This document is a comprehensive 305-page Signage Design Manual (PG 18-10) dated May 16, 2023, specifically for the Department of Veterans Affairs (VA), detailing interior and exterior signage standards and design specifications. The manual provides extensive technical guidance for various sign types, including interior wall directional signs, floor level directional signs, ceiling mounted directional signs, exterior monument signs, building identification signs, and specialty signs with precise dimensional, graphic, and installation requirements.

The manual covers sign design parameters such as typography (predominantly Helvetica Bold), color specifications, mounting instructions, and recommended placement heights for different sign types. It includes detailed drawings and layouts for signs ranging from small 6" high by 9" wide interior signs to large 14'-6" high exterior monument signs, with variations for illuminated and non-illuminated signage. The document appears closely related to the referenced federal contract opportunity (Solicitation Number: 36C26325B0011) for "Update Signage & Wayfinding" within the Veterans Health Administration's Veterans Integrated Service Network 23, suggesting this manual could serve as a key reference document for the solicitation.

View the file

Other files for this federal contract opportunity

Other files attached to 636A8-23-101, Update Signage & Wayfinding, newest first.
File Type Posted
S06 Atch H Revised JA for Over SAT_Redacted - 3 pages.pdf PDF
S06 Atch C.2 Revised Drawings - 26 pages.pdf PDF
S06 Atch C.1 Revised Drawings - 34 pages.pdf PDF
S06 36C26325B0011 - Amendment 0004.pdf PDF
S06 Specification Section 32 17 23 Pavement Markings - 5 pages.pdf PDF
S06 Atch B Revised Specs - 202 pages.pdf PDF
S06 Late Questions and Responses - Solicitation 36C26325B0011 - 3 pages.pdf PDF
S06 Addendum Number 1 - 1 page.pdf PDF
S06 Questions and Responses - Solicitation 36C26325B0011 - 8 pages.pdf PDF
S06 36C26325B0011 - Amendment 0003.pdf PDF
S06 36C26325B0011 - Amendment 0002.pdf PDF
S06 Pre-Bid Site Visit Sign-In - 2 pages.pdf PDF
S06 Pre-Bid Site Visit Agenda - 2 pages.pdf PDF
S06 36C26325B0011 - Amendment 0001.pdf PDF
S02 Atch G VA6500 Appendix C 1 - 1 page.pdf PDF
S02 Atch C.2 Drawings - 26 pages.pdf PDF
S02 Atch F Wage Determination IA20250068 4-4-2025 - 7 pages.pdf PDF
S02 Atch D VAAR 852.219-75 Limitations on Subcontracting Cert of Compliance - 2 pages.pdf PDF
S02 Atch A.3 SOW Atch 2 TMS 20939 - 4 pages.pdf PDF
S02 Atch A.2 SOW Atch 1.1 PG 18-10 Signage Design Manual Part 1 - 305 pages.pdf PDF
S02 Atch H JA for Over SAT_Redacted - 3 pages_Redacted.pdf PDF
S02 Atch E Safety or Environmental Violations and EMR Information - 2 pages.pdf PDF
S02 Atch A.4 SOW Atch 3 NARA RM Contract Language - 3 pages.pdf PDF
S02 Atch A.2 SOW Atch 1.3 PG 18-10 Signage Design Manual Part 3 - 305 pages.pdf PDF
S02 Atch A.1 SOW - 4 pages.pdf PDF
S02 Atch C.1 Drawings - 34 pages.pdf PDF
S02 Atch B Specs - 240 pages.pdf PDF
S02 36C26325B0011.pdf PDF
Show all 28

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PG 18-10 Signage Design Manual May 16, 2023

IN-14.06-.07 Interior Signage Drawings Wall Directional – Single Insert

1/2" (12.7 mm)

1/2" (12.7 mm) 1/2" (12.7 mm)

1/2" (12.7 mm) 1/2" (12.7 mm)

1" (25.4 mm)

1/2" (12.7 mm) 1/2" (12.7 mm)

1" (25.4 mm)

1/2" (12.7 mm) 1/2" (12.7 mm)

1" (25.4 mm)

1/2" (12.7 mm) 1/2" (12.7 mm)

1" (25.4 mm)

1" (25.4 mm)

1" (25.4 mm)

1" (25.4 mm)

2" (50.8 mm)

3/4" (19.05 mm)

17" (431.8 mm)

3" (76.2 mm)

11" (279.4 mm)

3" (76.2 mm)

3" (76.2 mm)

11" (279.4 mm)

1/2" (12.7 mm)

1/2" (12.7 mm) 1/2" (12.7 mm)

1/2" (12.7 mm) 1/2" (12.7 mm)

1" (25.4 mm)

1/2" (12.7 mm) 1/2" (12.7 mm)

1" (25.4 mm)

1/2" (12.7 mm) 1/2" (12.7 mm)

1" (25.4 mm)

1/2" (12.7 mm) 1/2" (12.7 mm)

1" (25.4 mm)

1" (25.4 mm)

1" (25.4 mm)

1" (25.4 mm)

1/2" (12.7 mm)

1" (25.4 mm)

1" (25.4 mm)

1" (25.4 mm)

2" (50.8 mm)

3/4" (19.05 mm)

17" (431.8 mm)

5/8" (15.875 mm) - 3/4" (19.05 mm) IN-14.06

IN-14.07

Sign Profile

Section 3.1 306

Interior Signage Drawings

Wall Directional – Dual Inserts

IN-14.08

25" High x 17" Wide (635 mm H x 431.8 mm W)

IN-14.10

28" High x 17" Wide (711.2 mm H x

431.8 mm W)

IN-14.10

28" High x 17" Wide (711.2 mm H x

431.8 mm W)

IN-14.11

31" High x 17" Wide (787.4 mm H x

431.8 mm W)

Section 3.1 307

Description & Use These signs are used to display extended directional information on walls where more than five lines of copy are needed. Sign has permanent headers and/or footers and two easily updatable message inserts that accepts standard tabloid paper size.

Message Configuration Refer to message layout drawing for dimensions.

Rule lines are printed on insert to visually separate messages.

IN-14.08: Header with directional arrow and two updatable inserts with five lines of copy each IN-14.09: Two headers with directional arrows and two updatable inserts with five lines of copy each IN-14.10: Header with directional arrow, two updatable inserts with five lines of copy each, and footer with additional wayfinding information IN-14.11: Two headers with directional arrows, two updatable inserts with five lines of copy each, and footer with additional wayfinding information

Sign Components Component based sign system

Graphic Process Header: Direct second surface digital print or silk-screened.

Message Insert: Paper or acetate sheet with digital print.

Colors Refer to the color chart in the Appendix.

Typography Helvetica Bold

Installation Mount at 60" (1524 mm) above finished floor to the center of the sign.

Recommendations Keep directional messages simple, providing only information necessary to decide at that specific location.

Use consistent terminology throughout the facility, online, and on appointment letters.

Refer to the VHA Standardized Nomenclature document for a list of approved department names.

IN-14.08-.11

IN-14.08-.11 Interior Signage Drawings Wall Directional – Dual Inserts

Message Layout

Section 3.1 308

- -IN-14.12-.13

PG 18-10 Signage Design Manual

Size IN-14.12: 24" High x 24" Wide (609.6 mm H x 609.6 mm W)

IN-14.13: 28" High x 24" Wide (711.2 mm H x 609.6 mm W)

Description & Use These signs are used to display directional information on walls in areas where larger copy is needed for greater viewing distance. Sign has permanent header and/or footer and easily updatable message insert.

Message Configuration Refer to message layout drawing for dimensions.

Rule lines are printed on insert to visually separate messages.

IN-14.12: Header with directional arrow and updatable insert with six lines of copy

IN-14.13: Adds an optional footer for additional wayfinding information like building/floor number or wing/zone name.

Sign Components Component based sign system

Graphic Process Header: Direct second surface digital print or silk-screened.

Message Insert: Paper or acetate sheet with digital print.

Colors Refer to the color chart in the Appendix.

Typography Helvetica Bold

Installation Mount at 60" (1524 mm) above finished floor to the center of the sign.

Recommendations These signs can be paired side by side (not stacked) for multi directional information.

Keep directional messages simple, providing only information necessary to decide at that specific location. Use consistent terminology throughout the facility, online, and on appointment letters.

Refer to the VHA Standardized Nomenclature document for a list of approved department names.

Interior Signage Drawings May 16, 2023

Wall Directional – Oversized Insert

IN-14.12 IN-14.13

Mounting Concealed mechanical fasteners.

Section 3.1 309

IN-14.12-.13 Interior Signage Drawings Wall Directional – Oversized Inserts

Message Layout

Section 3.1 310

311 Section 3.1

IN-14.14-.17 Interior Signage Drawings

IN-14.14

Floor Level Directional – Permanent Panel Size IN-14.14: 22" High x 20" Wide (558.8 mm H x 508 mm W)

IN-14.15: 28" High x 20" Wide (711.2 mm H x 508 mm W)

IN-14.16: 34" High x 20" Wide (863.6 mm H x 508 mm W)

IN-14.17: 40" High x 20" Wide (1016 mm H x 508 mm W)

Description & Use These signs are used to display directional information and current level number at elevator lobbies where there are no other forms of level identification. Sign has removeable component panels with permanent messages.

Message Configuration Refer to message layout drawing for dimensions.

Sign Components This component-based sign system has removeable component panels with permanent messages.

A single sign system and standard should be used throughout the facility. Avoid simultaneously using panel-based systems and insert based directional signs within the same facility.

Graphic Process Direct digital print or silk-screened.

Colors Refer to the color chart in the Appendix.

Typography Helvetica Bold

Installation Mount at 60" (1524 mm) above finished floor to the center of the sign.

Recommendations Keep directional messages simple, providing only information necessary to decide at that specific location. List destinations in alphanumeric order and limit the number per sign.

Use consistent terminology throughout the facility, online, and on appointment letters.

Refer to the VHA Standardized Nomenclature document for a list of approved department names.

IN-14.15 IN-14.16 IN-14.17

Mounting Concealed mechanical fasteners.

IN-14.14-.17 Interior Signage Drawings Floor Level Directional – Permanent Panel

IN-14.14 IN-14.15

IN-14.16

IN-14.17

Typical Arrow and Text

Section 3.1 312

-IN-14.18

Size Sign Face:

28" High x 17" Wide (711.2 mm H x 431.8 mm W)

Description & Use These signs are used to display directional information and current level number at elevator lobbies where there are no other forms of level identification. Sign has permanent header and easily updatable message insert that accepts standard tabloid paper size.

Message Configuration Refer to message layout drawing for dimensions.

Rule lines are printed on insert to visually separate messages.

Sign Components Component based sign system

See Section 2.1 for applicable component sign system styles.

Graphic Process Header: Direct second surface digital print or silk-screened

Message Insert: Paper or acetate sheet with digital print

Colors Refer to the color chart in the Appendix.

Typography Helvetica Bold

Mounting Concealed mechanical fasteners

Installation Mount at 60" (1524 mm) above finished floor to the center of the sign.

Recommendations Keep directional messages simple, providing only information necessary to decide at that specific location. List destinations in alphanumeric order and limit the number per sign.

Use consistent terminology throughout the facility, online, and on appointment letters.

Refer to the VHA Standardized Nomenclature document for a list of approved department names.

May 16, 2023

Interior Signage Drawings Floor Level Directional – Dual Inserts

Section 3.1 313

IN-14.18 Interior Signage Drawings Floor Level Directional – Dual Inserts

Message Layout

Section 3.1 314

315 Section 3.1

IN-15.51/.55 Interior Signage Drawings Ceiling Mounted Directional and Department ID

Size Sign Face:

6" High x 40" Wide (152.4 mm H x 1016 mm W)

Description & Use Ceiling-mounted sign for directional and department identification information. Can be single or double-sided.

Message Configuration Refer to message layout drawings for dimensions.

Sign Components Varies by component sign system:

Component Strips, Flat Insert or J-Track Insert-Based Sign Systems.

Graphic Process Applied vinyl for semi-permanent messages or digitally printed insert for updatable messages.

Colors Refer to the color chart in the Appendix.

Typography Helvetica Bold

Mounting Suspended from ceiling with braided stainless steel cable.

Installation Mount at minimum 80" (2032 mm) above finished flooring to the bottom of the sign.

See Section 2.1 for installation details.

Recommendations Keep directional messages simple, providing only information necessary to decide at that specific location. List destinations in alphanumeric order and limit the number per sign.

Use consistent terminology throughout the facility, online, and on appointment letters.

Refer to the VHA Standardized Nomenclature document for a list of approved department names.

Inserts should follow an approved template established as part of the facility's sign standard and wayfinding plan. Ideally, all message updates should be documented and managed by a designated staff member or department such as Interior Design.

Message Layout A

Message Layout B

Message Layout C

IN-15.51/.55 Interior Signage Drawings Ceiling Mounted Directional and Department ID

Message Layout A

Message Layout B

Section 3.1 316

317 Section 3.1

IN-15.52/.56 Interior Signage Drawings Ceiling Mounted Directional and Department ID

Size Sign Face:

12" High x 40" Wide (304.8 mm H x 1016 mm W)

Description & Use Ceiling-mounted sign for directional and department identification information. Can be single or double-sided.

Message Configuration Refer to message layout drawings for dimensions.

Sign Components Varies by component sign system:

Component Strips, Flat Insert or J-Track Insert-Based Sign Systems.

Graphic Process Applied vinyl for semi-permanent messages or digitally printed insert for updatable messages.

Colors Refer to the color chart in the Appendix.

Typography Helvetica Bold

Mounting Suspended from ceiling with braided stainless steel cable.

Installation Mount at minimum 80" (2032 mm) above finished flooring to the bottom of the sign.

See Section 2.1 for installation details.

Recommendations Keep directional messages simple, providing only information necessary to decide at that specific location. List destinations in alphanumeric order and limit the number per sign.

Use consistent terminology throughout the facility, online, and on appointment letters.

Refer to the VHA Standardized Nomenclature document for a list of approved department names.

Inserts should follow an approved template established as part of the facility's sign standard and wayfinding plan. Ideally, all message updates should be documented and managed by a designated staff member or department such as Interior Design.

Message Layout A Message Layout B

Message Layout C Message Layout D

IN-15.52/.56 Interior Signage Drawings Ceiling Mounted Directional and Department ID

Message Layout A

Message Layout B

Message Layout C

Message Layout D

Section 3.1 318

319 Section 3.1

IN-15.61/.65 Interior Signage Drawings Ceiling Mounted Directional and Department ID

Size Sign Face:

6" High x 60" Wide (152.4 mm H x 1524 mm W)

Description & Use Ceiling-mounted sign for directional and department identification information. Can be single or double-sided.

Message Configuration Refer to message layout drawings for dimensions.

Sign Components Varies by component sign system:

Component Strips, Flat Insert or J-Track Insert-Based Sign Systems.

Graphic Process Applied vinyl for semi-permanent messages or digitally printed insert for updatable messages.

Colors Refer to the color chart in the Appendix.

Typography Helvetica Bold

Mounting Suspended from ceiling with braided stainless steel cable.

Installation Mount at minimum 80" (2032 mm) above finished flooring to the bottom of the sign.

See Section 2.1 for installation details.

Recommendations Keep directional messages simple, providing only information necessary to decide at that specific location. List destinations in alphanumeric order and limit the number per sign.

Use consistent terminology throughout the facility, online, and on appointment letters.

Refer to the VHA Standardized Nomenclature document for a list of approved department names.

Inserts should follow an approved template established as part of the facility's sign standard and wayfinding plan. Ideally, all message updates should be documented and managed by a designated staff member or department such as Interior Design.

Message Layout A

IN-15.61/.65 Interior Signage Drawings Ceiling Mounted Directional and Department ID

Message Layout A

Message Layout B

Section 3.1 320

321 Section 3.1

IN-15.62/.66 Interior Signage Drawings Ceiling Mounted Directional and Department ID

Size Sign Face:

12" High x 60" Wide (304.8 mm H x 1524 mm W)

Description & Use Ceiling-mounted sign for directional and department identification information. Can be single or double-sided.

Message Configuration Refer to message layout drawings for dimensions.

Sign Components Varies by component sign system:

Component Strips, Flat Insert or J-Track Insert-Based Sign Systems.

Graphic Process Applied vinyl for semi-permanent messages or digitally printed insert for updatable messages.

Colors Refer to the color chart in the Appendix.

Typography Helvetica Bold

Mounting Suspended from ceiling with braided stainless steel cable.

Installation Mount at minimum 80" (2032 mm) above finished flooring to the bottom of the sign.

See Section 2.1 for installation details.

Recommendations Keep directional messages simple, providing only information necessary to decide at that specific location. List destinations in alphanumeric order and limit the number per sign.

Use consistent terminology throughout the facility, online, and on appointment letters.

Refer to the VHA Standardized Nomenclature document for a list of approved department names.

Inserts should follow an approved template established as part of the facility's sign standard and wayfinding plan. Ideally, all message updates should be documented and managed by a designated staff member or department such as Interior Design.

Message Layout A

IN-15.62/.66 Interior Signage Drawings Ceiling Mounted Directional and Department ID

Message Layout A

Message Layout B

Section 3.1 322

323 Section 3.1

IN-15.71/.75 Interior Signage Drawings Ceiling Mounted Directional and Department ID

Size Sign Face:

6" High x 80" Wide (152.4 mm H x 2032 mm W)

Description & Use Ceiling-mounted sign for directional and department identification information. Can be single or double-sided.

Message Configuration Refer to message layout drawings for dimensions.

Sign Components Varies by component sign system:

Component Strips, Flat Insert or J-Track Insert-Based Sign Systems.

Graphic Process Applied vinyl for semi-permanent messages or digitally printed insert for updatable messages.

Colors Refer to the color chart in the Appendix.

Typography Helvetica Bold

Mounting Suspended from ceiling with braided stainless steel cable.

Installation Mount at minimum 80" (2032 mm) above finished flooring to the bottom of the sign.

See Section 2.1 for installation details.

Recommendations Keep directional messages simple, providing only information necessary to decide at that specific location. List destinations in alphanumeric order and limit the number per sign.

Use consistent terminology throughout the facility, online, and on appointment letters.

Refer to the VHA Standardized Nomenclature document for a list of approved department names.

Inserts should follow an approved template established as part of the facility's sign standard and wayfinding plan. Ideally, all message updates should be documented and managed by a designated staff member or department such as Interior Design.

Message Layout A

IN-15.71/.75 Interior Signage Drawings Ceiling Mounted Directional and Department ID

Message Layout A

Message Layout B

Section 3.1 324

325 Section 3.1

IN-15.72/.76 Interior Signage Drawings Ceiling Mounted Directional and Department ID

Size Sign Face:

12" High x 80" Wide (304.8 mm H x 2032 mm W)

Description & Use Ceiling-mounted sign for directional and department identification information. Can be single or double-sided.

Message Configuration Refer to message layout drawings for dimensions.

Sign Components Varies by component sign system:

Component Strips, Flat Insert or J-Track Insert-Based Sign Systems.

Graphic Process Applied vinyl for semi-permanent messages or digitally printed insert for updatable messages.

Colors Refer to the color chart in the Appendix.

Typography Helvetica Bold

Mounting Suspended from ceiling with braided stainless steel cable.

Installation Mount at minimum 80" (2032 mm) above finished flooring to the bottom of the sign.

See Section 2.1 for installation details.

Recommendations Keep directional messages simple, providing only information necessary to decide at that specific location. List destinations in alphanumeric order and limit the number per sign.

Use consistent terminology throughout the facility, online, and on appointment letters.

Refer to the VHA Standardized Nomenclature document for a list of approved department names.

Inserts should follow an approved template established as part of the facility's sign standard and wayfinding plan. Ideally, all message updates should be documented and managed by a designated staff member or department such as Interior Design.

Message Layout A

IN-15.72/.76 Interior Signage Drawings Ceiling Mounted Directional and Department ID

Message Layout A

Message Layout B

Section 3.1 326

327 Section 3.1

IN-16.51/.55 Interior Signage Drawings Soffit Mounted Directional and Department ID

Size Sign Face:

6" High x 40" Wide (152.4 mm H x 1016 mm W)

Description & Use Wall or soffit-mounted sign for directional and department identification information.

Message Configuration Refer to message layout drawings for dimensions.

Sign Components Varies by component sign system:

Component Strips, Flat Insert or J-Track Insert-Based Sign Systems.

Graphic Process Applied vinyl for semi-permanent messages or digitally printed insert for updatable messages.

Colors Refer to the color chart in the Appendix.

Typography Helvetica Bold

Mounting Concealed mechanical fasteners -do not use on firewalls without proper accommodations.

Installation See Section 2.1 for installation details.

Recommendations Keep directional messages simple, providing only information necessary to decide at that specific location. List destinations in alphanumeric order and limit the number per sign.

Use consistent terminology throughout the facility, online, and on appointment letters.

Refer to the VHA Standardized Nomenclature document for a list of approved department names.

Inserts should follow an approved template established as part of the facility's sign standard and wayfinding plan. Ideally, all message updates should be documented and managed by a designated staff member or department such as Interior Design.

Message Layout A

IN-16.51/.55 Interior Signage Drawings Soffit Mounted Directional and Department ID

Message Layout A

Message Layout B

Section 3.1 328

329 Section 3.1

IN-16.52/.56 Interior Signage Drawings Soffit Mounted Directional and Department ID

Size Sign Face:

12" High x 40" Wide (304.8 mm H x 1016 mm W)

Description & Use Wall or soffit-mounted sign for directional and department identification information.

Message Configuration Refer to message layout drawings for dimensions.

Sign Components Varies by component sign system:

Component Strips, Flat Insert or J-Track Insert-Based Sign Systems.

Graphic Process Applied vinyl for semi-permanent messages or digitally printed insert for updatable messages.

Colors Refer to the color chart in the Appendix.

Typography Helvetica Bold

Mounting Concealed mechanical fasteners -do not use on firewalls without proper accommodations.

Installation See Section 2.1 for installation details.

Recommendations Keep directional messages simple, providing only information necessary to decide at that specific location. List destinations in alphanumeric order and limit the number per sign.

Use consistent terminology throughout the facility, online, and on appointment letters.

Refer to the VHA Standardized Nomenclature document for a list of approved department names.

Inserts should follow an approved template established as part of the facility's sign standard and wayfinding plan. Ideally, all message updates should be documented and managed by a designated staff member or department such as Interior Design.

Message Layout A Message Layout B

Message Layout C Message Layout D

IN-16.52/.56 Interior Signage Drawings Soffit Mounted Directional and Department ID

Message Layout A

Message Layout B

Message Layout C

Message Layout D

Section 3.1 330

331 Section 3.1

IN-16.61/.65 Interior Signage Drawings Soffit Mounted Directional and Department ID

Size Sign Face:

6" High x 60" Wide (152.4 mm H x 1524 mm W)

Description & Use Wall or soffit-mounted sign for directional and department identification information.

Message Configuration Refer to message layout drawings for dimensions.

Sign Components Varies by component sign system:

Component Strips, Flat Insert or J-Track Insert-Based Sign Systems.

Graphic Process Applied vinyl for semi-permanent messages or digitally printed insert for updatable messages.

Colors Refer to the color chart in the Appendix.

Typography Helvetica Bold

Mounting Concealed mechanical fasteners -do not use on firewalls without proper accommodations.

Installation See Section 2.1 for installation details.

Recommendations Keep directional messages simple, providing only information necessary to decide at that specific location. List destinations in alphanumeric order and limit the number per sign.

Use consistent terminology throughout the facility, online, and on appointment letters.

Refer to the VHA Standardized Nomenclature document for a list of approved department names.

Inserts should follow an approved template established as part of the facility's sign standard and wayfinding plan. Ideally, all message updates should be documented and managed by a designated staff member or department such as Interior Design.

Message Layout A

IN-16.61/.65 Interior Signage Drawings Soffit Mounted Directional and Department ID

Message Layout A

Message Layout B

Section 3.1 332

333 Section 3.1

IN-16.62/.66 Interior Signage Drawings Soffit Mounted Directional and Department ID

Size Sign Face:

12" High x 60" Wide (304.8 mm H x 1524 mm W)

Description & Use Wall or soffit-mounted sign for directional and department identification information.

Message Configuration Refer to message layout drawings for dimensions.

Sign Components Varies by component sign system:

Component Strips, Flat Insert or J-Track Insert-Based Sign Systems.

Graphic Process Applied vinyl for semi-permanent messages or digitally printed insert for updatable messages.

Colors Refer to the color chart in the Appendix.

Typography Helvetica Bold

Mounting Concealed mechanical fasteners -do not use on firewalls without proper accommodations.

Installation See Section 2.1 for installation details.

Recommendations Keep directional messages simple, providing only information necessary to decide at that specific location. List destinations in alphanumeric order and limit the number per sign.

Use consistent terminology throughout the facility, online, and on appointment letters.

Refer to the VHA Standardized Nomenclature document for a list of approved department names.

Inserts should follow an approved template established as part of the facility's sign standard and wayfinding plan. Ideally, all message updates should be documented and managed by a designated staff member or department such as Interior Design.

