RFB944001-01 - Drawings.pdf

PDF 5 MB Posted

Attached to
DAS CC Historical Building Elevator Replacements PH1
Solicitation number
RFB944001-01
Issued by
Polk County, Iowa

About this file

Summary of RFB944001-01 - State Historical Building Elevator Replacements

This document is a set of architectural drawings and specifications prepared by OPN Architects for the State of Iowa's Department of Cultural Affairs regarding the modernization and replacement of five elevators at the State Historical Building located at 600 E Locust Street, Des Moines, Iowa. The project encompasses the complete replacement of elevator systems 3, 4, and 5 (identified as 6514, 6512, and 6513 respectively), with work involving demolition of existing equipment, installation of new traction elevators with updated controls, and comprehensive mechanical and electrical system modifications. The scope includes new elevator cabs with brushed stainless steel finishes, updated signage and controls with ADA-compliant braille, new elevator machinery and controllers, replacement of pit ladders, provision of new shaft lighting, and integration with fire alarm systems requiring hat flash, primary recall, secondary recall, and shunt trip capabilities. The project maintains existing shaft rails and counterweights where feasible and requires all work to comply with the 2024 International Building Code, 2024 International Fire Code, 2024 International Existing Building Code, 2026 Iowa State Elevator Code, and applicable state mechanical, plumbing, and electrical codes.

The construction will utilize the basement level for material access and transport, with all corridors remaining open for building operations throughout construction. The architect team includes OPN Architects as lead, DCI Group as mechanical engineer, KCL Engineering as both mechanical and electrical engineer, and Lerch Bates as construction manager. The project includes electrical work involving new dedicated circuits for elevator lighting, disconnects, and fire alarm system integration, with specific coordination required between existing building systems and new equipment. Cost information, bid submission requirements, and contract award details are not included in these drawing sets, which represent the 06/10/26 bid issue set and subsequent 06/16/26 construction document set. All penetrations in fire-rated assemblies must be sealed with appropriate firestopping, and contractors are responsible for protecting existing finishes and patching any demolition-related damage to floors and wall surfaces.

View the file

Other files

File Type Posted
RFB944001-01 - Project Manual.pdf PDF
RFB944001-01 - Bid Form.pdf PDF
RFB944001-01 - Notice to Bidders.pdf PDF
Bid Opening - Microsoft Teams Meeting.html HTML file
Bidding Documents.html HTML file
IMPACS Electronic Procurement System.html HTML file
Targeted Small Business Directory.html HTML file
Targeted Small Business Directory.js JS file
1404742-event.pdf PDF
Iowa Nondiscrimination Clause Form 22.pdf PDF
DAS Terms and Conditions.html HTML file
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

IBC Chapter 2 - Use and Occupancy Classification

Primary Occupancy:

The use and occupancy classification of the existing building are unchanged.

IBC Chapter 5 - General Building Heights and Areas

Existing building use and size to remain unchanged.

IBC Chapter 6 - Types of Construction

The type of construction for the existing building is unchanged.

IBC Chaper 7 - Fire and Smoke Protection Features

New construction is limited and existing construction is not being modified.

For construction purposes, shaft is considered to be 2 HR construction.

IBC Chapter 8 - Interior Finishes New construction is limited and matches existing interior finishes.

IBC Chapter 10 - Means of Egress

All means of egress are being maintained in the existing building.

IBC Chapter 30 - Elevators and Conveying Systems

Fire resistance rated construction is provided at the elevator machine room.

Smoke protection at hoistway openings is not required per IBC 3006.2.

IBE Chapter 34 Existing Structures:

The updates to the existing building conform to the requirements of the code for new construction and are to be made with the same materials of which the original building is constructed. The existing building is in compliance with the mandatory fire safety requirements, the mandatory means of egress requirements, and the general safety requirements of this chapter.

Iowa Administrative Code, Chapter 16, Division VII - Accessibility Requirements For Facilities Used by the General Public:

Accessibility within the building will be maintained.

Iowa Administrative Code, Chapter 72 - Conveyances Installed on or After January 1, 1975

Elevator pit sump pump currently exists, and will be maintained.

NFPA-13 Chapter 8 - Section 8.15.5

Building is fully sprinklered. In accordance with NFPA 13-2013, sprinkler coverage will not be provided in the new elevator machine room nor at the bottom of the elevator pit (traction elevators). A sprinkler is not required a the top of the hoistway due to compliance with 8.15.5.6.

APPLICABLE CODE INFORMATION

THE PROJECT SHALL COMPLY WITH THE FOLLOWING CODES

2024 INTERNATIONAL BUILDING CODE AS ADOPTED BY IOWA ADMINISTRATIVE RULE CHAPTERS 481-280 AND 481-301

2010 AMERICANS WITH DISABILITIES ACT AS ADOPTED BY IOWA ADMINISTRATIVE RULE CHAPTER 481-301

STATE MECHANICAL CODE AS ADOPTED BY THE DEPARTMENT OF PUBLIC HEALTH IOWA ADMINISTRATIVE RULE CHAPTER 481-426

STATE PLUMBING CODE AS ADOPTED BY THE DEPARTMENT OF PUBLIC HEALTH IOWA ADMINISTRATIVE RULE CHAPTER 481-425

2024 INTERNATIONAL FIRE CODE AS ADOPTED BY IOWA ADMINISTRATIVE RULE CHAPTERS 481-280

STATE ELECTRICAL CODE AS ADOPTED BY THE STATE ELECTRICAL LICENSING BOARD IOWA ADMINISTRATIVE RULE CHAPTER 481-404

2024 INTERNATIONAL EXISTING BUILDING CODE AS ADOPTED BY IOWA ADMINISTRATIVE RULE CHAPTERS 481-301

2026 IOWA STATE ELEVATOR CODE

100 Court Ave. Suite 100, Des Moines, IA 50309

P: 515-309-0722 F: 515-309-0725 www.opnarchitects.com

ARCHITECT

OPN ARCHITECTS

100 COURT AVENUE

DES MOINES, IA 50309

DCI GROUP

220 SE 6th STREET, SUITE 200

DES MOINES, IA 50309

ELEVATOR CONSULTANTMECHANICAL ENGINEER

KCL ENGINEERING

300 4th STREET

WEST DES MOINES, IA 50317

ELECTRICAL ENGINEER

KCL ENGINEERING

300 4th STREET

WEST DES MOINES, IA 50317

CONSTRUCTION MANAGER

LERCH BATES

7625 GOLDEN TRIANGLE DRIVE, SUITE T

EDEN PRAIRIE, MN 55344

STATE OF IOWA - 9440.01 - STATE HISTORICAL

BUILDING ELEVATOR REPLACEMENTS

600 E LOCUST STREET, DES MOINES, IA 50319

A G

B

ID

I

S S

U E

S E

T

/1

/2

PROJECT LOCATION MAP SHEET INDEX

AG001

AG002

AD101

AD201

AD202

A101

COVER SHEET

SITE LOGISTICS PLAN

DEMO FLOOR PLANS - ELEVATOR 3 (6514)

EXISTING CONDITIONS - ELEVATOR 3 (6514)

EXISTING CONDITIONS - ELEVATOR 4 (6512)

ENLARGED FLOOR PLANS - ELEVATOR 3 (6514)

ME000 ELECTRICAL / MECHANICAL GENERAL NOTES & SYMBOLS

ME100 ELECTRICAL / MECHANICAL OVERALL PLANS

PROJECT SITE

AG100 OVERALL FLOOR PLANS

AD102 DEMO FLOOR PLANS - ELEVATOR 4 (6512) / ELEVATOR 5 (6513)

AD203 EXISTING CONDITIONS - ELEVATOR 5 (6513)

A102 ENLARGED FLOOR PLANS - ELEVATOR 4 (6512) / ELEVATOR 5 (6513)

A103 ELEVATOR CAB DETAILS

MD101 ELECTRICAL / MECHANICAL DEMO PLANS ELEVATOR 3 (6514)

MD102 ELECTRICAL / MECHANICAL DEMO PLANS ELEVATOR 4 (6512) /

ELEVATOR 5 (6513)

ME101 ELECTRICAL / MECHANICAL PLANS ELEVATOR 3 (6514)

ME102 ELECTRICAL / MECHANICAL PLANS ELEVATOR 4 (6512) /

ELEVATOR 5 (6513)

A

19181716151413121110987654

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

P R

IN

T

E D

R

S

T

U

20 21 22 23 24 25

Sheet Name

Key Plan

19181716151413121110987654 20 21 22 23 24 25321

Sheet Number

Sheet Issue Date

OPN Project No.

Owner

All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by

OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc.

shall retain all common law, statutory and other reserved rights, including the copyright thereto.

© 2025 OPN Architects, Inc.

100 Court Ave., Suite 100

Des Moines, IA 50309

P: 515-309-0722 www.opnarchitects.com

DCI GROUP

220 SE 6TH STREET, SUITE 200

DES MOINES, IA 50309

Project

CONSTRUCTION MANAGER

LERCH BATES

7625 GOLDEN TRIANGLE DRIVE,

SUITE T

EDEN PRAIRIE, MN 55344

ELEVATOR CONSULTANT

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Mechanical Engineer

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Electrical Engineer

/1

/2

:3

:4

A M

AG002

SITE LOGISTICS PLAN

25832000

BID ISSUE SET 06/10/26

STATE HISTORICAL BUILDING ELEVATOR

REPLACEMENTS

STATE OF IOWA - 9440.01

600 E LOCUST STREET

DES MOINES, IA 50319

109 SE 13TH STREET

DES MOINES, IA 50319

FACILITY MAIN ENTRY

PROJECT ELEVATORS

CONTRACTOR TO UTILIZE STREET PARKING OR

THE CAPITOL COMPLEX GARAGE LOCATED HERE.

CONTRACTOR TO BE RESPONSIBLE FOR ALL

ASSOCIATED PARKING COSTS.

Revision Description Date

LOADING DOCK ENTRY

DUMPSTER LOCATION AT STREET CURB -

CONTRACTOR TO COORDINATE WITH CITY OF

DES MOINES FOR PERMITTING.

AHU

L1

AHU

L2

AHU

L3

AHU

L4

TRANSFORMER

ROOM

STAIR

ELECTRICAL

ROOM

C O R

ID

O

R MAIL

ROOM

CHEMICAL

STORAGE

PAINT

BOOTH

FUMIGATION

ROOM

METAL

SHOP

LOCKER

ROOM

LOCKER

ROOM

WOMENMEN

H A

LL

H A

LL

C H A S E

ELEV.

