S02 - 815IC3040 Bid Set Dwgs LINC Bk02.pdf

PDF 5 MB Posted

Attached to
Y1QA--815IC3040 - Facility Renovations - Long Island NC 36C786-20-B-0029 is Replacing 36C786-20-B-0011
Solicitation number
36C78620B0029
Issued by

About this file

This is a solicitation for facility renovations at the Long Island National Cemetery. The Department of Veterans Affairs National Cemetery Administration is seeking proposals to renovate and improve facilities, including the administration building and maintenance building. The solicitation is open to all small business concerns, as the original set-aside for service-disabled veteran-owned small businesses did not yield two or more eligible and capable vendors. Proposals are due by June 5, 2020, with award anticipated in late 2020. The scope of work includes renovations, improvements, and repairs to both buildings, along with associated site work.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T O

O P

E R

A T

IN

G

M E

C H

A N

IS

M

3' -4

M

A X4'

4'

0'

6'

FULL LENGTH MIRROR

(FMR)

PAPER TOWEL

DISPENSER WALL MTD

(PTD)

ROBE HOOK

(RH)

SOAP DISPENSER

SURFACE

(SD)

SANITARY NAPKIN

DISPOSAL UNIT

SURFACE MTD

(WOMEN'S ONLY)

(SNWS)

COMBINATION PAPER TOWEL

DISPENSER / WASTE

RECEPTACLE (PTWR)

D

IS

P E

N S

E R

S

LO

T

3'

TOILET SEAT COVER

DISPENSER

SURFACE MTD

(SCDS)

6'

SHOWER CURTAIN ROD

(SCR)

T O

B O

T T

O M

3' -4

M

A X

SOAP DISH

SURFACE

MTD

(SDS)

4'

TOWEL BAR

(TB)

4'

TOWEL PIN

(TP)

4' -0

M

A X

3' -0

M

IN

WARM-AIR DRYER

(WAD)

4'

6'

HAND HELD

SHOWER

SHOWER HEAD

MIN 59"

LONG HOSE

U F

C G

U

ID

E

LI

N E

2'

4' -0

M

A X

3' -4

M

IN

4' -0

M

A X

3' -4

M

IN

3' -4

A

B O

V E

F

IN

IS

H

F

LO

O R

T O

B O

T T

O M

O F

R E

F L

S U

R F

A C

E

MIRROR

(MR)

TOILET PAPER

DISPENSER

(TPD)

T O

'-0

M

A X

1' -3

M

IN

VARIES FROM 3'-4" HEIGHT

FOR MAX 6" DEPTH, TO 4'-0"

HEIGHT FOR MAX 1/2" DEPTH

VARIES FROM 3'-0" HEIGHT

FOR MAX 9" DEPTH, TO

4'-0" HEIGHT FOR MAX 1/2" DEPTH

CENTER OF OPERATING

MECHANISM

0'

1'

1' - 3 3/16"

MIN CLEAR

1' - 3"

M A

X T

O R

IM

2'

0"

R E

F

LE

C T

E D

S U

R F

A C

E O

F M

IR

R

O R

3' -4

M

A X

T O

B O

VERIFY SIZE WITH PLANS

AND ELEVATIONS

MIN

8" DEEP

T O

R

IM

2' -1

0" M

A X

2'-1" MAX

1'-5" MIN

9" M

IN

9" M

IN

SIDE VIEW FRONT VIEW

1'-5" MIN

LAVATORY

PLUMBING LINES

WITHIN HATCHED

AREA REQUIRED

TO BE INSULATED

LINES OF REQUIRED

CLEARANCE

FINISH FLOOR

4'-0" MIN CLR

2'

M

IN

0'

CLEAR SPACE

ALLOWABLE FOR

ACCESSIBILITY

MIRROR

C

LR

K N

E E

S P

A C

E

2'

M

IN

0'

LINES OF REQUIRED

CLEARANCE

CLEARANCE

6" MAX TOE

PT-2

MR

3' - 9 7/8"

CLEAR FIN TO FIN

3' - 0"

SHOWER SEAT

GRAB BAR

SD

2'

0"

B1

AE310

D

PT-2

GRAB BAR

SNWS

TPD

PT-2

GRAB BAR

D

PT-2 GRAB BAR

SHOWER SEAT

4 EQ @ 6'-0"

7'

ADA ADA

PT-2

PTWR

RH

1' - 0" 4' - 0"

E

PT-2

CMU WALL, P-1

B1

AE310

MR

PT-2

SD

2'

0"

E

PT-2

TPD

REF,A1

SCRIBE 1' - 3" 2' - 6" 2' - 6" 2' - 6" 2' - 6" SCRIBE

2'

0"

1'

3'

" MICROWAVE, A2

PL-1

PL-1

2' - 1 3/32" 3' - 0" 3' - 0" 1' - 9" 1' - 6" SCRIBE

F1

AE410

F2

AE410

F3

AE410

F5

AE410

SSM-1

F7

AE410

7'

6 EQ @ 9'-0"

LOCKERS

9 EQ @ 13'-6"

2'

6"

U N

LE

S

S N

O T

E D

O T

H E

R W

IS

E

UNDER

CABINET LIGHT,

SEE ELEC

ADJUSTABLE

SHELF

CABINET DOOR

CABINET DOOR

PULL

CABINET

BACK

1' - 3"

3"

2'

0'

2'

0"

BASE AS SCH

COUNTERTOP

CABINET DOOR

CABINET DOOR

PULL

BACKSPLASH

CABINET BACK

CAULKING

SIDESPLASH @

ADJACENT WALL

WHERE OCCURS

SINK WHERE

OCCURS

2' - 1"

4"

3' - 0"

FIXED / HAND

HELD

SHOWER

SPRAY UNIT

W/ 59" LONG

MIN HOSE

CONTROL AREA

3' - 0"

1' - 6"

FOLD UP

SHOWER

SEAT

1' -7

M

A X

1' -5

M

IN

SHOWER

CURTAIN ROD

MOUNT 6'-6" AFF

3' -0

M

A X

T O

B A

R

2' -9

M

IN

4' -0

M

A X

3' -2

M

IN

3' -0

M

A X

T O

B A

R

2' -9

M

IN

SIDE VIEW FRONT VIEW

1'-3" MAX 1' - 6"

FIN TO FIN

3' - 0"

F

IN

T O

F

IN

3'

1' - 6"

36" X 48" CLEAR

FLOOR SPACE

S E

A T

W A

LL

C O

N T

R O

L W

A

LL

1'

1/

S

ID

E V

IE

W

1/

2" M

A X

1'-11" MAX

1'-10" MIN

1' -3

M

A X

1' -2

M

IN

3"

M A

X2 1/2" MAX

1'-4" MAX

1'-3" MIN

PLAN

0'

M A

X

4" MAX

6" M

A X

3" M

IN

VERTICAL GRAB

BAR

GRAB BAR

VERTICAL

GRAB BAR

GRAB BAR

GRAB BAR

FRONT VIEW

1'

1/

2" 1/

2"

6" 1/

4" 4"

3"

1 1/2"1 1/2"

ADJUSTABLE

SHELF

BASE AS SCH

COUNTERTOP

CABINET DOOR

CABINET

DRAWER PULL

BACKSPLASH

CABINET BACK

CAULKING

SIDESPLASH @

ADJACENT WALL

WHERE OCCURS

CABINET

DRAWER

CABINET DOOR PULL

2' - 1"

2'

0"

4"

3"

1/ 4"

8" 1/

4" 6"

1/ 2"

1/

2"

/2

C

LE

A R

0'

2'

0"

FILE FOLDER

DRAWER

BASE AS SCH

COUNTERTOP

CABINET

DRAWER

CABINET

DRAWER PULL

BACKSPLASH

CABINET BACK

CAULKING

SIDESPLASH @

ADJACENT WALL

WHERE OCCURS

CABINET

DRAWER

2' - 1"

4" 1'

/2

2'

U

N

LE

S S

N O

T E

D O

T H

E R

W

IS

E

UNDER CABINET

LIGHT, SEE ELEC

CABINET DOOR

CABINET DOOR

PULL

CABINET

BACK

1' - 3"

1' - 6"

CUT OPENING

FOR OUTLET

Project No.

Copyright © 2018 LEO A DALY Company

JUNE 8, 2020

Location

Issue Date

Project Number

Drawing Number

Project Title

Checked Drawn

FARMINGDALE, NEW YORK

Dwg. of 70

Office of Design and Construction

Service

U.S. Department of Veterans Affairs

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Revisions: Date:

Drawing Title

Approved:

Phase

Project Director

Building Number

LONG ISLAND NATIONAL CEMETERY

FACILITY RENOVATION,

IMPROVEMENTS, AND REPAIRS

815IC3040FINAL CONSTRUCTION

DOCUMENTSLEO A DALY

(402) 391-8111

ECS MID-ATLANTIC, LLC

(847) 279-0366

O'CONNOR CONSTRUCTION

MANAGEMENT, INC.

(202) 299-0530

FINAL CONSTRUCTION DOCUMENTS SUBMISSION

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

GORDON - The LA Group Joint Venture, LLC

The LA Group 40 Long Alley Saratoga Springs, NY 12866

(518) 587-8100

GORDON

148 S. Queen Street, Suite 201 Martinsburg, WV 25401

(304) 725-8456

003-10229-001

/4

/2

:4

:0

P

M

MAINTENANCE BUILDING - INTERIOR

ELEVATIONS AND DETAILS

AE410

la d c o \s h a re s \p ro je c ts

\0 \0

-1

-0

\4

-0 -P ro d u c ti o n -W o rk in g \4

-1 -B

IM

-C

A D

\R e v it V

A N

C L I_

M A

IN

T

-A rc h it e c tu re .r v t

P ro je ct

S ta tu s

SCALE: 1/2" = 1'-0"

TOILET FIXTURE AND ACCESSORIES

SCALE: 1/2" = 1'-0"

ACCESSIBLE LAVATORY CLEARANCE

SCALE: 1/4" = 1'-0"

C3

WOMEN'S RESTROOM 106B - NORTH

SCALE: 1/4" = 1'-0"

C4

WOMEN'S RESTROOM 106B- EAST

SCALE: 1/4" = 1'-0"

C5

WOMEN'S RESTROOM 106B- SOUTH

SCALE: 1/4" = 1'-0"

C7

WOMEN'S RESTROOM 106B - WEST

SCALE: 1/4" = 1'-0"

D5

WOMEN'S LOCKER 106A - SOUTH

SCALE: 1/4" = 1'-0"

C8

MEN'S RESTROOM 108B - NORTH

SCALE: 1/4" = 1'-0"

C9

MEN'S RESTROOM 108B - EAST

SCALE: 1/4" = 1'-0"

D3

MEN'S RESTROOM 108B - SOUTH

SCALE: 1/4" = 1'-0"

D4

MEN'S RESTROOM 108B - WEST

SCALE: 1/4" = 1'-0"

D8

KITCHEN 102 - EAST

SCALE: 1/4" = 1'-0"

D9

KITCHEN 102 - WEST

SCALE: 1/4" = 1'-0"

D6

MEN'S LOCKER 108A - SOUTH

SCALE: 1 1/2" = 1'-0"

F1

TYPICAL UPPER CABINET

SCALE: 1 1/2" = 1'-0"

F3

TYPICAL BASE CABINET W/ SINK

SCALE: 1/2" = 1'-0"

ACCESSIBLE TRANSFER SHOWER

SCALE: 1 1/2" = 1'-0"

F5

TYPICAL BASE CABINET W/ ONE DRAWER

SCALE: 1 1/2" = 1'-0"

F7

BASE CABINET W/ 3 DRAWERS

SCALE: 1 1/2" = 1'-0"

F2

UPPER CABINET MICROWAVE SHELF

BFH SLF

2'

SCALE : 1/4" = 1'-0"

0 4' 8'

1/2'

SCALE : 1 1/2" = 1'-0"

0 1' 1 1/2' çt

Htr

JOINT

REINFORCEMENT

NON-RATED PARTITION UL-U914 OR RATED PARTITION

GWB ON 2" METAL

FURRING

12" CMU TO STRUCTURE

W/ 5/8" GWB ON 4" METAL FURRING

@ 16" OC VERT ONE FACE ONLY

M12O6" CMU TO STRUCTUREM6

LINE OF

STRUCTURE

LINE OF

FLOOR

JOINT

REINFORCEMENT

LINE OF

STRUCTURE

LINE OF

FLOOR

PARTITION TYPE SYMBOL

PARTITION DESIGNATION 3M6C

FIRE

RATING

MATERIAL

NOMINAL

THICKNESS ** OPTION(S) ***

- 1 HR

- 2 HR

- 3 HR

- STUDS

- CMU

- CONCRETE

S

M

C

A

B

C

SUGGESTED

OPTIONS LIST

A - ACOUSTICAL INSULATION

B - BOTH FACES

C - GWB TO 6" ABOVE CEILING

D - DOUBLE WALL

H - SHAFTWALL

L - LEAD LINED

O - ONE FACE ONLY

P - PARTIAL HEIGHT PARTITION

R - RIGID INSULATION W/ GWB COVERING

S - SMOKE PARTITION / BARRIER

T - TEMPORARY PARTITION

Z - STAGGERED STUDS (ACOUSTICAL)

2 - 2 LAYERS GWB

* - DESIGNATION NOT INDICATED FOR NON-RATED PARTITIONS

** - DESIGNATION NOT INDICATED FOR PROJECT STANDARD

THICKNESS

*** - DESIGNATION NOT INDICATED IF OPTIONS ARE NOT APPLICABLE;

ONE OR TWO OPTION DESIGNATORS MAY BE USED.

(or RESILIENT CHANNEL)

- WOOD STUDSW

5/8" GWB

S 3 5/8" METAL STUDS @ 16" OC

W/ 5/8" GWB BOTH SIDES TO

STRUCTURE

NON-RATED PARTITION

SO 3 5/8" METAL STUDS @ 16" OC W/

5/8" GWB ONE FACE ONLY TO

STRUCTURE

OPTION 'O' - ONE GWB FACE ONLY

METAL STUD

5/8" GWB

METAL STUD

S2O 2 1/2" METAL STUDS @ 16" OC W/ 5/8"

GWB ONE FACE ONLY TO

STRUCTURE

LINE OF

STRUCTURE

LINE OF

STRUCTURE

LINE OF

FLOOR

LINE OF

FLOOR

0'

/4

HILTI NO DN24P8 SHOT

PIN OR EQUAL @ 24"

OC & 2" FROM END OF

EACH TRACK SECTION

FLEXIBLE SEALANT

(FR @ SEALANT

RATED CONDITION)

METAL STUDS

FINISHED FLOOR

1 LAYER 5/8" GWB

EACH SIDE

A

SECTION - SILL

0'

/2

M

IN

EXISTING

MASONRY

1/2" MIN

FLEXIBLE

FIRESTOP

SEALANT

DEEP LEG TRACK,

SEISMIC WHERE REQ'D;

DO NOT ATTACH

STUDS OR GWB TO

TOP TRACK

HILTI NO DN24P8 SHOT

PIN OR EQUAL @ 24" OC

AND 2" FROM END OF

EACH TRACK SECTION

METAL FURRING STUDS

RATED MASONRY UNIT OR

CONC WALL

MINERAL WOOL SAFING

(MIN 4 PCF DENSITY)

1/2" MIN FLEXIBLE

FIRESTOP SEALANT

1/4" BENT STL PL

ALTERNATING EACH SIDE

9" LONG @ 4'-0" OC

UL SYSTEM NO HW-D-1009

A

SECTION

MASONRY UNIT

OR CONC WALL

FINISHED

FLOOR

A

SECTION - SILL

REFER TO STRUCTURAL FOR WALL

REINFORCEMENT

Project No.

Copyright © 2018 LEO A DALY Company

JUNE 8, 2020

Location

Issue Date

Project Number

Drawing Number

Project Title

Checked Drawn

FARMINGDALE, NEW YORK

Dwg. of 70

Office of Design and Construction

Service

U.S. Department of Veterans Affairs

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Revisions: Date:

Drawing Title

Approved:

Phase

Project Director

Building Number

LONG ISLAND NATIONAL CEMETERY

FACILITY RENOVATION,

IMPROVEMENTS, AND REPAIRS

815IC3040FINAL CONSTRUCTION

DOCUMENTSLEO A DALY

(402) 391-8111

ECS MID-ATLANTIC, LLC

(847) 279-0366

O'CONNOR CONSTRUCTION

MANAGEMENT, INC.

(202) 299-0530

FINAL CONSTRUCTION DOCUMENTS SUBMISSION

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

GORDON - The LA Group Joint Venture, LLC

The LA Group 40 Long Alley Saratoga Springs, NY 12866

(518) 587-8100

GORDON

148 S. Queen Street, Suite 201 Martinsburg, WV 25401

(304) 725-8456

003-10229-001

/4

/2

:4

:0

P

M

PARTITION TYPES

AE600

la d c o \s h a re s \p ro je c ts

\0 \0

-1

-0

\4

-0 -P ro d u c ti o n -W o rk in g \4

-1 -B

IM

-C

A D

\R e v it V

A N

C L I_

M A

IN

T

-A rc h it e c tu re .r v t

P ro je ct

S ta tu s

SCALE: 1 1/2" = 1'-0"

D8

CMU PARTITION TYPES (PLANS)

SCALE: 1 1/2" = 1'-0"

PARTITION TYPES LEGEND

SCALE: 1 1/2" = 1'-0"

D6

STUD PARTITION TYPES (PLANS)

SCALE: 3" = 1'-0"

F9

STUD PART WALL - NON RATED

SCALE: 3" = 1'-0"

F5

2-HR RATED ASSEMBLY FURRING STUD WALL

SCALE: 3" = 1'-0"

F7

MASONRY PART WALL - NON-RATED

BFH SLF

çt

F

(FLUSH)

FG

(FULL GLASS)

HG

(HALF GLASS)

GLAZING: MG1

F2F1

2" SEE SCH 2"

S E

E S

C H

E D

U

LE

2" SEE SCH 2"

2" S

E E

S C

H E

D U

LE

4"

F3

S E

E S

C H

E D

U

LE

2"

1" SEE SCH 1"

NF

W1 W2

2" 2' - 5" 2"

2" 4'

2"

1'

2"

2" 4'

2"

1'

2"

2" 1' - 5 1/2" 2"

M A

T C

H E

X

IS

T

M A

T C

H E

X

IS

T

2' - 3 1/2" 2' - 3 1/2" 2' - 3 1/2" 2' - 3 1/2"

10' - 0"

2" 2" 2" 2" 2"

2" 2"

1'

2'

W13

2" 2"

2" 1'

1'

2" 1' - 3 1/2"

2" 1' - 3 1/2" 2"

M A

T C

H E

X

IS

T

W11

2" 2'

2"

2" 2" 2" 2' - 6"2' - 6"

W20

8'

TTT

2 1/2" 1' - 1" 2 1/2"

3' - 0"

2 1/2" 1' - 1"

2 1/2"

1/

2" 7'

1/ 2"

W12

2" 10 1/2"

2" 10 1/2" 2"

2" 2"

2" 1'

1'

W21

8'

T

T T

2 1/2" 2 1/2" 2 1/2" 3' - 0"4' - 3 1/2"

1/

2" 1'

/4

1/ 2"

6'

/4

1/

2"

W22

8'

SPANDREL SPANDREL2

1/

2" 2'

1/

4"

1/ 2"

4'

/4

1/

2"

2 1/2" 3' - 7 1/4"

2 1/2" 3' - 7 1/4"

2 1/2"

W23 8'

T T

1/

2" 1'

/4

1/

2" 6'

/4

3/ 4"

2 1/2"

3' - 8 1/4"

2 1/2"

3' - 8 1/4" 2 1/2"

W24

8'

T T

1/

2" 1'

/4

1/ 2"

6'

/4

1/

2"

2 1/2" 2 1/2" 2 1/2" 3' - 8 1/4" 3' - 8 1/4"

W25

8'

T

T

T

1/

2"

1/

2"

1/ 2"

6'

/4

1'

/4

2 1/2" 2 1/2" 2 1/2"

3' - 0" 4' - 4 1/2"

2'

1/ 2"

5'

/2

3' - 1 1/2"

L2

Project No.

Copyright © 2018 LEO A DALY Company

JUNE 8, 2020

Location

Issue Date

Project Number

Drawing Number

Project Title

Checked Drawn

FARMINGDALE, NEW YORK

Dwg. of 70

Office of Design and Construction

Service

U.S. Department of Veterans Affairs

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Revisions: Date:

Drawing Title

Approved:

Phase

Project Director

Building Number

LONG ISLAND NATIONAL CEMETERY

FACILITY RENOVATION,

IMPROVEMENTS, AND REPAIRS

815IC3040FINAL CONSTRUCTION

DOCUMENTSLEO A DALY

(402) 391-8111

ECS MID-ATLANTIC, LLC

(847) 279-0366

O'CONNOR CONSTRUCTION

MANAGEMENT, INC.

(202) 299-0530

FINAL CONSTRUCTION DOCUMENTS SUBMISSION

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

GORDON - The LA Group Joint Venture, LLC

The LA Group 40 Long Alley Saratoga Springs, NY 12866

(518) 587-8100

GORDON

148 S. Queen Street, Suite 201 Martinsburg, WV 25401

(304) 725-8456

003-10229-001

/4

/2

:4

:0

P

M

DOOR AND WINDOW SCHEDULE

AE610

la d c o \s h a re s \p ro je c ts

\0 \0

-1

-0

\4

-0 -P ro d u c ti o n -W o rk in g \4

-1 -B

IM

-C

A D

\R e v it V

A N

C L I_

M A

IN

T

-A rc h it e c tu re .r v t

P ro je ct

S ta tu s

DOOR SCHEDULE

DOOR

NO.

DOOR

HDWE

SET

DOOR FRAME

LABEL

HOUR REMARKSWIDTH HEIGHT TYPE MAT'L FIN. TYPE MAT'L FIN.

DET

NOS

DET

SHT

103A 3' - 0" 7' - 0" 9 F HM P-1F F1 HM P-1F -- NEW DOOR AND FRAME IN NEW OPENING

103B 2' - 8" 7' - 0" 9 F HM P-1F F1 HM P-1F -- EXISTING TO REMAIN

105A 3' - 0" 7' - 0" 10 F HM P-1F F2 HM P-1F -- NEW DOOR AND FRAME IN EXISTING OPENING

105B 3' - 0" 7' - 0" 10 F HM P-1F F2 HM P-1F -- NEW DOOR AND FRAME IN EXISTING OPENING

106A 3' - 0" 7' - 0" 8 F HM P-1F F1 HM P-1F -- NEW DOOR AND FRAME IN NEW OPENING

106B 3' - 0" 7' - 0" 11 F HM P-1F F1 HM P-1F -- NEW DOOR AND FRAME IN NEW OPENING

107 PR

5' - 8" 7' - 1" 4 F/F HM P-1F F2 HM P-1F -- UNEVEN PAIR W/ 3'-0" LEAF AND 2'-8" LEAF, NEW DOOR AND

FRAME IN EXISTING OPENING, GALVANIZED FRAME

108 2' - 10" 7' - 0" 13 F HM P-1F NF HM P-1F -- NEW DOOR AND FRAME IN EXISTING OPENING

108B 3' - 0" 7' - 0" 5 F HM P-1F F2 HM P-1F -- NEW DOOR AND FRAME IN EXISTING OPENING, GALVANIZED

FRAME

109 3' - 0" 7' - 0" 6 F HM P-1F F2 HM P-1F -- NEW DOOR AND FRAME IN EXISTING OPENING

110A 3' - 0" 7' - 1" 6 F HM P-1F F2 HM P-1F -- NEW DOOR AND FRAME IN EXISTING OPENING, GALVANIZED

FRAME

110B 3' - 0" 7' - 0" 8 F HM P-1F F2 HM P-1F 90 MIN NEW DOOR AND FRAME IN NEW OPENING, GALVANIZED

FRAME

111 3' - 0" 7' - 0" 12 HG HM P-1F F1 HM P-1F -- NEW DOOR AND FRAME IN EXISTING OPENING

112 3' - 0" 7' - 0" 12 HG HM P-1F F2 HM P-1F -- NEW DOOR AND FRAME IN EXISTING OPENING

SCALE: 1/4" = 1'-0"

DOOR TYPES

SCALE: 1/4" = 1'-0"

FRAME TYPES

SCALE: 1/4" = 1'-0"

WINDOW TYPES

DOOR SCHEDULE MATERIAL STORAGE BUILDING

DOOR

NO.

DOOR

HDWE SET

DOOR FRAME LABEL

HOUR REMARKSWIDTH HEIGHT TYPE MAT'L FIN. TYPE MAT'L FIN. DET NOS DET SHT

M01 14' - 0" 22' - 0" BY MFR STEEL P-1F STEEL P-1F --

M02 14' - 0" 22' - 0" BY MFR STEEL P-1F STEEL P-1F --

M03 14' - 0" 22' - 0" BY MFR STEEL P-1F STEEL P-1F --

M04B 3' - 0" 7' - 0" 7 F HM P-1F F1 HM P-1F -- NEW DOOR AND FRAME IN NEW OPENING, GALVANIZED

FRAME

MO4A 14' - 0" 22' - 0" BY MFR STEEL P-1F STEEL P-1F --

DOOR SCHEDULE TOOL SHED

DOOR

NO.

DOOR

HDWE SET

DOOR FRAME LABEL

HOUR REMARKSWIDTH HEIGHT TYPE MAT'L FIN. TYPE MAT'L FIN. DET NOS DET SHT

L02 3' - 0" 7' - 0" 7 F HM P-1F 1 HM P-1F -- NEW DOOR AND FRAME IN NEW OPENING, GALVANIZED

FRAME

L04 3' - 0" 7' - 0" 12 HG HM P-1F F1 HM P-1F -- NEW DOOR AND FRAME IN EXISTING OPENING

L05 3' - 0" 7' - 0" 12 HG HM P-1F F1 HM P-1F -- NEW DOOR AND FRAME IN EXISTING OPENING

L06 3' - 0" 7' - 0" 10 F HM P-1F F2 HM P-1F -- NEW DOOR AND FRAME IN EXISTING OPENING

LO1 PR 5' - 0" 8' - 0" BY MFR F AL Black Anodized

1 HM P-1F --

SCALE: 1/4" = 1'-0"

LOUVER TYPES

BFH SLF

GLAZING: IG2 GLAZING: IG2 & IG3 GLAZING: IG2 GLAZING: IG2

GLAZING: IG2

GLAZING: IG2GLAZING: IG1GLAZING: IG1GLAZING: IG1

W10

GLAZING: IG1GLAZING: IG1

@ LOCKER ROOM: IG4

GLAZING: PG #1

çt

UP

OFFICE

A08

STORAGE

A07

GALLEY

A02

CONFERENCE

ROOM

A01

CORRIDOR

A06

LOUNGE

A03

STORAGE

A04

CLOSET

A09

1. UNLESS NOTED OTHERWISE "UNO", REFER TO FINISH PLANS,

ELEVATIONS, REFLECTED CEILING PLANS , AND/OR DETAILS

FOR EXTENTS OF CHANGES IN FINISHES.

2. FLOORING TRANSITIONS BETWEEN ROOMS SHALL BE AT

CENTERLINE OF DOOR, UNO. SEE IN101 SERIES SHEETS FOR

FLOORING TRANSITION DETAILS.

3. ALL EXPOSED TILE EDGES TO BE FINISHED WITH METAL

TRANSITION STRIP (ES), UNO. SEE FINISH PLANS, ELEVATIONS

AND/OR DETAILS FOR LOCATIONS AND EXTENTS OF

INSTALLATION.

4. SEE FINISH PLANS FOR LOCATIONS OF CORNER GUARDS (CG)

AND ELEVATIONS FOR EXTENTS OF INSTALLATION.

5. SEE FINISH PLANS AND/OR REFLECTED CEILING PLANS FOR

LOCATIONS OF ROLLER SHADES (RS) AND IN500 SERIES

SHEETS FOR INSTALLATION DETAILS.

6. PAINT MISCELLANEOUS METALS P-1, UNO. DO NOT PAINT

OUTLET OR SWITCH COVERS.

7. ALL SOLID SURFACE OUTSIDE CORNERS TO BE MITERED, UNO.

GENERAL FINISH NOTESFINISH LEGEND

CFS-ND

CPT-1

LVT-1

SEE PROJECT MANUAL SPECIFICATIONS AT SECTION 09 06

00 COLOR SCHEDULE FOR ADDITIONAL INFORMATION AND

REQUIREMENTS ON FINISHES. PRODUCTS LISTED BY BASIS

OF DESIGN MANUFACTURER ESTABLISH A STANDARD FOR

QUALITY, STYLE AND COLOR.

CAST IN PLACE CONCRETE, SECTION 033053

CFS-ND SEALED CONCRETE

FINISH CARPENTRY AND CASEWORK, SECTION 06 20 00:

PL-1 PLASTIC LAMINATE WILSONART SAP WALNUT

8221-38

SSM-1 SOLID SURFACE CORIAN SAGEBRUSH

SSM-2 SOLID SURFACE CORIAN COOL GRAY

(WINDOW SILL)

ACOUSTICAL CEILINGS, SECTION 09 51 00:

APC-1 ARMSTRONG 24 X 24 ULTIMA TEGULAR 9/16" GRID,

SUPRAFINE WHITE.

RESILIENT TILE FLOORING, SECTION 09 65 19:

LVT-1 KOLAY FLOORING

RESILIENT BASE AND ACCESSORIES, SECTION 09 65 13

RB-1 TARKETT JOHNSONITE NO. 20 CHARCOAL,

SIZE 4"

CARPET TILE, SECTION 09 68 00:

CPT-1 INTERFACE PATTERN: GRASMERE 102848

SLATE

CPT-2 INTERFACE PATTERN: FRENCH SEAMS 105604

CHANTILLY

INTERIOR PAINT, SECTION 09 91 00:

P-1 SHERWIN WILLIAMS AESTHETIC WHITE SW7035

P-2 SHERWIN WILLIAMS KILIM BEIGE SW3106

P-3 SHERWIN WILLIAMS SEA SERPENT SW7615

P-4 SHERWIN WILLIAMS GRIZZLE GRAY SW7068

CPT-2

Project No.

Copyright © 2018 LEO A DALY Company

JUNE 8, 2020

Location

Issue Date

Project Number

Drawing Number

Project Title

Checked Drawn

FARMINGDALE, NEW YORK

Dwg. of 70

Office of Design and Construction

Service

U.S. Department of Veterans Affairs

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Revisions: Date:

Drawing Title

Approved:

Phase

Project Director

Building Number

LONG ISLAND NATIONAL CEMETERY

FACILITY RENOVATION,

IMPROVEMENTS, AND REPAIRS

815IC3040FINAL CONSTRUCTION

DOCUMENTSLEO A DALY

(402) 391-8111

ECS MID-ATLANTIC, LLC

(847) 279-0366

O'CONNOR CONSTRUCTION

MANAGEMENT, INC.

(202) 299-0530

FINAL CONSTRUCTION DOCUMENTS SUBMISSION

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

GORDON - The LA Group Joint Venture, LLC

The LA Group 40 Long Alley Saratoga Springs, NY 12866

(518) 587-8100

GORDON

148 S. Queen Street, Suite 201 Martinsburg, WV 25401

(304) 725-8456

003-10229-001

/4

/2

:4

:4

P

M

FINISH PLAN - ADMINISTRATION BUILDING

IN101

la d c o \s h a re s \p ro je c ts

\0 \0

-1

-0

\4

-0 -P ro d u c ti o n -W o rk in g \4

-1 -B

IM

-C

A D

\R e v it V

A N

C L I_

A D

M

IN

I- A rc h it e c tu re .r v t

P ro je ct

S ta tu s

SCALE: 1/4" = 1'-0"

FINISH PLAN - ADMINISTRATION BUILDING

ROOM FINISH SCHEDULE - ADMINSTRATIVE BUILDING

ROOM

NO. ROOM NAME FLOOR BASE

WALLS

CEILING REMARKSNORTH EAST SOUTH WEST

LEVEL 1

A01 CONFERENCE ROOM CPT-2 RB-1 P-1 P-1 P-3 P-1 APC-1

A02 GALLEY LVT-1 RB-1 P-1 P-1 P-1 P-1 APC-1

A03 LOUNGE LVT-1 RB-1 P-1 P-1 P-1 P-1 APC-1

A04 STORAGE CFS-ND RB-1 P-1 P-1 P-1 P-1 EXISTING

A06 CORRIDOR CPT-1 RB-1 P-1 P-1 P-1 P-1 APC-1

A07 STORAGE CFS-ND RB-1 P-1 P-1 P-1 P-1 EXISTING

A08 OFFICE CPT-1 RB-1 P-3 P-1 P-1 P-1 APC-1

A09 CLOSET CFS-ND RB-1 P-1 P-1 P-1 P-1 EXISTING

DLH TTT

N çt

E

D

C

B

3 4 5 6

MECHANICAL

KEY CONTROL

OFFICE

INTERMENT OFFICE

OPEN OFFICE

KITCHEN

BREAK ROOM

WOMEN'S

106B

MEN'S LOCKER

108A

MUD ROOM

DATA

103A

JAN

103B

MEN'S

108B

ENTRY

CORRIDOR

WOMEN'S

LOCKER

106A

CORRIDOR

C.5

7 8

STORM SHELTER

FINISH LEGEND

CFS-ND

SEE PROJECT MANUAL SPECIFICATIONS AND SECTION 09 06 00 COLOR

SCHEDULE FOR ADDITIONAL INFORMATION AND REQUIREMENTS ON FINISHES.

PRODUCTS LISTED BY BASIS OF DESIGN MANUFACTURER ESTABLISH A

STANDARD FOR QUALITY, STYLE AND COLOR.

CAST IN PLACE CONCRETE, SECTION 033053

CFS-ND SEALED CONCRETE

FINISH CARPENTRY AND CASEWORK, SECTION 06 20 00:

PL-1 PLASTIC LAMINATE WILSONART SAP WALNUT 8221-38

SSM-1 SOLID SURFACE CORIAN SAGEBRUSH

SSM-2 SOLID SURFACE CORIAN COOL GRAY (WINDOW SILL)

ACOUSTICAL CEILINGS, SECTION 09 51 00:

APC-1 ARMSTRONG 24 X 24 ULTIMA TEGULAR 9/16" GRID, SUPRAFINE WHITE.

RESILIENT BASE AND ACCESSORIES, SECTION 09 65 13

RB-1 TARKETT JOHNSONITE NO. 20 PEBBLE, SIZE 4"

INTERIOR PAINT, SECTION 09 91 00:

P-1 SHERWIN WILLIAMS AESTHETIC WHITE SW7035

P-2 SHERWIN WILLIAMS KILIM BEIGE SW3106

P-3 SHERWIN WILLIAMS SEA SERPENT SW7615

P-4 SHERWIN WILLIAMS GRIZZLE GRAY SW7068

N

Project No.

Copyright © 2018 LEO A DALY Company

JUNE 8, 2020

Location

Issue Date

Project Number

Drawing Number

Project Title

Checked Drawn

FARMINGDALE, NEW YORK

Dwg. of 70

Office of Design and Construction

Service

U.S. Department of Veterans Affairs

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Revisions: Date:

Drawing Title

Approved:

Phase

Project Director

Building Number

LONG ISLAND NATIONAL CEMETERY

FACILITY RENOVATION,

IMPROVEMENTS, AND REPAIRS

815IC3040FINAL CONSTRUCTION

DOCUMENTSLEO A DALY

(402) 391-8111

ECS MID-ATLANTIC, LLC

(847) 279-0366

O'CONNOR CONSTRUCTION

MANAGEMENT, INC.

(202) 299-0530

FINAL CONSTRUCTION DOCUMENTS SUBMISSION

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

GORDON - The LA Group Joint Venture, LLC

The LA Group 40 Long Alley Saratoga Springs, NY 12866

(518) 587-8100

GORDON

148 S. Queen Street, Suite 201 Martinsburg, WV 25401

(304) 725-8456

003-10229-001

/4

/2

:4

:0

P

M

MAINTENANCE BUILDING - FINISH PLAN AND

SCHEDULE

IN102

la d c o \s h a re s \p ro je c ts

\0 \0

-1

-0

\4

-0 -P ro d u c ti o n -W o rk in g \4

-1 -B

IM

-C

A D

\R e v it V

A N

C L I_

M A

IN

T

-A rc h it e c tu re .r v t

P ro je ct

S ta tu s

SCALE: 1/4" = 1'-0"

FINISH PLAN - MAINTENANCE BUILDING

ROOM FINISH SCHEDULE

ROOM

NO. ROOM NAME FLOOR BASE

WALLS

CEILING REMARKSNORTH EAST SOUTH WEST

LEVEL 1

100 STORM SHELTER

101 ENTRY CFS-ND RB-1 P-1 P-1 P-1 P-1 APC-1

102 KITCHEN CFS-ND RB-1 P-1 P-1 P-1 P-2 APC-1

103 MUD ROOM CFS-ND RB-1 P-1 P-1 P-1 P-1 APC-1

103A DATA CFS-ND RB-1 P-1 P-1 P-1 P-1 APC-1

103B JAN CFS-ND RB-1 P-1 P-1 P-1 P-1 APC-1

104 BREAK ROOM CFS-ND RB-1 P-1 P-3 P-1 P-1 APC-1

105 CORRIDOR CFS-ND RB-1 P-1 P-1 P-1 P-1 APC-1

105 CORRIDOR CFS-ND RB-1 P-1 P-1 P-1 P-1 APC-1

106A WOMEN'S LOCKER CFS-ND RB-1 P-1 P-1 P-1 P-1 GWB, P-5

106B WOMEN'S CFS-ND PT-2 PT-2 PT-2 PT-2 PT-2 GWB, P-5

107 MECHANICAL CFS-ND RB-1 P-1 P-1 P-1 P-1 EXP. STR,

P-5

108A MEN'S LOCKER CFS-ND RB-1 P-1 P-1 P-3 P-1 GWB, P-5

108B MEN'S CFS-ND PT-2 PT-2 PT-2 PT-2 PT-2 GWB, P-5

110 OPEN OFFICE CFS-ND RB-1 P-1 P-1 P-1 P-1 APC-1

111 KEY CONTROL OFFICE CFS-ND RB-1 P-1 P-1 P-1 P-1 APC-1

112 INTERMENT OFFICE CFS-ND RB-1 P-1 P-1 P-1 P-1 APC-1

M01 BAY 1 CFS-ND RB-1 CONC,

FRP

CONC,

FRP

CONC,

FRP

CONC,

FRP

EXP. STR,

P-5

M02 BAY 2 CFS-ND RB-1 CONC,

FRP

CONC,

FRP

CONC,

FRP

CONC,

FRP

EXP. STR,

P-5

M03 BAY 3 CFS-ND RB-1 CONC,

FRP

CONC,

FRP

CONC,

FRP

CONC,

FRP

EXP. STR,

P-5

MO4 BAY 4 CFS-ND RB-1 CONC,

FRP

CONC,

FRP

CONC,

FRP

CONC,

FRP

EXP. STR,

P-5

T01 TOOL STORAGE CFS-ND RB-1 P-1 P-1 P-1 P-1 EXP. STR,

P-5

DLH TTT

2'

SCALE : 1/4" = 1'-0"

0 4' 8' çt

OFFICE

A08

STORAGE

A07

GALLEY

A02

CONFERENCE

ROOM

A01

CORRIDOR

A06

LOUNGE

A03

STORAGE

A04

CLOSET

A09

A1

T1

T1

T1

T1

T1

T1

T1 T1

C1

C1

C1

C1

C1

C1

C1

C1

C1

C1

C1

C1

C1

C1

C1

C1

C2 C2 C2WS1 WS1 WS1

C1

C1 C1

C1

C1

C1

C1

C1

C1 C1

C1

C1

C1

C1

C1C1

C1 C1

C1 C1

C1 C1

C1 C1

C1

C1

FURNISHED / INSTALLED LEGEND

CFCI CONTRACTOR FURNISHED, CONTRACTOR

INSTALLED

OFOI

OFCI

OWNER FURNISHED, OWNER INSTALLED

OWNER FURNISHED, CONTRACTOR INSTALLED

Project No.

Copyright © 2018 LEO A DALY Company

JUNE 8, 2020

Location

Issue Date

Project Number

Drawing Number

Project Title

Checked Drawn

FARMINGDALE, NEW YORK

Dwg. of 70

Office of Design and Construction

Service

U.S. Department of Veterans Affairs

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Revisions: Date:

Drawing Title

Approved:

Phase

Project Director

Building Number

LONG ISLAND NATIONAL CEMETERY

FACILITY RENOVATION,

IMPROVEMENTS, AND REPAIRS

815IC3040FINAL CONSTRUCTION

DOCUMENTSLEO A DALY

(402) 391-8111

ECS MID-ATLANTIC, LLC

(847) 279-0366

O'CONNOR CONSTRUCTION

MANAGEMENT, INC.

(202) 299-0530

FINAL CONSTRUCTION DOCUMENTS SUBMISSION

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

GORDON - The LA Group Joint Venture, LLC

The LA Group 40 Long Alley Saratoga Springs, NY 12866

(518) 587-8100

GORDON

148 S. Queen Street, Suite 201 Martinsburg, WV 25401

(304) 725-8456

003-10229-001

/4

/2

:4

:4

P

M

FURNITURE PLAN - ADMINISTRATION

BUILDING

IF101

la d c o \s h a re s \p ro je c ts

\0 \0

-1

-0

\4

-0 -P ro d u c ti o n -W o rk in g \4

-1 -B

IM

-C

A D

\R e v it V

A N

C L I_

A D

M

IN

I- A rc h it e c tu re .r v t

P ro je ct

S ta tu s

SCALE: 1/4" = 1'-0"

FURNITURE PLAN

FF&E SCHEDULE

Type Mark JSN Number Description Furnished by

A1 R7000 Refrigerator CFCI

C1 F0205 HON - Motivate - Nesting/Stacking Flex-Back Chairs - Chair OFCI

C2 F0300 HON Ignition Work Mid-Back OFCI

T1 F0860 HON - Between - Nesting Tables - Rectangular Nesting Tables - 72 " W x 30" D

OFCI

WS1 E0075 HON Metro Classic L-Shaped Workstation OFCI

DLH TTT

N çt

E

D

C

B

3 4 5 6

MECHANICAL

KEY CONTROL

OFFICE

INTERMENT OFFICE

OPEN OFFICE

KITCHEN

BREAK ROOM

WOMEN'S

106B

MEN'S LOCKER

108A

MUD ROOM

DATA

103A

JAN

103B

WOMEN'S

LOCKER

106A

MEN'S

108B

ENTRY

CORRIDOR

CORRIDOR

4' - 4"

C2

A1

A1

C2

C2

C2

C2 C2

C2

C2

C3

C3

T2

C3

C3 C3 C3

C3C3

T2

C3

T2

C3

C3

C3

C3

C3

T2 C3

C3 C3

T2

C3

C3C3

T3

WS1

WS1

WS1

WS1

WS1

WS1

T4

T4

T4

WS2

WS2

C.5

7 8

STORM SHELTER

A2

A2

A2

N

Project No.

Copyright © 2018 LEO A DALY Company

JUNE 8, 2020

Location

Issue Date

Project Number

Drawing Number

Project Title

Checked Drawn

FARMINGDALE, NEW YORK

Dwg. of 70

Office of Design and Construction

Service

U.S. Department of Veterans Affairs

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Revisions: Date:

Drawing Title

Approved:

Phase

Project Director

Building Number

LONG ISLAND NATIONAL CEMETERY

FACILITY RENOVATION,

IMPROVEMENTS, AND REPAIRS

815IC3040FINAL CONSTRUCTION

DOCUMENTSLEO A DALY

(402) 391-8111

ECS MID-ATLANTIC, LLC

(847) 279-0366

O'CONNOR CONSTRUCTION

MANAGEMENT, INC.

(202) 299-0530

FINAL CONSTRUCTION DOCUMENTS SUBMISSION

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

GORDON - The LA Group Joint Venture, LLC

The LA Group 40 Long Alley Saratoga Springs, NY 12866

(518) 587-8100

GORDON

148 S. Queen Street, Suite 201 Martinsburg, WV 25401

(304) 725-8456

003-10229-001

/4

/2

:4

:0

P

M

MAINTENANCE BUILDING - FURNITURE PLAN

IF102

la d c o \s h a re s \p ro je c ts

\0 \0

-1

-0

\4

-0 -P ro d u c ti o n -W o rk in g \4

-1 -B

IM

-C

A D

\R e v it V

A N

C L I_

M A

IN

T

-A rc h it e c tu re .r v t

P ro je ct

S ta tu s

SCALE: 1/4" = 1'-0"

FURNITURE PLAN - MAINTENANCE BUILDING

FF&E SCHEDULE

Type Mark JSN Number Description Furnished By

A1 R7000 Refrigerator CFCI

A2 K4660 Microwave Oven CFCI

C2 F0300 HON Ignition Work Mid-Back OFCI

C3 F0295 HON - Motivate - High-Density Sled Base Chairs - High-Density Stacker

OFCI

L1 A1035 Lockers CFCI

T2 F0795 HON - Between - Table Top - Round Table Tops - 42" W OFCI

T3 F0750 AGL Table Rectangular Pntd Formcoat Top 38D 75W OFCI

T4 F0799 Picnic Table OFCI

WS1 E0075 HON Metro Classic L-Shaped Workstation OFCI

WS2 E0075 HON Metro Classic L-Shaped Workstation OFCI

DLH TTT

2'

SCALE : 1/4" = 1'-0"

0 4' 8' çt

1. INSTALLATION SHALL MEET ALL REQUIREMENTS OF THE

AMERICAN WITH DISABILITIES ACT (ADA). ADA REQUIREMENT

WILL OVERRULE PLAQUE DETAILS SHOWN IF IN CONFLICT.

2. INSTALLATION SHALL MEET ALL LOCAL, STATE, FEDERAL

BUILDING AND SAFETY CODES.

3. ALL SIGNS SHALL BE INSTALLED LEVEL AND PLUMB TO WITHIN

1/64" PER FOOT OF LENGTH AND AT A CONSISTANT HEIGHT.

4. HANGING AND FLAG SIGNS MUST REMAIN 24" FROM

SPRINKLER HEADS.

5. SIGNS CANNOT VISUALLY BLOCK ILLUMINATED "EXIT" SIGNS.

EXIT SIGNS MUST BE VISUALLY UNOBSTRUCTED FROM A

DISTANCE OF 100 FEET.

6. LOCATIONS MAY VARY UP TO 1/2" LEFT OR RIGHT OF

DESIGNATION UNLESS FIELD CONDITIONS REQUIRE FURTHER

MODIFICATION.

7. LOCATIONS UNABLE TO BE INSTALLED IN DESIGNATED AREAS

TO BE RELOCATED FOLLOWING REVIEW BY ARCHITECT, SIGN

PLANNER OR DESIGNATED FACILITY STAFF OR

REPRESENTATIVE.

8. CLEAR SILICON ADHESIVE CAULK TO BE ADDED INSIDE TAPE

AREA AT A MINIMUM OF 2 LOCATIONS. NO SILICONE TO BE

VISIBLE AROUND EDGES OF SIGN.

9. SIGNS UNABLE TO ACHIEVE ADA REQUIRED HEIGHT LOCATION

SHALL BE PLACED LOWER THAN THE 60" CENTERLINE

DESIGNATION.

10. SIGNS UNABLE TO ACHIEVE ADA STANDARD LATCH POSITION

CAN BE PLACED AT HINGE LOCATION OR BE POSITIONED UP

TO 2" FROM FRAME. CORNER LOCATIONS CAN BE MODIFIED

TO NEAREST INSIDE WALL AT KNOB SIDE OF FRAME. TACTILE

SIGNS SHOULD NOT BE PLACED ON DOOR AS AN ALTERNATIVE

LOCATION UNLESS DESIGNATED ON PLAN OR IN SCHEDULE.

11. COORDINATE MOUNTING LOCATIONS WITH SIGNAGE PLANS.

12. SIGNAGE NAMES AND NUMBERING TO BE VERIFIED PRIOR TO

FABRICATION BY CONTRACTING OFFICER.

13. SEE SPECIFICATION SECTION 10 14 05 FOR FULL SIGNAGE

SPECIFICATIONS.

14. SIGNAGE NAMES AND NUMBERING TO BE VERIFIED BY OWNER

PRIOR TO FABRICATION.

GENERAL SIGNAGE NOTES

F

E

D

C

B

3 4 5 6

NC-14.01

NC-14.01

NC-15.02

NC-15.01

NC-16.04

MECHANICAL

KEY CONTROL

OFFICE

INTERMENT OFFICE

OPEN OFFICE

KITCHEN

BREAK ROOM

WOMEN'S

106B

MEN'S LOCKER

108A

MUD ROOM

DATA

103A

JAN

103B

WOMEN'S

LOCKER

106A

MEN'S

108B

ENTRY

CORRIDOR

CORRIDOR

C.5

7 8

STORM SHELTER

NC-15.01-2

ADA/ABA COMPLIANT

RESTROOM IDENTIFICATION

NC-14.01

PRIMARY ROOM IDENTIFICATION

0'

0' - 6"

NC-16.04

NO SMOKING SIGN

N

Project No.

Copyright © 2018 LEO A DALY Company

JUNE 8, 2020

Location

Issue Date

Project Number

Drawing Number

Project Title

Checked Drawn

FARMINGDALE, NEW YORK

Dwg. of 70

Office of Design and Construction

Service

U.S. Department of Veterans Affairs

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

Revisions: Date:

Drawing Title

Approved:

Phase

Project Director

Building Number

LONG ISLAND NATIONAL CEMETERY

FACILITY RENOVATION,

IMPROVEMENTS, AND REPAIRS

815IC3040FINAL CONSTRUCTION

DOCUMENTSLEO A DALY

(402) 391-8111

ECS MID-ATLANTIC, LLC

(847) 279-0366

O'CONNOR CONSTRUCTION

MANAGEMENT, INC.

(202) 299-0530

FINAL CONSTRUCTION DOCUMENTS SUBMISSION

VA FORM 08 - 6231

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

GORDON - The LA Group Joint Venture, LLC

The LA Group 40 Long Alley Saratoga Springs, NY 12866

(518) 587-8100

GORDON

148 S. Queen Street, Suite 201 Martinsburg, WV 25401

(304) 725-8456

003-10229-001

/4

/2

:4

:0

P

M

MAINTENANCE BUILDING - SIGNAGE PLAN

IX102

la d c o \s h a re s \p ro je c ts

\0 \0

-1

-0

\4

-0 -P ro d u c ti o n -W o rk in g \4

-1 -B

IM

-C

A D

\R e v it V

A N

C L I_

M A

IN

T

-A rc h it e c tu re .r v t

P ro je ct

S ta tu s

SCALE: 1/4" = 1'-0"

SIGNAGE PLAN - MAINTENANCE BUILDING

SCALE: 3" = 1'-0"

SIGNAGE DETAIL

DLH TTT

2'

SCALE : 1/4" = 1'-0"

0 4' 8' çt

CAPACITOR

DESCRIPTIONSYMBOL

CIRCUIT BREAKER

MOTOR STARTER, # INDICATES NEMA STARTER SIZE

CURRENT TRANSFORMER

POTENTIAL TRANSFORMER

DRAWOUT CIRCUIT BREAKER

FUSE

GROUND CONNECTION

GENERATOR

KIRK KEY INTERLOCK

LIGHTNING ARRESTOR

MAGENTIC MOTOR STARTER

METER (AS SPECIFIED)

SWITCH

TRANSFER SWITCH, AUTOMATIC UON

TRANSFORMER

ATS BYPASS

SOLID-STATE MULTI-FUNCTION METER

TRANSFORMER CONFIGURATION

TRANSFORMER CONFIGURATION

AMMETER AND PHASE SELECTOR SWITCH

VOLTMETER AND PHASE SELECTOR SWITCH

PANELBOARD

PREWIRED CONTROL PANEL

SURGE PROTECTIVE DEVICE

DISCONNECT SWITCH

3 WIRE FEEDER TAG

4 WIRE FEEDER TAG

EMERGENCY POWER FEEDER

CT

PT

G

G F P GROUND FAULT PROTECTOR

K

M

3 CT

AAS

VVS

X-X

TRANSIENT VOLTAGE SURGE SUPPRESSION

PWCP

SPD

TVSS

E

ONE-LINE DIAGRAM

DESCRIPTIONSYMBOL

LIGHT FIXTURES

STANDARD SYMBOL INDICATES NORMAL POWER

FULL HATCHED SYMBOL INDICATES EGRESS LIGHTING CODE

REQUIRED LIFE SAFETY ILLUMINATION OF EGRESS PATH

HALF-SHADED SYMBOL INDICATES EMERGENCY LIGHTING

NON-LIFE SAFETY LIGHTING REQUIRING BACKUP POWER

LIGHT FIXTURE LABELING

A1 a

"A1" INDICATES FIXTURE TYPE

"a" INDICATES CONTROL SWITCHBOARD

"1" INDICATES CIRCUIT NUMBER

INDICATES DIRECTIONAL LIGHTING

RECTANGULAR LUMINAIRE

ROUND LUMINAIRE

LINEAR LUMINAIRE

WALL MOUNTED LINEAR LUMINAIRE

STRIP LUMINAIRE

WALL MOUNTED LUMINAIRE

UNDER CABINET LUMINAIRE

COVE LIGHTING

TRACK LIGHTING, QUANTITY AND ORIENTATION AS SHOWN

SPECIALTY FIXTURE

EXIT SIGN, CEILING OR WALL MOUNT

EMERGENCY LIGHTING UNIT

POLE MOUNTED LIGHTING (HEADS AS INDICATED)

POLE MOUNTED LIGHTING MULTI-HEAD

POLE MOUNTED LIGHTING POST TOP HEAD

BOLLARD LUMINAIRE

FLOOD LIGHTING

IN-GRADE LIGHTING

DESCRIPTIONSYMBOL

SWITCHING AND CONTROL OUTLETS

SINGLE POLE, TOGGLE

TWO SINGLE POLE, TOGGLE, INDICATES BY-LEVEL SWITCHING

PUSH BUTTON, 48" A.F.F. UON

DAYLIGHT SENSOR, ON CEILING

OCCUPANCY SENSOR, ON CEILING

PHOTO CELL CONTROL, ON CEILING

POWER PACK FOR OCCUPANCY SENSORS

DS

OS

PC

PP

a

SWITCH LABELING

"a" INDICATES FIXTURES OR BALLAST CONTROLLED BY

SWITCH

"1" INDICATES SWITCH TYPE AS BELOW:

2 = DOUBLE POLE, SINGLE THROW K = KEY OPERATED

3 = THREE WAY M = MOTOR RATED

4 = FOUR WAY MC = MOMENTARY CONTACT

D = DIMMER O = OCCUPANCY SENSOR

P = INTERNAL PILOT LIGHT T = TIMER

TS= TIME SWITCH V = VACANCY SENSOR

LV= LOW VOLTAGE TE= THERMAL ELEMENT

DESCRIPTIONSYMBOL

TELECOMMUNICATION

VOICE OUTLET

DATA OUTLET

VOICE/DATA OUTLET

SAME AS INDICATED ABOVE EXCEPT CIRCULAR SYMBOLS

INDICATE FLUSH MOUNTED IN CEILING AND SQUARE SYMBOLS

INDICATE FLUSH MOUNTED IN FLOOR

CABLE TRAY - TYPE/SIZE AS INDICATED ON PLANS

WAP

DAS

WIRELESS ACCESS POINT

DISTRIBUTED ANTENNA SYSTEM ANTENNA

TELECOMMUNICATIONS CABINET

TELECOMMUNICATIONS RACK

TELECOMMUNICATIONS GROUND BAR

TELECOMMUNICATIONS MAIN GROUND BAR

TGB

TMGB

TELEVISION OUTLET, ON CEILING

TELEVISION OUTLET, WALL MOUNTED 60" A.F.F. UON

DUPLEX RECEPTACLE

DESCRIPTIONSYMBOL

DUPLEX RECEPTACLE, FLUSH MOUNTED ON CEILING

DUPLEX RECEPTACLE, FLUSH MOUNTED IN FLOOR

DOUBLE DUPLEX RECEPTACLE

DOUBLE DUPLEX RECEPTACLE, FLUSH MOUNTED ON CEILING

DOUBLE DUPLEX RECEPTACLE, FLUSH MOUNED IN FLOOR

POWER OUTLETS

DUPLEX RECEPTACLE, EMERGENCY POWER

DOUBLE DUPLEX RECEPTACLE, EMERGENCY POWER

DUPLEX RECEPTACLE, SWITCHED

DOUBLE DUPLEX RECEPTACLE, SWITCHED

SINGLE RECEPTACLE

SINGLE RECEPTACLE, EMERGENCY POWER

SPECIAL RECEPTACLE, AS NOTED

WALL CLOCK RECEPTACLE, 90" A.F.F. UONC

MULTI-OUTLET ASSEMBLY, AS NOTED

DESCRIPTIONSYMBOL

POWER DISTRIBUTION

WIRING IDENTIFICATION

LETTER INDICATES PANEL, NUMBERS INDICATE CIRCUITS

CONDUIT CONCEALED IN CEILING OR WALL

CONDUIT DOWNWARD

CONDUIT UPWARD

CONDUIT CONTINUATION

CONDUIT IN DUCTBANK

SURFACE MOUNTED BRANCH PANELBOARD

FLUSH MOUNTED BRANCH PANELBOARD

DISTRIBUTION PANEL

SWITCHBOARD

MOTOR CONTROL CENTER

ELECTRICAL CABINET OR SPECIAL PURPOSE ENCLOSURE

PULL BOX

MANHOLE

HANDHOLE

AUTOMATIC TRANSFER SWITCH

SURGE PROTECTION DEVICE

A-1,3,5

CONDUIT EXPOSED

CONDUIT CONCEALED IN FLOOR OR BELOW GRADE

CONDUIT SEAL

CDB

PB

MH

HH

ATS

SPD

VARIABLE FREQUENCY DEVICEVFD

MOTOR

NON-FUSED DISCONNECT SWITCH

FUSED DISCONNECT SWITCH

INDIVIDUAL MOLDED CASE CIRCUIT BREAKER IN ENCLOSURE

MAGNETIC MOTOR STARTER

COMBINATION MOTOR STARTER AND DISCONNECT SWITCH

J

J

J

JUNCTION BOX, WALL MOUNTED

JUNCTION BOX, FLUSH MOUNTED ON CEILING

JUNCTION BOX, FLUSH MOUNTED IN FLOOR

CONDUIT END CAP

DESCRIPTIONSYMBOL

FIRE ALARM

F

F

F

F #

S

C

C

DH

M

I

P

S M

F SC

R/F

F°

PIV

TS

FS

ET

FAA

FACP

FMCP

EVAC

BATT

NAC#

MNCP

LOC

MN#

R

M

A

FIRE ALARM MANUAL STATION

FIRE ALARM EXTERIOR BELL (WP)

FIRE ALARM INTERIOR HORN

FIRE ALARM HORN STROBE, # INDICATES CANDELLA RATING

FIRE ALARM SPEAKER STROBE, # INDICATES CANDELLA

RATING

FIRE ALARM STROBE, # INDICATES CANDELLA RATING

FIRE ALARM STROBE, ON CEILING, # INDICATES CANDELLA

RATING

FIRE ALARM STROBE AND CHIME COMBINATION

FIRE ALARM SPEAKER ONLY

FIRE ALARM CHIME

FIRE ALARM DOOR HOLDER

SMOKE DAMPER

FIRE/SMOKE DAMPER

MOTORIZED FIRE/SMOKE DAMPER

FIRE ALARM IONIZATION TYPE SMOKE DETECTOR

FIRE ALARM PHOTOELECTRIC TYPE SMOKE DETECTOR

DUCT SMOKE DETECTOR

FIRE ALARM SMOKE DETECTOR

MASS NOTIFICATION SPEAKER/STROBE, # INDICATES

CANDELLA RATING

MASS NOTIFICATION STROBE, # INDICATES CANDELLA RATING

MASS NOTIFICATION STROBE, ON CEILING, # INDICATES

CANDELLA RATING

MASS NOTIFICATION SPEAKER, # INDICATES DECIBEL RATING

COMBINATION SMOKE AND CARBON MONOXIDE DETECTOR

HEAT DETECTOR COMBINATION FIXED TEMPERATURE AND

RATE OF RISE

HEAT DETECTOR, FIXED TEMPERATURE

GAS DETECTOR/SENSOR, # INDICATES GAS TYPE

POST INDICATOR VALVE

TAMPER SWITCH

FLOW SWITCH

EMERGENCY TEXTUAL VISIBLE APPLIANCE

FIRE ALARM ANNUNCIATOR

FIRE ALARM CONTROL PANEL

FIRE ALARM AND MASS NOTIFICATION SYSTEM CONTROL

PANEL

FIRE ALARM SYSTEM VOICE EVACUATION AUDIO PANEL

FIRE ALARM SYSTEM BATTER PACK/CHARGER CABINET

FIRE ALARM NOTIFICATION APPLIANCE CIRCUIT (NAC)

MASS NOTIFICATION SYSTEM CONTROL PANEL

LOCAL OPERATING CONSOLE

POWER SUPPLY AND INTERFACE TERMINAL CABINET

ABORT SWITCH

MANUAL RELEASING STATION

FIRE ALARM RELAY

ELECTRICAL SYMBOL LEGEND NOTES

1. ALL SYMBOLS INDICATED ARE NOT NECESSARILY USED ON PLANS.

2. ALL MOUNTING DIMENSIONS GIVEN ARE TO THE CENTERLINE (CL) OF THE

DEVICE AND ABOVE FINISHED FLOOR (A.F.F.) OR ABOVE FINISHED GRADE

(A.F.G.) UNLESS OTHERWISE NOTED.

3. WALL MOUNTED LIGHT SWITCHES ARE TO BE LOCATED 46" A.F.F. AND 2"

FROM EDGE OF DOOR FRAME TO EDGE OF DEVICE PLATE.

4. OUTLETS INDICATED AS BEING FOR WALL MOUNTED TELEPHONES SHALL

BE LOCATED 54" A.F.F. UNLESS OTHERWISE NOTED.

5. WALL MOUNTED FIRE ALARM MANUAL PULL STATIONS ARE TO BE

LOCATED 46" A.F.F. AND WITHIN 60" OF THE NEAREST ADJACENT EXIT

DOOR FROM THE FLOOR OR BUILDING.

6. FIRE ALARM VISUAL NOTIFICATION APPLIANCES SHALL BE MOUNTED

SUCH THAT THE ENTIRE LENS IS BETWEEN 80" AND 96" A.F.F..

7. FIRE ALARM CONTROL CABINETS, AND OTHER SIMILAR CABINETS SHALL

BE MOUNTED 72" A.F.F. TO THE TOP.

8. CONVENIENCE OUTLETS SHALL BE MOUNTED 18" A.F.F. AND SHALL BE

ALIGNED VERTICALLY. PROVIDE HORIZONTAL INSTALLATIONS ONLY WHEN

SPACE IS LIMITED, SUCH AS BETWEEN MIRRORS AND CABINET

BACKSLASHES. THE GROUND PIN SHALL BE ORIENTED IN THE UP

POSITION.

9. CONVENIENCE OUTLETS LOCATED IN MECHANICAL AND BOILER ROOMS

SHALL BE LOCATED 46" A.F.F..

10. CONVENIENCE OUTLETS LOCATED OUTSIDE SHALL BE GFI AND

WEATHERPROOF RATED, FURNISHED WITH A WEATHERPROOF "WHILE-IN-

USE" COVER AND MOUNTED 24" A.F.F. OR A.F.G.. EXTERIOR

CONVENIENCE OUTLETS SHALL BE INSTALLED WITHIN 25 FEET AND ON

THE SAME LEVEL AS HEATING, AIR CONDITIONING AND REFRIGERATION

EQUIPMENT.

11. OUTLETS FOR WALL MOUNTED TELECOMMUNICATION OR COMPUTER

DEVICES SHALL BE LOCATED 18" A.F.F. AND SHALL BE ALIGNED

VERTICALLY. PROVIDE HORIZONTAL INSTALLATIONS ONLY WHEN SPACE

IS LIMITED, SUCH AS BETWEEN MIRRORS AND CABINET BACKSLASHES.

12. MISCELLANEOUS WALL MOUNTED CONTROL DEVICES, SUCH AS SPEAKER

VOLUME CONTROLS, DOOR BELLS, AUTOMATIC DOOR PUSH PADS, ETC.

SHALL BE MOUNTED AT 46" A.F.F.

13. WALL MOUNTED LIGHTING FIXTURES SHALL BE MOUNTED AS INDICATED

ON THE DRAWINGS.

14. PANELBOARDS, TELEPHONE PANELS, FIRE ALARM CONTROL CABINETS,

AND OTHER SIMILAR CABINETS SHALL BE MOUNTED 72" A.F.F. TO THE

TOP.

15. MOTOR CONTROLLERS AND SAFETY SWITCHES SHALL BE MOUNTED 60"

A.F.F..

16. CEILING MOUNTED SMOKE DETECTORS SHALL BE LOCATED NO MORE

THAN 30' ON CENTER FROM EACH AND NO MORE THAN 15' FROM THE END

OF A CORRIDOR OR SMOKE PARTITION. SMOKE DETECTORS SHALL ALSO

NOT BE PLACED WITHIN 3' OF SUPPLY OR RETURN AIR DIFFUSERS,

ADJUST SPACING SHOWN ON DRAWINGS AS REQUIRED.

17. DEVICE BOXES SHALL BE MOUNTED FLUSH IN WALLS UNLESS OTHERWISE

NOTED OR REQUIRED. FLUSH SHALL BE DEFINED AS EVEN WITH THE FACE

OF THE WALL, OR RECESSED NO MORE THAN 1/16".

18. WALL BOXES FOR SINGLE AND TWO-GANG SWITCH, CONVENIENCE

OUTLET, OR TELECOMMUNICATIONS OR DATA INSTALLATIONS SHALL BE

4" SQUARE WITH APPROPRIATE SINGLE OR DOUBLE GANG PLASTER

RINGS OF CORRECT DEPTH FOR WALL CONSTRUCTION. SECTIONAL OR

MULTI-GANG BOXES WITH APPROPRIATE PLASTER RINGS SHALL BE USED

FOR MULTI-GANG APPLICATIONS.

19. WHERE DEVICES CONNECTED TO NORMAL AND EMERGENCY POWER

SYSTEMS ARE LOCATED IN THE SAME BOX, PROVIDE LISTED METALIC

BARRIERS AND SEPARATE RACEWAYS. BOXES SHALL BE PROPERLY

CONFIGURED TO ACCEPT BARRIERS.