Message Layout A

IN-16.62/.66 Interior Signage Drawings Soffit Mounted Directional and Department ID

Message Layout A

Message Layout B

Section 3.1 334

335 Section 3.1

IN-16.71/.75 Interior Signage Drawings Soffit Mounted Directional and Department ID

Size Sign Face:

6" High x 80" Wide (152.4 mm H x 2032 mm W)

Description & Use Wall or soffit-mounted sign for directional and department identification information.

Message Configuration Refer to message layout drawings for dimensions.

Sign Components Varies by component sign system:

Component Strips, Flat Insert or J-Track Insert-Based Sign Systems.

Graphic Process Applied vinyl for semi-permanent messages or digitally printed insert for updatable messages.

Colors Refer to the color chart in the Appendix.

Typography Helvetica Bold

Mounting Concealed mechanical fasteners -do not use on firewalls without proper accommodations.

Installation See Section 2.1 for installation details.

Recommendations Keep directional messages simple, providing only information necessary to decide at that specific location. List destinations in alphanumeric order and limit the number per sign.

Use consistent terminology throughout the facility, online, and on appointment letters.

Refer to the VHA Standardized Nomenclature document for a list of approved department names.

Inserts should follow an approved template established as part of the facility's sign standard and wayfinding plan. Ideally, all message updates should be documented and managed by a designated staff member or department such as Interior Design.

Message Layout A

IN-16.71/.75 Interior Signage Drawings Soffit Mounted Directional and Department ID

Message Layout A

Message Layout B

Section 3.1 336

337 Section 3.1

IN-16.72/.76 Interior Signage Drawings Soffit Mounted Directional and Department ID

Size Sign Face:

12" High x 80" Wide (304.8 mm H x 2032 mm W)

Description & Use Wall or soffit-mounted sign for directional and department identification information.

Message Configuration Refer to message layout drawings for dimensions.

Sign Components Varies by component sign system:

Component Strips, Flat Insert or J-Track Insert-Based Sign Systems.

Graphic Process Applied vinyl for semi-permanent messages or digitally printed insert for updatable messages.

Colors Refer to the color chart in the Appendix.

Typography Helvetica Bold

Mounting Alternate: Concealed mechanical fasteners - do not use on firewalls without proper accommodations.

Installation See Section 2.1 for installation details.

Recommendations Keep directional messages simple, providing only information necessary to decide at that specific location. List destinations in alphanumeric order and limit the number per sign.

Use consistent terminology throughout the facility, online, and on appointment letters.

Refer to the VHA Standardized Nomenclature document for a list of approved department names.

Inserts should follow an approved template established as part of the facility's sign standard and wayfinding plan. Ideally, all message updates should be documented and managed by a designated staff member or department such as Interior Design.

Message Layout A

IN-16.72/.76 Interior Signage Drawings Soffit Mounted Directional and Department ID

Message Layout A

Message Layout B

Section 3.1 338

Size Sign Face:

39" High x 34" Wide (990.6 mm H x 863.6 mm W)

Description & Use This sign is used to display wayfinding maps of a facility near primary entrances and lobbies.

These maps help viewers orient themselves upon enter the facility and plan a route to their destination.

Message Configuration Refer to message layout drawings for dimensions.

Sign Components Component based sign system

See Section 2.1 for applicable component sign system styles.

Graphic Process Header: Direct second surface digital print or silk-screened

Message Insert: Digital Print Insert

Colors Refer to the color chart in the Appendix.

Typography Helvetica

Mounting Alternate: Concealed mechanical fasteners

Installation See Section 2.1 for installation details.

Recommendations Maps should be oriented to the viewer. The top of the map should be the direction that the viewer is standing while facing the sign.

Maps should be a stylized and simplified representation of the floor plan. Avoid excessively detailed illustrations.

Use consistent terminology throughout the facility, online, and on appointment letters.

Refer to the VHA Standardized Nomenclature document for a list of approved department names.

See Section 4.2 for more about wayfinding maps and directories.

Interior Signage Drawings PG 18-10 Signage Design Manual May 16, 2023

Large Orientation Map

Section 3.1 339

IN-17.01

IN-17.01 Interior Signage Drawings Large Orientation Map

Message Layout B

Message Layout A

Section 3.1 340

IN-17.02

Size Sign Face:

39" High x 34" Wide (990.6 mm H x 863.6 mm W)

Description & Use This sign is used to display the directory list of patient & visitor focused destinations within the facility.

Message Configuration Refer to message layout drawings for dimensions.

Sign Components Component based sign system

See Section 2.1 for applicable component sign system styles.

Graphic Process Header: Direct second surface digital print or silk-screened

Message Insert: Digital Print Insert

Colors Refer to the color chart in the Appendix.

Typography Helvetica

Mounting Concealed mechanical fasteners

Installation See Section 2.1 for installation details.

Recommendations A single directory insert typically fits 15 to 16 lines of copy at a minimum text height of 3/8" (9.525 mm).

Make sure the number of inserts is sufficient for the size of the facility and number of destinations.

Use consistent terminology throughout the facility, online, and on appointment letters.

Refer to the VHA Standardized Nomenclature document for a list of approved department names.

See Section 4.2 for more about wayfinding maps and directories.

Interior Signage Drawings

Large Directory Listing

Section 3.1 341

IN-17.02 Interior Signage Drawings Large Directory Listing

Message Layout B

Section 3.1 342

- Interior Signage Drawings May 16, 2023

Orientation Map

IN-17.03

PG 18-10 Signage Design Manual

Size Sign Face:

27 1/2" High x 22 1/2" Wide (698.5 mm H x 571.5 mm W)

Description & Use This sign is used to display wayfinding maps of the current floor of the building near elevator lobbies or secondary entrances. These maps help viewers orient themselves as they exit the elevator or enter an area.

Message Configuration Refer to message layout drawings for dimensions.

Sign Components Component based sign system

See Section 2.1 for applicable component sign system styles.

Graphic Process Header: Direct second surface digital print or silk-screened

Message Insert: Digital Print Insert

Colors Refer to the color chart in the Appendix.

Typography Helvetica

Mounting Concealed mechanical fasteners

Installation See Section 2.1 for installation details.

Recommendations Maps should be oriented to the viewer. The top of the map should be the direction that the viewer is standing while facing the sign.

Maps should be a stylized and simplified representation of the floor plan. Avoid excessively detailed illustrations.

Use consistent terminology throughout the facility, online, and on appointment letters.

Reference the VHA Standardized Nomenclature document for a list of approved department names.

See Section 4.2 for more about wayfinding maps and directories.

Section 3.1 343

IN-17.03 Interior Signage Drawings Orientation Map

Message Layout A

Message Layout B

Section 3.1 344

IN-17.04

Size Sign Face:

27" High x 34 1/4" Wide (685.8 mm H x 869.95 mm W)

Description & Use This sign is used to display the directory list of patient & visitor focused destinations within the facility.

Message Configuration Refer to message layout drawings for dimensions.

Sign Components Component based sign system

See Section 2.1 for applicable component sign system styles.

Graphic Process Header: Direct second surface digital print or silk-screened

Message Insert: Paper or acetate sheet with digital print

Colors Refer to the color chart in the Appendix.

Typography Helvetica

Mounting Concealed mechanical fasteners

Installation See Section 2.1 for installation details.

Recommendations A single directory insert typically fits 15 to 16 line of copy at a minimum text height of 3/8". Make sure the number of inserts is sufficient for the size of the facility and number of destinations.

Use consistent terminology throughout the facility, online, and on appointment letters.

Refer to the VHA Standardized Nomenclature document for a list of approved department names.

See Section 4.2 for more about wayfinding maps and directories.

Interior Signage Drawings Directory Listing

Section 3.1 345

IN-17.04 Interior Signage Drawings Directory Listing

Message Layout A

Message Layout B

Section 3.1 346

- Interior Signage Drawings Small Directory Listing

PG 18-10 Signage Design Manual May 16, 2023

Section 3.1 347

IN-17.05

Size Top:

27" High x 17" Wide (685.8 mm H x 431.8mm W)

Description & Use This sign is used to display the directory list of patient & visitor focused destinations within the facility.

Message Configuration Refer to message layout drawings for dimensions.

Sign Components Component based sign system

See Section 2.1 for applicable component sign system styles.

Graphic Process Header: Direct second surface digital print or silk-screened

Message Insert: Paper or acetate sheet with digital print

Colors Refer to the color chart in the Appendix.

Typography Helvetica

Mounting Preferred: Concealed mechanical fasteners

Alternate: Double-sided VHB foam tape and silicone adhesive

Installation See Section 2.1 for installation details.

Recommendations A single directory insert typically fits 15 to 16 lines of copy at a minimum text height of 3/8". Make sure the number of inserts is sufficient for the size of the facility and number of destinations.

Use consistent terminology throughout the facility, online, and on appointment letters.

Refer to the VHA Standardized Nomenclature document for a list of approved department names.

See Section 4.2 for more about wayfinding maps and directories.

IN-17.05 Interior Signage Drawings

Small Directory Listing

Message Layout A

Message Layout B

348 Section 3.1

-IN-18.01

Size 1 1/2" High (38.1 mm H)

2" High (50.8 mm H)

Other sizes may be used as appropriate.

Description & Use Vinyl letters for use at glass entry doors to rooms or departments that are used by patients and the public.

Message Configuration Refer to layout drawing for lettering sizes and dimensions.

Graphic Process Surface applied high performance vinyl.

Colors Text: White or other color that provides high contrast.

Refer to the color chart in the Appendix.

Typography Helvetica

Mounting Glass sidelight and glass doors

Installation Apply to front reading surface of glass or second surface of glass with reverse (backward) cut letters.

Interior Signage Drawings May 16, 2023

Vinyl Applied Letters

Vinyl letters applied to double doors

Vinyl letters applied to double door sidelight

Vinyl letters applied to single door

Vinyl letters applied to single door sidelight

Section 3.1 349

IN-18.01 Interior Signage Drawings Glass Door and Side Light Graphics

Message Layout A – 1 1/2" Text (Sample Text Shown)

Message Layout B – 2" Text (Sample Text Shown)

Section 3.1 350

- -IN-19.01-.03 Interior Signage Drawings

351 Section 3.1

PG 18-10 Signage Design Manual May 16, 2023

Dimensional Letters Size IN-19.01: 3" High (558.8 mm H)

IN-19.02: 4" High (711.2 mm H)

IN-19.03: 6" High (863.6 mm H)

Description & Use Identification of information counters, major departments, or services.

Message Configuration Refer to layout drawing for lettering sizes and dimensions.

Sign Components Painted acrylic

Graphic Process Cut out acrylic dimensional letters

Colors Lettering color should have a high contrast with surrounding wall color and surface.

Refer to the color chart in the Appendix.

Typography Helvetica

Mounting Silicone adhesive and studs

Installation On wall or above wall openings

Recommendations Dimensional letters provide high impact, high visibility, and formal identification. Do not use for departments or services that have frequent relocations or name changes. Suggested typical uses would be for Information, Check In, Canteen, Pharmacy, etc.

IN-19.01-.03 Interior Signage Drawings Dimensional Letters

IN-19.01

IN-19.02

IN-19.03

Section 3.1 352

Sign Overview Code & Life Safety Signage Drawings

3.2.CODE & LIFE SAFETY SIGNS

SECTION 3.2

CODE & LIFE SAFETY SIGNAGE DRAWINGS

Introduction This section contains detailed drawings of all typical Code & Life Safety sign types for VA facilities. Individual facilities may have unique conditions that require modifications or additional sign types not shown in the Manual. The following drawings provide general design intent and do not function as fabrication-ready shop drawings.

Guidelines

• The drawings should be used as a starting point to develop a sign standard with a component-based sign system, sign types, colors, finishes, and graphics specific to the individual facility.

• Please review Section 2.2 Code & Life Safety Signage Guidelines which contains information regarding Planning, Programming, Construction, and Installation prior to starting signage projects.

Requirements

• Most Code and Life Safety signs have specific location and placement requirements based upon their use, function, and code requirements. Each type of sign should be installed as shown in the following illustrations. This may require that furniture be moved, bulletin boards be relocated, etc. to ensure the Code and Life Safety sign is installed in its correct location.

• The use of component-based sign systems is required at VA facilities except for door-mounted signs which consist of a low-profile acrylic plaque mounted with VHB tape and silicone adhesive (see Sections 2.1.5 & 2.1.6). The exact materials, parts, finishes, and dimensions of a component sign system will vary by manufacturer.

• Helvetica Lt Std is the standard font required for use in signage at all VA facilities with the exclusion of NCA locations.

• Design and placement of all signs should meet ABA requirements where applicable. Refer to Section 4.1 Appendix for a summary of applicable requirements.

Message Inserts

• Insert-based sign messages should follow an approved template established as part of the facility's sign standard and wayfinding plan.

• To increase durability and moisture resistance, updatable inserts should be printed on synthetic paper or clear acetate sheets. Standard printer paper can absorb moisture causing wrinkles and yellowing over time.