EQUIP.

CORRIDOR

ELEV.

EQUIP.

CLEANING

REGISTRAR

C O R R

ID

O R

WOOD

SHOP

WOOD

STORAGE

WOOD

STORAGE

DARK

RM.

WASH

RM.

PRINT

RM.

GRAPHICS

DEPT.

PUMP

RM.

STAIR CORRIDOR

AUDITORIUM

STAGE

STORAGE

ELEV.

LOBBY

ELEV.

EQUIP.

STORAGE

JANITOR

S T A

IR

MAINT.

OFFICE

JANITORS

STORAGE

MECH.

RM.

MECH.

RM.

CONSERVATION

LAB

CORRIDOR

ALTERNATE

STORAGE

ALTERNATE

STORAGE

C O R R

ID

O R

ELEV.

EQUIP.

S T A

IR

C O R R

ID

O R

FILM

DUPLICATION

PROCESSING

CAMERA

RM.

D A R K

R M

T2-LEA

LF

LG

DISC.T5-LG

LEA

DISC.

1 2 3 4 5 6 7 8 9 10 11 12 13 14

A

B

C

D

E

F

G

H

J

K

A

B

C

D

E

F

G

H

J

K

M A T C H

L

IN

E

M A T C H

L

IN

E

TSFS B

YARD

STORAGE

VEST.

TEL

EQUIP.

TRASH

RM.

STAIR

DOCK

DELIVERY

STAIR

EXHIBIT

SPACE

WOMEN

MEN

C O R R

ID

O R

AUDITORIUM P

R O

JE

C

TI

O N

VEST.

STORAGE

S T A

IR

COAT

RM.

SECURITY

ORIENTATION

VEST.

STORAGE

GIFT

SHOP

VEST.

PORTE

COCHERE

PORTE

COCHERE

VEST.

STAIR

LOBBY

LOBBY

NEWSPAPER

STORAGE

WORK

RM.

OFFICE

STAIR

C O R R

ID

O R

HALL

MEN

WOMEN

HALL

READING

RM.

ARCHIVAL

STORAGE

OFFICE

ARCHIVAL

MANUSCRIPT

PROCESSING

DISPLAY

PANTRY JAN.

STORAGE

ELEV.

#2

ELEV.

#5

LEA EA

HD LGALG

LCP-D LCP-GA

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

A

B

C

D

E

F

G

H

J

K

M A T C H

L

IN

E

M A T C H

L

IN

E

A

B

C

D

E

F

G

H

J

K

STAIR

#1

E L E V A T O R

STAIR

#3

ELEV.

#4

ELEV.

#5

ROOF

ACCESS

EXHIBIT

SPACE

MEN

WOMEN

GALLERY

C O R R

ID

O R

VEST.

ELEV.

LOBBY

MEN

WOMEN

LOBBY

ELEV.

LOBBY

VEST.

READING

ROOM

READING

ROOM

READING

ROOM

MICROFILM

READING

ROOM

CLOSED

HISTORICAL

COLLECTION

STACKS

STAIR

LOUNGE

LOCKER

HI

LCP-I

ELEVATOR

#1

ELEV.

#2

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

M A T C H

L

IN

E

M A T C H

L

IN

E

A

B

C

D

E

F

G

H

J

K

A

B

C

D

E

F

G

H

J

STAIR

#1

E L E V A T O R

STAIR

#3

ELEV.

#4

ELEV.

#5

CONFERENCE

ROOM

DIRECTOR

ASSISTANT

DIRECTOR

JAN.

OPEN

OFFICE

RECEPTION BOARD

ROOM

MEETING

ROOM

MEN

WOMEN

VEST.

PANTRY

LUNCH

ROOM

VENDING

LOBBY

B A

LC

O N Y

C O R R

ID

O R

STAIR

COOLING

TOWER

WORK

ROOM

CONFERENCE

ROOM

WOMEN MEN

RECEPTION

HISTORIC

PRESERVATION

STAIR

LN

SUB-PANEL

EAST WALL

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

M A T C H

L

IN

E

M A T C H

L

IN

E

A

B

C

D

E

F

G

H

J

K

A

B

C

D

E

F

G

H

J

ELEV.

LOBBY

MECH.

RM. 110

STAIR

M110

HF

T2-LI

LCP-F(ABOVE)

LI

D

E

F

MECH.

RM. M101

LOBBY

STAIR

M101

T7-LH/LHB

HC

LH

LHB

IW-1

IW-2

IW-3

IW-4

LCP-C

6 7 8 9 10

A

B

C

6.5

A.5

GENERAL NOTES

1. DIMENSIONS ARE MEASURED FACE-

OF-FINISH TO FACE-OF-FINISH OR

ROUGH MASONRY OPENING UNLESS

NOTED OTHERWISE - TYPICAL FOR ALL

DRAWINGS.

2. FIELD VERIFY ALL DIMENSIONS AND

EXISTING CONDITIONS - TYPICAL FOR

ALL DRAWINGS.

3. IN THE EVENT OF A DISCREPANCY

BETWEEN ARCHITECTURAL AND

CONSULTANT DRAWINGS, NOTIFY

ARCHITECT IMMEDIATELY PRIOR TO

COMMENCING WORK - TYPICAL FOR

ALL DRAWINGS.

4. ALL PENETRATIONS IN FIRE RATED

FLOORS AND WALLS MUST BE SEALED

WITH APPROPRIATE FIRESTOPPING

SYSTEM.

5. PATCH AND REPAIR EXISTING FLOOR

SLABS AND WALL SURFACES

DAMAGED FROM DEMOLITION.

AD101

P1

AD102

L2 A102

L2

A101

P1

AD101

H1 A101

H1

AD102

A2 A102

A1

AD101

P12

A101

P12

A102

L15

AD103

L2

AD101

H12 A101

H12

AD103

A2 A102

A15

AD101

A1

A101

A1

AD103

L15

AD102

L15

A

19181716151413121110987654

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

P R

IN

T

E D

R

S

T

U

20 21 22 23 24 25

Sheet Name

Key Plan

19181716151413121110987654 20 21 22 23 24 25321

Sheet Number

Sheet Issue Date

OPN Project No.

Owner

All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by

OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc.

shall retain all common law, statutory and other reserved rights, including the copyright thereto.

© 2025 OPN Architects, Inc.

100 Court Ave., Suite 100

Des Moines, IA 50309

P: 515-309-0722 www.opnarchitects.com

DCI GROUP

220 SE 6TH STREET, SUITE 200

DES MOINES, IA 50309

Project

CONSTRUCTION MANAGER

LERCH BATES

7625 GOLDEN TRIANGLE DRIVE,

SUITE T

EDEN PRAIRIE, MN 55344

ELEVATOR CONSULTANT

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Mechanical Engineer

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Electrical Engineer

/1

/2

:4

:3

A M

AG100

OVERALL PLANS

25832000

BID ISSUE SET 06/10/26

STATE HISTORICAL BUILDING ELEVATOR

REPLACEMENTS

STATE OF IOWA - 9440.01

600 E LOCUST STREET

DES MOINES, IA 50319

109 SE 13TH STREET

DES MOINES, IA 50319

Revision Description Date

N

1/32" = 1'-0" M1

OVERALL PLAN - BASEMENT

N

1/32" = 1'-0" D1

OVERALL PLAN - FIRST FLOOR

N

1/32" = 1'-0" M12

OVERALL PLAN - SECOND FLOOR

N

1/32" = 1'-0" D12

OVERALL PLAN - THIRD FLOOR

1/32" = 1'-0" A6

OVERALL PLAN - MEZZANINE - EAST

1/32" = 1'-0"

A1

OVERALL PLAN - MEZZANINE - WEST

ALL ELEVATOR WORK SHOULD

UTILIZE THE BASEMENT LEVEL FOR

ACCESS AND TRANSPORT OF

MATERIALS. EXISTING CONCRETE

FLOORS SHOULD BE MAINTAINED AND

PROPER PROTECTION (INCLUDING

WHEEL PROTECTION) SHOULD BE

USED TO PREVENT DAMAGE TO

FLOORS AND WALL SURFACES.

IF WORK IS REQUIRED AT OTHER

LEVELS, PROPER PROTECTION

SHOULD BE PROVIDED TO PROTECT

ALL FINISHES FROM DAMAGE.

ALL CORRIDORS ARE AVAILABLE FOR

USE BY CONTRACTORS AS REQUIRED

FOR CONSTRUCTION . CORRIDORS

CANNOT BE BLOCKED AT ANY TIME

AND MUST BE KEPT OPEN FOR

BUILDING USE AT ALL TIMES.

COORDINATE ANY MAJOR DELIVERIES

OR HEAVY USE TIME WITH BUILDING.

ELEV.

EQUIP.FILM

STAIR

HALL

DISPLAY

ELEV.

#5

ELEV.

LOBBY

LOUNGE

LOCKER

ELEV.

#2

ELEV.

#5

ELEV.

LOBBY

STAIR

HF

T2-LI

LCP-F(ABOVE)

LI

SEE ELEVATOR SPECIFICATIONS FOR

DEMO ITEMS AND FOR EXISTING

ELEVATOR ITEMS TO REMAIN.

DEMO EXISTING DOORS AND OPENERS -

SEE ELEVATOR SPEC.

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

EXISTING FIXTURES TO BE REMOVED

AND REPLACED. NEW FIXTURES TO

COVER EXISTING OPENINGS

COMPLETELY.

SEE ELEVATOR SPEC FOR DEMO

ITEMS AND FOR EXISTING

ELEVATOR ITEMS TO REMAIN.

MODIFY EXISTING DISCONNECT - SEE

ELECTRICAL.

EXISTING SHEET METAL ENCLOSURE

TO REMAIN. REPAIR AS REQUIRED

FROM ANY REMOVED CONDUITS TO

MAINTAIN PROPER SEPARATION

WITHIN ROOM.

REMOVE AND REPLACE EXISTING SHAFT

PROTECTION AS REQUIRED FOR NEW

INSTALL - SEE ELEVATOR SPEC FOR

SPECIFIC REQUIREMENTS.

