S02 - Building 133.pdf

PDF 5 MB Posted

Attached to
C1DA--0007: A/E Bldg 133 Lab Service Renovation 556-23-110 (VA-24-00009483)
Solicitation number
36C25224Q0414
Issued by

About this file

This document is a Special Notice for a federal contract opportunity from the Department of Veterans Affairs (VA) for the design, specification, and construction period services required to renovate Building 133 at the Captain James A. Lovell Federal Health Care Center in North Chicago, Illinois.

The VA is seeking a single award, firm-fixed price Architect/Engineer (A/E) contract for Project #556-23-110, Building 133 Laboratory Renovation. The renovation will address the pathology and laboratory medicine services spaces, including histology, cytology, microbiology, phlebotomy, and administration areas, as well as associated utilities. The procurement is set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSBs) within a 250-mile radius of the project location. Interested firms must submit a Standard Form (SF) 330 by 10:00 am CDT on May 30, 2024. The VA will evaluate the SF 330s and hold discussions with at least the top three most highly qualified firms before selecting the most preferred firm for contract negotiations.

View the file

Other files

File Type Posted
36C25224Q0414 0007.docx DOCX document
36C25224Q0414 0006.docx DOCX document
36C25224Q0414 0005.docx DOCX document
S06 - 556-B55 HVAC Record Dwgs Part 2.pdf PDF
S06 - 556-B55 HVAC Record Dwgs Part 1.pdf PDF
S06 - 556-B55 HVAC As-Built Dwgs Part 2.pdf PDF
36C25224Q0414 0004.docx DOCX document
S06 - 556-B55 HVAC As-Built Dwgs Part 3.pdf PDF
S06 - 556-B55 HVAC As-Built Dwgs Part 1.pdf PDF
36C25224Q0414 0003.docx DOCX document
S06 - VA Medical Center Alterations Volume 2.pdf PDF
S06 - VA Medical Center Alterations Volume 1.pdf PDF
S06 - 556-B55 Electrical Record Dwgs Part 1.pdf PDF
S06 - 556-B55 Electrical Record Dwgs Part 2.pdf PDF
36C25224Q0414 0002.docx DOCX document
S02 - 556-B55 Architectural Record Dwgs Part 1.pdf PDF
36C25224Q0414 0001.docx DOCX document
S02 - 556-B55 Architectural Record Dwgs Part 2.pdf PDF
S02 - 556-B55 Structural STD Record Dwgs.pdf PDF
S02 - 556-B55 Structural Record Dwgs.pdf PDF
S02 - 556-B55 Site Utilities Record Dwgs.pdf PDF
36C25224Q0414.docx DOCX document
S02 - Attachment 1 FHCC Specs.pdf PDF
S02 - 556-B55 Plumbing Record Dwgs.pdf PDF
S02 - Building 133 Report Narrative 12_19_11.pdf PDF
S02 - FCA Review Report Bldg 133.pdf PDF
S02 - 556-23-110 Laboratory Services Renovation AE SOW 8DEC23.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WALL:

DUCTS:

PENETRATIONS:

DOORS*:

WALL:

DUCTS:

DOORS:

WALL:

DUCTS:

PENETRATIONS:

DOORS:

SUITE DESIGNATION

2-HOUR FIRE BARRIER

THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND STAIRWELLS OF

4 OR MORE STORIES.

2-HOUR FIRE AND SMOKE ZONE BARRIER

THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND

STAIRWELLS OF 4 OR MORE STORIES. THIS COMBINATION WALL IS WHERE A PORTION

OF THE 2-HOUR RATED WALL IS ALSO PART OF THE SMOKE WALL.

1-HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

THIS APPLIES TO 1-HOUR FIRE RATED OCCUPANCY SEPERATIONS, HAZARDOUS ROOM

ENCLOSURES PER NFPA 101 8.6.5(2) AND STAIRWELLS 3 STORIES OR LESS. PER NFPA 101 19.3.2.1

SMOKE ZONE BARRIER

SUBSTANTIAL WALLS AND DOORS TO DIVIDE EACH FLOOR INTO COMPARTMENTS FOR

DEFEND IN PLACE EMERGENCY OPERATIONS. IF THE SMOKE ZONE BARRIER WALL IS

OF MASONRY, GYPSUM BOARD, OR METAL LATH AND PLASTER CONSTRUCTION, AND

THE BARRIER WAS CONSTRUCTED POST 1948, THE SMOKE ZONE BARRIER WALLS ARE

REQUIRED TO BE OF 1 HOUR FIRE RESISTANCE RATING. (NFPA 101, 18.3.7.6) SMOKE

ZONE BARRIER WALLS OF WOOD LATH AND PLASTER CONSTRUCTION ARE PERMITTED

TO BE OF A 12 HOUR FIRE RESISTANCE RATING (NFPA 101, 19.3.7.3)

(COLOR #5)

(COLOR #4)

(COLOR #1)

(COLOR #2)

(COLOR #3)

NOTE: ALL CODE REFERENCES ARE PER THE 2018 EDITION OF NFPA 101 LIFE SAFETY CODE AND 2019 EDITION OF NFPA 80 AND NFPA 105. FEDERAL FACILITIES FOLLOW 2018 LIFE SAFETY CODE.

DOORS: DOORS THAT ARE NOT PART OF A RATED WALL:

1. NON-LABELED FRAME (NFPA 101 18.3.6.3.1, 19.3.6.3 & 19.3.6.3.3)

2. NON-RATED DOORS PERMITTED IF SPRINKLERED (NFPA 101

18.3.6.3.1, 19.3.6.3.2(2))

3. 20-MINUTE OR SOLID WOOD CORE DOOR IF NOT SPRINKLERED (NFPA 101 19.3.6.3.1) 1 3 4" THICK.

4. POSITIVE LATCHING EXCEPT TOILETS, SHOWER AND SINK

CLOSETS (NFPA 101 18.3.6.3.6 & 19.3.6.3.6)

5. SELF-CLOSING NOT REQUIRED (NFPA 101 19.3.6.3.11)

6. NO MAXIMUM GAP (NFPA 101 18.3.6.3.1 & 19.3.6.3.3)

7. MAXIMUM 1" UNDERCUT (NFPA 101 18.3.6.3.1 & 19.3.6.3.4)

8. UNLIMITED HEIGHT PROTECTIVE PLATE (NFPA 101 18/19.3.6.3.12)

9. TRANSFER GRILLS NOT PERMITTED EXCEPT TOILETS,

SHOWER AND SINK CLOSETS (NFPA 101 18/19.3.6.4)

10. SWING IN ANY DIRECTION

11. SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA 105 5.2.5.1)

(COLOR #30)

NON-RATED SMOKE ZONE PARTITION

FORMER DECOMMISSIONED SMOKE BARRIER RETAINED AS FIRE ALARM/SPRINKLER

ZONE. BUILDING OCCUPANTS PERMITTED TO DEFEND IN PLACE UNTIL DIRECTED BY

THE FIRE DEPARTMENT PER SECTION 16.7.4.3 OF NFPA 99-2018 EDITION AND PRIVATE

MODE AUDIBLE REQUIREMENTS OF SECTION 16.7.4.3 OF NFPA 72-2019 EDITION.

WALL:

DUCTS:

PENETRATIONS:

DOORS:

HEALTH CARE OCCUPANCY CORRIDORS

IF THE SMOKE COMPARTMENT IS SPRINKLERED, THE WALL SHALL FORM A BARRIER TO LIMIT THE TRANSFER OF SMOKE. THE WALL HAS NO REQUIRED FIRE RESISTANCE RATING AND MAY TERMINATE AT A CEILING CONSTRUCTED

TO LIMIT TRANSFER OF SMOKE.

IF THE SMOKE COMPARTMENT IS NOT SPRINKLERED, THE WALLS SHALL BE CONTINUOUS FROM THE FLOOR TO THE UNDERSIDE OF THE FLOOR OR ROOF DECK ABOVE. EXISTING CORRIDOR WALL SHALL HAVE A MINIMUM 1/2 HOUR FIRE RESISTANCE RATING. DOORS ARE MANUALLY CLOSED IN AN EMERGENCY NFPA 101 18/19.3.6.2

PENETRATIONS:

WALL EXTENDS FROM FLOOR TO DECK ABOVE.

ALL DUCT PENETRATIONS ARE PROTECTED BY FIRE DAMPERS.

ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR

PROTECTING 2-HOUR WALL ASSEMBLIES. WALL PENETRATIONS ARE REQUIRED TO

BE FILLED ON BOTH SIDES OF THE WALL. FLOOR PENETRATIONS ARE ONLY

REQUIRED TO BE FILLED ON THE TOP OF THE FLOOR.

ALL DOORS REQUIRE THE FOLLOWING:

1. LABELED FRAMES (NFPA 80 4.2.1)

2. LABELED 1 1/2 HOUR DOOR (NFPA 80 4.3.1)

3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 TABLE 4.4.5)-LIMITED TO MAX AREA

TESTED.

4. POSITIVE LATCHING (NFPA 80 6.4.1.4)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)

6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)

7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)

8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)

9. MAXIMUM 16" PROTECTIVE PLATE OR LABELED & LISTED (NFPA 80 6.4.5)

10. SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.3.7.6).

11. PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT LEAST

ANNUALLY (NFPA 80 5.2.4.1)

* 2 HOUR DOOR REQUIRED FOR STAIRWELLS 4 OR MORE STORIES (NFPA 101

7.1.3.2.1)(3).

WALL:

DUCTS:

PENETRATIONS:

DOORS:

WALL EXTENDS FROM FLOOR TO DECK ABOVE.

ALL DUCT PENETRATIONS ARE PROTECTED BY COMBINATION FIRE AND

SMOKE DAMPERS. SMOKE DAMPERS ARE NOT REQUIRED WHERE

ADJACENT SMOKE COMPARTMENTS ARE PROTECTED BY QUICK

RESPONSE SPRINKLERS THROUGHOUT EACH COMPARTMENT.

ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP

MATERIALS FOR PROTECTING 2-HOUR WALL ASSEMBLIES. WALL

PENETRATIONS ARE REQUIRED TO BE FILLED ON BOTH SIDES OF THE

WALL. FLOOR PENETRATIONS ARE ONLY REQUIRED TO BE FILLED ON

THE TOP OF THE FLOOR.

ALL DOORS REQUIRE THE FOLLOWING:

1. LABELED FRAMES (NFPA 80 4.2.1)

2. LABELED 1 1/2 HOUR DOOR (NFPA 80 4.3.1)

3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 4.4.5)

4. POSITIVE LATCHING (NFPA 80 6.4.1.4)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)

6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)

7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)

8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)

9. MAXIMUM 16" PROTECTIVE PLATE OR LABELED & LISTED (NFPA 80

6.4.5.1)

10. SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.3.7.6).

11. PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT

LEAST ANNUALLY (NFPA 80 5.2.4.1)

WALL EXTENDS FROM FLOOR TO DECK ABOVE.

STEEL DUCT PENETRATIONS NOT REQUIRED TO BE PROTECTED BY FIRE

DAMPERS.

ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR

PROTECTING 1-HOUR WALL ASSEMBLIES. WALL PENETRATIONS ARE REQUIRED

TO BE FILLED ON BOTH SIDES OF THE WALL. FLOOR PENETRATIONS ARE ONLY

REQUIRED TO BE FILLED ON THE TOP OF THE FLOOR.

ALL DOORS REQUIRE THE FOLLOWING:

1. LABELED FRAMES (NFPA 80 4.2.1)

2. LABELED 3/4 OR 1-HOUR DOOR (NFPA 80 4.3.1)*

3. MAXIMUM AREA TESTED WINDOW (NFPA 80 TABLE 4.4.5)

4. POSITIVE LATCHING (NFPA 80 6.4.1.4)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)

6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)

7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)

8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)

9. MAXIMUM 16" PROTECTIVE PLATE OR LABELED & LISTED (NFPA 80 6.4.5)

10.SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.3.7.6).

11.PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT LEAST

ANNUALLY (NFPA 80 5.2.4.1)

* 1-HOUR DOORS ARE REQUIRED IN STAIRWELLS THAT ARE 3 STORIES OR

LESS. (NFPA101 7.1.3.2.1)(1)

WALL EXTENDS FROM FLOOR TO DECK ABOVE.

ALL DUCT PENETRATIONS ARE PROTECTED BY SMOKE DAMPERS. SMOKE

DAMPERS ARE NOT REQUIRED WHERE ADJACENT SMOKE COMPARTMENTS ARE

PROTECTED BY QUICK RESPONSE SPRINKLERS THROUGHOUT EACH

COMPARTMENT.

ALL PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR

PROTECTING 1-HOUR FIRE AND SMOKE WALL ASSEMBLIES. PENETRATIONS ARE

TO BE FILLED ON BOTH SIDES OF THE WALL.

ALL DOORS FOR SMOKE BARRIERS REQUIRE THE FOLLOWING:

1. NON-LABELED FRAME (NFPA 101 18.3.7.6)

2. 20 MINUTE OR SOLID WOOD CORE (NFPA 101 18.3.7.6) 1 3 4" THICK.

3. MAXIMUM SIZE LISTED WINDOW (NFPA 80 TABLES 4.4.5)

4. POSITIVE LATCHING NOT REQUIRED (NFPA 101 18.3.7.8)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 18.3.7.8)

6. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7)

7. MAXIMUM 3/4" UNDERCUT (NFPA 101 8.5.4)

8. UNLIMITED IN HEIGHT PROTECTIVE PLATE (NFPA 101 18.3.7.6/19.3.7.6.1

9. SWING IN DIRECTION OPPOSITE OF EACH OTHER (NFPA 101 18.3.7.6)

10.SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA 105

5.2.5.1)

WALL EXTENDS FROM FLOOR TO SUSPENDED CEILING OR DECK ABOVE.

NO MINIMUM REQUIREMENTS.

NO MINIMUM REQUIREMENTS FOR WALL PENETRATIONS ABOVE A SUSPENDED

CEILING. PENETRATIONS BELOW A SUSPENDED CEILING OR DECK SEALED

WITH NON-FIRE-RATED MATERIALS TO BE SMOKE RESISTIVE.

NON-FIRE-RATED DOORS AND FRAMES SELF CLOSING OR AUTOMATIC CLOSING

IN AN EMERGENCY.

(COLOR #30)

(COLOR #2)

HEALTHCARE AREA OPEN TO CORRIDOR WITH 24

SUPERVISION - NO SMOKE DETECTION REQUIRED.

(COLOR #3)

HEALTHCARE AREA OPEN TO CORRIDOR - SMOKE

DETECTION PROVIDED.

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

(COLOR #230)

(COLOR #4)

NON-FIRE RATED SMOKE BARRIER

SUBSTANTIAL WALLS AND DOORS TO SUBDIVIDE BUILDING SPACES FOR THE PURPOSE

OF RESTRICTING THE MOVEMENT OF SMOKE.