Section 3.2 354

PG 18-10 Signage Design Manual May 16, 2023

Sign Overview Code & Life Safety Signage Drawings

Life Safety Colors Code and Life Safety signs use specific colors to indicate the purpose of their message. The exact color values listed below are not required to meet code but are intended to ensure that safety signs are highly visible and easily recognizable, even from a distance or in low-light conditions. Color matching accuracy will differ based on the production processes used. Near matches of the colors below are acceptable.

DANGER Red: Indicates danger or location of fire protection equipment.

PMS value: 186 C CMYK values: 0,100,75,4

WARNGING - Orange: Indicates dangerous equipment, and bio-hazards.

PMS value: 151 C CMYK values: 0,55,100,0

CAUTION - Yellow: Indicates caution regarding physical hazards.

PMS value: 109 C CMYK values: 0,10,100,0

SAFETY Green: Indicates the location of safety equipment and instructions.

PMS value: 335 C CMYK values: 100,0,58,22

NOTICE Blue: Indicates notices and warnings that are not physically dangerous.

PMS value: 285 C CMYK values: 90,48,0,0

Purple: Indicates radiation hazards, often in combination with yellow.

PMS value: 259 C CMYK values: 69,100,1,5

The exact color values of neutral background colors illustrated on sign drawings in this section are not mandatory. White or other neutral color values may be used in order to complement interior environments as long as sufficient contrast is achieved.

Section 3.2 355

Sign Designations Each sign in the program manual has been given a specific sign type number designation. This designation provides a common description that can be referenced when programming a site and ordering signs. The following explains how the sign type designations are derived.

IN - 01 .28 .03 C

IN Designates an interior sign.

01 Two-digit number identifies the Code & Life Safety sign family.

28 The two-digit number following the period identifies a specific sign type within the sign family.

.03 The two-digit number following the period identifies a specific sup-group of sign within the sign family.

C The letter designates a specific sign configuration, version and / or layout for graphics or symbols.

Section 3.2 356

IN-01.01.01

Evacuation Plan Sign

IN-01.01.03

Guest Rooms Evacuation Plan Sign

IN-01.01.01 IN-01.01.03 A IN-01.01.03 B

IN-01.02

Fire Extinguisher Identification Sign

IN-01.31

Fire Extinguisher Identification Flag Sign

IN-01.36

AED Identification Flag Sign

IN-01.37

Crash Cart Identification Flag Sign

IN-01.03

Fire Procedure “R.A.C.E.” Sign

IN-01.04

Elevator Call Button Sign

IN-01.05

Fire Door Sign

IN-01.06

No Exit Sign

IN-01.07.01-.04

Exit Sign

IN-01.08

Automatic Fire Door Sign – Hinged Door

IN-01.09

Automatic Fire Shutter Sign – Roll Up

IN-01.02 IN-01.31 IN-01.36 IN-01.37

IN-01.03 IN-01.04 IN-01.05 IN-01.06

IN-01.07.01-04 IN-01.08 IN-01.09

Section 3.2 357

IN-01.13

Push/Pull Alarm Identification Sign

IN-01.14

Open Door Fire Safety Sign

IN-01.26

Push to Exit Sign

IN-01.27

Emergency Push to Open Sign

IN-01.28

Emergency Slide to Open Sign

IN-01.10

Stair Identification Sign

IN-01.11

NFPA Stairwell Identification Sign

IN-01.12

Area of Refuge Sign

IN-01.25

No Re-Entry Floor Sign

IN-01.29

Direction of Exit Sign

IN-01.30

No Re-Entry Sign

IN-01.33

Re-Entry Sign

IN-01.13 A & B IN-01.14

IN-01.26 IN-01.27 IN-01.28

IN-01.10 IN-01.11 IN-01.12

IN-01.25 IN-01.29 IN-01.33 IN-01.30

Section 3.2 358

IN-01.15

Hazardous Material Information Sign

IN-01.16.01

Oxygen in Use Warning Sign

IN-01.16.02

Medical Gases Warning Sign

IN-01.16.03

Oxidizing Gases Warning Sign

IN-01.16.04

Positive Pressure Gases Warning Sign

IN-01.17

Compressed Gas Warning Sign

IN-01.18

Nonflammable Anesthesia Restriction Sign

IN-01.19

Radioactive Material Warning Sign

IN-01.22

Biohazard Warning Sign

IN-01.15 IN-01.16.01 IN-01.16.02

IN-01.16.03 IN-01.16.04 IN-01.18 IN-01.17

IN-01.20

Radioactive Area Warning Sign

IN-01.35

Radiation Warning Sign

IN-01.21

High Voltage Warning Sign

IN-01.20 IN-01.21 IN-01.35 IN-01.19

IN-01.23

Laser Warning Sign

IN-01.24

Occupational Exposure Area Warning Sign

IN-01.32

IN-01.22 IN-01.23 IN-01.32 IN-01.24

CAUTION

Pregnancy Notification Sign

Section 3.2 359

IN-01.34

Proper Attire Required Beyond this Point Sign

IN-01.38

Emergency Eye Wash Station Sign

IN-01.39

Emergency Shower Sign

IN-01.40

Emergency Shower / Emergency Eye Wash Station Sign

IN-01.34 IN-01.38 IN-01.39 IN-01.40

Section 3.2 360

IN-01.01.01 Code & Life Safety Signage Drawings Evacuation Plan Sign

Size 15" High x 17" Wide (381 mm H x 431.8 mm W)

Description and Use This sign type is ONLY required for areas with hotel / dormitory type occupancy such as “Hoptels” and Fishers Houses. It is NOT required for inpatient settings or other healthcare areas.

When Required:

The International Fire Code (IFC) requires the posting of evacuation plans in each guest room (sign type IN-01.01.03) and at each elevator bank (sign type IN-01.01.01).

The evacuation map must indicate the viewer location (You Are Here), display a minimum of two evacuation routes, and indicate the location of fire extinguishers and fire alarm pull stations.

Optional Use:

Evacuation plans can be located at elevator banks, exit stairwells, waiting areas, and other high-traffic locations at the discretion of the facility.

Message Configuration Refer to layout drawing for lettering sizes and dimensions.

Sign Components Component based sign system

See Section 2.1.5 Construction for applicable component sign system styles.

Graphic Process Sign: Direct digital on second surface print or silk-screened

Insert: Printed

Colors Refer to the chart in the Appendix.

