This is an asbestos survey document prepared by MC Consulting Inc. for Building 1. The document details the location and assessment of asbestos-containing materials (ACM) throughout the first floor of the building, organized by room and section. The survey identifies the specific areas where ACM is present, quantifies the percentage composition, categorizes the material type, and notes the quantity of samples collected. The assessment includes evaluations of whether materials are friable or non-friable, their current condition, and the potential for disturbance. Additional columns track reevaluation dates from 2010, relevant comments regarding the condition and location of materials, and ranking classifications to prioritize areas of concern.
This asbestos survey serves as a baseline assessment supporting the associated federal contract opportunity for Phase 2 repairs to Building 1's steam and condensate risers at a Department of Veterans Affairs Veterans Integrated Service Network 12 facility (Solicitation Number 36C25226B0012). The survey data is essential for contractors bidding on renovation or repair work, as it identifies locations where asbestos abatement or containment procedures must be implemented in compliance with federal and environmental regulations before mechanical work can proceed.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MC Consulting Inc. BLDG 1 SEC A 1ST FL
LOCATION ACM % TYPE QTY SAMPLE MATERIAL DESCRIPTION REEVALUATION 2010 COMMENTS
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
AREA 1ST FLOOR
ROOM Al
VFT <1 CHR 400 SF 98015-X 1'X1' TAN W/BRN & WHT STRK N GOOD LOW NO CHANGE
7 MSTC 30 CHR 400 SF 98016-X MSTC FOR 98015 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 928 SF 98051-X PLAS Y GOOD MOD NO CHANGE
ACT 0 N/A 400 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
ROOM A101
VFT <1 CHR 224 SF 98015-X 1'X1' TAN W/BR & WHT STRK N GOOD LOW NO CHANGE
7 MSTC 30 CHR 224 SF 98016-X MSTC FOR 98015 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 480 SF 98051-X PLAS Y GOOD MOD NO CHANGE
ACT 0 N/A 224 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y GOOD LOW NOT LISTED ON ORIGINAL
ACT 0 N/A 400 SF 98102-X 2'X4' WHT WORM Y GOOD LOW
ROOM A102
VFT <1 CHR 750 SF 98015-X 1'X1' TAN W/BRN & WHT STRK N GOOD LOW NO CHANGE
7 MSTC 30 CHR 750 SF 98016-X MSTC FOR 98015 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 1430 SF 98051-X PLAS Y GOOD MOD NO CHANGE
BSBRD 0 N/A 65 SF 98056-X 411 BRN BSBRD N GOOD LOW NO CHANGE
MSTC 0 N/A 27 SF 98057-X MSTC FOR 98056 N GOOD LOW NO CHANGE
ACT 0 N/A 750 SF 98103-X 1'X1' WHT WRM TILES Y GOOD LOW NO CHANGE
MSTC 0 N/A 750 SF 98105-X MSTC FOR 98103 N GOOD LOW NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
4 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
ROOM A103
VFT <1 CHR 235 SF 98015-X 1'X1' TAN W/BRN & WHT STRK N GOOD LOW NO CHANGE
7 MSTC 30 CHR 235 SF 98016-X MSTC FOR 98015 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 480 SF 98051-X PLAS Y GOOD MOD NO CHANGE
ACT 0 N/A 225 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW
LOCALIZED DAMAGE IN HALL OUTSIDE
OF RM 101
7 PIPE-STM 70 CHR 98137-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
4 PIPE-STM 70 CHR 11 LF 98137-X STEAM RISER Y GOOD LOW NO CHANGE
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
ROOM A104
VFT N/A N/A N/A N/A VFT N/A N/A N/A
12X12 GREY WITH CREAM FT NOT
LISTED ON ORIGINAL
MSTC N/A N/A N/A N/A MSTC N/A N/A N/A NOT LISTED ON ORIGINAL
BSBRD N/A N/A N/A N/A BSBRD N/A N/A N/A NOT LISTED ON ORIGINAL
NSINS N/A N/A N/A N/A NSINS N/A N/A N/A NO CHANGE
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
PLAS-W 0 N/A 560 SF 98051-X PLAS Y GOOD MOD NO CHANGE
PLAS-A 0 N/A 300 SF 98101-X PLAS Y GOOD MOD NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
VIB 0 N/A 98201-X VIB DAMP Y GOOD LOW NO CHANGE
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
ROOM A105
VFT <1 CHR 70 SF 98015-X 1'X1' TAN W/BRN & WHT STRK N GOOD LOW CARPET OVER FLOOR TILE
7 MSTC 30 CHR 70 SF 98016-X MSTC FOR 98015 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 432 SF 98051-X PLAS Y GOOD MOD NO CHANGE
ACT 0 N/A 180 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
4 PIPE-STM 70 CHR 11 LF 98137-X STEAM RISER Y GOOD LOW NO CHANGE
PIPE-
COND 70 CHR 98212-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
ROOM A106 NOT ACCESSIBLE
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NOT ACCESSIBLE
NSINS N/A N/A N/A N/A NSINS N/A N/A N/A NOT ACCESSIBLE
NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NOT ACCESSIBLE
PLAS-W 0 N/A 480 SF 98051-X PLAS Y GOOD MOD NOT ACCESSIBLE
PLAS-A 0 N/A 384 SF 98101-X PLAS Y GOOD MOD NOT ACCESSIBLE
7 PIPE-STM 70 CHR 98137-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
PIPE F-
STM 0 N/A N/A 98142-X STM FITG ON FIB PIPE Y GOOD LOW NOT ACCESSIBLE
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
7 VFT 12 CHR 384 SF 98009-
9"X9" LT BRN W/BLU & BRN
STRK N GOOD LOW NOT ACCESSIBLE
7 MSTC 10 CHR 384 SF 98010- MSTC FOR 98009 N GOOD LOW NOT ACCESSIBLE
PIPE F-
CON 0 N/A 10 LF 98158- COND FITG Y GOOD LOW NOT ACCESSIBLE
VIB 0 N/A N/A 98201- VIB DAMP N GOOD LOW NOT ACCESSIBLE
OTHR 0 N/A N/A 98202- GASKET (SEAL) N GOOD LOW NOT ACCESSIBLE
ROOM A106A
NSINS N/A N/A N/A N/A NSINS N/A N/A N/A NO CHANGE
7 VFT 25 CHR 24 SF 98002-X 9"X9" BLK W/WHTSTRK N GOOD LOW NO CHANGE
7 VFT 15 CHR 24 SF 98003-X 9"X9" GRY W/BLKSTRK N GOOD LOW NO CHANGE
7 MSTC 8 CHR 48 SF 98005-X MSTC FOR 98002,98003 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 308 SF 98051-X PLAS Y GOOD MOD NO CHANGE
PLAS-A 0 N/A 49 SF 98101-X PLAS Y GOOD MOD NO CHANGE
ROOM A107 NO CHANGE
NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
PLAS-W 0 136 SF 98051-X PLAS Y GOOD MOD NO CHANGE
PLAS-A 0 N/A 70 SF 98101-X PLAS Y GOOD MOD NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
ROOM A109 NOT ACCESSIBLE
VFT <1 CHR 242 SF 98015-X 1'X1' TAN W/BRN & WHT STRK N GOOD LOW NOT ACCESSIBLE
7 MSTC 30 CHR 242 SF 98016-X MSTC FOR 98015 N GOOD LOW NOT ACCESSIBLE
PLAS-W 0 N/A 528 SF 98051-X PLAS Y GOOD MOD NOT ACCESSIBLE
ACT 0 N/A 242 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NOT ACCESSIBLE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
ROOM A110
VFT <1 CHR 475 SF 98015-X 1'X1' TAN W/BRN & WHT STRK N GOOD LOW NO CHANGE
7 MSTC 30 CHR 475 SF 98016-X MSTC FOR 98015 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 512 SF 98051-X PLAS Y GOOD MOD NO CHANGE
ACT 0 N/A 240 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
PIPE-STM N/A N/A N/A N/A STEAM RISER N/A N/A N/A ABATED
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
ROOM A113
VFT <1 CHR 252 SF 98015-X 1'X1' TAN W/BRN & WHT STRK N GOOD LOW NO CHANGE
7 MSTC 30 CHR 252 SF 98016-X MSTC FOR 98015 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 512 SF 98051-X PLAS Y GOOD MOD NO CHANGE
ACT 0 N/A 252 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
4 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
ROOM A114
7 VFT 25 CHR 24 SF 98002-X 9"X9" BLK W/WHTSTRK N GOOD LOW NO CHANGE
7 VFT 15 CHR 24 SF 98003-X 9"X9" GRY W/BLKSTRK N GOOD LOW NO CHANGE
7 VFT 7 CHR N/A 98004-X 2'X.5 BLK BORDER TILE N GOOD LOW NO CHANGE
7 MSTC 8 CHR 54 SF 98005-X MSTC FOR 98002,98003,98004 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 338 SF 98051-X PLAS Y GOOD MOD NO CHANGE
PLAS-A 0 N/A 42 SF 98101-X PLAS Y GOOD MOD NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
ROOM A116
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A TERAZZO FLOOR BROWN
PLAS-W 0 N/A 550 SF 98051-X PLAS Y GOOD MOD NO CHANGE
PLAS-A 0 N/A 90 SF 98101-X PLAS Y GOOD MOD NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
ROOM A117
VFT <1 CHR 168 SF 98015-X 1'X1' TAN W/BRN & WHT STRK N GOOD LOW NO CHANGE
7 MSTC 30 CHR 168 SF 98016-X MSTC FOR 98015 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 384 SF 98051-X PLAS Y GOOD MOD NO CHANGE
BSBRD 0 N/A 24 SF 98056-X 4" BRN BSBRD N GOOD LOW NO CHANGE
MSTC 0 N/A 24 SF 98057-X MSTC FOR 98056 N GOOD LOW NO CHANGE
ACT 0 N/A 144 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
ROOM A118
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
VFT <1 CHR 760 SF 98015-X 1'X1' TAN W/BRN & WHT STRK N GOOD LOW NO CHANGE
7 MSTC 30 CHR 760 SF 98016-X MSTC FOR 98015 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 896 SF 98051-X PUS Y GOOD MOD NO CHANGE
ACT 0 N/A 768 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
4 PIPE-STM 70 CHR 11 LF 98137-X STEAM RISER Y GOOD LOW NO CHANGE
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
ROOM A119
VFT <1 CHR 420 SF 98015-X 1'X1' TAN W/BRN & WHT STRK N GOOD LOW NO CHANGE
7 MSTC 30 CHR 420 SF 98016-X MSTC FOR 98015 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 656 SF 98051-X PLAS Y GOOD MOD NO CHANGE
ACT 0 N/A 420 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
ROOM A122
VFT <1 CHR 168 SF 98015-X 1'X1' TAN W/BRN & WHT STRK N GOOD LOW NO CHANGE
7 MSTC 30 CHR 168 SF 98016-X MSTC FOR 98015 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 416 SF 98051-X PLAS Y GOOD MOD NO CHANGE
BSBRD 0 N/A 48 SF 98056-X 4" BRN BSBRD N GOOD LOW NO CHANGE
MSTC 0 N/A 48 SF 98057-X MSTC FOR 98056 N GOOD LOW NO CHANGE
ACT 0 N/A 168 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
ROOM A122A
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
WALL-BRD 0 N/A 192 SF 98055-X WALL BRD Y GOOD MOD NO CHANGE
PLAS-A 0 N/A 35 SF 98101-X PLAS N GOOD MOD NO CHANGE
ROOM A122B
VFT 0 N/A 40 SF 98001-X 1'X1' TAN W/TANMOT N GOOD LOW NO CHANGE
MSTC 0 N/A 40 SF 98001-X MSTC FOR 98001 LAB RESULT N GOOD LOW NO CHANGE
WALL-BRD 0 N/A 192 SF 98055-X WALL BRD NO CHANGE
ROOM A122B 12 SF 98056-X 4" BRN BSBRD
BSBRD 0 N/A N/A N/A BSBRD N GOOD LOW NO CHANGE
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
MSTC 0 N/A 11 SF 98057-X MSTC FOR 98056 N GOOD LOW NO CHANGE
ACT 0 N/A 35 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
ROOM A123
VFT <1 CHR 140 SF 98006-X 1'X1' TAN W/LG BRN STRKS N GOOD LOW NO CHANGE
7 MSTC 5 CHR 140 SF 98007-X MSTC FOR 98006 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 350 SF 98051-X PLAS Y GOOD MOD NO CHANGE
ACT 0 N/A 120 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
ROOM A124
VFT <1 CHR 288 SF 98006-X 1'X1' TAN W/LG BRN STRKS N GOOD LOW NO CHANGE
7 MSTC 5 CHR 288 SF 98007-X MSTC FOR 98006 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 544 SF 98051-X PLAS Y GOOD MOD NO CHANGE
PLAS-A 0 N/A 288 SF 98101-X PLAS Y GOOD MOD NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
4 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
7 DOOR 80 CHR 64 SF 98480-X ELEVATOR DOOR INS Y GOOD LOW NO CHANGE
ROOM A125
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
PLAS-W 0 N/A 320 SF 98051-X PLAS Y GOOD MOD NO CHANGE
ACT 0 N/A 96 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
ROOM A128
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A
12X12 FLOOR TILE AND MASTIC BELOW
CARPET
PLAS-W 0 N/A 560 SF 98051-X PLAS Y GOOD MOD NO CHANGE
ACT 0 N/A 286 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Presume behind walls & above ceilings
ROOM A129A
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
PLAS-W 0 N/A 736 SF 98051-X PLAS Y GOOD MOD NO CHANGE
ACT 0 N/A 448 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
4 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Presume behind walls & above ceilings
ROOM A132
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
ROOM A132
VFT <1 CHR 440 SF 98006-X 1'X1' TAN W/LG BRN STRKS N GOOD LOW NO CHANGE
7 MSTC 5 CHR 440 SF 98007-X MSTC FOR 98006 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 720 SF 98051-X PLAS Y GOOD MOD NO CHANGE
ACT 0 N/A 506 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
ROOM A133
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
PLAS-W 0 N/A 448 SF 98051-X PLAS Y GOOD MOD NO CHANGE
ACT 0 N/A 196 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
4 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW NO CHANGE
ROOM A133A
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
PLAS-W 0 N/A 640 SF 98051-X PLAS Y GOOD MOD NO CHANGE
ACT 0 N/A 350 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
4 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
ROOM A134
NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
NSINS N/A N/A N/A N/A NSINS N/A N/A N/A NO CHANGE
PLAS-W 0 N/A 736 SF 98051-X PLAS Y GOOD MOD NO CHANGE
PLAS-A 0 N/A 168 SF 98101-X PLAS Y GOOD MOD NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
OTHR 0 N/A N/A 98202-X GASKET (SEAL) N GOOD LOW NO CHANGE
ROOM A136
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
PLAS-W 0 N/A 384 SF 98051-X PLAS Y GOOD MOD NO CHANGE
PLAS-A 0 N/A 64 SF 98101-X PLAS Y GOOD MOD NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
ROOM A138
NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
PLAS-W 0 N/A 416 SF 98051-X PLAS Y GOOD MOD NO CHANGE
ROOM A148
7 VFT 25 CHR 96 SF 98002- 9"X9" BLK W/WHTSTRK N GOOD LOW NO CHANGE
7 VFT 15 CHR 96 SF 98003- 9"X9" GRY W/BLKSTRK N GOOD LOW NO CHANGE
7 VFT 7 CHR 10 SF 98004- 2'X.5 BLK BORDER TILE N GOOD LOW NO CHANGE
7 MSTC 8 CHR 200 SF 98005- MSTC FOR 98002,98003,98004 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 768 SF 98051- PLAS Y GOOD MOD NO CHANGE
OTHR 0 N/A 768 SF 98054- RED BRICK NO CHANGE
PLAS-A 0 N/A 190 SF 98101- PLAS-A Y GOOD MOD NO CHANGE
PIPE F-
DCW 0 N/A N/A 98151- CW Y GOOD LOW NO CHANGE
PIPE-STM 0 N/A 20 LF 98152- STEAM/DEAD LINE Y GOOD LOW NO CHANGE
1 PIPE-DHW 70 CHR 30 LF 98153- HW Y GOOD LOW NO CHANGE
PIPE-STM 0 30 LF 98154- STEAM/DEAD LINE Y GOOD LOW NO CHANGE
PIPE-
COND 50 CHR 30 LF 98155- COND Y GOOD LOW NO CHANGE
ROOM AlA
VFT <1 CHR 144 SF 98006-X 1'X1' TAN W/LG BRN STRKS N GOOD LOW NO CHANGE
7 MSTC 5 CHR 144 SF 98007-X MSTC FOR 98006 N GOOD LOW NO CHANGE
VFT <1 CHR 192 SF 98015-X 1'X1' TAN W/BRN & WHT STRK N GOOD LOW NO CHANGE
7 MSTC 30 CHR 192 SF 98016-X MSTC FOR 98015 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 800 SF 98051-X PLAS Y GOOD MOD NO CHANGE
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
ACT 0 N/A 336 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
ROOM A18 NO CHANGE
VFT <1 CHR 1040 SF 98006-X 1'X1' TAN W/LG BRN STRKS N GOOD LOW NO CHANGE
7 MSTC 5 CHR 1040 SF 98007-X MSTC FOR 98006 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 2210 SF 98051-X PLAS Y GOOD MOD NO CHANGE
ACT 0 N/A 1040 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
VFT <1 CHR 176 SF 98006- 1'X1' TAN W/LG BRN STRKS N GOOD LOW NO CHANGE
7 MSTC 5 CHR 176 SF 98007- MSTC FOR 98006 N GOOD LOW NO CHANGE
BSBRD 0 N/A 46 SF 98056- 4" BRN BSBRD N GOOD LOW NO CHANGE
MSTC 0 N/A 48 SF 98057- MSTC FOR 98056 N GOOD LOW NO CHANGE
ROOM A138
PLAS-A 0 N/A 168 SF 98101-X PLAS Y GOOD MOD NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
ROOM A140
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE
PLAS-W 0 N/A 416 SF 98051-X PLAS Y GOOD MOD NO CHANGE
PLAS-A 0 N/A 168 SF 98101-X PLAS Y GOOD MOD NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
ROOM A141
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
ROOM A142
NSFM N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
PLAS-W 0 N/A 336 SF 98051-X PLAS Y GOOD MOD NO CHANGE
ACT 0 N/A 110 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
BSBRD 0 N/A 30 SF .98052- 4" TAN BSBRD N GOOD LOW NO CHANGE
MSTC 0 N/A 30 SF 98053- MSTC FOR 98052 N GOOD LOW NO CHANGE
WALL-BRD 0 N/A 80 SF 98055- WALL BRD Y GOOD MOD NO CHANGE
OTHR 0 N/A 10 SF 98343- WALL BRD TAPE Y GOOD LOW NO CHANGE
ROOM A142A
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
MSTC 0 N/A 1496 SF 98001-X MSTC FOR 98001 LAB RESULT N GOOD LOW NO CHANGE
PLAS-W 0 N/A 1250 SF 98051-X PLAS Y GOOD MOD NO CHANGE
BSBRD N/A 20 SF 98052-X 4" TAN BSBRD N GOOD LOW NO CHANGE
MSTC N/A 20 SF 98053-X MSTC FOR 98052 N GOOD LOW NO CHANGE
4 PIPE-STM 70 CHR 33 LF 98137-X STEAM RISER NO CHANGE
VFT 0 N/A 1496 SF 98001- 1'X1' TAN W/TANMOT N GOOD LOW NO CHANGE
ACT N/A 1500 SF 98102- 2'X4' WHT WORM Y GOOD LOW NO CHANGE
PIPE F-
STM 60 CHR N/A 98156- STM FITG Y GOOD LOW NO CHANGE
PIPE F-
CON 40 CHR N/A 98157- COND FITG Y GOOD LOW NO CHANGE
ROOM A142B
VFT <1 CHR 156 SF 98006-X 1'X1' TAN W/LG BRN STRKS N GOOD LOW NO CHANGE
7 MSTC 5 CHR 156 SF 98007-X MSTC FOR 98006 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 368 SF 98051-X PLAS Y GOOD MOD NO CHANGE
ACT 0 N/A 130 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
ROOM A143 NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings
Abated Date Work Order Project No. Report Point of Contact Notes
MC Consulting Inc. BLDG 1 SEC A 2ND FL
LOCATION ACM % TYPE QTY SAMPLE MATERIAL DESCRIPTION COMMENTS
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
AREA 2ND FLOOR
ROOM A2
MSTC 0 N/A 640 SF 98011-X MSTC FOR 98008 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 1410 SF 98051-X PLAS N GOOD MOD NO CHANGE
ACT 0 N/A 640 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
ROOM A201
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE
7 VFT 1 CHR 224 SF 98014-X 1'X1' WHT W/BLU STRKS N GOOD LOW CARPET OVER FLOORING
7 MSTC 30 CHR 224 SF 98016-X MSTC FOR 98014 N GOOD LOW CARPET OVER FLOORING
ACT 0 N/A 224 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A201A
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE
VFT 1 CHR 240 SF 98014-X 1'X1' WHT W/BLU STRKS N GOOD LOW CARPET OVER FLOORING
MSTC 30 CHR 240 SF 98016-X MSTC FOR 98014 N GOOD LOW CARPET OVER FLOORING
PLAS-W 0 N/A 500 SF 98051-X PLAS N GOOD MOD NO CHANGE
ACT 0 N/A 195 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
ACT 0 N/A 195 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A202
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A CARPET OVER FLOORING
PLAS-W 0 N/A 480 SF 98051-X PLAS N GOOD MOD NO CHANGE
WALL-BRD 0 N/A 480 SF 98055-X WALL BRD N GOOD MOD NO CHANGE
ACT 0 N/A 224 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A202A
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
PLAS-W 0 N/A 480 SF 98051-X PLAS N GOOD MOD NO CHANGE
REEVALUATION 2010
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
REEVALUATION 2010
WALL-BRD 0 N/A 480 SF 98055-X WALL BRD N GOOD MOD NO CHANGE
ACT 0 N/A 224 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A202B
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
PLAS-W 0 N/A 450 SF 98051-X PLAS N GOOD MOD NO CHANGE
WALL-BRD 0 N/A 450 SF 98055-X WALL BRD N GOOD MOD NO CHANGE
ACT 0 N/A 195 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A204
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE
PLAS-W 0 N/A 640 SF 98051-X PLAS N GOOD MOD NO CHANGE
BSBRD 0 N/A N/A 98058-X 4" BLK BSBRD N GOOD LOW 6" BLK BSBRD
MSTC 0 N/A N/A 98059-X MSTC FOR 98058 N GOOD LOW NO CHANGE
PLAS-A 0 N/A 375 SF 98101-X PLAS N GOOD MOD NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A205
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A CARPET OVER FLOORING
PLAS-W 0 N/A 480 SF 98051-X PLAS N GOOD MOD NO CHANGE
ACT 0 N/A 224 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A206
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
REEVALUATION 2010
NSINS N/A N/A N/A N/A NSINS N/A N/A N/A NO CHANGE
NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
PLAS-W 0 N/A 670 SF 98051-X PLAS N GOOD MOD NO CHANGE
PLAS-A 0 N/A 416 SF 98101-X PLAS N GOOD MOD NO CHANGE
PIPE-DCW 0 N/A 11 LF 98128-X CW Y GOOD LOW NO CHANGE
PIPE-DHW 0 N/A 30 LF 98129-X HW Y GOOD LOW LOCALIZED DAMAGE
4 PIPE-DCW 15 CHR 30 LF 98132-X CW Y GOOD LOW LOCALIZED DAMAGE
1 DEBRIS 65 CHR 30 SF 98135-X PIPE DEBRIS Y NO CHANGE
4 PIPE-STM 70 CHR 11 LF 98137-X STEAM RISER Y GOOD LOW NO CHANGE
OTHR 0 N/A N/A 98202-X GASKET N GOOD LOW NO CHANGE
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
VFT 0 N/A 195 SF 98012- BRN FLOOR SHEET N GOOD LOW NO CHANGE
MSTC 0 N/A 195 SF 98013- MSTC FOR 98012 N GOOD LOW NO CHANGE
VIB 0 N/A N/A 98201- VIB DAM N GOOD LOW NO CHANGE
ROOM A207
7 VFT 1 CHR 92 SF 98014-X 1'X1' WHT W/BLU STRKS N GOOD LOW NO CHANGE
7 MSTC 30 CHR 92 SF 98016-X MSTC FOR 98014 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 320 SF 98051-X PLAS N GOOD MOD NO CHANGE
BSBRD 0 N/A N/A 98061-X 6" BRN BSBRD N GOOD LOW NO CHANGE
MSTC 0 N/A N/A 98062-X MSTC FOR 98061 N GOOD LOW NO CHANGE
PLAS-A 0 N/A 84 SF 98101-X PLAS N GOOD MOD NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X W-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A209 ROOM COMBINED WITH 211
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE
PLAS-W 0 N/A 400 SF 98051-X PLAS N GOOD MOD NO CHANGE
ACT 0 N/A 150 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
REEVALUATION 2010
ROOM A211
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE
PLAS-W 0 N/A 420 SF 98051-X PLAS N GOOD MOD NO CHANGE
ACT 0 N/A 168 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CUR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A212
PLAS-W 0 N/A 580 SF 98051-X PLAS N GOOD MOD NO CHANGE
ACT 0 N/A 320 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
VFT <1 CHR 320 SF 98015- 1'X1' TAN W/WHT & BRN STRKS N GOOD LOW NO CHANGE
7 MSTC 25 CHR 320 SF 98017- MSTC FOR 98015 N GOOD LOW NO CHANGE
ROOM A213
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
PLAS-W 0 N/A 420 SF 98051-X PLAS N GOOD MOD NO CHANGE
ACT 0 N/A 192 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A214
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
REEVALUATION 2010
TRANSITE
FUME
HOOD N/A N/A 60 SF N/A TRANSITE FUME HOOD N GOOD LOW Presume
BLACK
TABLETOP N/A N/A 100 SF N/A BLACK TABLETOP N GOOD LOW Presume
7 VFT 1 CHR 336 SF 98014-X 1'X1' WHT W/BLU STRKS N GOOD LOW NO CHANGE
7 MSTC 30 CHR 336 SF 98016-X MSTC FOR 98014 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 610 SF 98051-X PLAS N GOOD MOD NO CHANGE
ACT 0 N/A 336 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A216
VFT <1 CHR 400 SF 98022-X 1'X1' WHT W/GRY& BRN LG CHNK N GOOD LOW NO CHANGE
MSTC 0 N/A 400 SF 98023-X MSTC FOR 98022 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 660 SF 98051-X PLAS N GOOD MOD NO CHANGE
ACT 0 N/A 400 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A217
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A CARPET OVER FLOORING
PLAS-W 0 N/A 420 SF 98051-X PLAS N GOOD MOD NO CHANGE
BSBRD 0 N/A N/A 98061-X 6" BRN BSBRD N GOOD LOW 3" BLACK BSBRD
MSTC 0 N/A N/A 98062-X MSTC FOR 98061 N GOOD LOW NO CHANGE
ACT 0 N/A 168 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
REEVALUATION 2010
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A218
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A
PLAS-W 0 N/A 450 SF 98051-X PLAS N GOOD MOD NO CHANGE
ACT 0 N/A 192 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
PIPE-DHW 0 N/A 11 LF 98129-X HW Y GOOD LOW NO CHANGE
4 PIPE-DCW 15 CHR 11 LF 98132-X CW Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A218A
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
PLAS-W 0 N/A 224 SF 98051-X PUS N GOOD MOD NO CHANGE
PLAS-A 0 N/A 48 SF 98101-X PLAS N GOOD MOD NO CHANGE
ROOM A219
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A CARPET OVER LEVELER
PLAS-W 0 N/A 660 SF 98051-X PLAS N GOOD MOD NO CHANGE
BSBRD 0 N/A 22 SF 98061-X 6" BRN BSBRD N GOOD LOW 3" BLACK BSBRD
MSTC 0 N/A 22 SF 98062-X MSTC FOR 98061 N GOOD LOW NO CHANGE
ACT 0 N/A 420 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
ACT 0 N/A 420 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A220
VFT <1 N/A 288 SF 98006-X 1'X1' TAN W/LG BRN STRKS N GOOD LOW NO CHANGE
7 MSTC 5 CHR 288 SF 98007-X MSTC FOR 98006 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 544 SF 98051-X PLAS N GOOD MOD NO CHANGE
PLAS-A 0 N/A 288 SF 98101-X PLAS N GOOD MOD NO CHANGE
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
REEVALUATION 2010
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
4 PIPE-STM 70 CHR 11 LF 98137-X STEAM Y GOOD LOW NO CHANGE
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 DOOR 80 CHR 64 SF 98480-X ELEVATOR DOOR INS Y GOOD LOW NO CHANGE
ROOM 223
VFT N/A N/A 200 SF N/A BROWN N GOOD LOW Presumed
TERRAZZ
O BB N/A N/A 100 SF N/A 6" BROWN N GOOD LOW Presumed
ROOM A224
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
PLAS-W 0 N/A 624 SF 98051-X PLAS N GOOD MOD NO CHANGE
ACT 0 N/A 360 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
4 PIPE-STM 70 CHR 11 LF 98137-X STEAM Y GOOD LOW NO CHANGE
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 VFT 1 CHR 519 SF 98014- 1'X1' WHT W/BLU STRKS N GOOD LOW NO CHANGE
7 MSTC 30 CHR 519 SF 98016- MSTC FOR 98014 N GOOD LOW NO CHANGE
ROOM A225
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A CARPET OVER FLOOR TILE
PLAS-W 0 N/A 350 SF 98051-X PLAS N GOOD MOD NO CHANGE
BSBRD 0 N/A N/A 98061-X 6" BRN BSBRD N GOOD LOW NO CHANGE
MSTC 0 N/A N/A 98062-X MSTC FOR 98061 N GOOD LOW NO CHANGE
ACT 0 N/A 112 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM 227
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
REEVALUATION 2010
CARPET
OVER FT NOT LISTED ON ORIGINAL
ROOM A228
BLACK
TRANSITE
WORKBEN
CH N/A N/A 100 SF N/A BLACK TRANSITE WORKBENCH N GOOD LOW Presumed
VFT <1 CHR 432 SF 98015-X 1'X1' TAN W/WHT & BRN STRKS N GOOD LOW NO CHANGE
7 MSTC 25 CHR 432 SF 98017-X MSTC FOR 98015 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 670 SF 98051-X PLAS N GOOD MOD NO CHANGE
BSBRD 0 N/A 20 SF 98058-X 4" BLK BSBRD N GOOD LOW NO CHANGE
MSTC 0 N/A 20 SF 98059-X MSTC FOR 98058 N GOOD LOW NO CHANGE
ACT 0 N/A 432 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A229
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A CARPET
PLAS-W 0 N/A 350 SF 98051-X PLAS N GOOD MOD NO CHANGE
BSBRD 0 N/A N/A 98061-X 6" BRN BSBRD N GOOD LOW NO CHANGE
MSTC 0 N/A N/A 98062-X MSTC FOR 98061 N GOOD LOW NO CHANGE
ACT 0 N/A 120 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A230
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
NSINS N/A N/A N/A N/A NSINS N/A N/A N/A NO CHANGE
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
REEVALUATION 2010
PLAS-W 0 500 SF 98051-X PLAS N GOOD MOD NO CHANGE
PLAS-A 0 240 SF 98101-X PLAS N GOOD MOD NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
OTHR 0 N/A N/A 98202-X GASKET N GOOD LOW NO CHANGE
VIB 0 N/A N/A 98207-X VIB DAM N GOOD LOW NO CHANGE
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
OTHR 0 N/A 75 SF 98203- DUCT COVER N GOOD LOW NO CHANGE
ROOM A231
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A CARPET OVER LEVELER
ROOM A231
NSINS N/A N/A N/A N/A NSINS N/A N/A N/A NO CHANGE
PLAS-W 0 N/A 400 SF 98051-X PLAS N GOOD MOD NO CHANGE
BSBRD 0 N/A 15 SF 98061-X 6" BRN BSBRD N GOOD LOW 3" BLACK BSBRD
MSTC 0 N/A 15 SF 98062-X MSTC FOR 98061 N GOOD LOW NO CHANGE
ACT 0 N/A 154 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A232
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A BROWN VINYL FLOORING
PLAS-W 0 N/A 350 SF 98051-X PLAS N GOOD MOD NO CHANGE
PLAS-A 0 N/A 64 SF 98101-X PLAS N GOOD MOD NO CHANGE
ROOM A234
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE
PLAS-A 0 N/A 24 SF 98101-X PLAS N GOOD MOD NO CHANGE
ACT 0 N/A 160 SF 98103-X 1'X1' WHT WRM TILES . Y GOOD LOW 2X4 CT ON WALLS
MSTC 0 N/A 160 SF 98105-X MSTC FOR 98103 N GOOD LOW NO CHANGE
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
REEVALUATION 2010
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A235
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A
PLAS-W 0 N/A 700 SF 98051-X PLAS N GOOD MOD NO CHANGE
ACT 0 N/A 420 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
4 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
BSBRD 0 N/A 35 SF 98061- 6" BRN BSBRD N GOOD LOW NO CHANGE
MSTC 0 N/A 35 SF 98062- MSTC FOR 98061 N GOOD LOW NO CHANGE
ROOM A236
NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE
VFT 0 N/A 224 SF 98008-X 1'X1' WHT W/BRN CHNK N GOOD LOW NO CHANGE
MSTC 0 N/A 224 SF 98011-X MSTC FOR 98008 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 480 SF 98051-X PLAS N GOOD MOD NO CHANGE
ACT 0 N/A 224 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A238
6"
TERRAZZ
O BB N/A N/A 100 SF N/A 6" TERRAZZO BB N GOOD LOW Presumed
BLACK
TABLETOP N/A N/A 100 SF N/A BLACK TABLETOP N GOOD LOW Presumed
7 VFT 1 CHR 544 SF 98014-X 1'X1' WHT W/BLU STRKS N GOOD LOW NO CHANGE
7 MSTC 30 CHR 544 SF 98016-X MSTC FOR 98014 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 800 SF 98051-X PLAS N GOOD MOD NO CHANGE
ACT 0 N/A 544 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
REEVALUATION 2010
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
BSBRD 0 N/A 10 SF 98058- 4" BLK BSBRD N GOOD LOW NO CHANGE
MSTC 0 N/A 10 SF 98059- MSTC FOR 98058 N GOOD LOW NO CHANGE
ROOM A239
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A CARPET OVER FT
PLAS-W 0 N/A 350 SF 98051-X PLAS N GOOD MOD NO CHANGE
BSBRD 0 N/A 28 SF 98061-X 6" BRN BSBRD N GOOD LOW NO CHANGE
MSTC 0 N/A 28 SF 98062-X MSTC FOR 98061 N GOOD LOW NO CHANGE
ACT 0 N/A 112 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A240
6"
TERRAZZ
O BB N/A N/A 100 SF N/A 6" TERRAZZO BB N GOOD LOW Presumed
SINK
UNDERCO
ATING N/A N/A 50 SF N/A SINK UNDERCOATING N GOOD MOD Presumed
7 VFT 1 CHR 480 SF 98014-X 1'X1' WHT W/BLU STRKS N GOOD LOW NO CHANGE
7 MSTC 30 CHR 480 SF 98016-X MSTC FOR 98016 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 800 SF 98051-X PLAS N GOOD MOD NO CHANGE
ACT 0 N/A 480 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A241
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
REEVALUATION 2010
6"
TERRAZZ
O BB N/A N/A 100 SF N/A 6" TERRAZZO BB N GOOD LOW Presumed
VFT <1 CHR 200 SF 98015-X 1'X1' TAN W/WHT & BRN STRKS N GOOD LOW CARPET OVER FT
7 MSTC 25 CHR 200 SF 98017-X MSTC FOR 98015 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 480 SF 98051-X PLAS N GOOD MOD NO CHANGE
ACT 0 N/A 200 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
4 PIPE-STM 70 CHR 11 LF 98137-X STEAM Y GOOD LOW NO CHANGE
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A241A
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A242 COMBINED WITH RM 246
VFT <1 CHR 612 SF 98022-X 1'X1' WHT W/GRY& BRN LG CHNK N GOOD LOW NO CHANGE
MSTC 0 N/A 612 SF 98023-X MSTC FOR 98022 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 830 SF 98051-X PLAS N GOOD MOD NO CHANGE
BSBRD 0 N/A 50 SF 98061-X 6" BRN BSBRD N GOOD LOW NO CHANGE
MSTC 0 N/A 50 SF 98062-X MSTC FOR 98061 N GOOD LOW NO CHANGE
ACT 0 N/A 612 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A243
NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NEW GEY 12X12 FT
VFT 0 N/A 144 SF 98008-X 1'X1' WHT W/BRN CHNK N GOOD LOW NO CHANGE
MSTC 0 N/A 144 SF 98011-X MSTC FOR 98008 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 380 SF 98051-X PLAS N GOOD MOD NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE-
COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM 245
NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NOT LISTED ON ORIGINAL
ROOM A2A
6"
TERRAZZ
O BB N/A N/A 100 SF N/A 6" TERRAZZO BB N GOOD LOW Presumed
PLAS-W 0 N/A 580 SF 98051-X PLAS N GOOD MOD NO CHANGE
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
REEVALUATION 2010
ACT 0 N/A 192 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
VFT 0 N/A 192 SF 98008- 1'X1' WHT W/BRN CHNK N GOOD LOW NO CHANGE
MSTC 0 N/A 192 SF 98011- MSTC FOR 98008 N GOOD LOW NO CHANGE
ROOM A2B
PLAS-W 0 N/A 620 SF 98051-X PLAS N GOOD MOD NO CHANGE
ACT 0 N/A 960 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
4 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
VFT <1 CHR 126 SF 98018- 1'X1' OFF WHT W/GRY & TAN STRK N GOOD LOW NO CHANGE
7 MSTC 15 CHR 126 SF 98019- MSTC FOR 98018 N GOOD LOW NO CHANGE
ACT 0 224 SF 98104- 2'X4' GRY WRM W/PNHL Y GOOD LOW NO CHANGE
MC Consulting Inc. BLDG 1 SEC A 3RD FL
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
AREA 3RD FLOOR
ROOM A3
VFT 0 N/A 640 SF 98008-X 1'X1' WHT W/BRN CHNK N GOOD LOW NO CHANGE
MSTC 0 N/A 640 SF 98011-X MSTC FOR 98008 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 1410 SF 98051-X PLAS N GOOD MOD NO CHANGE
ACT 0 N/A 640 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE
4 PIPE-DHW 4 CHR 80 LF 98150-X HW Y GOOD LOW NO CHANGE
ROOM A300
OTHR N/A N/A 90 SF N/A LAB HOOD/NOT SAMPLED N GOOD LOW STAINLESS STEEL HOOD
BSBRD 0 N/A 20 SF 98058-X 4 BLK BSBRD N GOOD LOW NO CHANGE
VFT N/A N/A N/A N/A VFT N GOOD LOW NO CHANGE
7 MSTC 5 CHR 240 SF 98025-X MSTC FOR 98024 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 460 SF 98051-X PLAS N GOOD MOD NO CHANGE
ACT 0 N/A 210 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A302
NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE
VFT 0 N/A 160 SF 98008-X 1'X1' WHT W/BRN CHNK N GOOD LOW NO CHANGE
MSTC 0 N/A 640 SF 98011-X MSTC FOR 98008 N GOOD LOW NO CHANGE
VFT <1 CHR 160 SF 98022-X
1'X1' WHT W/GRY& BRN LG
CHNK N GOOD LOW NO CHANGE
MSTC 0 N/A 160 SF 98023-X MSTC FOR 98022 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 420 SF 98051-X PLAS N GOOD MOD NO CHANGE
ACT 0 N/A 160 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE
ROOM A303
OTHR N/A N/A 40 SF N/A LAB HOOD/NOT SAMPLED N GOOD LOW STAINLESS STEEL HOOD
PLAS-W 0 N/A 740 SF 98051-X PLAS N GOOD MOD NO CHANGE
BSBRD 0 N/A 40 SF 98058-X 4" BLK BSBRD N GOOD LOW NO CHANGE
MSTC 0 N/A 40 SF 98059-X MSTC FOR 98058 N GOOD LOW NO CHANGE
ACT 0 N/A 448 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
VFT <1 CHR 348 SF 98022-
1'X1' WHT W/GRY& BRN LG
CHNK N GOOD LOW NO CHANGE
MSTC 0 N/A 348 SF 98023- MSTC FOR 98022 N GOOD LOW NO CHANGE
ROOM A304
NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE
VFT <1 CHR 200 SF 98020-X
1'X1' WHT W/GRY& YEL LG
CHNK N GOOD LOW NO CHANGE
MSTC 0 N/A 200 SF 98021-X MSTC FOR 98020 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 510 SF 98051-X PLAS N GOOD MOD NO CHANGE
BSBRD 0 N/A 25 SF 98058-X 4" BLK BSBRD N GOOD LOW NO CHANGE
MSTC 0 N/A 25 SF 98059-X MSTC FOR 98058 N GOOD LOW NO CHANGE
ACT 0 N/A 220 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A305
PLAS-W 0 N/A 480 SF 98051-X PLAS N GOOD MOD NO CHANGE
PLAS-A 0 N/A 192 SF 98101-X PLAS N GOOD MOD NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
VFT <1 CHR 120 SF 98020-
1'X1' WHT W/GRY& YEL LG
CHNK N GOOD LOW NO CHANGE
MSTC 0 N/A 120 SF 98021- MSTC FOR 98020 N GOOD LOW NO CHANGE
BSBRD N/A N/A 100 LF N/A 6" TERAZZO BB N GOOD LOW PRESUMED
ROOM A306
NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE
DUCT N/A N/A 100 SF N/A DUCT INS NS N/A N/A N/A NO CHANGE
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
VFT <1 CHR 280 SF 98024-X 1'X1' GRN W/SM GRN STRK N GOOD LOW NO CHANGE
7 MSTC 5 CHR 280 SF 98025-X MSTC FOR 98024 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 970 SF 98051-X PLAS N GOOD MOD NO CHANGE
PLAS-A 0 N/A 448 SF 98101-X PLAS N GOOD MOD NO CHANGE
7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
PIPE F-STM 0 N/A 13 LF 98142-X ELBOW STEAM (FG PIPE) Y GOOD LOW NO CHANGE
PIPE F-STM 0 N/A 10 LF 98143-X ELBOW STEAM (FG PIPE) Y GOOD LOW NO CHANGE
7 PIPE-COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A309
VFT <1 CHR 350 SF 98024-X 1'X1' GRN W/SM GRN STRK N GOOD LOW NO CHANGE
7 MSTC 5 CHR 239 SF 98025-X MSTC FOR 98024 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 450 SF 98051-X PLAS N GOOD MOD NO CHANGE
BSBRD 0 N/A N/A 98058-X 4" BLK BSBRD N GOOD LOW NO CHANGE
MSTC 0 N/A N/A 98059-X MSTC FOR 98058 N GOOD LOW NO CHANGE
ACT 0 N/A 196 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A312
VFT 0 N/A 480 SF 98001-X 1'X1' TAN W/BRN& WHT NOT N GOOD LOW NO CHANGE
MSTC 0 N/A 480 SF 98001-X MSTC FOR 98001 LAB RESULT N GOOD LOW NO CHANGE
PLAS-W 0 N/A 700 SF 98051-X PLAS N GOOD MOD NO CHANGE
ACT 0 N/A 100 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE
ACT 0 N/A 200 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
4 PIPE-STM 70 CHR 11 LF 98137-X STEAM RISER Y GOOD LOW NO CHANGE
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
BSBRD N/A N/A 100 LF N/A 6" TERAZZO BB N GOOD LOW PRESUMED
ROOM A314
VFT <1 CHR 300 SF 98026-X 1'X1' GRY W/BLU & GRY NOT N GOOD LOW NO CHANGE
MSTC 0 N/A 300 SF 98027-X MSTC FOR 98026 N GOOD LOW NO CHANGE
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
PLAS-W 0 N/A 580 SF 98051-X PLAS N GOOD MOD NO CHANGE
BSBRD 0 N/A 25 SF 98058-X 4" BLK BSBRD N GOOD LOW NO CHANGE
MSTC 0 N/A 25 SF 98059-X MSTC FOR 98058 N GOOD LOW NO CHANGE
ACT 0 N/A 308 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A315
MSTC 0 N/A 460 SF 98001-X MSTC FOR 98001 LAB RESULT N GOOD LOW NO CHANGE
VFT 0 N/A 460 SF 98001-X 1'X1' TAN W/BRN& WHT MOT N GOOD LOW NO CHANGE
PLAS-W 0 N/A 720 SF 98051-X PLAS N GOOD MOD NO CHANGE
BSBRD 0 N/A 20 SF 98058-X 4" BLK BSBRD N GOOD LOW NO CHANGE
MSTC 0 N/A 20 SF 98059-X MSTC FOR 98058 N GOOD LOW NO CHANGE
ACT 0 N/A 450 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE
4 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A316
VFT <1 CHR 352 SF 98026-X 1'X1' GRY W/BLU & GRY MOT N GOOD LOW NO CHANGE
MSTC 0 N/A 352 SF 98027-X MSTC FOR 98026 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 600 SF 98051-X PLAS N GOOD MOD NO CHANGE
BSBRD 0 N/A 25 SF 98058-X 4" BLK BSBRD N GOOD LOW NO CHANGE
MSTC 0 N/A 25 SF 98059-X MSTC FOR 98058 N GOOD LOW NO CHANGE
ACT 0 N/A 330 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE
PIPE-DHW 0 N/A 20 LF 98129-X HW Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
4 PIPE-DCW 15 CHR 20 LF 98132-X CW Y GOOD LOW NO CHANGE
7 DEBRIS 65 CHR 10 SF 98135-X DEBRIS Y GOOD LOW NO CHANGE
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A316A
VFT <1 CHR 224 SF 98026-X 1'X1' GRY W/BLU & GRY NOT N GOOD LOW NO CHANGE
MSTC 0 N/A 224 SF 98027-X MSTC FOR 98026 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 460 SF 98051-X PLAS N GOOD MOD NO CHANGE
RANK FUNCTION FRIABLE COND POT FOR
Y/N DIST
ACT 0 N/A 208 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE
COUNTERTO
P N/A N/A 50 SF N/A BLACK COUNTERTOP N GOOD LOW NO CHANGE
ROOM A318
VFT <1 CHR 42 SF 98015-X 1'X1' BRN W/BRN & WHT STRK N GOOD LOW 1'X1' BLACK TILE
7 MSTC 25 CHR 42 SF 98017-X MSTC FOR 98015 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 210 SF 98051-X PLAS N GOOD MOD NO CHANGE
ACT 0 N/A 42 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE
7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings
ROOM A319
VFT <1 CHR 400 SF 98024-X 1'X1' WHT W/SM GRN STRK N GOOD LOW NO CHANGE
7 MSTC 5 CHR 400 SF 98025-X MSTC FOR 98024 N GOOD LOW NO CHANGE
PLAS-W 0 N/A 640 SF 98051-X PLAS N GOOD MOD NO CHANGE
BSBRD 0 N/A N/A 98052-X 4" TAN BSBRD N GOOD LOW NO CHANGE
MSTC 0 N/A N/A…