WALL: EXTENDS FROM FLOOR TO DECK ABOVE.

DUCTS: SMOKE DAMPERS ARE NOT REQUIRED WHERE STEEL DUCTS PENETRATE SMOKE

BARRIERS FORMING A COMMUNICATING SPACE SEPARATION.

PENETRATIONS: ALL PENETRATIONS ARE SEALED WITH NON-FIRE RATED MATERIALS TO PREVENT THE

TRANSFER OF SMOKE. USE OF LISTED FIRE STOP MATERIALS IS NOT REQUIRED.

DOORS: ALL DOORS FOR SMOKE BARRIERS REQUIRE THE FOLLOWING:

1. NON LABELED FRAME (NFPA 101 8.5)

2. NON FIRE RATED DOOR (NFPA 101 8.5)

3. NO GRILLS OR LOUVERS ARE PERMITTED (NFPA 101 8.5.1)

4. POSITIVE LATCHING HARDWARE IS REQUIRES (NFPA 101 8.5.4.3)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 8.5.4.43)

6. MAXIMUM ¾” UNDERCUT (NFPA 101 8.5.4.1)

7. UNLIMITED IN HEIGHT PROTECTIVE PLATE (NFPA 101 18.3.7.6/19.3.7.6.1)

8. SWING IN ANY DIRECTION (NFPA 8.5)

9. WINDOW ASSEMBLIES ARE NOT REQUIRED TO BE FIRE RATED (NFPA 8.5)

10. SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA 105 5.2.5.1)

WALL:

DUCTS:

DOORS:

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

(COLOR #230) IF THE HAZARDOUS ROOM HAS A SUSPENDED CEILING CONSTRUCTED TO LIMIT

TRANSFER OF SMOKE, THE WALL HAS NO FIRE RESISTANCE RATING AND MAY

TERMINATE AT THE CEILING PER NFPA 101 8.4.2(3). IF THE ROOM DOES NOT

HAVE A SUSPENDED CEILING, THE WALL HAS NO FIRE RESISTANCE RATING

AND SHALL EXTEND TO THE DECK ABOVE PER NFPA 101 19.3.2.1.2.

STEEL DUCT PENETRATIONS ARE NOT REQUIRED TO BE PROTECTED BY FIRE

DAMPERS OR SMOKE DAMPERS.

SEALED WITH NON-FIRE-RATED MATERIALS TO BE RESISTIVE. USE OF LISTED

FIRESTOP MATERIALS IS NOT REQUIRED.

EXISTING HAZARDOUS ROOMS:

1. NON-LABELED FRAME (NFPA 101 8.4.2)

2. 20 MINUTE OR SOLID WOOD CORE (NFPA 105 A.6.3.1) 1 3 4" THICK.

3. POSITIVE LATCHING IS REQUIRED PER (NFPA 105 6.3.4)

4. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 19.3.2.1.3)

5. MAXIMUM 1/8" GAP (NFPA 105 6.3.3)

6. MAXIMUM 3 4" UNDERCUT (NFPA 80 4.8.4.1)

7. MAXIMUM 48" PROTECTIVE PLATE (NFPA 101 19.3.2.1.4)

8. SWING IN ANY DIRECTION

9. SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA

105 5.2.5.1)

PENETRATIONS:

EW

FAAP

FACP

FIRE EXTINGUISHER

EXIT SIGN

EMERGENCY LIGHT

FIRE ALARM STATION

FIRE ALARM CONTROL PANEL

FIRE ALARM ANNUNCIATOR PANEL

AUTOMATED EXTERNAL DEFIBRILLATOR

F

AED

EYEWASH STATION

SPRINKLER SYSTEM RISER

SH SHOWER STATION

SIAMESE (FIRE DEPARTMENT CONNECTION).

FIRE HOSE VALVEFHV

SYMBOLS LIST

(COLOR #30)

EXIT STAIRWELL/PASSAGEWAY

SPRINKLER AND FIRE ALARM ZONE BOUNDARY

FIRE/SMOKE BARRIER

DESCRIPTION ALL

1786.32

DATEREVISIONS: NUMBER

DRAFT SOC 11/06/2020

FP&C Project Number Project NumberProject Title

Location

Issue Date

Drawing NumberApproved: Project Director

Drawing Title

ENGINEERS

Building Number

SITE NAME/ADDRESS

CONSULTANTS, LLC.

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE

1/29/2021 AF KW

NORTH CHICAGO, ILLINOIS

JAMES A. LOVELL FHCC

STATEMENT OF CONDITIONS

DOCUMENTATIONJAMES A. LOVELL

FHCC

3001 Green Bay Road

North Chicago, IL 60064 Checked by Drawn by

Dwg. of 45

SOC X-1

556-20-019

FINAL SOC 1/29/2021

vhanchjuhld Text Box Building 133

BUSINESS OCCUPANCY

BUILDING 133

BUILDING 133CA

BUSINESS OCCUPANCY

BUSINESS OCCUPANCY

BUILDING 133

BUILDING 133CA

BUSINESS OCCUPANCY

HE

HE

HE

EX

HE

EX

BUSINESS OCCUPANCY

BUILDING 133EF

BUILDING 133

BUSINESS OCCUPANCY

BUSINESS OCCUPANCY

BUILDING 133EF

BUILDING 133

BUSINESS OCCUPANCY

F

AED

F

F

F

FACP

F

EX

HE

F

AED

F

F

F

F

F

F

F

FF

F

HE HE

F A

C P

UNDER

RENOVATION

BUILDING 133 BASEMENT

N

BUSINESS OCCUPANCY

FULLY SPRINKLERED

BASEMENT FLOOR

BUILDING 133

1786.32

DATEREVISIONS: NUMBER

DRAFT SOC 11/06/2020

FP&C Project Number Project NumberProject Title

Location

Issue Date

Drawing NumberApproved: Project Director

Drawing Title

ENGINEERS

Building Number

SITE NAME/ADDRESS

CONSULTANTS, LLC.

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE

1/29/2021 AF KW

NORTH CHICAGO, ILLINOIS

JAMES A. LOVELL FHCC

STATEMENT OF CONDITIONS

DOCUMENTATIONJAMES A. LOVELL

FHCC

3001 Green Bay Road

North Chicago, IL 60064 Checked by Drawn by

Dwg. of 45

133SOC-B

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SYMBOLS LIST

HORIZONTAL EXIT

PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

EP

LC

TC

EX

HE

SPRINKLER AND FIRE ALARM ZONE BOUNDARY

NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)

EXIT STAIRWELL/PASSAGEWAY

APPROVED EQUIVALENCIES

1. OVERSIZED PROTECTIVE PLATES PERMITTED ON

FIRE RATED DOORS.

2. SELF-CLOSING DOOR REQUIREMENT FOR CORRIDOR

DOORS IN A DOMICILIARY OCCUPANCY.

3. BUSINESS OCCUPANCY DEAD END CORRIDORS

PERMITTED TO EXCEED 50' FEET.

APPROVED SITE SPECIFIC EQUIVALENCIES

1. BUILDINGS 66 AND 131 - SINGLE EXIT MECHANICAL

PENTHOUSES.

2. ALL BUILDINGS - EXISTING DEAD END CORRIDORS.

556-20-019

FINAL SOC 1/29/2021

EX

EX

EX

EX

BUILDING 133CA

BUSINESS OCCUPANCY

BUILDING 133

AMBULATORY HEALTH CARE

OCCUPANCY

BUILDING 133

AMBULATORY HEALTH CARE

OCCUPANCY

BUILDING 133CA

BUSINESS OCCUPANCY

UNDER

RENOVATION

OUTPATIENT

PHARMACY

EX

1D189

OUTPATIENT

PHARMACY

1A-115A

HE

HE

LC

BUILDING 133

AMBULATORY HEALTH

CARE OCCUPANCY

BUILDING 133EF

BUSINESS OCCUPANCY

BUILDING 133

AMBULATORY HEALTH

CARE OCCUPANCY

BUILDING 133EF

BUSINESS OCCUPANCY

F

F

F

F

F

AED

AED

F

F

F

F

EX

F

F

AED

F

SZ 133-1-A1

SZ 133-1-A2

SZ 133-1-B1

SZ 133-1-B2

F

A

A

B

EX

A

A

BUILDING 133 FIRST

N

AMBULATORY HEALTH CARE OCCUPANCY

FULLY SPRINKLERED

FIRST FLOOR

BUILDING 133

DRAWING KEYNOTES:

A

1786.32

DATEREVISIONS: NUMBER

DRAFT SOC 11/06/2020

FP&C Project Number Project NumberProject Title

Location

Issue Date

Drawing NumberApproved: Project Director

Drawing Title

ENGINEERS

Building Number

SITE NAME/ADDRESS

CONSULTANTS, LLC.

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE

1/29/2021 AF KW

NORTH CHICAGO, ILLINOIS

JAMES A. LOVELL FHCC

STATEMENT OF CONDITIONS

DOCUMENTATIONJAMES A. LOVELL

FHCC

3001 Green Bay Road

North Chicago, IL 60064 Checked by Drawn by

Dwg. of 45

133SOC-1

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SYMBOLS LIST

HORIZONTAL EXIT

PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

EP

LC

TC

EX

HE

SPRINKLER AND FIRE ALARM ZONE BOUNDARY

NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)

EXIT STAIRWELL/PASSAGEWAY

APPROVED EQUIVALENCIES

1. OVERSIZED PROTECTIVE PLATES PERMITTED ON

FIRE RATED DOORS.

2. SELF-CLOSING DOOR REQUIREMENT FOR CORRIDOR

DOORS IN A DOMICILIARY OCCUPANCY.

3. BUSINESS OCCUPANCY DEAD END CORRIDORS

PERMITTED TO EXCEED 50' FEET.

APPROVED SITE SPECIFIC EQUIVALENCIES

1. BUILDINGS 66 AND 131 - SINGLE EXIT MECHANICAL

PENTHOUSES.

2. ALL BUILDINGS - EXISTING DEAD END CORRIDORS.

556-20-019

FINAL SOC 1/29/2021

SUITE DESCRIPTIONS

SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER

B

SMOKE ZONE SQ. FT. OCCUPANCY

SMOKE ZONE SIZE

HEALTH CARE OCCUPANCY

BUILDING 133CA

HEALTH CARE OCCUPANCY

BUILDING 133

HEALTH CARE OCCUPANCY

BUILDING 133CA

AMBULATORY HEALTH CARE

OCCUPANCY

HE

HE

HE

LC

HEALTH CARE OCCUPANCY

BUILDING 133EF

BUILDING 133

BUSINESS OCCUPANCY

HEALTH CARE OCCUPANCY

BUILDING 133EF

BUILDING 133

BUSINESS OCCUPANCY

F

F

F

F

F

A E

D

F

A E

D

A E

D

F

F

F

F

SZ 133-2-A1

SZ 133-2-A2

SZ 133CA-2-D

SZ 133CA-2-C

SZ 133-2-A2 SZ 133-2-B

A

A

SZ 133-2-A2

SZ 133-2-C

UNDER

RENOVATION

SZ 133CA-2-A

A

B

BUILDING 133 SECOND

N

HEALTH CARE OCCUPANCY

FULLY SPRINKLERED

BUILDING 133

DRAWING KEYNOTES:

A

1786.32

DATEREVISIONS: NUMBER

DRAFT SOC 11/06/2020

FP&C Project Number Project NumberProject Title

Location

Issue Date

Drawing NumberApproved: Project Director

Drawing Title

ENGINEERS

Building Number

SITE NAME/ADDRESS

CONSULTANTS, LLC.

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE

1/29/2021 AF KW

NORTH CHICAGO, ILLINOIS

JAMES A. LOVELL FHCC

STATEMENT OF CONDITIONS

DOCUMENTATIONJAMES A. LOVELL

FHCC

3001 Green Bay Road

North Chicago, IL 60064 Checked by Drawn by

Dwg. of 45

133SOC-2

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SYMBOLS LIST

HORIZONTAL EXIT

PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

EP

LC

TC

EX

HE

SPRINKLER AND FIRE ALARM ZONE BOUNDARY

NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)

EXIT STAIRWELL/PASSAGEWAY

APPROVED EQUIVALENCIES

1. OVERSIZED PROTECTIVE PLATES PERMITTED ON

FIRE RATED DOORS.

2. SELF-CLOSING DOOR REQUIREMENT FOR CORRIDOR

DOORS IN A DOMICILIARY OCCUPANCY.

3. BUSINESS OCCUPANCY DEAD END CORRIDORS

PERMITTED TO EXCEED 50' FEET.

APPROVED SITE SPECIFIC EQUIVALENCIES

1. BUILDINGS 66 AND 131 - SINGLE EXIT MECHANICAL

PENTHOUSES.

2. ALL BUILDINGS - EXISTING DEAD END CORRIDORS.

556-20-019

FINAL SOC 1/29/2021

SECOND FLOOR

SUITE DESCRIPTIONS

SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER

BUSINESS OCCUPANCY

BUILDING 133CA

HEALTH CARE OCCUPANCY

BUSINESS OCCUPANCY

BUILDING 133

BUILDING 133CA

HEALTH CARE OCCUPANCY

1 2

HE

LC

HEALTH CARE OCCUPANCY

BUILDING 133EF

BUILDING 133

BUSINESS OCCUPANCY

HEALTH CARE OCCUPANCY

BUILDING 133EF

BUILDING 133

BUSINESS OCCUPANCY

F

F F

F

F

AED

AED

F

AED

F

AED

F

A

F F

F

SZ 133-3-A SZ 133-3-B

SZ 133-3-B SZ 133-3-C

A

UNDER

RENOVATION

BUILDING 133 THIRD

N

HEALTH CARE OCCUPANCY

FULLY SPRINKLERED

BUILDING 133

DRAWING KEYNOTES:

A

1786.32

DATEREVISIONS: NUMBER

DRAFT SOC 11/06/2020

FP&C Project Number Project NumberProject Title

Location

Issue Date

Drawing NumberApproved: Project Director

Drawing Title

ENGINEERS

Building Number

SITE NAME/ADDRESS

CONSULTANTS, LLC.

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE

1/29/2021 AF KW

NORTH CHICAGO, ILLINOIS

JAMES A. LOVELL FHCC

STATEMENT OF CONDITIONS

DOCUMENTATIONJAMES A. LOVELL

FHCC

3001 Green Bay Road

North Chicago, IL 60064 Checked by Drawn by

Dwg. of 45

133SOC-3

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SYMBOLS LIST

HORIZONTAL EXIT

PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

EP

LC

TC

EX

HE

SPRINKLER AND FIRE ALARM ZONE BOUNDARY

NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)

EXIT STAIRWELL/PASSAGEWAY

APPROVED EQUIVALENCIES

1. OVERSIZED PROTECTIVE PLATES PERMITTED ON

FIRE RATED DOORS.

2. SELF-CLOSING DOOR REQUIREMENT FOR CORRIDOR

DOORS IN A DOMICILIARY OCCUPANCY.

3. BUSINESS OCCUPANCY DEAD END CORRIDORS

PERMITTED TO EXCEED 50' FEET.

APPROVED SITE SPECIFIC EQUIVALENCIES

1. BUILDINGS 66 AND 131 - SINGLE EXIT MECHANICAL

PENTHOUSES.

2. ALL BUILDINGS - EXISTING DEAD END CORRIDORS.

556-20-019

FINAL SOC 1/29/2021

THIRD FLOOR

SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER

SUITE DESCRIPTIONS

STAIR

HALL

NO. 2

HOPTEL

ROOM

4A-144

4A-145

PATIENT

ROOM

BATH

4A-145A BATH

4A-146A

PATIENT

ROOM

4A-146

PATIENT

ROOM

4A-147

BATH

4A-147A

MED/

SURG

BEDROOM,

2 BED

4A-148

BATH

4A-148A

PHYS.

CHART.

4A-149

SUPP.

C4-111A

MEDS.

4A-151A

NOUR.

4A-150

NURSE

SUB

STATION

4A-151

CONF./

REPORT

4A-152

STORAGE

EQUIP.

4A-153

BATH

4A-155B

TOILET

STAFF

4A-154

HAC

4A-155A

PEDS

ISO

BEDROOM

NEG.

4A-155A

CR.

CRT.

C4-111C

SUPP.

C4-111B

CHART.

SAT.

C4-111D

BATH

4A-144A

BATH

4A-143A

PATIENT

ROOM

4A-143

PATIENT

ROOM

4A-142 BATH

4A-142A

BATH

4A-141A

CHART.

SAT.

C4-111E

CORRIDOR

C4-111

PATIENT

ROOM

4A-141

TEL

DATA

4A-140UTILITY

RM.

SOILED

4A-137

CLEAN

SUPPLY

4A-139

ELEC.

CLO.

4A-136

ANTERM.

NEG.

ISO

4A-135A

LIN.

RM.

CLEAN

4A-128

CHART.

SAT.

C4-106A

PATIENT

ROOM

4A-127

BATH

4A-127A

BATH

4A-130A

PATIENT

RM. ISO

NEG.

PRESS.

4A-135

BATH

4A-135B

PATIENT

ROOM

4A-130

BATH

4A-126A

PATIENT

ROOM

4A-131

BATH

4A-131A

C O

R R

ID

O

R C

4-

PATIENT

ROOM

4A-134

BATH

4A-134A

CHART.

SAT.

C4-110B

SUPP.

C4-110A

BATH

4A-132A

CHART

ROOM

4A-134B

PATIENT

ROOM

4A-132

STAIR

HALL

NO. 6

STORAGE

EQUIP.

4A-103

BREAK

RM.

STAFF

4A-104

TOILET

WMN

STAFF

4A-112

TOILET

MN

STAFF

4A-110

STAFF

LOCKER

RM.

4A-105

OFFICE

OTHER

4A-106

BREAK

RM.

RESIDENT4A-107

RESIDENCY

CONF./

CLASSRM.

4A-108

CUBICLE

DIET./

PHARM.

4A-109

OFFICE

PHYS.

4A-111

OFFICE

NURSE

SUP.

4A-113

C O

R R

ID

O

R C

4-

CORRIDOR

C4-104

STOR.

4A-108A

C O

R R

ID

O

R C

4-

LIN.

CHUTE

4A-114

PATIENT

ROOM

4A-126

PEDS

BEDROOM

4A-155C

TOILET

PUBLIC

- WMN

4A-117

TOILET

PUBLIC

-MN

4A-116

CUBICLE,

ADMIN.

4A-123,A,B & C

FAMILY

WAIT.

4A-124

BATH

4A-155D

DOCTORS

CHART

ROOM

4A-155

TOILET

STAFF

4A-102

HAC

4A-101

CONSULT.

4A-115

LIN.

RM.

CLEAN

4A-125A

PATIENT

ROOM

4A-122

PATIENT

ROOM

4A-119

ELEC.

4A-118

FEC.

ELEC.

4A-100

CORRIDOR

C4-106

ELEV.

LOBBY

C4-100

STAIR

HALL

NO.1

C O

R R

ID

O

R C

4-

CORRIDOR

C4-102

EXAM/TRTMNT.

4A-125

CHART.

SAT.

C4-107I

WHL

CHAIR

C4-107H

PATIENT

ROOM

4A-121

PATIENT

ROOM

4A-120

SUPP.

C4-107B

PATIENT

ROOM

4B-122 PATIENT

ROOM

4B-120

PATIENT

ROOM

4B-121

PATIENT

ROOM

4B-119

PATIENT

RM. ISO.

NEG.

PRESS.

4B-123

TOILET

STAFF

4B-118

ANTERM. -

NEG. ISO

4B-123A

HAC

4B-124

DATA &

TELE

4B-117

ELEC.

4B-116

CHART.

SAT.

C4-109B

SUPP.

C4-107A

BATH

4A-119A

PATIENT

ROOM

4B-106

BATH

4A-120A

BATH

4A-122A

BATH

4A-121A

NURSE

SUB

STATION

4B-101

CONF./

REPORT

4B-100

MEDS.

4B-101A

NOUR.

4B-102

BATH

4B-122A

BATH

4B-120A

BATH

4B-119A

BATH

4B-121A

BATH

4B-123B

SUPP

C4-109A

C O

R R

ID

O

R C

4-

C

O R

R

ID

O R

C 4-

PATIENT

ROOM

4B-108

CHART.

SAT.

C4-107F

PATIENT

ROOM

4B-109

PATIENT

ROOM

4B-107

SUPP.

C4-107E

CHART.

SAT.

C4-107G

PATIENT

ROOM

4B-105

PATIENT

ROOM

4B-104

LINEN

4B-103

UTILITY

RM.

SOILED

4B-113

CLEAN

SUPPLY

4B-115

PATIENT

ROOM

4B-111

PATIENT

ROOM

4B-110

SUPP.

C4-107C

BATH

4B-111A

BATH

4B-110A

BATH

4B-105A

BATH

4B-104A BATH

4B-106A

BATH

4B-107A

BATH

4B-109A

BATH

4B-108A

DATA

TEL.

4B-112

CR

CRT

C4-107D FEC

CORRIDOR

C4-107

STAIR

HALL

NO. 5

ROOF BELOWROOF BELOWROOF BELOW

HEALTH CARE OCCUPANCY

BUILDING 133EF

BUILDING 133

INDUSTRIAL OCCUPANCY

HEALTH CARE OCCUPANCY

BUILDING 133EF

BUILDING 133

INDUSTRIAL OCCUPANCY

F

F

F

AED

F

F

F

F

SZ 133-4-A SZ 133-4-B

SZ 133-4-B SZ 133-4-C

UNDER

RENOVATION

BUILDING 133 FOURTH

N

HEALTH CARE OCCUPANCY

FULLY SPRINKLERED

BUILDING 133 & 133CA

133 & 133CA

1786.32

DATEREVISIONS: NUMBER

DRAFT SOC 11/06/2020

FP&C Project Number Project NumberProject Title

Location

Issue Date

Drawing NumberApproved: Project Director

Drawing Title

ENGINEERS

Building Number

SITE NAME/ADDRESS

CONSULTANTS, LLC.

1520 MAIN STREET

INDIANAPOLIS, IN 46224

(317) 486-5188

FIRE PROTECTION & CODE

1/29/2021 AF KW

NORTH CHICAGO, ILLINOIS

JAMES A. LOVELL FHCC

STATEMENT OF CONDITIONS

DOCUMENTATIONJAMES A. LOVELL

FHCC

3001 Green Bay Road

North Chicago, IL 60064 Checked by Drawn by

Dwg. of 45

133SOC-4

AREA OPEN TO CORRIDOR WITH SMOKE DETECTION

AREA OPEN TO CORRIDOR NO SMOKE DETECTION REQUIRED

PARTITION LEGEND

2 HOUR FIRE BARRIER

2 HOUR FIRE/SMOKE ZONE BARRIER

SMOKE ZONE BARRIER

1 HOUR FIRE BARRIER (HAZARDOUS ROOM ENCLOSURE)

NON-RATED SMOKE ZONE PARTITION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

HEALTH CARE OCCUPANCY CORRIDORS

SUITE DESIGNATION

SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE

1 HOUR FIRE BARRIER HAZARDOUS ROOM ENCLOSURE

SYMBOLS LIST

HORIZONTAL EXIT

PASSAGEWAY

EXIT

EXIT PASSAGEWAY

LINEN CHUTE

TRASH CHUTE

EP

LC

TC

EX

HE

SPRINKLER AND FIRE ALARM ZONE BOUNDARY

NON-RATED SMOKE BARRIER (COMMUNICATING SPACE)

EXIT STAIRWELL/PASSAGEWAY

APPROVED EQUIVALENCIES

1. OVERSIZED PROTECTIVE PLATES PERMITTED ON

FIRE RATED DOORS.

2. SELF-CLOSING DOOR REQUIREMENT FOR CORRIDOR

DOORS IN A DOMICILIARY OCCUPANCY.

3. BUSINESS OCCUPANCY DEAD END CORRIDORS

PERMITTED TO EXCEED 50' FEET.

APPROVED SITE SPECIFIC EQUIVALENCIES

1. BUILDINGS 66 AND 131 - SINGLE EXIT MECHANICAL

PENTHOUSES.

2. ALL BUILDINGS - EXISTING DEAD END CORRIDORS.

556-20-019

FINAL SOC 1/29/2021

FOURTH FLOOR

SUITE NUMBER SUITE NAME SUITE SIZE TYPE OF SUITE EXIT NUMBER

SUITE DESCRIPTIONS

FHCC VA NORTH CHICAGO 1
FHCC VA NORTH CHICAGO 16
FHCC VA NORTH CHICAGO 20
FHCC VA NORTH CHICAGO 24
FHCC VA NORTH CHICAGO 28
FHCC VA NORTH CHICAGO 32

File details come from the government source that posted it. Updated .