
Dear Steve, Enclosed are asbestos analysis results for PLM Bulk samples received at our laboratory on December 26, 2024.
The samples were analyzed for asbestos using polarizing light microscopy (PLM) per the EPA 600/R-93/116:
Method for the Determination of Asbestos in Bulk Building Materials and EPA 40 CFR Appendix E to Subpart E of Part 763: Interim Method of the Determination of Asbestos in Bulk Insulation Samples.
Sample results containing >1% asbestos are considered asbestos-containing materials (ACMs) per EPA regulatory requirements. The detection limit for the EPA 600 Method is <1% by calibrated visual estimate.
Thank you for your business and we look forward to continuing good relations.
Kind Regards, Tianbao Bai, Ph.D., CIH Laboratory Director
Prepared for
CT Consultants
CLIENT PROJECT: VAMC-Cleveland, OH
LAB CODE: 624981-2
TEST METHOD:
EPA 600 / R93 / 116 and EPA 40 CFR Appendix E to Subpart E of Part 763
REPORT DATE: 01/03/25
Project: VAMC-Cleveland, OH
ASBESTOS REPORT SUMMARY
By: Polarized Light Microscopy
624981-2Lab Code:
EPA 600 / R93 / 116 and EPA 40 CFR Appendix E to Subpart E of Part 763
Client IDClient IDClient IDClient ID Lab IDLab IDLab IDLab ID LayerLayerLayerLayer Sample DescriptionSample DescriptionSample DescriptionSample Description Asbestos %Asbestos %Asbestos %Asbestos %
01-1217-A 2956513 Beige fireproofing None DetectedNone DetectedNone…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .