This document is a Material Approval Submittal form for a federal contract opportunity. It appears to be related to an irrigation system for a project at Patrick Space Force Base. The form includes details on irrigation requirements such as pipe sizes, pump specifications, and valve quantities. It also includes diagrams and performance charts for the proposed irrigation equipment. The submittal appears to be a resubmittal, with a previous submittal number of 06. Key details include the contract number FA252123C0020, the project number SXHT 23-1019, and the contractor Matt Conneen of the project management firm. The form indicates that the contracting officer is Rosita Serrano. Based on the submittal content, the primary products or services required appear to be irrigation system installation and maintenance at the Patrick Space Force Base athletic fields.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
For Evaluation and Action
(YYYYMMDD)
(YYYYMMDD)
(YYYYMMDD)
(YYYYMMDD)
(YYYYMMDD)
Form Approved OMB No 9000-0062 Expires May 31, 2005
MATERIAL APPROVAL SUBMITTAL
(See Instructions on Reverse)
Public reporting burden for this collection of information is estimated to average 20 minutes per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden to the Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington VA 22202-4302, and to the Office of Management and Budget, Paperwork Reduction Project OMB No 9000-0062, Washington DC 20503. Please DO NOT RETURN your form to either of these addresses. Send your completed form to: SAF/AQCP, 1060 Air Force Pentagon, Washington DC 20330-1060.
TO: (Contracting Officer) FROM: (Contractor) DATE
CONTRACT NUMBER SUBMISSION NUMBER SUBMITTAL
NEW RESUBMITTAL
PREVIOUS SUBMISSION NUMBER PROJECT NUMBER
TO BE COMPLETED BY CONTRACTOR FOR GOVERNMENT USE ONLY
ITEM SPECIFICATION SECTION/ DESCRIPTION OF MATERIAL AP-
PROVED
DISAP-
PROVED
SEE
REVERSE INITIAL
BY COMPLETING THIS FORM, THE UNDERSIGNED CONTRACTOR CERTIFIES THAT
THE MATERIAL COMPLIES WITH ALL SPECIFICATIONS OF SUBJECT CONTRACT.
DATE TYPE OR PRINT NAME AND TITLE SIGNATURE
FOR GOVERNMENT USE ONLY
TO: (Base Civil Engineering Officer)
DATE TYPE OR PRINT NAME AND GRADE SIGNATURE
TO: (AF Contracting Office)
RECOMMEND APPROVAL DISAPPROVAL AS INDICATED ABOVE AND SUBJECT TO ANY APPLICABLE COMMENTS ON THE REVERSE
DATE TYPE OR PRINT NAME AND GRADE SIGNATURE
TO: (Contractor)
DISAPROVED AS INDICATED ABOVE AND SUBJECT TO ANY APPLICABLE COMMENTS ON THE REVERSE SIDE. REQUEST
APPROVED
RESUBMITTAL ON DISAPPROVED ITEMS WITHIN DAYS OF DATE SHOWN BELOW.
DATE TYPE OR PRINT NAME AND GRADE SIGNATURE
AF IMT 3000, 20030901, V1 PREVIOUS EDITION IS OBSOLETE.
NO. PARA NO./DRAWING NO. (Include Type, Model Number, Catalog Number, Mfg., etc.)
COMMENTS
(Number to correspond with applicable Item Number on reverse)
INSTRUCTIONS TO CONTRACTORS
1. The term "material" is defined as articles, supplies, raw materials, equipment, parts, components, and end items that are to be incorporated into the work required by the contract.
2. This form is to be used by contractors for submitting Shop Drawings, Equipment Data, Manufacturer's Literature and Certificates and samples of Materials to the Government for approval in accordance with the provisions of this contract. Unless otherwise specified, it is to be prepared in 4 copies, signed, and provided to the contracting officer with appropriate attachments.
3. Item(s) to be approved will be clearly tabbed or identified. Data pertaining to item(s) to be approved will be clearly identified or tabbed, particularly where documents are voluminous, in order to properly evaluate the materials or articles to be incorporated in the work. Each attachment will be numbered to correspond with the item number shown on the face of this form.
4. Requests submitted shall be numbered consecutively, by contract, in the space entitled "Submission No.". This number, in addition to the Contract No., will be used to identify each Material Approval Submittal. Resubmissions will be indicated in the appropriate block and the insertion of previous submission number and data in addition to a new submission number. A single submission should be used for all work of a section of the specifications, but in NO instance should the submission include work for more than one (1) contract. Submittals requiring priority handling will be submitted by separate submittal using the form and so marked across the face of the form.
5. This Material Approval Submittal is not valid unless it is signed by the contracting officer. This approval is required as called for by the contracting officer under the terms of this contract.
AF IMT 3000, 20030901, V1 (REVERSE)
MConneen Text Box Locations, pipe sizes, and quantity of zones will be adjusted as needed after pump station flow and pressures are confirm.
MConneen Callout Please confirm if infield clay will need irrigation.
STA-RITE® PRo-Storm™ DS3 Series Self-priming centrifugal
The Pro-Storm™ Series* of cast iron sprinklers offers superior unmatched performance, available in 1 HP through 2-1/2 HP models.
The Pro-Storm models offer “single-body-fill” priming to 25-foot lifts, in less than 5 minutes!
The Pro-Storm models exceed the strict safety requirements of Underwriters Laboratories UL778, and CSA. Required by many state and local codes.
The Pro-Storm models are completely interchangeable with the original
Sta-Rite® DS2 Series models, saving costly plumbing “change-out” dollars and installation headaches!
*Single- and three-phase available
APPLICATIONS
Residential irrigation pump…can be safely operated by timer or other automatic device Contractors…for dewatering excavation, water transfer and supply Agriculture...seed bed and plot irrigation, stock watering Industrial...sump drainage, marine pumping, liquid transfer and supply operations
Noryl® is a registered trademark of General Electric Co. All other brands or product names are trademarks or registered trademarks of Pentair Ltd.
UL778/CSA108
NOTE: All single-phase motors shipped from the factory set at 230 volt.
SPECIFICATIONS
Body and Seal Plate: Close-grained cast iron Impeller: Noryl®
Diffuser: Reinforced polypropylene Shaft: One-piece threaded 300 grade stainless steel Base: Steel, 10 gauge Motor: 2-compartment
FEATURES
Rugged Construction: Close-grained cast iron body, specially treated for corrosion resistance.
Noryl Impeller: Precision-molded for perfect balance…ultra-smooth for highest performance and efficiency.
Precision-Molded Diffuser: Pump primes faster, handles more air, with multi-port, precision-molded, reinforced polypropylene diffuser.
High Head Models: Deliver up to 145' of head with capacities to 95 GPM.
Easy Serviceability: Normal wear ing parts are easily accessible for service and replacement, without disturbing piping or mounting.
Motor Windings: Superior insulation materials protect against excessive moisture and contaminants…ensures prolonged motor life.
Balanced Rotor: Diecast under high pressures for uniform performance and greater efficiency, dynamically balanced.
Drain Port: Provided for easy winterizing.ORDERINg INFORMATION
High Head Catalog Number HP Voltage Phase
Pipe Tapping Sizes Approx.
Wt. Lbs.Suction Discharge
DS3HE 1 115/230 1 2" 1-1/2" 52
DS3HE3 1 208-230/460 3 2" 1-1/2" 52
DS3HF 1-1/2 115/230 1 2" 1-1/2" 58
DS3HF3 1-1/2 208-230/460 3 2" 1-1/2" 58
DS3HG 2 115/230 1 2" 2" 83
DS3HG3 2 208-230/460 3 2" 2" 83
DS3HHG 2-1/2 115/230 1 2" 2" 85
DS3HHG3 2-1/2 208-230/460 3 2" 2" 85
1 s5563ws
Line
15 FT.
MIN.
MIN.
MIN.
MIN.
25 FT.
15 FT. 15 FT.
CAPACITY GALLONS PER MINUTE
T O
T A
L H
E A
D
IN
F E
E T
CAPACITY LITERS PER MINUTE
T O
T A
L H
E A
D
IN
M E
T E
R S
0 20 40 60 80 100 120
DS3HF
DS3HE
DS3HG
DS3HHG
RECOMMENDED OPERATING RANGE
10 30 50 70 90 110
0 50 150 250 350 450100 200 300 400
25 FT.
25 FT.
PUMP PERFORMANCE
NOTE: Dotted lines indicate performance reduction at high suction lift.
Tested and rated in accordance with Water Systems Council Standards.
NOTE: Pumps installed with a Pro-Source® tank require a 100 PSI relief valve. Pumps installed with a conventional tank require a 75 PSI relief valve.
Relief valve must be capable of relieving entire flow of pump at relief pressure.
PUMP PERFORMANCE (CapaCity in Gallons per Minute) Catalog Number HP
Discharge Pressure Suction Lift in Feet PSI Feet Head 5' 10' 15' 20' 25'
DS3HE 1
20 46.2 48 45 40 37 33 30 69.3 33 30 26 22 16 40 92.4 15 10 — — —
DS3HF 1-1/2
20 46.2 64 62 60 57 54 30 69.3 53 50 46 42 37 40 92.4 35 30 25 19 —
DS3HG 2
20 46.2 72 70 67 65 62 30 69.3 60 58 54 51 47 40 92.4 45 42 37 30 27 50 115.5 23 16 — — —
DS3HHG 2-1/2
20 46.2 83 80 77 74 71 30 69.3 70 67 63 60 55 40 92.4 56 52 48 40 35 50 115.5 36 28 20 — —
2 s5563ws
OUTLINE DIMENSIONS
R O
T A
T
IO
N
C
2" NPT
"A" NPT
6.07
(4) O.38 HOLES
10.00
1.12
7.89
8.00 4.06
3.82
11.58
13.08
6.75
1.64 3.64
7.50
.94 8.40
B
1.50
3.77
Catalog Number
A
NPT B C
DS3HE 1-1/2" NPT 17.04 15.60
DS3HE3 1-1/2" NPT 15.45 14.07
DS3HF 1-1/2" NPT 18.10 16.66
DS3HF3 1-1/2" NPT 15.95 14.48
DS3HG 2" NPT 18.54 17.10
DS3HG3 2" NPT 16.95 15.48
DS3HHG 2" NPT 18.85 17.41
DS3HHG3 2" NPT 17.69 16.23
Dimensions (in inches) are for estimating purposes only.
3 s5563ws
OWNER’S MANUAL
Self-Priming Centrifugal Pump
3621 0714 ASB“DS3” Series
Installation/Operation/Parts For further operating, installation, or maintenance assistance:
Call 888-782-7483
© 2014 Pentair Ltd. All Rights Reserved. S536 (07/07/14)
293 WRIGHT STREET, DELAVAN, WI 53115 WWW.STA-RITE.COM
PH: 888-782-7483
Safety 2
READ AND FOLLOW
SAFETY INSTRUCTIONS!
This is the safety alert symbol. When you see this symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury.
warns about hazards that will cause serious personal injury, death or major property damage if ignored.
warns about hazards that can cause serious personal injury, death or major property damage if ignored.
warns about hazards that will or can cause minor personal injury or property damage if ignored.
The label NOTICE indicates special instructions which are important but not related to hazards.
Carefully read and follow all safety instructions in this manual and on pump.
Keep safety labels in good condition.
Replace missing or damaged safety labels.
California Proposition 65 Warning
This product and related accessories contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
GENERAL SAFETY
Do not touch an operating motor. Modern motors can operate at high temperatures. To avoid burns when servicing pump, allow it to cool for 20 minutes after shut-down before handling.
Pump is designed as a lawn sprinkler only. To avoid heat built-up, over pressure hazard and possible injury, do not use in a pressure tank (domestic water) system. Do not use as a booster pump; pressurized suction may cause pump body to explode.
Do not allow pump or piping system to freeze. Freezing can damage pump and pipe, may lead to injury from equipment failure and will void warranty.
Pump water only with this pump.
Periodically inspect pump and system components.
Wear safety glasses at all times when working on pumps.
Keep work area clean, uncluttered and properly lighted;
store properly all unused tools and equipment.
Keep visitors at a safe distance from the work areas.
Make workshops childproof; use padlocks and master switches; remove starter keys.
WARNING
Hazardous pressure!
Install pressure relief valve in discharge pipe.
Release all pressure on system before working on any component.
WARNING
Hazardous voltage.
Can shock, burn, or cause death.
Ground pump before connecting to power supply.
Wire motor for correct voltage.
See “Electri cal” section of this manual and motor nameplate.
Ground motor before connecting to power supply.
Meet National Electri cal Code, Canadian Elec tri cal Code, and local codes for all wiring.
Follow wiring instructions in this manual when connecting motor to power lines.
ELECTRICAL SAFETY
Table of Contents 3
Thank you for purchasing a top quality, factory tested pump.
Page
Safety
Warranty
Installation ........................................................................................................4-5
Electrical
Operation
Maintenance ...................................................................................................8-10
Troubleshooting
Repair Parts
Limited Warranty STA-RITE warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below.
Product Warranty Period
Water Systems Products — jet pumps, small centrifugal pumps, submersible pumps and related accessories whichever occurs first:
12 months from date of original installation, or 18 months from date of manufacture
Pro-Source™ Composite Tanks 5 years from date of original installation
Pro-Source™ Steel Pressure Tanks 5 years from date of original installation
Pro-Source™ Epoxy-Lined Tanks 3 years from date of original installation
Sump/Sewage/Effluent Products 12 months from date of original installation, or 18 months from date of manufacture
Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is void.
Your only remedy, and STA-RITE’s only duty, is that STA-RITE repair or replace defective products (at STA-RITE’s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable.
STA-RITE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION EXPRESSLY PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state.
This Limited Warranty is effective June 1, 2011 and replaces all undated warranties and warranties dated before June 1, 2011.
STA-RITE INDUSTRIES
293 Wright Street • Delavan, WI U.S.A. 53115
Phone: 1-888-782-7483 • Fax: 1-800-426-9446 • Web Site: sta-rite.com
Installation 4
BEFORE YOU INSTALL YOUR PUMP
NOTICE: Well must not be more than 20’ depth to water.
1. Long runs and many fittings increase friction and reduce flow. Locate pump as close to well as possible: use as few elbows and fittings as possible.
2. Be sure well is clear of sand. Sand will plug the pump and void the warranty.
3. Protect pump and all piping from freezing. Freezing will split pipe, damage pump and void the warranty. Check locally for frost protection requirements (usually pipe must be 12” below frost line and pump must be insulated).
4. Be sure all pipes and foot valve are clean and in good shape.
5. No air pockets in suction pipe.
6. No leaks in suction pipe. Use PTFE pipe thread sealant tape to seal pipe joints.
7. Unions installed near pump and well will aid in servicing. Leave room use wrenches.
8. Pump body may explode if used as a booster pump.
DO NOT use in a booster appli cation.
WELL PIPE INSTALLATION
NOTICE: Use the installation method below which matches your well type.
CASED WELL INSTALLATION
1. Inspect foot valve to be sure it works freely. Inspect strainer to be sure it is clean.
2. Connect foot valve and strainer to the first length of suction pipe and lower pipe into well. Add sections of pipe as needed, using PTFE pipe thread sealant tape on male threads. Be sure that all suction pipe is leakproof or pump will lose prime and fail to pump. Install foot valve 10 to 20 feet below the lowest level to which water will drop while pump is operating (pumping water level). Your well driller can furnish this in formation.
3. To prevent sand and sediment from entering the pumping system, the foot valve/strainer should be at least 5 feet above the bottom of the well.
4. When the proper depth is reached, install a sanitary well seal over the pipe and in the well casing. Tighten the bolts to seal the casing.
5. When using a foot valve, a priming tee and plug as shown in Figure 1 are recommended.
DUG WELL INSTALLATION
Same as cased well installation.
DRIVEN POINT INSTALLATION
1. Connect the suction pipe to the drive point as illustrated in Figure 2.
Keep horizontal pipe run as short as possible. Use PTFE pip thread sealant tape on male pipe threads. Multiple well points may be necessary to provide sufficient water to pump.
2. Install a check valve in horizontal pipe. Flow arrow on check valve must point toward pump.
Suction pipe
Foot Valve
Priming plug
Priming tee
Standing water level (pump off)
Drawdown water level (pump on)
10-20' (3-6 m)
20' (6 m) max.
At least 5 feet (1.5 m)
828 0993
Check valve
Steel drive pipe
Drive coupling
Driven point
745 0993
Figure 1: Cased/Dug Well Installation
Figure 2: Driven Point Installation
Installation 5
HORIZONTAL PIPING FROM WELL TO PUMP
1. Never install a suction pipe that is smaller than the suction port of the pump.
2. To aid priming on well point installations, install a line check valve as shown in Figure 2. Be sure check valve flow arrow points toward pump.
DISCHARGE PIPE SIZES
1. If increasing discharge pipe size, install reducer in pump discharge port. Do not increase pipe size by stages.
2. When the pump is set away from the points of water use, the discharge pipe size should be increased to reduce pressure losses caused by friction.
• Up to 100’ run: Same size as pump discharge port.
• 100’ to 300’ run: Increase one pipe size.
• 300’ to 600’ run: Increase two pipe sizes.
LAWN SPRINKLING APPLICATION
This pump is designed for lawn sprinkling. It is de signed to deliver plenty of water at full sprinkler pres sure. It can pump from a pond, cistern or well points.
Pump discharge can be divided to supply two (2) or more sprinkler systems. A suggested multiple dis charge to service is shown in Figure 3.
Do not use in a pressure tank or booster pump application.
PUMP INSTALLATION
NOTICE: Use only PTFE pipe thread sealant tape for making all threaded connections to the pump itself. Do not use pipe joint compounds on plastic pumps: they can react with the plastic in the pump components.
Make sure that all pipe joints in the suction pipe are air tight as well as water tight. If the suction pipe can suck air, the pump will not be able to pull water from the well.
1. Bolt pump to solid, level foundation.
2. Support all piping connected to the pump.
3. Wrap 1-1/2 to two layers of PTFE pipe thread sealant tape clockwise (as you face end of pipe) on all male threads being attached to pump.
4. Tighten joints hand tight plus 1-1/2 turns. Do not overtighten.
NOTICE: Install pump as close to well head as poss ible. Long piping runs and many fittings create friction and reduce flow.
NOTICE: For long horizontal pipe runs, install a priming tee between check valve and well head as shown in Figure 1. For driven point installations, install a check valve as shown in Figure 2. Be sure check valve flow arrow points toward pump.
Use schedule 80 or iron pipe. See “Well Pipe In stalla tion” for more information.
Figure 3: Multiple Discharge
Figure 4: Bolt Pump Down
Figure 5: Independently Support All Piping Attached to Pump
6894 0814
6895 0814
6896 0814
Electrical 6
Connection diagram for dual voltage, single-phase motors. Your dual-voltage motor’s terminal board (under the motor end cover) will match one of the diagrams below. Follow that diagram if necesary to convert motor to 115 Volt power.
Connect power supply wires to L1 and L2. For 3-phase motors, or if motor does not match these pictures, follow the connection diagram on the motor nameplate.
MOTOR SWITCH SETTINGS
Dual-voltage motors (motors that can operate at either 115 or 230 volts), are set at the factory to 230 volts. Do not change motor voltage setting if line voltage is 230 volts, or if you have a single voltage motor.
NOTICE: Never wire a 115 volt motor to a 230 volt line.
REMOVE MOTOR END COVER
If you have a dual-voltage motor, and will connect it to 115 volts, follow the procedure below.
You will need to remove the motor end cover to change the voltage setting.
Your motor terminal board (located under the motor end cover) should look like one of those below.
PLUG TYPE VOLTAGE SELECTOR
To change to 115 volts:
1. Make sure power is off.
2. Pull the plug straight up.
3. Move and attach the plug at the 115 volt position.
The plug will now cover 2 metal tabs. The arrow on the plug will point to 115V.
4. Attach the power lead wires to the power lead terminals. Make sure the wires are secure.
5. Attach the ground wire to the green ground screw
6. Reinstall the Motor end cover Go to Wiring Connections below.
DIAL TYPE VOLTAGE SELECTOR
To change to 115 volts:
1. Make sure power is off.
2. Turn the dial counter-clockwise until 115 shows in the dial window.
3. Attach the power lead wires to the power lead terminals. Make sure the wires are secure.
4. Attach the ground wire to the green ground screw
5. Reinstall the Motor end cover Go to Wiring Connections below.
Hazardous voltage. Can shock, burn, or cause death. Disconnect power to motor before working on pump or motor. Ground motor before connecting to power supply.
WIRING CONNECTIONS
Ground motor before connecting to electrical power supply. Failure to ground motor can cause severe or fatal electrical shock hazard.
Do not ground to a gas supply line.
To avoid dangerous or fatal electrical shock, turn OFF power to motor before working on electrical connections.
Supply voltage must be within ±10% of nameplate voltage. Incorrect voltage can cause fire or damage motor and voids warranty. If in doubt consult a licensed electrician.
Use wire size specified in Wiring Chart, Page 7. If possible, connect pump to a separate branch circuit with no other appliances on it.
Wire motor according to diagram on motor nameplate. If nameplate diagram differs from diagrams above, follow nameplate diagram.
1. Install, ground, wire and maintain this pump in accordance with electrical code requirements.
Consult your local building inspector for information about codes.
Figure 6: Removing Motor End Cover
Figure 7: Voltage set to 230 volts, Plug Type
Motor End Cover
End Cover Screws
Voltage Change Plug
Ground Screw
Power Lead Terminals
Figure 8: Voltage set to 230 volts, Dial Type
Voltage Change Dial
Ground Screw
Power Lead Terminals
Electrical / Operation 7
2. Provide a correctly fused disconnect switch for protection while work-ing on motor. Consult local or national electrical codes for switch requirements.
3. Disconnect power before servicing motor or pump. If the disconnect switch is out of sight of pump, lock it open and tag it to prevent unex-pected power application.
4. Ground the pump permanently using a wire of the same size as that specified in wiring chart, below. Make ground connection to green grounding terminal under motor canopy marked GRD. or .
5. Connect ground wire to a grounded lead in the service panel or to a metal underground water pipe or well casing at least 10 feet long. Do not connect to plastic pipe or insulated fittings.
6. Protect current carrying and grounding conductors from cuts, grease, heat, oil, and chemicals.
7. Connect current carrying conductors to terminals L1 and L2 under motor canopy. When replacing motor, check wiring diagram on motor nameplate against Figure 6. If the motor wiring diagram does not match either diagram in Figure 6, follow the diagram on the motor.
IMPORTANT: 115/230 Volt single phase models are shipped from factory with motor wired for 230 volts. If power supply is 115 volts, remove motor canopy and reconnect motor as shown in Figure 6. Do not try to run motor as received on 115 volt current.
8. Motor has automatic internal thermal overload protection. If motor has stopped for unknown reasons, thermal overload may restart it unexpect-edly, which could cause injury or property damage. Disconnect power before servicing motor.
9. If this procedure or the wiring diagrams are confusing, consult a licensed electrician.
PRIMING THE PUMP
NOTICE: ‘Priming’ refers to the pump expelling all air in the system and begin-ning to move water from its source out into the system. It does not refer only to pouring water into the pump (although pouring water in is usually the first step).
NOTICE: NEVER run pump dry. Running pump with out water in it will damage seals and can melt impeller and diffuser. To prevent damage, fill pump with water before starting.
1. Remove priming plug (Figure 9).
2. Make sure suction and discharge valves and any hoses on discharge side of pump are open.
Wiring Chart – Recommended Wire and Fuse Sizes
DISTANCE IN FEET(METERS) FROM MOTOR TO SUPPLY
0 - 50 51 - 100 101 - 200 201 - 300 Max. Load Volts/Hz Branch Fuse (0 - 15) (31 - 61) (62 - 91) (92 - 122)
Model HP Amp Phase Rating Amp AWG WIRE SIZE (mm2)
DS3HE-01 1 14.8/7.4 115/230/60/1 20/15 12/14 (3/2) 12/14 (3/2) 8/14 (8.4/2) 6/14 (14/2)
DS3HE3-01 1 3.6/1.8 230/460/60/3 15/15 14/14 (2/2) 14/14 (2/2) 14/14 (2/2) 14/14 (2/2)
DS3HF-01 1-1/2 20/10 115/230/60/1 25/15 10/14 (5.5/2) 10/14 (5.5/2) 8/14 (8.4/2) 6/12 (14/3)
DS3HF3-01 1-1/2 4.7/2.35 230/460/60/3 15/15 14/14 (2/2) 14/14 (2/2) 14/14 (2/2) 14/14 (2/2)
DS3HG-01 2 24/12 115/230/60/1 30/15 12/14 (3/2) 10/14 (5.5/2) 6/14 (14/2) 6/12 (14/3)
DS3HG3-01 2 5.8/2.9 230/460/60/3 15/15 14/14 (2/2) 14/14 (2/2) 14/14 (2/2) 14/14 (2/2)
DS3HHG-01 2-1/2 26/12 115/230/60/1 35/15 12/14 (3/2) 10/14 (5.5/2) 6/14 (14/2) 6/8 (14/8.4)
DS3HHG3-01 2-1/2 6.9/3.45 230/460/60/3 15/15 14/14 (2/2) 14/14 (2/2) 14/14 (2/2) 14/14 (2/2)
Figure 9: Remove Priming Plug and Fill Pump Before Starting
750 0993
Figure 10: Run Ten Minutes or Less
Figure 11: Do Not Run Pump with Discharge Shut-off
6897 0814
6898 0814
20 100
Maintenance 8
3. Fill pump and suction pipe with water.
4. Replace priming plug, using PTFE pipe thread sealant tape on thread;
tighten plug.
NOTICE: If a priming tee and plug have been provided for a long horizontal run, be sure to fill suction pipe through this tee and replace plug. (Don’t forget to PTFE pipe thread sealant tape the plug.)
5. Start pump: water should be produced in 10 minutes or less, the time depending on depth to water (not more than 20’) and length of horizontal run (10’ of horizontal suction pipe = 1’ of vertical lift due to friction losses in the pipe).
If no water is produced within 10 minutes, stop pump, release all pressure, remove priming plug, refill and try again.
Hazardous pressure and risk of ex plo sion and scalding. If pump is run con ti nu ously at no flow (that is, with discharge shut off or without priming), water may boil in pump and piping system. Under steam pressure, pipes may rupture, blow off of fittings or blow out of pump ports and scald anyone near.
To prevent explosion, do the following:
A. Be sure discharge (valve, pistol grip hose nozzle, etc.) is open whenever pump is running.
B. If pump fails to produce water when attempting to prime, release all pressure, drain pump and refill with cold water after every two attempts.
C. When priming, monitor pump and piping tempera ture. If pump or piping begin to feel warm to the touch, shut off pump and allow system to cool off. Release all pressure in system and refill pump and piping with cold water.
Pump and piping need not be disconnected to repair or replace motor or seal (see Figure 13). If motor is replaced, replace the shaft seal (Key No. 5, Page 12). Keep one on hand for future use.
Be sure to prime pump before starting.
NOTICE: Check motor label for lubrication instructions. The mechanical shaft seal in the pump is water lubricated and self-adjusting.
NOTICE: Drain pump when disconnecting from service or when it might freeze.
PUMP DISASSEMBLY
1. Disconnect power to motor.
NOTICE: Mark wires for correct assembly.
2. Remove capscrews holding seal plate to pump body. Motor assembly and seal plate can now be pulled away from pump body (Figure 13).
CARE FULLY remove gasket.
CLEANING/REPLACING IMPELLER
NOTICE: First, follow instructions under “Pump Dis assembly”.
1. Remove screws fastening diffuser to seal plate; re move diffuser (see
Figure 14). Exposed impeller can now be cleaned.
2. If impeller must be replaced, loosen two machine screws and remove motor canopy (see Figure 15).
3. Capacitor voltage may be hazardous. To discharge capacitor, hold insulated handle screwdriver BY THE HANDLE and short capacitor terminals together (see Figure 15). Do not touch metal screwdriver blade or capacitor terminals. If in doubt, consult a qualified electrician.
ON
OFF
1060B 0997Figure 12: Disconnect Power
Figure 13: Slide Motor Back
3028 0997Figure 14: Remove Diffuser
Figure 15: Hold Shaft
739 0993
To avoid electrical shock hazard, use insulated-handle screwdriver to short capacitor terminals as shown.
739 0993
6899 0814
Maintenance 9
4. Unscrew capacitor clamp and remove capacitor. Do not disconnect capacitor wires to motor.
5. Slide 7/16” open end wrench in behind spring loaded switch on motor end of shaft; hold motor shaft with wrench on shaft flats and unscrew impeller screw (if used) by turning clockwise (left hand thread) when looking into eye of impeller.
6. Unscrew impeller while holding shaft by turning counterclockwise while looking into eye of impeller.
7. To reinstall, reverse steps 1 through 6.
8. See directions under “Pump Reassembly,” Page 10.
REMOVING OLD SEAL
1. Follow instructions under “Pump Disassembly”.
2. Follow steps 2 through 5 under “Cleaning/Replacing Impeller”.
3. Remove rotating half of seal by placing two screw drivers under seal ring and carefully prying up (Figure 16).
4. Remove nuts from studs holding seal plate to motor. Carefully slide seal plate off of shaft.
NOTICE: Be sure you do not scratch or mar shaft; if shaft is marred, it must be dressed smooth with fine emery or crocus cloth before installing new seal. DO NOT reduce shaft diameter!
5. Place seal plate half face down on flat surface and tap out stationary half of seal (see Figure 17).
INSTALLING NEW SEAL
1. Clean seal cavity in seal plate.
2. Wet outer edge of Rubber Cup on ceramic seat with liquid soap. Be sparing!
3. Put clean cardboard washer on seal face. With thumb pressure, press ceramic seal half firmly and squarely into seal cavity (See Figure 18).
Polished face of ceramic seat is up. If seal will not seat correctly, remove, placing seal face up on bench. Reclean cavity. Seal should now seat correctly.
4. If seal does not seat correctly after recleaning cavity, place a cardboard washer over polished seal face and carefully press into place using a piece of standard 3/4” pipe as a press.
NOTICE: Be sure you do not scratch seal face.
5. Dispose of cardboard washer and recheck seal face to be sure it is free of dirt, foreign particles, scratches and grease.
6. Inspect shaft to be sure it is free of nicks and scratches.
7. Reassemble pump body half to motor flange. BE SURE it is right side up.
8. Apply liquid soap sparingly (one drop is sufficient) to inside diameter of rotating seal member.
9. Slide rotating seal member (carbon face first) onto shaft until rubber drive ring hits shaft shoulder.
NOTICE: Be sure not to nick or scratch carbon face of seal when passing it over threaded shaft end or shaft shoulder. The carbon surface must remain clean or short seal life will result.
3029 0997Figure 16: Remove Seal plate
3030 0997Figure 17: Tap Out Seal
3031 0997Figure 18: Press in New Seal
1072 0697
Ceramic Face Carbon
Face
Be Careful That Motor Shaft Shoulder...
...Does Not Damage Seal Face
Figure 19: Protect Seal Faces
Maintenance 10
10. Hold motor shaft with 7/16” open end wrench on shaft flats and screw impeller onto shaft. Be sure you do not touch capacitor terminals with body or any metal object. Tightening impeller will automatically locate seal in correct position.
11. Replace impeller screw (if used) by turning counterclockwise (left-hand thread) into end of shaft.
12. Remount diffuser on seal plate with two screws.
13. Follow instructions under “Pump Reassembly”.
PUMP REASSEMBLY
1. Clean gasket surfaces on pump body and seal plate;
install new gasket.
2. Slide motor/seal plate assembly into pump body.
Secure with capscrews.
3. Replace base mounting bolts.
4. Replace motor wiring; close draincock.
5. Prime pump according to instructions. See “Opera tion.”
6. Check for leaks.
Figure 21: Assemble Pump
Figure 20: Hold Shaft 739 0993
To avoid electrical shock hazard, use insulated-handle screwdriver to short capacitor terminals as shown.
6900-6999
Troubleshooting 11
SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION
Motor will not run Disconnect switch is off Be sure switch is on Fuse is blown Replace fuse Starting switch is defective Replace starting switch Wires at motor are loose, Refer to instructions on wiring. Check and tighten all wiring.
disconnected, or wired incorrectly Capacitor voltage may be hazardous. To discharge capacitor, hold insulated handle screwdriver BY THE HANDLE and short capacitor terminals together. Do not touch metal screwdriver blade or capacitor terminals. If in doubt, consult a qualified electrician.
Motor runs hot and Motor is wired incorrectly Refer to instructions on wiring overload kicks off Voltage is too low Check with power company. Install heavier wiring if wire size is too small (See Electrical, Page 6)
Motor runs but no *Pump in new installation did In new installation:
water is delivered not pick up prime through:
1. Improper priming 1. Re-prime according to instructions
2. Air leaks 2. Check all connections on suction line
3. Leaking foot valve 3. Replace foot valve *Pump has lost prime through: In installation already in use:
1. Air leaks 1. Check all connections on suction line and shaft seal
2. Water level below suction of pump 2. Lower suction line into water and re-prime. If receding water level in well exceeds suction lift, a deep well pump is needed Impeller is plugged Clean impeller; see Maintenance Check valve or foot valve is stuck Replace check valve or foot valve in closed position Pipes are frozen Thaw pipes. Bury pipes below frost line. Heat pit or pump house.
Foot valve and/or strainer are Raise foot valve and/or strainer above well bottom buried in sand or mud
Pump does not Water level in well is lower than A deep well jet pump may be needed (over 20 ft. to water) deliver water to full estimated capacity (Also Steel piping (if used) is corroded or Replace with plastic pipe where possible, otherwise with new steel pipe check point 3 limed, causing excess friction immediately above) Offset piping is too small in size Use larger offset piping
*(Notice: Check prime before looking for other causes. Unscrew priming plug and see if there is water in priming hole.)
Repair Parts 12
• Not illustrated.
* Model DS3HHG3-01 uses Base C4-82.
3621 1199SPC
7A11
�A
1�
�1
1�
MODEL NUMBER
DS3HE-01 DS3HF-01 DS3HG-01 DS3HHG-01
Key Part DS3HE3-01 DS3HF3-01 DS3HG3-01 DS3HHG3-01 No. Description Qty. 1 HP 1-1/2 HP 2 HP 2-1/2 HP
1 Motor, 115/230V, 1 Phase 1 J218-596PKG J218-601PKG J218-883APKG J218-628A 1 Motor, 230/460V, 3 Phase 1 AP100EL AP100FL AP100GL AP100G5L 2 Water Slinger 1 17351-0009 17351-0009 17351-0009 17351-0009 3 Seal Plate 1 C3-155 C3-155 C3-117 C3-117 4 Gasket - Seal Plate 1 C20-86 C20-86 C20-87 C20-87 5 Shaft Seal 1 U109-6A U109-6A U109-6A U109-6A 6 Impeller (1 Phase) 1 C105-92PKB C105-92PC C105-214PDA C105-214PA 6 Impeller (3 Phase) 1 C105-92PKBA C105-92PCA C105-214PDA C105-214PA 6A Impeller Screw (1 Phase) 1 — — C30-14SS C30-14SS 6A Impeller Screw (3 Phase) 1 C30-14SS C30-14SS C30-14SS C30-14SS 7 Diffuser 1 C101-276P C101-276P C101-182 C101-182 7A Screw 10-24 x1” Lg Hex Head 2 U30-696SS U30-696SS — — 7A Machine screw 8-32x7/8” Lg. 2 — — U30-53SS U30-53SS 8 Diffuser Ring 1 C21-10 C21-10 C21-2 C21-2 9 Pump Body Assembly 1 C76-67E C76-67E C76-68E C76-68E 10 Plug 1/4” NPT Hex Head 2 U78-941ZPV U78-941ZPV U78-941ZPV U78-941ZPV 11 Base 1 C4-82 C4-82 C4-82 C4-82A* 12 3/8-16x1-1/4” Lower Capscrew 2 U30-75ZP U30-75ZP U30-75ZP U30-75ZP 13 3/8-16x1” Upper Capscrew 2 U30-74ZP U30-74ZP U30-74ZP U30-99SS 14 Motor Pad 1 C35-5 C35-5 C35-5 C35-5 15 Capscrew 3/8-16x3/4” Lg 6 U30-72ZP U30-72ZP — — 15 Capscrew 5/16-18x3/4” Lg. 8 — — U30-60ZP U30-60ZP 16 Pipe Plug 3/4” NPT - Sq. Hd. 1 U78-60ZPS U78-60ZPS U78-60ZPS U78-60ZPS
| • | Lockwasher | 3/8” | 2 | U43-12ZP | U43-12ZP | U43-12ZP | U43-12ZP | |||
| • | Nut, | 3/16”-18 | Hex | Head | 2 | U36-37ZP | U36-37ZP | U36-37ZP | U36-37ZP |
K-Rain Manufacturing Corp.
1640 Australian Avenue Riviera Beach, FL 33404 USA 561.844.1002
FAX: 561.842.9493
1.800.735.7246 | www.krain.com
PUMP START RELAY
1500 SERIES
n Standard, rain, tight, secure, rustproof and flame retardant enclosure – provides a safe and secure connection in an enclosure that will last a lifetime.
n U.L. rated relay – ensures that the relays are approved for its intended use.
n Large easy access enclosure – provides easy accessibility during wiring.
n Enclosure has versatility installation – provides for easy connections.
n 110 VAC or 24 VAC coils available – provides for a variety of applications up to 7.5 HP.
n 2 year warranty – factory support up to two years after purchase.
The Pump Start Relay enclosure is constructed with a Corrosion, UV and flame retardant resistant shockproof material.
© K-Rain Manufacturing Corporation
AN ISO 9001 CERTIFIED COMPANY
Models 1510 Coil Specifications Double Pole, Single Throw 120V AC, 60 Hz Inductive: 20 AMP Inrush: 35 VA Resistive: 30 AMP Sealed: 7.0 VA Input: 120V AC - up to 2 H.P.
Resistance (±10%): UL Rated
250 OHMS
Mini Coil 24V AC, 50/60 Hz Sealed: 1.2 VA Inrush: 52 mA Resistance (±10%): 155 OHMS
1520 Coil Specifications Double Pole, Single Throw 240V AC, 60 Hz Inductive: 20 AMP Inrush: 35 VA Resistive: 30 AMP Sealed: 7.0 VA Input: 240V AC - up to 3 H.P.
Resistance (±10%): UL Rated
1000 OHMS
Mini Coil 24V AC, 50/60 Hz Sealed: 1.2 VA Inrush: 52 mA Resistance (±10%): 155 OHMS
1521 Coil Specifications Double Pole, Single Throw 120V AC, 60 Hz Inductive: 20 AMP Inrush: 42 VA Resistive: 30 AMP Sealed: 8.5 VA, 3.6 Watts Input: 120V AC - up to 3 H.P.
Resistance (±10%): 240V AC - up to 3 H.P.
210 OHMS
1522 Coil Specifications Double Pole, Single Throw 24V AC, 60 Hz Inductive: 20 AMP Inrush: 35 VA Resistive: 30 AMP Sealed: 7 VA, 3 Watts Input: 120V AC - up to 3 H.P.
Resistance (±10%): 240V AC - up to 3 H.P.
11 OHMS
1551 Coil Specifications Double Pole, Single Throw 120V AC, 60 Hz Inductive: 40 AMP Inrush: 77 VA Resistive: 50 AMP Sealed: 10 VA, 4 Watts Input: 120V AC - up to 3 H.P.
Resistance (±10%): 240V AC - up to 5 H.P.
89.5 OHMS
1552 Coil Specifications Double Pole, Single Throw 24V AC, 60 Hz Inductive: 40 AMP Inrush: 60 VA Resistive: 50 AMP Sealed: 7 VA, 2.3 Watts Input: 120V AC - up to 3 H.P.
Resistance (±10%): 240V AC - up to 5 H.P.
5.61 OHMS
1553 Coil Specifications THREE PHASE OPERATION 24V AC, 60 Hz Triple Pole, Single Throw Inrush: 60 VA Inductive: 40 AMP Sealed: 7 VA, 2.7 Watts Resistive: 50 AMP Resistance (±10%): Input: 120V AC - up to 3 H.P.
5.61 OHMS 240V AC - up to 10 H.P.
Dimensions n Height: 7.25"/14.5 cm n Width: 6.25"/11.4 cm n Depth: 3.875"/6.1 cm
MConneen Rectangle
1500 SERIES
PUMP START RELAYS
The Pump Start Relay enclosure is constructed with a corrosion resistant and shockproof material. The rain-tight, secure, rustproof enclosure provides a safe and secure connection in a housing built to last.
TWO YEAR LIMITED WARRANTY
K-Rain products carry a “Limited Warranty.” For two years from the date of purchase, K-Rain will repair or replace (at K-Rain’s option) the product or any part if the product is found to be defective as to workmanship or material.
This warranty does not extend to damage to a K-Rain product resulting from misuse, neglect or abuse, normal wear and tear, or accident, to exterior appearance or color or due to improper installation. This warranty extends only to an original user of a K-Rain product.
In no event shall K-Rain be liable for incidental or consequential damages. All implied warranties are limited in duration to two years following date of purchase. Some states do not permit the exclusion or limitation of incidental or consequential damages or of implied warranties. Therefore, the above exclusions or limitations may not apply to you.
If a defect arises in a K-Rain product within the 2-year warranty period, you should promptly contact your K-Rain installer, distributor, or K-RAIN MANUFACTURING CORP. at the address below.
Please allow up to 4 weeks for completion of repairs or replacement and return of the product. If a product is replaced, the replacement product is covered only for the remainder of the original warranty period dating from the purchase of the original product.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
If you have any questions concerning the warranty or its application, please write to: K-Rain Manufacturing Corporation, Attn: Product Manager, at the address below.
K-RAIN MANUFACTURING CORP.
1640 Australian Avenue Riviera Beach, FL 33404 USA
PH: 1-561-844-1002 / 1-800-735-7246
FAX: 1-561-842-9493
WEB: http://www.krain.com
L-9025001 (03/08)
© K-RAIN Manufacturing Corp.
WIRING DIAGRAM
Copper wire only, sized per 75 degrees C tables in accordance with NEC. Tightening torque of 22 lb-in for relay terminals.
Hub should be connected to conduit before the hub is connected to the enclosure. This enclosure must be installed so the orientation of the drain hole in the back cover is at the bottom of the enclosure. Metal conduit entering and exiting the enclosure must be secured to the enclosure using threaded grounding bushings, which are then connected to each other using a ground wire of sufficient size.
TECHNICAL SPECIFICATIONS
Suitable for use on a circuit capable of delivering not more than 5000 RMS symmetrical amperes, 240 Volts maximum, when protected by fuses or beakers rated maximum 100 Amps.
TYPE 3R
RAINPROOF
IND. CONT. EQ.
22LB
MODEL COIL SPECIFICATIONS CONTACT RATING
1522 24 Vac, 60 Hz; Inrush: 35 VA Double Pole, Single Throw; Inductive: 20 AMP;
24 VAC coil Sealed: 7 VA, 3 watts Resistive: 30 AMP; Input: 120 VAC - up to 3 HP;
Resistance: (±10%): 11 ohms 240 VAC - up to 3 HP
1521 120 Vac, 60 Hz; Inrush: 35 VA Double Pole, Single Throw; Inductive: 20 AMP;
120 VAC coil Sealed: 7 VA, 3.6 watts Resistive: 30 AMP; Input: 120 VAC - up to 3 HP;
Resistance: (±10%): 250 ohms 240 VAC - up to 3 HP
1552 24 Vac, 60 Hz; Inrush: 35 VA Double Pole, Single Throw; Inductive: 40 AMP;
24 VAC coil Sealed: 7 VA, 2.3 watts Resistive: 50 AMP; Input: 120 VAC - up to 3 HP;
Resistance: (±10%): 11 ohms 240 VAC - up to 5 HP
1551 120 Vac, 60 Hz; Inrush: 53 VA Double Pole, Single Throw; Inductive: 30 AMP;
120 VAC coil Sealed: 5 VA, 5 watts Resistive: 40 AMP; Input: 120 VAC - up to 3 HP;
Resistance: (±10%): 180 ohms 240 VAC - up to 5 HP
1553 24 Vac, 60 Hz; Inrush: 53 VA Triple Pole, Single Throw; Inductive: 40 AMP;
24 VAC coil Sealed: 5 VA Resistive: 50 AMP; Input: 120 VAC - up to 3 HP;
Resistance: (±10%): 7 ohms 240 VAC - up to 10 HP
1559 240 Vac, 60 Hz; Inrush: 53 VA Triple Pole, Single Throw; Inductive: 40 AMP;
240 VAC coil Sealed: 5 VA Resistive: 50 AMP; Input: 120 VAC - up to 5 HP;
Resistance: (±10%): 720 ohms 240 VAC - up to 10 HP
1510* 24 Vac, 60 Hz; Inrush: 52 mA Double Pole, Single Throw; Inductive: 20 AMP;
24 VAC mini coil Sealed: 1.2 VA; Resistance: (±10%): 155 ohms Resistive: 30 AMP; Input: 120 VAC - up to 3 HP
120 VAC coil 120 Vac, 60 Hz; Inrush: 35 VA Sealed: 7 VA; Resistance: (±10%): 250 ohms
1520* 24 Vac, 60 Hz; Inrush: 52 mA Double Pole, Single Throw; Inductive: 20 AMP;
24 VAC mini coil Sealed: 1.2 VA; Resistance: (±10%): 155 ohms Resistive: 30 AMP; Input: 240 VAC - up to 3 HP
240 VAC coil 240 Vac, 60 Hz; Inrush: 35 VA Sealed: 7 VA; Resistance: (±10%): 1000 ohms
*Includes a UL Rated Relay.
MConneen Rectangle
Tech Spec
ESP-ME3 Modular Controller ESP-ME3 Series Controllers America’s favorite modular controller, the ESP-Modular is now WiFi and fl ow sensor compatible with new design and an enhanced feature set to provide contractors with the industry’s most fl exible irrigation controller solution. The ESP-ME3 Controller supports up to 22 stations, 4 programs and 6 start times.
Applications The ESP-ME3 WiFi Compatible Controller provides fl exible scheduling features that make the controller ideal for all your irrigation controller needs.
Easy to Use The ESP-ME3 WiFi Compatible Controller was designed with ease of use in mind.
The controller boasts the industry’s largest back-lit LCD screen for its class and also incorporates universal icons on both the controller overlay and the LCD.
Easy to Install The ESP-ME3 WiFi Compatible Controller mounts with as few as two mounting screws. A guide for ½“or ¾” conduit fi ttings allows for professional installation of fi eld wires into the cabinet. For larger fi eld wire needs, remove the knockout for a 1” diameter opening.
Controller Hardware
• Plastic wall-mount case with door
• 4 station base module
• Mounting Screws
• Wire nuts for outdoor models
Controller Features
• Large LCD display with easy to navigate user interface
• Rain Sensor input with override capability
• Master valve/pump start circuit
• Non-Volatile (100 year) storage memory
• Remotely Programmable under 9V battery power (not included)
Scheduling Features
• Program based scheduling allows 4 individual programs with 6 independent start times per program for 24 total start times
• Watering schedule options: By days of week, ODD calendar days, EVEN calendar days, or Cyclic (every 1 – 30 days)
Advanced Features
• Advanced diagnostics and short detection with LED alert
• Contractor Default™ Program Save/ Restore saved program(s)
• Rain Sensor bypass by Station
• One Touch manual watering
• Delay Watering up to 14 days (applies only to stations not set to ignore Rain Sensor)
• Manual Watering option by program or station
• Seasonal Adjust applied to all programs or individual program
• Adjustable delay between valves (default set to 0)
• Master Valve on/off by station
Operating Specifi cations
• Station timing: 1 minute to 6 hours
• Seasonal Adjust: 5% to 200%
• Max operating temperature: 149°F (65°C)
Electrical Specifi cations
• Input required: 120VAC ± 10%, 60Hz
(International models:
230VAC ± 10%, 50/60Hz)
• Output: 25.5VAC 1A
• Master Valve/Pump Start Relay Operating Voltage: 24VAC 50/60Hz Max Coil Inrush: 11VA Max Coil Holding: 5VA
• Idle/Off power draw 0.06 amps at
120VAC
• Power back-up not required. Nonvolatile memory permanently saves the current programming and a 10 year life lithium battery maintains the controllers time and date during power outages.
How to specify your model:
ESP-ME3 WiFi Compatible Controller 120V 4 station base controller
Indoor/Outdoor ESP4ME3
230V (available in outdoor models only)
ESP4ME3EUR 230V markets except Australia
ESP4ME3AUS 230V Australia
Expansion Modules for all models
ESPSM3 3 station expansion module
ESPSM6 6 station expansion module
Certifi cations
• cULus [US and Canada], FCC Part 15b
[US], CAN ICES-3(B)/NMB-3(B) [Canada], NOM [Mexico], CE [European Union], IRAM [Argentina], INMETRO [Brazil], IPX4, RCM [Australia and New Zealand], IP24.
• WaterSense© certifi ed with up to 30% water savings when installed with Rain Bird LNKTM
WiFi Module and WR2 Rain Sensor. Meets EPA criteria for high-performing, water-effi cient products.
Dimensions
• Width: 10.7 in. (27,2 cm)
• Height: 7.7 in. (19,5 cm)
• Depth: 4.4 in. (11,2 cm)
Rain+Birdt tRegistered trademark of Rain Bird Corporation 2019 Rain Bird Corporation
Rain Bird Corporation 6991 East Southpoint Road Tucson, AZ 85756 Phone: (520) 741-6100 Fax: (520) 741-6522
Rain Bird Technical Services
(800) RAINBIRD (1-800-724-6247)
(U.S. and Canada)
Rain Bird Corporation 970 West Sierra Madre Ave.
Azusa, CA 91702 Phone: (626) 812-3400 Fax: (626) 812-3411
Specification Hotline 1-800-458-3005 (U.S. and Canada)
Rain Bird International, Inc.
1000 West Sierra Madre Ave.
Azusa, CA 91702 Phone: (626) 963-9311 Fax: (626) 852-7343
The Intelligent Use of Water TM www.rainbird.com
Specifications The ESP-ME3 Controller shall be capable of fully automatic or manual operation. The controller shall be housed in a wall-mountable, weather resistant plastic cabinet with a key-locking cabinet door suitable for either outdoor or indoor installation.
The controller shall include a base unit module with 4 stations as well as three expansion slots capable of receiving expansion station modules of either three or six stations to achieve total station capacity of up to 22 stations.
The controller shall accept the modules in any configuration and shall not require the installation of a three station module in order to install a 6 station module.
Station run times shall range from 1 minute to 6 hours. The controller shall be set with a factory default start time of 8 AM and default run time of 10 minutes for the first 4 stations for Program A only.
The controller shall have a Seasonal Adjust feature to adjust the run time for all stations from 5% to +200% in 5% increments. Seasonal Adjust can be applied to all programs simultaneously or individually.
The controller shall have 4 independent programs that can have 6 different start times.
The controller shall stack multiple start times in sequence to prevent hydraulic overload. All programs run consecutively.
The controller shall be capable of operating two 24VAC solenoid valves per station plus a master valve or remote pump start relay. The controller shall operate on 120VAC± 10% at 60Hz (230VAC ± 10% at 50Hz for international models). A master valve or pump start relay shall operate on 24VAC at 50/60Hz, Max Coil Inrush of 11VA and Max Coil Holding of 5VA.
Watering day cycles shall be: By Day of the week, Odd, Even and Cyclic (Every # day). Odd, Even, and Cyclic shall support permanent days off. A day set to “Permanent Off” shall override the normal repeating schedule.
The controller shall have an electronic diagnostic circuit breaker that shall sense a station with an electrical overload or short circuit and shall bypass that station and continue to operate all other stations. When an electrical condition exists that is preventing normal operation the red LED shall illuminate continuously and scroll a message across the LCD as to what the problem
is. When an alert condition is…