S02 - Building 133.pdf
PDF 5 MB Posted
- Solicitation number
- 36C25224Q0414
About this file
This document is a Special Notice for a federal contract opportunity from the Department of Veterans Affairs (VA) for the design, specification, and construction period services required to renovate Building 133 at the Captain James A. Lovell Federal Health Care Center in North Chicago, Illinois.
The VA is seeking a single award, firm-fixed price Architect/Engineer (A/E) contract for Project #556-23-110, Building 133 Laboratory Renovation. The renovation will address the pathology and laboratory medicine services spaces, including histology, cytology, microbiology, phlebotomy, and administration areas, as well as associated utilities. The procurement is set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSBs) within a 250-mile radius of the project location. Interested firms must submit a Standard Form (SF) 330 by 10:00 am CDT on May 30, 2024. The VA will evaluate the SF 330s and hold discussions with at least the top three most highly qualified firms before selecting the most preferred firm for contract negotiations.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WALL:
DUCTS:
PENETRATIONS:
DOORS*:
WALL:
DUCTS:
DOORS:
WALL:
DUCTS:
PENETRATIONS:
DOORS:
SUITE DESIGNATION
2-HOUR FIRE BARRIER
THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND STAIRWELLS OF
4 OR MORE STORIES.
2-HOUR FIRE AND SMOKE ZONE BARRIER
THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND
STAIRWELLS OF 4 OR MORE STORIES. THIS COMBINATION WALL IS WHERE A PORTION
OF THE 2-HOUR RATED WALL IS ALSO PART OF THE SMOKE WALL.
1-HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
THIS APPLIES TO 1-HOUR FIRE RATED OCCUPANCY SEPERATIONS, HAZARDOUS ROOM
ENCLOSURES PER NFPA 101 8.6.5(2) AND STAIRWELLS 3 STORIES OR LESS. PER NFPA 101 19.3.2.1
SMOKE ZONE BARRIER
SUBSTANTIAL WALLS AND DOORS TO DIVIDE EACH FLOOR INTO COMPARTMENTS FOR
DEFEND IN PLACE EMERGENCY OPERATIONS. IF THE SMOKE ZONE BARRIER WALL IS
OF MASONRY, GYPSUM BOARD, OR METAL LATH AND PLASTER CONSTRUCTION, AND
THE BARRIER WAS CONSTRUCTED POST 1948, THE SMOKE ZONE BARRIER WALLS ARE
REQUIRED TO BE OF 1 HOUR FIRE RESISTANCE RATING. (NFPA 101, 18.3.7.6) SMOKE
ZONE BARRIER WALLS OF WOOD LATH AND PLASTER CONSTRUCTION ARE PERMITTED
TO BE OF A 12 HOUR FIRE RESISTANCE RATING (NFPA 101, 19.3.7.3)
(COLOR #5)
(COLOR #4)
(COLOR #1)
(COLOR #2)
(COLOR #3)
NOTE: ALL CODE REFERENCES ARE PER THE 2018 EDITION OF NFPA 101 LIFE SAFETY CODE AND 2019 EDITION OF NFPA 80 AND NFPA 105. FEDERAL FACILITIES FOLLOW 2018 LIFE SAFETY CODE.
DOORS: DOORS THAT ARE NOT PART OF A RATED WALL:
1. NON-LABELED FRAME (NFPA 101 18.3.6.3.1, 19.3.6.3 & 19.3.6.3.3)
2. NON-RATED DOORS PERMITTED IF SPRINKLERED (NFPA 101
18.3.6.3.1, 19.3.6.3.2(2))
3. 20-MINUTE OR SOLID WOOD CORE DOOR IF NOT SPRINKLERED (NFPA 101 19.3.6.3.1) 1 3 4" THICK.
4. POSITIVE LATCHING EXCEPT TOILETS, SHOWER AND SINK
CLOSETS (NFPA 101 18.3.6.3.6 & 19.3.6.3.6)
5. SELF-CLOSING NOT REQUIRED (NFPA 101 19.3.6.3.11)
6. NO MAXIMUM GAP (NFPA 101 18.3.6.3.1 & 19.3.6.3.3)
7. MAXIMUM 1" UNDERCUT (NFPA 101 18.3.6.3.1 & 19.3.6.3.4)
8. UNLIMITED HEIGHT PROTECTIVE PLATE (NFPA 101 18/19.3.6.3.12)
9. TRANSFER GRILLS NOT PERMITTED EXCEPT TOILETS,
SHOWER AND SINK CLOSETS (NFPA 101 18/19.3.6.4)
10. SWING IN ANY DIRECTION
11. SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA 105 5.2.5.1)
(COLOR #30)
NON-RATED SMOKE ZONE PARTITION
FORMER DECOMMISSIONED SMOKE BARRIER RETAINED AS FIRE ALARM/SPRINKLER
ZONE. BUILDING OCCUPANTS PERMITTED TO DEFEND IN PLACE UNTIL DIRECTED BY
THE FIRE DEPARTMENT PER SECTION 16.7.4.3 OF NFPA 99-2018 EDITION AND PRIVATE
MODE AUDIBLE REQUIREMENTS OF SECTION 16.7.4.3 OF NFPA 72-2019 EDITION.
WALL:
DUCTS:
PENETRATIONS:
DOORS:
HEALTH CARE OCCUPANCY CORRIDORS
IF THE SMOKE COMPARTMENT IS SPRINKLERED, THE WALL SHALL FORM A BARRIER TO LIMIT THE TRANSFER OF SMOKE. THE WALL HAS NO REQUIRED FIRE RESISTANCE RATING AND MAY TERMINATE AT A CEILING CONSTRUCTED
TO LIMIT TRANSFER OF SMOKE.
IF THE SMOKE COMPARTMENT IS NOT SPRINKLERED, THE WALLS SHALL BE CONTINUOUS FROM THE FLOOR TO THE UNDERSIDE OF THE FLOOR OR ROOF DECK ABOVE. EXISTING CORRIDOR WALL SHALL HAVE A MINIMUM 1/2 HOUR FIRE RESISTANCE RATING. DOORS ARE MANUALLY CLOSED IN AN EMERGENCY NFPA 101 18/19.3.6.2
PENETRATIONS:
WALL EXTENDS FROM FLOOR TO DECK ABOVE.
ALL DUCT PENETRATIONS ARE PROTECTED BY FIRE DAMPERS.
ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR
PROTECTING 2-HOUR WALL ASSEMBLIES. WALL PENETRATIONS ARE REQUIRED TO
BE FILLED ON BOTH SIDES OF THE WALL. FLOOR PENETRATIONS ARE ONLY
REQUIRED TO BE FILLED ON THE TOP OF THE FLOOR.
ALL DOORS REQUIRE THE FOLLOWING:
1. LABELED FRAMES (NFPA 80 4.2.1)
2. LABELED 1 1/2 HOUR DOOR (NFPA 80 4.3.1)
3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 TABLE 4.4.5)-LIMITED TO MAX AREA
TESTED.
4. POSITIVE LATCHING (NFPA 80 6.4.1.4)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)
6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)
7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" PROTECTIVE PLATE OR LABELED & LISTED (NFPA 80 6.4.5)
10. SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.3.7.6).
11. PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT LEAST
ANNUALLY (NFPA 80 5.2.4.1)
* 2 HOUR DOOR REQUIRED FOR STAIRWELLS 4 OR MORE STORIES (NFPA 101
7.1.3.2.1)(3).
WALL:
DUCTS:
PENETRATIONS:
DOORS:
WALL EXTENDS FROM FLOOR TO DECK ABOVE.
ALL DUCT PENETRATIONS ARE PROTECTED BY COMBINATION FIRE AND
SMOKE DAMPERS. SMOKE DAMPERS ARE NOT REQUIRED WHERE
ADJACENT SMOKE COMPARTMENTS ARE PROTECTED BY QUICK
RESPONSE SPRINKLERS THROUGHOUT EACH COMPARTMENT.
ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP
MATERIALS FOR PROTECTING 2-HOUR WALL ASSEMBLIES. WALL
PENETRATIONS ARE REQUIRED TO BE FILLED ON BOTH SIDES OF THE
WALL. FLOOR PENETRATIONS ARE ONLY REQUIRED TO BE FILLED ON
THE TOP OF THE FLOOR.
ALL DOORS REQUIRE THE FOLLOWING:
1. LABELED FRAMES (NFPA 80 4.2.1)
2. LABELED 1 1/2 HOUR DOOR (NFPA 80 4.3.1)
3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 4.4.5)
4. POSITIVE LATCHING (NFPA 80 6.4.1.4)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)
6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)
7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" PROTECTIVE PLATE OR LABELED & LISTED (NFPA 80
6.4.5.1)
10. SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.3.7.6).
11. PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT
LEAST ANNUALLY (NFPA 80 5.2.4.1)
WALL EXTENDS FROM FLOOR TO DECK ABOVE.
STEEL DUCT PENETRATIONS NOT REQUIRED TO BE PROTECTED BY FIRE
DAMPERS.
ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR
PROTECTING 1-HOUR WALL ASSEMBLIES. WALL PENETRATIONS ARE REQUIRED
TO BE FILLED ON BOTH SIDES OF THE WALL. FLOOR PENETRATIONS ARE ONLY
REQUIRED TO BE FILLED ON THE TOP OF THE FLOOR.
ALL DOORS REQUIRE THE FOLLOWING:
1. LABELED FRAMES (NFPA 80 4.2.1)
2. LABELED 3/4 OR 1-HOUR DOOR (NFPA 80 4.3.1)*
3. MAXIMUM AREA TESTED WINDOW (NFPA 80 TABLE 4.4.5)
4. POSITIVE LATCHING (NFPA 80 6.4.1.4)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)
6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)
7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" PROTECTIVE PLATE OR LABELED & LISTED (NFPA 80 6.4.5)
10.SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.3.7.6).
11.PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT LEAST
ANNUALLY (NFPA 80 5.2.4.1)
* 1-HOUR DOORS ARE REQUIRED IN STAIRWELLS THAT ARE 3 STORIES OR
LESS. (NFPA101 7.1.3.2.1)(1)
WALL EXTENDS FROM FLOOR TO DECK ABOVE.
ALL DUCT PENETRATIONS ARE PROTECTED BY SMOKE DAMPERS. SMOKE
DAMPERS ARE NOT REQUIRED WHERE ADJACENT SMOKE COMPARTMENTS ARE
PROTECTED BY QUICK RESPONSE SPRINKLERS THROUGHOUT EACH
COMPARTMENT.
ALL PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR
PROTECTING 1-HOUR FIRE AND SMOKE WALL ASSEMBLIES. PENETRATIONS ARE
TO BE FILLED ON BOTH SIDES OF THE WALL.
ALL DOORS FOR SMOKE BARRIERS REQUIRE THE FOLLOWING:
1. NON-LABELED FRAME (NFPA 101 18.3.7.6)
2. 20 MINUTE OR SOLID WOOD CORE (NFPA 101 18.3.7.6) 1 3 4" THICK.
3. MAXIMUM SIZE LISTED WINDOW (NFPA 80 TABLES 4.4.5)
4. POSITIVE LATCHING NOT REQUIRED (NFPA 101 18.3.7.8)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 18.3.7.8)
6. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)
7. MAXIMUM 3/4" UNDERCUT (NFPA 101 8.5.4)
8. UNLIMITED IN HEIGHT PROTECTIVE PLATE (NFPA 101 18.3.7.6/19.3.7.6.1
9. SWING IN DIRECTION OPPOSITE OF EACH OTHER (NFPA 101 18.3.7.6)
10.SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA 105
5.2.5.1)
WALL EXTENDS FROM FLOOR TO SUSPENDED CEILING OR DECK ABOVE.
NO MINIMUM REQUIREMENTS.
NO MINIMUM REQUIREMENTS FOR WALL PENETRATIONS ABOVE A SUSPENDED
CEILING. PENETRATIONS BELOW A SUSPENDED CEILING OR DECK SEALED
WITH NON-FIRE-RATED MATERIALS TO BE SMOKE RESISTIVE.
NON-FIRE-RATED DOORS AND FRAMES SELF CLOSING OR AUTOMATIC CLOSING
IN AN EMERGENCY.
(COLOR #30)
(COLOR #2)
HEALTHCARE AREA OPEN TO CORRIDOR WITH 24
SUPERVISION - NO SMOKE DETECTION REQUIRED.
(COLOR #3)
HEALTHCARE AREA OPEN TO CORRIDOR - SMOKE
DETECTION PROVIDED.
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
(COLOR #230)
(COLOR #4)
NON-FIRE RATED SMOKE BARRIER
SUBSTANTIAL WALLS AND DOORS TO SUBDIVIDE BUILDING SPACES FOR THE PURPOSE
OF RESTRICTING THE MOVEMENT OF SMOKE.
WALL: EXTENDS FROM FLOOR TO DECK ABOVE.
DUCTS: SMOKE DAMPERS ARE NOT REQUIRED WHERE STEEL DUCTS PENETRATE SMOKE
BARRIERS FORMING A COMMUNICATING SPACE SEPARATION.
PENETRATIONS: ALL PENETRATIONS ARE SEALED WITH NON-FIRE RATED MATERIALS TO PREVENT THE
TRANSFER OF SMOKE. USE OF LISTED FIRE STOP MATERIALS IS NOT REQUIRED.
DOORS: ALL DOORS FOR SMOKE BARRIERS REQUIRE THE FOLLOWING:
1. NON LABELED FRAME (NFPA 101 8.5)
2. NON FIRE RATED DOOR (NFPA 101 8.5)
3. NO GRILLS OR LOUVERS ARE PERMITTED (NFPA 101 8.5.1)
4. POSITIVE LATCHING HARDWARE IS REQUIRES (NFPA 101 8.5.4.3)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 8.5.4.43)
6. MAXIMUM ¾” UNDERCUT (NFPA 101 8.5.4.1)
7. UNLIMITED IN HEIGHT PROTECTIVE PLATE (NFPA 101 18.3.7.6/19.3.7.6.1)
8. SWING IN ANY DIRECTION (NFPA 8.5)
9. WINDOW ASSEMBLIES ARE NOT REQUIRED TO BE FIRE RATED (NFPA 8.5)
10. SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA 105 5.2.5.1)
WALL:
DUCTS:
DOORS:
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
(COLOR #230) IF THE HAZARDOUS ROOM HAS A SUSPENDED CEILING CONSTRUCTED TO LIMIT
TRANSFER OF SMOKE, THE WALL HAS NO FIRE RESISTANCE RATING AND MAY
TERMINATE AT THE CEILING PER NFPA 101 8.4.2(3). IF THE ROOM DOES NOT
HAVE A SUSPENDED CEILING, THE WALL HAS NO FIRE RESISTANCE RATING
AND SHALL EXTEND TO THE DECK ABOVE PER NFPA 101 19.3.2.1.2.
STEEL DUCT PENETRATIONS ARE NOT REQUIRED TO BE PROTECTED BY FIRE
DAMPERS OR SMOKE DAMPERS.
SEALED WITH NON-FIRE-RATED MATERIALS TO BE RESISTIVE. USE OF LISTED
FIRESTOP MATERIALS IS NOT REQUIRED.
EXISTING HAZARDOUS ROOMS:
1. NON-LABELED FRAME (NFPA 101 8.4.2)
2. 20 MINUTE OR SOLID WOOD CORE (NFPA 105 A.6.3.1) 1 3 4" THICK.
3. POSITIVE LATCHING IS REQUIRED PER (NFPA 105 6.3.4)
4. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 19.3.2.1.3)
5. MAXIMUM 1/8" GAP (NFPA 105 6.3.3)
6. MAXIMUM 3 4" UNDERCUT (NFPA 80 4.8.4.1)
7. MAXIMUM 48" PROTECTIVE PLATE (NFPA 101 19.3.2.1.4)
8. SWING IN ANY DIRECTION
9. SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA
105 5.2.5.1)
PENETRATIONS:
EW
FAAP
FACP
FIRE EXTINGUISHER
EXIT SIGN
EMERGENCY LIGHT
FIRE ALARM STATION
FIRE ALARM CONTROL PANEL
FIRE ALARM ANNUNCIATOR PANEL
AUTOMATED EXTERNAL DEFIBRILLATOR
F
AED
EYEWASH STATION
SPRINKLER SYSTEM RISER
SH SHOWER STATION
SIAMESE (FIRE DEPARTMENT CONNECTION).
FIRE HOSE VALVEFHV
SYMBOLS LIST
(COLOR #30)
EXIT STAIRWELL/PASSAGEWAY
SPRINKLER AND FIRE ALARM ZONE BOUNDARY
FIRE/SMOKE BARRIER
DESCRIPTION ALL
1786.32
DATEREVISIONS: NUMBER
DRAFT SOC 11/06/2020
FP&C Project Number Project NumberProject Title
Location
Issue Date
Drawing NumberApproved: Project Director
Drawing Title
ENGINEERS
Building Number
SITE NAME/ADDRESS
CONSULTANTS, LLC.
1520 MAIN STREET
INDIANAPOLIS, IN 46224
(317) 486-5188
FIRE PROTECTION & CODE
1/29/2021 AF KW
NORTH CHICAGO, ILLINOIS
JAMES A. LOVELL FHCC
STATEMENT OF CONDITIONS
DOCUMENTATIONJAMES A. LOVELL
FHCC
3001 Green Bay Road
North Chicago, IL 60064 Checked by Drawn by
Dwg. of 45
SOC X-1
556-20-019
FINAL SOC 1/29/2021
vhanchjuhld Text Box Building 133
BUSINESS OCCUPANCY
BUILDING 133
BUILDING 133CA
BUSINESS OCCUPANCY
BUSINESS OCCUPANCY
BUILDING 133
BUILDING 133CA
BUSINESS OCCUPANCY
HE
HE
HE
EX
HE
EX
BUSINESS OCCUPANCY
BUILDING 133EF
BUILDING 133
BUSINESS OCCUPANCY
BUSINESS OCCUPANCY
BUILDING 133EF
BUILDING 133
BUSINESS OCCUPANCY
F
AED
F
F
F
FACP
F
EX
HE
F
AED
F
F
F
F
F
F
F
FF
F
HE HE
F A
C P
UNDER
RENOVATION
BUILDING 133 BASEMENT
N
BUSINESS OCCUPANCY
FULLY SPRINKLERED
BASEMENT FLOOR
BUILDING 133
1786.32
DATEREVISIONS: NUMBER
DRAFT SOC 11/06/2020
FP&C Project Number Project NumberProject Title
Location
Issue Date
Drawing NumberApproved: Project Director
Drawing Title
ENGINEERS
Building Number
SITE NAME/ADDRESS
CONSULTANTS, LLC.
1520 MAIN STREET
INDIANAPOLIS, IN 46224
(317) 486-5188
FIRE PROTECTION & CODE
1/29/2021 AF KW
NORTH CHICAGO, ILLINOIS
JAMES A. LOVELL FHCC
STATEMENT OF CONDITIONS
DOCUMENTATIONJAMES A. LOVELL
FHCC
3001 Green Bay Road
North Chicago, IL 60064 Checked by Drawn by
Dwg. of 45
133SOC-B
AREA OPEN TO CORRIDOR WITH SMOKE DETECTION
AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED
PARTITION LEGEND
2 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE ZONE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
NON-RATED SMOKE ZONE PARTITION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
HEALTH CARE OCCUPANCY CORRIDORS
SUITE DESIGNATION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
SYMBOLS LIST
HORIZONTAL EXIT
PASSAGEWAY
EXIT
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
EP
LC
TC
EX
HE
SPRINKLER AND FIRE ALARM ZONE BOUNDARY
NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)
EXIT STAIRWELL/PASSAGEWAY
APPROVED EQUIVALENCIES
1. OVERSIZED PROTECTIVE PLATES PERMITTED ON
FIRE RATED DOORS.
2. SELF-CLOSING DOOR REQUIREMENT FOR CORRIDOR
DOORS IN A DOMICILIARY OCCUPANCY.
3. BUSINESS OCCUPANCY DEAD END CORRIDORS
PERMITTED TO EXCEED 50' FEET.
APPROVED SITE SPECIFIC EQUIVALENCIES
1. BUILDINGS 66 AND 131 - SINGLE EXIT MECHANICAL
PENTHOUSES.
2. ALL BUILDINGS - EXISTING DEAD END CORRIDORS.
556-20-019
FINAL SOC 1/29/2021
EX
EX
EX
EX
BUILDING 133CA
BUSINESS OCCUPANCY
BUILDING 133
AMBULATORY HEALTH CARE
OCCUPANCY
BUILDING 133
AMBULATORY HEALTH CARE
OCCUPANCY
BUILDING 133CA
BUSINESS OCCUPANCY
UNDER
RENOVATION
OUTPATIENT
PHARMACY
EX
1D189
OUTPATIENT
PHARMACY
1A-115A
HE
HE
LC
BUILDING 133
AMBULATORY HEALTH
CARE OCCUPANCY
BUILDING 133EF
BUSINESS OCCUPANCY
BUILDING 133
AMBULATORY HEALTH
CARE OCCUPANCY
BUILDING 133EF
BUSINESS OCCUPANCY
F
F
F
F
F
AED
AED
F
F
F
F
EX
F
F
AED
F
SZ 133-1-A1
SZ 133-1-A2
SZ 133-1-B1
SZ 133-1-B2
F
A
A
B
EX
A
A
BUILDING 133 FIRST
N
AMBULATORY HEALTH CARE OCCUPANCY
FULLY SPRINKLERED
FIRST FLOOR
BUILDING 133
DRAWING KEYNOTES:
A
1786.32
DATEREVISIONS: NUMBER
DRAFT SOC 11/06/2020
FP&C Project Number Project NumberProject Title
Location
Issue Date
Drawing NumberApproved: Project Director
Drawing Title
ENGINEERS
Building Number
SITE NAME/ADDRESS
CONSULTANTS, LLC.
1520 MAIN STREET
INDIANAPOLIS, IN 46224
(317) 486-5188
FIRE PROTECTION & CODE
1/29/2021 AF KW
NORTH CHICAGO, ILLINOIS
JAMES A. LOVELL FHCC
STATEMENT OF CONDITIONS
DOCUMENTATIONJAMES A. LOVELL
FHCC
3001 Green Bay Road
North Chicago, IL 60064 Checked by Drawn by
Dwg. of 45
133SOC-1
AREA OPEN TO CORRIDOR WITH SMOKE DETECTION
AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED
PARTITION LEGEND
2 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE ZONE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
NON-RATED SMOKE ZONE PARTITION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
HEALTH CARE OCCUPANCY CORRIDORS
SUITE DESIGNATION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
SYMBOLS LIST
HORIZONTAL EXIT
PASSAGEWAY
EXIT
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
EP
LC
TC
EX
HE
SPRINKLER AND FIRE ALARM ZONE BOUNDARY
NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)
EXIT STAIRWELL/PASSAGEWAY
APPROVED EQUIVALENCIES
1. OVERSIZED PROTECTIVE PLATES PERMITTED ON
FIRE RATED DOORS.
2. SELF-CLOSING DOOR REQUIREMENT FOR CORRIDOR
DOORS IN A DOMICILIARY OCCUPANCY.
3. BUSINESS OCCUPANCY DEAD END CORRIDORS
PERMITTED TO EXCEED 50' FEET.
APPROVED SITE SPECIFIC EQUIVALENCIES
1. BUILDINGS 66 AND 131 - SINGLE EXIT MECHANICAL
PENTHOUSES.
2. ALL BUILDINGS - EXISTING DEAD END CORRIDORS.
556-20-019
FINAL SOC 1/29/2021
SUITE DESCRIPTIONS
SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER
B
SMOKE ZONE SQ. FT. OCCUPANCY
SMOKE ZONE SIZE
HEALTH CARE OCCUPANCY
BUILDING 133CA
HEALTH CARE OCCUPANCY
BUILDING 133
HEALTH CARE OCCUPANCY
BUILDING 133CA
AMBULATORY HEALTH CARE
OCCUPANCY
HE
HE
HE
LC
HEALTH CARE OCCUPANCY
BUILDING 133EF
BUILDING 133
BUSINESS OCCUPANCY
HEALTH CARE OCCUPANCY
BUILDING 133EF
BUILDING 133
BUSINESS OCCUPANCY
F
F
F
F
F
A E
D
F
A E
D
A E
D
F
F
F
F
SZ 133-2-A1
SZ 133-2-A2
SZ 133CA-2-D
SZ 133CA-2-C
SZ 133-2-A2 SZ 133-2-B
A
A
SZ 133-2-A2
SZ 133-2-C
UNDER
RENOVATION
SZ 133CA-2-A
A
B
BUILDING 133 SECOND
N
HEALTH CARE OCCUPANCY
FULLY SPRINKLERED
BUILDING 133
DRAWING KEYNOTES:
A
1786.32
DATEREVISIONS: NUMBER
DRAFT SOC 11/06/2020
FP&C Project Number Project NumberProject Title
Location
Issue Date
Drawing NumberApproved: Project Director
Drawing Title
ENGINEERS
Building Number
SITE NAME/ADDRESS
CONSULTANTS, LLC.
1520 MAIN STREET
INDIANAPOLIS, IN 46224
(317) 486-5188
FIRE PROTECTION & CODE
1/29/2021 AF KW
NORTH CHICAGO, ILLINOIS
JAMES A. LOVELL FHCC
STATEMENT OF CONDITIONS
DOCUMENTATIONJAMES A. LOVELL
FHCC
3001 Green Bay Road
North Chicago, IL 60064 Checked by Drawn by
Dwg. of 45
133SOC-2
AREA OPEN TO CORRIDOR WITH SMOKE DETECTION
AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED
PARTITION LEGEND
2 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE ZONE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
NON-RATED SMOKE ZONE PARTITION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
HEALTH CARE OCCUPANCY CORRIDORS
SUITE DESIGNATION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
SYMBOLS LIST
HORIZONTAL EXIT
PASSAGEWAY
EXIT
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
EP
LC
TC
EX
HE
SPRINKLER AND FIRE ALARM ZONE BOUNDARY
NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)
EXIT STAIRWELL/PASSAGEWAY
APPROVED EQUIVALENCIES
1. OVERSIZED PROTECTIVE PLATES PERMITTED ON
FIRE RATED DOORS.
2. SELF-CLOSING DOOR REQUIREMENT FOR CORRIDOR
DOORS IN A DOMICILIARY OCCUPANCY.
3. BUSINESS OCCUPANCY DEAD END CORRIDORS
PERMITTED TO EXCEED 50' FEET.
APPROVED SITE SPECIFIC EQUIVALENCIES
1. BUILDINGS 66 AND 131 - SINGLE EXIT MECHANICAL
PENTHOUSES.
2. ALL BUILDINGS - EXISTING DEAD END CORRIDORS.
556-20-019
FINAL SOC 1/29/2021
SECOND FLOOR
SUITE DESCRIPTIONS
SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER
BUSINESS OCCUPANCY
BUILDING 133CA
HEALTH CARE OCCUPANCY
BUSINESS OCCUPANCY
BUILDING 133
BUILDING 133CA
HEALTH CARE OCCUPANCY
1 2
HE
LC
HEALTH CARE OCCUPANCY
BUILDING 133EF
BUILDING 133
BUSINESS OCCUPANCY
HEALTH CARE OCCUPANCY
BUILDING 133EF
BUILDING 133
BUSINESS OCCUPANCY
F
F F
F
F
AED
AED
F
AED
F
AED
F
A
F F
F
SZ 133-3-A SZ 133-3-B
SZ 133-3-B SZ 133-3-C
A
UNDER
RENOVATION
BUILDING 133 THIRD
N
HEALTH CARE OCCUPANCY
FULLY SPRINKLERED
BUILDING 133
DRAWING KEYNOTES:
A
1786.32
DATEREVISIONS: NUMBER
DRAFT SOC 11/06/2020
FP&C Project Number Project NumberProject Title
Location
Issue Date
Drawing NumberApproved: Project Director
Drawing Title
ENGINEERS
Building Number
SITE NAME/ADDRESS
CONSULTANTS, LLC.
1520 MAIN STREET
INDIANAPOLIS, IN 46224
(317) 486-5188
FIRE PROTECTION & CODE
1/29/2021 AF KW
NORTH CHICAGO, ILLINOIS
JAMES A. LOVELL FHCC
STATEMENT OF CONDITIONS
DOCUMENTATIONJAMES A. LOVELL
FHCC
3001 Green Bay Road
North Chicago, IL 60064 Checked by Drawn by
Dwg. of 45
133SOC-3
AREA OPEN TO CORRIDOR WITH SMOKE DETECTION
AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED
PARTITION LEGEND
2 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE ZONE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
NON-RATED SMOKE ZONE PARTITION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
HEALTH CARE OCCUPANCY CORRIDORS
SUITE DESIGNATION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
SYMBOLS LIST
HORIZONTAL EXIT
PASSAGEWAY
EXIT
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
EP
LC
TC
EX
HE
SPRINKLER AND FIRE ALARM ZONE BOUNDARY
NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)
EXIT STAIRWELL/PASSAGEWAY
APPROVED EQUIVALENCIES
1. OVERSIZED PROTECTIVE PLATES PERMITTED ON
FIRE RATED DOORS.
2. SELF-CLOSING DOOR REQUIREMENT FOR CORRIDOR
DOORS IN A DOMICILIARY OCCUPANCY.
3. BUSINESS OCCUPANCY DEAD END CORRIDORS
PERMITTED TO EXCEED 50' FEET.
APPROVED SITE SPECIFIC EQUIVALENCIES
1. BUILDINGS 66 AND 131 - SINGLE EXIT MECHANICAL
PENTHOUSES.
2. ALL BUILDINGS - EXISTING DEAD END CORRIDORS.
556-20-019
FINAL SOC 1/29/2021
THIRD FLOOR
SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER
SUITE DESCRIPTIONS
STAIR
HALL
NO. 2
HOPTEL
ROOM
4A-144
4A-145
PATIENT
ROOM
BATH
4A-145A BATH
4A-146A
PATIENT
ROOM
4A-146
PATIENT
ROOM
4A-147
BATH
4A-147A
MED/
SURG
BEDROOM,
2 BED
4A-148
BATH
4A-148A
PHYS.
CHART.
4A-149
SUPP.
C4-111A
MEDS.
4A-151A
NOUR.
4A-150
NURSE
SUB
STATION
4A-151
CONF./
REPORT
4A-152
STORAGE
EQUIP.
4A-153
BATH
4A-155B
TOILET
STAFF
4A-154
HAC
4A-155A
PEDS
ISO
BEDROOM
NEG.
4A-155A
CR.
CRT.
C4-111C
SUPP.
C4-111B
CHART.
SAT.
C4-111D
BATH
4A-144A
BATH
4A-143A
PATIENT
ROOM
4A-143
PATIENT
ROOM
4A-142 BATH
4A-142A
BATH
4A-141A
CHART.
SAT.
C4-111E
CORRIDOR
C4-111
PATIENT
ROOM
4A-141
TEL
DATA
4A-140UTILITY
RM.
SOILED
4A-137
CLEAN
SUPPLY
4A-139
ELEC.
CLO.
4A-136
ANTERM.
NEG.
ISO
4A-135A
LIN.
RM.
CLEAN
4A-128
CHART.
SAT.
C4-106A
PATIENT
ROOM
4A-127
BATH
4A-127A
BATH
4A-130A
PATIENT
RM. ISO
NEG.
PRESS.
4A-135
BATH
4A-135B
PATIENT
ROOM
4A-130
BATH
4A-126A
PATIENT
ROOM
4A-131
BATH
4A-131A
C O
R R
ID
O
R C
4-
PATIENT
ROOM
4A-134
BATH
4A-134A
CHART.
SAT.
C4-110B
SUPP.
C4-110A
BATH
4A-132A
CHART
ROOM
4A-134B
PATIENT
ROOM
4A-132
STAIR
HALL
NO. 6
STORAGE
EQUIP.
4A-103
BREAK
RM.
STAFF
4A-104
TOILET
WMN
STAFF
4A-112
TOILET
MN
STAFF
4A-110
STAFF
LOCKER
RM.
4A-105
OFFICE
OTHER
4A-106
BREAK
RM.
RESIDENT4A-107
RESIDENCY
CONF./
CLASSRM.
4A-108
CUBICLE
DIET./
PHARM.
4A-109
OFFICE
PHYS.
4A-111
OFFICE
NURSE
SUP.
4A-113
C O
R R
ID
O
R C
4-
CORRIDOR
C4-104
STOR.
4A-108A
C O
R R
ID
O
R C
4-
LIN.
CHUTE
4A-114
PATIENT
ROOM
4A-126
PEDS
BEDROOM
4A-155C
TOILET
PUBLIC
- WMN
4A-117
TOILET
PUBLIC
-MN
4A-116
CUBICLE,
ADMIN.
4A-123,A,B & C
FAMILY
WAIT.
4A-124
BATH
4A-155D
DOCTORS
CHART
ROOM
4A-155
TOILET
STAFF
4A-102
HAC
4A-101
CONSULT.
4A-115
LIN.
RM.
CLEAN
4A-125A
PATIENT
ROOM
4A-122
PATIENT
ROOM
4A-119
ELEC.
4A-118
FEC.
ELEC.
4A-100
CORRIDOR
C4-106
ELEV.
LOBBY
C4-100
STAIR
HALL
NO.1
C O
R R
ID
O
R C
4-
CORRIDOR
C4-102
EXAM/TRTMNT.
4A-125
CHART.
SAT.
C4-107I
WHL
CHAIR
C4-107H
PATIENT
ROOM
4A-121
PATIENT
ROOM
4A-120
SUPP.
C4-107B
PATIENT
ROOM
4B-122 PATIENT
ROOM
4B-120
PATIENT
ROOM
4B-121
PATIENT
ROOM
4B-119
PATIENT
RM. ISO.
NEG.
PRESS.
4B-123
TOILET
STAFF
4B-118
ANTERM. -
NEG. ISO
4B-123A
HAC
4B-124
DATA &
TELE
4B-117
ELEC.
4B-116
CHART.
SAT.
C4-109B
SUPP.
C4-107A
BATH
4A-119A
PATIENT
ROOM
4B-106
BATH
4A-120A
BATH
4A-122A
BATH
4A-121A
NURSE
SUB
STATION
4B-101
CONF./
REPORT
4B-100
MEDS.
4B-101A
NOUR.
4B-102
BATH
4B-122A
BATH
4B-120A
BATH
4B-119A
BATH
4B-121A
BATH
4B-123B
SUPP
C4-109A
C O
R R
ID
O
R C
4-
C
O R
R
ID
O R
C 4-
PATIENT
ROOM
4B-108
CHART.
SAT.
C4-107F
PATIENT
ROOM
4B-109
PATIENT
ROOM
4B-107
SUPP.
C4-107E
CHART.
SAT.
C4-107G
PATIENT
ROOM
4B-105
PATIENT
ROOM
4B-104
LINEN
4B-103
UTILITY
RM.
SOILED
4B-113
CLEAN
SUPPLY
4B-115
PATIENT
ROOM
4B-111
PATIENT
ROOM
4B-110
SUPP.
C4-107C
BATH
4B-111A
BATH
4B-110A
BATH
4B-105A
BATH
4B-104A BATH
4B-106A
BATH
4B-107A
BATH
4B-109A
BATH
4B-108A
DATA
TEL.
4B-112
CR
CRT
C4-107D FEC
CORRIDOR
C4-107
STAIR
HALL
NO. 5
ROOF BELOWROOF BELOWROOF BELOW
HEALTH CARE OCCUPANCY
BUILDING 133EF
BUILDING 133
INDUSTRIAL OCCUPANCY
HEALTH CARE OCCUPANCY
BUILDING 133EF
BUILDING 133
INDUSTRIAL OCCUPANCY
F
F
F
AED
F
F
F
F
SZ 133-4-A SZ 133-4-B
SZ 133-4-B SZ 133-4-C
UNDER
RENOVATION
BUILDING 133 FOURTH
N
HEALTH CARE OCCUPANCY
FULLY SPRINKLERED
BUILDING 133 & 133CA
133 & 133CA
1786.32
DATEREVISIONS: NUMBER
DRAFT SOC 11/06/2020
FP&C Project Number Project NumberProject Title
Location
Issue Date
Drawing NumberApproved: Project Director
Drawing Title
ENGINEERS
Building Number
SITE NAME/ADDRESS
CONSULTANTS, LLC.
1520 MAIN STREET
INDIANAPOLIS, IN 46224
(317) 486-5188
FIRE PROTECTION & CODE
1/29/2021 AF KW
NORTH CHICAGO, ILLINOIS
JAMES A. LOVELL FHCC
STATEMENT OF CONDITIONS
DOCUMENTATIONJAMES A. LOVELL
FHCC
3001 Green Bay Road
North Chicago, IL 60064 Checked by Drawn by
Dwg. of 45
133SOC-4
AREA OPEN TO CORRIDOR WITH SMOKE DETECTION
AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED
PARTITION LEGEND
2 HOUR FIRE BARRIER
2 HOUR FIRE/SMOKE ZONE BARRIER
SMOKE ZONE BARRIER
1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)
NON-RATED SMOKE ZONE PARTITION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
HEALTH CARE OCCUPANCY CORRIDORS
SUITE DESIGNATION
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE
SYMBOLS LIST
HORIZONTAL EXIT
PASSAGEWAY
EXIT
EXIT PASSAGEWAY
LINEN CHUTE
TRASH CHUTE
EP
LC
TC
EX
HE
SPRINKLER AND FIRE ALARM ZONE BOUNDARY
NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)
EXIT STAIRWELL/PASSAGEWAY
APPROVED EQUIVALENCIES
1. OVERSIZED PROTECTIVE PLATES PERMITTED ON
FIRE RATED DOORS.
2. SELF-CLOSING DOOR REQUIREMENT FOR CORRIDOR
DOORS IN A DOMICILIARY OCCUPANCY.
3. BUSINESS OCCUPANCY DEAD END CORRIDORS
PERMITTED TO EXCEED 50' FEET.
APPROVED SITE SPECIFIC EQUIVALENCIES
1. BUILDINGS 66 AND 131 - SINGLE EXIT MECHANICAL
PENTHOUSES.
2. ALL BUILDINGS - EXISTING DEAD END CORRIDORS.
556-20-019
FINAL SOC 1/29/2021
FOURTH FLOOR
SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER
SUITE DESCRIPTIONS
| FHCC VA NORTH CHICAGO 1 |
| FHCC VA NORTH CHICAGO 16 |
| FHCC VA NORTH CHICAGO 20 |
| FHCC VA NORTH CHICAGO 24 |
| FHCC VA NORTH CHICAGO 28 |
| FHCC VA NORTH CHICAGO 32 |
File details come from the government source that posted it. Updated .