This document is a Request for Proposal (RFP) issued by the Department of Energy Ames Laboratory for an Access Controls Upgrade project. The RFP seeks to acquire goods and services as described in the attached Appendix B - Project Specifications and Drawings, dated 11/08/2024, to support the Ames Laboratory facility located in Ames, Iowa. The Laboratory intends to award one subcontract resulting from this solicitation to the offeror whose proposal will be most advantageous, considering best value, price, and other factors. The solicitation number is RFP-SC-25-653.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GENERAL NOTES:

A. SCREENED (GRAY-TONE) LINES INDICATE EXISTING

CONSTRUCTION TO REMAIN.

B. BOLD DASHED LINES INDICATE EXISTING

CONSTRUCTION TO BE REMOVED.

C. FIELD VERIFY EXISTING BUILDING CONDITIONS,

ELEVATIONS, AND DIMENSIONS PRIOR TO START

OF WORK. NOTIFY ARCHITECT OF ANY

DISCREPANCIES FOUND IN RELATION TO THE

CONTRACT DOCUMENTS.

D. GENERAL CONTRACTOR SHALL COORDINATE

WORK OF ALL TRADES PRIOR TO STARTING ANY

DEMOLITION/CONSTRUCTION.

E. DO NOT SCALE DRAWINGS TO DETERMINE

DIMENSIONS. VERIFY ALL DIMENSIONS AND

IMMEDIATELY REPORT ANY DISCREPANCIES TO

THE ARCHITECT.

F. PERFORM DEMOLITION WITHOUT DAMAGE TO

ADJACENT RETAINED CONSTRUCTION. WHERE

SUCH DAMAGE OCCURS, PATCH, REPAIR, OR

OTHERWISE RESTORE TO ITS ORIGINAL

CONDITION.

G. PATCH AND REPAIR ALL OPENINGS AND VOIDS

LEFT BY REMOVAL OF EXISTING CONSTRUCTION,

EQUIPMENT, PIPING, DUCTS, CONDUIT, ETC. AS

REQUIRED TO MATCH ADJACENT, SEE SPEC 01 73

29 CUTTING AND PATCHING.

H. PROTECT FROM DAMAGE ALL EXISTING

CONSTRUCTION TO REMAIN.

I. MAINTAIN THE BUILDING IN A WEATHER TIGHT

CONDITION AT ALL TIMES.

J. MAINTAIN OPERATION OF ALL EXISTING SERVICES

AND UTILITIES TO THE BUILDING. COORDINATE ANY

DISRUPTIONS OR DISCONTINUATIONS WITH THE

OWNER'S REPRESENTATIVE IN ADVANCE.

K. PROVIDE ALL DEMOLITION AND DISPOSAL AS

REQUIRED FOR INSTALLATION OF NEW WORK AS

INDICATED, OR AS REASONBLY IMPLIED BY THESE

CONSTRUCTION DOCUMENTS.

L. STORE AND PROTECT ALL SALVAGED ITEMS

NOTED OR REQUESTED TO BE RETURNED TO

OWNER. COORDINATE WITH OWNER FOR THE

LOCATION OF STORAGE FOR SALVAGED ITEMS.

SHEET NUMBER

SHEET TITLE

REVISION DATE

CONSULTANT

LOCATION

PHONE

WEBSITE

219 EIGHTH STREET

DES MOINES, IOWA 50309

515-244-7167

WWW.BBSAE.COM

ISSUE DATE

PROJECT NUMBER

SUBMISSION

/8

/4

/2

/4

A

/2

30x42 9 10

/1

B

C

D

E

F

G

H

87654321

9 1087654321

/7

/2

:3

:3

P

M

C

U s e rs

\M G a u l\ D o c u m e n ts

\R e v it

L o c a l F ile s \2

M e ta ls D e v e lo p m e n t A

R C

H m a tt h e w g a u l.

rv t

ISSUE FOR BID

M E

T A

L S

D E

V E

L O

P M

E N

T

A M

E S

IA

DOOR

CONTROLLER

PANEL

SCHEDULE

AND GENERAL

NOTES

P

A M

M E

L D

R

IV

E

A M

E S

N A

T

IO

N A

L L

A B

O R

A T

O R

Y

U P

G R

A D

E A

C C

E S

S C

O N

T R

O L

S Y

S T

E M

G-001

22027

11/08/2024 ----- - INDICATES SPACE NOT AVAILABLE DUE TO HARDWIRED LOCKSETS ON SAME CONTROLLER.

HW - INDICATES HARD-WIRED LOCKSETS.

Star016W-64ANPS 8 DOOR

SIF SIF#1 SIF 117

iSTAR Classic/Pro REPLACE WITH ULTRA G2 HW 1 100 101 103 104 110 111 130

PAC #2

PAC #1

formerly ESTAR002 (X2)

PAC

PAC PAC 106 iSTAR Edge REPLACE WITH EDGE G2 HW 1 D101 D102 D103

MMB#3

MMB#2

MMB#1

formerly ESTAR002 (X3)

MMB

MMB MMB 101 iSTAR Edge REPLACE WITH EDGE G2 HW 1 D101 D102 D104 D105

MSB#2

MSB#1

formerly ESTAR002 (X2)

MSB

MSB

MSB 102

(MEZZ)

iSTAR Edge REPLACE WITH EDGE G2 HW 1 D101 D102 D104

CWH#2

CWH#1

formerly ESTAR002 (X2)

CWH

CWH #1

CWH 102

iSTAR Edge REPLACE WITH EDGE G2 HW 1 D101 D103 D107 D110

ESTAR002

RS Records Storage MAIN iSTAR Edge REPLACE WITH EDGE G2 HW 1 D101 D102

Star016W-64ANPS 2 331 335 335A 336 401A 402

HWH HWH 3RD FLR #2 CORR

iSTAR Classic/Pro

NO CHANGE

HW 1 303 306 307 312 320 321 322 330

Star016W-64ANPS 2 316 317 324 326 327 329 332 334

HWH HWH 3RD FLR #1 CORR

iSTAR Classic/Pro

NO CHANGE

HW 1 302 304 305 308 310 311 314 315

Star016W-64ANPS 2 224 227 230

HWH HWH 2ND FLR #2 CORR

iSTAR Classic/Pro

NO CHANGE

HW 1 204 204A 206 216A 216B 220 221 222

Star016W-64ANPS 2 225 228 231 232 234 235 236 237

HWH HWH 2ND FLR #1 CORR

iSTAR Classic/Pro

NO CHANGE

HW 1 203 205 209 210 213 214 216 217

Star016W-64ANPS 16 DOOR 2 D102 D104 D106

HWH HWH 1ST FLR #2 CORR

iSTAR Classic/Pro REPLACE WITH ULTRA G2 HW 1 101 107 111 115 121 134 138 D101

Star016W-64ANPS 2 117 118 122 125 129 137

HWH HWH 1ST FLR #1 CORR

iSTAR Classic/Pro

NO CHANGE

HW 1 102 103 104 105 106 110 112 116

Star016W-64ANPS 2 33 34 41 47 48 49 50

HWH HWH GRND #2 CORR

iSTAR Classic/Pro

NO CHANGE

HW 1 16 24 25 28 29 31 31A 32

Star016W-64ANPS 2 36 37 38 39 40 44 45 46

HWH HWH GRND #1 CORR

iSTAR Classic/Pro

NO CHANGE

HW 1 11 13 15 18 20 22 26 30

Star016W-64ANPS 16 DOOR 2 335-2 351 C330

TASF TASF 3RD FLR TASF 304

iSTAR Classic/Pro REPLACE WITH ULTRA G2 HW 1 304 305-1 311 329 332 331-1 334 336-1

Star016W-64ANPS 16 DOOR 2 C230

TASF TASF 2ND FLR TASF 204

iSTAR Classic/Pro REPLACE WITH ULTRA G2 HW 1 204 205 211 224A 225 231 252 254

Star016W-64ANPS 16 DOOR 2 C111 C118 C130 105C 105D

TASF TASF 1ST FLR TASF 104

iSTAR Classic/Pro REPLACE WITH ULTRA G2 HW 1 104 105B 132 112-1 151A-1 140 140-1 C110A

ESTAR002

TASF TASF GRND FLR #2 TASF G04

iSTAR Edge

NO CHANGE

HW G57

Star016W-64ANPS 16 DOOR 2 G34 G35-1 G40-1 G49

TASF TASF GRND FLR #1 TASF G04

iSTAR Classic/Pro REPLACE WITH ULTRA G2 HW 1 B03 B04 CB01 CG10A CG31-2 G04 G11 G22

1 2 3 4 5 6 7 8 Building Panel Name Room Existing Configuration New Configuration

PIM-400

Group

Board Controlled Doors

4 321 322 323 324 325 326

B 3 314A 314 315 316 317 318 319 320

32 door 2 332 361

SPH SPH 3RD #2 SPH 361 N/A

ADD ULTRA G2 A 1 307 308 309 314B 303 328 329 330

4 336

B 3 349 348 347 346 343 342 340 339

SPH 3rd FLR #1 2 ----- ----- ----- ----- ----- ----- ----- -----formerly Star016W-64ANPS 32 door A 1 357 356 355 354 353 352

SPH

SPH 3rd #1

SPH 361

iSTAR Classic/Pro REPLACE WITH ULTRA G2 HW 1 C34 301AB 301CB 301DA 301E C36

4 239 238 237 236 245

B 3 249 248 247 246 244 C26A 241 240

32 door 2 232 233 234 235 261

SPH SPH 2ND #2 SPH 261 N/A

ADD ULTRA G2 A 1 258 259 260 C22 255 254 253 252

4 228 229 230 231

B 3 201B 207 208 209 203 211A 201A 227

32 door 2 223 224 225 226

SPH SPH 2ND #1 SPH 261 N/A

ADD ULTRA G2 A 1 213 214 216 217 219 220 221 222

4 138C 138D 136B

SPH 1ST FLR #2-B B 3 148A C13 148B 144A 144B 142 138B 138A

formerly Star016W-64ANPS 32 door 2 132C

SPH

SPH 1ST #3

SPH 100

iSTAR Classic/Pro REPLACE WITH ULTRA G2 A 1 100 C63 153 152 151 136C 132A 132B

4 105 107 108 109

SPH 1ST FLR #1-B B 3 124A 122A 118 116 114 103 105B 105A

formerly Star016W-64ANPS 32 door 2 127 128A 129 130 160

SPH

SPH 1ST #2

SPH 100

iSTAR Classic/Pro REPLACE WITH ULTRA G2 HW 1 113 115 117 119 120 122B 124B 125

SPH 1ST FLR #2

SPH 1ST FLR #1

SPH GRND FLR #1

formerly ESTAR002 (x3)

SPH

SPH GND/1ST #1

SPH100

iSTAR Edge ADD EDGE G2 1 DG01 D101 D102 D103

4 042A 43 44 45 46 47

B 3 034B 35 36 37 38 39 40 041A

32 door 2 30 32 33B ----- -----

Star016W-64ANPS REPLACE WITH ULTRA G2 A 1 61 15 CG3A 24 25 26 27 28

SPH

SPH GRND #1

formerly

SPH GRND-#1B

SPH 32A

iSTAR Classic/Pro HW 1 2 ----- ----- ----- ----- ----- -----

4 8 7 6 5 4

B 3 B56 B56A 54 53 52 51 10 9

Star016W-64ANPS 32 door 2

SPH SPH BSMT #2 SPH B1

iSTAR Classic/Pro REPLACE WITH ULTRA G2 HW 1 B43 B51 B52B B53 B54 B55 B57 B56B

4 B40A B44 B45 B46 B47

B 3 B1 B31 B33 B34 B35 B36 B37 B39

32 door 2 B19 B20 B22 B25 B27 B28

SPH SPH BSMT #1 SPH B1 N/A

ADD ULTRA G2 A 1 B4 B5 B8A B9 B10 B11 B15 B17

4 296A

B 3 206 207 208 209 210 211 C27 297

32 door 2 230 204 205

MD DEV #5 MD 244 N/A

ADD ULTRA G2 A 1 220 221 222A 223 224 225A 227A 228

HW 3 244A

32 door 2 296B 240

MD DEV #4 MD 244 N/A

ADD ULTRA G2 A 1 293 292 244C 291B 291 294 295B 295C

4 198B 192A 199A

B 3 114A 105 106 107 108A 109 110 111

32 door 2 190B C28 S25

MD DEV #3 MD 157 N/A

ADD ULTRA G2 A 1 164 180 167 162 160 192 190A 189

4 120 135B

B 3 141 139 126 125A 124A 123 122 121

32 door 2 B3

MD DEV #2 MD 157 N/A

ADD ULTRA G2 A 1 177 187A 187B 135A 146 142 150 B1

B 3 159 157 C19C C26 257A 258M

Existing 16 door upgrade to 32 door 2 160A S17B C17B S27

MD DEV #1 MD 157

Istar G2 Ultra GCM BD Istar G2 Ultra GCM BD HW 1 147 258 D101 D102 D103 D105 D106 D110

1 2 3 4 5 6 7 8 Building Panel Name Room Existing Configuration New Configuration

PIM-400

Group

Board Controlled Doors

DOOR CONTROLLER PANEL SCHEDULE

B1

B2

B5

B4

B3

B

B

B

B1

2347891

TUNNEL TO

SPEDDING

HALL

DEV #2-A

OWNER'S EXISTING

DATA PATCH PANEL

121314151718192016212223

1022. .

SHEET NUMBER

SHEET TITLE

REVISION DATE

CONSULTANT

LOCATION

PHONE

WEBSITE

219 EIGHTH STREET

DES MOINES, IOWA 50309

515-244-7167

WWW.BBSAE.COM

ISSUE DATE

PROJECT NUMBER

SUBMISSION

/8

/4

/2

/4

A

/2

30x42 9 10

/1

B

C

D

E

F

G

H

87654321

9 1087654321

/7

/2

:3

:3

P

M

C

U s e rs

\M G a u l\ D o c u m e n ts

\R e v it

L o c a l F ile s \2

M e ta ls D e v e lo p m e n t A

R C

H m a tt h e w g a u l.

rv t

ISSUE FOR BID

M E

T A

L S

D E

V E

L O

P M

E N

T

A M

E S

IA

BASEMENT

LEVEL - FLOOR

PLAN

P

A M

M E

L D

R

IV

E

A M

E S

N A

T

IO

N A

L L

A B

O R

A T

O R

Y

U P

G R

A D

E A

C C

E S

S C

O N

T R

O L

S Y

S T

E M

MD-E-100

22027

11/08/2024

1/8" = 1'-0"A1 BASEMENT LEVEL - FLOOR PLAN

KEYNOTE LEGEND

1 REPLACE EXISTING CARD READER WITH NEW CARD

READER.

2 REPLACE EXISTING ISTAR PRO CONTROLLER WITH

NEW ISTAR ULTRA G2 CONTROLLER.

3 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR ULTRA G2 CONTROLLER.

4 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR EDGE G2 CONTROLLER.

5 ADD NEW ISTAR ULTRA G2 CONTROLLER.

6 UPGRADE EXISTING ISTAR ULTRA G2 CONTROLLER

TO 32 DOORS.

7 NEW WIRELESS LOCKSET.

8 EXISTING WIRED CONTROL TO REMAIN.

9 EXISTING MONITORED DOOR TO REMAIN.

10 NOT USED.

11 NEW HARDWIRED CARD READER, DOOR POSITION

SWITCH, AND MAG LOCK. ROUTE WIRING TO DOOR

CONTROLLER LOCATION AS INDICATED. PATHWAY

BY OWNER, WIRING BY CONTRACTOR.

12 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM B3. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

13 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM 029. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

14 CONTRACTOR TO VERIFY CABLING

DESTINATIONS/UTILIZATION PRIOR TO DEMOLITION.

15 REVISE CABLING/DOOR CONTROL TO ENABLE

MOTORIZED DOOR OPERATOR SWITCH UPON

SUCCESSFUL CARD READ OPERATION.

16 DOOR, FRAME, AND WALL PREPPED FOR FUTURE

DOOR CONTROL.

17 DOOR LOCATION FORMERLY CONTROLLED BY

ACCESS CONTROL SYSTEM.

18 ALTERNATE 1: ADD INTERIOR SUITE DOOR CONTROL.

19 ALTERNATE 2: ADD SECONDARY ENTRY DOOR

CONTROL.

20 ALTERNATE 3: ADD DOOR CONTROL FOR

MECHANICAL, ELECTRICAL, AND CUSTODIAL SPACES.

21 EXISTING WIRELESS LOCKSET

22 NOT USED.

23 MOUNT PIM-400 TRANSCEIVER NEAR LOCATION

SHOWN. IF THE ROOM INDICATED HAS A LAY-IN

CEILING, MOUNT UNIT IN AN ACCESSIBLE LOCATION

ABOVE THE CEILING. IF THE ROOM DOES NOT HAVE

AN ACCESSIBLE LOCATION, LOCATE THE UNIT AS

HIGH AS PRACTICAL IN THE SPACE, BUT MINIMUM 6”

BELOW THE INACCESSIBLE CEILING.

DOOR SCHEDULE - BASEMENT

DOOR NO.

DOOR

KEYNOTE

WIDTH x HEIGHT

WIDTH HEIGHT

B1 6' - 0" 7' - 4" 7, 20

B3 6' - 0" 7' - 4" 7, 20

CR

J

C R

C R

C R

C R

CR

J

J

J

CR

CR

J

J J

111B

111A

S13

111C

109 108 107 106 105 104

C11

128 126 125 124 123 122 121 120

190192

114 140

S14

S18

167A

167B167C

167D

S15

C15

164 163 162 162A 161

C17

C19

158B 158C 158D 158E 158F 158G 158H 158I

158J158L158M158N 158K

S17

C14

150 150

150C

150B

150A

155154

C B

D

160A

D103

C B

135AS14

150AB

D107

D108

131A

D109

B

A

190B

A

131BC

C

C B

D

C

B

D

A

A

125B 124B

C

A

B

S13B

A

108B

C

A

111B

111CB

111A

D102

S

C19C

N

B

C

M

D

E

F

G

H

I

158J

A

B C

B

187A

187B

S17B

B

C18

C16

C13 C12

S16

S12

S12B D110

-1

D106

A

PIM-400

x4

A

PIM-400 PIM-400

PIM-400

A

A

PIM-400

AA

7777777

77777 7 7

1 11

A

160A

DEV #1-B

DEV #1

DEV #2

DEV #3

DEV #3-A

DEV #2-A

DEV #2-BDEV #3-B

DP

ML

DP

ML

PATHWAY TO

SECOND FLOOR

7 18

7 18

23 23

SHEET NUMBER

SHEET TITLE

REVISION DATE

CONSULTANT

LOCATION

PHONE

WEBSITE

219 EIGHTH STREET

DES MOINES, IOWA 50309

515-244-7167

WWW.BBSAE.COM

ISSUE DATE

PROJECT NUMBER

SUBMISSION

/8

/4

/2

/4

A

/2

30x42 9 10

/1

B

C

D

E

F

G

H

87654321

9 1087654321

/7

/2

:3

:4

P

M

C

U s e rs

\M G a u l\ D o c u m e n ts

\R e v it

L o c a l F ile s \2

M e ta ls D e v e lo p m e n t A

R C

H m a tt h e w g a u l.

rv t

ISSUE FOR BID

M E

T A

L S

D E

V E

L O

P M

E N

T

A M

E S

IA

LEVEL 1 -

FLOOR PLAN

P

A M

M E

L D

R

IV

E

A M

E S

N A

T

IO

N A

L L

A B

O R

A T

O R

Y

U P

G R

A D

E A

C C

E S

S C

O N

T R

O L

S Y

S T

E M

MD-E-101

22027

11/08/2024

1/8" = 1'-0"A1 LEVEL 1 - FLOOR PLAN

DOOR SCHEDULE - LEVEL 1

DOOR NO.

DOOR

KEY

NOTES

WIDTH x HEIGHT

WIDTH HEIGHT

105 3' - 0" 7' - 0" 7

106 3' - 0" 7' - 0" 7

107 3' - 0" 7' - 0" 7

108A 3' - 0" 7' - 0" 7

109 3' - 0" 7' - 0" 7

110 3' - 0" 7' - 0" 7

111 3' - 0" 7' - 0" 7

114A 2' - 6" 6' - 8" 7

120 3' - 0" 7' - 0" 7

121 3' - 0" 7' - 0" 7

122 3' - 0" 7' - 0" 7

123 3' - 0" 7' - 0" 7

124A 3' - 0" 7' - 0" 7

125A 3' - 0" 7' - 0" 7

126 3' - 0" 7' - 0" 7

135A 5' - 0" 6' - 0" 7

135B 5' - 0" 6' - 0" 7

139 2' - 6" 6' - 8" 7, 20

141 2' - 6" 6' - 8" 7, 20

142 3' - 0" 7' - 0" 7

146 5' - 0" 6' - 0" 7

147 5' - 0" 6' - 0" 8

150 5' - 0" 6' - 0" 7

157 5' - 0" 6' - 0" 7, 20

159 6' - 0" 7' - 4" 21

160 6' - 4" 7' - 4" 7, 18

160A 6' - 4" 7' - 4" 8

162 6' - 0" 7' - 4" 7

164 3' - 0" 7' - 0" 7

167 3' - 0" 7' - 0" 7

177 5' - 0" 6' - 0" 7

180 3' - 0" 7' - 0" 7

187A 5' - 0" 6' - 0" 7, 19

187B 5' - 0" 6' - 0" 7

189 3' - 0" 7' - 0" 7

190A 5' - 0" 6' - 0" 7

190B 5' - 0" 6' - 0" 7

192 5' - 0" 6' - 0" 7, 18

192A 2' - 10" 6' - 8" 7, 18

199A 5' - 0" 6' - 0" 7, 18

199B 2' - 10" 6' - 8" 7

C17B 3' - 0" 7' - 0" 11

C19C 3' - 0" 7' - 0" 7

D101 6' - 0" 7' - 4" 1

D102 3' - 0" 7' - 0" 1

D103 3' - 0" 7' - 0" 1

D105 6' - 4" 7' - 4" 1

D106 3' - 0" 7' - 0" 1

D107 5' - 0" 6' - 0" 9

D108 5' - 0" 6' - 0" 9

D109 5' - 0" 6' - 0" 9

D110 3' - 0" 7' - 0" 1

S17B 3' - 0" 7' - 0" 11

KEYNOTE LEGEND

1 REPLACE EXISTING CARD READER WITH NEW CARD

READER.

2 REPLACE EXISTING ISTAR PRO CONTROLLER WITH

NEW ISTAR ULTRA G2 CONTROLLER.

3 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR ULTRA G2 CONTROLLER.

4 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR EDGE G2 CONTROLLER.

5 ADD NEW ISTAR ULTRA G2 CONTROLLER.

6 UPGRADE EXISTING ISTAR ULTRA G2 CONTROLLER

TO 32 DOORS.

7 NEW WIRELESS LOCKSET.

8 EXISTING WIRED CONTROL TO REMAIN.

9 EXISTING MONITORED DOOR TO REMAIN.

10 NOT USED.

11 NEW HARDWIRED CARD READER, DOOR POSITION

SWITCH, AND MAG LOCK. ROUTE WIRING TO DOOR

CONTROLLER LOCATION AS INDICATED. PATHWAY

BY OWNER, WIRING BY CONTRACTOR.

12 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM B3. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

13 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM 029. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

14 CONTRACTOR TO VERIFY CABLING

DESTINATIONS/UTILIZATION PRIOR TO DEMOLITION.

15 REVISE CABLING/DOOR CONTROL TO ENABLE

MOTORIZED DOOR OPERATOR SWITCH UPON

SUCCESSFUL CARD READ OPERATION.

16 DOOR, FRAME, AND WALL PREPPED FOR FUTURE

DOOR CONTROL.

17 DOOR LOCATION FORMERLY CONTROLLED BY

ACCESS CONTROL SYSTEM.

18 ALTERNATE 1: ADD INTERIOR SUITE DOOR CONTROL.

19 ALTERNATE 2: ADD SECONDARY ENTRY DOOR

CONTROL.

20 ALTERNATE 3: ADD DOOR CONTROL FOR

MECHANICAL, ELECTRICAL, AND CUSTODIAL SPACES.

21 EXISTING WIRELESS LOCKSET

22 NOT USED.

23 MOUNT PIM-400 TRANSCEIVER NEAR LOCATION

SHOWN. IF THE ROOM INDICATED HAS A LAY-IN

CEILING, MOUNT UNIT IN AN ACCESSIBLE LOCATION

ABOVE THE CEILING. IF THE ROOM DOES NOT HAVE

AN ACCESSIBLE LOCATION, LOCATE THE UNIT AS

HIGH AS PRACTICAL IN THE SPACE, BUT MINIMUM 6”

BELOW THE INACCESSIBLE CEILING.

J

J

CR

J J

S27C29

258N 258M

258L 258K

S21

228A 224A

225227

223 222

S22

S23

204211A 211 210 208 207 205206

241A

241B

284283

289 287

S24

C26

295295A

C23

294 291

C27

293 292

293A

258P

258A 258I258H258G258F258E

B

A

B

A

C28A

A

C

C A

A

296B

S24

257B

257A

257B

A

E

C29A

F

N

G

M

L

K

C B

S27

I

H

241B

241A2

274 279

293A

B

244C

244B

S23

A

A

A

A

222B

225B

A

A

227B

224AB

295B

295A

C28

S25

241C

C24

C25

C21

S26

257B 257C 258B 258C 258D

258O258Q

S22

211A

C

284A

203 230

A

PIM-400

x2 5

PIM-400

A

S24A

PIM-400

A

77 777

VERIFY DOOR

SWING

S257

C

C

7 7

VERIFY DOOR

SWING

DEV #3-A

DEV #1-B

DEV #5

DEV #4

DEV #4-A

DEV #5-B DEV #5-A

DP

ML

PAHTWAY CONDUIT ROUTED

THRU CLOSET TO AREA

ABOVE FIRST FLOOR CEILING,

THEN TO DOOR CONTROLLER

DEV#1 IN ROOM 157.

DP

ML

7 20

7 18

7 19

23 23

C22

SHEET NUMBER

SHEET TITLE

REVISION DATE

CONSULTANT

LOCATION

PHONE

WEBSITE

219 EIGHTH STREET

DES MOINES, IOWA 50309

515-244-7167

WWW.BBSAE.COM

ISSUE DATE

PROJECT NUMBER

SUBMISSION

/8

/4

/2

/4

A

/2

30x42 9 10

/1

B

C

D

E

F

G

H

87654321

9 1087654321

/7

/2

:3

:2

P

M

C

U s e rs

\M G a u l\ D o c u m e n ts

\R e v it

L o c a l F ile s \2

M e ta ls D e v e lo p m e n t A

R C

H m a tt h e w g a u l.

rv t

ISSUE FOR BID

M E

T A

L S

D E

V E

L O

P M

E N

T

A M

E S

IA

LEVEL 2 -

FLOOR PLAN

P

A M

M E

L D

R

IV

E

A M

E S

N A

T

IO

N A

L L

A B

O R

A T

O R

Y

U P

G R

A D

E A

C C

E S

S C

O N

T R

O L

S Y

S T

E M

MD-E-102

22027

11/08/2024

1/8" = 1'-0"A1 LEVEL 2 - FLOOR PLAN

KEYNOTE LEGEND

1 REPLACE EXISTING CARD READER WITH NEW CARD

READER.

2 REPLACE EXISTING ISTAR PRO CONTROLLER WITH

NEW ISTAR ULTRA G2 CONTROLLER.

3 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR ULTRA G2 CONTROLLER.

4 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR EDGE G2 CONTROLLER.

5 ADD NEW ISTAR ULTRA G2 CONTROLLER.

6 UPGRADE EXISTING ISTAR ULTRA G2 CONTROLLER

TO 32 DOORS.

7 NEW WIRELESS LOCKSET.

8 EXISTING WIRED CONTROL TO REMAIN.

9 EXISTING MONITORED DOOR TO REMAIN.

10 NOT USED.

11 NEW HARDWIRED CARD READER, DOOR POSITION

SWITCH, AND MAG LOCK. ROUTE WIRING TO DOOR

CONTROLLER LOCATION AS INDICATED. PATHWAY

BY OWNER, WIRING BY CONTRACTOR.

12 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM B3. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

13 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM 029. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

14 CONTRACTOR TO VERIFY CABLING

DESTINATIONS/UTILIZATION PRIOR TO DEMOLITION.

15 REVISE CABLING/DOOR CONTROL TO ENABLE

MOTORIZED DOOR OPERATOR SWITCH UPON

SUCCESSFUL CARD READ OPERATION.

16 DOOR, FRAME, AND WALL PREPPED FOR FUTURE

DOOR CONTROL.

17 DOOR LOCATION FORMERLY CONTROLLED BY

ACCESS CONTROL SYSTEM.

18 ALTERNATE 1: ADD INTERIOR SUITE DOOR CONTROL.

19 ALTERNATE 2: ADD SECONDARY ENTRY DOOR

CONTROL.

20 ALTERNATE 3: ADD DOOR CONTROL FOR

MECHANICAL, ELECTRICAL, AND CUSTODIAL SPACES.

21 EXISTING WIRELESS LOCKSET

22 NOT USED.

23 MOUNT PIM-400 TRANSCEIVER NEAR LOCATION

SHOWN. IF THE ROOM INDICATED HAS A LAY-IN

CEILING, MOUNT UNIT IN AN ACCESSIBLE LOCATION

ABOVE THE CEILING. IF THE ROOM DOES NOT HAVE

AN ACCESSIBLE LOCATION, LOCATE THE UNIT AS

HIGH AS PRACTICAL IN THE SPACE, BUT MINIMUM 6”

BELOW THE INACCESSIBLE CEILING.

DOOR SCHEDULE - LEVEL 2

DOOR NO.

DOOR

KEY

NOTES

WIDTH x HEIGHT

WIDTH HEIGHT

204 2' - 10" 7' - 0" 7

205 2' - 10" 7' - 0" 7

206 2' - 10" 7' - 0" 7

207 2' - 10" 7' - 0" 7

208 2' - 10" 7' - 0" 7

209 2' - 10" 7' - 0" 7

210 2' - 10" 7' - 0" 7, 19

211 2' - 10" 7' - 0" 7

220 2' - 10" 6' - 8" 7

221 2' - 10" 6' - 8" 7

222A 2' - 10" 6' - 8" 7

223 2' - 10" 6' - 8" 7

224 2' - 10" 6' - 8" 7

225A 2' - 10" 6' - 8" 7

227A 2' - 10" 6' - 8" 7

228 2' - 10" 6' - 8" 7

230 2' - 10" 6' - 8" 7

240 6' - 0" 7' - 4" 7, 20

244A 6' - 0" 7' - 4" 11

244C 6' - 4" 7' - 4" 7, 20

257A 3' - 0" 6' - 8" 7

258 6' - 4" 7' - 4" 8

258M 3' - 0" 6' - 8" 7

291 2' - 10" 6' - 8" 7

291B 2' - 10" 6' - 8" 7, 19

292 6' - 0" 7' - 4" 7

293 6' - 0" 7' - 4" 7

294 5' - 0" 6' - 0" 7

295B 5' - 0" 6' - 0" 7

295C 3' - 0" 7' - 0" 7, 18

296A 3' - 0" 7' - 0" 7

296B 6' - 0" 7' - 4" 7, 19

297 6' - 0" 7' - 4" 7

C26 2' - 6" 6' - 8" 7

C27 2' - 10" 6' - 8" 7

C28 2' - 10" 6' - 8" 7

S25 2' - 10" 6' - 8" 7

S27 3' - 0" 6' - 8" 11

UP

J J

J

B19 B17

B15

B15A

B11

B10

B20 B22 B27 B28B25 B31

B31A

B33 B34 B35 B36 B37 B39A B39 B40CB5

B43

B44B45B46

B47B52

B51

B47A

B53

SB2

B54B55

B57

B56B

B56A

B56

B54A

CB2

B4

B3 B2

JAN

CB4

CG3

ELEV

SB1

B1

B5B

B5 B5C

B7

B7A

B8

B9

CB1

B 9 B

B

C G

B

B A

B11

B10

B5B8A

B4

B A

B

B

B

B

B

B

B A

B39A

B40B

B43

B

B

B

B52A B51

B52B

B56B

B31B

B C

B5B8B

B9

SB1 SB2

B

B

B

B

B

B

B53

B57

B54

B56A

B47B

B

B

B

B

B

B

B55

C73

A

A

PIM-400

PIM-400

A

SPH BSMT #1

7 7 7

7 7 7

12345789

SPH BSMT #2

1011121314151617181920

SPH BSMT #2-B

PIM-400

MOUNT ANTENNA HIGH

IN TWO-STORY SPACE

TO ENSURE COVERAGE

FOR GROUND FLOOR

LOCKSETS.

SPH BSMT #1-B

SPH BSMT #1-A

7 20

197 197

231022. .

SHEET NUMBER

SHEET TITLE

REVISION DATE

CONSULTANT

LOCATION

PHONE

WEBSITE

219 EIGHTH STREET

DES MOINES, IOWA 50309

515-244-7167

WWW.BBSAE.COM

ISSUE DATE

PROJECT NUMBER

SUBMISSION

/8

/4

/2

/4

A

/2

30x42 9 10

/1

B

C

D

E

F

G

H

87654321

9 1087654321

/7

/2

:5

:2

P

M

C

U s e rs

\M G a u l\ D o c u m e n ts

\R e v it

L o c a l F ile s \2

S p e d d in g A

R C

H m a tt h e w g a u l.

rv t

ISSUE FOR BID

S P

E D

D

IN

G H

A L

L

A M

E S

IA

BASEMENT

LEVEL - FLOOR

PLAN

P

A M

M E

L D

R

IV

E

A M

E S

N A

T

IO

N A

L L

A B

O R

A T

O R

Y

U P

G R

A D

E A

C C

E S

S C

O N

T R

O L

S Y

S T

E M

SPH-E-000

22027

11/08/2024

1/8" = 1'-0"A1 BASEMENT LEVEL - FLOOR PLAN

DOOR SCHEDULE - BASEMENT

DOOR NO.

DOOR

KEY

NOTES

WIDTH x HEIGHT

WIDTH HEIGHT

B1 6' - 0" 7' - 4" 7, 20

B4 3' - 0" 7' - 0" 7

B5 3' - 0" 7' - 0" 7

B8A 3' - 0" 7' - 0" 7

B9 5' - 0" 7' - 4" 7, 19

B10 3' - 0" 7' - 0" 7

B11 3' - 0" 7' - 0" 7

B15 6' - 0" 7' - 4" 7

B17 6' - 0" 7' - 4" 7, 19

B19 3' - 0" 7' - 0" 7, 20

B20 5' - 0" 7' - 4" 7

B22 6' - 0" 7' - 4" 7

B25 6' - 0" 7' - 4" 7

B27 3' - 0" 7' - 0" 7

B28 5' - 0" 7' - 4" 7

B31 6' - 0" 7' - 4" 7, 20

B33 3' - 0" 7' - 0" 7

B34 3' - 0" 7' - 0" 7, 19

B35 3' - 0" 7' - 0" 7

B36 3' - 0" 7' - 0" 7

B37 3' - 0" 7' - 0" 7, 19

B39 3' - 0" 7' - 0" 7

B40A 3' - 0" 7' - 0" 7

B43 3' - 0" 7' - 0" 8

B44 6' - 0" 7' - 4" 7

B45 3' - 0" 7' - 0" 7

B46 3' - 0" 7' - 0" 7

B47 6' - 0" 7' - 4" 7, 20

B51 3' - 0" 6' - 8" 8

B52B 3' - 0" 7' - 0" 8

B53 3' - 0" 7' - 0" 8

B54 6' - 0" 7' - 4" 8

B55 3' - 0" 7' - 0" 8

B56B 3' - 0" 7' - 0" 8

B57 3' - 0" 7' - 0" 8

KEYNOTE LEGEND

1 REPLACE EXISTING CARD READER WITH NEW CARD

READER.

2 REPLACE EXISTING ISTAR PRO CONTROLLER WITH

NEW ISTAR ULTRA G2 CONTROLLER.

3 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR ULTRA G2 CONTROLLER.

4 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR EDGE G2 CONTROLLER.

5 ADD NEW ISTAR ULTRA G2 CONTROLLER.

6 UPGRADE EXISTING ISTAR ULTRA G2 CONTROLLER

TO 32 DOORS.

7 NEW WIRELESS LOCKSET.

8 EXISTING WIRED CONTROL TO REMAIN.

9 EXISTING MONITORED DOOR TO REMAIN.

10 NOT USED.

11 NEW HARDWIRED CARD READER, DOOR POSITION

SWITCH, AND MAG LOCK. ROUTE WIRING TO DOOR

CONTROLLER LOCATION AS INDICATED. PATHWAY

BY OWNER, WIRING BY CONTRACTOR.

12 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM B3. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

13 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM 029. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

14 CONTRACTOR TO VERIFY CABLING

DESTINATIONS/UTILIZATION PRIOR TO DEMOLITION.

15 REVISE CABLING/DOOR CONTROL TO ENABLE

MOTORIZED DOOR OPERATOR SWITCH UPON

SUCCESSFUL CARD READ OPERATION.

16 DOOR, FRAME, AND WALL PREPPED FOR FUTURE

DOOR CONTROL.

17 DOOR LOCATION FORMERLY CONTROLLED BY

ACCESS CONTROL SYSTEM.

18 ALTERNATE 1: ADD INTERIOR SUITE DOOR CONTROL.

19 ALTERNATE 2: ADD SECONDARY ENTRY DOOR

CONTROL.

20 ALTERNATE 3: ADD DOOR CONTROL FOR

MECHANICAL, ELECTRICAL, AND CUSTODIAL SPACES.

21 EXISTING WIRELESS LOCKSET

22 NOT USED.

23 MOUNT PIM-400 TRANSCEIVER NEAR LOCATION

SHOWN. IF THE ROOM INDICATED HAS A LAY-IN

CEILING, MOUNT UNIT IN AN ACCESSIBLE LOCATION

ABOVE THE CEILING. IF THE ROOM DOES NOT HAVE

AN ACCESSIBLE LOCATION, LOCATE THE UNIT AS

UP UP UP

CR

C R

J

J J

B

A

SG2

055A 053

DG01

SG1A

CG3A

B

B

B

B

A

A

041B

CG01-1

G

G18

G

G15

G13

G

G25

C24

G23 G21

G

C G

A

G

CG32C

G

G

G

G46

G47

G48

G

G A

G40-1

G41

G35-1

G

G22B

G22A

G58 G56A

G56B

CG50CG10A CG10AB

CG31C

C G

G16

G15

G29

G28

C24

G26

G43

G58

G53

G20

G57

G40C

CG32A

CG32C

G35

G34

G34A

G40B

G40

CG03

G22

G11

G12G14A

G14

G17A

CG02

CG10

CG10A

G19 G21 G23

G42 G44

G46

G45

G18

CG30

G25

G41CG32B

G47

G48

G33

CG50

G40A G49 G13

CG70

G71 G56G04

CG31

G56A

G52

G51

G27

G17

CG57

CG01A

CG1

SG1

002 ELEV 061

055 053

CG2

SG2

047 046 045 044

042041040039038036034 037035033032032A031

032B

029028027026025024023022021020

019 018 017 015016

CG3A

CG4

B106

CG5

CG5A

CG5B

A

PIM-400

SPH GRND #1

A

PIM-400

G

7 7 7 7 7 8 7 7 7 7 7 7 7

77777

C G

054A

OWNER'S

EXISTING

DATA PATCH

PANELS

SPH GRND #1-BSPH GRND #1-A

SPH BSMT #2-B

7 20 7 20 7 20

7 19 7 19 7 19

23 23

SHEET NUMBER

SHEET TITLE

REVISION DATE

CONSULTANT

LOCATION

PHONE

WEBSITE

219 EIGHTH STREET

DES MOINES, IOWA 50309

515-244-7167

WWW.BBSAE.COM

ISSUE DATE

PROJECT NUMBER

SUBMISSION

/8

/4

/2

/4

A

/2

30x42 9 10

/1

B

C

D

E

F

G

H

87654321

9 1087654321

/7

/2

:5

:1

P

M

C

U s e rs

\M G a u l\ D o c u m e n ts

\R e v it

L o c a l F ile s \2

S p e d d in g A

R C

H m a tt h e w g a u l.

rv t

ISSUE FOR BID

S P

E D

D

IN

G H

A L

L

A M

E S

IA

GROUND

LEVEL - FLOOR

PLAN

P

A M

M E

L D

R

IV

E

A M

E S

N A

T

IO

N A

L L

A B

O R

A T

O R

Y

U P

G R

A D

E A

C C

E S

S C

O N

T R

O L

S Y

S T

E M

SPH-E-100

22027

11/08/2024

1/8" = 1'-0"A1 GROUND LEVEL - FLOOR PLAN

DOOR SCHEDULE - GROUND

DOOR NO.

DOOR

KEY

NOTES

WIDTH x HEIGHT

WIDTH HEIGHT

002 3' - 0" 7' - 0" 8

004 3' - 0" 7' - 0" 7

005 3' - 0" 7' - 0" 7

006 3' - 0" 7' - 0" 7

007 3' - 0" 7' - 0" 7

008 3' - 0" 7' - 0" 7

009 3' - 0" 7' - 0" 7

010 3' - 0" 7' - 0" 7

015 6' - 0" 7' - 4" 7

024 3' - 0" 7' - 0" 7

025 3' - 0" 7' - 0" 7

026 3' - 0" 7' - 0" 7

027 3' - 0" 7' - 0" 7

028 3' - 0" 7' - 0" 7

029 3' - 0" 7' - 0" 8

030 3' - 0" 7' - 0" 7, 20

032 3' - 6" 7' - 0" 7, 20

033B 3' - 0" 7' - 0" 7

034B 3' - 0" 7' - 0" 7, 19

035 3' - 0" 7' - 0" 7

036 3' - 0" 7' - 0" 7, 19

037 3' - 0" 7' - 0" 7

038 3' - 0" 7' - 0" 7, 19

039 3' - 0" 7' - 0" 7

040 3' - 0" 7' - 0" 7

041A 3' - 0" 7' - 0" 7

042A 3' - 0" 7' - 0" 7

043 3' - 0" 7' - 0" 7

044 3' - 0" 7' - 0" 7

045 3' - 0" 7' - 0" 7

046 3' - 0" 7' - 0" 7

047 3' - 0" 7' - 0" 7

051 3' - 0" 7' - 0" 7

052 3' - 0" 7' - 0" 7

053 3' - 0" 7' - 0" 7

054 6' - 0" 7' - 4" 8

061 3' - 0" 7' - 0" 7, 20

CG3A 3' - 0" 6' - 8" 7

DG01 3' - 0" 7' - 0" 1

KEYNOTE LEGEND

1 REPLACE EXISTING CARD READER WITH NEW CARD

READER.

2 REPLACE EXISTING ISTAR PRO CONTROLLER WITH

NEW ISTAR ULTRA G2 CONTROLLER.

3 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR ULTRA G2 CONTROLLER.

4 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR EDGE G2 CONTROLLER.

5 ADD NEW ISTAR ULTRA G2 CONTROLLER.

6 UPGRADE EXISTING ISTAR ULTRA G2 CONTROLLER

TO 32 DOORS.

7 NEW WIRELESS LOCKSET.

8 EXISTING WIRED CONTROL TO REMAIN.

9 EXISTING MONITORED DOOR TO REMAIN.

10 NOT USED.

11 NEW HARDWIRED CARD READER, DOOR POSITION

SWITCH, AND MAG LOCK. ROUTE WIRING TO DOOR

CONTROLLER LOCATION AS INDICATED. PATHWAY

BY OWNER, WIRING BY CONTRACTOR.

12 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM B3. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

13 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM 029. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

14 CONTRACTOR TO VERIFY CABLING

DESTINATIONS/UTILIZATION PRIOR TO DEMOLITION.

15 REVISE CABLING/DOOR CONTROL TO ENABLE

MOTORIZED DOOR OPERATOR SWITCH UPON

SUCCESSFUL CARD READ OPERATION.

16 DOOR, FRAME, AND WALL PREPPED FOR FUTURE

DOOR CONTROL.

17 DOOR LOCATION FORMERLY CONTROLLED BY

ACCESS CONTROL SYSTEM.

18 ALTERNATE 1: ADD INTERIOR SUITE DOOR CONTROL.

19 ALTERNATE 2: ADD SECONDARY ENTRY DOOR

CONTROL.

20 ALTERNATE 3: ADD DOOR CONTROL FOR

MECHANICAL, ELECTRICAL, AND CUSTODIAL SPACES.

21 EXISTING WIRELESS LOCKSET

22 NOT USED.

23 MOUNT PIM-400 TRANSCEIVER NEAR LOCATION

SHOWN. IF THE ROOM INDICATED HAS A LAY-IN

CEILING, MOUNT UNIT IN AN ACCESSIBLE LOCATION

ABOVE THE CEILING. IF THE ROOM DOES NOT HAVE

AN ACCESSIBLE LOCATION, LOCATE THE UNIT AS

UP UP

UP

CR

CR

C R

C R

CR

J J

C R

J

C

A

C

A

B

A

136A136D

A

D

104A 104B

144C

C A

C B

C C

A

A

B

A

124C

A

B

127C

A

C

B

113A

D102 S11 S12B

S13

128 156

C110A C110AA

C

118A C118

112B

112-1

C

S11

105D

105C

105B

151A-1

F

141-1

A

-2

B

C

151D

151E

A

A

132AB

B

S12

105D

105C

105B

C110A

118A

111A

S12

132B

151A 151B

140 151C

132A

151D

151E151

151F

104 156

C102

C130

C170

C150C110

132C132D

105A

156A

109 105C11

113114

S11

114A116A

117118119

EC12

120 122 125124

127A 127B

129 130

130A

C15

C14

EC14

ELEV

102104

S13

C12

S12

144A

C13

138136132

A

C

D

153A

C

105A

105B

B

B

C

B

D103

C

PIM-400

AA

PIM-400

A

PIM-400

2 2

SPH 1ST #2

8 8 8 8 8 8 8 8

7 7 7 7 7 7

A

A

SPH 1ST #3-B

SPH 1ST #3

SPH GRND / 1ST #1

SPH 1ST #3-ASPH 1ST #2-B

8 7 197 19

7 197 197 197 19

7 207 20

7 19

7 197 19

7 19 7 19

SHEET NUMBER

SHEET TITLE

REVISION DATE

CONSULTANT

LOCATION

PHONE

WEBSITE

219 EIGHTH STREET

DES MOINES, IOWA 50309

515-244-7167

WWW.BBSAE.COM

ISSUE DATE

PROJECT NUMBER

SUBMISSION

/8

/4

/2

/4

A

/2

30x42 9 10

/1

B

C

D

E

F

G

H

87654321

9 1087654321

/7

/2

:5

:3

P

M

C

U s e rs

\M G a u l\ D o c u m e n ts

\R e v it

L o c a l F ile s \2

S p e d d in g A

R C

H m a tt h e w g a u l.

rv t

ISSUE FOR BID

S P

E D

D

IN

G H

A L

L

A M

E S

IA

LEVEL 1 -

FLOOR PLAN

P

A M

M E

L D

R

IV

E

A M

E S

N A

T

IO

N A

L L

A B

O R

A T

O R

Y

U P

G R

A D

E A

C C

E S

S C

O N

T R

O L

S Y

S T

E M

SPH-E-101

22027

11/08/2024

1/8" = 1'-0"A1 LEVEL 1 - FLOOR PLAN

KEYNOTE LEGEND

1 REPLACE EXISTING CARD READER WITH NEW CARD

READER.

2 REPLACE EXISTING ISTAR PRO CONTROLLER WITH

NEW ISTAR ULTRA G2 CONTROLLER.

3 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR ULTRA G2 CONTROLLER.

4 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR EDGE G2 CONTROLLER.

5 ADD NEW ISTAR ULTRA G2 CONTROLLER.

6 UPGRADE EXISTING ISTAR ULTRA G2 CONTROLLER

TO 32 DOORS.

7 NEW WIRELESS LOCKSET.

8 EXISTING WIRED CONTROL TO REMAIN.

9 EXISTING MONITORED DOOR TO REMAIN.

10 NOT USED.

11 NEW HARDWIRED CARD READER, DOOR POSITION

SWITCH, AND MAG LOCK. ROUTE WIRING TO DOOR

CONTROLLER LOCATION AS INDICATED. PATHWAY

BY OWNER, WIRING BY CONTRACTOR.

12 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM B3. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

13 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM 029. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

14 CONTRACTOR TO VERIFY CABLING

DESTINATIONS/UTILIZATION PRIOR TO DEMOLITION.

15 REVISE CABLING/DOOR CONTROL TO ENABLE

MOTORIZED DOOR OPERATOR SWITCH UPON

SUCCESSFUL CARD READ OPERATION.

16 DOOR, FRAME, AND WALL PREPPED FOR FUTURE

DOOR CONTROL.

17 DOOR LOCATION FORMERLY CONTROLLED BY

ACCESS CONTROL SYSTEM.

18 ALTERNATE 1: ADD INTERIOR SUITE DOOR CONTROL.

19 ALTERNATE 2: ADD SECONDARY ENTRY DOOR

CONTROL.

20 ALTERNATE 3: ADD DOOR CONTROL FOR

MECHANICAL, ELECTRICAL, AND CUSTODIAL SPACES.

21 EXISTING WIRELESS LOCKSET

22 NOT USED.

23 MOUNT PIM-400 TRANSCEIVER NEAR LOCATION

SHOWN. IF THE ROOM INDICATED HAS A LAY-IN

CEILING, MOUNT UNIT IN AN ACCESSIBLE LOCATION

ABOVE THE CEILING. IF THE ROOM DOES NOT HAVE

AN ACCESSIBLE LOCATION, LOCATE THE UNIT AS

HIGH AS PRACTICAL IN THE SPACE, BUT MINIMUM 6”

BELOW THE INACCESSIBLE CEILING.

DOOR SCHEDULE - LEVEL 1

DOOR NO.

DOOR

KEYNOTE

WIDTH x HEIGHT

WIDTH HEIGHT

100 3' - 0" 7' - 0" 7, 20

103 3' - 0" 7' - 0" 7, 20

105 3' - 0" 7' - 0" 7, 19

105A 3' - 0" 7' - 0" 7

105B 3' - 0" 7' - 0" 7, 19

107 3' - 0" 7' - 0" 7

108 3' - 0" 7' - 0" 7

109 3' - 0" 7' - 0" 7

113 3' - 0" 7' - 0" 8

114 3' - 0" 7' - 0" 7, 19

115 3' - 0" 7' - 0" 8

116 3' - 0" 7' - 0" 7

117 3' - 0" 7' - 0" 8

118 3' - 0" 7' - 0" 7, 19

119 3' - 0" 7' - 0" 8

120 3' - 0" 7' - 0" 8

122A 3' - 0" 7' - 0" 7, 19

122B 3' - 0" 7' - 0" 8

124 3' - 0" 7' - 0" 8

124A 3' - 0" 7' - 0" 7, 19

125 3' - 0" 7' - 0" 8

127 3' - 0" 7' - 0" 8

128A 3' - 0" 7' - 0" 8

129 3' - 0" 7' - 0" 8

130 3' - 0" 7' - 0" 8

132A 3' - 0" 7' - 0" 7, 19

132B 3' - 0" 7' - 0" 7

132C 3' - 0" 7' - 0" 7

136B 3' - 0" 7' - 0" 7

136C 3' - 0" 7' - 0" 7

138A 3' - 0" 7' - 0" 7, 19

138B 3' - 0" 7' - 0" 7, 19

138C 3' - 0" 7' - 0" 7, 19

138D 3' - 0" 7' - 0" 7

142 3' - 0" 7' - 0" 7

144A 3' - 0" 7' - 0" 7

144B 3' - 0" 7' - 0" 7, 19

148A 3' - 0" 7' - 0" 7

148B 3' - 0" 7' - 0" 7, 19

151 3' - 0" 7' - 0" 7

152 3' - 0" 7' - 0" 7

153 3' - 0" 7' - 0" 7

160 3' - 0" 7' - 0" 8

C13 3' - 0" 7' - 0" 7

C63 6' - 0" 7' - 4" 7

D101 3' - 4" 7' - 0" 1

D102 3' - 0" 7' - 0" 1

D103 6' - 0" 7' - 4" 1

UPUP

CR

J

J

J

J

C

S23

S21 S22

225B 225A

B

234 236

A

256258

217 216

224 225

233232

234 236

256258

ELEV

C250

C270

C210

C202

C201

C201

C203

212A

224A

C230

C203

224A

C B

C D

C26A

C

201CA

201BA

253258

A

201AA

201B

211A

250C21A

202A

B

214A

201A

258258A

C

B

201BB

258A

201B

201C 255

C22

S22

248 246 244

C26

242241240239238237236235234

232A

232A

232231230229228227226225224222221220

214217219

S21

S23

C21

C24 C25

C23

A

PIM-400

PIM-400

A

PIM-400

A x2

7 7

7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7

SPH 2ND #1

SPH 2ND #2

A

PIM-400

SPH 2ND #2-BSPH 2ND #1-A

SPH 2ND #2-A

SPH 2ND #1-B

7 19

7 197 19

7 197 19

7 20

7 19

7 19

SHEET NUMBER

SHEET TITLE

REVISION DATE

CONSULTANT

LOCATION

PHONE

WEBSITE

219 EIGHTH STREET

DES MOINES, IOWA 50309

515-244-7167

WWW.BBSAE.COM

ISSUE DATE

PROJECT NUMBER

SUBMISSION

/8

/4

/2

/4

A

/2

30x42 9 10

/1

B

C

D

E

F

G

H

87654321

9 1087654321

/7

/2

:5

:4

P

M

C

U s e rs

\M G a u l\ D o c u m e n ts

\R e v it

L o c a l F ile s \2

S p e d d in g A

R C

H m a tt h e w g a u l.

rv t

ISSUE FOR BID

S P

E D

D

IN

G H

A L

L

A M

E S

IA

LEVEL 2 -

FLOOR PLAN

P

A M

M E

L D

R

IV

E

A M

E S

N A

T

IO

N A

L L

A B

O R

A T

O R

Y

U P

G R

A D

E A

C C

E S

S C

O N

T R

O L

S Y

S T

E M

SPH-E-102

22027

11/08/2024

1/8" = 1'-0"A1 LEVEL 2 - FLOOR PLAN

DOOR SCHEDULE - LEVEL 2

DOOR NO.

DOOR

KEY

NOTES

WIDTH x HEIGHT

WIDTH HEIGHT

201A 3' - 0" 7' - 0" 7

201B 3' - 0" 7' - 0" 7, 19

203 2' - 6" 7' - 0" 7, 20

207 3' - 0" 7' - 0" 7

208 3' - 0" 7' - 0" 7

209 3' - 0" 7' - 0" 7

211A 3' - 0" 7' - 0" 7

213 3' - 0" 7' - 0" 7

214 3' - 0" 7' - 0" 7

216 3' - 0" 7' - 0" 7, 19

217 5' - 0" 7' - 0" 7

219 3' - 0" 7' - 0" 7

220 3' - 0" 7' - 0" 7

221 3' - 0" 7' - 0" 7

222 3' - 0" 7' - 0" 7

223 3' - 0" 7' - 0" 7

224 3' - 0" 7' - 0" 7

225 3' - 0" 7' - 0" 7

226 3' - 0" 7' - 0" 7, 19

227 3' - 0" 7' - 0" 7

228 3' - 0" 7' - 0" 7

229 3' - 0" 7' - 0" 7

230 3' - 0" 7' - 0" 7

231 3' - 0" 7' - 0" 7

232 3' - 0" 7' - 0" 7

233 3' - 0" 7' - 0" 7

234 3' - 0" 7' - 0" 7

235 3' - 0" 7' - 0" 7, 19

236 3' - 0" 7' - 0" 7

237 3' - 0" 7' - 0" 7

238 3' - 0" 7' - 0" 7, 19

239 3' - 0" 7' - 0" 7

240 3' - 0" 7' - 0" 7

241 3' - 0" 7' - 0" 7, 19

244 3' - 0" 7' - 0" 7

245 3' - 0" 7' - 0" 7, 19

246 3' - 0" 7' - 0" 7

247 3' - 0" 7' - 0" 7, 19

248 3' - 0" 7' - 0" 7

249 3' - 0" 7' - 0" 7

252 3' - 0" 7' - 0" 7

253 3' - 0" 7' - 0" 7

254 3' - 0" 7' - 0" 7

255 3' - 0" 7' - 0" 7

258 3' - 0" 7' - 0" 7

259 3' - 0" 7' - 0" 7

260 3' - 0" 7' - 0" 7

261 6' - 0" 7' - 4" 7, 20

C22 3' - 0" 7' - 0" 7

C26A 3' - 0" 7' - 0" 7

KEYNOTE LEGEND

1 REPLACE EXISTING CARD READER WITH NEW CARD

READER.

2 REPLACE EXISTING ISTAR PRO CONTROLLER WITH

NEW ISTAR ULTRA G2 CONTROLLER.

3 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR ULTRA G2 CONTROLLER.

4 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR EDGE G2 CONTROLLER.

5 ADD NEW ISTAR ULTRA G2 CONTROLLER.

6 UPGRADE EXISTING ISTAR ULTRA G2 CONTROLLER

TO 32 DOORS.

7 NEW WIRELESS LOCKSET.

8 EXISTING WIRED CONTROL TO REMAIN.

9 EXISTING MONITORED DOOR TO REMAIN.

10 NOT USED.

11 NEW HARDWIRED CARD READER, DOOR POSITION

SWITCH, AND MAG LOCK. ROUTE WIRING TO DOOR

CONTROLLER LOCATION AS INDICATED. PATHWAY

BY OWNER, WIRING BY CONTRACTOR.

12 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM B3. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

13 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM 029. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

14 CONTRACTOR TO VERIFY CABLING

DESTINATIONS/UTILIZATION PRIOR TO DEMOLITION.

15 REVISE CABLING/DOOR CONTROL TO ENABLE

MOTORIZED DOOR OPERATOR SWITCH UPON

SUCCESSFUL CARD READ OPERATION.

16 DOOR, FRAME, AND WALL PREPPED FOR FUTURE

DOOR CONTROL.

17 DOOR LOCATION FORMERLY CONTROLLED BY

ACCESS CONTROL SYSTEM.

18 ALTERNATE 1: ADD INTERIOR SUITE DOOR CONTROL.

19 ALTERNATE 2: ADD SECONDARY ENTRY DOOR

CONTROL.

20 ALTERNATE 3: ADD DOOR CONTROL FOR

MECHANICAL, ELECTRICAL, AND CUSTODIAL SPACES.

21 EXISTING WIRELESS LOCKSET

22 NOT USED.

23 MOUNT PIM-400 TRANSCEIVER NEAR LOCATION

SHOWN. IF THE ROOM INDICATED HAS A LAY-IN

CEILING, MOUNT UNIT IN AN ACCESSIBLE LOCATION

ABOVE THE CEILING. IF THE ROOM DOES NOT HAVE

AN ACCESSIBLE LOCATION, LOCATE THE UNIT AS

UP UP

CR

J J

J

J

A

B

301CB

B

C

S32

S31

301AB

A

301F

A

A

301AC

301E

301DA

D

B

N

IC

301CA

330B

330A

S33

C

C36

C303A C303B

336-1

A

335B

-2

335C

-1329

328B

A

A

C305-1 3

358 356

C

B

A

315B

308A

336332

C303

371 358 356

334 342

C357

C350

318A

C305

305C

305B

305A

C330

308A

C310

C301

C301

C31

S31

C31 301A

301F

301B 356

301C301

301E

301D

C34 S33

302304

314B

314A

314315316318319 317

320 321 322 323 324 325 326 329 330 331 334 336

340A 340B

C36

C35

C73

344347

S32

314B

A

PIM-400

A

A

PIM-400

PIM-400

SPH 3RD #2

777777

777777777 777

7 7 7 7

PIM-400

SPH 3RD #1-BSPH 3RD #2-B

SPH 3RD #1-A

SPH 3RD #2-A

SPH 3RD #1

A

7 19 7 19

7 19

7 20

SHEET NUMBER

SHEET TITLE

REVISION DATE

CONSULTANT

LOCATION

PHONE

WEBSITE

219 EIGHTH STREET

DES MOINES, IOWA 50309

515-244-7167

WWW.BBSAE.COM

ISSUE DATE

PROJECT NUMBER

SUBMISSION

/8

/4

/2

/4

A

/2

30x42 9 10

/1

B

C

D

E

F

G

H

87654321

9 1087654321

/7

/2

:5

:5

P

M

C

U s e rs

\M G a u l\ D o c u m e n ts

\R e v it

L o c a l F ile s \2

S p e d d in g A

R C

H m a tt h e w g a u l.

rv t

ISSUE FOR BID

S P

E D

D

IN

G H

A L

L

A M

E S

IA

LEVEL 3 -

FLOOR PLAN

P

A M

M E

L D

R

IV

E

A M

E S

N A

T

IO

N A

L L

A B

O R

A T

O R

Y

U P

G R

A D

E A

C C

E S

S C

O N

T R

O L

S Y

S T

E M

SPH-E-103

22027

11/08/2024

1/8" = 1'-0"A1 LEVEL 3 - FLOOR PLAN

DOOR SCHEDULE - LEVEL 3

DOOR NO.

DOOR

KEY

NOTES

WIDTH x HEIGHT

WIDTH HEIGHT

301AB 3' - 0" 7' - 0" 8

301CB 3' - 0" 7' - 0" 8

301DA 3' - 0" 7' - 0" 8

301E 3' - 0" 7' - 0" 8

303 3' - 0" 7' - 0" 7, 20

307 3' - 0" 7' - 0" 7

308 3' - 0" 7' - 0" 7

309 3' - 0" 7' - 0" 7

314 3' - 0" 7' - 0" 7

314A 3' - 0" 7' - 0" 7

314B 3' - 0" 7' - 0" 7

315 3' - 0" 7' - 0" 7

316 3' - 0" 7' - 0" 7

317 3' - 0" 7' - 0" 7, 19

318 3' - 0" 7' - 0" 7

319 3' - 0" 7' - 0" 7

320 3' - 0" 7' - 0" 7

321 3' - 0" 7' - 0" 7

322 3' - 0" 7' - 0" 7

323 3' - 0" 7' - 0" 7

324 3' - 0" 7' - 0" 7

325 3' - 0" 7' - 0" 7

326 3' - 0" 7' - 0" 7

328 3' - 0" 7' - 0" 7, 19

329 3' - 0" 7' - 0" 7

330 3' - 0" 7' - 0" 7

332 5' - 0" 7' - 0" 7

336 5' - 0" 7' - 0" 7

339 3' - 0" 7' - 0" 7

340 3' - 0" 7' - 0" 7

342 3' - 0" 7' - 0" 7

343 5' - 0" 7' - 0" 7, 19

346 3' - 0" 7' - 0" 7

347 3' - 0" 7' - 0" 7

348 3' - 0" 7' - 0" 7

349 3' - 0" 7' - 0" 7

352 3' - 0" 7' - 0" 7

353 3' - 0" 7' - 0" 7

354 3' - 0" 7' - 0" 7

355 3' - 0" 7' - 0" 7

356 3' - 0" 7' - 0" 7

357 3' - 0" 7' - 0" 7

361 6' - 0" 7' - 4" 7, 20

C34 6' - 0" 7' - 4" 8

C36 6' - 0" 7' - 0" 8

KEYNOTE LEGEND

1 REPLACE EXISTING CARD READER WITH NEW CARD

READER.

2 REPLACE EXISTING ISTAR PRO CONTROLLER WITH

NEW ISTAR ULTRA G2 CONTROLLER.

3 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR ULTRA G2 CONTROLLER.

4 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR EDGE G2 CONTROLLER.

5 ADD NEW ISTAR ULTRA G2 CONTROLLER.

6 UPGRADE EXISTING ISTAR ULTRA G2 CONTROLLER

TO 32 DOORS.

7 NEW WIRELESS LOCKSET.

8 EXISTING WIRED CONTROL TO REMAIN.

9 EXISTING MONITORED DOOR TO REMAIN.

10 NOT USED.

11 NEW HARDWIRED CARD READER, DOOR POSITION

SWITCH, AND MAG LOCK. ROUTE WIRING TO DOOR

CONTROLLER LOCATION AS INDICATED. PATHWAY

BY OWNER, WIRING BY CONTRACTOR.

12 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM B3. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

13 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM 029. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

14 CONTRACTOR TO VERIFY CABLING

DESTINATIONS/UTILIZATION PRIOR TO DEMOLITION.

15 REVISE CABLING/DOOR CONTROL TO ENABLE

MOTORIZED DOOR OPERATOR SWITCH UPON

SUCCESSFUL CARD READ OPERATION.

16 DOOR, FRAME, AND WALL PREPPED FOR FUTURE

DOOR CONTROL.

17 DOOR LOCATION FORMERLY CONTROLLED BY

ACCESS CONTROL SYSTEM.

18 ALTERNATE 1: ADD INTERIOR SUITE DOOR CONTROL.

19 ALTERNATE 2: ADD SECONDARY ENTRY DOOR

CONTROL.

20 ALTERNATE 3: ADD DOOR CONTROL FOR

MECHANICAL, ELECTRICAL, AND CUSTODIAL SPACES.

21 EXISTING WIRELESS LOCKSET

22 NOT USED.

23 MOUNT PIM-400 TRANSCEIVER NEAR LOCATION

SHOWN. IF THE ROOM INDICATED HAS A LAY-IN

CEILING, MOUNT UNIT IN AN ACCESSIBLE LOCATION

ABOVE THE CEILING. IF THE ROOM DOES NOT HAVE

AN ACCESSIBLE LOCATION, LOCATE THE UNIT AS

402 403

401A

SHEET NUMBER

SHEET TITLE

REVISION DATE

CONSULTANT

LOCATION

PHONE

WEBSITE

219 EIGHTH STREET

DES MOINES, IOWA 50309

515-244-7167

WWW.BBSAE.COM

ISSUE DATE

PROJECT NUMBER

SUBMISSION

/8

/4

/2

/4

A

/2

30x42 9 10

/1

B

C

D

E

F

G

H

87654321

9 1087654321

/7

/2

:1 :3

P

M

C

U s e rs

\M G a u l\ D o c u m e n ts

\R e v it

L o c a l F ile s \2

S p e d d in g A

R C

H m a tt h e w g a u l.

rv t

ISSUE FOR BID

S P

E D

D

IN

G H

A L

L

A M

E S

IA

ROOF - FLOOR

PLAN

P

A M

M E

L D

R

IV

E

A M

E S

N A

T

IO

N A

L L

A B

O R

A T

O R

Y

U P

G R

A D

E A

C C

E S

S C

O N

T R

O L

S Y

S T

E M

SPH-E-104

22027

11/08/2024

1/8" = 1'-0"A1 ROOF LEVEL

DOOR SCHEDULE - ROOF

DOOR NO.

DOOR

KEY

NOTES

WIDTH x HEIGHT

WIDTH HEIGHT

KEYNOTE LEGEND

1 REPLACE EXISTING CARD READER WITH NEW CARD

READER.

2 REPLACE EXISTING ISTAR PRO CONTROLLER WITH

NEW ISTAR ULTRA G2 CONTROLLER.

3 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR ULTRA G2 CONTROLLER.

4 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR EDGE G2 CONTROLLER.

5 ADD NEW ISTAR ULTRA G2 CONTROLLER.

6 UPGRADE EXISTING ISTAR ULTRA G2 CONTROLLER

TO 32 DOORS.

7 NEW WIRELESS LOCKSET.

8 EXISTING WIRED CONTROL TO REMAIN.

9 EXISTING MONITORED DOOR TO REMAIN.

10 NOT USED.

11 NEW HARDWIRED CARD READER, DOOR POSITION

SWITCH, AND MAG LOCK. ROUTE WIRING TO DOOR

CONTROLLER LOCATION AS INDICATED. PATHWAY

BY OWNER, WIRING BY CONTRACTOR.

12 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM B3. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

13 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM 029. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

14 CONTRACTOR TO VERIFY CABLING

DESTINATIONS/UTILIZATION PRIOR TO DEMOLITION.

15 REVISE CABLING/DOOR CONTROL TO ENABLE

MOTORIZED DOOR OPERATOR SWITCH UPON

SUCCESSFUL CARD READ OPERATION.

16 DOOR, FRAME, AND WALL PREPPED FOR FUTURE

DOOR CONTROL.

17 DOOR LOCATION FORMERLY CONTROLLED BY

ACCESS CONTROL SYSTEM.

18 ALTERNATE 1: ADD INTERIOR SUITE DOOR CONTROL.

19 ALTERNATE 2: ADD SECONDARY ENTRY DOOR

CONTROL.

20 ALTERNATE 3: ADD DOOR CONTROL FOR

MECHANICAL, ELECTRICAL, AND CUSTODIAL SPACES.

21 EXISTING WIRELESS LOCKSET

22 NOT USED.

23 MOUNT PIM-400 TRANSCEIVER NEAR LOCATION

SHOWN. IF THE ROOM INDICATED HAS A LAY-IN

CEILING, MOUNT UNIT IN AN ACCESSIBLE LOCATION

ABOVE THE CEILING. IF THE ROOM DOES NOT HAVE

AN ACCESSIBLE LOCATION, LOCATE THE UNIT AS

CB01

B03

234561789

CB01

B04

B

B04

1011121314151617181920212223. .

SHEET NUMBER

SHEET TITLE

REVISION DATE

CONSULTANT

LOCATION

PHONE

WEBSITE

219 EIGHTH STREET

DES MOINES, IOWA 50309

515-244-7167

WWW.BBSAE.COM

ISSUE DATE

PROJECT NUMBER

SUBMISSION

/8

/4

/2

/4

A

/2

30x42 9 10

/1

B

C

D

E

F

G

H

87654321

9 1087654321

/7

/2

:0 :1

P

M

C

U s e rs

\M G a u l\ D o c u m e n ts

\R e v it

L o c a l F ile s \2

T

A S

F A

R C

H m a tt h e w g a u l.

rv t

ISSUE FOR BID

T E

C H

N

IC

A L A

N D

A D

M

IN

IS

T

R A

T

IV

E S

E R

V

IC

E S

B U

IL

D

IN

G

A M

E S

IA

BASEMENT

LEVEL - FLOOR

PLAN

P

A M

M E

L D

R

IV

E

A M

E S

N A

T

IO

N A

L L

A B

O R

A T

O R

Y

U P

G R

A D

E A

C C

E S

S C

O N

T R

O L

S Y

S T

E M

TASF-E-000

22027

11/08/2024

1/8" = 1'-0"A3 BASEMENT LEVEL - FLOOR PLAN

KEYNOTE LEGEND

1 REPLACE EXISTING CARD READER WITH NEW CARD

READER.

2 REPLACE EXISTING ISTAR PRO CONTROLLER WITH

NEW ISTAR ULTRA G2 CONTROLLER.

3 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR ULTRA G2 CONTROLLER.

4 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR EDGE G2 CONTROLLER.

5 ADD NEW ISTAR ULTRA G2 CONTROLLER.

6 UPGRADE EXISTING ISTAR ULTRA G2 CONTROLLER

TO 32 DOORS.

7 NEW WIRELESS LOCKSET.

8 EXISTING WIRED CONTROL TO REMAIN.

9 EXISTING MONITORED DOOR TO REMAIN.

10 NOT USED.

11 NEW HARDWIRED CARD READER, DOOR POSITION

SWITCH, AND MAG LOCK. ROUTE WIRING TO DOOR

CONTROLLER LOCATION AS INDICATED. PATHWAY

BY OWNER, WIRING BY CONTRACTOR.

12 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM B3. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

13 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM 029. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

14 CONTRACTOR TO VERIFY CABLING

DESTINATIONS/UTILIZATION PRIOR TO DEMOLITION.

15 REVISE CABLING/DOOR CONTROL TO ENABLE

MOTORIZED DOOR OPERATOR SWITCH UPON

SUCCESSFUL CARD READ OPERATION.

16 DOOR, FRAME, AND WALL PREPPED FOR FUTURE

DOOR CONTROL.

17 DOOR LOCATION FORMERLY CONTROLLED BY

ACCESS CONTROL SYSTEM.

18 ALTERNATE 1: ADD INTERIOR SUITE DOOR CONTROL.

19 ALTERNATE 2: ADD SECONDARY ENTRY DOOR

CONTROL.

20 ALTERNATE 3: ADD DOOR CONTROL FOR

MECHANICAL, ELECTRICAL, AND CUSTODIAL SPACES.

21 EXISTING WIRELESS LOCKSET

22 NOT USED.

23 MOUNT PIM-400 TRANSCEIVER NEAR LOCATION

SHOWN. IF THE ROOM INDICATED HAS A LAY-IN

CEILING, MOUNT UNIT IN AN ACCESSIBLE LOCATION

ABOVE THE CEILING. IF THE ROOM DOES NOT HAVE

AN ACCESSIBLE LOCATION, LOCATE THE UNIT AS

HIGH AS PRACTICAL IN THE SPACE, BUT MINIMUM 6”

BELOW THE INACCESSIBLE CEILING.

DOOR SCHEDULE - BASEMENT LEVEL

DOOR NO.

DOOR

KEYNOTE

WIDTH x HEIGHT

WIDTH HEIGHT

B03 3' - 0" 7' - 0" 8

B04 3' - 6" 7' - 0" 8

CB01 3' - 0" 7' - 0" 8

BASEMENT LEVEL: 3

C R

CR

CR

CG31

CG01-1

G

G18

G

G15

G13

G

G25

C24

G23 G21

G

C G

A

G

CG32C

G

G

G

G46

G47

G48

G

G A

G40-1

G41

G35-1

G

G22B

G22A

G58 G56A

G56B

CG50CG10A CG10AB

CG31C

C G

G

G16

G15

G29

G28

C24

G26

G43

G58

G53

CG01

G20

G40C

CG32A

CG32C

G35

G34

G34A

G40B

G40

CG03

G22

G11

G12G14A

G14

G17A

CG02

CG10CG10A

G19

G21 G23

G42 G44

G46

G45

G18

CG30G25

G41CG32B

G47

G48

G33

CG50

G40A G49

G13

CG70

G71

G56

G04 G56A

G52 G51

G27

G17

CG57

CG01A

C G

-2

TASF GND FLR #2

TASF GND FLR #1

G -1

G -2

9 9

G719

8 8

SHEET NUMBER

SHEET TITLE

REVISION DATE

CONSULTANT

LOCATION

PHONE

WEBSITE

219 EIGHTH STREET

DES MOINES, IOWA 50309

515-244-7167

WWW.BBSAE.COM

ISSUE DATE

PROJECT NUMBER

SUBMISSION

/8

/4

/2

/4

A

/2

30x42 9 10

/1

B

C

D

E

F

G

H

87654321

9 1087654321

/7

/2

:0 :2

P

M

C

U s e rs

\M G a u l\ D o c u m e n ts

\R e v it

L o c a l F ile s \2

T

A S

F A

R C

H m a tt h e w g a u l.

rv t

ISSUE FOR BID

T E

C H

N

IC

A L A

N D

A D

M

IN

IS

T

R A

T

IV

E S

E R

V

IC

E S

B U

IL

D

IN

G

A M

E S

IA

GROUND

LEVEL - FLOOR

PLAN

P

A M

M E

L D

R

IV

E

A M

E S

N A

T

IO

N A

L L

A B

O R

A T

O R

Y

U P

G R

A D

E A

C C

E S

S C

O N

T R

O L

S Y

S T

E M

TASF-E-100

22027

11/08/2024

1/8" = 1'-0"A3 GROUND LEVEL - FLOOR PLAN

KEYNOTE LEGEND

1 REPLACE EXISTING CARD READER WITH NEW CARD

READER.

2 REPLACE EXISTING ISTAR PRO CONTROLLER WITH

NEW ISTAR ULTRA G2 CONTROLLER.

3 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR ULTRA G2 CONTROLLER.

4 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR EDGE G2 CONTROLLER.

5 ADD NEW ISTAR ULTRA G2 CONTROLLER.

6 UPGRADE EXISTING ISTAR ULTRA G2 CONTROLLER

TO 32 DOORS.

7 NEW WIRELESS LOCKSET.

8 EXISTING WIRED CONTROL TO REMAIN.

9 EXISTING MONITORED DOOR TO REMAIN.

10 NOT USED.

11 NEW HARDWIRED CARD READER, DOOR POSITION

SWITCH, AND MAG LOCK. ROUTE WIRING TO DOOR

CONTROLLER LOCATION AS INDICATED. PATHWAY

BY OWNER, WIRING BY CONTRACTOR.

12 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM B3. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

13 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM 029. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

14 CONTRACTOR TO VERIFY CABLING

DESTINATIONS/UTILIZATION PRIOR TO DEMOLITION.

15 REVISE CABLING/DOOR CONTROL TO ENABLE

MOTORIZED DOOR OPERATOR SWITCH UPON

SUCCESSFUL CARD READ OPERATION.

16 DOOR, FRAME, AND WALL PREPPED FOR FUTURE

DOOR CONTROL.

17 DOOR LOCATION FORMERLY CONTROLLED BY

ACCESS CONTROL SYSTEM.

18 ALTERNATE 1: ADD INTERIOR SUITE DOOR CONTROL.

19 ALTERNATE 2: ADD SECONDARY ENTRY DOOR

CONTROL.

20 ALTERNATE 3: ADD DOOR CONTROL FOR

MECHANICAL, ELECTRICAL, AND CUSTODIAL SPACES.

21 EXISTING WIRELESS LOCKSET

22 NOT USED.

23 MOUNT PIM-400 TRANSCEIVER NEAR LOCATION

SHOWN. IF THE ROOM INDICATED HAS A LAY-IN

CEILING, MOUNT UNIT IN AN ACCESSIBLE LOCATION

ABOVE THE CEILING. IF THE ROOM DOES NOT HAVE

AN ACCESSIBLE LOCATION, LOCATE THE UNIT AS

HIGH AS PRACTICAL IN THE SPACE, BUT MINIMUM 6”

BELOW THE INACCESSIBLE CEILING.

DOOR SCHEDULE - GROUND LEVEL

DOOR NO.

DOOR

KEYNOTE

WIDTH x HEIGHT

WIDTH HEIGHT

CG01-1 3' - 0" 7' - 0" 9

CG10A 6' - 0" 7' - 4" 15

CG31-2 3' - 0" 7' - 0" 1

CG31C 3' - 6" 7' - 0" 9

G04 3' - 0" 7' - 0" 14

G11 3' - 0" 7' - 0" 8

G20-1 4' - 0" 7' - 0" 9

G20-2 4' - 0" 7' - 0" 9

G22 3' - 0" 7' - 0" 8

G34 3' - 0" 7' - 0" 8

G35-1 3' - 0" 7' - 0" 8

G40-1 3' - 0" 7' - 0" 8

G49 3' - 0" 7' - 0" 8

G71 3' - 0" 7' - 0" 9

GROUND LEVEL: 14

UP

UP

UP UP

UP

UP

UP

UP

C R

CR

CR

S11

105D

105C

105B

C110A

118A

111A

S12

132B

151A 151B

140 151C

132A

151D

151E151

151F

C102

C130

C170

C150C110

132C132D

105A

156A

128 156

C110A C110AA

C

118A C118

112B

112-1

C

S11

105D

105C

105B

151A-1

F

141-1

A

-2

B

C

151D

151E

A

A

132AB

B

S12

C

TASF 1ST FLR #1

16 16 16 16

D

C

16 16 16

1/8" = 1'-0"A3 LEVEL 1 - FLOOR PLAN

SHEET NUMBER

SHEET TITLE

REVISION DATE

CONSULTANT

LOCATION

PHONE

WEBSITE

219 EIGHTH STREET

DES MOINES, IOWA 50309

515-244-7167

WWW.BBSAE.COM

ISSUE DATE

PROJECT NUMBER

SUBMISSION

/8

/4

/2

/4

A

/2

30x42 9 10

/1

B

C

D

E

F

G

H

87654321

9 1087654321

/7

/2

:0 :2

P

M

C

U s e rs

\M G a u l\ D o c u m e n ts

\R e v it

L o c a l F ile s \2

T

A S

F A

R C

H m a tt h e w g a u l.

rv t

ISSUE FOR BID

T E

C H

N

IC

A L A

N D

A D

M

IN

IS

T

R A

T

IV

E S

E R

V

IC

E S

B U

IL

D

IN

G

A M

E S

IA

LEVEL 1 -

FLOOR PLAN

P

A M

M E

L D

R

IV

E

A M

E S

N A

T

IO

N A

L L

A B

O R

A T

O R

Y

U P

G R

A D

E A

C C

E S

S C

O N

T R

O L

S Y

S T

E M

TASF-E-101

22027

11/08/2024

KEYNOTE LEGEND

1 REPLACE EXISTING CARD READER WITH NEW CARD

READER.

2 REPLACE EXISTING ISTAR PRO CONTROLLER WITH

NEW ISTAR ULTRA G2 CONTROLLER.

3 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR ULTRA G2 CONTROLLER.

4 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR EDGE G2 CONTROLLER.

5 ADD NEW ISTAR ULTRA G2 CONTROLLER.

6 UPGRADE EXISTING ISTAR ULTRA G2 CONTROLLER

TO 32 DOORS.

7 NEW WIRELESS LOCKSET.

8 EXISTING WIRED CONTROL TO REMAIN.

9 EXISTING MONITORED DOOR TO REMAIN.

10 NOT USED.

11 NEW HARDWIRED CARD READER, DOOR POSITION

SWITCH, AND MAG LOCK. ROUTE WIRING TO DOOR

CONTROLLER LOCATION AS INDICATED. PATHWAY

BY OWNER, WIRING BY CONTRACTOR.

12 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM B3. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

13 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM 029. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

14 CONTRACTOR TO VERIFY CABLING

DESTINATIONS/UTILIZATION PRIOR TO DEMOLITION.

15 REVISE CABLING/DOOR CONTROL TO ENABLE

MOTORIZED DOOR OPERATOR SWITCH UPON

SUCCESSFUL CARD READ OPERATION.

16 DOOR, FRAME, AND WALL PREPPED FOR FUTURE

DOOR CONTROL.

17 DOOR LOCATION FORMERLY CONTROLLED BY

ACCESS CONTROL SYSTEM.

18 ALTERNATE 1: ADD INTERIOR SUITE DOOR CONTROL.

19 ALTERNATE 2: ADD SECONDARY ENTRY DOOR

CONTROL.

20 ALTERNATE 3: ADD DOOR CONTROL FOR

MECHANICAL, ELECTRICAL, AND CUSTODIAL SPACES.

21 EXISTING WIRELESS LOCKSET

22 NOT USED.

23 MOUNT PIM-400 TRANSCEIVER NEAR LOCATION

SHOWN. IF THE ROOM INDICATED HAS A LAY-IN

CEILING, MOUNT UNIT IN AN ACCESSIBLE LOCATION

ABOVE THE CEILING. IF THE ROOM DOES NOT HAVE

AN ACCESSIBLE LOCATION, LOCATE THE UNIT AS

HIGH AS PRACTICAL IN THE SPACE, BUT MINIMUM 6”

BELOW THE INACCESSIBLE CEILING.

DOOR SCHEDULE - LEVEL 1

DOOR NO.

DOOR

KEYNOTE

WIDTH x HEIGHT

WIDTH HEIGHT

104 3' - 0" 7' - 0" 14

105B 3' - 0" 7' - 0" 8

105C 3' - 0" 7' - 0" 8

105D 3' - 0" 7' - 0" 8

112-1 3' - 0" 7' - 0" 8

132 3' - 0" 7' - 0" 8

140 3' - 0" 7' - 0" 8

141-1 3' - 0" 7' - 0" 8

151A-1 3' - 0" 7' - 0" 8

C110A 6' - 0" 7' - 4" 1

C111 3' - 0" 7' - 0" 8

C118 3' - 0" 7' - 0" 8

C130 3' - 0" 7' - 0" 1

LEVEL 1: 13

225B 225A

B

234 236

A

256258

217 216

233232

234 236

256258

ELEV

C250

C270

C210

C202 C201

C201

C203

212A

224A

213 212

C230

C203

224A

C

TASF 2ND FLR #1

SHEET NUMBER

SHEET TITLE

REVISION DATE

CONSULTANT

LOCATION

PHONE

WEBSITE

219 EIGHTH STREET

DES MOINES, IOWA 50309

515-244-7167

WWW.BBSAE.COM

ISSUE DATE

PROJECT NUMBER

SUBMISSION

/8

/4

/2

/4

A

/2

30x42 9 10

/1

B

C

D

E

F

G

H

87654321

9 1087654321

/7

/2

:0 :3

P

M

C

U s e rs

\M G a u l\ D o c u m e n ts

\R e v it

L o c a l F ile s \2

T

A S

F A

R C

H m a tt h e w g a u l.

rv t

ISSUE FOR BID

T E

C H

N

IC

A L A

N D

A D

M

IN

IS

T

R A

T

IV

E S

E R

V

IC

E S

B U

IL

D

IN

G

A M

E S

IA

LEVEL 2 -

FLOOR PLAN

P

A M

M E

L D

R

IV

E

A M

E S

N A

T

IO

N A

L L

A B

O R

A T

O R

Y

U P

G R

A D

E A

C C

E S

S C

O N

T R

O L

S Y

S T

E M

TASF-E-102

22027

11/08/2024

1/8" = 1'-0"A3 LEVEL 2 - FLOOR PLAN

KEYNOTE LEGEND

1 REPLACE EXISTING CARD READER WITH NEW CARD

READER.

2 REPLACE EXISTING ISTAR PRO CONTROLLER WITH

NEW ISTAR ULTRA G2 CONTROLLER.

3 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR ULTRA G2 CONTROLLER.

4 REPLACE EXISTING ISTAR EDGE CONTROLLER(S)

WITH NEW ISTAR EDGE G2 CONTROLLER.

5 ADD NEW ISTAR ULTRA G2 CONTROLLER.

6 UPGRADE EXISTING ISTAR ULTRA G2 CONTROLLER

TO 32 DOORS.

7 NEW WIRELESS LOCKSET.

8 EXISTING WIRED CONTROL TO REMAIN.

9 EXISTING MONITORED DOOR TO REMAIN.

10 NOT USED.

11 NEW HARDWIRED CARD READER, DOOR POSITION

SWITCH, AND MAG LOCK. ROUTE WIRING TO DOOR

CONTROLLER LOCATION AS INDICATED. PATHWAY

BY OWNER, WIRING BY CONTRACTOR.

12 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM B3. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

13 NEW TELECOM OUTLETS AND CABLING TO DATA

RACK IN ROOM 029. MATERIAL BY CONTRACTOR,

INSTALLATION AND TESTING BY OWNER.

14 CONTRACTOR TO VERIFY CABLING

DESTINATIONS/UTILIZATION PRIOR TO DEMOLITION.

15 REVISE CABLING/DOOR CONTROL TO ENABLE

MOTORIZED DOOR OPERATOR SWITCH UPON

SUCCESSFUL CARD READ OPERATION.

16 DOOR, FRAME, AND WALL PREPPED FOR FUTURE

DOOR CONTROL.

17 DOOR LOCATION FORMERLY CONTROLLED BY

ACCESS CONTROL SYSTEM.

18 ALTERNATE 1: ADD INTERIOR SUITE DOOR CONTROL.

19 ALTERNATE 2: ADD SECONDARY ENTRY DOOR

CONTROL.

20 ALTERNATE 3: ADD DOOR CONTROL FOR

MECHANICAL, ELECTRICAL, AND CUSTODIAL SPACES.

21 EXISTING WIRELESS LOCKSET

22 NOT USED.

23 MOUNT PIM-400 TRANSCEIVER NEAR LOCATION

SHOWN. IF THE ROOM INDICATED HAS A LAY-IN

CEILING, MOUNT UNIT IN AN ACCESSIBLE LOCATION

ABOVE THE CEILING. IF THE ROOM DOES NOT HAVE

AN ACCESSIBLE LOCATION, LOCATE THE UNIT AS

HIGH AS PRACTICAL IN THE SPACE, BUT MINIMUM 6”

BELOW THE INACCESSIBLE CEILING.

DOOR SCHEDULE - LEVEL 2

DOOR NO.

DOOR

KEYNOTE

WIDTH x HEIGHT

WIDTH HEIGHT

204 3' - 0" 7' - 0" 8

205 3' - 0" 7' - 0" 8

211 3' - 0" 7' - 0" 8

224A 3' - 0" 7' - 0" 8

225A 3' - 0" 7' - 0" 8

231 3' - 0" 7' - 0" 8

252 3' - 0" 7' - 0" 8

254 3' - 0" 7' - 0" 8

C230 3' - 0" 7' - 0" 1

LEVEL 2: 9

C303A C303B

336-1

A

335B

-2

335C

-1329

328B

A

A

C305-1 3

358 356

C

B

A

315B

A

317A

C303

358 356

334 342

C357

C350

318A

318 317

C305

305C

305B

305A

325324

C330

308A

C310

C301

C

TASF 3RD FLR #1

SHEET NUMBER

SHEET TITLE

REVISION DATE

CONSULTANT

LOCATION

PHONE

WEBSITE