Typography Helvetica Bold

Mounting Preferred: Concealed mechanical fasteners Alternate: Double-sided VHB foam tape and silicone adhesive

Installation Mount on wall, 60" (1524 mm) to the center of the sign.

Message Layout

The Joint Commission and the Life Safety Code do not require these signs be installed in Healthcare Occupancies, but the local fire department may. If requested, coordinate location with their requirements. If the facility chooses to use posted evacuation maps be sure to keep them up-to-date and accurate, so they reflect the current state of the area.

Section 3.2 361

IN-01.01.01 Code & Life Safety Signage Drawings Evacuation Plan Sign

Message Layout

Section 3.2 362

- Code & Life Safety Signage Drawings Guest Rooms Evacuation Plan Sign

Message Layout A

PG 18

IN-01.01.03

-10 Signage Design Manual May 16, 2023

Size Message Layout A:

1'-1/2" High x 11" Wide (317.5 mm H x 279.4 mm W)

Message Layout B:

9 1/2" High x 11" Wide (241.3 mm H x 279.4 mm W)

Description and Use This sign type is ONLY required for areas with hotel / dormitory type occupancy such as “Hoptels” and Fishers Houses. It is NOT required for inpatient settings or other healthcare areas.

When Required:

The International Fire Code (IFC) requires the posting of evacuation plans in each guest room (sign type IN-01.01.02) and at each elevator bank (sign type IN-01.01.01).

The evacuation map must indicate the viewer location (You Are Here), display a minimum of two evacuation routes, and indicate the location of fire extinguishers and fire alarm pull stations.

Message Configuration Refer to layout drawing for lettering sizes and dimensions.

Sign Components Acrylic Construction 1/16” (1.5 mm) non-glare acrylic sign face with subsurface background color creating a clear window, 1/16” spacer to create window, 1/8” acrylic back-panel surface printed or painted

Graphic Process Sign: Direct digital print on second surface or silk-screened

Insert: Printed Message Layout B

Colors Refer to the chart in the Appendix.

Typography Helvetica Bold

Mounting Double-sided VHB foam tape and silicone adhesive

Installation Mount on wall or door, 60" (1524

mm) to top or center of the sign.

Section 3.2 363

IN-01.01.03 Code & Life Safety Signage Drawings

Guest Rooms Evacuation Plan Sign

Section 3.2 364

IN-01.02 Code & Life Safety Signage Drawings Fire Extinguisher Identification Sign

Size 9" High x 9" Wide (228.6 mm H x 228.6 mm W)

Description and Use This sign is used to locate and identify fire extinguisher cabinets.

Fire extinguisher signs should be installed perpendicular to the wall (sign type IN-01.31). Only use sign type IN-01.02 where visibility of a perpendicular sign would not be adequate.

Message Configuration Refer to layout drawing for lettering sizes and dimensions.

Sign Components Component based sign system

See Section 2.1.5 Construction for applicable component sign system styles.

Graphic Process Direct digital print on second surface or silk-screened

Colors Text and Symbol: White Background: Red Refer to the chart in the Appendix.

Typography Helvetica Bold

Mounting Preferred: Concealed mechanical fasteners Alternate: Double-sided VHB foam tape and silicone adhesive

Installation Mount on wall, 72" (1828.8 mm) to top of sign.

Section 3.2 365

IN-01.02 Code & Life Safety Signage Drawings Fire Extinguisher Identification Sign

Section 3.2 366

-IN-01.03 Code & Life Safety Signage Drawings

Fire Procedure “R.A.C.E.” Sign Size 6" High x 9" Wide (152.4 mm H x 228.6 mm W)

Description and Use Fire procedure sign to be installed above fire alarm pull stations as needed.

This sign is optional.

All of the information provided on these signs should be coordinated with the facility personnel who are responsible for the facility fire plan.

Message Configuration Refer to layout drawing for lettering sizes and dimensions.

Sign Components Component based sign system

See Section 2.1.5 Construction for applicable component sign system styles.

Graphic Process Direct digital print on second surface or silk-screened

Colors Text: White Background: Red Refer to the chart in the Appendix.

Typography Helvetica Bold

Mounting Preferred: Concealed mechanical fasteners Alternate: Double-sided VHB foam tape and silicone adhesive

Installation Mount on wall adjacent to fire alarm pull station, typically centered 2" (50.8 mm) above.

Section 3.2 367

IN-01.03 Code & Life Safety Signage Drawings Fire Procedure “R.A.C.E.” Sign

Section 3.2 368

IN-01.04 Code & Life Safety Signs Elevator Call Button Sign

Size 9" High x 6" Wide (228.6 mm H x 152.4 mm W)

Description and Use Elevator call button fire procedure sign to be installed at elevators.

Message Configuration Refer to layout drawing for lettering sizes and dimensions.

Sign Components Component based sign system

See Section 2.1.5 Construction for applicable component sign system styles.

Graphic Process Direct digital print on second surface or silk-screened

Colors Text: Black Symbol: Black, Red, & White Background: White Refer to the chart in the Appendix.

Typography Helvetica Bold

Mounting Preferred: Concealed mechanical fasteners Alternate: Double-sided VHB foam tape and silicone adhesive

Installation Mount on wall adjacent to elevator call button, typically centered 2" (50.8 mm) above.

Section 3.2 369

Code & Life Safety Signage Drawings Elevator Call Button Sign

IN-01.04

Section 3.2 370

IN-01.05 Code & Life Safety Signage Drawings Fire Door Sign

Size 9" High x 9" Wide (228.6 mm H x 228.6 mm W)

Description and Use This sign is used to identify fire doors typically at stairwells. Do not install this sign on smoke barrier doors. See NFPA 80 for additional information.

Exception: Sign shall not be provided for fire doors that are held open by automatic devices.

Message Configuration Refer to layout drawing for lettering sizes and dimensions.

Sign Components Component based sign system (wall mount) or acrylic plaque (door mount).

See Section 2.1.5 Construction & Section 2.1.6 Installation for applicable component sign system styles and acrylic construction.

Graphic Process Direct digital print on second surface or silk-screened

Colors Text: White Background: Red Refer to the chart in the Appendix.

Typography Helvetica Bold

Mounting Preferred: Concealed mechanical fasteners Alternate: Double-sided VHB foam tape and silicone adhesive

Installation Preferred:

On wall: 60" (1524 mm) to top of sign, 6" away from door frame’s latch side.

Optional:

Mount centered on door 60" (1524

mm) above finished floor to the center or top of the sign.

Section 3.2 371

IN-01.05 Code & Life Safety Signage Drawings Fire…