This is an asbestos survey document prepared by MC Consulting Inc. for Building 1. The document details the location and assessment of asbestos-containing materials (ACM) throughout the first floor of the building, organized by room and section. The survey identifies the specific areas where ACM is present, quantifies the percentage composition, categorizes the material type, and notes the quantity of samples collected. The assessment includes evaluations of whether materials are friable or non-friable, their current condition, and the potential for disturbance. Additional columns track reevaluation dates from 2010, relevant comments regarding the condition and location of materials, and ranking classifications to prioritize areas of concern.

This asbestos survey serves as a baseline assessment supporting the associated federal contract opportunity for Phase 2 repairs to Building 1's steam and condensate risers at a Department of Veterans Affairs Veterans Integrated Service Network 12 facility (Solicitation Number 36C25226B0012). The survey data is essential for contractors bidding on renovation or repair work, as it identifies locations where asbestos abatement or containment procedures must be implemented in compliance with federal and environmental regulations before mechanical work can proceed.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MC Consulting Inc. BLDG 1 SEC A 1ST FL

LOCATION ACM % TYPE QTY SAMPLE MATERIAL DESCRIPTION REEVALUATION 2010 COMMENTS

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

AREA 1ST FLOOR

ROOM Al

VFT <1 CHR 400 SF 98015-X 1'X1' TAN W/BRN & WHT STRK N GOOD LOW NO CHANGE

7 MSTC 30 CHR 400 SF 98016-X MSTC FOR 98015 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 928 SF 98051-X PLAS Y GOOD MOD NO CHANGE

ACT 0 N/A 400 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

ROOM A101

VFT <1 CHR 224 SF 98015-X 1'X1' TAN W/BR & WHT STRK N GOOD LOW NO CHANGE

7 MSTC 30 CHR 224 SF 98016-X MSTC FOR 98015 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 480 SF 98051-X PLAS Y GOOD MOD NO CHANGE

ACT 0 N/A 224 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y GOOD LOW NOT LISTED ON ORIGINAL

ACT 0 N/A 400 SF 98102-X 2'X4' WHT WORM Y GOOD LOW

ROOM A102

VFT <1 CHR 750 SF 98015-X 1'X1' TAN W/BRN & WHT STRK N GOOD LOW NO CHANGE

7 MSTC 30 CHR 750 SF 98016-X MSTC FOR 98015 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 1430 SF 98051-X PLAS Y GOOD MOD NO CHANGE

BSBRD 0 N/A 65 SF 98056-X 411 BRN BSBRD N GOOD LOW NO CHANGE

MSTC 0 N/A 27 SF 98057-X MSTC FOR 98056 N GOOD LOW NO CHANGE

ACT 0 N/A 750 SF 98103-X 1'X1' WHT WRM TILES Y GOOD LOW NO CHANGE

MSTC 0 N/A 750 SF 98105-X MSTC FOR 98103 N GOOD LOW NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

4 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

ROOM A103

VFT <1 CHR 235 SF 98015-X 1'X1' TAN W/BRN & WHT STRK N GOOD LOW NO CHANGE

7 MSTC 30 CHR 235 SF 98016-X MSTC FOR 98015 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 480 SF 98051-X PLAS Y GOOD MOD NO CHANGE

ACT 0 N/A 225 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW

LOCALIZED DAMAGE IN HALL OUTSIDE

OF RM 101

7 PIPE-STM 70 CHR 98137-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

4 PIPE-STM 70 CHR 11 LF 98137-X STEAM RISER Y GOOD LOW NO CHANGE

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

ROOM A104

VFT N/A N/A N/A N/A VFT N/A N/A N/A

12X12 GREY WITH CREAM FT NOT

LISTED ON ORIGINAL

MSTC N/A N/A N/A N/A MSTC N/A N/A N/A NOT LISTED ON ORIGINAL

BSBRD N/A N/A N/A N/A BSBRD N/A N/A N/A NOT LISTED ON ORIGINAL

NSINS N/A N/A N/A N/A NSINS N/A N/A N/A NO CHANGE

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

PLAS-W 0 N/A 560 SF 98051-X PLAS Y GOOD MOD NO CHANGE

PLAS-A 0 N/A 300 SF 98101-X PLAS Y GOOD MOD NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

VIB 0 N/A 98201-X VIB DAMP Y GOOD LOW NO CHANGE

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

ROOM A105

VFT <1 CHR 70 SF 98015-X 1'X1' TAN W/BRN & WHT STRK N GOOD LOW CARPET OVER FLOOR TILE

7 MSTC 30 CHR 70 SF 98016-X MSTC FOR 98015 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 432 SF 98051-X PLAS Y GOOD MOD NO CHANGE

ACT 0 N/A 180 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

4 PIPE-STM 70 CHR 11 LF 98137-X STEAM RISER Y GOOD LOW NO CHANGE

PIPE-

COND 70 CHR 98212-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

ROOM A106 NOT ACCESSIBLE

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NOT ACCESSIBLE

NSINS N/A N/A N/A N/A NSINS N/A N/A N/A NOT ACCESSIBLE

NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NOT ACCESSIBLE

PLAS-W 0 N/A 480 SF 98051-X PLAS Y GOOD MOD NOT ACCESSIBLE

PLAS-A 0 N/A 384 SF 98101-X PLAS Y GOOD MOD NOT ACCESSIBLE

7 PIPE-STM 70 CHR 98137-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

PIPE F-

STM 0 N/A N/A 98142-X STM FITG ON FIB PIPE Y GOOD LOW NOT ACCESSIBLE

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

7 VFT 12 CHR 384 SF 98009-

9"X9" LT BRN W/BLU & BRN

STRK N GOOD LOW NOT ACCESSIBLE

7 MSTC 10 CHR 384 SF 98010- MSTC FOR 98009 N GOOD LOW NOT ACCESSIBLE

PIPE F-

CON 0 N/A 10 LF 98158- COND FITG Y GOOD LOW NOT ACCESSIBLE

VIB 0 N/A N/A 98201- VIB DAMP N GOOD LOW NOT ACCESSIBLE

OTHR 0 N/A N/A 98202- GASKET (SEAL) N GOOD LOW NOT ACCESSIBLE

ROOM A106A

NSINS N/A N/A N/A N/A NSINS N/A N/A N/A NO CHANGE

7 VFT 25 CHR 24 SF 98002-X 9"X9" BLK W/WHTSTRK N GOOD LOW NO CHANGE

7 VFT 15 CHR 24 SF 98003-X 9"X9" GRY W/BLKSTRK N GOOD LOW NO CHANGE

7 MSTC 8 CHR 48 SF 98005-X MSTC FOR 98002,98003 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 308 SF 98051-X PLAS Y GOOD MOD NO CHANGE

PLAS-A 0 N/A 49 SF 98101-X PLAS Y GOOD MOD NO CHANGE

ROOM A107 NO CHANGE

NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

PLAS-W 0 136 SF 98051-X PLAS Y GOOD MOD NO CHANGE

PLAS-A 0 N/A 70 SF 98101-X PLAS Y GOOD MOD NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

ROOM A109 NOT ACCESSIBLE

VFT <1 CHR 242 SF 98015-X 1'X1' TAN W/BRN & WHT STRK N GOOD LOW NOT ACCESSIBLE

7 MSTC 30 CHR 242 SF 98016-X MSTC FOR 98015 N GOOD LOW NOT ACCESSIBLE

PLAS-W 0 N/A 528 SF 98051-X PLAS Y GOOD MOD NOT ACCESSIBLE

ACT 0 N/A 242 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NOT ACCESSIBLE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

ROOM A110

VFT <1 CHR 475 SF 98015-X 1'X1' TAN W/BRN & WHT STRK N GOOD LOW NO CHANGE

7 MSTC 30 CHR 475 SF 98016-X MSTC FOR 98015 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 512 SF 98051-X PLAS Y GOOD MOD NO CHANGE

ACT 0 N/A 240 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

PIPE-STM N/A N/A N/A N/A STEAM RISER N/A N/A N/A ABATED

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

ROOM A113

VFT <1 CHR 252 SF 98015-X 1'X1' TAN W/BRN & WHT STRK N GOOD LOW NO CHANGE

7 MSTC 30 CHR 252 SF 98016-X MSTC FOR 98015 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 512 SF 98051-X PLAS Y GOOD MOD NO CHANGE

ACT 0 N/A 252 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

4 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

ROOM A114

7 VFT 25 CHR 24 SF 98002-X 9"X9" BLK W/WHTSTRK N GOOD LOW NO CHANGE

7 VFT 15 CHR 24 SF 98003-X 9"X9" GRY W/BLKSTRK N GOOD LOW NO CHANGE

7 VFT 7 CHR N/A 98004-X 2'X.5 BLK BORDER TILE N GOOD LOW NO CHANGE

7 MSTC 8 CHR 54 SF 98005-X MSTC FOR 98002,98003,98004 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 338 SF 98051-X PLAS Y GOOD MOD NO CHANGE

PLAS-A 0 N/A 42 SF 98101-X PLAS Y GOOD MOD NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

ROOM A116

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A TERAZZO FLOOR BROWN

PLAS-W 0 N/A 550 SF 98051-X PLAS Y GOOD MOD NO CHANGE

PLAS-A 0 N/A 90 SF 98101-X PLAS Y GOOD MOD NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

ROOM A117

VFT <1 CHR 168 SF 98015-X 1'X1' TAN W/BRN & WHT STRK N GOOD LOW NO CHANGE

7 MSTC 30 CHR 168 SF 98016-X MSTC FOR 98015 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 384 SF 98051-X PLAS Y GOOD MOD NO CHANGE

BSBRD 0 N/A 24 SF 98056-X 4" BRN BSBRD N GOOD LOW NO CHANGE

MSTC 0 N/A 24 SF 98057-X MSTC FOR 98056 N GOOD LOW NO CHANGE

ACT 0 N/A 144 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

ROOM A118

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

VFT <1 CHR 760 SF 98015-X 1'X1' TAN W/BRN & WHT STRK N GOOD LOW NO CHANGE

7 MSTC 30 CHR 760 SF 98016-X MSTC FOR 98015 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 896 SF 98051-X PUS Y GOOD MOD NO CHANGE

ACT 0 N/A 768 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

4 PIPE-STM 70 CHR 11 LF 98137-X STEAM RISER Y GOOD LOW NO CHANGE

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

ROOM A119

VFT <1 CHR 420 SF 98015-X 1'X1' TAN W/BRN & WHT STRK N GOOD LOW NO CHANGE

7 MSTC 30 CHR 420 SF 98016-X MSTC FOR 98015 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 656 SF 98051-X PLAS Y GOOD MOD NO CHANGE

ACT 0 N/A 420 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

ROOM A122

VFT <1 CHR 168 SF 98015-X 1'X1' TAN W/BRN & WHT STRK N GOOD LOW NO CHANGE

7 MSTC 30 CHR 168 SF 98016-X MSTC FOR 98015 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 416 SF 98051-X PLAS Y GOOD MOD NO CHANGE

BSBRD 0 N/A 48 SF 98056-X 4" BRN BSBRD N GOOD LOW NO CHANGE

MSTC 0 N/A 48 SF 98057-X MSTC FOR 98056 N GOOD LOW NO CHANGE

ACT 0 N/A 168 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

ROOM A122A

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

WALL-BRD 0 N/A 192 SF 98055-X WALL BRD Y GOOD MOD NO CHANGE

PLAS-A 0 N/A 35 SF 98101-X PLAS N GOOD MOD NO CHANGE

ROOM A122B

VFT 0 N/A 40 SF 98001-X 1'X1' TAN W/TANMOT N GOOD LOW NO CHANGE

MSTC 0 N/A 40 SF 98001-X MSTC FOR 98001 LAB RESULT N GOOD LOW NO CHANGE

WALL-BRD 0 N/A 192 SF 98055-X WALL BRD NO CHANGE

ROOM A122B 12 SF 98056-X 4" BRN BSBRD

BSBRD 0 N/A N/A N/A BSBRD N GOOD LOW NO CHANGE

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

MSTC 0 N/A 11 SF 98057-X MSTC FOR 98056 N GOOD LOW NO CHANGE

ACT 0 N/A 35 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

ROOM A123

VFT <1 CHR 140 SF 98006-X 1'X1' TAN W/LG BRN STRKS N GOOD LOW NO CHANGE

7 MSTC 5 CHR 140 SF 98007-X MSTC FOR 98006 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 350 SF 98051-X PLAS Y GOOD MOD NO CHANGE

ACT 0 N/A 120 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

ROOM A124

VFT <1 CHR 288 SF 98006-X 1'X1' TAN W/LG BRN STRKS N GOOD LOW NO CHANGE

7 MSTC 5 CHR 288 SF 98007-X MSTC FOR 98006 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 544 SF 98051-X PLAS Y GOOD MOD NO CHANGE

PLAS-A 0 N/A 288 SF 98101-X PLAS Y GOOD MOD NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

4 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

7 DOOR 80 CHR 64 SF 98480-X ELEVATOR DOOR INS Y GOOD LOW NO CHANGE

ROOM A125

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

PLAS-W 0 N/A 320 SF 98051-X PLAS Y GOOD MOD NO CHANGE

ACT 0 N/A 96 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

ROOM A128

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A

12X12 FLOOR TILE AND MASTIC BELOW

CARPET

PLAS-W 0 N/A 560 SF 98051-X PLAS Y GOOD MOD NO CHANGE

ACT 0 N/A 286 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Presume behind walls & above ceilings

ROOM A129A

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

PLAS-W 0 N/A 736 SF 98051-X PLAS Y GOOD MOD NO CHANGE

ACT 0 N/A 448 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

4 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Presume behind walls & above ceilings

ROOM A132

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

ROOM A132

VFT <1 CHR 440 SF 98006-X 1'X1' TAN W/LG BRN STRKS N GOOD LOW NO CHANGE

7 MSTC 5 CHR 440 SF 98007-X MSTC FOR 98006 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 720 SF 98051-X PLAS Y GOOD MOD NO CHANGE

ACT 0 N/A 506 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

ROOM A133

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

PLAS-W 0 N/A 448 SF 98051-X PLAS Y GOOD MOD NO CHANGE

ACT 0 N/A 196 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

4 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW NO CHANGE

ROOM A133A

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

PLAS-W 0 N/A 640 SF 98051-X PLAS Y GOOD MOD NO CHANGE

ACT 0 N/A 350 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

4 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

ROOM A134

NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

NSINS N/A N/A N/A N/A NSINS N/A N/A N/A NO CHANGE

PLAS-W 0 N/A 736 SF 98051-X PLAS Y GOOD MOD NO CHANGE

PLAS-A 0 N/A 168 SF 98101-X PLAS Y GOOD MOD NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

OTHR 0 N/A N/A 98202-X GASKET (SEAL) N GOOD LOW NO CHANGE

ROOM A136

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

PLAS-W 0 N/A 384 SF 98051-X PLAS Y GOOD MOD NO CHANGE

PLAS-A 0 N/A 64 SF 98101-X PLAS Y GOOD MOD NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

ROOM A138

NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

PLAS-W 0 N/A 416 SF 98051-X PLAS Y GOOD MOD NO CHANGE

ROOM A148

7 VFT 25 CHR 96 SF 98002- 9"X9" BLK W/WHTSTRK N GOOD LOW NO CHANGE

7 VFT 15 CHR 96 SF 98003- 9"X9" GRY W/BLKSTRK N GOOD LOW NO CHANGE

7 VFT 7 CHR 10 SF 98004- 2'X.5 BLK BORDER TILE N GOOD LOW NO CHANGE

7 MSTC 8 CHR 200 SF 98005- MSTC FOR 98002,98003,98004 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 768 SF 98051- PLAS Y GOOD MOD NO CHANGE

OTHR 0 N/A 768 SF 98054- RED BRICK NO CHANGE

PLAS-A 0 N/A 190 SF 98101- PLAS-A Y GOOD MOD NO CHANGE

PIPE F-

DCW 0 N/A N/A 98151- CW Y GOOD LOW NO CHANGE

PIPE-STM 0 N/A 20 LF 98152- STEAM/DEAD LINE Y GOOD LOW NO CHANGE

1 PIPE-DHW 70 CHR 30 LF 98153- HW Y GOOD LOW NO CHANGE

PIPE-STM 0 30 LF 98154- STEAM/DEAD LINE Y GOOD LOW NO CHANGE

PIPE-

COND 50 CHR 30 LF 98155- COND Y GOOD LOW NO CHANGE

ROOM AlA

VFT <1 CHR 144 SF 98006-X 1'X1' TAN W/LG BRN STRKS N GOOD LOW NO CHANGE

7 MSTC 5 CHR 144 SF 98007-X MSTC FOR 98006 N GOOD LOW NO CHANGE

VFT <1 CHR 192 SF 98015-X 1'X1' TAN W/BRN & WHT STRK N GOOD LOW NO CHANGE

7 MSTC 30 CHR 192 SF 98016-X MSTC FOR 98015 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 800 SF 98051-X PLAS Y GOOD MOD NO CHANGE

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

ACT 0 N/A 336 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

ROOM A18 NO CHANGE

VFT <1 CHR 1040 SF 98006-X 1'X1' TAN W/LG BRN STRKS N GOOD LOW NO CHANGE

7 MSTC 5 CHR 1040 SF 98007-X MSTC FOR 98006 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 2210 SF 98051-X PLAS Y GOOD MOD NO CHANGE

ACT 0 N/A 1040 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

VFT <1 CHR 176 SF 98006- 1'X1' TAN W/LG BRN STRKS N GOOD LOW NO CHANGE

7 MSTC 5 CHR 176 SF 98007- MSTC FOR 98006 N GOOD LOW NO CHANGE

BSBRD 0 N/A 46 SF 98056- 4" BRN BSBRD N GOOD LOW NO CHANGE

MSTC 0 N/A 48 SF 98057- MSTC FOR 98056 N GOOD LOW NO CHANGE

ROOM A138

PLAS-A 0 N/A 168 SF 98101-X PLAS Y GOOD MOD NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

ROOM A140

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE

PLAS-W 0 N/A 416 SF 98051-X PLAS Y GOOD MOD NO CHANGE

PLAS-A 0 N/A 168 SF 98101-X PLAS Y GOOD MOD NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

ROOM A141

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

ROOM A142

NSFM N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

PLAS-W 0 N/A 336 SF 98051-X PLAS Y GOOD MOD NO CHANGE

ACT 0 N/A 110 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

BSBRD 0 N/A 30 SF .98052- 4" TAN BSBRD N GOOD LOW NO CHANGE

MSTC 0 N/A 30 SF 98053- MSTC FOR 98052 N GOOD LOW NO CHANGE

WALL-BRD 0 N/A 80 SF 98055- WALL BRD Y GOOD MOD NO CHANGE

OTHR 0 N/A 10 SF 98343- WALL BRD TAPE Y GOOD LOW NO CHANGE

ROOM A142A

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

MSTC 0 N/A 1496 SF 98001-X MSTC FOR 98001 LAB RESULT N GOOD LOW NO CHANGE

PLAS-W 0 N/A 1250 SF 98051-X PLAS Y GOOD MOD NO CHANGE

BSBRD N/A 20 SF 98052-X 4" TAN BSBRD N GOOD LOW NO CHANGE

MSTC N/A 20 SF 98053-X MSTC FOR 98052 N GOOD LOW NO CHANGE

4 PIPE-STM 70 CHR 33 LF 98137-X STEAM RISER NO CHANGE

VFT 0 N/A 1496 SF 98001- 1'X1' TAN W/TANMOT N GOOD LOW NO CHANGE

ACT N/A 1500 SF 98102- 2'X4' WHT WORM Y GOOD LOW NO CHANGE

PIPE F-

STM 60 CHR N/A 98156- STM FITG Y GOOD LOW NO CHANGE

PIPE F-

CON 40 CHR N/A 98157- COND FITG Y GOOD LOW NO CHANGE

ROOM A142B

VFT <1 CHR 156 SF 98006-X 1'X1' TAN W/LG BRN STRKS N GOOD LOW NO CHANGE

7 MSTC 5 CHR 156 SF 98007-X MSTC FOR 98006 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 368 SF 98051-X PLAS Y GOOD MOD NO CHANGE

ACT 0 N/A 130 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

ROOM A143 NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y GOOD LOW Presume behind walls & above ceilings

Abated Date Work Order Project No. Report Point of Contact Notes

MC Consulting Inc. BLDG 1 SEC A 2ND FL

LOCATION ACM % TYPE QTY SAMPLE MATERIAL DESCRIPTION COMMENTS

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

AREA 2ND FLOOR

ROOM A2

MSTC 0 N/A 640 SF 98011-X MSTC FOR 98008 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 1410 SF 98051-X PLAS N GOOD MOD NO CHANGE

ACT 0 N/A 640 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

ROOM A201

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE

7 VFT 1 CHR 224 SF 98014-X 1'X1' WHT W/BLU STRKS N GOOD LOW CARPET OVER FLOORING

7 MSTC 30 CHR 224 SF 98016-X MSTC FOR 98014 N GOOD LOW CARPET OVER FLOORING

ACT 0 N/A 224 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A201A

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE

VFT 1 CHR 240 SF 98014-X 1'X1' WHT W/BLU STRKS N GOOD LOW CARPET OVER FLOORING

MSTC 30 CHR 240 SF 98016-X MSTC FOR 98014 N GOOD LOW CARPET OVER FLOORING

PLAS-W 0 N/A 500 SF 98051-X PLAS N GOOD MOD NO CHANGE

ACT 0 N/A 195 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

ACT 0 N/A 195 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A202

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A CARPET OVER FLOORING

PLAS-W 0 N/A 480 SF 98051-X PLAS N GOOD MOD NO CHANGE

WALL-BRD 0 N/A 480 SF 98055-X WALL BRD N GOOD MOD NO CHANGE

ACT 0 N/A 224 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A202A

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

PLAS-W 0 N/A 480 SF 98051-X PLAS N GOOD MOD NO CHANGE

REEVALUATION 2010

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

REEVALUATION 2010

WALL-BRD 0 N/A 480 SF 98055-X WALL BRD N GOOD MOD NO CHANGE

ACT 0 N/A 224 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A202B

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

PLAS-W 0 N/A 450 SF 98051-X PLAS N GOOD MOD NO CHANGE

WALL-BRD 0 N/A 450 SF 98055-X WALL BRD N GOOD MOD NO CHANGE

ACT 0 N/A 195 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A204

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE

PLAS-W 0 N/A 640 SF 98051-X PLAS N GOOD MOD NO CHANGE

BSBRD 0 N/A N/A 98058-X 4" BLK BSBRD N GOOD LOW 6" BLK BSBRD

MSTC 0 N/A N/A 98059-X MSTC FOR 98058 N GOOD LOW NO CHANGE

PLAS-A 0 N/A 375 SF 98101-X PLAS N GOOD MOD NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A205

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A CARPET OVER FLOORING

PLAS-W 0 N/A 480 SF 98051-X PLAS N GOOD MOD NO CHANGE

ACT 0 N/A 224 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A206

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

REEVALUATION 2010

NSINS N/A N/A N/A N/A NSINS N/A N/A N/A NO CHANGE

NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

PLAS-W 0 N/A 670 SF 98051-X PLAS N GOOD MOD NO CHANGE

PLAS-A 0 N/A 416 SF 98101-X PLAS N GOOD MOD NO CHANGE

PIPE-DCW 0 N/A 11 LF 98128-X CW Y GOOD LOW NO CHANGE

PIPE-DHW 0 N/A 30 LF 98129-X HW Y GOOD LOW LOCALIZED DAMAGE

4 PIPE-DCW 15 CHR 30 LF 98132-X CW Y GOOD LOW LOCALIZED DAMAGE

1 DEBRIS 65 CHR 30 SF 98135-X PIPE DEBRIS Y NO CHANGE

4 PIPE-STM 70 CHR 11 LF 98137-X STEAM RISER Y GOOD LOW NO CHANGE

OTHR 0 N/A N/A 98202-X GASKET N GOOD LOW NO CHANGE

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

VFT 0 N/A 195 SF 98012- BRN FLOOR SHEET N GOOD LOW NO CHANGE

MSTC 0 N/A 195 SF 98013- MSTC FOR 98012 N GOOD LOW NO CHANGE

VIB 0 N/A N/A 98201- VIB DAM N GOOD LOW NO CHANGE

ROOM A207

7 VFT 1 CHR 92 SF 98014-X 1'X1' WHT W/BLU STRKS N GOOD LOW NO CHANGE

7 MSTC 30 CHR 92 SF 98016-X MSTC FOR 98014 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 320 SF 98051-X PLAS N GOOD MOD NO CHANGE

BSBRD 0 N/A N/A 98061-X 6" BRN BSBRD N GOOD LOW NO CHANGE

MSTC 0 N/A N/A 98062-X MSTC FOR 98061 N GOOD LOW NO CHANGE

PLAS-A 0 N/A 84 SF 98101-X PLAS N GOOD MOD NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X W-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A209 ROOM COMBINED WITH 211

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE

PLAS-W 0 N/A 400 SF 98051-X PLAS N GOOD MOD NO CHANGE

ACT 0 N/A 150 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

REEVALUATION 2010

ROOM A211

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE

PLAS-W 0 N/A 420 SF 98051-X PLAS N GOOD MOD NO CHANGE

ACT 0 N/A 168 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CUR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A212

PLAS-W 0 N/A 580 SF 98051-X PLAS N GOOD MOD NO CHANGE

ACT 0 N/A 320 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

VFT <1 CHR 320 SF 98015- 1'X1' TAN W/WHT & BRN STRKS N GOOD LOW NO CHANGE

7 MSTC 25 CHR 320 SF 98017- MSTC FOR 98015 N GOOD LOW NO CHANGE

ROOM A213

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

PLAS-W 0 N/A 420 SF 98051-X PLAS N GOOD MOD NO CHANGE

ACT 0 N/A 192 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A214

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

REEVALUATION 2010

TRANSITE

FUME

HOOD N/A N/A 60 SF N/A TRANSITE FUME HOOD N GOOD LOW Presume

BLACK

TABLETOP N/A N/A 100 SF N/A BLACK TABLETOP N GOOD LOW Presume

7 VFT 1 CHR 336 SF 98014-X 1'X1' WHT W/BLU STRKS N GOOD LOW NO CHANGE

7 MSTC 30 CHR 336 SF 98016-X MSTC FOR 98014 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 610 SF 98051-X PLAS N GOOD MOD NO CHANGE

ACT 0 N/A 336 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A216

VFT <1 CHR 400 SF 98022-X 1'X1' WHT W/GRY& BRN LG CHNK N GOOD LOW NO CHANGE

MSTC 0 N/A 400 SF 98023-X MSTC FOR 98022 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 660 SF 98051-X PLAS N GOOD MOD NO CHANGE

ACT 0 N/A 400 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A217

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A CARPET OVER FLOORING

PLAS-W 0 N/A 420 SF 98051-X PLAS N GOOD MOD NO CHANGE

BSBRD 0 N/A N/A 98061-X 6" BRN BSBRD N GOOD LOW 3" BLACK BSBRD

MSTC 0 N/A N/A 98062-X MSTC FOR 98061 N GOOD LOW NO CHANGE

ACT 0 N/A 168 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

REEVALUATION 2010

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A218

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A

PLAS-W 0 N/A 450 SF 98051-X PLAS N GOOD MOD NO CHANGE

ACT 0 N/A 192 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

PIPE-DHW 0 N/A 11 LF 98129-X HW Y GOOD LOW NO CHANGE

4 PIPE-DCW 15 CHR 11 LF 98132-X CW Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A218A

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

PLAS-W 0 N/A 224 SF 98051-X PUS N GOOD MOD NO CHANGE

PLAS-A 0 N/A 48 SF 98101-X PLAS N GOOD MOD NO CHANGE

ROOM A219

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A CARPET OVER LEVELER

PLAS-W 0 N/A 660 SF 98051-X PLAS N GOOD MOD NO CHANGE

BSBRD 0 N/A 22 SF 98061-X 6" BRN BSBRD N GOOD LOW 3" BLACK BSBRD

MSTC 0 N/A 22 SF 98062-X MSTC FOR 98061 N GOOD LOW NO CHANGE

ACT 0 N/A 420 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

ACT 0 N/A 420 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A220

VFT <1 N/A 288 SF 98006-X 1'X1' TAN W/LG BRN STRKS N GOOD LOW NO CHANGE

7 MSTC 5 CHR 288 SF 98007-X MSTC FOR 98006 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 544 SF 98051-X PLAS N GOOD MOD NO CHANGE

PLAS-A 0 N/A 288 SF 98101-X PLAS N GOOD MOD NO CHANGE

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

REEVALUATION 2010

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

4 PIPE-STM 70 CHR 11 LF 98137-X STEAM Y GOOD LOW NO CHANGE

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 DOOR 80 CHR 64 SF 98480-X ELEVATOR DOOR INS Y GOOD LOW NO CHANGE

ROOM 223

VFT N/A N/A 200 SF N/A BROWN N GOOD LOW Presumed

TERRAZZ

O BB N/A N/A 100 SF N/A 6" BROWN N GOOD LOW Presumed

ROOM A224

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

PLAS-W 0 N/A 624 SF 98051-X PLAS N GOOD MOD NO CHANGE

ACT 0 N/A 360 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

4 PIPE-STM 70 CHR 11 LF 98137-X STEAM Y GOOD LOW NO CHANGE

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 VFT 1 CHR 519 SF 98014- 1'X1' WHT W/BLU STRKS N GOOD LOW NO CHANGE

7 MSTC 30 CHR 519 SF 98016- MSTC FOR 98014 N GOOD LOW NO CHANGE

ROOM A225

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A CARPET OVER FLOOR TILE

PLAS-W 0 N/A 350 SF 98051-X PLAS N GOOD MOD NO CHANGE

BSBRD 0 N/A N/A 98061-X 6" BRN BSBRD N GOOD LOW NO CHANGE

MSTC 0 N/A N/A 98062-X MSTC FOR 98061 N GOOD LOW NO CHANGE

ACT 0 N/A 112 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM 227

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

REEVALUATION 2010

CARPET

OVER FT NOT LISTED ON ORIGINAL

ROOM A228

BLACK

TRANSITE

WORKBEN

CH N/A N/A 100 SF N/A BLACK TRANSITE WORKBENCH N GOOD LOW Presumed

VFT <1 CHR 432 SF 98015-X 1'X1' TAN W/WHT & BRN STRKS N GOOD LOW NO CHANGE

7 MSTC 25 CHR 432 SF 98017-X MSTC FOR 98015 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 670 SF 98051-X PLAS N GOOD MOD NO CHANGE

BSBRD 0 N/A 20 SF 98058-X 4" BLK BSBRD N GOOD LOW NO CHANGE

MSTC 0 N/A 20 SF 98059-X MSTC FOR 98058 N GOOD LOW NO CHANGE

ACT 0 N/A 432 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A229

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A CARPET

PLAS-W 0 N/A 350 SF 98051-X PLAS N GOOD MOD NO CHANGE

BSBRD 0 N/A N/A 98061-X 6" BRN BSBRD N GOOD LOW NO CHANGE

MSTC 0 N/A N/A 98062-X MSTC FOR 98061 N GOOD LOW NO CHANGE

ACT 0 N/A 120 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A230

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

NSINS N/A N/A N/A N/A NSINS N/A N/A N/A NO CHANGE

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

REEVALUATION 2010

PLAS-W 0 500 SF 98051-X PLAS N GOOD MOD NO CHANGE

PLAS-A 0 240 SF 98101-X PLAS N GOOD MOD NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

OTHR 0 N/A N/A 98202-X GASKET N GOOD LOW NO CHANGE

VIB 0 N/A N/A 98207-X VIB DAM N GOOD LOW NO CHANGE

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

OTHR 0 N/A 75 SF 98203- DUCT COVER N GOOD LOW NO CHANGE

ROOM A231

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A CARPET OVER LEVELER

ROOM A231

NSINS N/A N/A N/A N/A NSINS N/A N/A N/A NO CHANGE

PLAS-W 0 N/A 400 SF 98051-X PLAS N GOOD MOD NO CHANGE

BSBRD 0 N/A 15 SF 98061-X 6" BRN BSBRD N GOOD LOW 3" BLACK BSBRD

MSTC 0 N/A 15 SF 98062-X MSTC FOR 98061 N GOOD LOW NO CHANGE

ACT 0 N/A 154 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A232

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A BROWN VINYL FLOORING

PLAS-W 0 N/A 350 SF 98051-X PLAS N GOOD MOD NO CHANGE

PLAS-A 0 N/A 64 SF 98101-X PLAS N GOOD MOD NO CHANGE

ROOM A234

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NO CHANGE

PLAS-A 0 N/A 24 SF 98101-X PLAS N GOOD MOD NO CHANGE

ACT 0 N/A 160 SF 98103-X 1'X1' WHT WRM TILES . Y GOOD LOW 2X4 CT ON WALLS

MSTC 0 N/A 160 SF 98105-X MSTC FOR 98103 N GOOD LOW NO CHANGE

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

REEVALUATION 2010

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A235

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A

PLAS-W 0 N/A 700 SF 98051-X PLAS N GOOD MOD NO CHANGE

ACT 0 N/A 420 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

4 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

BSBRD 0 N/A 35 SF 98061- 6" BRN BSBRD N GOOD LOW NO CHANGE

MSTC 0 N/A 35 SF 98062- MSTC FOR 98061 N GOOD LOW NO CHANGE

ROOM A236

NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE

VFT 0 N/A 224 SF 98008-X 1'X1' WHT W/BRN CHNK N GOOD LOW NO CHANGE

MSTC 0 N/A 224 SF 98011-X MSTC FOR 98008 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 480 SF 98051-X PLAS N GOOD MOD NO CHANGE

ACT 0 N/A 224 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A238

6"

TERRAZZ

O BB N/A N/A 100 SF N/A 6" TERRAZZO BB N GOOD LOW Presumed

BLACK

TABLETOP N/A N/A 100 SF N/A BLACK TABLETOP N GOOD LOW Presumed

7 VFT 1 CHR 544 SF 98014-X 1'X1' WHT W/BLU STRKS N GOOD LOW NO CHANGE

7 MSTC 30 CHR 544 SF 98016-X MSTC FOR 98014 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 800 SF 98051-X PLAS N GOOD MOD NO CHANGE

ACT 0 N/A 544 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

REEVALUATION 2010

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

BSBRD 0 N/A 10 SF 98058- 4" BLK BSBRD N GOOD LOW NO CHANGE

MSTC 0 N/A 10 SF 98059- MSTC FOR 98058 N GOOD LOW NO CHANGE

ROOM A239

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A CARPET OVER FT

PLAS-W 0 N/A 350 SF 98051-X PLAS N GOOD MOD NO CHANGE

BSBRD 0 N/A 28 SF 98061-X 6" BRN BSBRD N GOOD LOW NO CHANGE

MSTC 0 N/A 28 SF 98062-X MSTC FOR 98061 N GOOD LOW NO CHANGE

ACT 0 N/A 112 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A240

6"

TERRAZZ

O BB N/A N/A 100 SF N/A 6" TERRAZZO BB N GOOD LOW Presumed

SINK

UNDERCO

ATING N/A N/A 50 SF N/A SINK UNDERCOATING N GOOD MOD Presumed

7 VFT 1 CHR 480 SF 98014-X 1'X1' WHT W/BLU STRKS N GOOD LOW NO CHANGE

7 MSTC 30 CHR 480 SF 98016-X MSTC FOR 98016 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 800 SF 98051-X PLAS N GOOD MOD NO CHANGE

ACT 0 N/A 480 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A241

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

REEVALUATION 2010

6"

TERRAZZ

O BB N/A N/A 100 SF N/A 6" TERRAZZO BB N GOOD LOW Presumed

VFT <1 CHR 200 SF 98015-X 1'X1' TAN W/WHT & BRN STRKS N GOOD LOW CARPET OVER FT

7 MSTC 25 CHR 200 SF 98017-X MSTC FOR 98015 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 480 SF 98051-X PLAS N GOOD MOD NO CHANGE

ACT 0 N/A 200 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

4 PIPE-STM 70 CHR 11 LF 98137-X STEAM Y GOOD LOW NO CHANGE

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A241A

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A242 COMBINED WITH RM 246

VFT <1 CHR 612 SF 98022-X 1'X1' WHT W/GRY& BRN LG CHNK N GOOD LOW NO CHANGE

MSTC 0 N/A 612 SF 98023-X MSTC FOR 98022 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 830 SF 98051-X PLAS N GOOD MOD NO CHANGE

BSBRD 0 N/A 50 SF 98061-X 6" BRN BSBRD N GOOD LOW NO CHANGE

MSTC 0 N/A 50 SF 98062-X MSTC FOR 98061 N GOOD LOW NO CHANGE

ACT 0 N/A 612 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A243

NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NEW GEY 12X12 FT

VFT 0 N/A 144 SF 98008-X 1'X1' WHT W/BRN CHNK N GOOD LOW NO CHANGE

MSTC 0 N/A 144 SF 98011-X MSTC FOR 98008 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 380 SF 98051-X PLAS N GOOD MOD NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE-

COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM 245

NSFM N/A N/A N/A N/A NSFM N/A N/A N/A NOT LISTED ON ORIGINAL

ROOM A2A

6"

TERRAZZ

O BB N/A N/A 100 SF N/A 6" TERRAZZO BB N GOOD LOW Presumed

PLAS-W 0 N/A 580 SF 98051-X PLAS N GOOD MOD NO CHANGE

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

REEVALUATION 2010

ACT 0 N/A 192 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

VFT 0 N/A 192 SF 98008- 1'X1' WHT W/BRN CHNK N GOOD LOW NO CHANGE

MSTC 0 N/A 192 SF 98011- MSTC FOR 98008 N GOOD LOW NO CHANGE

ROOM A2B

PLAS-W 0 N/A 620 SF 98051-X PLAS N GOOD MOD NO CHANGE

ACT 0 N/A 960 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

4 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

VFT <1 CHR 126 SF 98018- 1'X1' OFF WHT W/GRY & TAN STRK N GOOD LOW NO CHANGE

7 MSTC 15 CHR 126 SF 98019- MSTC FOR 98018 N GOOD LOW NO CHANGE

ACT 0 224 SF 98104- 2'X4' GRY WRM W/PNHL Y GOOD LOW NO CHANGE

MC Consulting Inc. BLDG 1 SEC A 3RD FL

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

AREA 3RD FLOOR

ROOM A3

VFT 0 N/A 640 SF 98008-X 1'X1' WHT W/BRN CHNK N GOOD LOW NO CHANGE

MSTC 0 N/A 640 SF 98011-X MSTC FOR 98008 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 1410 SF 98051-X PLAS N GOOD MOD NO CHANGE

ACT 0 N/A 640 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE

4 PIPE-DHW 4 CHR 80 LF 98150-X HW Y GOOD LOW NO CHANGE

ROOM A300

OTHR N/A N/A 90 SF N/A LAB HOOD/NOT SAMPLED N GOOD LOW STAINLESS STEEL HOOD

BSBRD 0 N/A 20 SF 98058-X 4 BLK BSBRD N GOOD LOW NO CHANGE

VFT N/A N/A N/A N/A VFT N GOOD LOW NO CHANGE

7 MSTC 5 CHR 240 SF 98025-X MSTC FOR 98024 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 460 SF 98051-X PLAS N GOOD MOD NO CHANGE

ACT 0 N/A 210 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A302

NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE

VFT 0 N/A 160 SF 98008-X 1'X1' WHT W/BRN CHNK N GOOD LOW NO CHANGE

MSTC 0 N/A 640 SF 98011-X MSTC FOR 98008 N GOOD LOW NO CHANGE

VFT <1 CHR 160 SF 98022-X

1'X1' WHT W/GRY& BRN LG

CHNK N GOOD LOW NO CHANGE

MSTC 0 N/A 160 SF 98023-X MSTC FOR 98022 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 420 SF 98051-X PLAS N GOOD MOD NO CHANGE

ACT 0 N/A 160 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE

ROOM A303

OTHR N/A N/A 40 SF N/A LAB HOOD/NOT SAMPLED N GOOD LOW STAINLESS STEEL HOOD

PLAS-W 0 N/A 740 SF 98051-X PLAS N GOOD MOD NO CHANGE

BSBRD 0 N/A 40 SF 98058-X 4" BLK BSBRD N GOOD LOW NO CHANGE

MSTC 0 N/A 40 SF 98059-X MSTC FOR 98058 N GOOD LOW NO CHANGE

ACT 0 N/A 448 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

VFT <1 CHR 348 SF 98022-

1'X1' WHT W/GRY& BRN LG

CHNK N GOOD LOW NO CHANGE

MSTC 0 N/A 348 SF 98023- MSTC FOR 98022 N GOOD LOW NO CHANGE

ROOM A304

NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE

VFT <1 CHR 200 SF 98020-X

1'X1' WHT W/GRY& YEL LG

CHNK N GOOD LOW NO CHANGE

MSTC 0 N/A 200 SF 98021-X MSTC FOR 98020 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 510 SF 98051-X PLAS N GOOD MOD NO CHANGE

BSBRD 0 N/A 25 SF 98058-X 4" BLK BSBRD N GOOD LOW NO CHANGE

MSTC 0 N/A 25 SF 98059-X MSTC FOR 98058 N GOOD LOW NO CHANGE

ACT 0 N/A 220 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A305

PLAS-W 0 N/A 480 SF 98051-X PLAS N GOOD MOD NO CHANGE

PLAS-A 0 N/A 192 SF 98101-X PLAS N GOOD MOD NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

VFT <1 CHR 120 SF 98020-

1'X1' WHT W/GRY& YEL LG

CHNK N GOOD LOW NO CHANGE

MSTC 0 N/A 120 SF 98021- MSTC FOR 98020 N GOOD LOW NO CHANGE

BSBRD N/A N/A 100 LF N/A 6" TERAZZO BB N GOOD LOW PRESUMED

ROOM A306

NSWM N/A N/A N/A N/A NSWM N/A N/A N/A NO CHANGE

DUCT N/A N/A 100 SF N/A DUCT INS NS N/A N/A N/A NO CHANGE

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

VFT <1 CHR 280 SF 98024-X 1'X1' GRN W/SM GRN STRK N GOOD LOW NO CHANGE

7 MSTC 5 CHR 280 SF 98025-X MSTC FOR 98024 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 970 SF 98051-X PLAS N GOOD MOD NO CHANGE

PLAS-A 0 N/A 448 SF 98101-X PLAS N GOOD MOD NO CHANGE

7 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

PIPE F-STM 0 N/A 13 LF 98142-X ELBOW STEAM (FG PIPE) Y GOOD LOW NO CHANGE

PIPE F-STM 0 N/A 10 LF 98143-X ELBOW STEAM (FG PIPE) Y GOOD LOW NO CHANGE

7 PIPE-COND 70 CHR N/A 98212-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A309

VFT <1 CHR 350 SF 98024-X 1'X1' GRN W/SM GRN STRK N GOOD LOW NO CHANGE

7 MSTC 5 CHR 239 SF 98025-X MSTC FOR 98024 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 450 SF 98051-X PLAS N GOOD MOD NO CHANGE

BSBRD 0 N/A N/A 98058-X 4" BLK BSBRD N GOOD LOW NO CHANGE

MSTC 0 N/A N/A 98059-X MSTC FOR 98058 N GOOD LOW NO CHANGE

ACT 0 N/A 196 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A312

VFT 0 N/A 480 SF 98001-X 1'X1' TAN W/BRN& WHT NOT N GOOD LOW NO CHANGE

MSTC 0 N/A 480 SF 98001-X MSTC FOR 98001 LAB RESULT N GOOD LOW NO CHANGE

PLAS-W 0 N/A 700 SF 98051-X PLAS N GOOD MOD NO CHANGE

ACT 0 N/A 100 SF 98102-X 2'X4' WHT WORM Y GOOD LOW NO CHANGE

ACT 0 N/A 200 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

4 PIPE-STM 70 CHR 11 LF 98137-X STEAM RISER Y GOOD LOW NO CHANGE

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

BSBRD N/A N/A 100 LF N/A 6" TERAZZO BB N GOOD LOW PRESUMED

ROOM A314

VFT <1 CHR 300 SF 98026-X 1'X1' GRY W/BLU & GRY NOT N GOOD LOW NO CHANGE

MSTC 0 N/A 300 SF 98027-X MSTC FOR 98026 N GOOD LOW NO CHANGE

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

PLAS-W 0 N/A 580 SF 98051-X PLAS N GOOD MOD NO CHANGE

BSBRD 0 N/A 25 SF 98058-X 4" BLK BSBRD N GOOD LOW NO CHANGE

MSTC 0 N/A 25 SF 98059-X MSTC FOR 98058 N GOOD LOW NO CHANGE

ACT 0 N/A 308 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A315

MSTC 0 N/A 460 SF 98001-X MSTC FOR 98001 LAB RESULT N GOOD LOW NO CHANGE

VFT 0 N/A 460 SF 98001-X 1'X1' TAN W/BRN& WHT MOT N GOOD LOW NO CHANGE

PLAS-W 0 N/A 720 SF 98051-X PLAS N GOOD MOD NO CHANGE

BSBRD 0 N/A 20 SF 98058-X 4" BLK BSBRD N GOOD LOW NO CHANGE

MSTC 0 N/A 20 SF 98059-X MSTC FOR 98058 N GOOD LOW NO CHANGE

ACT 0 N/A 450 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE

4 PIPE-STM 70 CHR N/A 98137-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A316

VFT <1 CHR 352 SF 98026-X 1'X1' GRY W/BLU & GRY MOT N GOOD LOW NO CHANGE

MSTC 0 N/A 352 SF 98027-X MSTC FOR 98026 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 600 SF 98051-X PLAS N GOOD MOD NO CHANGE

BSBRD 0 N/A 25 SF 98058-X 4" BLK BSBRD N GOOD LOW NO CHANGE

MSTC 0 N/A 25 SF 98059-X MSTC FOR 98058 N GOOD LOW NO CHANGE

ACT 0 N/A 330 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE

PIPE-DHW 0 N/A 20 LF 98129-X HW Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

4 PIPE-DCW 15 CHR 20 LF 98132-X CW Y GOOD LOW NO CHANGE

7 DEBRIS 65 CHR 10 SF 98135-X DEBRIS Y GOOD LOW NO CHANGE

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A316A

VFT <1 CHR 224 SF 98026-X 1'X1' GRY W/BLU & GRY NOT N GOOD LOW NO CHANGE

MSTC 0 N/A 224 SF 98027-X MSTC FOR 98026 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 460 SF 98051-X PLAS N GOOD MOD NO CHANGE

RANK FUNCTION FRIABLE COND POT FOR

Y/N DIST

ACT 0 N/A 208 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE

COUNTERTO

P N/A N/A 50 SF N/A BLACK COUNTERTOP N GOOD LOW NO CHANGE

ROOM A318

VFT <1 CHR 42 SF 98015-X 1'X1' BRN W/BRN & WHT STRK N GOOD LOW 1'X1' BLACK TILE

7 MSTC 25 CHR 42 SF 98017-X MSTC FOR 98015 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 210 SF 98051-X PLAS N GOOD MOD NO CHANGE

ACT 0 N/A 42 SF 98104-X 2'X4' GRY (LT) WRM W/PNHL Y GOOD LOW NO CHANGE

7 PIPE-DCW 15 CHR N/A 98132-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

7 PIPE-DHW 70 CHR N/A 98153-X N-ACC ASSUMED POSITIVE Y N/A LOW Presume behind walls & above ceilings

ROOM A319

VFT <1 CHR 400 SF 98024-X 1'X1' WHT W/SM GRN STRK N GOOD LOW NO CHANGE

7 MSTC 5 CHR 400 SF 98025-X MSTC FOR 98024 N GOOD LOW NO CHANGE

PLAS-W 0 N/A 640 SF 98051-X PLAS N GOOD MOD NO CHANGE

BSBRD 0 N/A N/A 98052-X 4" TAN BSBRD N GOOD LOW NO CHANGE

MSTC 0 N/A N/A…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .