S02_Attachment 7_842CM3027_FYNC_Drawings.pdf
PDF 20 MB Posted
- Attached to
- Y1PZ--Fayetteville National Cemetery, Columbaria and In-ground Cremains Burial Expansion (VA-25-00092710)
- Solicitation number
- 36C78626B0001
About this file
This is a set of bid documents for the Fayetteville National Cemetery Columbarium and In-Ground Cremains Burial Expansion project in Fayetteville, Arkansas. The project number is 842CM3027 with an issue date of May 20, 2025. The contracting officer is within the U.S. Department of Veterans Affairs' Office of Design and Construction Service. The project involves the design and construction of a columbarium expansion facility, which includes precast concrete columbarium niche units, reinforced concrete walls and piers, Indiana limestone caps and base stones, brick veneer, cast bronze identification plaques and medallions, and associated landscaping and irrigation systems.
The bid documents include comprehensive architectural and structural drawings detailing columbarium elevations, niche unit sections, mounting brackets, weld plates, cap stones, and pier configurations across multiple detail sheets. Structural requirements specify concrete with a minimum 5,000 PSI compressive strength, Grade 60 reinforcing steel, concrete masonry units with 2,000 PSI minimum compressive strength, and footings designed for 2,000 PSF bearing pressure. The work also encompasses site landscaping with Astro Bermuda grass and stone mulch, automated irrigation systems with pop-up rotor and spray sprinklers, drainage systems, and utility coordination. Key design codes referenced include IBC 2024, ASCE 7-22, ACI 318-19, and TMS 402/602-22. The design team includes Integrity Federal Services and The LA Group as joint venture architect/engineers, with Aqua Engineering providing irrigation and civil engineering services. Submittal requirements include shop drawings for precast units, weld plates, niche covers, irrigation components, and concrete design mixes, all to be signed and sealed by licensed professional engineers registered in the local jurisdiction.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
24'-6" 2'-918"
PIER M1
16'-158"
2'-918"
PIER L4
24'-6" 2'-758"
PIER L3
EXISTING 36" REINFORCED
CONCRETE PIPE (RCP) TO
REMAIN
GRADE BEAM OVER
EXISTING PIPE
CI709
CI709
SHELF MC
1236.28
EXISTING GRADE, TYP.
FINISH GRADE, TYP.
TOP OF WALL /
PRECAST NICHES
(TOWL) 1245.46
CONC. JNT., TYP.
CONC.
JNT., TYP.
6'-4" 6'-4" 2'-6"
SHELF MB
1236.06
SHELF MA
1235.84 WALL 1 SHELF 3
1235.62
WALL 1 SHELF 2
1235.40
SHELF LC
1235.18
2'-0" 7'-8" 6'-558"
PIER M1 SHELF
1235.84
PIER L4 SHELF
1235.18
3'-4"
PIER L3 SHELF
1235.18
CI709
TOP OF WALL 1
(TOW1) 1238.90
CONC.
JNT., TYP.
SIM. SIM.
ADD NEW DETECTABLE
UNDERGROUND MAGNETIC WARNING
TAPE (BURIED STORM SEWER DRAIN
LINE BELOW) OVER EXISTING PIPE
THE LENGTH OF EXCAVATION.
CONTRACTOR TO PROVIDE
SUBMITTAL FOR APPROVAL.
28'-6" 2'-758"
PIER L2
24'-6" 2'-918"
PIER L1
16'-158"
CI709
CI709
SHELF LB
1234.96
EXISTING GRADE, TYP.
FINISH GRADE, TYP.CONC. JNT., TYP.
SHELF LA
1234.74 WALL 2
SHELF 3
1234.74
4'-4" 4'-4"
PIER L1 SHELF
1234.74
PIER L2 SHELF
1234.96
CI710
WALL 2
SHELF 2
1234.52
TOP OF WALL 2
1238.46
88'-312" 18'-158"
CONC. JNT., TYP.
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
FAYETTEVILLE, ARKANSAS
842CM3027
MAY 20, 2025 Dwg. of
Office of Design and Construction
Service U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
FAYETTEVILLE NATIONAL CEMETERY
COLUMBARIUM AND IN-GROUND
CREMAINS BURIAL EXPANSION
Fil e P ath
G:
\P
RO
J-2
4\2
_F
AY
ET
TE
VI
LL
E_
NA
TI
ON
AL
_C
EM
ET
ER
Y_
CO
LU
MB
AR
IU
M_
CR
EM
AI
NS
_E
XP
_F
CA
_R
EP
AI
RS
\20
3C
AD
\84
2C M3
7.0
.C I70
2.2
5.D W
G
CB Design Group
(601) 278-0966
Above Group
(321) 345-9026
05/20/25
Integrity Federal Services - The LA Group Joint Venture, LLC The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Aqua Engineering
(970) 372-6104
DBH JDB
CI707
COLUMBARIUM ELEVATIONS 6
1/2" = 1'-0"
COLUMBARIUM ELEVATION - HILL AVE 52 0 1' 2'6"
1/2" = 1'-0"
COLUMBARIUM ELEVATION HILL AVE 41 0 1' 2'6"
M
AT
CH
L
IN
E
SE
E
DE
TA
IL
/C I7
M
AT
CH
L
IN
E
SE
E
DE
TA
IL
/C I7
M
AT
CH
L
IN
E
SE
E
TH
IS
S
HE
ET
M
AT
CH
L
IN
E
SE
E
TH
IS
S
HE
ET
1'-8"1'-8"1'-8"
PIER SHELF
TOP OF FOUNDATION
1234.74
2'-0" 2'-0" 15'-6"
FINISH
GRADE, TYP.
EXISTING
GRADE, TYP.WALL 3 SHELF 10
1236.93
BOTTOM OF
FOOTING
(BFL) 1232.34
TOP OF FOOTING
(TFL) SEE STRUCT.
DWGS.
TOP OF PIER
(TOP) 1241.08
CI710
1158"1'-8"1'-8"1'-8"1'-8"1'-8"1'-238"
WALL 3 SHELF 9
1236.71
WALL 3 SHELF 8
1236.49
WALL 3 SHELF 7
1236.28
TOP OF WALL 3
1238.46
WALL 3
SHELF 5
1235.84
WALL 3
SHELF 1
1234.96
WALL 3
SHELF 2
1235.18
WALL 3
SHELF 3
1235.40
WALL 3
SHELF 4
1235.62
WALL 3
SHELF 6
1236.06
17'-6"
BRICK
VENEER
WRAPS
AROUND
WALLS,
TYP.
PLANE OF DEFLECTION
11 2"
FR
O
NT
7' -0
1' -41 2"
T O
1' -3
F
RO
NT
11 2"
F
RO
NT
1'
TO
TYP.
11 2"
F
RO
NT
4"
CONDITION
@ END
2"
(2) RECESSED WELDPLATES AT
EA. JOINT; STAINLESS STEEL, 1/4"
MIN. THICKNESS; PROVIDE SHOP
DRAWINGS
NICHE COVER
ATTACHMENT; SEE
PRE-CAST CONC. COLUMBARIUM
UNIT: UNIT SHALL BE 5 NICHES
HIGH, SEE LAYOUT PLANS FOR
RESPECTIVE DETAILS
1'
TO
TYP.
5 NICHE HIGH CLOSED PRECAST COLUMBARIUM UNIT
8, 9, OR 10 NICHE COLUMNS WIDE
(ELEVATION)
4" JNT.
NICHE JOINT BETWEEN PRECAST
CONC. COLUMBARIUM UNITS;
PROVIDE BACKER ROD AND
SEALANT AT ALL JOINTS (FRONT,
BOTTOM, SIDES, TOP, ETC.);
SEALANT COLOR SHALL BE
APPROVED BY THE COR.
NOTES:
1. ALL EXPOSED CONCRETE (NICHE
FRONTS) SHALL BE GROUND OR
PATCHED SMOOTH; APPLY COLOR COAT
AS SPECIFIED PRIOR TO NICHE COVER
INSTALLATION. PROVIDE SUBMITTAL.
2. RECESS WELD PLATES. SIZE, NUMBER, &
ATTACHMENT LOCATION SHALL BE AS
PER MANUFACTURER'S
RECOMMENDATION. PROVIDE SHOP
DRAWINGS FOR APPROVAL.
3. JOINTS BETWEEN UNITS SHALL BE
SEALED, WITH BACKER ROD AND
SEALANT.
4. VA PROVIDED NICHE COVERS,
CONTRACTOR INSTALLED.
FA
CE
O F
PR
E-
CA
ST
CO
NC
. U
NI
T
CI708
CI708
2" 1'-10"
1' -21 2"
AT
B
AC
K, TY
P. 1'-8" TYP.
11 2"
F
RO
NT
TY
P.
1' -3
F
RO
NT
TY
P.
FIELD DRILL HOLE
FOR 1/2" Ø S.S. PIN
(SEE INSTALLATION
DETAILS), TYP.
1/4"Ø HOLE
CAST-IN-PLACE
(TYP.)
5 NICHE HIGH PRECAST
COLUMBARIUM UNIT
(SECTION)
FIELD DRILL HOLE
FOR 1/2" Ø S.S. PIN
(SEE INSTALLATION
DETAILS), TYP.
RECESSED WELDPLATE;
STAINLESS STEEL, 1/4" MIN.
THICKNESS; ATTACH WITH WELD
PLATES SIDE TO SIDE, REAR TO
STEM WALL AND END TO PIER;
PROVIDE SHOP DRAWINGS.
ALIGN WEB CENTERLINES ON BACK
TO BACK NICHE UNITS. (TYP.)
PRE-CAST CONC. COLUMBARIUM
UNIT (TYP.); (STEEL REINFORCING
NOT SHOWN FOR CLARITY);
CONTRACTOR SHALL SUBMIT SHOP
DRAWINGS FOR APPROVAL WITH
PRECAST AND CAST-IN-PLACE
ATTACHMENTS
1/4"Ø HOLE CAST-IN-PLACE (TYP.)
0'-112"
0'-134"
@ BACK
0'-2"
@ BACK,
TYP.
0'-078"
1'-0"
TO
TYP.0'-112"@
FRONT, TYP.
1' -1
0"
0'-10"
TYP. 0'
-2
1' -8
5 NICHE HIGH PRECAST COLUMBARIUM UNIT
5, 8, OR 10 NICHE WIDE
(PLAN)
BACKER ROD AND SEALANT ALL
JOINTS INSIDE NICHE UNITS, TYP.
NICHE JOINT BETWEEN PRECAST
CONC. COLUMBARIUM UNITS;
*SPACING ACROSS JOINTS SHALL
BE MAINTAINED, TYP.-GRIND ENDS
IF NECESSARY; PROVIDE BACKER
ROD AND SEALANT AT ALL JOINTS
FRONT OF NICHE UNITS SEALANT
COLOR SHALL BE APPROVED BY
THE COR.
FIELD DRILL
HOLES FOR 1/2"
PINS, RECESS AND
EPOXY GROUT
FLUSH WITH
INSIDE. ADD FOG
COAT FOR
UNIFORM
APPEARANCE
INSIDE OF NICHE,
PATCH SHALL NOT
BE VISIBLE, TYP.
0'-1012"@
FRONT
TYP.
90.0°
LAYOUT LINE
CI708
NOTE:
WASHER THICKNESS AS NECESSARY TO ENSURE EDGE OF
ROSETTE DOES NOT TOUCH NICHE COVER WHEN FULLY
TIGHTENED. ROSETTE CAN NOT BE MORE THAN 1/16" AWAY
FROM NICHE COVER WHEN FULLY TIGHTENED.
STAINLESS STEEL ROSETTE (VA STANDARD),
SATIN FINISH, PROVIDE PRODUCT LITERATURE.
1" Ø
3/4" TO 7/8" O.D. WHITE OR CLEAR
NEOPRENE OR SILICONE WASHER
10-24 X 1 3/4" LENGTH STAINLESS
STEEL TAMPER-PROOF BOLT,
(SNAKE-EYE) BUTTON HEAD
FRONT ELEV. SECTION
STAINLESS STEEL
THREADED SPRING-CLIP
TO RECEIVE ROSETTE
BOLT
1 2"
1"
2"
2"
SIDE VIEW
PLAN VIEW
5/16" X 3/4"
SLOTS
4"
11 4"
3/32" THICK STAMPED
STAINLESS STEEL
ANGLE W/ (2) SLOTS
FRONT VIEW
11 2"
C L
4"1
4"
4"
5 16
TYP. CONDITION AT
BOTTOM OF PRECAST
UNIT
1/4" X 1 3/4" S.S. EXPANSION
BOLT, LOCK WASHER & HEX
NUT (TYP.)
1/4" Ø HOLE CAST-IN-PLACE
1/
4"
TY
P.
TYP. CONDITION AT
INTERMEDIATE SHELVES OF
PRECAST UNIT
1/4" X 3" S.S. THREADED ROD,
LOCK WASHER & HEX NUT (TYP.)
PLASTIC SHIMS, TYP.
1/4" Ø HOLE CAST-IN-PLACE (TYP.)
MOUNTING
BRACKET (TYP.)
3/4" Ø NEOPRENE OR
SILICONE WASHER
(TYP.), BEHIND
ROSETTE
ROSETTE & SPANNER
HEAD BOLT (TYP.)
V.A. PROVIDED NICHE
COVERS W/
PRE-DRILLED 3/8" Ø
HOLES TO ACCEPT
ROSETTE & BOLT;
CONTRACTOR
INSTALLED
1"
TYP.
CI708
CI708
TYP. CONDITION AT
TOP OF PRECAST UNIT
RECESSED HOLE
CAST-IN-PLACE TO
ACCOMMODATE CARRIAGE
BOLT FLUSH WITH TOP OF
PRECAST UNIT
S.S. CARRIAGE BOLT, LOCK
WASHER & HEX NUT 1/4" X 1
3/4"
HEAD OF CARRIAGE BOLT
TO BE FLUSH WITH TOP OF
PRECAST
SEE SPECIFICATIONS FOR
REQUIREMENTS FOR ROSETTE
SCREW ATTACHMENT AND
ALIGNMENT IN TOP ROW
1/
4"
TY
P.
SECTION (TOP)
AT NICHE UNITS
TOP WELD PLATE SHALL
BE FLUSH WITH
CONCRETE OR BELOW
CONCRETE SURFACE
TOP OF
NICHE UNIT
(1) 3" X 9" X 1/4" TOP S.S. WELD
PLATE. CONTROLLED WELDING
SHALL BE USED TO PREVENT
OVERHEATING AND CRACKING
OF CONCRETE
2"X6"X1/4" S.S. WELD
PLATE CAST INTO
PRE-CAST UNIT
4" STUBS, MIN.
JOINT BETWEEN
PRE-CAST NICHE
UNITS OR NICHE UNIT
AND CIP STEM WALL
2"X6"X1/4" S.S. WELD
PLATE CAST INTO
PRE-CAST UNIT
3/16" FILLET WELD ALL
AROUND WELD PLATE,
TYP.
SINGLE-SIDED COLUMBARIUM WALL AT PIER
PLAN (TOP)
8"(1) 3"X6"X1/4" S.S.
WELD PLATES CAST
INTO PRECAST NICHE
UNITS, TYP.
(1) 12"X6"X1/4" S.S.
WELD PLATE CAST INTO
CONC. WALL, TYP.
CONCRETE JOINT, TYP.
(1) 4"X3"X1/4" S.S. WELD
TOP PLATE, TYP.
SINGLE-SIDED COLUMBARIUM WALL
PLAN (TOP)
8"
CONC. WALL PRECAST NICHE
UNIT BACK, TYP.
(1) 6"X12"X1/4" S.S. WELD PLATE
CAST INTO CONC. WALL, TYP.
(2) 3"X6"X1/4" S.S. WELD
PLATES CAST INTO
PRECAST NICHE UNITS, TYP.
(1) 3"X9"X1/4" TOP S.S.
WELD PLATE, TYP.
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
FAYETTEVILLE, ARKANSAS
842CM3027
MAY 20, 2025 Dwg. of
Office of Design and Construction
Service U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
FAYETTEVILLE NATIONAL CEMETERY
COLUMBARIUM AND IN-GROUND
CREMAINS BURIAL EXPANSION
Fil e P ath
G:
\P
RO
J-2
4\2
_F
AY
ET
TE
VI
LL
E_
NA
TI
ON
AL
_C
EM
ET
ER
Y_
CO
LU
MB
AR
IU
M_
CR
EM
AI
NS
_E
XP
_F
CA
_R
EP
AI
RS
\20
3C
AD
\84
2C M3
7.0
.C I70
2.2
5.D W
G
CB Design Group
(601) 278-0966
Above Group
(321) 345-9026
05/20/25
Integrity Federal Services - The LA Group Joint Venture, LLC The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Aqua Engineering
(970) 372-6104
DBH JDB
CI708
COLUMBARIUM DETAILS 1
1" = 1'-0"
CLOSED PRECAST COLUMBARIUM NICHE UNIT (8,9, OR 10 NICHE COLUMNS WIDE)2 1'0 6"3"
1/2" = 1'-0"
COLUMBARIUM ELEVATION HILL AVE 61 0 1' 2'6"
M
AT
CH
L
IN
E
SE
E
DE
TA
IL
/C I7
NTS
COLUMBARIUM NICHE COVER ATTACHMENT6
1'-0" = 1'-0"
ROSETTE DETAIL3
1'-0" = 1'-0"
MOUNTING BRACKET4 0 1"
0 1"
NTS
COLUMBARIUM WELD PLATES5
AutoCAD SHX Text
TO
AutoCAD SHX Text
TO
AutoCAD SHX Text C
AutoCAD SHX Text L
AutoCAD SHX Text
TO
AutoCAD SHX Text C
AutoCAD SHX Text L
AutoCAD SHX Text
TO
FINISH GRADE
VARIES, SEE
GRADING PLAN
5 NICHE HIGH PRECAST CONC.
COLUMBARIUM NICHE UNIT (1/2" NOM.
SETTING GAP BETWEEN UNIT AND CIP.
SET UNITS SO FACE TO FACE IS AS
INDICATED.
CI708
CUT INDIANA LIMESTONE CAP
CONTINUOUS DRIP SLOT,
ALL OVERHANGS, TYP.
BACKER ROD & SEALANT 3/8" JOINT ALL AROUND
NICHE UNITS, TYP.
RECESSED S.S. WELD PLATES,
MIN. 2 PER NICHE UNIT, TYP.
TOP OF NICHES
TOP OF WALL
WALL TOP OF
FOUNDATION VARIES
FINISH GRADE
VARIES
1'-33 16" 1'-53
16"
2'-838"
NICHE COVER ATTACHMENT (MOUNTING
BRACKET & ROSETTES), TYP.
PIER (BEYOND), TYP.
GOVERNMENT PROVIDED AND CONTRACTOR
INSPECTED AND INSTALLED MARBLE NICHE
COVER, TYP.
FIELD DRILL HOLE IN COLUMBARIUM NICHE
FLOOR TO ACCEPT 1
2"Ø X 6" TYPE 304 S.S. PIN.
PROVIDE 2 PER PRECAST NICHE UNIT; PATCH
WITH MORTAR, FLUSH ON INSIDE, TYP.
3/8" BACKER ROD & SEALANT JOINT AT TOP,
BOTTOM, & SIDES OF PRECAST NICHES, TYP.
1/2" X 5" 304 S.S. PINS INSTALL NON-SHRINK
GROUT INTO TOP WEB AND LOOSE FIT INTO
CAP, (2) PINS PER CAP, TYP.
1'-713 16" 1'-33
16"
2'-11"
APPLY WATER PROOF MEMBRANE AND
DIMPLE DRAINAGE BOARD BELOW GRADE ON
FOUNDATION AND FOOTING, TYP.
FILTER FABRIC, TYP.
CONC. PAVEMENT W/THICKENED EDGE, TYP.
REINFORCED CONCRETE
FOUNDATION AND FOOTING;
SEE STRUCTURAL DRAWINGS
8"
EPDM MEMBRANE (45 MIL) OVER ENTIRE
TOP OF PRECAST NICHE UNITS & PIERS.
WRAP EXCESS DOWN VERTICAL FACE OF
CIP CONC., TYP.
1'-0"
TYP.
MIN. 2' DEPTH MOISTURE-CONDITIONED
IMPORTED SELECT FILL, SEE GEOTECH
REPORT. COMPACTED IN 8" LIFTS, MIN.
98% ASTM D698 (STANDARD PROCTOR)
5,6,7
CI716
LAYOUT LINE
8"
WALL SHELF
VARIES
GRIND AND PATCH EXPOSED
CONCRETE. FINISH: SACK RUB, TYP.
FLASHING AND DRIP
EDGE, TYP.
6" TY
P.
1' -0
" M
IN
16"
3/8" TYPE N MORTAR JOINT, TYP.
MODULAR BRICK VENEER (3 5/8" X 2 1/4" X
7 5/8"). BASIS OF DESIGN CHEROKEE RED
VELOUR. MATCH EXISTING BRICK AT HILL
AVE. GATE PIERS, TYP.
COMPACTED SUBGRADE
3/8" ROUNDED STONE; MATCH
EXISTING COLUMBARIUM J. STONE
SHALL BE 1/2" BELOW TOP OF
PAVEMENT, TYP.
304 S.S. MASONRY ANCHOR, MAX. 16"
O.C. HORIZONTAL AND VERTICAL, BASIS
OF DESIGN HB DW-10HS, TYP.
CI708
CI708
2" DIA. CAST BRONZE ROW LETTER
IDENTIFICATION MEDALLION, TYP.
PIER SHELF
VARIES (BEYOND)
REINFORCED
CONCRETE MOW
STRIP
6"
CI510
TOP OF
FOOTING
VARIES
BOTTOM OF
FOOTING
VARIES
2' -0
" M
IN
6"
TYP.
DRAINAGE AGGREGATE
BACKFILL WITH 6" DIA. PERF.
FOOTING DRAIN, HOLES DOWN,
W/F.F. SOCK (3 HOLE PERF.
PATERN), TYP. SEE DRAINAGE
PLANS
SE
E
ST
RU
CT
UR
AL
D
RA
W
IN
G
S
AIR CAVITY WITH 1" EXTRUDED POLYMER
MATRIX DRAINAGE MESH HEAT
LAMINATED TO A PERMEABLE FILTER
FABRIC; BAISS OF DESIGN: CAV-AIR-ATOR
1.0 BY KEENE. ATTACH DRAINAGE MESH
TO CIP CONCRETE WALL CORE WITH
ADHESIVE, TYP.
CI714
CI714
2,4
CI716
3" DIA. CAST BRONZE COLUMN
NUMBER MEDALLION
2"
PLASTIC MASONRY SHIMS, TYP.
1'-338"
SEE PLANS
AL
IG
N
16" 613
16"
EQ.
EQ.
CS510
CI714
8"1'-33
16" 1'-33 16"
TOP OF WALL
TOP OF NICHES
PIER SHELF
VARIES
TOP OF PIER
FNDN. VARIES
FINISH GRADE
VARIES
2'-638"
EPDM MEMBRANE (45 MIL) OVER
ENTIRE TOP OF PIERS. WRAP
EXCESS EPDM DOWN VERTICAL
FACES OF CIP PIER CORE.
CUT INDIANA LIMESTONE CAP,
SMOOTH FINISH
CONTINUOUS DRIP SLOT,
ALL OVERHANGS, TYP.
3/8" BACKER ROD &
SEALANT JOINT, TYP.
1/2" X 5" 304 S.S. PINS INSTALLED W/
TYPE N MORTAR. LOOSE FIT INTO
CAP, (2) PINS PER CAP, TYP.
LAYOUT LINE, TYP.
PARTIAL TYPE N MORTAR BED
(BLOBS), TYP.
PLASTIC MASONRY SHIMS, TYP.
REINFORCED CONCRETE PIER CORE;
SEE STRUCTURAL DRAWINGS, TYP.
AIR CAVITY WITH 1" EXTRUDED
POLYMER MATRIX DRAINAGE MESH
HEAT LAMINATED TO A PERMEABLE
FILTER FABRIC; BASIS OF DESIGN:
CAV-AIR-ATOR 1.0 BY KEENE. ATTACH
DRAINAGE MESH TO CIP PIER CORE
WITH ADHESIVE, TYP.
INDIANA LIMESTONE BASE STONE
SMOOTH FINISH, TYP.
8"
FINISH GRADE VARIES, SEE
GRADING PLAN
REINFORCED CONC.
MOW STRIP
6"
CI510
1'-33 16"
EQ.
1'-33 16"
EQ.
3/8" TYPE N MORTAR JOINT, TYP.
MODULAR BRICK VENEER (3 5/8" X 2 1/4" X
7 5/8"). BASIS OF DESIGN CHEROKEE RED
VELOUR. MATCH EXISTING BRICK AT HILL
AVE. GATE PIERS, TYP.
304 S.S. MASONRY ANCHOR, MAX. 16"
O.C. HORIZONTAL AND VERTICAL, BASIS
OF DESIGN HB DW-10HS, TYP.
BRICK VENEER BEYOND, TYP.
3/8" ROUNDED STONE; MATCH
EXISTING COLUMBARIUM J. STONE
SHALL BE 1/2" BELOW TOP OF
PAVEMENT, TYP.
1' -0
" M
IN
2'-15 16" 2'-15
16"
4'-258"
APPLY WATER PROOF
MEMBRANE AND DIMPLE
DRAINAGE BOARD BELOW
GRADE ON FOUNDATION
AND FOOTING, TYP.
REINFORCED CONCRETE
FOUNDATION AND FOOTING;
SEE STRUCTURAL DRAWINGS
1'-0"
TYP.
MIN. 2' DEPTH MOISTURE-CONDITIONED
IMPORTED SELECT FILL, SEE GEOTECH
REPORT. COMPACTED IN 8" LIFTS, MIN.
98% ASTM D698 (STANDARD PROCTOR)
6" TY
P.
COMPACTED SUBGRADE
TOP OF
FOOTING
VARIES
BOTTOM OF
FOOTING
VARIES
2' -0
" M
IN
6"
TYP.
DRAINAGE AGGREGATE
BACKFILL WITH 6" DIA. PERF.
FOOTING DRAIN, HOLES DOWN,
W/F.F. SOCK (3 HOLE PERF.
PATERN), TYP. SEE DRAINAGE
PLANS
SE
E
ST
RU
CT
UR
AL
D
RA
W
IN
G
S
CI712
CI712
CI711
CI711
CI711
CI711
CI712
CI712
CI713
SIM. SIM.
CI713
SIM. SIM.
CI712
SIM.
CI712
CI713
SIM. SIM.
CI713
CI713
SIM. SIM.
CI713
CI714
SIM. SIM.
FLASHING AND DRIP
EDGE, TYP.
CI714 SIM.
CONC. PAVEMENT
W/THICKENED EDGE, TYP.
CS510
BRONZE WALL IDENTIFICATION
PLAQUE, TYP.
CI714
5,6,7
CI716
BOTTOM OF
FENCE PANEL
1238.23
CUT INDIANA LIMESTONE CAP,
SMOOTH FINISH
CONTINUOUS DRIP SLOT,
ALL OVERHANGS, TYP.
3/8" BACKER ROD & SEALANT JOINT,
TYP.
1/2" X 5" 304 S.S. PINS INSTALLED W/ TYPE N
MORTAR. LOOSE FIT INTO CAP, (2) PINS PER
CAP, TYP.
PARTIAL TYPE N MORTAR BED
(BLOBS), TYP.
PLASTIC MASONRY
SHIMS, TYP.
FINISH GRADE
VARIES
LAYOUT LINE, TYP.
AIR CAVITY WITH 1" EXTRUDED
POLYMER MATRIX DRAINAGE
MESH, TYP.
FLASHING AND DRIP
EDGE, TYP.3
CI714
3/8" TYPE N MORTAR JOINT, TYP.
MODULAR BRICK VENEER, TYP.
304 S.S. MASONRY ANCHOR,
MAX. 16" O.C. HOR. & VERT., TYP.
EXISTING 36" CONCRETE REINFORCED PIPE TO
REMAIN. ASSUMED TOP OF PIPE ELEVATION
1234.03, TYP.
FINISH GRADE
VARIES, SEE
GRADING PLAN
REINFORCED
CONCRETE MOW
STRIP
CI510
CONC. PAVEMENT
W/THICKENED EDGE, TYP.
APPLY WATER PROOF MEMBRANE AND DIMPLE
DRAINAGE BOARD BELOW GRADE ON
FOUNDATION AND FOOTING, TYP.
PIER (BEYOND), TYP.
ORNAMENTAL (DECORATIVE)
FENCE. BASIS OF DESIGN:
AMERISTAR ECHELON II
GENESIS 3 RAIL W/ RINGS.
NOM. 8' LONG BY 5' HEIGHT
PANELS WITH 2 1/2" SQ.
POSTS WITH BALL CAP POST
FINIALS. COLOR BLACK.
FENCE PANELS ATTACHED
WITH FLAT-MOUNT
BRACKETS TO POSTS PER
MANUFACTURER'S
RECOMMENDATIONS.
PROVIDE EQUAL LENGTH
PANELS WITHIN EACH FENCE
RUN BETWEEN PIERS. LAST
PANEL IN EACH RUN MAYBE
WITHIN 12" OF EQUAL, TYP.
ASSUMED PIPE
ELEVATION 1230.70
BOTTOM OF GRADE BEAM
(BFGB) SEE STRUCTURAL
WALL SHELF
VARIES
TOP OF FNDN. /
SHELF
TOP OF WALL
3/8" ROUNDED STONE; MATCH EXISTING
COLUMBARIUM J. STONE SHALL BE 1/2"
BELOW TOP OF PAVEMENT, TYP.
1' -0
" M
IN
67 STONE, ASTM D448, TYP.
RECESSED WELD PLATE FOR
CUSTOM FENCE POST ATTACHMENT,
SEE STRUCTURAL, TYP.
16"
1'-6"
8"
8"83
4"
REINFORCED CONCRETE GRADE BEAM WALL
CORE; SEE STRUCTURAL DRAWINGS, TYP.
ADD NEW DETECTABLE UNDERGROUND
MAGNETIC WARNING TAPE (BURIED STORM
SEWER DRAIN LINE BELOW) OVER EXISTING
PIPE THE LENGTH OF EXCAVATION.
CONTRACTOR TO PROVIDE SUBMITTAL FOR
APPROVAL.
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
FAYETTEVILLE, ARKANSAS
842CM3027
MAY 20, 2025 Dwg. of
Office of Design and Construction
Service U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
FAYETTEVILLE NATIONAL CEMETERY
COLUMBARIUM AND IN-GROUND
CREMAINS BURIAL EXPANSION
Fil e P ath
G:
\P
RO
J-2
4\2
_F
AY
ET
TE
VI
LL
E_
NA
TI
ON
AL
_C
EM
ET
ER
Y_
CO
LU
MB
AR
IU
M_
CR
EM
AI
NS
_E
XP
_F
CA
_R
EP
AI
RS
\20
3C
AD
\84
2C M3
7.0
.C I70
2.2
5.D W
G
CB Design Group
(601) 278-0966
Above Group
(321) 345-9026
05/20/25
Integrity Federal Services - The LA Group Joint Venture, LLC The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Aqua Engineering
(970) 372-6104
DBH JDB
CI709
COLUMBARIUM DETAILS 2
1" = 1'-0"
SINGLE SIDED COLUMBARIUM WALL SECTION1 1'0 6"3" 1" = 1'-0"
SINGLE SIDED COLUMBARIUM PIER SECTION2 1'0 6"3" 1" = 1'-0"
GRADE BEAM SECTION3 1'0 6"3"
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
A
BOTTOM OF
FENCE PANEL
1237.79
CUT INDIANA LIMESTONE CAP,
SMOOTH FINISH
CONTINUOUS DRIP SLOT,
ALL OVERHANGS, TYP.
3/8" BACKER ROD & SEALANT JOINT,
TYP.
1/2" X 5" 304 S.S. PINS INSTALLED W/
TYPE N MORTAR. LOOSE FIT INTO CAP,
(2) PINS PER CAP, TYP.
PARTIAL TYPE N MORTAR BED
(BLOBS), TYP.
PLASTIC MASONRY SHIMS, TYP.
FINISH GRADE
VARIES
LAYOUT LINE, TYP.
REINFORCED CONCRETE GRADE BEAM WALL
CORE; SEE STRUCTURAL DRAWINGS, TYP.
AIR CAVITY WITH 1" EXTRUDED
POLYMER MATRIX DRAINAGE
MESH, TYP.
FLASHING AND DRIP EDGE, TYP.
3/8" TYPE N MORTAR JOINT, TYP.
MODULAR BRICK VENEER, TYP.
304 S.S. MASONRY ANCHOR, MAX. 16"
O.C. HOR. & VERT., TYP.
FINISH GRADE
VARIES, SEE
GRADING PLAN
REINFORCED
CONCRETE MOW
STRIP
CI510
CONC. PAVEMENT
W/THICKENED EDGE, TYP.
APPLY WATER PROOF MEMBRANE AND
DIMPLE DRAINAGE BOARD BELOW GRADE
ON FOUNDATION AND FOOTING, TYP.
PIER (BEYOND), TYP.
WALL SHELF
VARIES
TOP OF FNDN. /
SHELF
TOP OF WALL
3/8" ROUNDED STONE; MATCH EXISTING
COLUMBARIUM J. STONE SHALL BE 1/2"
BELOW TOP OF PAVEMENT, TYP.
1' -0
" M
IN
16"
1'-6"
REINFORCED CONCRETE
FOUNDATION AND FOOTING;
SEE STRUCTURAL DRAWINGS
1'-0"
TYP.
MIN. 2' DEPTH MOISTURE-CONDITIONED
IMPORTED SELECT FILL, SEE GEOTECH
REPORT. COMPACTED IN 8" LIFTS, MIN.
98% ASTM D698 (STANDARD PROCTOR)
6" TY
P.
COMPACTED SUBGRADE
TOP OF
FOOTING
VARIES
BOTTOM OF
FOOTING
VARIES
2' -0
" M
IN
6"
MIN.
TYP.
DRAINAGE AGGREGATE
BACKFILL WITH 6" DIA. PERF.
FOOTING DRAIN, HOLES DOWN,
W/F.F. SOCK (3 HOLE PERF.
PATERN), TYP. SEE DRAINAGE
PLANS
SE
E
ST
RU
CT
UR
AL
D
RA
W
IN
G
S
1'-713 16"
8"
4" 45
8"
CI714
RECESSED WELD PLATE FOR
CUSTOM FENCE POST ATTACHMENT,
SEE STRUCTURAL, TYP.
ORNAMENTAL (DECORATIVE)
FENCE. BASIS OF DESIGN:
AMERISTAR ECHELON II
GENESIS 3 RAIL W/ RINGS.
NOM. 8' LONG BY 5' HEIGHT
PANELS WITH 2 1/2" SQ.
POSTS WITH BALL CAP POST
FINIALS. COLOR BLACK.
FENCE PANELS ATTACHED
WITH FLAT-MOUNT
BRACKETS TO POSTS PER
MANUFACTURER'S
RECOMMENDATIONS.
PROVIDE EQUAL LENGTH
PANELS WITHIN EACH FENCE
RUN BETWEEN PIERS. LAST
PANEL IN EACH RUN MAYBE
WITHIN 12" OF EQUAL, TYP.
DRAINAGE AGGREGATE
BACKFILL WITH 6" DIA. PERF.
FOOTING DRAIN, HOLES DOWN,
W/F.F. SOCK (3 HOLE PERF.
PATERN), TYP. SEE DRAINAGE
PLANS
2'-0"
2'-113 16"
REINFORCED CONCRETE
FOUNDATION AND FOOTING;
SEE STRUCTURAL DRAWINGSBOTTOM OF
FOOTING
1'-0"
TYP.
MIN. 2' DEPTH
MOISTURE-CONDITIONED
IMPORTED SELECT FILL, SEE
GEOTECH REPORT
6" TY
P.
COMPACTED SUBGRADE
FINISH GRADE
VARIES, SEE
GRADING PLAN
REINFORCED CONCRETE MOW STRIP13
CI510
SE
E
ST
RU
CT
UR
AL
D
RA
W
IN
G
S
APPLY WATER PROOF
MEMBRANE AND DIMPLE
DRAINAGE BOARD BELOW
GRADE ON FOUNDATION
AND FOOTING, TYP.
TOP OF
FOOTING
PIER SHELF
TOP OF FOUNDATION
AIR CAVITY WITH EXTRUDED POLYMER MATRIX
DRAINAGE MESH HEAT LAMINATED TO A PERMEABLE
FILTER FABRIC; BASIS OF DESIGN: CAV-AIR-ATOR 0.4
BY KEENE. ATTACH DRAINAGE MESH TO CIP
CONCRETE WALL CORE WITH ADHESIVE, TYP.
S.S. TRUSS JOINT REINFORCEMENT
3/16" DIA. WIRE AND CROSS RODS, TYP.
3/8" TYPE N MORTAR JOINT, TYP.
1/2" TYPE N MORTAR JOINT
FLASHING AND DRIP EDGE, TYP.
WEEP VENT, TYP.
CUT INDIANA LIMESTONE CAP, TYP.
CONTINUOUS DRIP SLOT, ALL OVERHANGS, TYP.
BACKER ROD & SEALANT 3/8" JOINT, TYP.
LAYOUT LINE
REINFORCED CMU HALF BLOCK (NOM. 8 X 8 X 8)
GROUT SOLID, SEE STRUCTURAL TYP.
CMU HALF HEIGHT BLOCK (NOM.
8 X 4 X 8) GROUT SOLID, TYP.
WEEP VENT, TYP.
REINFORCED CAST-IN-PLACE
CONCRETE WALL; SEE
STRUCTURAL DRAWINGS
TOP OF PIER
CI710
CI710
CI711
CI711
CI714
6" MIN.
TYP.
5'-0"
LAYOUT POINT, TYP.
2'-0"
2' -0
113 16
.00
TYP.
6" 1'
-6
6" 1'-6"
FACE OF REINF. CONC.
FOUNDATION, SEE
STRUCTURAL
DRAWINGS, TYP.
LIMIT OF REINF. CONC.
FOOTING BELOW, SEE
STRUCTRUAL
DRAWINGS, TYP.
LAYOUT LINE, TYP.
5'-0"
LAYOUT POINT, TYP.
BRICK VENEER, TYP.
FACE OF WALL SHELF, TYP.
CAVITY W/ DRAINAGE
MESH, TYP.
3/8" TYPE N MORTAR JOINT, TYP.
LAYOUT LINE, TYP.
2'-0"
2' -0
113 16
6" 1'
-13 8"
6"
1'-6"
FACE OF REINF. CONC.
FOUNDATION, SEE
STRUCTURAL
DRAWINGS, TYP.
LIMIT OF REINF. CONC.
FOOTING BELOW, SEE
STRUCTRUAL
DRAWINGS, TYP.
45 8"
.00
TYP.
8" 1'-138"
1' -6
REINFORCED CMU HALF BLOCK (NOM. 8 X 8 X 8)
GROUT SOLID, SEE STRUCTURAL TYP.
FACE OF FOUNDATION BELOW, TYP.
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
FAYETTEVILLE, ARKANSAS
842CM3027
MAY 20, 2025 Dwg. of
Office of Design and Construction
Service U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
FAYETTEVILLE NATIONAL CEMETERY
COLUMBARIUM AND IN-GROUND
CREMAINS BURIAL EXPANSION
Fil e P ath
G:
\P
RO
J-2
4\2
_F
AY
ET
TE
VI
LL
E_
NA
TI
ON
AL
_C
EM
ET
ER
Y_
CO
LU
MB
AR
IU
M_
CR
EM
AI
NS
_E
XP
_F
CA
_R
EP
AI
RS
\20
3C
AD
\84
2C M3
7.0
.C I70
2.2
5.D W
G
CB Design Group
(601) 278-0966
Above Group
(321) 345-9026
05/20/25
Integrity Federal Services - The LA Group Joint Venture, LLC The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Aqua Engineering
(970) 372-6104
DBH JDB
CI710
COLUMBARIUM DETAILS 3
1" = 1'-0"
RETAINING WALL SECTION1 1'0 6"3" 1" = 1'-0"
TERMINUS PIER SECTION2 1'0 6"3"
1" = 1'-0"
TERMINUS PIER PLAN SECTION 14 1'0 6"3"
1" = 1'-0"
TERMINUS PIER PLAN SECTION 23 1'0 6"3"
5'-0"
LAYOUT POINT, TYP.
FACE OF FOUNDATION BELOW, TYP.
BRICK VENEER, TYP.
FACE OF WALL SHELF, TYP.
CAVITY W/ DRAINAGE
MESH, TYP.
3/8" TYPE N MORTAR JOINT, TYP.
LAYOUT LINE, TYP.
2'-0"
2' -0
113 16
6" 83 4"
6"
1'-6"
FACE OF REINF. CONC.
FOUNDATION, SEE
STRUCTURAL
DRAWINGS, TYP.
LIMIT OF REINF. CONC.
FOOTING BELOW, SEE
STRUCTRUAL
DRAWINGS, TYP.
45 8"
8" 83
4"
1' -6
REINFORCED CMU HALF BLOCK (NOM. 8 X 8 X 8)
GROUT SOLID, SEE STRUCTURAL TYP.
.00
TYP.
8"
45 8"
5'-0"
LAYOUT POINT, TYP.
FACE OF FOUNDATION BELOW, TYP.
BRICK VENEER, TYP.
3/8" TYPE N MORTAR JOINT, TYP.
LAYOUT LINE, TYP.
2'-0"
2' -0
113 16
FACE OF REINF. CONC.
FOUNDATION, SEE
STRUCTURAL
DRAWINGS, TYP.
LIMIT OF REINF. CONC.
FOOTING BELOW, SEE
STRUCTRUAL
DRAWINGS, TYP.
REINFORCED CMU HALF BLOCK (NOM. 8 X 8 X 8)
GROUT SOLID, SEE STRUCTURAL TYP.
90.00°TYP.
STONE CAP
BELOW, TYP.
CAP ARRIS
STONE CAP
ABOVE, TYP.
2'-918"
51 2" 1'
-6
113 16
51 2" 1'
-713 16
1' -3
3 16
1 8"
2' -1
5 16
2' -31 8"
4' -25 8"
FACE OF REINF. CONC.
FOUNDATION, SEE
STRUCTURAL
DRAWINGS, TYP.
LIMIT OF REINF. CONC.
FOOTING BELOW, SEE
STRUCTRUAL
DRAWINGS, TYP.
.00
TYP.
2' -1
1"
LAYOUT LINE, TYP.
EXTEND HORIZONTAL
REINFORCEMENT THROUGH
CONSTRUCTION JOINT, SEE
STRUCTURAL DRAWIGNS, TYP.
EXTEND HORIZONTAL
REINFORCEMENT
THROUGH
CONSTRUCTION
JOINT, SEE
STRUCTURAL
DRAWIGNS, TYP.
2'-918"
51 2" 1'
-6
113 16
1 8"
1' -3
3 16
1' -3
3 16
1 8"
2' -1
5 16
2' -31 8"
4' -25 8"
FACE OF REINF. CONC.
FOUNDATION, SEE
STRUCTURAL
DRAWINGS, TYP.
LIMIT OF REINF. CONC.
FOOTING BELOW, SEE
STRUCTRUAL
DRAWINGS, TYP.
.00
TYP.
1' -13 8"
FACE OF FOUNDATION BELOW, TYP.
BRICK VENEER, TYP.
FACE OF WALL SHELF, TYP.
CAVITY W/ DRAINAGE
MESH, TYP.
3/8" TYPE N MORTAR JOINT, TYP.
EDGE OF CONC. MOW STRIP, TYP. PIER BASE
STONE C (PIER
L4 STONE F)
2' -1
1"
45 8"
LAYOUT LINE, TYP.
EXTEND HORIZONTAL
REINFORCEMENT
THROUGH
CONSTRUCTION
JOINT, SEE
STRUCTURAL
DRAWIGNS, TYP.
2'-918"
51 2" 1'
-6
113 16
51 2" 1'
-3 3 16
1 8"
2' -1
5 16
2' -31 8"
4' -25 8"
FACE OF REINF. CONC.
FOUNDATION, SEE
STRUCTURAL
DRAWINGS, TYP.
LIMIT OF REINF. CONC.
FOOTING BELOW, SEE
STRUCTRUAL
DRAWINGS, TYP.
.00
TYP.
1' -13 8"
FACE OF FOUNDATION BELOW, TYP.
BRICK VENEER, TYP.
FACE OF WALL SHELF, TYP.
CAVITY W/ DRAINAGE
MESH, TYP.
3/8" TYPE N MORTAR JOINT, TYP.
EDGE OF CONC. MOW STRIP, TYP. PIER BASE
STONE BELOW
2' -1
1"
45 8"
LAYOUT LINE, TYP.
1' -3
3 16
2'-918"
51 2" 1'
-6
113 16
51 2" 1'
-3 3 16
1'
-3 3 16
1 8"
FACE OF REINF. CONC.
FOUNDATION, SEE
STRUCTURAL
DRAWINGS, TYP.
LIMIT OF REINF. CONC.
FOOTING BELOW, SEE
STRUCTRUAL
DRAWINGS, TYP.
1' -13 8"
FACE OF FOUNDATION BELOW, TYP.
BRICK VENEER, TYP.
FACE OF WALL SHELF, TYP.
CAVITY W/ DRAINAGE
MESH, TYP.
EDGE OF CONC.
MOW STRIP, TYP.
PIER BASE
STONE BELOW
.00
TYP.
1' -3
3 16
1 8"
8" PIER BASE
STONE, TYP.
2' -1
1"
45 8"
1'-11"
1' -5
45 8"
3/8" TYPE N MORTAR JOINT, TYP.
LAYOUT LINE, TYP.
7-5/8" X 3-1/2" X 1
2" THICK
WEEP VENT FOLDED IN
HALF TO FILL CAVITY.
BASIS OF DESIGN
MORTAR NET SOLUTIONSEDGE OF CONC.
PVMNT., TYP.
EXTEND HORIZONTAL REINFORCEMENT
THROUGH CONSTRUCTION JOINT, SEE
STRUCTURAL DRAWIGNS, TYP.
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
FAYETTEVILLE, ARKANSAS
842CM3027
MAY 20, 2025 Dwg. of
Office of Design and Construction
Service U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
FAYETTEVILLE NATIONAL CEMETERY
COLUMBARIUM AND IN-GROUND
CREMAINS BURIAL EXPANSION
Fil e P ath
G:
\P
RO
J-2
4\2
_F
AY
ET
TE
VI
LL
E_
NA
TI
ON
AL
_C
EM
ET
ER
Y_
CO
LU
MB
AR
IU
M_
CR
EM
AI
NS
_E
XP
_F
CA
_R
EP
AI
RS
\20
3C
AD
\84
2C M3
7.0
.C I70
2.2
5.D W
G
CB Design Group
(601) 278-0966
Above Group
(321) 345-9026
05/20/25
Integrity Federal Services - The LA Group Joint Venture, LLC The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Aqua Engineering
(970) 372-6104
DBH JDB
CI711
COLUMBARIUM DETAILS 4
1'0 6"3"1" = 1'-0"
TERMINUS PIER PLAN SECTION 32
1'0 6"3"1" = 1'-0"
TERMINUS PIER PLAN SECTION 41
1'0 6"3"1" = 1'-0"
COLUMBARIUM PIER TYPE L1 (SIM. M1; SIM. MIR. L4) PLAN SECTION 14
1'0 6"3"1" = 1'-0"
COLUMBARIUM PIER TYPE L1 (SIM. M1; SIM. MIR. L4) PLAN SECTION 23
1'0 6"3"1" = 1'-0"
COLUMBARIUM PIER TYPE L1 (SIM. M1; SIM. MIR. L4) PLAN SECTION 36
1'0 6"3"1" = 1'-0"
COLUMBARIUM PIER TYPE L1 (SIM. M1; SIM. MIR. L4) PLAN SECTION 45
2'-918"
51 2" 1'
-6
113 16
51 2" 1'
-3 3 16
1 8"
2' -31 8"
4' -25 8"
FACE OF REINF. CONC.
FOUNDATION (BELOW),
SEE STRUCTURAL
DRAWINGS, TYP.
LIMIT OF REINF. CONC.
FOOTING BELOW, SEE
STRUCTRUAL
DRAWINGS, TYP.
1' -13 8"
FACE OF FOUNDATION BELOW, TYP.
BRICK VENEER, TYP.
FACE OF WALL SHELF, TYP.
CAVITY W/ DRAINAGE
MESH, TYP.
3/8" TYPE N MORTAR JOINT, TYP.
EDGE OF CONC.
MOW STRIP, TYP.
PIER BASE
STONE BELOW
.00
TYP.
1' -3
3 16
1 8"
1' -1
11 2"
8"
PIER BASE STONE A
(PIER L4 STONE E)
2' -1
1"
PRECAST NICHE UNIT
55 16
97 8" 45 8"
1'-10"
1"
1' -5
45 8"
45 8" 83 4"
BACKER ROD
AND SEALANT
JOINT, TYP.
LAYOUT LINE, TYP.
EDGE OF CONC.
PVMNT., TYP.
PIER BASE STONE B
EXTEND HORIZONTAL REINFORCEMENT
THROUGH CONSTRUCTION JOINT, SEE
STRUCTURAL DRAWIGNS, TYP.
2'-918"
1 8"
1' -13 8"
113 16
1' -3
3 16
1 8"
2' -31 8"
4' -25 8"
FACE OF REINF. CONC.
FOUNDATION (BELOW),
SEE STRUCTURAL
DRAWINGS, TYP.
LIMIT OF REINF. CONC.
FOOTING BELOW, SEE
STRUCTRUAL
DRAWINGS, TYP.
FACE OF FOUNDATION BELOW, TYP.
BRICK VENEER, TYP.
FACE OF WALL SHELF, TYP.
CAVITY W/ DRAINAGE
MESH, TYP.
3/8" TYPE N MORTAR JOINT, TYP.
EDGE OF CONC. MOW STRIP, TYP. PIER BASE
STONE
BELOW, TYP.
.00
TYP.
1' -3
3 16
1 8"
1' -1
11 2"
8"
2' -1
1"
PRECAST NICHE UNIT
55 16
97 8" 1'-10"
1"
1' -5
BACKER ROD
AND SEALANT
JOINT, TYP.
STONE CAP
BELOW, TYP.
CAP ARRIS
RECESSED WELD PLATE, TYP.
EDGE OF CONC.
PVMNT., TYP.
ROW ID, TYP.
51 2"
45 8"
LAYOUT LINE, TYP.
.00
TYP.
FACE OF REINF. CONC.
FOUNDATION, SEE
STRUCTURAL
DRAWINGS, TYP.
LIMIT OF REINF. CONC.
FOOTING BELOW, SEE
STRUCTRUAL
DRAWINGS, TYP.
2'-758" 51 2"
1' -713 16
2' -1
5 16
1' -3
3 16
1 8"
2' -1
5 16
4' -25 8"
2' -1
1"
EXTEND HORIZONTAL
REINFORCEMENT THROUGH
CONSTRUCTION JOINT, SEE
STRUCTURAL DRAWIGNS, TYP.
LAYOUT LINE, TYP.
.00
TYP.
FACE OF REINF. CONC.
FOUNDATION, SEE
STRUCTURAL
DRAWINGS, TYP.
LIMIT OF REINF. CONC.
FOOTING BELOW, SEE
STRUCTRUAL
DRAWINGS, TYP.
2'-758"
51 2" 1'
-713 16
2' -1
5 16
1' -3
3 16
1 8"
2' -1
5 16
4' -25 8"
2' -1
1"
FACE OF FOUNDATION BELOW, TYP.
BRICK VENEER, TYP.
FACE OF WALL SHELF, TYP.
CAVITY W/ DRAINAGE
MESH, TYP.
3/8" TYPE N MORTAR JOINT, TYP.
EDGE OF CONC. MOW STRIP, TYP. PIER BASE
STONE D
45 8"
CONC. JOINT, SEE
STRUCTURAL
DRAWINGS, TYP.
1 8"
LAYOUT LINE, TYP.
.00
TYP.
FACE OF REINF. CONC.
FOUNDATION, SEE
STRUCTURAL
DRAWINGS, TYP.
LIMIT OF REINF. CONC.
FOOTING BELOW, SEE
STRUCTRUAL
DRAWINGS, TYP.
2'-758"
51 2" 1'
-713 16
2' -1
5 16
1' -3
3 16
1 8"
2' -1
5 16
4' -25 8"
2' -1
1"
FACE OF FOUNDATION BELOW, TYP.
BRICK VENEER, TYP.
FACE OF WALL SHELF, TYP.
CAVITY W/ DRAINAGE
MESH, TYP.
3/8" TYPE N MORTAR JOINT, TYP.
EDGE OF CONC. MOW STRIP, TYP.
45 8"
CONC. JOINT, SEE
STRUCTURAL
DRAWINGS, TYP.
PIER BASE
STONE BELOW
LAYOUT LINE, TYP.
FACE OF REINF. CONC.
FOUNDATION, SEE
STRUCTURAL
DRAWINGS, TYP.
LIMIT OF REINF. CONC.
FOOTING BELOW, SEE
STRUCTRUAL
DRAWINGS, TYP.
2'-758"
51 2" 1'
-713 16
2' -1
5 16
1' -3
3 16
1 8"
2' -1
5 16
4' -25 8"
2' -1
1"
FACE OF FOUNDATION BELOW, TYP.
BRICK VENEER, TYP.
FACE OF WALL SHELF, TYP.
CAVITY W/ DRAINAGE
MESH, TYP.
3/8" TYPE N MORTAR JOINT, TYP.
EDGE OF CONC. MOW STRIP, TYP. PIER BASE
STONE
BELOW
45 8"
.00
TYP.
7-5/8" X 3-1/2" X 1
2" THICK
WEEP VENT FOLDED IN
HALF TO FILL CAVITY, TYP.
BASIS OF DESIGN
MORTAR NET SOLUTIONS
CONC. JOINT, SEE
STRUCTURAL
DRAWINGS, TYP.
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
FAYETTEVILLE, ARKANSAS
842CM3027
MAY 20, 2025 Dwg. of
Office of Design and Construction
Service U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
FAYETTEVILLE NATIONAL CEMETERY
COLUMBARIUM AND IN-GROUND
CREMAINS BURIAL EXPANSION
Fil e P ath
G:
\P
RO
J-2
4\2
_F
AY
ET
TE
VI
LL
E_
NA
TI
ON
AL
_C
EM
ET
ER
Y_
CO
LU
MB
AR
IU
M_
CR
EM
AI
NS
_E
XP
_F
CA
_R
EP
AI
RS
\20
3C
AD
\84
2C M3
7.0
.C I70
2.2
5.D W
G
CB Design Group
(601) 278-0966
Above Group
(321) 345-9026
05/20/25
Integrity Federal Services - The LA Group Joint Venture, LLC The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Aqua Engineering
(970) 372-6104
DBH JDB
CI712
COLUMBARIUM DETAILS 5
1" = 1'-0"
COLUMBARIUM PIER TYPE L2 (SIM. L3, N2, N3, & N4; SIM. MIR. M2 & M3) PLAN SECTION 14
1'0 6"3"1" = 1'-0"
COLUMBARIUM PIER TYPE L1 (SIM. M1; SIM. MIR. L4) PLAN SECTION 61
1'0 6"3"1" = 1'-0"
COLUMBARIUM PIER TYPE L1 (SIM. M1; SIM. MIR. L4) PLAN SECTION 52 1'0 6"3"
1" = 1'-0"
COLUMBARIUM PIER TYPE L2 (SIM. L3, N2, N3, & N4; SIM. MIR. M2 & M3) PLAN SECTION 23 1'0 6"3"
1" = 1'-0"
COLUMBARIUM PIER TYPE L2 (SIM. L3, N2, N3, & N4; SIM. MIR. M2 & M3) PLAN SECTION 36 1'0 6"3"
COLUMBARIUM PIER TYPE L2 (SIM. L3, N2, N3, & N4; SIM. MIR. M2 & M3) PLAN SECTION 45 1'0 6"3"
2' -1
5 16
2' -1
5 16
FACE OF REINF. CONC.
FOUNDATION, SEE
STRUCTURAL
DRAWINGS, TYP.
LIMIT OF REINF. CONC.
FOOTING BELOW, SEE
STRUCTRUAL
DRAWINGS, TYP.
LAYOUT LINE, TYP.
2'-918"
51 2" 1'
-6
113 16
2' -1
5 16
2' -31 8"90
.00
TYP.
4' -25 8"
5'-0"
LAYOUT POINT, TYP.
FACE OF REINF.
CONC. FOUNDATION,
SEE STRUCTURAL
DRAWINGS, TYP.
LIMIT OF REINF. CONC.
FOOTING BELOW, SEE
STRUCTRUAL
DRAWINGS, TYP.
2'-758"
51 2" 1'
-713 16
2' -1
5 16
1' -3
3 16
1 8"
2' -1
5 16
4' -25 8"
2' -1
1"
FACE OF FOUNDATION BELOW, TYP.
FACE OF WALL SHELF, TYP.
CAVITY W/ DRAINAGE
MESH, TYP.
3/8" TYPE N MORTAR JOINT, TYP.
EDGE OF CONC. MOW STRIP, TYP. PIER BASE
STONE
45 8"
BACKER ROD
AND SEALANT
JOINT, TYP.
PRECAST NICHE UNIT, TYP.
LAYOUT LINE, TYP.
FACE OF REINF. CONC.
FOUNDATION (BELOW),
SEE STRUCTURAL
DRAWINGS, TYP.
55 16
97 8"
CONC. JOINT, SEE
STRUCTURAL
DRAWINGS, TYP.
.00
TYP.
PIER BASE
STONE D 1"
1" 1"
BRICK VENEER, TYP.
FACE OF REINF.
CONC.
FOUNDATION, SEE
STRUCTURAL
DRAWINGS, TYP.
LIMIT OF REINF.
CONC. FOOTING
BELOW, SEE
STRUCTRUAL
DRAWINGS, TYP.
2'-758"
51 2" 1'
-713 16
2' -1
5 16
1' -3
3 16
1 8"
2' -1
5 16
4' -25 8"
2' -1
1"
FACE OF FOUNDATION BELOW, TYP.
BRICK VENEER, TYP.
3/8" TYPE N MORTAR JOINT, TYP.
EDGE OF CONC. MOW STRIP, TYP. PIER BASE
STONE
45 8"
BACKER ROD
AND SEALANT
JOINT, TYP.
PRECAST NICHE UNIT, TYP.
LAYOUT LINE, TYP.
FACE OF REINF. CONC.
FOUNDATION (BELOW),
SEE STRUCTURAL
DRAWINGS, TYP.
55 16
97 8"
ROW ID, TYP.
RECESSED WELD PLATE, TYP.
CONC. JOINT, SEE
STRUCTURAL
DRAWINGS, TYP.
EDGE OF CONC.
PVMNT., TYP.
.00
TYP.
CAVITY W/ DRAINAGE
MESH, TYP.
FACE OF WALL SHELF, TYP.
1 8"
1' -3
3 16
1' -3
3 16
1 8"
2' -1
5 16
FACE OF REINF. CONC.
FOUNDATION, SEE
STRUCTURAL
DRAWINGS, TYP.
LIMIT OF REINF. CONC.
FOOTING BELOW, SEE
STRUCTRUAL
DRAWINGS, TYP.
.00
TYP.
1' -2
5 16
CAVITY W/ DRAINAGE
MESH, TYP.
3/8" TYPE N MORTAR
JOINT, TYP.
EDGE OF CONC.
MOW STRIP, TYP. PIER BASE
STONE
2' -1
1"
45 8"
LAYOUT LINE, TYP.
EDGE OF CONC.
PVMNT., TYP.
51 2"
7 8"
2' -1
5 16
2'-918"
8"
8"
5'-0"
LAYOUT POINT, TYP.
4' -25 8"
1 8"
1' -3
3 16
1 8"
2' -1
5 16
4' -25 8"
FACE OF REINF.
CONC. FOUNDATION,
SEE STRUCTURAL
DRAWINGS, TYP.
LIMIT OF REINF. CONC.
FOOTING BELOW, SEE
STRUCTRUAL
DRAWINGS, TYP.
1' -2
5 16
FACE OF FOUNDATION BELOW, TYP.
BRICK VENEER, TYP.
3/8" TYPE N MORTAR JOINT, TYP.
EDGE OF CONC.
MOW STRIP, TYP.
PIER BASE STONE H (PIER M4 & N5 STONE A)
2' -1
1"
45 8"
LAYOUT LINE, TYP.
EDGE OF
CONC.
PVMNT.,
TYP.
51 2"
7 8"
2' -1
5 16
2'-918"
8"
.00
TYP.
FACE OF WALL SHELF, TYP.
CAVITY W/ DRAINAGE
MESH, TYP.
7-5/8" X 3-1/2" X 1
2" THICK
WEEP VENT FOLDED IN
HALF TO FILL CAVITY.
BASIS OF DESIGN
MORTAR NET SOLUTIONS
5'-0"
LAYOUT POINT, TYP.
PIER
BASE
STONE,
TYP.
1' -3
3 16
1 8"
1' -3
3 16
1' -3
3 16
1 8"
2' -1
5 16
FACE OF REINF. CONC.
FOUNDATION, SEE
STRUCTURAL
DRAWINGS, TYP.
LIMIT OF REINF. CONC.
FOOTING BELOW, SEE
STRUCTRUAL
DRAWINGS, TYP.
1' -2
5 16
FACE OF FOUNDATION BELOW, TYP.
BRICK VENEER, TYP.
3/8" TYPE N MORTAR JOINT, TYP.
EDGE OF CONC.
MOW STRIP, TYP. PIER BASE
STONE BELOW
2' -1
1"
45 8"
LAYOUT LINE, TYP.
EDGE OF
CONC.
PVMNT.,
TYP.
51 2"
7 8"
2' -1
5 16
2'-918"
8"
.00
TYP.
FACE OF WALL SHELF, TYP.
CAVITY W/ DRAINAGE
MESH, TYP.
FACE OF REINF. CONC.
FOUNDATION (BELOW),
SEE STRUCTURAL
DRAWINGS, TYP.
PRECAST NICHE UNIT
PIER BASE STONE A
(PIER M4 & N5 STONE E)
BACKER ROD
AND SEALANT
JOINT, TYP.
5'-0"
LAYOUT POINT, TYP.
PIER BASE
STONE G
(PIER M4 &
N5 STONE I)
4' -25 8"
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
FAYETTEVILLE, ARKANSAS
842CM3027
MAY 20, 2025 Dwg. of
Office of Design and Construction
Service U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
FAYETTEVILLE NATIONAL CEMETERY
COLUMBARIUM AND IN-GROUND
CREMAINS BURIAL EXPANSION
Fil e P ath
G:
\P
RO
J-2
4\2
_F
AY
ET
TE
VI
LL
E_
NA
TI
ON
AL
_C
EM
ET
ER
Y_
CO
LU
MB
AR
IU
M_
CR
EM
AI
NS
_E
XP
_F
CA
_R
EP
AI
RS
\20
3C
AD
\84
2C M3
7.0
.C I70
2.2
5.D W
G
CB Design Group
(601) 278-0966
Above Group
(321) 345-9026
05/20/25
Integrity Federal Services - The LA Group Joint Venture, LLC The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Aqua Engineering
(970) 372-6104
DBH JDB
CI713
COLUMBARIUM DETAILS 6
1" = 1'-0"
COLUMBARIUM PIER TYPE N1 (SIM. MIR. M4 & N5) PLAN SECTION 141'0 6"3" 1'0 6"3"1" = 1'-0"
COLUMBARIUM PIER TYPE L2 (SIM. L3, N2, N3, & N4, SIM. MIR. M2 & M3) PLAN SECTION 52
1'0 6"3"1" = 1'-0"
COLUMBARIUM PIER TYPE L2 (SIM. L3, N2, N3, & N4, SIM. MIR. M2 & M3) PLAN SECTION 61 1" = 1'-0"
COLUMBARIUM PIER TYPE N1 (SIM. MIR. M4 & N5) PLAN SECTION 23 1'0 6"3"
1" = 1'-0"
COLUMBARIUM PIER TYPE N1 (SIM. MIR. M4 & N5) PLAN SECTION 36 1'0 6"3"
COLUMBARIUM PIER TYPE N1 (SIM. MIR. M4 & N5) PLAN SECTION 45 1'0 6"3"
1 8"
1 8"
2' -1
5 16
FACE OF REINF. CONC.
FOUNDATION, SEE
STRUCTURAL
DRAWINGS, TYP.
LIMIT OF REINF. CONC.
FOOTING BELOW, SEE
STRUCTRUAL
DRAWINGS, TYP.
1' -2
5 16
FACE OF FOUNDATION BELOW, TYP.
BRICK VENEER, TYP.
3/8" TYPE N MORTAR JOINT, TYP.
EDGE OF CONC.
MOW STRIP, TYP. PIER BASE
STONE BELOW
LAYOUT LINE, TYP.
EDGE OF CONC.
PVMNT., TYP.
51 2"
7 8"
2' -1
5 16
2'-918"
8"
.00
TYP.
FACE OF WALL SHELF, TYP.
CAVITY W/ DRAINAGE
MESH, TYP.
FACE OF REINF. CONC.
FOUNDATION (BELOW),
SEE STRUCTURAL
DRAWINGS, TYP.
PRECAST NICHE UNIT
PIER BASE STONE
BELOW, TYP.
BACKER ROD AND
SEALANT JOINT, TYP.
RECESSED WELD PLATE, TYP.
ROW ID, TYP.
2' -1
1"
45 8"
5'-0"
LAYOUT POINT, TYP.
1' -3
3 16
1' -3
3 16
4' -25 8"
CUSTOM INTEGRAL OPEN-MESH
DRAINAGE MAT (MORTAR NET) W/ WEEP
TABS FACTORY-BONDED TO 40-MIL
THERMOPLASTIC POLYOLEFIN (TPO)
FLASHING, STAINLESS STEEL (SS)
TERMINATION BAR, 14" HT. CORNER
BOOTS (TPO), AND CUSTOM CORNER
S.S. FLASHING, INSTALL PER
MANUFACTURER'S RECOMMENDATIONS,
TYP. BASIS OF DESIGN MORTAR NET
SOLUTIONS, TOTAL FLASH CAVITY WALL
DRAINAGE SOLUTION & COMPLETE
FLASH SYSTEMS.
S.S. DRIP EDGE, TYP.
S.S. TERMINATION BAR, 16 GAUGE,
WITH LIP, TYP.
WATER BLOCK MASTIC AND
SEALANT. BASIS OF DESIGN
BTL-1 SEALANT, TYP.
TYPE N MORTAR, TYP.
3/8" CONCAVE MORTAR JOINT, TYP.
MODULAR BRICK VENEER, TYP.
S.S. MASONRY ANCHOR 16"
O.C. MAX, VERT. & HOR., TYP.
PIER BEYOND, TYP.
AIR CAVITY WITH 1" EXTRUDED POLYMER
MATRIX DRAINAGE MESH HEAT
LAMINATED TO A PERMEABLE FILTER
FABRIC; BAISS OF DESIGN: CAV-AIR-ATOR
1.0 BY KEENE. ATTACH DRAINAGE MESH
TO CIP CONCRETE WALL CORE WITH
ADHESIVE, TYP.
DECORATIVE GRAVEL
(ROUNDED STONE), TYP.
FACE OF CONCRETE
FOUNDATION, SACK RUB
CONCRETE FINISH MINIMUM 6"
BELOW FINISH GRADE, TYP.
FINISH GRADE
COLUMN I.D.
SECTION
CORROSION
RESISTANT
COMPATIBLE METAL
OR BRONZE CASTING
THREADED STUDS
(3/16" X 1 1/2"). SET IN
5/16" DRILLED HOLES
WITH TYPE N
MORTAR
INSTALL FLUSH
AGAINST STONE
8"
8"
CORROSION
RESISTANT
COMPATIBLE METAL
OR BRONZE
CASTING THREADED
STUDS (3/16" X 1
1/2"). SET IN 5/16"
DRILLED HOLES
WITH TYPE N
MORTAR
INSTALL FLUSH
AGAINST BRICK 3
8"
8"
EQ
EQ
ROW I.D.
SECTION
COLUMN I.D.
ELEVATION
Ø3 1 4"
Ø3"
Ø212"
7/8" HT. NUMBERS
CAST WITH BASE;
FONT: OPTIMA
BOLD; CENTERED
ON FIELD
BRIGHT SATIN
FINISH RAISED
AREAS AND
BEVEL, TYP.
CHEMICALLY OXIDIZE
BACKGROUND TO
STATUARY MEDIUM
COLOR PEBBLE,
ANTIQUE FINISH
SOLID BRONZE CAST
OF LEAD-FREE TIN
BRONZE C900300
(NAVY 'G' BRONZE)
THREADED STUD
BEYOND, TYP.
ROW I.D.
ELEVATION
Ø21 8"
Ø2"
Ø134"
7/8" HT. LETTER
CAST WITH BASE;
FONT: OPTIMA
BOLD; CENTERED
ON FIELD
BRIGHT SATIN
FINISH RAISED
AREAS AND
BEVEL, TYP.
CHEMICALLY OXIDIZE
BACKGROUND TO
STATUARY MEDIUM
COLOR PEBBLE,
ANTIQUE FINISH
SOLID BRONZE CAST
OF LEAD-FREE TIN
BRONZE C900300
(NAVY 'G' BRONZE)
NOTE:
ADD CLEAR
PROTECTIVE
EXTERIOR
LACQUER TO ALL
BRONZE
SURFACES PRIOR
TO INSTALLATION.
THREADED STUD
BEYOND, TYP.
1'-334"
1' -03 4"
1"
8"
1 16
TY
P.
1"
8"
1'-1"
1" 3 8"
1 4"
3 8" 1"
ELEVATION
THREADED STUD
BEYOND. LOCATE
STUDS TO BE
CENTERED ON
RUNNING BOND
PATTERN MODULAR
BRICKS, TYP.
8" HT. LETTER CAST
WITH BASE; FONT:
OPTIMA BOLD;
CENTERED ON FIELD
BRIGHT SATIN FINISH
RAISED SURFACES
AND BEVEL, TYP.
CHEMICALLY OXIDIZE
BACKGROUND TO
STATUARY MEDIUM
COLOR PEBBLE,
ANTIQUE FINISH
SOLID BRONZE CAST
OF LEAD-FREE TIN
BRONZE C900300
(NAVY 'G' BRONZE)
NOTE:
ADD CLEAR PROTECTIVE
EXTERIOR LACQUER TO
ALL BRONZE SURFACES
PRIOR TO INSTALLATION.
8" 4" 4"
8" 37
8"
51 4" 51 4"
11 8" 11 8"
25 8" 25 8"
16"
8"
CORROSION
RESISTANT
COMPATIBLE
METAL OR
BRONZE
CASTING
THREADED
STUDS (3/16" X 1
1/2"). SET IN 5/16"
DRILLED HOLES
WITH TYPE N
MORTAR, TYP.
INSTALL FLUSH
AGAINST BRICK
BELOW BRICK
SOLDIER
COURSE
R 3 4 "
TYP.
8"
8"
3 8" 3 8"
1 16 " T
YP
SAWN BLANK
EDGE, TYP.
SMOOTH
FINISH, TYP.B
A
5 8"
11 2" 75 8"
11 2"
4" 11 2" 35
8"
2'-0"91 8"
2"
2'-918"
11 2"35 8"
11 2" 21 2"
11 2"
8"11
2" 11 2"1'-138"
PLAN SLOPE
ARROW, TYP.
SAWN BLANK
EDGE, TYP.
SMOOTH
FINISH, TYP.
BA
A
6"
11 2"
2'-918"
3" 1"
71 2"
ELEVATION BELEVATION A
B
71 2"
11 2" 2"
2" 35
8" 4" 11 2"
1058"
SMOOTH
FINISH,
TYP.
SECTION B
B
71 2"
11 2" 2"
8" 4" 11
2"
8"
SMOOTH
FINISH,
TYP.
SECTION A
B
71 2"
11 2" 2"
2" 35
8" 4" 11 2"
1058"
SMOOTH
FINISH,
TYP.
NOTE:
1. ALL CUT STONE ASSEMBLIES: INDIANA
LIMESTONE, COLOR GRAY, SELECT GRADE.
2. ALL EXPOSED TO VIEW STONE FACES TO
HAVE SMOOTH FINISH; SAWN FINISH TOP
AND BOTTOM
B
SMOOTH
FINISH,
TYP.
ELEVATION A
71 2"
11 2" 2"
8" 4"
2"91
8"
SAWN BLANK
EDGE, TYP.
SMOOTH
FINISH, TYP.
A
A
6"
11 2"
1'-334"
3" 1"
71 2"
ELEVATION B
SAWN BLANK
EDGE, TYP.
SMOOTH
FINISH, TYP.
B
A
91 8"
35 8" 11 2"
4"
1'-334"
PLAN
SLOPE
ARROW, TYP.
SECTION A
B
71 2"
11 2" 2"
8" 4"
2"91
8"
SMOOTH
FINISH,
TYP.
SAWN BLANK
EDGE, TYP.
SMOOTH
FINISH, TYP.B
A
91 8" 75 8" 11 2"
8"
2'-918"
35 8"
11 2" 21 2"
2"11
2" 75 8"1'-138"
PLAN SLOPE
ARROW, TYP.
4"
2"
SAWN BLANK
EDGE, TYP.
SMOOTH
FINISH, TYP.
BA
A
6"
11 2"
2'-918"
3"
1"
71 2"
ELEVATION B
2"
ELEVATION A
B
71 2"
11 2" 2"
8" 4" 11
2"
8"
SMOOTH
FINISH,
TYP.
SECTION B
B
71 2"
11 2" 2"
8" 4"
2"91
8"
SMOOTH
FINISH,
TYP.
SECTION A
B
71 2"
11 2" 2"
8" 4" 11
2"
8"
SMOOTH
FINISH,
TYP.
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
FAYETTEVILLE, ARKANSAS
842CM3027
MAY 20, 2025 Dwg. of
Office of Design and Construction
Service U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
FAYETTEVILLE NATIONAL CEMETERY
COLUMBARIUM AND IN-GROUND
CREMAINS BURIAL EXPANSION
Fil e P ath
G:
\P
RO
J-2
4\2
_F
AY
ET
TE
VI
LL
E_
NA
TI
ON
AL
_C
EM
ET
ER
Y_
CO
LU
MB
AR
IU
M_
CR
EM
AI
NS
_E
XP
_F
CA
_R
EP
AI
RS
\20
3C
AD
\84
2C M3
7.0
.C I70
2.2
5.D W
G
CB Design Group
(601) 278-0966
Above Group
(321) 345-9026
05/20/25
Integrity Federal Services - The LA Group Joint Venture, LLC The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Aqua Engineering
(970) 372-6104
DBH JDB
CI714
COLUMBARIUM DETAILS 7
1'0 6"3"1" = 1'-0"
COLUMBARIUM PIER TYPE N1 (SIM. MIR. M4 & N5) PLAN SECTION 51 0 4"1" 2"3" = 1'-0"
FLASHING AND DRIP EDGE SECTION ENLARGEMENT3
2"0 1"3" = 1'-0"
ROW / COLUMN IDENTIFICATION MEDALLIONS2 0 4"1" 2"3" = 1'-0"
WALL IDENTIFICATION PLAQUE4
8"0 4"2"1 1/2" = 1'-0"
PIER BASE STONE TYPE A5
8"0 4"2"1 1/2" = 1'-0"
PIER BASE STONE TYPE B6
8"0 4"2"1 1/2" = 1'-0"
PIER BASE STONE TYPE C7
AutoCAD SHX Text
AutoCAD SHX Text C
N
NOTE:
1. ALL CUT STONE ASSEMBLIES: INDIANA
LIMESTONE, COLOR GRAY, SELECT GRADE.
2. ALL EXPOSED TO VIEW STONE FACES TO
HAVE SMOOTH FINISH; SAWN FINISH TOP
AND BOTTOM
SAWN BLANK
EDGE, TYP.
SMOOTH
FINISH, TYP.
BA
A
6"
11 2"
2'-758"
3" 1"
71 2"
ELEVATION B
SAWN BLANK
EDGE, TYP.
SMOOTH
FINISH, TYP.B
A
91 8" 75 8" 11 2"
1'-438"75 8"
2'-758"
35 8"
11 2" 21 2"
2"
8"
1'-138"
PLAN SLOPE
ARROW, TYP.
2"
SAWN BLANK
EDGE, TYP.
SMOOTH
FINISH, TYP.
BA
A
6"
11 2"
2'-918"
3" 1"
71 2"
ELEVATION B
SAWN BLANK
EDGE, TYP.
SMOOTH
FINISH, TYP.B
A
2"11
2"35 8"
2'-0" 91 8"
2"
2'-918"
8" 11
2" 11 2"1'-138"
PLAN SLOPE
ARROW, TYP.
5 8"
11 2" 75 8"
11 2"
4" 35 8"
SECTION A
B
71 2"
11 2" 2"
2" 35
8" 4" 11 2"
1058"
SMOOTH
FINISH,
TYP.
SECTION B
B
71 2"
11 2" 2"
8" 4" 11
2"
8"
SMOOTH
FINISH,
TYP.
ELEVATION A
B
71 2"
11 2" 2"
2" 35
8" 4" 11 2"
1058"
SMOOTH
FINISH,
TYP.
ELEVATION A
B
71 2"
11 2" 2"
8" 4" 11
2"
8"
SMOOTH
FINISH,
TYP.
SECTION B
B
71 2"
11 2" 2"
8" 4"
2"91
8"
SMOOTH
FINISH,
TYP.
SECTION A
B
71 2"
11 2" 2"
8" 4" 11
2"
8"
SMOOTH
FINISH,
TYP.
ELEVATION A
B
71 2"
11 2" 2"
8" 4" 11
2"
8"
SMOOTH
FINISH,
TYP.
SECTION B
B
71 2"
11 2" 2"
8" 4"
2"91
8"
SMOOTH
FINISH,
TYP.
SECTION A
B
71 2"
11 2" 2"
8" 4" 11
2"
8"
SMOOTH
FINISH,
TYP.
SAWN BLANK
EDGE, TYP.
SMOOTH
FINISH, TYP.B
A
91 8" 75 8"
11 2"
8"
2"
35 8"
51 8"
21 2"
2'-918"
2" 75
8"1'-138"
PLAN SLOPE
ARROW, TYP.
4"
2"
SAWN BLANK
EDGE, TYP.
SMOOTH
FINISH, TYP.
BA
A
6"
11 2"
2'-918"
3"
1"
71 2"
ELEVATION B
2"
ELEVATION A
B
SMOOTH
FINISH,
TYP.
8"
2"
4"
7 8"11 2" 4"
2" 11 2"
71 2"
SECTION A
B
71 2"
11 2" 2"
8" 4"
2"91
8"
SMOOTH
FINISH,
TYP.
B
A
PLAN
91 8"
35 8" 11 2"
4"
2"
2'-618"
2'-458" SAWN BLANK
EDGE, TYP.
SMOOTH
FINISH, TYP.
SLOPE
ARROW, TYP.
A
A
ELEVATION B
11 2" 2"
1" 5 8"
11 2" 7 8"
71 2"
2'-618"
SAWN BLANK
EDGE, TYP.
SMOOTH
FINISH, TYP.
SAWN BLANK
EDGE, TYP.
SMOOTH
FINISH, TYP.
BA
A
6"
11 2"
2'-918"
3" 1"
71 2"
ELEVATION B
SAWN BLANK
EDGE, TYP.
SMOOTH
FINISH, TYP.B
A
8"
2'-0" 91 8"
2"
2'-918"
8" 11
2" 11 2"1'-138"
PLAN SLOPE
ARROW, TYP.
5 8"
11 2" 75 8"
11 2"
4" 35 8"
SECTION A
B
71 2"
11 2" 2"
2" 35
8" 4" 11 2"
1058"
SMOOTH
FINISH,
TYP.
SECTION B
B
71 2"
11 2" 2"
8" 4" 11
2"
1058"
SMOOTH
FINISH,
TYP.
2"
ELEVATION A
B
71 2"
11 2" 2"
2" 35
8" 4" 11 2"
1058"
SMOOTH
FINISH,
TYP.
ELEVATION A
B
SMOOTH
FINISH,
TYP.
8"
2"
4"
4" 2"
11 2" 71 2"
SECTION A
B
71 2"
11 2" 2"
8" 4"
2"
8"
SMOOTH
FINISH,
TYP.
B
A
PLAN
91 8"
35 8" 11 2"
4"
2'-458" SAWN BLANK
EDGE, TYP.
SMOOTH
FINISH, TYP.
SLOPE
ARROW, TYP.
A
A
ELEVATION B
11 2" 2"
1" 3"
71 2"
2'-458"
SAWN BLANK
EDGE, TYP.
SMOOTH
FINISH, TYP.
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
FAYETTEVILLE, ARKANSAS
842CM3027
MAY 20, 2025 Dwg. of
Office of Design and Construction
Service U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
FAYETTEVILLE NATIONAL CEMETERY
COLUMBARIUM AND IN-GROUND
CREMAINS BURIAL EXPANSION
Fil e P ath
G:
\P
RO
J-2
4\2
_F
AY
ET
TE
VI
LL
E_
NA
TI
ON
AL
_C
EM
ET
ER
Y_
CO
LU
MB
AR
IU
M_
CR
EM
AI
NS
_E
XP
_F
CA
_R
EP
AI
RS
\20
3C
AD
\84
2C M3
7.0
.C I70
2.2
5.D W
G
CB Design Group
(601) 278-0966
Above Group
(321) 345-9026
05/20/25
Integrity Federal Services - The LA Group Joint Venture, LLC The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Aqua Engineering
(970) 372-6104
DBH JDB
CI715
COLUMBARIUM DETAILS 8
8"0 4"2"1 1/2" = 1'-0"
PIER BASE STONE TYPE D1
8"0 4"2"1 1/2" = 1'-0"
PIER BASE STONE TYPE E2
8"0 4"2"1 1/2" = 1'-0"
PIER BASE STONE TYPE F3
1 1/2" = 1'-0"
PIER BASE STONE TYPE G4 8"0 4"2"
1 1/2" = 1'-0"
PIER BASE STONE TYPE H5 8"0 4"2"
1 1/2" = 1'-0"
PIER BASE STONE TYPE I6 8"0 4"2"
LIMESTONE, COLOR GRAY, SELECT GRADE.
2. ALL EXPOSED TO VIEW STONE FACES TO
HAVE SMOOTH FINISH; SAWN FINISH TOP
AND BOTTOM
BACKER ROD & SEALANT; CONTINUOUS AT
ALL EXPOSED JOINTS. SEALANT DEPTH
SHALL BE PER MANUFACTURER'S
RECOMMENDATIONS, TYP.
3/ 8"
3/
PLASTIC SHIMS; 4 LOCATIONS EACH
CAP. SHIMS SET A MINIMUM OF 3/4"
FROM EXPOSED EDGE OF PRECAST
NICHE UNIT
SURFACE OF CAULK TO BE CONCAVE
ENSURE CLEAN STRAIGHT LINE. RECOMMEND
USE OF PAINTERS TAPE 1/16" FROM EDGE AS A
TEMPORARY GUIDE. (USE AS RECOMMENDED BY
MANUFACTURER)
0'-3/4"
TAPE
TAPE
EXPOSED
EDGE OF
PRECAST
UNIT
EPDM 45 MIL. MEMBRANE OVER ENTIRE TOP
OF PRECAST UNITS AND PIERS. MAINTAIN
1/4" FROM EXPOSED EDGE OF PRECAST UNIT
WALL LAYOUT LINE
BACKER ROD & SEALANT; CONTINUOUS AT
ALL EXPOSED JOINTS, SEALANT JOINT
DEPTH SHALL BE PER MANUFACTURER'S
RECOMMENDATIONS, TYP.
PLASTIC SHIMS; 4 LOCATIONS EACH CAP.
CENTER SHIMS OVER PRECAST NICHE
UNITS VERTICAL WEBS.
FACE OF CAP
FACE OF PIER BEYOND
PRECAST COLUMBARIUM
NICHE UNIT
FIELD-DRILLED HOLE TO
ACCEPT S.S. PINS
(AFTER CAPS ARE SET);
(2) PINS PER CAP; PIN IS
LOOSE-FIT IN CAP; PLUG
HOLE END W/ HYDRAULIC
CEMENT, FLUSH
W/PRECAST NICHE UNIT
SURFACE. HOLES SHALL
BE NOT GREATER THAN
1/8" IN DIAMETER THAN
PIN. COAT INSIDE OF
NICHE WITH
CEMENTITIOUS COATING
FOR UNIFORM
APPEARANCE (BASIS OF
DESIGN ALLEGRO II).
RECESSED S.S. WELD PLATES
EPDM MEMBRANE (45 MIL)
OVER ENTIRE TOP OF PRECAST
NICHE UNITS & PIERS, TYP.
NICHE COVER
ATTACHMENT, TYP.
CONTINUOUS DRIP SLOT
RECESSED WELD PLATES, TYP.
TOP OF PRE-CAST
COLUMBARIUM NICHE UNIT,
TYP.
NICHE COVER; PROTECT FROM
CONSTRUCTION, TYP.
CAP SHIMS (4) FOUR MIN. PER
CAP, TYP.
CAP ABOVE, TYP.
VERTICAL COLUMBARIUM
UNIT JOINT, TYP.
3/8" BACKER ROD AND SEALANT
CAP JOINT ABOVE, CENTERED
ON OF NICHE WEBBING, TYP.
NICHE WEBBING BELOW, TYP.
NOTES:
THOROUGHLY CLEAN TOP OF
PRECAST NICHE UNITS.
PROVIDE SHIMS AND MORTAR
AT MAXIMUM SPACING SHOWN
REGARDLESS OF WHETHER
THE SUBSTRATE BELOW IS
PRECAST NICHE OR PIERS
EPDM MEMBRANE (45 MIL)
OVER ENTIRE TOP OF
PRECAST UNITS & PIERS.
EXCESS MATERIAL AT CIP
CONCRETE TO EXTEND DOWN
VERTICAL SURFACES. TRIM
EPDM MEMBRANE 1/4" AWAY
FROM VERTICAL FACE OF
EXPOSED PRECAST NICHE
UNIT, TYP.
TWO (2) PINS PER CAP. FIELD
DRILLED HOLE TO RECEIVE
S.S. PIN (PINS THROUGH
PRECAST NICHE UNITS
DRILLED AFTER CAPS HAVE
BEEN SET); TYP.
SEALANT JOINT WITH
BACKER ROD BETWEEN
PRECAST NICHE UNITS
AND CIP CONC CORE, TYP.
BLOB OF TYPE N MORTAR TO
PROVIDE INTERMEDIATE
SUPPORT OF CAPS BETWEEN
SHIMS; LOCATED ABOVE
VERTICAL WEB OF PRECAST
UNIT BELOW; MAXIMUM
SPACING OF CAP SUPPORT
(SHIMS OR MORTAR) SHALL BE
1'-0" MAX.
10" TYP.
EDGE OF PAVEMENT
FACE OF CONCRETE
FOUNDATION BELOW
13 4" M
AX
TY
P.
3"
CLR.
MIN.
3/8"
3 8"
O F
NI
CH
E W
EB
CAP
3/4" WIDE SAWN-CUT
WEEP VENT CENTERED ON
CAP JOINT ENSURE CLEAN
STRAIGHT EDGES PER
APPROVED MOCKUP.
BACKER ROD AND SEALANT
AT ALL EXPOSED JOINT, TYP.
BEHIND WEEP VENT, PLASTIC SHIMS; 4
LOCATIONS EACH CAP MIN.; ALL SHIMS TO
OCCUR OVER FULL, UNJOINTED PRECAST
COLUMBARIUM WEB CAULK CONTINUOUS
UP TO WEEP VENT,
TYP.
PRECAST COLUMBARIUM
VERTICAL WEB
ENSURE CLEAN STRAIGHT LINE.
RECOMMEND USE OF PAINTERS TAPE
1/16" AS A TEMPORARY GUIDE (USE AS
RECOMMENDED BY MANUFACTURER)SURFACE OF
CAULK TO BE
FLUSH
BACKER ROD AT
CAP OVERHANG
NICHE COVER ATTACHMENT
ALIGN CENTER LINE OF CAP JOINT WITH
CENTER LINE OF PRE-CAST CONC.
COLUMBARIUM UNIT NICHE WEB OR ALLIGN
CENTER LINE OF CAP JOINT WITH CENTER LINE
OF COLUMBARIUM UNIT NICHE JOINT.
TAPE, TYP.
TEMP. PAINTER'S TAPE TO CREATE
UNIFORM JOINT APPEARANCE
NOTES:
1. ALIGN VERTICAL JOINTS WITH VERTICAL CAP STONE JOINTS. JOINTS SHALL BE CENTERED ON CENTERLINE
OF NICHE WEB. WEEP VENTS SHALL BE PLACED AT EACH VERTICAL CAP JOINT.
2. ALL JOINTS SHALL BE CLEAN & PRIMED PRIOR TO APPLYING SEALANT. APPLY APPROVED JOINT PRIMER
IMMEDIATELY PRIOR TO SEALANT APPLICATION FOLLOWING CLEANING WHICH IS TO BE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. DEPTH OF SEALANT SHALL BE EQUAL TO WIDTH OF JOINT
±1/16" TYP. MANUFACTURER'S RECOMMENDATIONS GOVERN. BACKER ROD NOT MEETING THIS
TOLERANCE SHALL BE REMOVED AND RESET BEFORE APPLYING SEALANT.
EPDM MEMBRANE (45
MIL) OVER ENTIRE
TOP OF PRECAST
UNITS & PIERS
CI716
C L
CL
16"
4'-09 16"
2' -313 16
2'
-313 16
4' -75 8"
2' -0
2'
-0
WASH
W
AS
H W
AS
H
W
AS
H W
AS
H
ARRIS
LINE, TYP.
CONTINUOUS
DRIP SLOT,
TYP.
EDGE OF CAP
BELOW, TYP.
CI716
3'-358"
2' -0
2'
-0
4' -0
W
AS
H W
AS
H
CI716
2'-1158"
ARRIS
LINE, TYP.
CONTINUOUS
DRIP SLOT,
TYP.
EDGE OF CAP
BELOW, TYP.
2' -0
2'
-0
4' -0
W
AS
H W
AS
H
CI716
4'-09 16"
ARRIS
LINE, TYP.
CONTINUOUS
DRIP SLOT,
TYP.
EDGE OF CAP
BELOW, TYP.
2' -0
2'
-0
4' -0
313 16
2' -313 16
2'
-313 16
4' -75 8"
16"
1'-713 16" 1'-713
16"
16"
W
AS
H W
AS
H
CI716
3'-358"
4'-912"
W
AS
H W
AS
H
W
AS
H W
AS
H
ARRIS
LINE, TYP.
CONTINUOUS
DRIP SLOT,
TYP.
EDGE OF CAP
BELOW, TYP.
2' -0
2'
-0
4' -0
W
AS
H W
AS
H
CI716
ARRIS
LINE, TYP.
CONTINUOUS
DRIP SLOT,
TYP.
EDGE OF CAP
BELOW, TYP.
3'-1158"
2' -0
2'
-0
4' -0
W
AS
H W
AS
H
CI716
ARRIS
LINE, TYP.
CONTINUOUS
DRIP SLOT,
TYP.
EDGE OF CAP
BELOW, TYP.
3'-09 16"
2'-313 16" 2'-313
16"
5" 1"
3"
9"
4'-758"
CONTINUOUS DRIP SLOT, TYP.
2'-0" 2'-0" 4'-0"
5" 3"
1" 9"
CONTINUOUS DRIP SLOT, TYP.
1'-1" 1'-1" 2'-2"
3" 2"
1"6"
CONTINUOUS DRIP SLOT, TYP.
1"
1"1" 2"
3 8"
4"
8"1
8"
EDGE OF CAP
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
FAYETTEVILLE, ARKANSAS
842CM3027
MAY 20, 2025 Dwg. of
Office of Design and Construction
Service U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
FAYETTEVILLE NATIONAL CEMETERY
COLUMBARIUM AND IN-GROUND
CREMAINS BURIAL EXPANSION
Fil e P ath
G:
\P
RO
J-2
4\2
_F
AY
ET
TE
VI
LL
E_
NA
TI
ON
AL
_C
EM
ET
ER
Y_
CO
LU
MB
AR
IU
M_
CR
EM
AI
NS
_E
XP
_F
CA
_R
EP
AI
RS
\20
3C
AD
\84
2C M3
7.0
.C I70
2.2
5.D W
G
CB Design Group
(601) 278-0966
Above Group
(321) 345-9026
05/20/25
Integrity Federal Services - The LA Group Joint Venture, LLC The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Aqua Engineering
(970) 372-6104
DBH JDB
CI716
COLUMBARIUM DETAILS 9
1'0 6"3"1" = 1'-0"
COLUMBARIUM CAP SETTING PLAN ENLARGEMENT5 0 4"1" 2"3" = 1'-0"
COLUMBARIUM CAP SETTING SECTION ENLARGEMENT7
6" = 1'-0"
COLUMBARIUM CAP SETTING ELEVATION ENLARGEMENT 6 8"0 4"2"
1"…