A

19181716151413121110987654

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

P R

IN

T

E D

R

S

T

U

20 21 22 23 24 25

Sheet Name

Key Plan

19181716151413121110987654 20 21 22 23 24 25321

Sheet Number

Sheet Issue Date

OPN Project No.

Owner

All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by

OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc.

shall retain all common law, statutory and other reserved rights, including the copyright thereto.

© 2025 OPN Architects, Inc.

100 Court Ave., Suite 100

Des Moines, IA 50309

P: 515-309-0722 www.opnarchitects.com

DCI GROUP

220 SE 6TH STREET, SUITE 200

DES MOINES, IA 50309

Project

CONSTRUCTION MANAGER

LERCH BATES

7625 GOLDEN TRIANGLE DRIVE,

SUITE T

EDEN PRAIRIE, MN 55344

ELEVATOR CONSULTANT

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Mechanical Engineer

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Electrical Engineer

/1

/2

:4

:3

A M

AD101

ENLARGED DEMO PLANS -

ELEVATOR 3 (6514)

25832000

BID ISSUE SET 06/10/26

STATE HISTORICAL BUILDING ELEVATOR

REPLACEMENTS

STATE OF IOWA - 9440.01

600 E LOCUST STREET

DES MOINES, IA 50319

109 SE 13TH STREET

DES MOINES, IA 50319

Revision Description Date

1/4" = 1'-0" P1

DEMO ENLARGED PLAN - BASEMENT - ELEVATOR 3 (6514)

1/4" = 1'-0" H1

DEMO ENLARGED PLAN - FIRST FLOOR - ELEVATOR 3 (6514)

1/4" = 1'-0" P12

DEMO ENLARGED PLAN - SECOND FLOOR - ELEVATOR 3 (6514)

1/4" = 1'-0" H12

DEMO ENLARGED PLAN - THIRD FLOOR - ELEVATOR 3 (6514)

1/4" = 1'-0" A1

DEMO ENLARGED PLAN - MEZZANINE - EAST - ELEVATOR 3 (6514)

SEE ELEVATOR SPECIFICATIONS FOR DEMO

ITEMS AND FOR EXISTING ELEVATOR ITEMS

TO REMAIN.

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL ANY

DAMAGE TO FRAME AND REPAINT.

DEMO EXISTING DOORS AND OPENERS - SEE

ELEVATOR SPEC.

EXISTING FIXTURES TO BE REMOVED AND

REPLACED. NEW FIXTURES TO COVER

EXISTING OPENINGS COMPLETELY.

SEE ELEVATOR SPECIFICATIONS FOR DEMO

ITEMS AND FOR EXISTING ELEVATOR ITEMS

TO REMAIN.

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL ANY

DAMAGE TO FRAME AND REPAINT.

DEMO EXISTING DOORS AND OPENERS - SEE

ELEVATOR SPEC.

EXISTING FIXTURES TO BE REMOVED AND

REPLACED. NEW FIXTURES TO COVER

EXISTING OPENINGS COMPLETELY.

SEE ELEVATOR SPECIFICATIONS FOR DEMO

ITEMS AND FOR EXISTING ELEVATOR ITEMS

TO REMAIN.

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL ANY

DAMAGE TO FRAME AND REPAINT.

DEMO EXISTING DOORS AND OPENERS - SEE

ELEVATOR SPEC.

EXISTING FIXTURES TO BE REMOVED AND

REPLACED. NEW FIXTURES TO COVER

EXISTING OPENINGS COMPLETELY.

SEE ELEVATOR SPECIFICATIONS FOR DEMO

ITEMS AND FOR EXISTING ELEVATOR ITEMS

TO REMAIN.

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL ANY

DAMAGE TO FRAME AND REPAINT.

DEMO EXISTING DOORS AND OPENERS - SEE

ELEVATOR SPEC.

EXISTING FIXTURES TO BE REMOVED AND

REPLACED. NEW FIXTURES TO COVER

EXISTING OPENINGS COMPLETELY.

DOOR REMAIN LOCKED DURING

CONSTRUCTION AND NO ACCESS ALLOWED

TO CONTRACTORS.

LOCKER

ROOM

WOMEN

H A L L

ELEV.

EQUIP.

JANITOR

S T A

IR

MEN

C O R R

ID

O R

S T A

IR

ELEV.

#5

MECH.

RM. M101 STAIR

M101

T7-LH/LHB

HC

LH

LHB

IW-1

IW-2

IW-3

IW-4

LCP-C

SEE ELEVATOR SPEC FOR

DEMO ITEMS AND FOR

EXISTING ELEVATOR ITEMS TO

REMAIN.

SEE ELEVATOR SPEC FOR

DEMO ITEMS AND FOR

EXISTING ELEVATOR ITEMS TO

REMAIN.

DEMO DISCONNECT - SEE

ELECTRICAL

SEE ELEVATOR

SPECIFICATIONS FOR DEMO

ITEMS AND FOR EXISTING

ELEVATOR ITEMS TO REMAIN.

SEE ELEVATOR SPEC FOR

DEMO ITEMS AND FOR

EXISTING ELEVATOR ITEMS TO

REMAIN.

DEMO DISCONNECT - SEE

ELECTRICAL

DEMO EXISTING DOORS AND OPENERS -

SEE ELEVATOR SPEC.

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

EXISTING FIXTURES TO BE REMOVED

AND REPLACED. NEW FIXTURES TO

COVER EXISTING OPENINGS

COMPLETELY.

DEMO EXISTING DOORS AND OPENERS -

SEE ELEVATOR SPEC.

EXISTING FIXTURES TO BE REMOVED

AND REPLACED. NEW FIXTURES TO

COVER EXISTING OPENINGS

COMPLETELY.

AT EACH JAMB, REMOVE PLYWOOD AND

PROVIDE NEW STAINLESS STEEL PLATE

AND CORNER GUARDS AT EACH JAMB

(TO +4'-0" AFF) - BOTH SIDES.

SEE ELEVATOR

SPECIFICATIONS FOR DEMO

ITEMS AND FOR EXISTING

ELEVATOR ITEMS TO REMAIN.

EXISTING FIXTURES TO BE

REMOVED AND REPLACED. NEW

FIXTURES TO COVER EXISTING

OPENINGS COMPLETELY.

DEMO EXISTING DOORS AND

OPENERS - SEE ELEVATOR SPEC.

EXISTING PAINTED FRAMES TO

REMAIN - PROTECT IN PLACE.

CLEAN, PATCH / FILL ANY DAMAGE

TO FRAME AND REPAINT.

DEMO EXISTING DOORS AND

OPENERS - SEE ELEVATOR SPEC.

EXISTING FIXTURES TO BE

REMOVED AND REPLACED. NEW

FIXTURES TO COVER EXISTING

OPENINGS COMPLETELY.

SEE ELEVATOR

SPECIFICATIONS FOR DEMO

ITEMS AND FOR EXISTING

ELEVATOR ITEMS TO REMAIN.

EXISTING PAINTED FRAMES TO

REMAIN - PROTECT IN PLACE.

CLEAN, PATCH / FILL ANY DAMAGE

TO FRAME AND REPAINT.

DEMO EXISTING DOORS AND

OPENERS - SEE ELEVATOR SPEC.

EXISTING FIXTURES TO BE

REMOVED AND REPLACED. NEW

FIXTURES TO COVER EXISTING

OPENINGS COMPLETELY.

1/4" = 1'-0" L2

DEMO ENLARGED PLAN - BASEMENT - ELEVATOR 4 (6512) / ELEVATOR 5 (6513)

A

19181716151413121110987654

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

P R

IN

T

E D

R

S

T

U

20 21 22 23 24 25

Sheet Name

Key Plan

19181716151413121110987654 20 21 22 23 24 25321

Sheet Number

Sheet Issue Date

OPN Project No.

Owner

All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by

OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc.

shall retain all common law, statutory and other reserved rights, including the copyright thereto.

© 2025 OPN Architects, Inc.

100 Court Ave., Suite 100

Des Moines, IA 50309

P: 515-309-0722 www.opnarchitects.com

DCI GROUP

220 SE 6TH STREET, SUITE 200

DES MOINES, IA 50309

Project

CONSTRUCTION MANAGER

LERCH BATES

7625 GOLDEN TRIANGLE DRIVE,

SUITE T

EDEN PRAIRIE, MN 55344

ELEVATOR CONSULTANT

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Mechanical Engineer

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Electrical Engineer

/1

/2

:4

:3

A M

AD102

ENLARGED DEMO PLANS -

ELEVATOR 4 (6512) /

ELEVATOR 5 (6513)

25832000

BID ISSUE SET 06/10/26

STATE HISTORICAL BUILDING ELEVATOR

REPLACEMENTS

STATE OF IOWA - 9440.01

600 E LOCUST STREET

DES MOINES, IA 50319

109 SE 13TH STREET

DES MOINES, IA 50319

Revision Description Date

1/4" = 1'-0" A2

DEMO ENLARGED PLAN - FIRST FLOOR - ELEVATOR 4 (6512) / ELEVATOR 5 (6513)

1/4" = 1'-0" L15

DEMO ENLARGED PLAN - MEZZANINE - WEST - ELEVATOR 5 (6513)

E L E V A T O R

STAIR

#3

ELEV.

#4

C O R R

ID

O R

ELEV.

LOBBY

E L E V A T O R

STAIR

#3

ELEV.

#4

MEN

LOBBY

C O R R

ID

O R

MECH.

RM. M101 STAIR

M101

T7-LH/LHB

HC

LH

LHB

IW-1

IW-2

IW-3

IW-4

LCP-C

SEE ELEVATOR

SPECIFICATIONS FOR DEMO

ITEMS AND FOR EXISTING

ELEVATOR ITEMS TO REMAIN.

EXISTING PAINTED FRAMES TO

REMAIN - PROTECT IN PLACE.

CLEAN, PATCH / FILL ANY DAMAGE

TO FRAME AND REPAINT.

DEMO EXISTING DOORS AND

OPENERS - SEE ELEVATOR SPEC.

EXISTING FIXTURES TO BE

REMOVED AND REPLACED. NEW

FIXTURES TO COVER EXISTING

OPENINGS COMPLETELY.

DEMO EXISTING DOORS AND

OPENERS - SEE ELEVATOR SPEC.

EXISTING FIXTURES TO BE

REMOVED AND REPLACED. NEW

FIXTURES TO COVER EXISTING

OPENINGS COMPLETELY.

SEE ELEVATOR

SPECIFICATIONS FOR DEMO

ITEMS AND FOR EXISTING

ELEVATOR ITEMS TO REMAIN.

EXISTING PAINTED FRAMES TO

REMAIN - PROTECT IN PLACE.

CLEAN, PATCH / FILL ANY DAMAGE

TO FRAME AND REPAINT.

DEMO EXISTING DOORS AND

OPENERS - SEE ELEVATOR SPEC.

EXISTING FIXTURES TO BE

REMOVED AND REPLACED. NEW

FIXTURES TO COVER EXISTING

OPENINGS COMPLETELY.

DEMO EXISTING DOORS AND

OPENERS - SEE ELEVATOR SPEC.

EXISTING FIXTURES TO BE

REMOVED AND REPLACED. NEW

FIXTURES TO COVER EXISTING

OPENINGS COMPLETELY.

SEE ELEVATOR SPECIFICATIONS FOR

DEMO ITEMS AND FOR EXISTING

ELEVATOR ITEMS TO REMAIN.

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

DEMO EXISTING DOORS AND OPENERS -

SEE ELEVATOR SPEC.

EXISTING FIXTURES TO BE REMOVED AND

REPLACED. NEW FIXTURES TO COVER

EXISTING OPENINGS COMPLETELY.

1/4" = 1'-0" L2

DEMO ENLARGED PLAN - SECOND FLOOR - ELEVATOR 4 (6512) / ELEVATOR 5 (6513)

1/4" = 1'-0" A2

DEMO ENLARGED PLAN - THIRD FLOOR - ELEVATOR 4 (6512) / ELEVATOR 5 (6513)A

19181716151413121110987654

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

P R

IN

T

E D

R

S

T

U

20 21 22 23 24 25

Sheet Name

Key Plan

19181716151413121110987654 20 21 22 23 24 25321

Sheet Number

Sheet Issue Date

OPN Project No.

Owner

All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by

OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc.

shall retain all common law, statutory and other reserved rights, including the copyright thereto.

© 2025 OPN Architects, Inc.

100 Court Ave., Suite 100

Des Moines, IA 50309

P: 515-309-0722 www.opnarchitects.com

DCI GROUP

220 SE 6TH STREET, SUITE 200

DES MOINES, IA 50309

Project

CONSTRUCTION MANAGER

LERCH BATES

7625 GOLDEN TRIANGLE DRIVE,

SUITE T

EDEN PRAIRIE, MN 55344

ELEVATOR CONSULTANT

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Mechanical Engineer

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Electrical Engineer

/1

/2

:4

:3

A M

AD103

ENLARGED DEMO PLANS -

ELEVATOR 4 (6512) /

ELEVATOR 5 (6513)

25832000

BID ISSUE SET 06/10/26

STATE HISTORICAL BUILDING ELEVATOR

REPLACEMENTS

STATE OF IOWA - 9440.01

600 E LOCUST STREET

DES MOINES, IA 50319

109 SE 13TH STREET

DES MOINES, IA 50319

Revision Description Date

1/4" = 1'-0" L15

ENLARGED PLAN - MEZZANINE - WEST - ELEVATOR 5 (6513)

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

P R

IN

T

E D

R

S

T

U

20 21 22 23 24 25

Sheet Name

Key Plan

19181716151413121110987654 20 21 22 23 24 25321

Sheet Number

Sheet Issue Date

OPN Project No.

Owner

All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by

OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc.

shall retain all common law, statutory and other reserved rights, including the copyright thereto.

© 2025 OPN Architects, Inc.

100 Court Ave., Suite 100

Des Moines, IA 50309

P: 515-309-0722 www.opnarchitects.com

DCI GROUP

220 SE 6TH STREET, SUITE 200

DES MOINES, IA 50309

Project

CONSTRUCTION MANAGER

LERCH BATES

7625 GOLDEN TRIANGLE DRIVE,

SUITE T

EDEN PRAIRIE, MN 55344

ELEVATOR CONSULTANT

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Mechanical Engineer

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Electrical Engineer

/1

/2

:3

:3

A M

AD201

EXISTING CONDITIONS -

ELEVATOR 3 (6514)

25832000

BID ISSUE SET 06/10/26

STATE HISTORICAL BUILDING ELEVATOR

REPLACEMENTS

STATE OF IOWA - 9440.01

600 E LOCUST STREET

DES MOINES, IA 50319

109 SE 13TH STREET

DES MOINES, IA 50319

IMAGE 3

IMAGE 2

IMAGE 1

IMAGE 4

IMAGE 5

IMAGE 6

IMAGE 7

IMAGE 8

IMAGE 9

IMAGE 10

IMAGE 11

IMAGE 12

REMOVE AND REPLACE EXISTING

SIGNAGE AND CONTROLS. REQUIRED

ELEVATOR SIGNAGE TO BE INTEGRAL TO

CONTROLS. NEW FIXTURES SHOULD

COMPLETELY COVER OLD BOXES /

PENETRATIONS.

PROTECT ALL EXISTING HALLWAY

FINISHES DURING CONSTRUCTION.

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

REMOVE AND REPLACE EXISTING

ELEVATOR CEILING AND LIGHTING - SEE

ELEVATOR SPEC AND DRAWINGS FOR

SPECIFIC REQUIREMENTS.

REMOVE AND REPLACE EXISTING

ELEVATOR FINISHES - SEE ELEVATOR

SPEC AND ELEVATOR ELEVATION

DRAWINGS FOR SPECIFIC

REQUIREMENTS.

Revision Description Date

EXISTING MECHANICAL ROOM IS

CONDITIONED / VENTED - SEE MECHANICAL.

REMOVE AND REPLACE EXISTING

ELEVATOR MACHINERY - SEE

ELEVATOR SPEC FOR SPECIFIC

REQUIREMENTS.

PROVIDE NEW PREFINISHED ELEVATOR

DOORS AND OPENERS - SEE ELEVATOR

SPEC. FINISH TO MATCH EXISTING.

FLOOR SIGNAGE TO BE REMOVED AND

REPLACED - SEE ELEVATOR SPEC.

REMOVE AND REPLACE EXISTING

ELEVATOR FLOORING - SEE ELEVATOR

SPEC FOR INSTALLATION REQUIREMENTS

AND ELEVATOR ELEVATION DRAWINGS

FOR MATERIALS.

PREP EXISTING FLOOR AS REQUIRED FOR

NEW PAINT FINISH - SEE SPECS.

PROVIDE NEW ELEVATOR DOORS AND

OPENERS - SEE ELEVATOR SPEC.

REMOVE AND REPLACE EXISTING

SIGNAGE AND CONTROLS. REQUIRED

ELEVATOR SIGNAGE TO BE INTEGRAL TO

CONTROLS. NEW FIXTURES SHOULD

COMPLETELY COVER OLD BOXES /

PENETRATIONS.

PROTECT ALL EXISTING HALLWAY

FINISHES DURING CONSTRUCTION.

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

PROVIDE NEW PREFINISHED ELEVATOR

DOORS AND OPENERS - SEE ELEVATOR

SPEC. FINISH TO MATCH EXISTING.

FLOOR SIGNAGE TO BE REMOVED AND

REPLACED.

EXISTING SIGNAGE TO REMAIN.

REMOVE AND REPLACE EXISTING

SIGNAGE AND CONTROLS.

REMOVE AND REPLACE EXISTING

SIGNAGE AND CONTROLS. REQUIRED

ELEVATOR SIGNAGE TO BE INTEGRAL TO

CONTROLS. NEW FIXTURES SHOULD

COMPLETELY COVER OLD BOXES /

PENETRATIONS.

PROTECT ALL EXISTING HALLWAY

FINISHES DURING CONSTRUCTION.

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

PROVIDE NEW PREFINISHED ELEVATOR

DOORS AND OPENERS - SEE ELEVATOR

SPEC. FINISH TO MATCH EXISTING.

FLOOR SIGNAGE TO BE REMOVED AND

REPLACED.

EXISTING SIGNAGE TO REMAIN.

REMOVE AND REPLACE EXISTING

SIGNAGE AND CONTROLS. REQUIRED

ELEVATOR SIGNAGE TO BE INTEGRAL TO

CONTROLS. NEW FIXTURES SHOULD

COMPLETELY COVER OLD BOXES /

PENETRATIONS.

PROTECT ALL EXISTING HALLWAY

FINISHES DURING CONSTRUCTION.

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

PROVIDE NEW PREFINISHED ELEVATOR

DOORS AND OPENERS - SEE ELEVATOR

SPEC. FINISH TO MATCH EXISTING.

FLOOR SIGNAGE TO BE REMOVED AND

REPLACED.

EXISTING SIGNAGE TO REMAIN.

REMOVE AND REPLACE EXISTING

SIGNAGE AND CONTROLS. REQUIRED

ELEVATOR SIGNAGE TO BE INTEGRAL TO

CONTROLS. NEW FIXTURES SHOULD

COMPLETELY COVER OLD BOXES /

PENETRATIONS.

PROTECT ALL EXISTING HALLWAY

FINISHES DURING CONSTRUCTION.

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

PROVIDE NEW PREFINISHED ELEVATOR

DOORS AND OPENERS - SEE ELEVATOR

SPEC. FINISH TO MATCH EXISTING.

FLOOR SIGNAGE TO BE REMOVED AND

REPLACED.

EXISTING SIGNAGE TO REMAIN.

RELOCATE BUILDING MAP AS REQUIRED FOR

NEW ELEVATOR CONTROLS.

ALL EXISTING FINISHES TO BE REPLACED

IN ELEVATOR. SEE ELEVATOR SPEC AND

DRAWINGS FOR NEW FINISHES.

REMOVE AND REPLACE EXISTING ELEVATOR

CONTROL PANEL - SEE ELEVATOR SPEC FOR

SPECIFIC REQUIREMENTS.

PROVIDE BRAILLE AND MATCH ALL LABELING

ON ALL BUTTONS, INCLUDING SIGNAGE BELOW.

ALL BRAILLE AND SIGNAGE PLATES TO BE

AFFIXED PLATES TO ELEVATOR CONTROL

PANEL FOR ABILITY TO REPLACE IN FUTURE.

ALL OTHER SIGNAGE TO BE ENGRAVED ON

CONTROL PANEL.

ALL EXISTING FINISHES TO BE REPLACED

IN ELEVATOR. SEE ELEVATOR SPEC AND

DRAWINGS FOR NEW FINISHES.

ELEVATOR TO BE PROVIDED / COORDINATED

WITH A COMBINATION CARD ACCESS / PIN

CODE FOR ACCESS - SEE ELECTRICAL.

EXISTING SHAFT AND RAILS TO REMAIN -

SEE ELEVATOR SPEC FOR ELEVATOR

REQUIREMENTS.

EXISTING COUNTERWEIGHTS - SEE

ELEVATOR SPEC FOR ELEVATOR

REQUIREMENTS.

SEE ELECTRICAL FOR SHAFT DETECTION

REQUIREMENTS.

EXISTING VENT SHAFT TO REMAIN. NO

CHANGE.

PROVIDE NEW COMPLIANT SHAFT LIGHTING -

SEE ELECTRICAL.

GOVERNOR WITH REMOTE RESET - SEE

ELEVATOR SPEC FOR REQUIREMENTS.

EXISTING SHAFT AND RAILS TO REMAIN -

SEE ELEVATOR SPEC FOR ELEVATOR

REQUIREMENTS.

REMOVE AND REPLACE EXISTING ELEVATOR

MACHINERY - SEE ELEVATOR SPEC FOR

SPECIFIC REQUIREMENTS.

REMOVE AND REPLACE ELEVATOR PIT

LADDER. NEW LADDER TO BE IN COMPLIANCE

WITH ALL CURRENT APPLICABLE CODES.

COORDINATE EXACT LOCATION WITH

ELEVATOR PROVIDER.

EXISTING PIT IS DRY AND FREE OF SIGNS

OF WATER INTRUSION. THERE IS AN

EXISTING COVERED PIT THAT IS TO REMAIN

AS IS. PAINT COVER WITH FLOOR.

PIT FLOOR TO BE CLEANED AND PREPPED

FOR NEW PAINT FINISH - SEE ELEVATOR

SPEC.

REMOVE AND REPLACE EXISTING ELEVATOR

MACHINERY - SEE ELEVATOR SPEC FOR

SPECIFIC REQUIREMENTS.

PROVIDE NEW COMPLIANT SHAFT LIGHTING -

SEE ELECTRICAL.

EXISTING SHAFT AND RAILS TO REMAIN -

SEE ELEVATOR SPEC FOR ELEVATOR

REQUIREMENTS.

PIT FLOOR TO BE CLEANED AND PREPPED

FOR NEW PAINT FINISH - SEE ELEVATOR

SPEC.

REMOVE AND REPLACE EXISTING ELEVATOR

CONTROLLER - SEE ELEVATOR SPEC FOR

SPECIFIC REQUIREMENTS.

REMOVE AND REPLACE EXISTING ELEVATOR

CONTROLLER - SEE ELEVATOR SPEC FOR

SPECIFIC REQUIREMENTS.

PREP EXISTING FLOOR AS REQUIRED FOR

NEW PAINT FINISH - SEE SPECS.

REMOVE AND REPLACE EXISTING SHAFT

PROTECTION AS REQUIRED FOR NEW

INSTALL - SEE ELEVATOR SPEC FOR

SPECIFIC REQUIREMENTS.

SEE ELECTRICAL FOR ALL RELAYS TO

REMAIN OR BE REUSED. SEE ELECTRICAL

/ TELECOM FOR REQUIREMENTS.

PROVIDE NEW ELEVATOR DOORS AND

OPENERS - SEE ELEVATOR SPEC.

EXISTING SIGNAGE TO REMAIN.

POLISH AND CLEAN ALL SILLS TO

REMAIN - TYPICAL ALL ELEVATORS.

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

P R

IN

T

E D

R

S

T

U

20 21 22 23 24 25

Sheet Name

Key Plan

19181716151413121110987654 20 21 22 23 24 25321

Sheet Number

Sheet Issue Date

OPN Project No.

Owner

All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by

OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc.

shall retain all common law, statutory and other reserved rights, including the copyright thereto.

© 2025 OPN Architects, Inc.

100 Court Ave., Suite 100

Des Moines, IA 50309

P: 515-309-0722 www.opnarchitects.com

DCI GROUP

220 SE 6TH STREET, SUITE 200

DES MOINES, IA 50309

Project

CONSTRUCTION MANAGER

LERCH BATES

7625 GOLDEN TRIANGLE DRIVE,

SUITE T

EDEN PRAIRIE, MN 55344

ELEVATOR CONSULTANT

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Mechanical Engineer

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Electrical Engineer

/1

/2

:3

:4

A M

AD202

EXISTING CONDITIONS -

ELEVATOR 4 (6512)

25832000

BID ISSUE SET 06/10/26

STATE HISTORICAL BUILDING ELEVATOR

REPLACEMENTS

STATE OF IOWA - 9440.01

600 E LOCUST STREET

DES MOINES, IA 50319

109 SE 13TH STREET

DES MOINES, IA 50319

IMAGE 13

IMAGE 14

IMAGE 15

IMAGE 16

IMAGE 17

IMAGE 18

IMAGE 19

Revision Description Date

IMAGE 20

IMAGE 21

IMAGE 22

IMAGE 23

IMAGE 24

REMOVE AND REPLACE EXISTING

SIGNAGE AND CONTROLS. REQUIRED

ELEVATOR SIGNAGE TO BE INTEGRAL TO

CONTROLS. NEW FIXTURES SHOULD

COMPLETELY COVER OLD BOXES /

PENETRATIONS.

PROTECT ALL EXISTING HALLWAY

FINISHES DURING CONSTRUCTION.

EXISTING PAINTED OPENING TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

REMOVE ALL EXISTING SIGNAGE

COMPLETE AND PROVIDE NEW CODE

COMPLIANT SIGNAGE.

PROVIDE NEW PREFINISHED ELEVATOR

DOORS AND OPENERS - SEE ELEVATOR

SPEC. FINISH TO MATCH EXISTING.

PROVIDE NEW ELEVATOR DOORS AND

OPENERS - SEE ELEVATOR SPEC.

EXISTING BI-PARTING DOORS TO REMAIN.

PROTECT DURING CONSTRUCTION.

PROTECT ALL EXISTING HALLWAY

FINISHES DURING CONSTRUCTION.

EXISTING PAINTED OPENING TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

PROVIDE NEW PREFINISHED ELEVATOR

DOORS AND OPENERS - SEE ELEVATOR

SPEC. FINISH TO MATCH EXISTING.

COORDINATE ALL REQUIRED SIGNAGE

LOCATIONS WITH ARCHITECT / OWNER

PRIOR TO INSTALLATION.

PROTECT ALL EXISTING HALLWAY

FINISHES DURING CONSTRUCTION.

EXISTING ELEVATOR LIGHTING TO BE

REMOVED AND NEW SURFACE MOUNTED

FIXTURES TO BE PROVIDED. SEE

ELEVATOR RCP.

EXISTING ELEVATOR FLOOR TO REMAIN.

CLEAN AND POLISH EXISTING FLOOR - SEE

ELEVATOR SPECIFICATIONS.

EXISTING WALL PANELS TO BE MAINTAINED -

PREP WALLS AND PROVIDE NEW

ELECTROSTATIC PAINT FINISH.

WALLS TO MATCH EXISTING COLOR.

CEILING TO BE WHITE.

EXISTING SHAFT AND RAILS TO REMAIN -

SEE ELEVATOR SPEC FOR ELEVATOR

REQUIREMENTS.

EXISTING COUNTERWEIGHTS - SEE

ELEVATOR SPEC FOR ELEVATOR

REQUIREMENTS.

SEE ELECTRICAL FOR SHAFT DETECTION

REQUIREMENTS.

EXISTING VENT SHAFT TO REMAIN - NO

WORK.

PROVIDE NEW COMPLIANT SHAFT LIGHTING -

SEE ELECTRICAL.

EXISTING SHAFT AND RAILS TO REMAIN -

SEE ELEVATOR SPEC FOR ELEVATOR

REQUIREMENTS.

REMOVE AND REPLACE ELEVATOR PIT

LADDER. NEW LADDER TO BE IN

COMPLIANCE WITH ALL CURRENT

APPLICABLE CODES. COORDINATE EXACT

LOCATION WITH ELEVATOR PROVIDER.

PIT FLOOR TO BE CLEANED AND PREPPED

FOR NEW PAINT FINISH - SEE ELEVATOR

SPEC.

REMOVE AND REPLACE EXISTING ELEVATOR

MACHINERY - SEE ELEVATOR SPEC FOR

SPECIFIC REQUIREMENTS.

PROVIDE NEW COMPLIANT SHAFT LIGHTING -

SEE ELECTRICAL.

PROVIDE NEW ELEVATOR DOORS AND

OPENERS - SEE ELEVATOR SPEC.

AT EACH JAMB, REMOVE PLYWOOD AND

PROVIDE NEW STAINLESS STEEL PLATE

AND CORNER GUARDS AT EACH JAMB (TO

+4'-0" AFF).

REMOVE AND REPLACE EXISTING

SIGNAGE AND CONTROLS. REQUIRED

ELEVATOR SIGNAGE TO BE INTEGRAL TO

CONTROLS. NEW FIXTURES SHOULD

COMPLETELY COVER OLD BOXES /

PENETRATIONS.

PROTECT ALL EXISTING HALLWAY

FINISHES DURING CONSTRUCTION.

EXISTING PAINTED OPENING TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

PROVIDE NEW PREFINISHED ELEVATOR

DOORS AND OPENERS - SEE ELEVATOR

SPEC. FINISH TO MATCH EXISTING.

AT EACH JAMB, REMOVE PLYWOOD AND

PROVIDE NEW STAINLESS STEEL PLATE

AND CORNER GUARDS AT EACH JAMB (TO

+4'-0" AFF).

EXISTING MAGNETIC HOLDS TO REMAIN.

PROTECT DURING CONSTRUCTION.

EXISTING BI-PARTING DOORS TO REMAIN.

PROTECT DURING CONSTRUCTION.

COORDINATE NEW CONTROL FIXTURE TO

PROVIDE OPERATION IN EXISTING

LOCATION. ALLOW ROOM ON NEW

CONTROL PLATE FOR CARD ACCESS

CONTROLLER TO REPLACE USER KEY

CONTROL.

REMOVE AND REPLACE EXISTING

SIGNAGE AND CONTROLS. REQUIRED

ELEVATOR SIGNAGE TO BE INTEGRAL TO

CONTROLS. NEW FIXTURES SHOULD

COMPLETELY COVER OLD BOXES /

PENETRATIONS.

PROTECT ALL EXISTING HALLWAY

FINISHES DURING CONSTRUCTION.

EXISTING PAINTED OPENING TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

AT EACH JAMB, REMOVE PLYWOOD AND

PROVIDE NEW STAINLESS STEEL PLATE

AND CORNER GUARDS AT EACH JAMB (TO

+4'-0" AFF).

EXISTING WALL PANELS TO BE MAINTAINED -

PREP WALLS AND PROVIDE NEW

ELECTROSTATIC PAINT FINISH.

PROVIDE NEW ELEVATOR CONTROL

PANEL - SEE ELEVATOR SPEC.

PIT FLOOR TO BE CLEANED AND PREPPED

FOR NEW PAINT FINISH - SEE ELEVATOR

SPEC.

REMOVE AND REPLACE EXISTING SHAFT

PROTECTION AS REQUIRED FOR NEW

INSTALL - SEE ELEVATOR SPEC FOR

SPECIFIC REQUIREMENTS.

EXISTING MACHINE ROOM IS CONDITIONED /

VENTED - SEE MECHANICAL.

EXISTING CEILING HAS NON-ELEVATOR

RELATED UTILITIES RUNNING THROUGH

THE SPACE. A NEW HARD LID CEILING

WILL BE REQUIRED TO BE ADDED TO THE

SPACE.

REMOVE AND REPLACE EXISTING

ELEVATOR MACHINERY - SEE

ELEVATOR SPEC FOR SPECIFIC

REQUIREMENTS.

REMOVE AND REPLACE EXISTING ELEVATOR

CONTROLLER - SEE ELEVATOR SPEC FOR

SPECIFIC REQUIREMENTS.

PREP EXISTING FLOOR AS REQUIRED FOR

NEW PAINT FINISH - SEE SPECS.

REMOVE AND REPLACE EXISTING SHAFT

PROTECTION AS REQUIRED FOR NEW

INSTALL - SEE ELEVATOR SPEC FOR

SPECIFIC REQUIREMENTS.

SEE ELECTRICAL FOR ALL RELAYS TO

REMAIN OR BE REUSED. SEE ELECTRICAL

/ TELECOM FOR REQUIREMENTS.

SEE ELECTRICAL FOR DISCONNECTS /

CONTROLLERS TO REMAIN OR BE

REUSED. SEE ELECTRICAL / TELECOM

FOR REQUIREMENTS.

EXISTING CEILING HAS NON-ELEVATOR

RELATED UTILITIES RUNNING THROUGH

THE SPACE. A NEW HARD LID CEILING

WILL BE REQUIRED TO BE ADDED TO THE

SPACE.

EXISTING DETECTION AND RELAYS WILL

NEED TO BE RELOCATED AS REQUIRED

FOR NEW HARD LID CEILING, SEE

ELECTRICAL FOR REQUIREMENTS.

REMOVE AND PROVIDE NEW MACHINE

ROOM LIGHTING - SEE ELECTRICAL.

ELEVATOR PROVIDER TO PROVIDE NEW

SILL TRIMS AS REQUIRED TO REDUCE GAP

AT EACH FLOOR TRANSITION - SEE

ELEVATOR SPEC.

RUN NEW STAINLESS STEEL PLATE FROM

INSIDE ELEVATOR JAMB EQUAL WITH

WALL TO CORNER, THEN TURN CORNER

AND RUN ON CORRIDOR WALL OVER TO

ADJACENT DOOR FRAME.

RUN NEW STAINLESS STEEL PLATE FROM

INSIDE ELEVATOR JAMB EQUAL WITH

WALL TO CORNER, THEN TURN CORNER

AND RUN ON CORRIDOR WALL OVER TO

ADJACENT DOOR FRAME.

RUN NEW STAINLESS STEEL PLATE FROM

INSIDE ELEVATOR JAMB EQUAL WITH

WALL TO CORNER, THEN TURN CORNER

AND RUN TO WALL AS SHOWN.

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

P R

IN

T

E D

R

S

T

U

20 21 22 23 24 25

Sheet Name

Key Plan

19181716151413121110987654 20 21 22 23 24 25321

Sheet Number

Sheet Issue Date

OPN Project No.

Owner

All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by

OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc.

shall retain all common law, statutory and other reserved rights, including the copyright thereto.

© 2025 OPN Architects, Inc.

100 Court Ave., Suite 100

Des Moines, IA 50309

P: 515-309-0722 www.opnarchitects.com

DCI GROUP

220 SE 6TH STREET, SUITE 200

DES MOINES, IA 50309

Project

CONSTRUCTION MANAGER

LERCH BATES

7625 GOLDEN TRIANGLE DRIVE,

SUITE T

EDEN PRAIRIE, MN 55344

ELEVATOR CONSULTANT

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Mechanical Engineer

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Electrical Engineer

/1

/2

:3

:4

A M

AD203

EXISTING CONDITIONS -

ELEVATOR 5 (6513)

25832000

BID ISSUE SET 06/10/26

STATE HISTORICAL BUILDING ELEVATOR

REPLACEMENTS

STATE OF IOWA - 9440.01

600 E LOCUST STREET

DES MOINES, IA 50319

109 SE 13TH STREET

DES MOINES, IA 50319

IMAGE 25

IMAGE 26

IMAGE 27

IMAGE 28

IMAGE 29

IMAGE 30

IMAGE 31

IMAGE 32

IMAGE 33

IMAGE 34

IMAGE 35

IMAGE 36

Revision Description Date

REMOVE AND REPLACE EXISTING

SIGNAGE AND CONTROLS. REQUIRED

ELEVATOR SIGNAGE TO BE INTEGRAL TO

CONTROLS. NEW FIXTURES SHOULD

COMPLETELY COVER OLD BOXES /

PENETRATIONS.

PROTECT ALL EXISTING HALLWAY

FINISHES DURING CONSTRUCTION.

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

EXISTING MECHANICAL ROOM IS

CONDITIONED / VENTED - SEE MECHANICAL.

REMOVE AND REPLACE EXISTING

ELEVATOR MACHINERY - SEE

ELEVATOR SPEC FOR SPECIFIC

REQUIREMENTS.

PROVIDE NEW PREFINISHED ELEVATOR

DOORS AND OPENERS - SEE ELEVATOR

SPEC. FINISH TO MATCH EXISTING.

FLOOR SIGNAGE TO BE REMOVED AND

REPLACED.

PREP EXISTING FLOOR AS REQUIRED FOR

NEW PAINT FINISH - SEE SPECS.

REMOVE AND REPLACE EXISTING

SIGNAGE AND CONTROLS. REQUIRED

ELEVATOR SIGNAGE TO BE INTEGRAL TO

CONTROLS. NEW FIXTURES SHOULD

COMPLETELY COVER OLD BOXES /

PENETRATIONS.

PROTECT ALL EXISTING HALLWAY

FINISHES DURING CONSTRUCTION.

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

PROVIDE NEW PREFINISHED ELEVATOR

DOORS AND OPENERS - SEE ELEVATOR

SPEC. FINISH TO MATCH EXISTING.

FLOOR SIGNAGE TO BE REMOVED AND

REPLACED.

EXISTING SIGNAGE TO REMAIN.

REMOVE AND REPLACE EXISTING

SIGNAGE AND CONTROLS. REQUIRED

ELEVATOR SIGNAGE TO BE INTEGRAL TO

CONTROLS. NEW FIXTURES SHOULD

COMPLETELY COVER OLD BOXES /

PENETRATIONS.

PROTECT ALL EXISTING HALLWAY

FINISHES DURING CONSTRUCTION.

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

PROVIDE NEW PREFINISHED ELEVATOR

DOORS AND OPENERS - SEE ELEVATOR

SPEC. FINISH TO MATCH EXISTING.

FLOOR SIGNAGE TO BE REMOVED AND

REPLACED.

EXISTING SIGNAGE TO REMAIN.

REMOVE AND REPLACE EXISTING

SIGNAGE AND CONTROLS. REQUIRED

ELEVATOR SIGNAGE TO BE INTEGRAL TO

CONTROLS. NEW FIXTURES SHOULD

COMPLETELY COVER OLD BOXES /

PENETRATIONS.

PROTECT ALL EXISTING HALLWAY

FINISHES DURING CONSTRUCTION.

EXISTING PAINTED FRAMES TO REMAIN -

PROTECT IN PLACE. CLEAN, PATCH / FILL

ANY DAMAGE TO FRAME AND REPAINT.

PROVIDE NEW PREFINISHED ELEVATOR

DOORS AND OPENERS - SEE ELEVATOR

SPEC. FINISH TO MATCH EXISTING.

FLOOR SIGNAGE TO BE REMOVED AND

REPLACED.

EXISTING SIGNAGE TO REMAIN.

EXISTING SHAFT AND RAILS TO REMAIN -

SEE ELEVATOR SPEC FOR ELEVATOR

REQUIREMENTS.

EXISTING COUNTERWEIGHTS - SEE

ELEVATOR SPEC FOR ELEVATOR

REQUIREMENTS.

SEE ELECTRICAL FOR SHAFT DETECTION

REQUIREMENTS.

EXISTING VENT SHAFT TO REMAIN - NO

WORK.

PROVIDE NEW COMPLIANT SHAFT LIGHTING -

SEE ELECTRICAL.

GOVERNOR WITH EXTERIOR ROOF ACCESS

FOR RESET - SEE ELEVATOR SPEC FOR

REQUIREMENTS.

EXISTING SHAFT AND RAILS TO REMAIN -

SEE ELEVATOR SPEC FOR ELEVATOR

REQUIREMENTS.

REMOVE AND REPLACE EXISTING ELEVATOR

MACHINERY - SEE ELEVATOR SPEC FOR

SPECIFIC REQUIREMENTS.

REMOVE AND REPLACE ELEVATOR PIT

LADDER TO REMAIN. LADDER TO BE IN

COMPLIANCE WITH ALL CURRENT

APPLICABLE CODES.

PIT FLOOR TO BE CLEANED AND PREPPED

FOR NEW PAINT FINISH - SEE ELEVATOR

SPEC.

REMOVE AND REPLACE EXISTING ELEVATOR

MACHINERY - SEE ELEVATOR SPEC FOR

SPECIFIC REQUIREMENTS.

PROVIDE NEW COMPLIANT SHAFT LIGHTING -

SEE ELECTRICAL.

REMOVE AND REPLACE EXISTING ELEVATOR

CONTROLLER - SEE ELEVATOR SPEC FOR

SPECIFIC REQUIREMENTS.

REMOVE AND REPLACE EXISTING ELEVATOR

CONTROLLER - SEE ELEVATOR SPEC FOR

SPECIFIC REQUIREMENTS.

PREP EXISTING FLOOR AS REQUIRED FOR

NEW PAINT FINISH - SEE SPECS.

REMOVE AND REPLACE EXISTING SHAFT

PROTECTION AS REQUIRED FOR NEW

INSTALL - SEE ELEVATOR SPEC FOR

SPECIFIC REQUIREMENTS.

SEE ELECTRICAL FOR ALL RELAYS TO

REMAIN OR BE REUSED. SEE ELECTRICAL

/ TELECOM FOR REQUIREMENTS.

PROVIDE NEW ELEVATOR DOORS AND

OPENERS - SEE ELEVATOR SPEC.

ALL EXISTING FINISHES TO BE REPLACED

IN ELEVATOR. SEE ELEVATOR SPEC AND

DRAWINGS FOR NEW FINISHES.

REMOVE AND REPLACE EXISTING ELEVATOR

CONTROL PANEL - SEE ELEVATOR SPEC FOR

SPECIFIC REQUIREMENTS.

PROVIDE BRAILLE AND MATCH ALL LABELING

ON ALL BUTTONS, INCLUDING SIGNAGE BELOW.

ALL BRAILLE AND SIGNAGE PLATES TO BE

AFFIXED PLATES TO ELEVATOR CONTROL

PANEL FOR ABILITY TO REPLACE IN FUTURE.

ALL OTHER SIGNAGE TO BE ENGRAVED ON

CONTROL PANEL.

ALL EXISTING FINISHES TO BE REPLACED

IN ELEVATOR. SEE ELEVATOR SPEC AND

DRAWINGS FOR NEW FINISHES.

ELEVATOR TO BE PROVIDED / COORDINATED

WITH A COMBINATION CARD ACCESS / PIN

CODE FOR ACCESS - SEE ELECTRICAL.

REMOVE AND REPLACE EXISTING

ELEVATOR CEILING AND LIGHTING - SEE

ELEVATOR SPEC AND DRAWINGS FOR

SPECIFIC REQUIREMENTS.

REMOVE AND REPLACE EXISTING

ELEVATOR FINISHES - SEE ELEVATOR

SPEC AND ELEVATOR ELEVATION

DRAWINGS FOR SPECIFIC

REQUIREMENTS.

REMOVE AND REPLACE EXISTING

ELEVATOR FLOORING - SEE ELEVATOR

SPEC FOR INSTALLATION REQUIREMENTS

AND ELEVATOR ELEVATION DRAWINGS

FOR MATERIALS.

PROVIDE NEW ELEVATOR DOORS AND

OPENERS - SEE ELEVATOR SPEC.

REMOVE AND REPLACE EXISTING

ELEVATOR MACHINERY - SEE ELEVATOR

SPEC FOR SPECIFIC REQUIREMENTS.

ROOF ACCESS LADDER TO

GOVERNOR ACCESS DOORS.

EXTERIOR ACCESS DOOR TO GOVERNOR

REST FOR ELEVATORS 4 AND 5.

ROOF ACCESS LADDER TO

GOVERNOR ACCESS DOORS.

EXTERIOR ACCESS DOOR TO GOVERNOR

REST FOR ELEVATORS 4 AND 5.

POLISH AND CLEAN ALL SILLS TO

REMAIN - TYPICAL ALL ELEVATORS.

STAIR

HALL

DISPLAY

ELEV.

#5

ELEV.

LOBBY

LOUNGE

LOCKER

ELEV.

#2

ELEV.

#5

ELEV.

LOBBY

STAIR

HF

T2-LI

LCP-F(ABOVE)

LI

SEE ELEVATOR SPEC FOR FULL SCOPE OF WORK

PREP, CLEAN, PATCH / FILL AND DAMAGE TO

FRAME AND REPAINT.

PROVIDE NEW ELEVATOR DOORS AND OPENERS -

SEE ELEVATOR SPEC.

PROVIDE TEMPORARY WOOD SHEATHING

PARTITION WALL WITH DOOR. ENCLOSURES TO BE

COORDINATED WITH FACILITY AND LIMITED TO

ONLY WHEN WORK OCCURRING THIS SIDE.

COORDINATE TIMING WITH FACILITY AND

CONSTRUCTION MANAGER.

PROTECT IN PLACE ALL EXISTING BUILDING

FINISHES DURING CONSTRUCTION. PROVIDE

TEMPORARY ENCLOSURES AS REQUIRED DURING

CONSTRUCTION TO PROTECT WORK AND

HOISTWAYS.

NEW ELEVATOR CONTROLLER - COORDINATE

FINAL LOCATION WITHIN ROOM WITH ALL OTHER

EQUIPMENT - SEE ELEVATOR SPECIFICATIONS.

NEW ELEVATOR TRACTION MACHINE -

COORDINATE FINAL LOCATION WITHIN ROOM WITH

ALL OTHER EQUIPMENT - SEE ELEVATOR

SPECIFICATIONS.

NEW ELECTRICAL DISCONNECT - SEE ELECTRICAL.

COORDINATE FINAL LOCATION WITH ELEVATOR

EQUIPMENT.

A

19181716151413121110987654

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

P R

IN

T

E D

R

S

T

U

20 21 22 23 24 25

Sheet Name

Key Plan

19181716151413121110987654 20 21 22 23 24 25321

Sheet Number

Sheet Issue Date

OPN Project No.

Owner

All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by

OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc.

shall retain all common law, statutory and other reserved rights, including the copyright thereto.

© 2025 OPN Architects, Inc.

100 Court Ave., Suite 100

Des Moines, IA 50309

P: 515-309-0722 www.opnarchitects.com

DCI GROUP

220 SE 6TH STREET, SUITE 200

DES MOINES, IA 50309

Project

CONSTRUCTION MANAGER

LERCH BATES

7625 GOLDEN TRIANGLE DRIVE,

SUITE T

EDEN PRAIRIE, MN 55344

ELEVATOR CONSULTANT

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Mechanical Engineer

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Electrical Engineer

/1

/2

:4

:3

A M

A101

ENLARGED FLOOR PLANS -

ELEVATOR 3 (6514)

25832000

BID ISSUE SET 06/10/26

STATE HISTORICAL BUILDING ELEVATOR

REPLACEMENTS

STATE OF IOWA - 9440.01

600 E LOCUST STREET

DES MOINES, IA 50319

109 SE 13TH STREET

DES MOINES, IA 50319

1/4" = 1'-0" P1

ENLARGED PLAN - BASEMENT - ELEVATOR 3 (6514)

Revision Description Date

1/4" = 1'-0" H1

ENLARGED PLAN - FIRST FLOOR - ELEVATOR 3 (6514)

1/4" = 1'-0" P12

ENLARGED PLAN - SECOND FLOOR - ELEVATOR 3 (6514)

1/4" = 1'-0" H12

ENLARGED PLAN - THIRD FLOOR - ELEVATOR 3 (6514)

1/4" = 1'-0" A1

ENLARGED PLAN - MEZZANINE - EAST - ELEVATOR 3 (6514)

PREP CLEAN, PATCH / FILL AND DAMAGE TO FRAME

AND REPAINT.

PROVIDE NEW ELEVATOR DOORS AND OPENERS -

SEE ELEVATOR SPEC.

SEE ELEVATOR SPEC FOR FULL SCOPE OF WORK.

PROTECT IN PLACE ALL EXISTING BUILDING

FINISHES DURING CONSTRUCTION. PROVIDE

TEMPORARY ENCLOSURES AS REQUIRED DURING

CONSTRUCTION TO PROTECT WORK AND

HOISTWAYS.

PREP CLEAN, PATCH / FILL AND DAMAGE TO FRAME

AND REPAINT.

PROVIDE NEW ELEVATOR DOORS AND OPENERS -

SEE ELEVATOR SPEC.

SEE ELEVATOR SPEC FOR FULL SCOPE OF WORK.

PROTECT IN PLACE ALL EXISTING BUILDING

FINISHES DURING CONSTRUCTION. PROVIDE

TEMPORARY ENCLOSURES AS REQUIRED DURING

CONSTRUCTION TO PROTECT WORK AND

HOISTWAYS.

PREP CLEAN, PATCH / FILL AND DAMAGE TO FRAME

AND REPAINT.

PROVIDE NEW ELEVATOR DOORS AND OPENERS -

SEE ELEVATOR SPEC.

SEE ELEVATOR SPEC FOR FULL SCOPE OF WORK.

PROTECT IN PLACE ALL EXISTING BUILDING

FINISHES DURING CONSTRUCTION. PROVIDE

TEMPORARY ENCLOSURES AS REQUIRED DURING

CONSTRUCTION TO PROTECT WORK AND

HOISTWAYS.

PREP CLEAN, PATCH / FILL AND DAMAGE TO FRAME

AND REPAINT.

PROVIDE NEW ELEVATOR DOORS AND OPENERS -

SEE ELEVATOR SPEC.

SEE ELEVATOR SPEC FOR FULL SCOPE OF WORK.

PROTECT IN PLACE ALL EXISTING BUILDING

FINISHES DURING CONSTRUCTION. PROVIDE

TEMPORARY ENCLOSURES AS REQUIRED DURING

CONSTRUCTION TO PROTECT WORK AND

HOISTWAYS.

PROVIDE TEMPORARY WOOD SHEATHING

PARTITION WALL WITH DOOR. ENCLOSURES TO BE

COORDINATED WITH FACILITY AND LIMITED TO

ONLY WHEN WORK OCCURRING THIS SIDE.

COORDINATE TIMING WITH FACILITY AND

CONSTRUCTION MANAGER.

LOCKER

ROOM

WOMEN

H A L L

ELEV.

EQUIP.

JANITOR

S T A

IR

MEN

C O R R

ID

O R

S T A

IR

ELEV.

#5

E L E V A T O R

STAIR

#3

ELEV.

#4

C O R R

ID

O R

ELEV.

LOBBY

E L E V A T O R

STAIR

#3

ELEV.

#4

MEN

LOBBY

C O R R

ID

O R

GENERAL NOTES

1. DIMENSIONS ARE MEASURED FACE-

OF-FINISH TO FACE-OF-FINISH OR

ROUGH MASONRY OPENING UNLESS

NOTED OTHERWISE - TYPICAL FOR ALL

DRAWINGS.

2. FIELD VERIFY ALL DIMENSIONS AND

EXISTING CONDITIONS - TYPICAL FOR

ALL DRAWINGS.

3. IN THE EVENT OF A DISCREPANCY

BETWEEN ARCHITECTURAL AND

CONSULTANT DRAWINGS, NOTIFY

ARCHITECT IMMEDIATELY PRIOR TO

COMMENCING WORK - TYPICAL FOR

ALL DRAWINGS.

4. ALL PENETRATIONS IN FIRE RATED

FLOORS AND WALLS MUST BE SEALED

WITH APPROPRIATE FIRESTOPPING

SYSTEM.

5. PATCH AND REPAIR EXISTING FLOOR

SLABS AND WALL SURFACES

DAMAGED FROM DEMOLITION.

A

19181716151413121110987654

B

C

D

E

F

G

H

J

K

L

M

N

P

Q

P R

IN

T

E D

R

S

T

U

20 21 22 23 24 25

Sheet Name

Key Plan

19181716151413121110987654 20 21 22 23 24 25321

Sheet Number

Sheet Issue Date

OPN Project No.

Owner

All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by

OPN Architects, Inc. as instruments of service shall remain the property of OPN Architects, Inc. OPN Architects, Inc.

shall retain all common law, statutory and other reserved rights, including the copyright thereto.

© 2025 OPN Architects, Inc.

100 Court Ave., Suite 100

Des Moines, IA 50309

P: 515-309-0722 www.opnarchitects.com

DCI GROUP

220 SE 6TH STREET, SUITE 200

DES MOINES, IA 50309

Project

CONSTRUCTION MANAGER

LERCH BATES

7625 GOLDEN TRIANGLE DRIVE,

SUITE T

EDEN PRAIRIE, MN 55344

ELEVATOR CONSULTANT

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Mechanical Engineer

KCL ENGINEERING

300 4TH STREET

WEST DES MOINES, IA 50317

Electrical Engineer

/1

/2

:4

:3

A M

A102

ENLARGED FLOOR PLANS -

ELEVATOR 4 (6512) /

ELEVATOR 5 (6513)

25832000

BID ISSUE SET 06/10/26

STATE HISTORICAL BUILDING ELEVATOR

REPLACEMENTS

STATE OF IOWA - 9440.01

600 E LOCUST STREET

DES MOINES, IA 50319

109 SE 13TH STREET

DES MOINES, IA 50319

Revision Description Date

1/4" = 1'-0" L2

ENLARGED PLANS - BASEMENT - ELEVATOR 4 (6512) / ELEVATOR 5 (6513)

1/4" = 1'-0" A1

ENLARGED PLAN - FIRST FLOOR - ELEVATOR 4 (6512) / ELEVATOR 5 (6513)

1/4" = 1'-0" L15

ENLARGED PLAN - SECOND FLOOR - ELEVATOR 4 (6512) / ELEVATOR 5 (6513)

1/4" = 1'-0" A15

ENLARGED PLAN - THIRD FLOOR - ELEVATOR 4 (6512) / ELEVATOR 5 (6513)

PREP CLEAN, PATCH / FILL AND DAMAGE TO FRAME

AND REPAINT.

PROVIDE NEW ELEVATOR

DOORS AND OPENERS -

SEE ELEVATOR SPEC.

SEE ELEVATOR SPEC FOR FULL SCOPE OF WORK.

PROTECT IN PLACE ALL EXISTING BUILDING

FINISHES DURING CONSTRUCTION. PROVIDE

TEMPORARY ENCLOSURES AS REQUIRED DURING

CONSTRUCTION TO PROTECT WORK AND

HOISTWAYS.

NEW ELECTRICAL DISCONNECT - SEE ELECTRICAL.

COORDINATE FINAL LOCATION WITH ELEVATOR

EQUIPMENT.

NEW ELEVATOR CONTROLLER - COORDINATE FINAL

LOCATION WITHIN ROOM WITH ALL OTHER

EQUIPMENT - SEE ELEVATOR SPECIFICATIONS.

NEW ELEVATOR TRACTION MACHINE - COORDINATE

FINAL LOCATION WITHIN ROOM WITH ALL OTHER

EQUIPMENT - SEE ELEVATOR SPECIFICATIONS.

PROVIDE TEMPORARY WOOD SHEATHING

PARTITION WALL WITH DOOR. ENCLOSURES TO BE

COORDINATED WITH FACILITY AND LIMITED TO

ONLY WHEN WORK OCCURRING THIS SIDE.

COORDINATE TIMING WITH FACILITY AND

CONSTRUCTION MANAGER.

NEW ELEVATOR CONTROLLER -

COORDINATE FINAL LOCATION WITHIN

ROOM WITH ALL OTHER EQUIPMENT -

SEE ELEVATOR SPECIFICATIONS.

NEW ELEVATOR TRACTION MACHINE -

COORDINATE FINAL LOCATION WITHIN

ROOM WITH ALL OTHER EQUIPMENT -

SEE ELEVATOR SPECIFICATIONS.

NEW ELECTRICAL DISCONNECT - SEE

ELECTRICAL. COORDINATE FINAL

LOCATION WITH ELEVATOR EQUIPMENT.

PROVIDE NEW GYPSUM BOARD

CEILING WITHIN SPACE TO SEPARATE

EXISTING UTILITIES FROM THE

MACHINE ROOM. PLACE CEILING AS

HIGH IN SPACE AS POSSIBLE.

PREP CLEAN, PATCH / FILL AND DAMAGE TO FRAME

AND REPAINT.

PROVIDE NEW ELEVATOR

DOORS AND OPENERS -

SEE ELEVATOR SPEC.

SEE ELEVATOR SPEC FOR FULL SCOPE OF WORK.

PROTECT IN PLACE ALL EXISTING BUILDING

FINISHES DURING CONSTRUCTION. PROVIDE

TEMPORARY ENCLOSURES AS REQUIRED DURING

CONSTRUCTION TO PROTECT WORK AND

HOISTWAYS.

PROVIDE NEW ELEVATOR DOORS AND

OPENERS - SEE ELEVATOR SPEC.

PROVIDE NEW ELEVATOR DOORS AND

OPENERS - SEE ELEVATOR SPEC.

PREP CLEAN, PATCH / FILL AND DAMAGE

TO FRAME AND REPAINT.

PROVIDE NEW ELEVATOR

DOORS AND OPENERS -

SEE ELEVATOR SPEC.

SEE ELEVATOR SPEC FOR FULL

SCOPE OF WORK.

PROTECT IN PLACE ALL EXISTING BUILDING

FINISHES DURING CONSTRUCTION. PROVIDE

TEMPORARY ENCLOSURES AS REQUIRED

DURING CONSTRUCTION TO PROTECT WORK

AND HOISTWAYS.

PROVIDE NEW ELEVATOR DOORS AND

OPENERS - SEE ELEVATOR SPEC.

PROVIDE TEMPORARY WOOD SHEATHING

PARTITION WALL WITH DOOR. ENCLOSURES

TO BE COORDINATED WITH FACILITY AND

LIMITED TO ONLY WHEN WORK OCCURRING

THIS SIDE. COORDINATE TIMING WITH

FACILITY AND CONSTRUCTION MANAGER.

PREP CLEAN, PATCH / FILL AND DAMAGE

TO FRAME AND REPAINT.

PROVIDE NEW ELEVATOR

DOORS AND OPENERS -

SEE ELEVATOR SPEC.

SEE ELEVATOR SPEC FOR FULL

SCOPE OF WORK.

PROTECT IN PLACE ALL EXISTING BUILDING

FINISHES DURING CONSTRUCTION. PROVIDE

TEMPORARY ENCLOSURES AS REQUIRED

DURING CONSTRUCTION TO PROTECT

WORK AND HOISTWAYS.

PROVIDE NEW ELEVATOR DOORS AND

OPENERS - SEE ELEVATOR SPEC.

AT EACH JAMB, REMOVE PLYWOOD AND PROVIDE

NEW STAINLESS STEEL PLATE AND CORNER

GUARDS AT EACH JAMB (TO +4'-0" AFF).

RUN NEW STAINLESS STEEL PLATE FROM INSIDE

ELEVATOR JAMB EQUAL WITH WALL TO CORNER,

THEN TURN CORNER AND RUN ON CORRIDOR WALL

TO EXTENT AS SHOWN.

BACK & SIDE WALLS

EXISTING ELEVATOR

FLOORING TO REMAIN -

CLEAN AND POLISH -

SEE ELEVATOR SPEC.

ELEVATOR CONTROL

PANEL (ANOD ST.STL.)

EXISTING ELEVATOR

WALL PANELS -

ELECTROSTATIC PAINT

(MATCH EXISTING COLOR)

LINEAR RECESSED

LIGHT FIXTURE

EXISTING ELEVATOR CEILING

PANELS - ELECTROSTATIC

PAINT (WHITE)

RAISED PANEL TYPE B - WILSONART

COMPACT LAMINATE PANEL.

COLOR: AMBER CHERRY (7919K)

FINISH: 60

PROVIDE WITH FINISHED EDGES.

WALL PANEL TYPE A - BRUSHED ST. STL.

METAL WITH 5WL TEXTURE. PANEL TO

BE SET TIGHT CAB SHELL TO MAINTAIN

MAXIMUM CLEARANCE IN CAB.

B

A

B

ANODIZED ST. STL. ELEVATOR SHELL

ANODIZED ST. STL. BUMPER - ON

STAND OFFS.

PROVIDE VENTS AT BASE OF CAB

BACK & SIDE WALLS

PROVIDE HOOK BUTTONS AT EACH

CAB AND 2 SET OF PROTECTION

PADS - ALL WALLS TYPICAL

ANODIZED ST. STL.

DROP CEILING - SEE RCP

ANO…

This is the start of the file's text. The full file is on GovTribe.