MOUNTING HEIGHT A.F.F. TO CENTER LINE OF DEVICE

DESCRIPTIONSYMBOL

SUBSCRIPTS

MOUNT DEVICE 6" ABOVE COUNTER OR 36" A.F.F. AT

WORKSTATIONS

DEDICATED

EMERGENCY

EXPLOSION PROOF, CLASS GROUP AND DIVISION AS NOTED

UNIT IS CONNECTED TO FIRE ALARM SYSTEM

GROUND FAULT CIRCUIT INTERRUPTER

HOSPITAL GRADE

ISOLATED GROUND

44"

AC

D

E

EX

FA

G

H

IG

UNSWITCHED NIGHT LIGHT

RAINTIGHT NEMA TYPE 3R OR EQUIVALENT

SURGE PROTECTED TYPE RECEPTACLE

TAMPER-RESISTANT

TELEVISION

CONNECTED TO UPS SYSTEM

WEATHERPROOF NEMA TYPE 3 OR EQUIVALENT

NL

RT

SP

T

TV

U

WP

PAN, TILT, ZOOM TYPE CAMERAPTZ

FIRE ALARM HORN, ON CEILING # INDICATES CANDELLA

RATING

FIRE ALARM HORN STROBE, ON CEILING, # INDICATES

CANDELLA RATING

FIRE ALARM SPEAKER, ON CEILING, # INDICATES CANDELLA

RATING

FIRE ALARM SPEAKER STROBE, ON CEILING # INDICATES

CANDELLA RATING

# MASS NOTIFICATION SPEAKER, ON CEILING, # INDICATES

DECIBEL RATING

# MASS NOTIFICATION SPEAKER STROBE, ON CEILING,

# INDICATES CANDELLA RATING

R RELAY

3/4" PLYWOOD, PAINTED W/ 2 COATS FIRE PROOF GREY PAINT

RECESSED FLOOR DUCT, TYPE/SIZE AS INDICATED ON PLANS

POLE MOUNTED TRANSFORMER

3 PHASE POLE MOUNTED TRANSFORMERS

PUSHBUTTON, NUMBER OF BUTTONS AS SHOWN

DUPLEX RECEPTACLE, HORIZONTAL MOUNT

ELECTRICAL GENERAL NOTES

1. ALL ELECTRICAL WORK SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE APPLICABLE

EDITIONS OF THE NATIONAL ELECTRICAL CODE, THE STATE BUILDING CODE, AND ANY OTHER

LOCAL, STATE, OR FEDERAL CODES, ORDINANCES, OR AUTHORITATIVE INTERPRETATIONS

THAT MAY APPLY. A CERTIFICATE OF FINAL ELECTRICAL INSPECTION SHALL BE OBTAINED BY

THE CONTRACTOR AT THE COMPLETION OF THE WORK AND PRESENTED TO BOTH THE OWNER

AND THE A/E.

2. THE CONTRACTOR SHALL FURNISH AND INSTALL COMPLETE AND SATISFACTORILY OPERATING

SYSTEMS AS INDICATED ON THE CONTRACT DOCUMENTS. IT IS NOTED THAT THE DRAWINGS

ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENTS OF SYSTEMS AND WORK.

CIRCUIT NUMBERS, INTERCONNECTIONS, HOME RUNS, AND SWITCH LEGS HAVE BEEN SHOWN,

AND THE CONTRACTOR SHALL FURNISH AND INSTALL CONDUIT AND WIRING AS REQUIRED TO

ACCOMPLISH THE FUNCTIONS INDICATED. SPECIAL SYSTEMS DEVICES (COMMUNICATIONS,

SECURITY, ETC.) HAVE BEEN SHOWN AND THE CONTRACTOR SHALL FURNISH AND INSTALL THE

REQUIRED QUANTITIES AND TYPES OF CABLES, CONDUCTORS, RACEWAYS, REMOTE POWER

SUPPLIES AND CONNECTIONS, SHIELDING REQUIREMENTS, ETC., AS REQUIRED BY THE SYSTEM

MANUFACTURER, THE SPECIFICATIONS, AND ANY APPLICABLE CODES.

3. THE CONTRACTOR SHALL COORDINATE THE ELECTRICAL WORK WITH THE WORK OF ALL OTHER

TRADES SO AS TO AVOID CONFLICTS. RESOLVE ALL CONFLICTS THROUGH THE A/E PRIOR TO

ROUGH-IN. FAILURE TO PROVIDE SUCH COORDINATION PRIOR TO WORK BEING INSTALLED

SHALL NOT BE CAUSE FOR ADDITIONAL COMPENSATION TO THE CONTRACTOR, AND MAY

RESULT IN REJECTION OF THE WORK. IT IS THE CONTRACTORS' RESPONSIBILITY TO

COORDINATE SUBSTITUTIONS WITH OTHER TRADES.

4. ALL MATERIALS SHALL BE NEW, SHALL BE SUITABLE FOR THE APPLICATION INTENDED, AND

SHALL BEAR LABELS OR MARKINGS INDICATING THIRD PARTY TESTING LABORATORY LISTINGS

ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION UNLESS OTHERWISE NOTED.

5. VERIFY LOCATIONS OF LIGHTING FIXTURES WITH ARCHITECTURAL REFLECTED CEILING PLANS

AND THE PLANS OF ALL OTHER TRADES. COORDINATE FIXTURE RECESSING DEPTHS WITH

MECHANICAL WORK AND COORDINATE ACCORDINGLY.

6. ALL WIRING FOR POWER AND LIGHTING SYSTEMS SHALL BE INSTALLED IN METALLIC RACEWAY

SYSTEMS UNLESS OTHERWISE NOTED. ALL CONDUCTORS SHALL BE COPPER, SHALL BE #

12AWG MINIMUM, AND SHALL HAVE 600V TYPE THHN/THWN INSULATION, UNLESS OTHERWISE

NOTED. ALL RACEWAYS AND CIRCUITS SHALL INCLUDE INSULATED GROUND CONDUCTORS

SIZED AS INDICATED OR AS REQUIRED BY THE NEC. MINIMUM RACEWAY SIZE SHALL BE 3/4"

UNLESS OTHERWISE NOTED.

7. RACEWAYS SHALL NOT CONTAIN MORE THAN THREE PHASE CONDUCTORS, THREE NEUTRALS,

AND ONE GROUND CONDUCTOR, UNLESS OTHERWISE NOTED. CONTRACTOR SHALL PROVIDE

SEPARATE NEUTRALS FOR ALL 20A/1P CIRCUIT BREAKERS. PROVIDING MULTI-POLE CIRCUIT

BREAKERS IN CONJUNCTION WITH SHARED NEUTRALS IN A MULTI-WIRE CIRCUIT IN

ACCORDANCE WITH 2017 NEC 210.4 SHALL REQUIRE APPROVAL BY THE ENGINEER.

8. EXPOSED RACEWAY UP TO 8'-0" ABOVE FINISHED FLOOR OR GRADE ELEVATION, OR ANY

RACEWAY SUBJECT TO DAMAGE, SHALL BE RMC.

9. ALL CONNECTIONS FOR ELECTRICALLY POWERED EQUIPMENT, INCLUDING BUT NOT LIMITED TO

MECHANICAL AND OWNER SUPPLIED EQUIPMENT, SHALL BE FURNISHED AND INSTALLED.

WHERE NOT INDICATED AS BEING PROVIDED WITH THE EQUIPMENT, ALL REQUIRED

DISCONNECTING MEANS SHALL BE FURNISHED AND INSTALLED AS A PART OF THE ELECTRICAL

WORK. COORDINATE LOCATIONS OF DISCONNECTING AND CONTROLLING MEANS WITH

EQUIPMENT TO MAINTAIN CODE AND INSTALLATION REQUIREMENTS. DEDICATED WORKING

SPACE FOR MOTOR CONTROLLERS AND SAFETY SWITCHES SHALL BE PER NEC 110.26

REQUIREMENTS.

10. ALL RACEWAY AND WIRING SHALL BE CONCEALED IN FINISHED SPACES, AND MAY BE INSTALLED

EXPOSED IN UNFINISHED SPACES SUCH AS MECHANICAL AND ELECTRICAL ROOMS. ALL

RACEWAY AND WIRING, WHETHER CONCEALED OR EXPOSED, SHALL BE RUN EITHER

PERPENDICULAR OR PARALLEL TO THE BUILDING'S STRUCTURAL COMPONENTS.

11. PROVIDE PULL AND JUNCTION BOXES AS REQUIRED TO MEET CODE AND INSTALLATION

REQUIREMENTS. PULL AND JUNCTION BOXES SHALL BE CONCEALED IN FINISHED SPACES AND

LOCATIONS SHALL BE COORDINATED WITH THE WORK OF ALL OTHER TRADES SO AS TO AVOID

CONFLICTS.

12. ALL CONDUCTORS SHALL BE IDENTIFIED AT EACH JUNCTION BOX, OUTLET BOX, CABINET, PULL

BOX, ETC., WITH VINYL SELF-ADHESIVE TAGS INDICATING PANEL AND CIRCUIT NUMBER,

CONTROL WIRE IDENTIFICATION NUMBER, OR OTHER APPROPRIATE INFORMATION. ALL PULL

AND JUNCTION BOXES SHALL BE LABELED AS TO FUNCTION.

13. ALL EQUIPMENT SHALL BE SECURELY FASTENED BY MEANS OF ANCHORS, RODS, HANGERS,

SUPPORTS, GUIDES, SWAY BRACES, ETC., TO MAINTAIN ALIGNMENT AND PREVENT EQUIPMENT

MOVEMENT.

14. ALL PENETRATIONS OF FIRE OR SMOKE RATED CONSTRUCTION SHALL BE SEALED WITH

FIRESTOPPING MATERIALS APPROVED AND LISTED FOR THE RATING OF THE CONSTRUCTION

TO BE PENETRATED. PROVIDE DOCUMENTATION ON ALL SUCH PENETRATION SEALING

SYSTEMS FOR VERIFICATION OF PROPER INSTALLATION.

15. ALL PENETRATIONS OF ROOFS, EXTERIOR WALLS, FOUNDATIONS, OR OTHER WATER OR

MOISTURE PROOF CONSTRUCTION SHALL BE SEALED WITH APPROPRIATE SEALING FITTINGS

OR SEALED CONSTRUCTION TO PREVENT THE INTRODUCTION OF MOISTURE INTO THE

BUILDING.

16. WHERE EMPTY RACEWAYS ARE INSTALLED, THEY SHALL BE LABELED AT BOTH ENDS AND

FITTED WITH NYLON PULLSTRINGS FOR FUTURE USE.

17. TO PREVENT PERSONNEL INJURY AND POTENTIAL SYSTEM FAILURE, ELECTRICAL WORK SHALL

BE PERFORMED ON DE-ENERGIZED SYSTEMS ONLY. WHERE WORK ON EXISTING SYSTEMS WILL

REQUIRE INTERRUPTION OF ELECTRICAL SERVICE, THEN TEMPORARY PROVISIONS

ACCEPTABLE TO THE OWNER FOR TEMPORARY POWER SHALL BE UTILIZED UNTIL THE WORK IS

COMPLETE. PROVIDE ARC FLASH LABELS FOR ALL SWITCHBOARDS, PANELBOARDS, AND

MOTOR CONTROL CENTERS.

18. WHERE 20A, 120V LIGHTING AND POWER CIRCUIT LENGTHS EXCEED 100 FEET, PROVIDE #10

PHASE AND NEUTRAL CONDUCTORS WITH #10 GND IN MIN. 3/4" CONDUIT.

19. IF THE CONTRACTOR SUBSTITUTES EQUIPMENT WITH DIFFERENT CHARACTERISTICS THAN

WHAT IS SPECIFIED, INCLUDING ELECTRICAL CHARACTERISTICS, IT IS THE CONTRACTORS

RESPONSIBILITY TO COORDINATE THESE DIFFERENCES WITH OTHER TRADES.

20. INSTALL CEILING MOUNTED OCCUPANCY SENSORS AT LEAST 6" AWAY FROM AIR DIFFUSERS.

21. IN SPACES WITH WALL-MOUNTED TILE WORK, COORDINATE EXACT LOCATION OF ELECTRICAL

ROUGH-IN WITH PROPOSED TILE PATTERN TO MINIMIZE THE AMOUNT OF TILE CUTTING

REQUIRED.

22. RECEPTACLES INSTALLED IN BATHROOMS SHALL BE GROUND FAULT - CIRCUIT INTERRUPTER

TYPE.

23. DEVICE BOXES SHALL BE MOUNTED FLUSH IN WALLS UNLESS OTHERWISE NOTED OR

REQUIRED. FLUSH SHALL BE DEFINED AS EVEN WITH THE FACE OF THE WALL, OR RECESSED

NO MORE THAN 1/16". J-BOXES INSTALLED WITH PLASTER RINGS TO BE FLUSH WITH WALL.

EXAMPLE: WALLS WITH 5/8" THICK SHEET ROCK REQUIRES 3/4" PLASTER RING. PROVIDE

PLASTER RINGS AS REQUIRED FOR VARYING WALL THICKNESS COVERINGS. J-BOXES TO BE

SUPPORTED WITH STUD-TO-STUD BACK BOX BRACING.

24. WALL BOXES FOR SINGLE AND TWO-GANG SWITCHES, CONVENIENCE OUTLETS, SHALL BE 4"

SQUARE. TELECOMMUNICATION OR DATA WALL BOXES SHALL BE 4-11/16" SQUARE BY 2-1/8"

DEEP. WALLS WITH 5/8 THICK SHEET ROCK REQUIRE 3/4" PLASTER RING. PROVIDE SINGLE OR

DOUBLE GANG PLASTER RINGS OF CORRECT DEPTH FOR WALL CONSTRUCTION FOR VARYING

WALL THICKNESS COVERINGS. J-BOXES TO BE SUPPORTED WITH STUD-TO-STUD BACK BOX

BRACING. SECTIONAL OR MULTI-GANG BOXES WITH APPROPRIATE PLASTER RINGS SHALL BE

USED FOR MULTI-GANG APPLICATIONS.

ELECTRICAL DEMOLITION NOTES

1. ALL ELECTRICAL ITEMS INSTALLED IN WALLS, FLOORS, OR CEILINGS TO BE DEMOLISHED

SHALL BE REMOVED IN THEIR ENTIRETY UNLESS OTHERWISE NOTED OR REQUIRED BY

OTHER CONDITIONS IN THESE DOCUMENTS. SEE DRAWINGS OF ALL OTHER TRADES FOR

EXTENT OF DEMOLITION WORK. ELECTRICAL ITEMS SHALL INCLUDE POWER, LIGHTING, AND

SPECIAL SYSTEMS. REFER ALL QUESTIONS OF APPLICABILITY TO THE A/E PRIOR TO BID FOR

CLARIFICATION; OTHERWISE, FIELD DECISIONS BY THE A/E SHALL BE BINDING.

2. IT IS NOTED THAT THESE DRAWINGS DEPICT THE GENERAL INTENT OF THE SCOPE OF THE

DEMOLITION WORK AND THAT NOT ALL ITEMS OF ELECTRICAL DEMOLITION ARE

NECESSARILY SHOWN. THE CONTRACTOR SHALL BE REQUIRED TO FIELD VERIFY AND FIELD

DETERMINE THE SCOPE OF THE DEMOLITION WORK PRIOR TO BID. REFER ALL QUESTIONS

TO THE A/E PRIOR TO BID FOR CLARIFICATION.

3. PHASING OF ELECTRICAL DEMOLITION SHALL FOLLOW THAT OF THE GENERAL CONTRACTOR.

COORDINATE REMOVAL OF ELECTRICAL WORK WITH OTHER CONSTRUCTION ACTIVITIES AND

THE REQUIREMENTS OF THE OWNER.

4. THE OWNER SHALL HAVE SALVAGE RIGHTS TO ANY ITEMS THAT ARE TO BE DEMOLISHED.

ITEMS SUCH AS SPEAKERS AND CAMERAS AND OTHER ITEMS THAT THE OWNER WISHES TO

SALVAGE SHALL BE CAREFULLY REMOVED AND STORED IN A LOCATION AS DIRECTED BY THE

OWNER. ALL OTHER ITEMS OF DEMOLITION SHALL BECOME THE PROPERTY OF THE

CONTRACTOR AND SHALL BE REMOVED FROM THE SITE.

5. WHERE DEMOLITION WORK WILL INTERRUPT CIRCUIT CONTINUITY TO OTHER AREAS OF THE

FACILITY THAT ARE TO REMAIN IN OPERATION, THEN RACEWAY AND WIRING SHALL BE

INSTALLED TO MAINTAIN THOSE AREAS IN COMPLETE OPERATION. PROVIDE TEMPORARY

CONNECTIONS AS REQUIRED. COORDINATE ANY INTERRUPTIONS WITH THE OWNER AT

LEAST TWO WEEKS PRIOR AND ACCOMMODATE THE OWNER'S NEEDS AS REQUIRED.

6. ELECTRICAL CIRCUITS THAT ARE TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY.

CONDUCTORS SHALL BE REMOVED FROM THE ITEM TO BE DEMOLISHED TO THE SOURCE

OVERCURRENT DEVICE. RACEWAYS WHICH ARE INSTALLED IN OR BELOW FLOORS OR

WITHIN WALLS MAY BE ABANDONED, BUT ALL OVERHEAD OR EXPOSED RACEWAYS SHALL BE

REMOVED. EXPOSED RACEWAYS TO BE ABANDONED SHALL BE REMOVED AND SHALL BE

CUT OR CHISELED AT LEAST 2"" INTO THE WALL OR FLOOR AND THE OPENING GROUTED

SMOOTH.

7. WHERE EXISTING DEVICE OR JUNCTION BOXES MUST REMAIN IN EXISTING WALLS OR

CEILINGS (SUCH AS FOR CIRCUITS THAT MUST BE MAINTAINED TO OTHER AREAS), THEN

THEY SHALL BE FITTED WITH BLANK COVERPLATES.

8. WHERE DISTRIBUTION OR BRANCH CIRCUIT EQUIPMENT (PANELBOARDS, SWITCHBOARDS,

ETC.) IS TO BE REMOVED, THEN ALL CIRCUITS WHICH FEED ITEMS TO REMAIN SHALL BE

RECONNECTED TO NEW DISTRIBUTION OR BRANCH CIRCUIT EQUIPMENT. REFER ALL

QUESTIONS TO THE A/E FOR CLARIFICATION.

9. THE EXISTING FIRE ALARM SYSTEM SHALL REMAIN IN OPERATION THROUGHOUT

CONSTRUCTION. AUTOMATIC SMOKE DETECTORS IN THE AREA OF CONSTRUCTION SHALL

BE DISCONNECTED AND TEMPORARILY REPLACED WITH HEAT DETECTORS WHEN THE SPACE

IS STAFFED BY THE CONTRACTOR IN ACCORDANCE WITH THE APPROVED FIRE SAFETY

PROCEDURES OF THE OWNER AND THE LOCAL FIRE MARSHALL, BUT SHALL BE REACTIVATED

WHENEVER THE SPACE IS NOT OCCUPIED BY THE CONTRACTOR. AUTOMATIC SMOKE

DETECTORS SHALL BE PROTECTED FROM DUST AND DIRT ACCUMULATION BY REMOVING

THE DEVICE FROM ITS BASE DURING THOSE TIMES WHEN THE SYSTEM IS ALLOWED TO BE

OUT OF OPERATION.

10. IF HAZARDOUS MATERIALS (I.E. ASBESTOS, PCB's, ETC.) ARE ENCOUNTERED AT ANY TIME

DURING CONSTRUCTION IN THE WORK AREA, STOP WORK IMMEDIATELY AND CONTACT THE

A/E OR THE OWNER.

11. REMOVE ALL DEVICES SHOWN ON DEMOLITION PLAN UNLESS OTHERWISE NOTED.

12. REMOVE CABLING BACK TO SOURCE FOR ALL TEL/DATA OUTLETS BEING REMOVED.

FIRE ALARM GENERAL NOTES

1. ALL ELECTRICAL WORK SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE APPLICABLE

EDITIONS OF NFPA 70, NFPA 72, IBC, AND ANY OTHER LOCAL, STATE, OR FEDERAL CODES,

ORDINANCES, OR AUTHORITATIVE INTERPRETATIONS THAT MAY APPLY. SEE A COMPLETE

CODE REFERENCE ON SHEET F000. A CERTIFICATE OF FINAL ELECTRICAL INSPECTION

SHALL BE OBTAINED BY THE CONTRACTOR AT THE COMPLETION OF THE WORK AND

PRESENTED TO BOTH THE OWNER AND THE A/E.

2. THE CONTRACTOR SHALL FURNISH AND INSTALL COMPLETE AND SATISFACTORILY

OPERATING SYSTEMS AS INDICATED ON THE CONTRACT DOCUMENTS AND AS EVIDENTLY

INTENDED. IT IS NOTED THAT THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL

ARRANGEMENTS OF SYSTEMS AND WORK. INTERCONNECTIONS HAVE BEEN SHOWN, AND

THE CONTRACTOR SHALL FURNISH AND INSTALL CONDUIT AND WIRING AS REQUIRED TO

ACCOMPLISH THE FUNCTIONS INDICATED. ADDITIONALLY, FIRE ALARM SYSTEM HAVE BEEN

SHOWN AND THE CONTRACTOR SHALL FURNISH AND INSTALL THE REQUIRED QUANTITIES

AND TYPES OF CABLES, CONDUCTORS, RACEWAYS, REMOTE POWER SUPPLIES AND

CONNECTIONS, SHIELDING REQUIREMENTS, ETC., AS REQUIRED BY THE SYSTEM

MANUFACTURER, THE SPECIFICATIONS, AND ANY APPLICABLE CODES. ALL WIRING SHOWN

ON RISER DIAGRAMS SHALL ALSO BE FURNISHED AND INSTALLED REGARDLESS OF

WHETHER THESE ITEMS ARE SHOWN ON THE FLOOR PLANS.

3. THE CONTRACTOR SHALL COORDINATE THE ELECTRICAL WORK WITH THE WORK OF ALL

OTHER TRADES AND EXISTING CONDITIONS SO AS TO AVOID CONFLICTS. RESOLVE ALL

CONFLICTS THROUGH THE A/E PRIOR TO ROUGH-IN. FAILURE TO PROVIDE SUCH

COORDINATION PRIOR TO WORK BEING INSTALLED SHALL NOT BE CAUSE FOR ADDITIONAL

COMPENSATION TO THE CONTRACTOR, AND MAY RESULT IN REJECTION OF THE WORK.

4. ADDITIONAL DEVICES MAY BE REQUIRED. DO NOT USE THESE DRAWINGS FOR DEVICE

COUNTS.

5. ALL MATERIALS SHALL BE NEW, SHALL BE SUITABLE FOR THE APPLICATION INTENDED, AND

SHALL BEAR LABELS OR MARKINGS INDICATING THIRD PARTY TESTING LABORATORY

LISTINGS ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION.

6. VERIFY LOCATIONS OF WIRING DEVICES IN FINISHED…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .