S02_Attachment 8_842CM3027_FYNC_Drawings.pdf
PDF 12 MB Posted
- Attached to
- Y1PZ--Fayetteville National Cemetery, Columbaria and In-ground Cremains Burial Expansion (VA-25-00092710)
- Solicitation number
- 36C78626B0001
About this file
These are architectural and engineering design documents (bid documents) for the Fayetteville National Cemetery Columbarium and In-Ground Cremains Burial Expansion project located in Fayetteville, Arkansas. The project is under the jurisdiction of the U.S. Department of Veterans Affairs, Office of Design and Construction Service. The documents comprise 121 pages of detailed construction drawings and specifications covering structural foundation plans, fire alarm systems, plumbing, mechanical HVAC systems, electrical systems, and technology infrastructure.
The foundation plan drawings (sheets SS101, S-301, S-302) detail concrete spread footings, wall footings, stepped footing details, and construction joint specifications for the columbarium and retaining wall structures, with reinforcement schedules specifying rebar sizes and spacing. Fire alarm documents establish a complete fire alarm system with smoke detectors, manual pull stations, strobes, and speaker/light assemblies in compliance with NFPA 72, including specifications for plenum-rated cabling and UL-listed components. The plumbing scope includes a gas water heater (199 MBH), circulating pump, emergency shower/eyewash station, and fixture schedules. The mechanical systems specify an air handling unit (1,400 CFM), ductless split heat pump, unit heaters (75 MBH each), and ceiling exhaust fan. Electrical documents detail panelboard configurations, branch circuits, equipment schedules for HVAC components, and a fuel oil storage tank system with leak detection. The technology section includes structured cabling with CAT6A copper and multimode fiber optic backbone infrastructure, telecommunications equipment racks, and grounding specifications per TIA-607 standards. All work must comply with applicable codes including IBC, NEC, IMC, NFPA standards, and VA design guidelines.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5_8
8"
5_8
3/ S-302
S-301
_____________________ 2
S-302
WF1C.J. C.J. C.J.
(1241.54')
1' - 10"
28' - 8"
2' - 5 5/8"
28' - 8"
2' - 5 5/8"
28' - 8"
2' - 5 5/8"
28' - 8"
1' - 10"
7/
8"
2'
/8
7 11/16"7 11/16"
S-301
S-301
S-302
S-302
1 2
1 5
WF1
WF1
F1
WF2
W F
C.J. C.J. C.J. C.J.C.J. C.J. C.J.
(1233.84')
GRADE
BEAM
(1234.53')
1' - 10"
24' - 8"
2' - 5 5/8"
28' - 8"
2' - 5 5/8"
24' - 8"
1' - 10"
17' - 9 7/8"
1' - 10"
24' - 8"
2' - 5 5/8"
28' - 8"
2' - 5 5/8"
24' - 8"
1' - 10"
2'
/8
7/
8"
16' - 11 3/8"
8 3/4"
3/
4"
7 11/16"
1'
7 11/16"
1/ S-301 2/ S-301
A G
P ro je c t N o . Integrity Federal Services - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456 Dwg. ofRevisions: Date:
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
CB Design Group
(601) 278-0966
Above Group
(321) 345-9026
Aqua Engineering
(970) 372-6104
U.S. Department of Veterans Affairs
Office of Design and Construction
Service
COLUMBARIUM AND RETAINING WALL
FOUNDATION PLAN
BID DOCUMENTS
MAY 20, 2025 SLSRAS
SS101
74 121
FAYETTEVILLE, ARKANSAS
FAYETTEVILLE NATIONAL CEMETERY
COLUMBARIUM AND IN-GROUND
CREMAINS BURIAL EXPANSION
842CM3027
CODED NOTES:
SINGLE SIDED COLUMBARIUM UNITS AND MASONRY RETAINING WALL, REFER TO SECTIONS CUT ON
PLAN.
CONCRETE GRADE BEAM SPANNING OVER EXISTING STORM DRAIN PIPE. BOTTOM OF BEAM TO BE
1'-6" BELOW GRADE, REFER TO SECTION CUT ON PLAN.
EXISTING 36" DIA. STORM DRAIN PIPE, TOP OF PIPE ELEVATION IS APPROXIMATELY 1'-10" BELOW
GRADE.
CONCRETE RETAINING WALL WITH BRICK VENEER, REFER TO SECTION CUT ON PLAN.
CONCRETE PIER WITH BRICK VENEER, REFER TO DETAIL SIM.
DRAWING NOTES:
1. TOP OF FOOTING ELEVATIONS SHOWN ON PLAN THUS (.....).
2. STEP FOOTINGS PER DETAIL .
3. C.J. DENOTES CONTROL JOINT IN CONCRETE WALL, REFER TO DETAIL .
4. REFER TO CIVIL DRAWINGS FOR DIMENSIONS AND FURTHER DETAILS.
N
0 4' 8' 16' 24'
1/8" = 1'-0"
CONCRETE SPREAD FOOTING SCHEDULE
Mark Size Reinforcement
F1 4'-0"x4'-0"x1'-6" 5 #6 EACH WAY TOP & BOTTOM
CONCRETE WALL FOOTING SCHEDULE
Mark Size Reinforcement
WF1 5'-6"x1'-6" 6 #6 TOP & BOTTOM LONGITUDINAL, #6 AT 12" O.C. TRANSVERSE TOP & BOTTOM
WF2 4'-0"x1'-6" 5 #6 TOP & BOTTOMLONGITUDINAL, #6 AT 12" O.C. TRANSVERSE BOTTOM
1/8" = 1'-0"
COLUMBARIUM AND RETAINING WALL FOUNDATION PLAN NORTH
1/8" = 1'-0"
COLUMBARIUM AND RETAINING WALL FOUNDATION PLAN SOUTH
3" C
LE
A
R
3" CLEAR
7 11/16" 4' - 2 5/8" 7 11/16"
5' - 6"
4'
M A
X
2'
M
IN
CONCRETE WALL FOOTING,
REFER TO PLAN AND/OR
SCHEDULE
10 1/8" 1' - 3 3/16" 1' - 3 3/16" 10 1/8"
TOP OF PIER
VARIES, MATCH TOP OF ADJACENT PRECAST NICHE UNITS
TOP OF WALL FOUNDATION
VARIES, REFER TO CI DRAWINGS
EXTERIOR SIDEWALK,
REFER TO CIVIL DRAWINGS
ABOVE GRADE
1 1/2" CLEAR
3" CLEAR
FIELD DRILL HOLE IN CONCRETE TO ACCEPT
TYPE 304 SS 1/2" DIA. x 5" LONG PIN, (2) PER CAP
SET IN TYPE N MORTAR
TOP OF FOOTING
VARIES, REFER TO PLAN
TOP OF WALL SHELF
VARIES, REFER TO CI DRAWINGS
LIMESTONE BASE STONE,
REFER TO CI DRAWINGS
#6 AT 8" O.C.,
DOWEL INTO FOOTING
#6 AT 8" O.C.
CONCRETE PIER
CONCRETE PIER
VENEER TIE ANCHORS, BASIS OF DESIGN HOHMANN
& BARNARD TYPE 304 SS DW-10HS 14 GAUGE
ANCHOR, 3/16" DIA. TIE WITH (2) SIMPSON 1/4" DIA.
TYPE 410 SS TITEN CONCRETE SCREWS (1" MIN.
EMBED), REFER TO CI DRAWINGS FOR LOCATIONS
#5 AT 8" O.C.
#5 AT 8" O.C.
#5 AT 8" O.C. CONTINUED
FROM ADJACENT WALL
FOUNDATION, EXCEPT AT
C.J. REFER TO DETAIL
#5 AT 16" O.C.
CONTINUED FROM
ADJACENT WALL,
EXCEPT AT C.J.
REFER TO DETAIL
LIMESTONE CAP,
REFER TO CI DRAWINGS
BRICK VENEER,
REFER TO CI
DRAWINGS
NOTES:
REFER TO CI DRAWINGS FOR FURTHER DIMENSIONS AND DETAILS.
ALL STEEL TO BE STAINLESS 316.
1'
1" DEEP x 3" WIDE KEYWAY 2"
C
LE
A R
2" C
LE
A
R
3" CLEAR BELOW GRADE
2" C
LE
A
R
PRECAST COLUMBARIUM UNIT, REFER TO CI
DRAWINGS FOR UNITS AND EMBEDS
3" C
LE
A
R
3" CLEAR
1' - 1 3/16" 2' - 11" 1' - 5 13/16"
5' - 6"
4'
M A
X
2'
M
IN
#5 AT 8" O.C.,
DOWEL INTO FOOTING
#5 AT 8" O.C.
LIMESTONE CAP,
REFER TO CI DRAWINGS
CONCRETE WALL FOOTING,
REFER TO PLAN AND/OR
SCHEDULE
CONCRETE PIER
#5 AT 16" O.C.
#5 AT 16" O.C.
BRICK VENEER,
REFER TO CI
DRAWINGS
4 5/8" 9 7/8" 5 5/16" 1' - 3 3/16"
TOP OF WALL
VARIES, MATCH TOP OF ADJACENT PRECAST NICHE UNITS
TOP OF WALL FOUNDATION
VARIES, REFER TO CI DRAWINGS
CONCRETE PIER
EXTERIOR SIDEWALK,
REFER TO CIVIL DRAWINGS
ABOVE GRADE
1 1/2" CLEAR
VENEER TIE ANCHORS, BASIS OF DESIGN HOHMANN
& BARNARD TYPE 304 SS DW-10HS 14 GAUGE
ANCHOR, 3/16" DIA. TIE WITH (2) SIMPSON 1/4" DIA.
TYPE 410 SS TITEN CONCRETE SCREWS (1" MIN.
EMBED), REFER TO CI DRAWINGS FOR LOCATIONS
TOP OF FOOTING
VARIES, REFER TO PLAN
TOP OF WALL SHELF
VARIES, REFER TO CI DRAWINGS
FIELD DRILL HOLE IN CONCRETE TO ACCEPT
TYPE 304 SS 1/2" DIA. x 6" LONG PIN, (2) PER UNIT, PATCH WITH MORTAR
6"x12"x1/4" THICK SS EMBED PLATE, ATTACH TO CONCRETE WITH (2) 1/2" DIA. x 4" LONG HEADED
SS STUDS, SPACED 4" O.C. MIN. AND LOCATED
4" MIN. FROM EDGE OF CONCRETE,
REFER TO CI DRAWINGS FOR LOCATIONS 3/16"
TYP.
3"x1/4" THICK SS WELD PLATE, REFER TO CI DRAWINGS FOR LOCATIONS AND LENGTH
6"
2"
1/ 2"
NOTES:
REFER TO CI DRAWINGS FOR FURTHER DIMENSIONS AND DETAILS.
ALL STEEL TO BE STAINLESS 316.
#5 CONT.
1'
" 2"
C
LE
A R
3" CLEAR BELOW GRADE
2" C
LE
A
R
1" DEEP x 3" WIDE KEYWAY
REINFORCING TO MATCH FOOTING
REINFORCEMENT PER SCHEDULE
1' - 0"
2 "S" MINIMUM
"S
P E
R P
LA
N
S A
N D
/O R
S E
C T
IO
N
S F
O O
T
IN
G T
H
IC
K N
E S
S
NOTES:
1. STEP HEIGHT, "S" TO BE 2'-0" MAXIMUM.
2. WALL NOT SHOWN FOR CLARITY.
PREVIOUS POUR NEW POUR
FOOTING REINFORCEMENT, REFER
TO PLAN AND/OR SCHEDULE
EQ EQ
3/4" DIA.x2'-0" LONG EPOXY COATED SMOOTH DOWELS
AT 12" O.C. CENTERED IN WALL. LUBRICATE END OF
DOWEL OR WRAP IN BUILDING PAPER IN PREVIOUS
POUR.
CONCRETE
FOOTING
EXPANSION JOINT MATERIAL,
REFER TO SPECIFICATIONS
PREVIOUS POUR NEW POUR
WALL REINFORCEMENT, REFER TO
SECTION CUT ON PLAN
WALL REINFORCEMENT, REFER TO
SECTION CUT ON PLAN
EQ EQ
3/4" DIA.x2'-0" LONG EPOXY COATED SMOOTH DOWELS
AT 12" O.C. CENTERED IN WALL. LUBRICATE END OF
DOWEL OR WRAP IN BUILDING PAPER IN PREVIOUS
POUR.
CONCRETE PIER EXPANSION JOINT MATERIAL,
REFER TO SPECIFICATIONS
2/ S-301
2/ S-301
A G
P ro je c t N o . Integrity Federal Services - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456 Dwg. ofRevisions: Date:
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
CB Design Group
(601) 278-0966
Above Group
(321) 345-9026
Aqua Engineering
(970) 372-6104
U.S. Department of Veterans Affairs
Office of Design and Construction
Service
COLUMBARIUM AND RETAINING WALL
DETAILS AND SECTIONS 1
BID DOCUMENTS
MAY 20, 2025 SLSRAS
S-301
75 121
FAYETTEVILLE, ARKANSAS
FAYETTEVILLE NATIONAL CEMETERY
COLUMBARIUM AND IN-GROUND
CREMAINS BURIAL EXPANSION
842CM3027
1" = 1'-0"
COLUMBARIUM PIER SECTION
1" = 1'-0"
SINGLE SIDED COLUMBARIUM WALL SECTION
N.T.S.
STEPPED FOOTING DETAIL
N.T.S.
CONCRETE FOOTING CONSTRUCTION JOINT DETAIL
N.T.S.
CONCRETE WALL CONSTRUCTION JOINT DETAIL
1' - 6"
#4 TIES AT 12" O.C. MAX
CONCRETE GRADE BEAM
4 5/8" 8 3/4" 4 5/8"
TOP OF GRADE BEAM
REFER TO PLAN
NOTES:
REFER TO CI DRAWINGS FOR FURTHER DIMENSIONS AND DETAILS.
ALL STEEL TO BE STAINLESS 316.
(3) #6 TOP AND BOTTOM
CONTINUOUS
EXTERIOR SIDEWALK,
REFER TO CIVIL DRAWINGS
TOP OF WALL
REFER TO CI DRAWINGS
ON ALL SIDES
3" CLEAR TO TIES
EXISTING 36" DIA. STORM PIPE
3" CLEAR BELOW GRADE
3'
M A
X
/2
#5 AT 12" O.C.,
DOWEL INTO GRADE BEAM
#4 AT 12" O.C.
#5 AT 12" O.C.
FIELD DRILL HOLE IN CONCRETE TO ACCEPT
TYPE 304 SS 1/2" DIA. x 5" LONG PIN, (2) PER CAP
LIMESTONE CAP,
REFER TO CI DRAWINGS
BRICK VENEER,
REFER TO CI
DRAWINGS
VENEER TIE ANCHORS, BASIS OF DESIGN
HOHMANN & BARNARD TYPE 304 SS
DW-10HS 14 GAUGE ANCHOR, 3/16" DIA. TIE
WITH (2) SIMPSON 1/4" DIA. TYPE 410 SS
TITEN CONCRETE SCREWS (1" MIN. EMBED),
REFER TO CI DRAWINGS FOR LOCATIONS
ORNAMENT FENCE POST
SUPPORT, REFER TO DETAIL
CONCRETE WALL
ABOVE GRADE
1 1/2" CLEAR
TOP OF WALL SHELF
REFER TO CI DRAWINGS
TOP OF WALL SHELF
REFER TO CI DRAWINGS
TOP OF FOOTING
REFER TO PLAN
NOTES:
REFER TO CI DRAWINGS FOR FURTHER DIMENSIONS AND DETAILS.
ALL STEEL TO BE STAINLESS 316.
EXTERIOR SIDEWALK,
REFER TO CIVIL DRAWINGS
TOP OF WALL
REFER TO CI DRAWINGS
3" CLEAR BELOW GRADE
#5 AT 12" O.C.
#5 AT 12" O.C.
FIELD DRILL HOLE IN CONCRETE TO ACCEPT
TYPE 304 SS 1/2" DIA. x 5" LONG PIN, (2) PER CAP
LIMESTONE CAP,
REFER TO CI DRAWINGS
VENEER TIE ANCHORS, BASIS OF DESIGN
HOHMANN & BARNARD TYPE 304 SS
DW-10HS 14 GAUGE ANCHOR, 3/16" DIA. TIE
WITH (2) SIMPSON 1/4" DIA. TYPE 410 SS
TITEN CONCRETE SCREWS (1" MIN. EMBED),
REFER TO CI DRAWINGS FOR LOCATIONS
TOP OF WALL SHELF
VARIES, REFER TO CI DRAWINGS
3" C
LE
A
R
3" CLEAR 4 5/8" 8 3/4" 4 5/8"
4' - 0"
4'
M A
X
2'
M
IN
CONCRETE WALL FOOTING,
REFER TO PLAN AND/OR
SCHEDULE
1' - 1 1/4" 1' - 6" 1' - 4 7/8"
TOP OF WALL SHELF
VARIES, REFER TO CI DRAWINGS
ABOVE GRADE
1 1/2" CLEAR
#5 AT 12" O.C.
CONCRETE PIER
#5 AT 12" O.C.,
DOWEL INTO FOOTING
ORNAMENT FENCE POST
SUPPORT, REFER TO DETAIL
BRICK VENEER,
REFER TO CI
DRAWINGS
CONCRETE WALL
1'
" 1" DEEP x 3" WIDE KEYWAY2"
C
LE
A R
2" C
LE
A
R
2" C
LE
A
R
3" C
LE
A
R
3" CLEAR
11 11/16" 2' - 0 5/8" 11 11/16"
4' - 0"
2'
M
IN
#4 TIES AT 12" O.C.
CONCRETE FOOTING, REFER
TO PLAN AND/OR SCHEDULE
CONCRETE PIER
2' - 0 5/8"
TOP OF FOUNDATION
VARIES, REFER TO CI DRAWINGS
(8) #6 DOWELS
EXTERIOR SIDEWALK,
REFER TO CIVIL DRAWINGS
3" CLEAR TO TIES
TOP OF PIER
REFER TO CI DRAWINGS
LIMESTONE CAP,
REFER TO CI DRAWINGS
BRICK VENEER,
REFER TO CI
DRAWINGS
8"x8" CMU PIER, GROUTED SOLID WITH
TYPE S MORTAR
VENEER TIE ANCHORS, BASIS OF DESIGN HOHMANN
& BARNARD TYPE 304 SS DW-10HS 14 GAUGE
ANCHOR, 3/16" DIA. TIE WITH (2) SIMPSON 1/4" DIA.
TYPE 410 SS TITEN CONCRETE SCREWS (1" MIN.
EMBED), REFER TO CI DRAWINGS FOR LOCATIONS
#5 CENTERED
IN CMU
NOTES:
REFER TO CI DRAWINGS FOR FURTHER DIMENSIONS AND DETAILS.
ALL STEEL TO BE STAINLESS 316.
1'
" 1" DEEP x 3" WIDE KEYWAY
3/16"
CONCRETE WALL, REFER
TO SECTION CUT ON PLAN
ORNAMENTAL
ALUMINUM
RAILING, REFER
TO CI DRAWINGS
9 3/4" HSS2 1/2"x2 1/2"x1/4"
(3) 5/16" DIA.
CARRIAGE BOLTS
WITH TRI GROOVE
SECURITY NUTS
9"x4"x3/8" PLATE WITH (2) 1/2" DIA. x 4" LONG HEADED
STUDS
1/
2"
6"
1/
2"
3/16"
HSS3"x3"x1/4" x 6" LONG
NOTE: ALL STEEL TO BE SS304 AND POWDER COATED TO MATCH FENCE, U.N.O.
SECTION
1 1/2" 1 1/2"
3" 3"
4/ S-302 4/ S-302
A G
P ro je c t N o . Integrity Federal Services - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456 Dwg. ofRevisions: Date:
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
CB Design Group
(601) 278-0966
Above Group
(321) 345-9026
Aqua Engineering
(970) 372-6104
U.S. Department of Veterans Affairs
Office of Design and Construction
Service
COLUMBARIUM AND RETAINING WALL
DETAILS AND SECTIONS 2
BID DOCUMENTS
MAY 20, 2025 SLSRAS
S-302
76 121
FAYETTEVILLE, ARKANSAS
FAYETTEVILLE NATIONAL CEMETERY
COLUMBARIUM AND IN-GROUND
CREMAINS BURIAL EXPANSION
842CM3027
1" = 1'-0"
GRADE BEAM SECTION
1" = 1'-0"
RETAINING WALL SECTION
1" = 1'-0"
ORNAMENTAL FENCE PIER SECTION
N.T.S.
RAILING ATTACHMENT TO CONCRETE WALL DETAIL
FIRE ALARM ABBREVIATIONS
1PH SINGLE-PHASE
1P SINGLE POLE
2/C TWO-CONDUCTOR
3/C THREE-CONDUCTOR
3PH THREE-PHASE
4/C FOUR-CONDUCTOR
4W FOUR-WIRE
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AAP ALARM ANNUNCIATOR PANEL
AC ALTERNATING CURRENT OR ARMORED CABLE
ACC ACCESSIBLE
ADDL ADDITIONAL
ADJ ADJACENT, ADJOINING
ADO AUTOMATIC DOOR OPENER
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING JURISDICTION
ALT ALTERNATE
AMB OR A AMBIENT
ARCH ARCHITECT
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AV AUDIO VISUAL
BAT BATTERY
BC BARE COPPER
BD BOARD
BFF BELOW FINISH FLOOR
BLDG BUILDING
BPIP BOILER PLANT INSTRUMENTATION PANEL
BYP BY PASS
C CONDUIT
CAB CABINET
CALC CALCULATE
CAP CAPACITY
CAT CATALOG
CATV COMMUNITY ANTENNA TELEVISION
CCR CONTROL CONTACTOR
CCTV CLOSED CIRCUIT TELEVISION
CD CONSTRUCTION DOCUMENTS
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED
CF/OI CONTRACTOR FURNISHED/OWNER INSTALLED
CFE CONTRACTOR FURNISHED EQUIPMENT
CLG CEILING
CMU CONCRETE MASONRY UNIT
COAX COAX CABLE
COMM COMMUNICATION
COMPT COMPARTMENT
CONC CONCRETE
CONT CONTINUE
CONTR CONTRACTOR
COORD COORDINATE
CTV CABLE TELEVISION
CU COPPER
CU FT CUBIC FEET
CUR CURRENT
OC ON CENTER
OD OUTSIDE DIAMETER
P POLE
PA PUBLIC ADDRESS
PB PANELBOARD, PULL BOX, OR PUSHBUTTON
PBPU PREFABRICATED BEDSIDE PATIENT UNIT
PED PEDESTAL
PEND PENDANT
PF POWER FACTOR
PH PHASE
PNL PANEL
PVC POLYVINYL CHLORIDE (PLASTIC)
PWR POWER
RCP REFLECTED CEILING PLAN
REC RECESSED
RECPT RECEPTACLE
RGS RIGID GALVANIZED STEEL
RM ROOM
REQD REQUIRED
SF SQUARE FOOT (FEET)
SHT SHEET
SI INTERNATIONAL SYSTEM OF UNITS
SPEC SPECIFICATION
SURF SURFACE
SW SWITCH
TEL TELEPHONE
TP TWISTED PAIR
TPS TWISTED PAIR SHIELDED
TTB TELEPHONE TERMINAL BOARD
TV TELEVISION
TYP TYPICAL
UFD UNDERFLOOR DUCT
UGND UNDERGROUND
UL UNDERWRITERS LABORATORY
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
UTIL UTILITY
V VOLT
WP WEATHERPROOF
DB DECIBEL OR DIRECT BURIAL
DC DIRECT CURRENT
DEG C DEGREES CELSIUS
DEG F DEGREES FAHRENHEIT
DEMO DEMOLITION
DIAG DIAGRAM
DISTR DISTRIBUTION
DN DOWN
DRSW DOOR SWITCH
DWG DRAWING
EC EMPTY CONDUIT
EG EQUIPMENT GROUND
EL ELEVATION
ELEC ELECTRIC OR ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
EMI ELECTROMAGNETIC INTERFERENCE
EMT ELECTRICAL METALLIC TUBING
ENCL ENCLOSURE
EPO EMERGENCY POWER OFF
ESMT EASEMENT
EXIST EXISTING
FLEX FLEXIBLE METALLIC CONDUIT
FOUTT TELEPHONE FLOOR OUTLET
FP FIRE PROTECTION
FT FEET OR FOOT
FU SW FUSED SWITCH
G OR GND GROUND OR GENERATOR
GEN GENERATOR
GTB GROUND TERMINAL BOX
HOA HAND-OFF-AUTOMATIC
HT HEIGHT
HZ HERTZ
IMC INTERMEDIATE METAL CONDUIT
IR INFRARED
J-BOX JUNCTION BOX
LF LINEAR FEET (FOOT)
LTNG LIGHTING
LV LOW VOLTAGE
MATV MASTER ANTENNA TELEVISION SYSTEM
MAX MAXIMUM
MECH MECHANICAL
MH MANHOLE
MIN MINIMUM
MT MOUNT
MTD MOUNTED
MTG MOUNTING
NA NOT APPLICABLE
NEC NATIONAL ELECTRICAL CODE
NEUT OR N NEUTRAL
NIC NOT IN CONTRACT
NS NO SCALE
NTS NOT TO SCALE
ABBR. DESCRIPTION ABBR. DESCRIPTION ABBR. DESCRIPTION
FA1. ALL FIRE ALARM EQUIPMENT IS TO BE NEW.
FA2. ALL WIRING AND CONDUIT IS TO CONFORM TO NEC ARTICLE 760. WIRING
SHALL BE UL LISTED, MINIMUM 300V TYPE FPLP PLENUM RATED SOLID
COPPER OR STANDARD COPPER WITH MAXIMUM 19 STRANDS.
FA3. LOW VOLTAGE CONDUCTORS: PROVIDE CONDUCTORS IN ACCORDANCE WITH
NFPA 70 AND NFPA 72, AND AS RECOMMENDED BY THE FIRE ALARM SYSTEM
MANUFACTURER. CONDUCTORS SHALL BE COPPER, MINIMUM NO. 14 AWG,
TWISTED SHIELDED PAIR.
FA4. SURVIVABILITY: PER AUTHORITY HAVING JURISDICTION, WIRING INSTALLED IN
METAL RACEWAY WITHIN BUILDINGS THAT ARE PROTECTED THROUGHOUT BY
SPRINKLERS SHALL BE CONSIDERED TO MEET THE REQUIREMENTS FOR
PATHWAY SURVIVABILITY LEVEL 2 IN ACCORDANCE WITH NFPA 72 (2025) AS A
2-HOUR PERFORMANCE ALTERNATIVE.
FA5. PROVIDE FIRE ALARM RELAY AND DUCT DETECTOR CONNECTED TO FIRE
ALARM SYSTEM, WITHIN 5' OF ALL DUCT PENETRATIONS THROUGH
FIRE/SMOKE WALLS, WHETHER INDICATED ON ELECTRICAL OR MECHANICAL
PLANS OR NOT.
FA6. ALL FIRE ALARM POWER CIRCUITS SHALL HAVE A DEDICATED 120V 20A
BREAKER THAT SHALL BE RED IN COLOR AND MECHANICALLY PROTECTED
(LOCKABLE IN THE "ON" POSITION), MARKED AS "FIRE ALARM CIRCUIT".
FA7. MINIMUM CANDELA RATING OF STROBES IS 15CD UNLESS NOTED OTHERWISE;
"##" ADJACENT TO DEVICE INDICATES THE CANDELA RATING. PROVIDE
SYNCHRONIZATION OF STROBES IN ALL ADJACENT AREAS WHERE STROBES
ARE VISIBLE TO EACH OTHER.
FA8. FIRE ALARM DESIGN IS IN ACCORDANCE WITH THE NATIONAL FIRE
PROTECTION ASSOCIATION (NFPA 72 - 2025) AND NATIONAL FIRE CODES (NFC).
WHERE A FIRE ALARM RISER IS INDICATED, IT IS DIAGRAMMATIC IN NATURE
AND NOT INTENDED TO REPRESENT A COMPLETE WIRING AND DEVICE
DISPLAY. ALL WIRING AND DEVICES SHALL BE IN ACCORDANCE WITH
SELECTED VENDOR'S POINT-BY-POINT WIRING DIAGRAM. REFER TO FLOOR
PLAN FOR DESIGN INTENT AND PROPOSED QUANTITY OF FIRE ALARM SYSTEM
COMPONENTS.
FA9. THESE DRAWINGS ARE SCHEMATIC IN NATURE AND ARE NOT INTENDED TO
SHOW ALL POSSIBLE CONDITIONS. IT IS INTENDED THAT A COMPLETE FIRE
ALARM SYSTEM BE PROVIDED WITH ALL THE NECESSARY EQUIPMENT,
WIRING, CONDUIT, AND CONTROLS, COMPLETELY COORDINATED WITH ALL
DISCIPLINES. ANY ITEMS AND LABOR REQUIRED FOR A COMPLETE FIRE
ALARM SYSTEM, IN ACCORDANCE WITH ALL APPLICABLE CODES, STANDARDS,
LOCAL AUTHORITIES AND THESE CONTRACT DOCUMENTS SHALL BE
FURNISHED AT NO ADDITIONAL COST TO THE OWNER. THE FIRE ALARM
CONTRACTOR SHALL CAREFULLY REVIEW ALL CONTRACT DOCUMENTS AND
THE DESIGN OF OTHER TRADES BEFORE PREPARING SHOP DRAWINGS.
FA10. FIRE ALARM CONTRACTOR SHALL BE AWARE OF THE TYPE OF FINISHES,
DECOR AND OCCUPANCY. COORDINATION WITH THE STAKEHOLDERS(S)
SHALL BE PERFORMED BY THE FIRE ALARM CONTRACTOR FOR PLACEMENT
OF FIRE ALARM DEVICES.
FA11. FIRE ALARM SYSTEM SHALL COMPLY WITH NFPA 70 AND 72 FOR PROPER
INSTALLATION PRACTICES.
FA12. FIRE ALARM PATHWAYS IN ALL AREAS SHALL BE IN 3/4" EMT, AND SHALL BE
PAINTED RED. ALL FIRE ALARM WIRING SHALL BE ROUTED THROUGH CONDUIT
THAT IS STRICTLY DEDICATED FOR FIRE ALARM. NO OTHER SYSTEMS MAY
UTILIZE FIRE ALARM WIRING CONDUIT OR EMT.
FA13. ALL FIRE ALARM JUNCTION BOX AND PULL BOX COVERS SHALL BE PAINTED
RED.
FA14. PERFORM RE-ACCEPTANCE TESTING IN ACCORDANCE WITH NFPA 72.
FA15. FIRE ALARM CIRCUITS SHALL NOT HAVE SPLICES. CIRCUITS SHALL BE
EXTENDED FROM DEVICE AND APPLIANCE SCREW TERMINALS.
FIRE ALARM SYSTEM NOTESELECTRONIC SAFETY AND SECURITY SYMBOLS
SYMBOL DESCRIPTION
ALARM, FIRE, PANEL; LETTERS INDICATE AS FOLLOWS:
FACP = CONTROL PANEL
FAAP = FIRE ALARM ANNUNCIATER PANEL
ALARM, SPEAKER/LIGHT, ONE ASSEMBLY. ADJUSTABLE
15CD, 30CD, 75CD UNLESS OTHERWISE NOTED
ALARM, SPEAKER/LIGHT, SEPARATE ASSEMBLY. ADJUSTABLE
15CD, 30CD, 75CD UNLESS OTHERWISE NOTED
ALARM, LAMP LIGHT, SIGNAL LIGHT, STROBE. ADJUSTABLE
15CD, 30CD, 75CD UNLESS OTHERWISE NOTED
DETECTOR, HEAT
FIRE ALARM STATION, MANUAL PULL
FACP
HD
P
DETECTOR, SMOKESD
FIRE PROTECTION SPRINKLER ACTIVATION HORN.
1'-0" MAX.
FINISHED
FLOOR
SPEAKER
DEVICE
7'-6" TO TOP
OF DEVICE,
OR
0'-6" BELOW
FINISHED CEILING,
WHICHEVER IS
LOWER
6'-8" MIN. TO 8'-0" MAX.
FROM STROB LENS TO
FLOOR, OR
WITHIN 0'-6" OF
FINISHED CEILING,
WHICHEVER IS
LOWER
STROBE
DEVICE
SPEAKER/STROBE
COMBINATION
DEVICE
FIRE ALARM CONTROL
PANEL OR EMERGENCY
VOICE PANEL
ANNUNCIATOR
PANEL OR
TERMINAL
CABINET
MANUAL PULL
STATION
5'-6"
3'-10" FROM
OPERATING
HANDLE
TO FLOOR
5'-0" MAX.
FROM EXIT OPENING
0'-4" MIN. 3'-0" MIN.
SMOKE/HEAT
DETECTOR
MOUNT DETECTOR
ON APPROVED BOX 6'-0" MAX. LENGTH FLEXIBLE RACEWAY TO DEVICE MOUNTED
ON SUSPENDED CEILING
AIR SUPPLY DIFFUSER OR
RETURN AIR OPENING
JUNCTION BOX
CONDUIT
INSTALL PER NATIONAL
ELECTRIC CODE
FLOOR-CEILING
ASSEMBLY
SUSPENDED
CEILING
SMOKE
DETECTOR
1'-0" MAX.
FINISHED
FLOOR
SUSPENDED
CEILING
HEAT
DETECTOR
0'-4" MIN.
0'-4" MIN
HEAT
DETECTOR
DO NOT LOCATE
DETECTOR WITHIN
THIS AREA
HEAT DETECTOR MOUNTING
PLACEMENT REQUIREMENTS
NOTE: MOUNT FIRE ALARM DEVICES ON APPROVED BOXES.
MANUAL PULL STATION
SMOKE DETECTOR - SPOT TYPE
SHUNT TRIP POWER MONITOR
REMOTE POWER SUPPLY TROUBLE
AC POWER FAILURE
LOW BATTERY
ANY OPEN CIRCUIT
ANY GROUND FAULT
ANY NOTIFICATION APPLIANCE CIRCUIT SHORT
ANY TROUBLE
INPUTS
A C
T
IV
A T
E S
T R
O B
E S
T H
R O
U G
H O
U T
B U
IL
D
IN
G
D
IS
P
LA
Y A
LA
R
M C
O N
D
IT
IO
N
A T
F
IR
E A
LA
R
M C
O N
T R
O L
P A
N E
L
D
IS
P
LA
Y S
U P
E R
V
IS
O R
Y C
O N
D
IT
IO
N
A T
F
IR
E A
LA
R
M C
O N
T R
O L
P A
N E
L
D
IS
P
LA
Y T
R O
U B
LE
C
O N
D
IT
IO
N
A T
F
IR
E A
LA
R
M C
O N
T R
O L
P A
N E
L
D
IS
P
LA
Y T
R O
U B
LE
C
O N
D
IT
IO
N
A T
F
IR
E A
LA
R
M A
N N
U N
C
IA
T O
R P
A N
E L
T R
A N
S M
IT
C
O N
T A
C T
ID
T
O S
U P
E R
V
IS
IN
G
S T
A T
IO
N
OUTPUTS
NOTIFICATION
D E
-A C
T
IV
A T
E S
O U
N D
E R
B A
S E
A C
T
IV
A T
E S
O U
N D
E R
B A
S E
A B C D E F H I
INTERFACE
X X
X X
X
X
X X
XXX
XXX
XXX
XXX
XXX
XXX
XXX
X
X
FIRE ALARM CONTROL PANEL INTERFACE X
TYPICAL NEW FIRE
ALARM CONTROL PANEL
(FACP)
FIRST FLOOR
P
INDICATING DEVICES
TYPICAL INITIATION DEVICES
CEILING
SD
COMMUNICATION
TO LOCAL FIRE
DEPARTMENT
A G
P ro je c t N o . Integrity Federal Services - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456 Dwg. ofRevisions: Date:
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
CB Design Group
(601) 278-0966
Above Group
(321) 345-9026
Aqua Engineering
(970) 372-6104
U.S. Department of Veterans Affairs
Office of Design and Construction
Service
FIRE ALARM LEGENDS & SYMBOLS
(CLIN 2 - BID OPT 1)
BID DOCUMENTS
MAY 20, 2025 CVMJPH
FA001
77 121
FAYETTEVILLE, ARKANSAS
FAYETTEVILLE NATIONAL CEMETERY
COLUMBARIUM AND IN-GROUND
CREMAINS BURIAL EXPANSION
842CM3027
SHEET LIST
SHEET NUMBER SHEET NAME
FA001 FIRE ALARM LEGENDS & SYMBOLS (CLIN 2 - BID OPT 1)
FA101 SERVICE BUILDING PLAN - FIRE ALARM - DEMOLITION AND NEW WORK (CLIN
2 - BID OPT 1)
FA102 ADMIN BUILDING PLAN - FIRE ALARM - DEMOLITION AND NEW WORK (CLIN 2 -
BID OPT 1)
N.T.S.
FIRE ALARM DEVICE MOUNTING DETAIL
1 N.T.S3
TYPICAL FIRE ALARM MATRIX
N.T.S2
TYPICAL FIRE ALARM RISER DIAGRAM
P
SD
SD
SD
SD
SDSDSD
PP
SD
SD
SDSD
P
P
SD
SD
P
SD
OPEN WORK SPACE-1
A103-1
MEN'S LOCKER
A104
RESTROOM
A105
NEW TR
A101
NEW OFFICE
A114
EXISTING GARAGE
A102
FACP
30CD
15CD
15CD
15CD
15CD
30CD
15CD
15CD
15CD
OPEN WORK SPACE-1
A103-1
MEN'S LOCKER
A104
RESTROOM
A105
NEW TR
A101
NEW OFFICE
A114
EXISTING GARAGE
A102
D1
F A
C P
A G
P ro je c t N o . Integrity Federal Services - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456 Dwg. ofRevisions: Date:
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
CB Design Group
(601) 278-0966
Above Group
(321) 345-9026
Aqua Engineering
(970) 372-6104
U.S. Department of Veterans Affairs
Office of Design and Construction
Service
SERVICE BUILDING PLAN - FIRE
ALARM - DEMOLITION AND NEW
WORK (CLIN 2 - BID OPT 1)
BID DOCUMENTS
MAY 20, 2025 CVMJPH
FA101
78 121
FAYETTEVILLE, ARKANSAS
FAYETTEVILLE NATIONAL CEMETERY
COLUMBARIUM AND IN-GROUND
CREMAINS BURIAL EXPANSION
842CM3027
DEMOLITION CODED NOTES:
DRAWING NOTES:
1. CONTRACTOR TO VERIFY EXACT QUANTITIES AND LOCATIONS OF ALL DEVICES LOCATED WITHIN THE
AREA OF DEMOLITION AS INDICATED ON THIS DRAWING.
2. DRAWING IS DIAGRAMMATIC IN NATURE AND IS NOT TO BE CONSTRUED AS ALL INCLUSIVE; FIELD VERIFY EXISTING CONDITIONS AND ADJUST WORK AS REQUIRED TO EXECUTE SPECIFIED WORK.
3. CONTRACTOR TO FIELD VERIFY EXACT LOCATION AND QUANTITIES OF FIRE ALARM DEVICES PRIOR TO CONSTRUCTION. EXISTING CONDITIONS INDICATED ARE BASED ON GENERAL FIELD NOTES AND
HISTORICAL DATA AND DOCUMENTATION AND ARE FOR REFERENCE PURPOSES ONLY TO DEFINE
SCOPE OF WORK. CONTRACTOR TO DOCUMENT VARIANCES ON AS-BUILT DRAWINGS.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING CONDITIONS FROM DAMAGE
DURING CONSTRUCTION. ANY MATERIALS, SYSTEMS, COMPONENTS, FINISHES, ETC. THAT ARE
DAMAGED DURING CONSTRUCTION MUST BE REPAIRED OR REPLACED AT CONTRACTOR'S EXPENSE
TO THE APPROVAL OF THE VA.
5. FIRE ALARM WORK INCLUDES, BUT IS NOT LIMITED TO, REMOVAL OF EXISTING DEVICES AND ASSOCIATED EQUIPMENT BACK TO SOURCE, PROVIDING ALL MATERIALS, TOOLS, LABOR, TESTING
INSTRUMENTS, ETC. REQUIRED FOR THE COMPLETE REPLACEMENT WITH A FULLY FUNCTIONAL
SYSTEM.
6. PENETRATIONS IN FIRE RATED ASSEMBLIES RESULTING FROM THE REMOVAL OF EQUIPMENT, PATHWAYS, CABLING, OR OTHER EQUIPMENT SHALL BE FIRE STOPPED PER THE LATEST EDITION OF
THE UL FIRE RESISTANCE DIRECTORY.
7. INTERIOR FIRE WALL PENETRATIONS - CONTRACTOR SHALL PROVIDE APPROVED UL LISTED FIRE
RATED ASSEMBLY OR SYSTEM TO MAINTAIN FIRE RATING OF EXISTING FIRE BARRIER.
8. THE OWNER CLAIMS FIRST RIGHT OF REFUSAL FOR EXISTING EQUIPMENT. COORDINATE SALVAGE
REQUIREMENTS WITH THE OWNER PRIOR TO DEMOLITION. IDENTIFY, TAG, AND CAREFULLY
DECOMMISSION EQUIPMENT TO BE SALVAGED FOR THE OWNER. EQUIPMENT NOT WANTED BY THE
OWNER SHALL BE REMOVED FROM THE SITE AT THE CONTRACTOR'S EXPENSE.
DISCONNECT AND REMOVE EXISTING FIRE ALARM SYSTEM IN ITS ENTIRETY.D1
NN
0 4' 8' 16' 24'
1/8" = 1'-0"
1/8" = 1'-0"
SERVICE BUILDING PLAN - FIRE ALARM - NEW WORK
1/8" = 1'-0"
SERVICE BUILDING PLAN - FIRE ALARM - DEMOLITION
NEW CODED NOTES:
COORDINATE EXACT LOCATION OF FACP WITH EXISTING CONDITIONS PRIOR TO CONSTRUCTION.1
SD
SD
SD
SD
SDSD
SD
SD
P
P
OPERATIONAL CENTER/ LOUNGE
A113
MEN'S RESTROOM
A112
WOMEN'S RESTROOM
A111
FACP
GENERAL OFFICE/LOBBY
A103-3
CLOSET
A103-4
DIRECTOR OFFICE
A103-5
STORAGE
A103-6
MECHANICAL
A103-7
STAFF TOILET
A103-8
30CD 30CD
75CD
75CD
30CD
30CD
WP
WP
15CD
30CD
F A
A P
OPERATIONAL CENTER/ LOUNGE
A113
MEN'S RESTROOM
A112
WOMEN'S RESTROOM
A111
D1
FACP
F A
A P
A G
P ro je c t N o . Integrity Federal Services - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456 Dwg. ofRevisions: Date:
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
CB Design Group
(601) 278-0966
Above Group
(321) 345-9026
Aqua Engineering
(970) 372-6104
U.S. Department of Veterans Affairs
Office of Design and Construction
Service
ADMIN BUILDING PLAN - FIRE ALARM -
DEMOLITION AND NEW WORK (CLIN 2
- BID OPT 1)
BID DOCUMENTS
MAY 20, 2025 CVMJPH
FA102
79 121
FAYETTEVILLE, ARKANSAS
FAYETTEVILLE NATIONAL CEMETERY
COLUMBARIUM AND IN-GROUND
CREMAINS BURIAL EXPANSION
842CM3027
NN
0 4' 8' 16' 24'
1/8" = 1'-0"
1/8" = 1'-0"
ADMIN BUILDING PLAN - FIRE ALARM - NEW WORK
DEMOLITION CODED NOTES:
DRAWING NOTES:
1. CONTRACTOR TO VERIFY EXACT QUANTITIES AND LOCATIONS OF ALL DEVICES LOCATED WITHIN THE
AREA OF DEMOLITION AS INDICATED ON THIS DRAWING.
2. DRAWING IS DIAGRAMMATIC IN NATURE AND IS NOT TO BE CONSTRUED AS ALL INCLUSIVE; FIELD VERIFY EXISTING CONDITIONS AND ADJUST WORK AS REQUIRED TO EXECUTE SPECIFIED WORK.
3. CONTRACTOR TO FIELD VERIFY EXACT LOCATION AND QUANTITIES OF FIRE ALARM DEVICES PRIOR TO CONSTRUCTION. EXISTING CONDITIONS INDICATED ARE BASED ON GENERAL FIELD NOTES AND
HISTORICAL DATA AND DOCUMENTATION AND ARE FOR REFERENCE PURPOSES ONLY TO DEFINE
SCOPE OF WORK. CONTRACTOR TO DOCUMENT VARIANCES ON AS-BUILT DRAWINGS.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING CONDITIONS FROM DAMAGE
DURING CONSTRUCTION. ANY MATERIALS, SYSTEMS, COMPONENTS, FINISHES, ETC. THAT ARE
DAMAGED DURING CONSTRUCTION MUST BE REPAIRED OR REPLACED AT CONTRACTOR'S EXPENSE
TO THE APPROVAL OF THE VA.
5. THIS SITE IS AN ACTIVE WORKING ENVIRONMENT; SYSTEMS SHALL NOT BE SHUT DOWN WITHOUT
WRITTEN AUTHORIZATION; ALL REQUESTS SHALL BE SUBMITTED IN WRITING A MINIMUM OF
FOURTEEN (14) WORKING-DAYS PRIOR TO PROPOSED ACTIVITY DATE OR NEED UNLESS DIRECTED
OTHERWISE.
6. FIRE ALARM WORK INCLUDES, BUT IS NOT LIMITED TO, REMOVAL OF EXISTING DEVICES AND ASSOCIATED EQUIPMENT BACK TO SOURCE, PROVIDING ALL MATERIALS, TOOLS, LABOR, TESTING
INSTRUMENTS, ETC. REQUIRED FOR THE COMPLETE REPLACEMENT WITH A FULLY FUNCTIONAL
SYSTEM.
7. PENETRATIONS IN FIRE RATED ASSEMBLIES RESULTING FROM THE REMOVAL OF EQUIPMENT, PATHWAYS, CABLING, OR OTHER EQUIPMENT SHALL BE FIRE STOPPED PER THE LATEST EDITION OF
THE UL FIRE RESISTANCE DIRECTORY.
8. INTERIOR FIRE WALL PENETRATIONS - CONTRACTOR SHALL PROVIDE APPROVED UL LISTED FIRE
RATED ASSEMBLY OR SYSTEM TO MAINTAIN FIRE RATING OF EXISTING FIRE BARRIER.
9. THE OWNER CLAIMS FIRST RIGHT OF REFUSAL FOR EXISTING EQUIPMENT. COORDINATE SALVAGE
REQUIREMENTS WITH THE OWNER PRIOR TO DEMOLITION. IDENTIFY, TAG, AND CAREFULLY
DECOMMISSION EQUIPMENT TO BE SALVAGED FOR THE OWNER. EQUIPMENT NOT WANTED BY THE
OWNER SHALL BE REMOVED FROM THE SITE AT THE CONTRACTOR'S EXPENSE.
DISCONNECT AND REMOVE EXISTING FIRE ALARM SYSTEM IN ITS ENTIRETY.D1
1/8" = 1'-0"1
ADMIN BUILDING PLAN - FIRE ALARM - DEMOLITION
NEW CODED NOTES:
COORDINATE EXACT LOCATION OF FACP WITH EXISTING CONDITIONS PRIOR TO CONSTRUCTION.1
WOOD
ALUMINUM
STEEL
EARTH
CONCRETE MASONRY UNITS
RIGID INSULATION
CONCRETE
EXISTING CONSTRUCTION
TO REMAIN
EXISTING CONSTRUCTION
TO BE REMOVED
BRICK
WOOD-FINISHED
WOOD ROUGH
PLYWOOD
GYPSUM - PLASTER
ACOUSTIC TILE
CAST STONE
ALL METALS - SMALL SCALE
GLASS - LARGE SCALE
BATT INSULATION
CERAMIC TILE
CARPET
GRAVEL
CENTER LINE
DETAIL INDICATOR
DETAIL INDICATIOR
DIMENSION LINE
DRAWING BLOCK TITLE, TYPICAL
ELEVATION INDICATOR, EXTERIOR
ELEVATION INDICATOR, INTERIOR, MULTIPLE VIEW
ELEVATION INDICATOR, INTERIOR, SINGLE VIEW
SECTION INDICATOR
TYPICAL DETAIL INDICATOR
COLUMN GRID
KEYNOTE
NORTH ARROW
A
DETAIL NUMBER
SHEET WHERE
DRAWN
XXxxx
XXxxx
X
DRAWING TITLE
SCALE: 1 1/2" = 1'-0"
1 1/2"
XXxxx
XXxxx
XXxxx
REVISION
REVISION CLOUD
NORTH
BREAK LINE
DEMOLITION KEYNOTE
A
XXxxx
D
BC
COLUMN NUMBER
COLUMN LETTER
XXxxx
ELEVATION NUMBER
SHEET WHERE
DRAWN
ELEVATION NUMBER
SHEET WHERE
DRAWN
ELEVATION NUMBER
SHEET WHERE
DRAWN
DETAIL NUMBER
SHEET WHERE DRAWN
DETAIL NUMBER
SHEET WHERE DRAWN
SHEET WHERE
DRAWN
ELEVATION NUMBER
DOOR / BORROWED LIGHT TAG
FURNITURE, FIXTURE, & EQUIPMENT TAG
WALL/PARTITION TAG
x'-x" VERTICAL HEIGHT INDICATOR
ROOM NAME
3333333333
A3
ROOM NUMBER
ROOM AREA
PROGRAM AREA
D1
FLR FLOOR
FLUOR FLUORESCENT
FM FLOOR MATS & FRAMES
FO __ FACE OF __
FOC FACE OF CONCRETE
FOS FACE OF STUD
FOW FACE OF WALL
FP FOLDING PANEL PARTITION
FPRF FIREPROOF(ING)
FR FIRE RATING, FRAME
FRMG FRAMING
FS FULL SIZE, FEATURE STRIPS
FT FOOT OR FEET, FLOOR TILE MOSAIC
FTCT CERAMIC MOSAIC TILE
FTG FOOTING
FUR FURRING
FUT FUTURE
GA GAUGE
GAL GALLON
GALV GALVANIZED
GALV STL GALVANIZED STEEL
GB GRAB BAR
GC GENERAL CONTRACTOR
GCMU GLAZED FACE CMU
GD GUARD
GL GLASS
GND GROUND
GR GRADE
GT GRANITE
GUMU GLASS MASONRY UNIT
GWB GYPSUM WALLBOARD
GYP BD GYPSUM WALLBOARD
HB HOSE BIBB
HC HOLLOW CORE
HD HEAD
HDWD HARDWOOD
HDWR HARDWARE
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HMF HOLLOW METAL FRAME
HNDRL HANDRAIL
HO HOLD OPEN
HORIZ HORIZONTAL
HP HIGH POINT
HPDL PLASTIC LAMINATE
HR HANDRAIL, HOUR
HSPL HIGH STRENGTH PLASTER
HT HEIGHT
HVAC HEATING, VENTILATION, AIR
CONDITIONING
IBC INTERNATIONAL BUILDING CODE
ID IDENTIFICATION, INSIDE DIAMETER /
DIMENSION
IN INCH
INCL INCLUDE(D)
INSUL INSULATION
INT INTERIOR
INV INVERT
JAN JANITOR
JST JOIST
JT JOINT
KC PLASTER KEENE CEMENT
KP KICK PLATE
KO KNOCKOUT
L LENGTH
LAB LABORATORY
LAM LAMINATE
LAV LAVATORY
LBS POUND
LED LIGHT EMITTING DIODE
LF LINEAR FEET
LG LONG
LH LEFT HAND
LIN LINEAR
LIQ LIQUID
LKR LOCKER
LL LEAD LINED
LLV LONG LEG VERTICAL
LM LATEX MASTIC FLOORING
LMC LINEAR METAL CEILING
LP LOW POINT
LRG LARGE
LT LIGHT
LT WT LIGHTWEIGHT
LVR LOUVER
LWC LINEAR WOOD CEILING
M MORTAR
MAS MASONRY
MAT MATERIAL
MAX MAXIMUM
MB MARBLE
MC MULTI-COLOR COATING
MECH MECHANICAL
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MP MOP PLATE
MTD MOUNTED
MTL METAL
N NORTH
NA NOT APPLICABLE
NEC NATIONAL ELECTRICAL CODE
NEG NEGATIVE
NF NATURAL FINISH
NFC NATIONAL FIRE CODE
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER / DIMENSION
OFF OFFICE
OH OPPOSITE HAND, OVERHEAD
OPNG OPENING
OPP OPPOSITE
OZ OUNCE
P PAINT
PAV PAVING
PC PRECAST CONCRETE
PCT PORTLAND CEMENT TERRAZZO
PFW POLYPROPYLENE FABRIC WALLCOVERING
PL PLATE, PLASTER
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLYWD PLYWOOD
PMF PREMOLDED FILLER, PERFORATED METAL
FACING (TILE OR PANELS)
PPT PORCELAIN PAVER TILE
PR PAIR
PT POINT
PTN PARTITION
PVT PAVER TILE
QT QUARRY TILE
R RADIUS, RISER
RA RETURN AIR
RAD RADIUS
RB RESILIENT BASE, RUBBER BASE
RCP REFLECTED CEILING PLAN,
RADIANT CEILING PANEL SYSTEM
RD ROOF DRAIN
REF REFERENCE
REFR REFRIGERATOR
REQ'D REQUIRED
REV REVISION
RFI REQUEST FOR INFORMATION
RFP REQUEST FOR PROPOSAL
RH RIGHT HAND
RL ROOF LEADER
RM ROOM
RO ROUGH OPENING
RST RESILIENT STAIR TREAD
RT RUBBER TILE FLOORING
S SOUTH
SA SUPPLY AIR
SAN SANITARY
SC SOLID CORE, HIGH GLAZED COATING,
STRUCTURAL CLAY
SCHED SCHEDULE
SCT FACING TILE
SDG SUSPENSION DECORATIVE GRIDS
SECT SECTION
SF SQUARE FEET, STONE FLOORING
SFTU GLAZED STRUCTURAL FACING TILE
SH SPRINKLER HEAD
SHT SHEET
SIM SIMILAR
SLG SPANDREL GLASS
SM SMOKE
SPEC SPECIFICATION
SPKR SPEAKER
SQ SQUARE
SS STAINLESS STEEL
ST STAIN
STA STATION
STD STANDARD
STO STORAGE
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
SYM SYMMETRICAL
SYS SYSTEM
T TREAD
T&G TONGUE AND GROOVE
TEL TELEPHONE
TEMP TEMPERED
TGC TEXTURED GYPSUM CEILING PANEL
THK THICK
TIL TECHNICAL INFORMATION LIBRARY (VA)
TMC TEXTURED METAL CEILING PANEL
TOC TOP OF CONCRETE
TOP TOP OF PAVEMENT
TOS TOP OF STEEL
TOW TOP OF WALL
TST THIN SET TERRAZZO
TT TERRAZZO TILE
TV TELEVISION
TYP TYPICAL
UNFIN UNFINISHED
UON UNLESS OTHERWISE NOTED
VB VAPOR BARRIER, VINYL BASE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VIF VERIFY IN FIELD
VP VENEER PLASTER
VSF VINYL SHEET FLOORING
VTR VENT THRU ROOF
W WEST, VINYL COATED FABRIC
WALLCOVERING
W/ WITH
WB WALL BORDER
WD WOOD
WF FABRIC WALLCOVERING
W/O WITHOUT
WP WATERPROOF
WSF VINYL SHEET FLOORING (WELDED SEAMS)
WT WEIGHT
WWF WELDED WIRE FRAME
NOTES
1. ALL ABBREVIATIONS SHOWN MAY NOT BE USED ON THIS PROJECT.
2. CERTAIN COMMON ABBREVIATIONS MAY NOT BE SHOWN.
3. TEXT IN BOLD DENOTES ABBREVIATIONS FROM THE TIL.
L
& AND
@ AT
C CENTERLINE
# NUMBER, POUND
AA ANODIZED ALUMINUM, NATURAL FINISH
AAC ANODIZED ALUMINUM, COLORED
AB ANCHOR BOLT
ABA ARCHITECTURAL BARRIERS ACT
ABV ABOVE
ACT ACOUSTIC CEILING TILE
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADJ ADJUSTABLE
AF ACCESS FLOORING
AFF ABOVE FINISHED FLOOR
AFP ACCORDION FOLDING PARTITION
AHU AIR HANDLING UNIT
AIA AMERICAN INSTITUTE OF ARCHITECTS
ALT ALTERNATE
ALUM ALUMINUM
AMP ACOUSTICAL METAL PLAN CEILING
AP ACCESS PANEL
APPROX APPROXIMATE
ARCH ARCHITECTURAL
AT ACOUSTICAL CEILING TILE
AT (SP) ACOUSTICAL CEILING, SPECIAL FACED
AUTO AUTOMATIC
AVG AVERAGE
AWF ACOUSTICAL WALLCOVERING
AWP ACOUSTICAL WALL PANEL
AWT ACOUSTICAL WALL TREATMENT
BD BOARD
BE BAKED ON ENAMEL
BEL BELOW
BF BRICK FLOORING
BLDG BUILDING
BLK BLOCK
BM BEAM
BOT BOTTOM
BP BRICK PAVING
BR BUMPER RAIL, BRICK FACE
BRG BEARING
BRK BRICK
C, CONC CONCRETE
CAB CABINET
CAF CARPET ATHLETIC FLOORING
CB CATCH BASIN
CCT CUBICLE CURTAIN TRACK
CEM CEMENT
CG CORNER GUARD
CGFB CERAMIC GLAZED FACING BRICK
CI CAST IRON
CIP CAST IN PLACE
CJ CONTROL JOINT
CL CLOSET
CLG CEILING
CMU CONCRETE MASONRY UNIT
CO CONTRACTING OFFICER
COL COLUMN
CONF CONFERENCE
CONT CONTINUOUS
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CP CARPET
CPT CARPET MODULE TILE
CT CERAMIC TILE
CU CUBIC
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DISP DISPENSER
DN DOWN
DO DOOR OPENING
DOZ DOZEN
DP DAMPPROOFING
DR DOOR
DS MB DIVIDER STRIPS, MARBLE
DWG DRAWING
DWGS DRAWINGS
DWR DRAWER
E EAST, EXISTING
EA EXHAUST AIR, EACH
EC EPOXY COATING
EFS EXTERIOR FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATION
EMER EMERGENCY
ENCL ENCLOSURE
ENGR ENGINEER
EP ELECTRICAL PANELBOARD
EQ EQUAL
EQUIP EQUIPMENT
ERF EPOXY RESIN FLOORING
EWC ELECTRIC WATER COOLER
EWS EYE WASH STATION
EXIST EXISTING
EXP EXPANSION, EXPOSED DIVIDER STRIPS
EXT EXTERIOR
FA FIRE ALARM
FB FACE BRICK
FC FLUOROCARBON
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FACE
FG FOOT GRILLE
FHC FIRE HOSE CABINET
FIN FINISH
F
10987654321
E
D
C
B
A
10987654321
E
D
C
B
A
Revisions: Date:
CONSULTANTS:
CB DESIGN GROUP
(601)-278-0966
Integrity Federal Services- The LA Group Joint Venture, LLC
ABOVE GROUP
(321)-345-9026
AQUA ENGINEERING
(970)-372-6104
ARCHITECT/ENGINEER OF RECORD
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725- 8456
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
Office of Design and
Construction Service
U.S. Department of Veterans Affairs
STAMP
Drawing Title:
Approved: Project Director
Phase: Project Title:
Location:
Issue Date: Checked Drawn:
Drawing Number:
Project Number:
Building:
F
SYMBOLS, ABBREVIATIONS & NOTES-
ARCHITECTURE
BID DOCUMENTS
FAYETTEVILLE NATIONAL CEMETERY
COLUMBARIUM AND IN-GROUND CREMAINS
BURIAL EXPANSION
FAYETTEVILLE, ARKANSAS
MAY 20,2025 LTCKJ
GI200
842CM3027
SYMBOLS OF MATERIALSDRAWING SYMBOLSARCHITECTURAL ABBREVIATIONS
Dwg 80 of 121
IN STRIVING TO PROVIDE A HEALTHY AND SAFE ENVIRONMENT AT VA FACILITIES, VHA IS
IMPLEMENTING A SMOKE-FREE POLICY FOR ALL VHA HEALTH CARE FACILITIES AND PROPERTY
ASSIGNED TO VHA THAT IS UNDER THE CHARGE AND CONTROL OF VA. THE POLICY APPLIES TO
CIGARETTES, CIGARS, PIPES OR ANY OTHER COMBUSTION OF TOBACCO, INCLUDING BUT NOT
LIMITED TO ELECTRONIC OR E-CIGARETTES, VAPE PENS OR E-CIGARS.
UNDER VHA DIRECTIVE 1085, ALL VHA HEALTH CARE FACILITIES WILL BE SMOKE-FREE FOR PATIENTS, VISITORS, CONTRACTORS, VOLUNTEERS AND VENDORS EFFECTIVE OCTOBER 1, 2019.
1. VA DESIGN MANUAL (PG-18-0)
2. VA DESIGN, QUALITY, AND STANDARD ALERTS
3. VA DESIGN GUIDES (PG-18-12)
4. VA DESIGN AND CONSTRUCTION
PROCEDURES (PG-18-3)
5. PHYSICAL SECURITY DESIGN MANUAL FOR VA
FACILITIES
6. VA FIRE PROTECTION DESIGN MANUAL
7. VA BARRIER FREE DESIGN GUIDE (PG-18-3)
8. VA SIGNAGE DESIGN GUIDE
9. VA MASTER SPECIFICATIONS
10. VA SUSTAINABLE DESIGN MANUAL
1. REFER TO SHEET AE301 FOR WALL TYPES AS REFERENCED ON PLANS WITH THE DIAMOND SYMBOL.
2. UNLESS NOTED OTHERWISE, WALLS MUST EXTEND TO THE ROOF OR FLOOR DECK ABOVE AND BE SEALED IN ACCORDANCE WITH THE
WALL TERMINATION DETAILS. REFER TO THE CODE STUDY PLAN FOR IDENTIFICATION OF ALL SMOKE AND FIRE WALL CONDITIONS.
PERIMETER CORRIDOR AND LOBBY WALLS MUST BE BUILT TO RESIST THE PASSAGE OF SMOKE.
3. DIMENSIONS ON PLANS ARE FROM FACE OF MASONRY TO FACE OF MASONRY, FACE OF MASONRY TO FACE OF GYPSUM BOARD OR FACE
OF GYPSUM BOARD TO FACE OF GYPSUM BOARD.
4. "FEC" SHOWN ON FLOOR PLAN INDICATES A FIRE EXTINGUISHER AND CABINET. BASIS OF DESIGN IS POTTER ROEMER MODEL # 3010 - 10 LB 4A: 80B:C UL RATED FIRE EXTINGUISHER AND ALTA 760 STAINLESS STEEL RECESSED CABINET.
5. UNLESS SPECIFICALLY INDICATED OTHERWISE, THE SAME WALL TYPE NEXT TO A DOOR OR OPENING TO CONTINUE OVER THE DOOR OR
OPENING.
6. PLAN LOCATION OF DOORS AND FRAMES RELATIVE TO THE PLANE OF THE WALL IS DIAGRAMMATIC ONLY. REFER TO THE REFERENCED
JAMB AND HEAD CONDITION DETAILS TO DETERMINE ACTUAL PLACEMENT OF DOOR AND FRAME.
7. DISTANCE FROM HINGE SIDE OF DOOR (MEASURED FROM OUTSIDE OF FRAME) TO INTERSECTING STUD WALL SHALL BE 4" UNLESS NOTED
OR DETAILED OTHERWISE.
8. DEPICTION OF EXISTING CONDITIONS IS BASED ON OWNER FURNISHED DOCUMENTS AND LIMITED FIELD OBSERVATIONS. EXISTING ELEMENTS AND CONDITIONS CONCEALED BY IN-PLACE EQUIPMENT AND FINISHES WERE NOT OBSERVED OR INVESTIGATED. ONCE CUTTING AND SELECTIVE DEMOLITION WORK IS COMPLETE, REPORT ANY CONFLICTS TO COR. THE CONTRACTOR SHALL MAKE ADJUSTMENTS AND /OR ALTERATIONS AS NECESSARY TO INSTALL COMPLETE AND OPERABLE SYSTEMS IN ACCORDANCE WITH THE CODES
HAVING JURISDICTION AT NO ADDITIONAL COST TO THE GOVERNMENT.
9. CONTRACTOR SHALL PROVIDE ALL BLOCKING REQUIRED TO ANCHOR ALL WALL AND CEILING MOUNTED ITEMS, INCLUDING BUT NOT
LIMITED TO TOILET ROOM ACCESSORIES, MILLWORK, CASEWORK, HANDRAILS, ETC.
10. REFER TO AE200 FOR DOOR SCHEDULE AND FOR DOOR AND FRAME TYPES.
11. CONTRACTOR SHALL VERIFY ALL DIMENSIONS NOTED AS "CLEAR" OR "HOLD". THESE DIMENSIONS ARE CRITICAL TO COORDINATE WITH
OTHER WORK (E.G. METAL STUDS, CEILINGS, LIGHTING, FINISHES).
12. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND LAY OUT WALLS ON FLOOR PRIOR TO INITIATING CONSTRUCTION. REPORT
DISCREPANCIES TO COR PRIOR TO COMMENCING WORK.
13. ALL PENETRATIONS THROUGH RATED FLOOR/CEILING ASSEMBLIES AND THROUGH FIRE RATED WALL AND SMOKE BARRIER ASSEMBLIES -
(THOSE CREATED BY REMOVAL OF DEMOLISHED ITEMS UNDER THIS CONTRACT, THOSE DISCOVERED DURING CONSTRUCTION UNDER THIS CONTRACT AS A RESULT OF PREVIOUS WORK, AND THOSE CREATED BY NEW WORK UNDER THIS CONTRACT) - MUST BE FIRE SEALED AS PART OF THIS CONTRACT. ALL RATED SEPARATIONS MUST MEET CURRENT CODE REQUIREMENTS.
14. MECHANICAL EQUIPMENT SHOWN FOR REFERENCE ONLY. SEE MECHANICAL DRAWINGS FOR MORE INFORMATION.
1. ALL WORK SHOWN IS EXISTING TO REMAIN UNLESS NOTED OR INDICATED AS DASHED LINES TO BE REMOVED. THE EXTENT OF DEMOLITION WORK SHALL INCLUDE ALL INCIDENTAL DEMOLITION WORK NECESSARY TO PROPERLY PROVIDE ALL NEW WORK SHOWN AND SPECIFIED, INCLUDING MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS.
2. DEMOLITION WORK SHOWN IS BASED ON EXISTING DRAWINGS AND INSPECTIONS. THE CONTRACTOR SHALL VISUALLY INSPECT ALL EXISTING CONDITIONS, AND IS RESPONSIBLE FOR PERFORMING THE INDICATED DEMOLITION WORK EVEN IF ACTUAL CONDITIONS DIFFER FROM THOSE
SHOWN ON THE DRAWINGS.
3. DEMOLITION CONTRACTOR SHALL COORDINATE WITH NEW WORK SECTIONS FOR ADDITIONAL INFORMATION RELATED TO EXTENT OF
DEMOLITION.
4. REFER TO ALL OTHER DRAWINGS IN THIS SET FOR INCIDENTAL DEMOLITION WORK NOT NOTED ON THE DEMOLITION PLANS.
5. THE OWNER HAS FIRST RIGHT OF REFUSAL OF ALL SALVAGE ITEMS. THE CONTRACTOR SHALL PROPERLY DISPOSE OF ALL CONSTRUCTION
DEBRIS. DO NOT STOCKPILE DEBRIS ON SITE.
6. ITEMS TO BE DEMOLISHED SHALL BE REMOVED COMPLETELY INCLUDING ALL ANCHORS, HANGERS, FASTENERS, PIPES, CONDUITS, DUCTS, ETC, UNLESS OTHERWISE INDICATED TO BE ABANDONED IN PLACE.
7. CONCRETE SLAB PATCHES MUST BE FLUSH WITH REMAINING SURFACES TO PERMIT APPLICATION OF FINISHES. PROVIDE WELDED WIRE MESH
IN PATCH AREAS GREATER THAN FOUR (4) SQUARE FEET.
8. CONCRETE SLABS TO REMAIN SHALL BE PATCHED, SCRAPED, LEVELED, AND CLEANED TO PROVIDE SURFACE SUITABLE FOR NEW FINISHES.
WHERE RENOVATED AREAS ARE RECEIVING NEW UNDERGROUND MECHANICAL, PLUMBING, ELECTRICAL, OR ADDITIONAL FOUNDATION WORK, SEE MECHANICAL, PLUMBING, ELECTRICAL, AND STRUCTURAL DRAWINGS, IN ADDITION TO ARCHITECTURAL DRAWINGS, TO DETERMINE EXTENT OF REQUIRED CUT AND PATCH OF EXISTING SLAB. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL CONCRETE SLAB DEMOLITION AND REPLACEMENT NECESSARY TO INSTALL NEW WORK. BACKFILL ALL BELOW GRADE DEMOLITION WORK WITH SUITABLE FILL MEETING
STRUCTURAL REQUIREMENTS FOR NEW WORK.
9. PARTITIONS SHOWN TO BE REMOVED SHALL BE CONFIRMED BY THE CONTRACTOR AS TO TYPE OF PARTITION AND EXACT LOCATION.
COMPLETELY REMOVE PARTITIONS FROM FLOOR TO STRUCTURE, INCLUDING ALL FASTENERS, GROUTS, SEALANTS, ETC, UNLESS NOTED OTHERWISE. MASONRY PARTITIONS WHICH EXTEND THROUGH THE SLAB SHALL BE REMOVED TO 8" BELOW FINISH FLOOR. FILL SLAB OPENING WITH CONCRETE FILL TO RECEIVE FLOOR FINISH. WHERE WALLS SCHEDULED TO BE REMOVED SIT ON SLABS, GRIND SLAB TO
RECEIVE FLOOR FINISH.
10. REMOVE, PATCH, AND REPAIR PORTIONS OF WALL PARTITIONS WHICH CONFLICT WITH NEW WORK TO BE INSTALLED, EVEN IF NOT
SPECIFICALLY NOTED TO BE DEMOLISHED ON PLANS.
11. WALLS TO BE REMOVED FROM INTERSECTING MASONRY WALLS SHALL INCLUDE TOOTHED-IN REPLACEMENT OF DAMAGED MASONRY ON WALL TO REMAIN AND REMOVAL OF TIES PROJECTING FROM WALLS. SEE DETAILS FOR ADDITIONAL CONDITIONS.
12. MASONRY WALLS TO BE PARTIALLY REMOVED SHALL BE TERMINATED WITH FINISHED MASONRY ENDS BY TOOTHING IN NEW MASONRY UNITS TO MATCH ADJACENT MASONRY. SEE DETAILS FOR OTHER CONDITIONS. NO WALLS SHALL BE TERMINATED WITH EXPOSED OPEN CELLS OR
DAMAGED MASONRY UNITS.
13. WHERE NEW OPENINGS ARE SHOWN IN EXISTING WALLS, REMOVE MASONRY TO NEAREST JOINT LINE SO NEW WORK CAN BE PATCHED IN TO
MATCH. ALL NEW MASONRY WORK SHALL BE TOOTHED IN.
14. ALL EXISTING STRUCTURE SHALL REMAIN, UNLESS NOTED OTHERWISE.
15. COORDINATE DEMOLITION OF ALL STRUCTURAL ITEMS (COLUMNS, BEAMS, SLABS, ETC) WITH STRUCTURAL DRAWINGS. EXTENT OF
DEMOLITION AREA SHALL BE IN ACCORDANCE WITH STRUCTURAL REQUIREMENTS AND COORDINATED WITH ALL NEW WORK.
16. TEMPORARILY SUPPORT ALL BEAMS, LINTELS, PORTIONS OF WALLS, ETC, TO BE DISTURBED BY DEMOLITION WORK UNTIL THEY ARE RE-
SUPPORTED BY NEW WORK.
17. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE INTEGRITY OF EXISTING BUILDING ELEMENTS TO REMAIN THROUGHOUT THE
SEQUENCE OF WORK. ANY DAMAGE TO EXISTING BUILDING CONDITIONS SHOWN TO REMAIN SHALL BE RESTORED TO NEW WORK CONDITION
AT NO ADDITIONAL COST TO THE OWNER.
18. WINDOWS SCHEDULED FOR REMOVAL SHALL BE REMOVED COMPLETELY. FASTENERS MAY BE CUT FLUSH WITH HEAD, JAMBS, AND SILLS IF THE NEW WINDOW UNIT WILL CONCEAL FASTENER. PROTECT EXISTING SILLS SCHEDULED TO REMAIN. ALL EXISTING WINDOW OPENINGS
MUST BE FIELD MEASURED PRIOR TO SUBMITTAL OF SHOP DRAWINGS.
19. WHERE FINISHES ARE INDICATED TO BE REMOVED, REMOVAL SHALL INCLUDE ANY GROUT, ADHESIVES, FASTENERS, AND ALL OTHER ITEMS
USED TO ATTACH THE FINISHES TO THE SURFACES THEY COVER.
20. WHERE CEILINGS ARE TO BE REMOVED, REMOVE ALL CEILING SYSTEMS COMPLETELY, INCLUDING GRID, TRIM, HANGERS, CLIPS, ETC. DOUBLE CEILINGS ARE NOT PERMITTED WHERE NEW CEILINGS ARE SPECIFIED. REMOVE ALL ORIGINAL CONCEALED CEILINGS WHERE ENCOUNTERED.
21. ALL EXISTING SURFACES TO REMAIN SHALL BE PROTECTED, PATCHED/REPAIRED/REPLACED IF DAMAGED, AND CLEANED PRIOR TO
APPLICATION OF FINISHES.
22. CONTRACTOR SHALL PROTECT ALL EQUIPMENT AND OTHER EXISTING ELEMENTS IN SCOPE OF NEW WORK AND DEMOLITION AREA.
23. REMOVE ALL WINDOW TREATMENTS IN AREAS OF RENOVATION AND DEMOLITION UNLESS NOTED OTHERWISE.
24. REFER TO CIVIL, MECHANICAL, ELECTRICAL, STRUCTURAL, FIRE PROTECTION, LIFE SAFETY, AND HAZMAT DRAWINGS FOR ADDITIONAL
DEMOLITION NOTES.
1. ITEMS AND CONDITIONS NOTED, DETAILED, OR OTHERWISE IDENTIFIED ON DRAWINGS ARE APPLICABLE AND BINDING TO SIMILAR CONDITIONS ON ALL DRAWINGS. FOR CONDITIONS NOT NOTED OR NOT DETAILED, PROVIDE MATERIALS OF EQUAL QUALITY AND PERFORMANCE TO OTHER
SIMILAR CONDITIONS ON THE JOB.
2. SECTIONS SHOWN ARE INTENDED TO SHOW THE SPECIFIC CONSTRUCTION WHERE INDEXED AS WELL AS ESTABLISH THE GENERAL CONSTRUCTION DETAILS FOR SECTIONS THROUGHOUT THE PROJECT. ANY SPECIFIC QUESTIONS CONCERNING CONSTRUCTION NOT ADEQUATELY COVERED BY THE ABOVE SHOULD BE DIRECTED TO THE CONTRACTING OFFICER DURING THE BID PERIOD.
3. ALL CONSTRUCTION IS TO BE NEW AND FURNISHED AND INSTALLED BY THE CONTRACTOR, UNLESS NOTED OTHERWISE.
4. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR NOTES PERTAINING TO THEIR PARTICULAR DISCIPLINES. COORDINATE THE WORK OF ALL TRADES AND REPORT TO THE CONTRACTING OFFICER ANY PERCEIVED DISCREPANCIES. CONTRACTOR SHALL BE RESPONSIBLE FOR ESTABLISHING SEQUENCES OF CONSTRUCTION AND MEANS AND METHODS FOR HOW TO PERFORM THE WORK REQUIRED IN THE CONTRACT
DOCUMENTS.
5. CONTRACTOR SHALL CAREFULLY REVIEW ALL EXISTING CONDITIONS AND DETERMINE THE MOST FEASIBLE SEQUENCE FOR PERFORMING THE
NEW WORK SOLE AS TO AVOID CONFLICTS IN THE FIELD.
6. ANY AREAS OR SPACES NOT CLEARLY DEFINED OR INDICATED BY NOTES SHALL BE OF SAME MATERIAL AND FINISH AS AREAS OF SIMILAR USE
OR FUNCTION ELSEWHERE IN THE BUILDING.
7. WALL AND CEILING FINISHES SHALL INCLUDE PROJECTIONS, BEAM ENCLOSURES, RECESSES, BULKHEADS, PILASTERS AND OTHER SIMILAR
ITEMS.
8. ALL APPURTENANCES BUILT INTO OR THROUGH WALLS, INCLUDING DOORS, WINDOWS, DUCTS, FRAMES, LOUVERS, GRILLES, MECHANICAL WORK, ETC., SHALL FIT SNUGLY AND BE THOROUGHLY SEALED AROUND PERIMETERS. INSTALL FIRE SEALANT AROUND ALL PENETRATIONS THROUGH FLOORS, FIRE RATED WALLS AND SMOKE PARTITIONS IN ACCORDANCE WITH A UL LISTED ASSEMBLY. WORK AT EXTERIOR WALLS
SHALL BE FLASHED OR OTHERWISE WATERPROOF SEALED.
9. FIELD CHECK ROUGH AND/OR FINISHED DIMENSIONS FOR ACCURATE FITTING OF CABINETS, COUNTERS, STOREFRONT, DOORS, FRAMES, FIXTURES, MILLWORK AND ALL OTHER INSTALLATIONS PRIOR TO SHOP OR FACTORY FABRICATION. PROVIDE AND INSTALL NECESSARY FILLER STRIPS, SCRIBE STRIPS, BASES, CLOSURES, FINISHES AND TRIM TO COMPLETE SUCH INSTALLATIONS. DIMENSIONS OF SUCH INSTALLATIONS SHALL BE CONSIDERED "NOMINAL". CONTRACTORS SHALL ACCOUNT FOR ALL MANUFACTURER'S REQUIRED TOLERANCES, CLEARANCES AND
SHIM SPACE TO ENSURE PROPER INSTALLATION OF THE NEW WORK.
10. IF A DISCREPANCY APPEARS TO EXIST BETWEEN DRAWINGS AND/OR SPECIFICATIONS, THE MORE STRINGENT (TYPICALLY THE MORE COSTLY) REQUIREMENT SHALL APPLY. ITEMS DESCRIBED ON DRAWINGS, BUT NOT SPECIFIED, SHALL BE PROVIDED. CONTRACTOR SHALL BE RESPONSIBLE TO SUBMIT AN RFI TO SEEK CLARIFICATION OF ANY PERCEIVED DISCREPANCY DURING BID PHASE.
11. WRITTEN INFORMATION ON DRAWINGS TAKES PRECEDENT OVER DRAWING LINES.
12. IN THE ABSENCE OF A WRITTEN DIMENSION, OR IN CASE OF DOUBT AS TO THE PROPER MEASUREMENT, CONSULT CONTRACTING OFFICER . DO NOT SCALE DRAWINGS. ASSUMPTIONS MADE, OR ACTIONS TAKEN, BASED ON SCALED DIMENSIONS SHALL BE AT THE CONTRACTOR'S RISK AND ANY RESULTING CORRECTIONS SHALL BE PERFORMED BY CONTRACTOR AT NO ADDITIONAL COST TO THE GOVERNMENT.
13. EACH CONTRACTOR OR SUB-CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH THE WORK OF OTHER TRADES SHOWN THROUGHOUT THE COMPLETE SET OF CONTRACT DOCUMENTS. CHANGES RESULTING FROM A CONTRACTOR OR SUB-CONTRACTOR'S FAILURE TO OBTAIN AND REVIEW A COMPLETE SET OF CONTRACT DOCUMENTS SHALL BE CORRECTED AT NO ADDITIONAL COST TO THE GOVERNMENT.
14. AT ALL CHANGES IN FLOOR FINISHES, PROVIDE AND INSTALL AN APPROPRIATE TRANSITION STRIP AS SHOWN ON THE DRAWINGS.
15. CONSULT HVAC AND ELECTRICAL DRAWINGS FOR LOCATIONS AND DESCRIPTIONS OF ACCESS PANELS, LOUVER OPENINGS, VENTILATORS, GRILLES, VALVE CABINETS, FIRE DAMPERS OR OTHER APPURTENANCES AFFECTING WALLS, CEILINGS OR FLOORS AND PROVIDE NECESSARY
LINTELS, SUPPORT OR ANCHORING. IN COORDINATION WITH SHOP DRAWINGS.
16. ELECTRIC SWITCHES, OUTLETS, THERMOSTATS, CONTROLS, CLOCKS, SPEAKERS, OR OTHER WALL-MOUNTED ACCESSORIES SHALL BE INSTALLED IN LOCATIONS WHICH ARE UNOBSTRUCTED BY CABINETS, COUNTERS, RACKS, MARKER AND TACKBOARDS, FIXTURES, SHELVING OR OTHER FURNISHING OR EQUIPMENT DESIGNATED FOR SPACES SHOWN ON DRAWINGS. WALL MOUNTED ITEMS ARE NOT TO BE INSTALLED ON, THROUGH, OR INTO, ANY EQUIPMENT OTHER THAN WALLS, UNLESS SPECIFICALLY NOTED OTHERWISE.
17. ELECTRICAL OUTLETS, CLOCKS, P.A. SPEAKERS, PULL STATIONS, EXIT SIGNS, OR OTHER DEVICES SHOWN DIAGRAMMATICALLY ON THE ARCHITECTURAL DRAWINGS SERVE TO ALERT CONTRACTORS OF THE PRESENCE OF SUCH DEVICES. CONSULT THE ELECTRICAL DRAWINGS FOR FURTHER INFORMATION AND ADVISE CONTRACTING OFFICER OF ANY PERCEIVED DISCREPANCY BETWEEN ARCHITECTURAL AND ELECTRICAL DRAWINGS REGARDING LOCATION OR TYPE OF DEVICES SHOWN PRIOR TO PREPARING SUBMITTALS.
18. ELECTRIC SWITCHES, THERMOSTATS OR OTHER ELECTRONIC CONTROLS IN THE SAME VICINITY SHALL BE MOUNTED AT THE SAME HEIGHT FROM
FLOOR (UNLESS NOTED OTHERWISE) IN A UNIFORM, ORDERLY FASHION.
19. SUBMITTAL REVIEW - THE CONTRACT DOCUMENTS PROVIDE SIZES, DIMENSIONS, PRODUCT REQUIREMENTS, ETC. CONTRACTOR SHALL VERIFY THAT SUBMITTALS ARE COORDINATED WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS PRIOR TO SUBMISSION. A/E REVIEW OF SUBMITTALS IS NOT FOR THE PURPOSE OF DETERMINING THAT SIZES, DIMENSIONS, ETC MATCH WHAT HAS ALREADY BEEN PROVIDED IN THE CONTRACT DOCUMENTS. ALL DEVIATIONS FROM WHAT IS SHOWN ON THE CONTRACT DOCUMENTS SHALL BE CLOUDED ON THE SUBMITTAL OR OTHERWISE CLEARLY BROUGHT TO THE ATTENTION OF THE REVIEWER.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .