Attach 4 OM Manuals- Softball Field.pdf
PDF 13 MB Posted
- Attached to
- Patrick SFB Athletic Field
- Solicitation number
- FA252124QA006
About this file
This document appears to be an attachment of OM (Operations and Maintenance) Manuals for a Softball Field as part of a federal contract opportunity.
The related federal contract opportunity is for Athletic Fields Maintenance Services at Patrick Space Force Base. The solicitation number is FA252124QA006, and the contracting agency is the Department of the Air Force Space Command. The purpose is to obtain personnel, supervision, labor, tools, transportation, materials, and equipment necessary to perform the required maintenance services on the athletic fields. No additional details on specific products, services, response dates, award dates, pricing terms, set asides, or incumbents are provided in this document. This appears to be just a document attachment and not the full solicitation or contract.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Frazier Engineering, Inc. • 6767 North Wickham Road, Suite 304, Melbourne, FL 32940 • 321-253-8131
Construction & Engineering Woman-Owned, MBE www.fraziereng.com
Operation and Maintenance Manuals for
Contract FA2521-23-C-0020 [SXHT 23-1019] 45 Contracting Squadron PSFB
Repairs Softball Field, Patrick Space Force Base [Schobel Softball Field) 82 S Poinciana Dr, Satellite Beach, FL 32937 [4105 S. Poinciana Dr.]
Table of Content
- Division 2: Sod – Grow In Program 2
- Division 2: Irrigation – Timer, Pump, Heads, and Valves 4
- Division 10: Scoreboard 34 http://www.fraziereng.com/
Frazier Engineering, Inc. • 6767 North Wickham Road, Suite 304, Melbourne, FL 32940 • 321-253-8131
- Division 2: Sod – Grow In Program
GROW IN PROGRAM FOR BERMUDEAGRASS ATHLETIC FIELDS
WATERING
Planted areas should be watered immediately following installation and kept continuously moist for a period of two weeks. This means frequent, light watering (4-6 times per day) rather than soaking the soil when it becomes dry. Do not allow the water to puddle or run off the surfaces. After three weeks, irrigate each area at least once per day until the grass is completely rooted down.
FERTILIZING
Weeks After Planting Material Rate/Acre (Ibs.)
2 Ammonium Sulfate 200 4 12-4-8, or similar analysis 400
Repeat the above cycle until the surfaces are covered.
Note: Be sure the grass is dry when fertilizer is applied and irrigate immediately following the application.
PEST CONTROL
Follow direction and precautions on the pesticide container label. Be sure the pesticide is labeled for use on the bermudagrass, and the pest is listed on the label. For effective control of pests without damage to the turf, the sprayer must ne calibrated and operating properly.
INSECT CONTROL
Inspect the planting daily for the presence of mole crickets and/or worms. Treat as needed, carefully following label rates and precautions. Use Bifenithrin or Acephate for control of either pest. Other than allowing the soil to dry out, worm infestation is the biggest contributor to loss of newly installed turfgrass.
WEED CONTROL
Broadleaf Weeds – Most can be controlled using one ot a combination of the following: 2, 4-D. Trimec, Manor, Banvel, Dismiss or Celsius 68WDG.
Grass-Type Weeds – Most can be controlled using one or a combination of the following: Sencor, Dismiss, Revolver, or Drive.
Sedge-Type Weeds – For best control use Sedgehammer, Dismiss South, Certainty, or Monument.
Caterpillars – Can be controlled by using one of the following: Orthene, Sevin, Talstar, Dursban, and Acelypryn.
Mole Crickets – Insecticides for control include Acephate, Bifenthrin, Sevin bait, Chipco TopChoice.
ROLLING
To provide a smooth, firm surface for future play and operation of mowing equipment, all areas will need to be rolled a few times
Frazier Engineering, Inc. • 6767 North Wickham Road, Suite 304, Melbourne, FL 32940 • 321-253-8131
- Division 2: Irrigation – Timer, Pump, Heads, and Valves
LNKTM Ready
ESP-ME3 Controller Advanced User Manual
ESP-ME3 Controller2
EN ESP-ME3 Controller · Advanced User Manual
Technical Support Questions?
Call Rain Bird toll free Technical Support at 1-800-724-6247 (USA and Canada only)
Hazardous Warnings
CWARNING
Indicates a hazardous situation that, if not avoided, could result in death or serious injury.
CCAUTION
Indicates a hazardous situation that, if not avoided, could result in minor or moderate injury.
NOTICE
Indicates information considered important, but not hazard-related (e.g., messages relating to property damage).
SAFETY INSTRUCTIONS
Specific safety-related instructions or procedures are described.
Symbols & User Operation a NUMBERS define a series of steps for the user to follow in order to operate the controller.
B NOTE: Notifies the user of important operating instructions related to controller functionality, installation or maintenance.
H REPEAT: Indicates that a repetition of previous steps or actions may be required for further oper-ation, or to complete a process.
Contents Technical Support
Introduction Welcome to Rain Bird®
The Intelligent Use of Water®
ESP-ME3 Controller Features WiFi Enabled
Installation Mount Controller
Connect Valves Connect Master Valve (optional) Connect Pump Start Relay (optional) Connect Flow Sensor (optional) Connect Weather Sensor (optional) Connect Power
Station Expansion Modules Install Modules Station Numbering
Complete Controller Installation
Normal Operation Controls and Features
AUTO
OFF
Display Indicators
Basic Programming
1. Set Date and Time
2. Set Watering Start Times
3. Set Station Run Times
4. Set Water Days Custom Days of the Week
Program-Based Scheduling Common Programming Error
Manual Watering Options Test All Stations
Run a Single Station
Run a Single Program
Advanced Programming Odd or Even Calendar Days
Cyclic Days
Seasonal Adjust
Delay Watering
Permanent Days Off
Special Features Options
Reset Button
Remote Accessories
Detached Programming
Battery Life
Appendix Troubleshooting
Error Detection Programming Errors (blinking LED) Electrical Errors (non-blinking LED) Flow Alarms Watering Issues Electrical Issues (solid LED illuminated)
Certifications
Safety Information
ESP-ME3 Controller3
EN Introduction Welcome to Rain Bird®
Thank you for choosing Rain Bird’s ESP-ME3 controller.
In this manual are step by step instructions for how to install and operate the ESP-ME3.
The Intelligent Use of Water® We believe it is our responsibility at Rain Bird to develop products that use water efficiently.
ESP-ME3 Controller Features
Feature Description Maximum Stations 22 (with optional Station
Modules) Master Valve or Pump Start Relay
Supported
Start Times 6 Programs 4 Program Cycles Custom Days, Odd, Even and
Cyclic Permanent Days Off By program Master Valve Control On/Off per station Rain Delay Supported Rain/Freeze Sensor Supported Rain Sensor Control Global or by station Seasonal Adjust Global or by program Manual Watering Run Yes Manual Program Run Yes Manual Test All Stations Yes Short Detect Yes Delay Between Stations Set by program Accessory Port Yes (5 pin) Save & Restore Program-ming
Yes
Station Advance Yes LNKTM WiFi Module Supported Flow Sensor Supported Cycle+SoakTM Supported in Rain Bird App via LNKTM WiFi Module
WiFi Enabled The LNKTM WiFi Module allows remote connection to a Rain Bird ESP-ME3 Controller using an Apple® iOS® or AndroidTM compatible smart device. The mobile appli-cation allows remote access and configuration of one or more irrigation controllers.
* Apple is a trademark of Apple Inc, IOS is a trademark of Cisco Systems Inc, and Android is a trademark of Google LLC.
For more information on the LNKTM WiFi Module and the value this product can provide for your ESP-ME3 controller, please visit: http://wifi-pro.rainbird.com
LNKTM WiFi Module (sold separately)
Manage Sites Remotely
ESP-ME3 Controller4
EN Installation Mount Controller
B NOTE: Choose a suitable mounting location close to a 120VAC wall outlet.
a Drive a mounting screw into the wall, leaving an 1/8 inch gap between the screw head and the wall surface (use the supplied wall anchors if necessary), as shown.
b Locate the keyhole slot on back of the controller unit and hang it securely on the mounting screw.
1/8 IN.
a b c Open the front panel, and drive three additional screws through the open holes inside the controller and into the wall, as shown.
c a b
MASTER
VALVE
COMCOM
MVMV
SENSSENS
e c
Connect Valves a Route all field wires through the opening at the bottom or back of the unit. Attach conduit if desired, as shown.
CWARNING
Do not route valve wires through the same opening as power wires.
b Connect one wire from each valve to the terminal on the Base Module or Station Module that corresponds to the desired station number (1-22).
c Connect a field common wire to the COM (common)terminal on the Base Module. Then connect the remaining wire from each valve to the field common wire, as shown.
d To perform a Valve Test, connect the common wire to the COM terminal and the power wire to the VT terminal. This will immediately turn the valve ON.
Connect Master Valve (optional) e Connect a wire from the master valve to the MV (master valve) terminal on the Base Module.
Then connect the remaining wire from the master valve to the field common wire, as shown.
ESP-ME3 Controller5
EN Connect Pump Start Relay (optional) a Connect a wire from the PSR (pump start relay) to the MV (master valve) terminal on the Base Module. Then connect another wire from the pump start relay to the field common wire, as shown.
b To avoid the possibility of damage to the pump, connect a short jumper wire from any unused terminal(s) to the nearest terminal in use, as shown.
NOTICE
The ESP-ME3 controller DOES NOT provide power for a pump. The relay must be wired according to manu-facturer instructions.
Only the following Rain Bird pump start relay models are compatible with the ESP-ME3:
Description Note Model No.
Universal Pump Relay 110 volt only
PSR110IC
Universal Pump Relay 220 volt only
PSR220IC
Connect Flow Sensor (optional)
B NOTE: Install the flow sensor in the field accord-ing to the manufacturer’s instructions.
a Run the flow sensor wires to the controller.
CWARNING
Do not route valve wires through the same open-ing as power wires.
b Connect both flow sensor wires to the Flow terminals, as shown. Be sure to connect the positive (sometimes red) sensor wire to the red (+) terminal and the negative (sometimes black) sensor wire to the grey (-) terminal.
b
Flow Sensor Settings
Set the controller to obey or ignore a flow sensor.
When set to Sensor ON, automatic irrigation will be suspended per station if detected flow exceeds learned flow by more than 30%. When set to Sensor OFF, all stations will ignore the flow sensor.
Turn the dial to Flow Sensor.
• Press or to select SENS ON (sensor on) or SENS OFF (sensor off).
Sensor ON Sensor OFF Flow detected (flashing)
B NOTE: When switching from Sensor OFF to Sen-sor ON, the controller will begin to LEARN FLOW.
It will run each station for short period to set the expected station flow.
B NOTE: See Troubleshooting section of the Appen-dix for Flow Alarms information.
a B NOTE: Connection to pump and external power not shown.
Refer to pump instal-lation instructions.
PUMP START
RELAY
b
COMCOM
PSRPSR
ESP-ME3 Controller6
EN Connect Weather Sensor (optional) a Remove the yellow jumper wire from the SENSOR terminals on the controller.
NOTICE
Do not remove the yellow jumper wire unless con-necting a rain sensor.
b Connect both rain sensor wires to the SENSOR terminals as shown.
CWARNING
Do not route the rain sensor wires through the same opening as the power wiring
B NOTE: Rain Bird ESP-ME3 controllers are only compatible with normally closed rain sensors.
B NOTE: For wireless rain/freeze sensors, refer to the sensor installation instructions.
b
Connect Power
CWARNING
DO NOT plug in the transformer or connect external power until you have completed and checked all wiring connections.
Installation with Pre-attached Cord
• Plug the attached power cord into a nearby 120VAC electrical outlet.
Weather Sensor Settings
Set the controller to obey or ignore a weather sensor.
When set to Sensor ON, automatic irrigation will be suspended if rainfall is detected. When set to Sensor OFF all stations will ignore the rain sensor.
Turn the dial to Weather Sensors.
• Press or to select SENS ON (sensor on) or SENS OFF (sensor off).
Sensor ON Sensor OFF Rain detected (flashing)
ESP-ME3 Controller7
EN Outdoor Installation with Direct Wiring
CWARNING
Electric shock can cause severe injury or death. Make sure power supply is turned OFF before connecting power wires.
POWER WIRING CONNECTIONS 120VAC
Black supply wire (hot) to the black transformer wire
White supply wire (neutral) to the white transformer wire
Green supply wire (ground) to the green transformer wire a Locate the transformer wiring compartment in the lower left corner of the controller unit. Use a screwdriver to remove the cover and expose the transformer connection wires.
b Route the three external power source wires through the conduit opening at the bottom of the unit and into the wiring compartment.
c Using the provided wire nuts, connect the external power source wires (two power and one ground) to the transformer connection wires inside the wiring compartment.
CWARNING
Ground wire must be connected to provide electrical surge protection. Permanently mounted conduit shall be used for connecting main voltage to the controller d Verify that all wiring connections are secure, then replace the wiring compartment cover and secure it with the screw.
a c b
Station Expansion Modules Optional Station Modules can be installed in the empty slots to the right of the Base Module to increase the station capacity up to 22 stations.
B NOTE: 6-Station Modules are compatible with ESP-ME3 and ESP-Me. They are not backwards compatible with the ESP-M vintage controller.
B NOTE: For ideal station sequencing, insert 3-Sta-tion module after inserting all 6-station modules.
For more details see the Station Numbering sec-tion.
3-STATION
(ESPSM3) 6-STATION
(ESPSM6)
Expansion Modules (sold separately)
Base Module (included)
Install Modules a Verify the securing lever on the module is in the unlocked position (slide to the left).
b Place the module under the desired slot between the plastic rails.
c Push the module up into the slot until secure.
d Slide the securing lever to the locked position (slide to the right).
bcd a
H REPEAT for additional modules.
B NOTE: Modules can be installed or removed with OR without AC power connected. They are con-sidered “hot-swappable”.
B NOTE: It take about 30 seconds for stations to become available for configuration after install-ing a new module.
ESP-ME3 Controller8
EN Station Numbering The controller is configured with “fixed station num-bering”, meaning that Bays Two, Three and Four can accept either a 3 or a 6-Station Module. If a 6-Station Module is NOT installed then the unused stations are reserved for future use.
Example of Station Numbering when using two 3-Station Modules. A total of 10 stations are installed.
Bay One Bay Two Bay Three Bay Four
• The Base Module is installed in Bay One and uses Stations 1 through 4.
• A 3-Station Module is installed in Bay Two and uses stations 5 through 7. Stations 8 through 10 are skipped and will be unavailable.
• A 3-Station Module is installed in Bay Three and uses stations 11 through 13.
During programming, the controller will skip any unused stations, creating a gap in station numbering.
The unused stations will show on the display as 8SKIP, 9SKIP, etc.
If the screen displays 20NOMOD where the 20 is flash-ing, then there is no module installed for that station number.
Complete Controller Installation a Reinstall and reconnect the front panel.
b Apply power to the controller and test the system.
B NOTE: The electrical connections can be checked even if water is not available. If water is available and you would like to test some or all of your stations, use the Test All Stations feature of the controller.
Normal Operation Controls and Features Program
Select Button Select Program
A, B, C or D
Start Times Up to 6 Start
Times per program
Run Times Set station Run Times
Manual Watering Start watering for one or all stations
Weather Sensors Set controller to obey or ignore a weather sensor
Seasonal Adjust Adjust Run Times from 5% up to 200% Back/Next Buttons
Select programming options
– / + Buttons Adjust feature settings
OFF
Disables automatic irrigation
AUTO
Watering occurs automatically
Date/Time Set the current Date and Time
ALARM
Indicator
Hold to Start Manual irrigation
Water Days Select days to allow watering
Flow Sensor Set the controller to obey or ignore a flow sensor
ESP-ME3 Controller9
EN
AUTO
AUTO is the normal operating mode. Return the dial to AUTO when programming is complete.
During Watering:
The display shows a blinking sprinkler symbol, the active Station Number or Program, and the Remaining Run Time.
• To cancel watering, turn the dial to OFF for three seconds until the screen shows OFF.
To Manually Start a Program:
a Press the Program Select button to select a program.
b Press and hold the Hold to Start button to immediately start manual watering for the selected program.
OFF
Turn the dial to OFF to stop automatic irrigation or to cancel all active watering immediately.
NOTICE
Watering will NOT occur if the controller remains in the OFF position.
B NOTE: Manual watering can be started using mobile apps or LIMR when dial is in OFF position.
Display Indicators
Display Func-tion
Description
ALL ALL All stations
CLEARED CLEARED
Programming was cleared
CYCLIC CYCLIC
Watering occurs at specific intervals, such as every 2 days
DELAY DELAY Delay Watering Active
EVEN EVEN Even days watering
FLOW FLOW Flow Sensor
MV ON MV ON
Master or Pump-start relay is active
NOMOD NOMOD
No station modules installed for that station
ODD ODD Odd days watering
OFF OFF
Controller will not water
PERMOFF PERMOFF
Permanent days off for Odd, Even, Cyclic watering
RAIN RAIN Rain Sensor
RESTORD RESTORD Programming restored
SAVED SAVED Save programming
SENS ON SENS ON
Sensor will function if wired
SEN OFF SEN OFF
Sensor is ignored even if wired
SKIP SKIP
Station not used due to station module config-uration
SOAK SOAK
Soak time between wa-tering times - support-ed through the Rain Bird app.
ESP-ME3 Controller10
EN Basic Programming
1. Set Date and Time
Turn the dial to Date / Time a Press or to select the setting to change.
b Press or to change the setting value.
c Press and hold or to accelerate adjustments.
To change the time format (12 hour or 24 hour):
d With Day of Month blinking, press .
e Press or to select the desired time format, then press to return to the time setting.
2. Set Watering Start Times Up to six Start Times are available for each program.
Turn the dial to Start Times a Press Program Select to choose the desired Program (if necessary).
b Press or to select an available Start Time.
c Press or to set the selected Start Time (ensure the AM/PM setting is correct).
d Press to set additional Start Times.
e To turn off a start time press until 12:00 AM (00:00 in 24 HR), then press one more time for
OFF.
B NOTE: The OFF Position for any start time is between 11:45 PM and 12:00 AM.
3. Set Station Run Times Run Times can be set from one minute up to six hours.
Turn the dial to Run Times a Press Program Select to choose the desired Program (if necessary).
b Press or to select a Station.
c Press or to set the Run Time for the selected Station.
d Press to set additional Station Run Times.
B NOTE: Only assign Run Times in a Program for stations you want to water. If you do not want a specific station to run in a selected program then set the Run Time to zero.
B NOTE: Rain Bird recommends that the maximum irrigation station cycle time be less than the time required for runoff to begin and that there be adequate soak time before the next irrigation cycle of that same station begins again.
4. Set Water Days Custom Days of the Week
Set watering to occur on specific days of the week.
Turn the dial to Water Days a Press Program Select to choose the desired Program (if necessary).
b Press or to set the selected (blinking) day as either ON or OFF, and to automatically move to the next day.
c Press or at any time to move the cursor to the previous or next day.
B NOTE: With Sunday selected, press the button to enter and activate Cyclic Watering (see the Advanced Programming section). If this is not desired, press the button to return to watering by Custom Days.
ESP-ME3 Controller11
EN Program-Based Scheduling The ESP-ME3 uses a programmed-based scheduling method to create irrigation schedules. This means all stations with a run time on the program will run in numerical order.
Common Programming Error The most common programming error for any pro-gram-based controller is to set multiple Program Start Times that cause watering cycles to repeat.
As an example: Program A has a 1st Start Time set to run at 8:00 AM. But then a 2nd Start Time has mistak-enly been set for 8:15 AM, which means that all sta-tions would water a 2nd time.
In this example, a 3rd Start Time has mistakenly been set for 8:30 AM. Which means all stations would water a 3rd time. The desired watering time was 45 minutes, or 15 minutes per station. The actual is 2 hours and 15 minutes, which is excessive watering!
Incorrect: Multiple Start Times set by mistake
Program Letter
Program Watering
Time
Program Start Time
Station Number
Station Watering Duration
A 1st 8:00 AM
1 15 MIN
2 15 MIN
3 15 MIN
A 2nd 8:15 AM
1 15 MIN
2 15 MIN
3 15 MIN
A 3rd 8:30 AM
1 15 MIN
2 15 MIN
3 15 MIN
Correct: Only one Start Time
Program Letter
Program Watering
Time
Program Start Time
Station Number
Station Watering Duration
A 1st 8:00 AM
1 15 MIN
2 15 MIN
3 15 MIN
4 15 MIN
Manual Watering Options Test All Stations
Start watering immediately for all programmed stations.
Turn the dial to Manual Watering a Press or to set a Run Time.
b Press the Hold to Start button.
c Turn the dial to AUTO after display shows
STARTED.
During Testing:
The display shows a blinking sprinkler symbol, the active Station Number and the remaining Run Time.
d To cancel the test, turn the dial to OFF for three seconds until the screen shows OFF.
Run a Single Station Start watering a single station, or set multiple stations to water in order.
Turn the dial to Manual Watering a Press or to select the desired station.
b Press – or + to set a Run Time.
c Press the Hold to Start button.
d Irrigation will begin and STARTED will appear on the display.
e Turn the dial back to AUTO
H REPEAT process as desired to add more stations to the queue. When one station finishes watering then the next station will start.
B NOTE: Manual Watering (Test All, Run Single Sta-tion and Manual Program) will start even when a weather sensor is set to SENS ON (sensor on).
ESP-ME3 Controller12
EN Run a Single Program Start watering immediately for one program.
Turn the dial to AUTO.
a Press Program Select to choose the desired Program (if necessary).
b Press the Hold to Start button to begin watering the selected Program.
c Irrigation will begin and STARTED will appear on the display.
d Press the Advance Station button to advance to the next station if desired.
e NOTE: A maximum of 88 stations can be queued across all four programs.
During Manual Watering (Single-station or Single-program):
The display shows a blinking sprinkler symbol, the active Station Number, and the remaining Run Time.
• To cancel manual watering, turn the dial to OFF for three seconds until the screen shows OFF.
To add additional programs to the manual watering queue:
Turn the dial to Manual Watering a Press and hold Program Select to show program letter on the display.
b Press Program Select to choose the desired program (if necessary).
c Press the Hold to Start button to begin watering the selected program.
d Turn the dial to AUTO
Advanced Programming Odd or Even Calendar Days
Set watering to occur on all ODD or EVEN calendar days.
Turn the dial to Water Days a Press Program Select to choose the desired Program (if necessary).
b Press and hold and until ODD or EVEN is displayed.
Cyclic Days Set watering to occur at specific intervals, such as every 2 days, or every 3 days, etc.
Turn the dial to Water Days a Press Program Select to choose the desired Program (if necessary).
b On the Custom Days of the Week screen, press until the Cyclic screen is displayed (after SUN).
c Press or to set the desired DAY CYCLE, then press .
d Press or to set the DAYS REMAINING before the cycle begins. The NEXT watering day updates on the display to indicate the day that watering will start as shown.
B NOTE: See Special Features to set Rain Sensor ON by Station.
ESP-ME3 Controller13
EN Seasonal Adjust Increase or decrease program run times by a selected percentage (5% to 200%).
As an example: If the Seasonal Adjust is set to 100% and the station Run Time is programmed for 10 min-utes, the station will run for 10 minutes. If the Seasonal Adjust is set to 50%, the station will run for 5 minutes.
Turn the dial to Seasonal Adjust.
a Press or to increase or decrease Seasonal Adjust for all Programs.
b To adjust an individual Program, press Program Select to choose the desired Program (if necessary). Press or to increase or decrease Seasonal Adjust for all Programs.
Delay Watering Suspend watering for up to 14 days.
Turn the dial to AUTO.
a Press and Hold the button to enter the Rain Delay screen.
b Press or to set the DAYS REMAINING. The NEXT watering day will update on the display to indicate when watering will resume.
c To cancel a Rain Delay, set the DAYS REMAINING back to 0.
B NOTE: When the delay expires, automatic irriga-tion resumes as scheduled.
Permanent Days Off Prevent watering on selected days of the week (for Odd, Even or Cyclic programming only).
Turn the dial to Water Days a Press Program Select to choose the desired Program (if necessary).
b Press and hold Program Select, then press to set the selected (blinking) day as a Permanent Day Off or press to leave the day ON.
ESP-ME3 Controller14
EN Special Features a Turn the dial to the desired position indicated below for each Special Feature.
b Press and hold and at the same time.
Set Interstation Delay by Program
A station delay (from 1 second to 9 hours) ensures that a valve has completely closed before the next one opens. Press Program Select to set delay for different programs.
Set Rain Sensor by Station
Tells a station to obey or ignore a rain sensor.
Save Programming
Restore Programming
Set Master Valve by Station
Allows a station to be controlled by a master valve or pump start relay.
Set to Odd or Even Watering Days
Options Reset Button
If the controller is not working properly, you can try pressing RESET.
• Insert a small tool such as a paper clip, into the access hole and press until the controller is reset.
All previously programmed watering schedules will remain stored in memory.
RESET
Remote Accessories A 5 pin accessory port is available for Rain Bird approved external devices, including:
• LNKTM WiFi Module
• LIMR Receiver Quick Connect harness
PORT
Set Flow Sensor by Station
Turns a flow sensor on or off by station
Reset to Factory Defaults All programmed schedules will be erased.
ESP-ME3 Controller15
EN Detached Programming Program the front panel remotely on battery power.
The front panel can be removed from the controller and programmed remotely using a 9 volt battery for power. Settings can be programmed for all 22 stations regardless of which Station Modules are installed in the controller.
a Remove the front panel.
b Install a 9V battery in the battery compartment.
c Program the controller.
B NOTE: Program information is stored in nonvol-atile memory so it is never lost if the front panel loses power.
d Replace the front panel (refer to Complete Installation in the Installation section).
B NOTE: After the front panel is re-installed, any station that does not have a corresponding Sta-tion Module installed will function as though the run time is zero.
Battery Life If the display repeatedly shows “-- -- -- -- --”, or there is no display when using a 9V battery for remote pro-gramming, replace the battery.
Appendix Troubleshooting Error Detection
The ESP-ME3 controller has built-in error detection that can automatically generate an ALARM caused by an essential programming error or if an electrical short condition is detected.
The ALARM LED light on the ESP-ME3 controller front panel will light up to indicate an alarm condition:
Programming Errors (blinking LED)
Error
ALARM
LED
Error Mes-sage On Display
No Start Times are set BLINK NO START TIMES
No Run Times are set BLINK NO RUN TIMES
No Water Days are set BLINK NO WATER DAYS
The error will go away when the station is successfully run after condition is corrected.
B NOTE: The dial must be in the AUTO position for an ALARM message to appear on the display.
Electrical Errors (non-blinking LED)
Error
ALARM
LED
Error Message
On Display Master Valve short
SOLID MASTER VALVE SHORTED
OR HIGH CURRENT
Station short SOLID STATION “X” WIRE SHORT-
ED
When an electrical error is detected, irrigation for the affected station is cancelled and watering advances to the next operable station in the program.
The controller will attempt to water the affected sta-tion again at the next scheduled watering. Completion of a successful watering will clear the error condition associated with that station.
ESP-ME3 Controller16
EN
Watering Issues
Problem Possible Cause Possible Solution Display shows a program is active, but system isn’t watering.
Water source not supplying water. Verify there is no disruption to the main water line and that all other water supply lines are open and functioning properly.
Wiring is loose or not properly connect-ed.
Check that field wiring and master valve or pump start relay wiring is securely connected at the controller and in the field.
Field wires are corroded or damaged. Check field wiring for damage and replace if necessary.
Check wiring connections and replace with watertight splice connectors if needed.
Loss of AC power. When there is a power loss and a 9 volt battery is in-stalled, the system does not irrigate but programs show as remaining active.
NO AC message on display.
No Power detected. Check circuit breaker and that unit is plugged into socket or properly connected to power source.
Controller may be plugged into a GFCI outlet or an outlet that is wired to a GFCI outlet.
Check power to the outlet or reset the circuit breaker.
It just rained and the alarm light is not illuminated, why?
This is normal operation. The ESP-ME3 does not consider the interruption of irrigation due to rainfall as an alarm condition.
This is normal operation.
Flow Alarms
Error
ALARM
LED
Error Message
On Display Flow Sensor - High Flow Con-dition
Solid HIGH FLOW ALARM STA-
TION "X"
Flow Sensor - Low Flow Con-dition
Solid LOW FLOW ALARM STA-
TION "X"
When a flow sensor is in use the ESP-ME3 monitors for High Flow of 130% above regular learned flow. This percent limit can be adjusted in the Rain Bird App when used with LNKTM WiFi Module. If a High Flow con-dition is detected, a “High Flow Alarm” is shown at the display and the red alarm LED comes on. To clear the alarm press the “Hold to Start” right arrow button dur-ing the alarm message.
Low Flow conditions are also monitored. The limit for Low Flow is 70% below the learned flow unless changed in the Rain Bird App. A Low Flow alarm is shown at the controller display and the red alarm LED comes on.
To clear the alarm press the “Hold to Start” right arrow button during the alarm message.
B NOTE: Turning the flow sensor feature off and then back on will cause the controller to learn new flow levels and ignore previous error condi-tions.
B NOTE: If the flow sensor measures flow when the controller is not scheduled for watering, a “HIGH FLOW ZONE” alarm is shown on the display and the red alarm LED comes on. To clear the alarm press the “Hold to Start” right arrow button dur-ing the alarm message.
ESP-ME3 Controller17
EN Watering Issues
Problem Possible Cause Possible Solution Programmed sched-ules do not start.
Connected rain sensor may be activat-ed.
Set Rain Sensor to Sensor OFF to ignore the rain sensor.
If watering resumes, the sensor is operating properly and no further correction is needed.
Connected rain sensor may not be oper-ating properly.
Let the rain sensor dry out, or disconnect it from the controller terminal strip and replace it with a jumper wire connecting the two SENS terminals, or set to Sensor OFF.
If no rain sensor is connected, the jumper wire connecting the two SENS terminals on the terminal strip may be missing or damaged.
Move dial position to Weather Sensors and set to Sensor
OFF.
Too much irrigation Multiple Start Times in the same pro-gram.
Separate start times are not required for each valve. A program only requires single start time in order to run all stations in that program.
Multiple programs are running at the same time.
Review programming to assure that the same Station is not active in multiple Programs.
Valve is malfunctioning. Check to see if the ALARM light on the controller is lit solid, then repair or replace the valve if necessary.
Seasonal Adjust setting is too high. Set Seasonal Adjust to 100%.
Electrical Issues (solid LED illuminated)
Problem Possible Cause Possible Solution Display is blank or fro-zen, the controller will not accept program-ming or is operating abnormally.
Power not reaching the controller.
Verify the main AC power supply is securely plugged in or connect-ed and working properly.
Controller needs to be reset. Press the Reset Button. For details see “Reset Button” section.
An electrical surge may have interfered with the control-ler’s electronics.
Unplug the controller for 2 minutes, then plug it back in. If there is no permanent damage, the controller should accept programming and resume normal operation.
Automatic error detec-tion indicates a problem by ALARM LED and an error message on display.
Short circuit or overload condition in valve, master valve or pump start relay wiring.
Identify and repair the fault in the wiring. Refer to compatible pump start relays. For details see “Connect Pump Start Relay” section.
LED is flashing or solidly illuminated but I see no message on the LCD.
Dial not in AUTO RUN position.
Turn dial to AUTO RUN position. Push Reset button or power cycle the controller.
ESP-ME3 Controller18
EN Safety Information
CWARNING
Special precautions must be taken when valve wires (also known as station or solenoid wires) are locat-ed adjacent to, or share a conduit with other wires, such as those used for landscape lighting, other “low voltage” systems or other “high voltage” power.
Separate and insulate all conduc-tors carefully, taking care not to damage wire insulation during installation. An electrical “short” (contact) between the valve wires and another power source can damage the controller and create a fire hazard.
All electrical connections and wiring runs must comply with local build-ing codes. Some local codes require that only a licensed or certified electrician can install power. Only professional personnel should in-stall the controller. Check your local building codes for guidance.
Outdoor controller shall be permanently connected to fixed wiring by a flexible cord, and have a cord anchorage. The cord anchorage shall relieve conductors from strain, including twisting, at the terminals and protect the insulation of the conductors from abrasion.
CCAUTION
Stationary appliances not fitted with means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under overvolt-age category III, the instructions state that means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules
This appliance can be used by chil-dren aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
For controllers not provided with supply cord, the fixed installation must include a dis-connecting device for all three poles suitable for overvoltage category III protection.
NOTICE
Use only Rain Bird approved accessory devices. Unapproved devices may damage the controller and void the warranty. For a list of compatible devices go to: www.
rainbird.com
Changes or modifications not ex-pressly approved by Rain Bird could void the user’s authority to operate the equipment.
Date and time are retained by a lithium battery which must be disposed of in accordance with local regulations.
Certifications
Supplier’s Declaration of Conformity 47 CFR § 2.1077 Compliance Information
Unique Identifier: ESP-ME3 (ESP4ME3)
Responsible Party – U.S. Contact Information
Rain Bird Corporation 9491 Ridgehaven Court San Diego, CA 92123 Ph. (858) 268-2650
FCC Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harm-ful interference, and (2) this device must accept any interference received, including interfer-ence that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B dig-ital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a res-idential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interfer-ence to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equip-ment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
• Changes or modifications not expressly approved by Rain Bird could void the user’s authority to operate the equipment.
ICES-003 Compliance Label/Étiquette de conformité à la NMB-003
CAN ICES-3(B)/NMB-3(B)
The Intelligent Use of Water®
LEADERSHIP · EDUCATION · PARTNERSHIPS · PRODUCTS
At Rain Bird, we believe it is our responsibility to develop products and technologies that use water efficiently. Our commitment also extends to education, training and services for our industry and community.
The need to conserve water has never been greater.
We want to do even more and with your help we can.
Visit www.rainbird.com for more information about The Intelligent Use of Water®.
Rain Bird Corporation 6991 East Southpoint Road
Tucson, AZ 85756
USA
Tel: (520) 741-6100
Rain Bird Turkey Çamlık Mh. Dinç Sokak Sk. No.4 D:59-60
34760 Ümraniye, İstanbul
TÜRKIYE
Tel: (90) 216 443 75 23 rbt@rainbird.eu www.rainbird.com.tr
Rain Bird Ibérica S.A.
C/ Valentín Beato, 22 2ª Izq. fdo
28037 Madrid
ESPAÑA
Tel: (34) 91 632 48 10 rbib@rainbird.eu · www.rainbird.es portugal@rainbird.eu www.rainbird.pt
Rain Bird Corporation 970 W. Sierra Madre Ave.
Azusa, CA 91702
USA
Tel: (626) 812-3400
Rain Bird Europe SNC Rain Bird France SNC
240 rue René Descartes Bâtiment A, parc Le Clamar
BP 40072
13792 AIX-EN-PROVENCE CEDEX 3
FRANCE
Tel: (33) 4 42 24 44 61 rbe@rainbird.eu · www.rainbird.eu rbf@rainbird.eu · www.rainbird.fr
Rain Bird Australia Pty Ltd.
Unit 13, Level1
85 Mt Derrimut Road PO Box 183
Deer Park, VIC 3023 Tel: 1800 724 624 info@.rainbird.com.au www.rainbird.com/au
Technical Services for U.S. and Canada only:
1 (800) RAINBIRD
1-800-247-3782 www.rainbird.com
Rain Bird International 1000 W. Sierra Madre Ave.
Azusa, CA 91702
USA
Tel: +1 (626) 963-9311
Rain Bird Deutschland GmbH Königstraße 10c 70173 Stuttgart
DEUTSCHLAND
Tel: +49 (0) 711 222 54 158 rbd@rainbird.eu
Rain Bird Brasil Ltda.
Rua Marques Póvoa, 215 Bairro Osvaldo Rezende Uberlândia, MG, Brasil
CEP 38.400-438
Tel: 55 (34) 3221-8210 www.rainbird.com.br
) Registered trademark of Rain Bird Corporation ( 2020 Rain Bird Corporation D41274 15JA20
Frazier Engineering, Inc. • 6767 North Wickham Road, Suite 304, Melbourne, FL 32940 • 321-253-8131
- Division 10: Scoreboard
ELECTRO-MECH SCOREBOARD CO.
1030 BASEBALL SCOREBOARD
OWNER’S HANDBOOK
Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that your new scoreboard will give many years of reliable service.
Rev. 3 Revised:07/12/2007
Electro-Mech Scoreboard Co. 120 Industrial Parkway Wrightsville, GA 31096 Phone: (800) 445-7846 Fax (478) 864-0212 Email: score@electro-mech.com
1030 Page 2
TABLE OF CONTENTS
SCOREBOARD SPECIFICATIONS
SCOREBOARD INSTALLATION
MECHANICAL INSTALLATION
Post Installation Mounting The Scoreboard
MOUNTING HARDWARE
Mounting The Optional Top Sponsor Panel
ELECTRICAL INSTALLATION
Ground Connection Power Connections
SL-230 / 330
Control Cable Installation Control Console Connections Control Console Safety Warning
SCOREBOARD OPERATION
SCOREBOARD STARTUP
GAME TIME OPERATION
SCOREBOARD SHUTDOWN
SERVICING THE SCOREBOARD
COMPONENT REPLACEMENT
LED Digits And Indicators Replacement LX Driver Board Replacement LED Power Supply Module Replacement
WARRANTY
Electro-Mech Scoreboard Co. 120 Industrial Parkway Wrightsville, GA 31096
1030 Page 3
SCOREBOARD SPECIFICATIONS
GENERAL: This ETL listed scoreboard includes the scoreboard cabinet, mounting hardware, control console, 10 ft. extension cable, and junction box.
DIMENSIONS: 8’ L x 4’” H x 6” D; 1030 with side ad panel: 12’ L x 5’ H x x6”D; 1030 with two side ad panels: 16’ L x 5’ H x 6” D
WEIGHT: 110 lbs; 1030 with side ad panel: 205 lbs; 1030 with two side ad panels: 250 lbs
SCOREBOARD CONSTRUCTION: The outer frame is made from extruded aluminum. Internal structural parts may be extruded aluminum or formed from aluminum sheet. The face and back are made from aluminum sheet. The face and masks are finished with enamel paint. Black is the standard color. The captions are white.
DISPLAY: The 1030 baseball scoreboard displays HOME and GUEST scores to 99, INNINGS (INN) to 9, BALLS (BALL), STRIKES (STRIKE), and OUTS (OUT).
DIGITS AND INDICATORS: Red light emitting diodes mounted on printed circuit boards form the digits and indicators. The digits are 18” tall. Circular clusters of light emitting diodes form the 4” diameter BALLS, STRIKES, and OUTS indicators.
POWER REQUIREMENTS: Scoreboard - 120 VAC, 1 A, 60 Hz Control Console - 120 VAC, 0.5 A, 60 Hz
SCOREBOARD ELECTRONICS: 100% solid state fully enclosed.
CONTROL CONSOLE: The control console features a microprocessor, 15 key sealed membrane keypad and an attached 6 foot power cord. The console housing consists of ABS plastic base and top pieces with a steel back plate.
CONTROL CABLE: The cable has two 22 AWG stranded copper conductors with semi-rigid PVC insulation. It also has a braided shield and a foil shield. The polyethylene jacket is rated at 300 volts. The cable is direct burial rated and measures approximately ¼” in diameter. This item is sold separately from the scoreboard.
JUNCTION BOX AND EXTENSION CABLE: A 4 ¼” x 2 ¼” x 2” junction box with a ¼” stereo jack mounted on the face plate is attached to the control cable at the point of operation. A 10 ft.
extension cable connects the control console to the junction box.
SL-230 / 330 RF MODEM SYSTEM: This accessory can be used in place of control cable and junction box for this scoreboard. Refer to the SL-230 / 330 RF MODEM INSTALLATION MANUAL for more information.
WARRANTY: Five year limited warranty.
Electro-Mech Scoreboard Co. 120 Industrial Parkway Wrightsville, GA 31096
1030 Page 4
SCOREBOARD INSTALLATION
This part of the manual describes the mechanical and electrical installation of the scoreboard.
One of the items listed below must be purchased in order to complete the installation:
Control cable (length dependent upon installation site layout) SL-230 / 330 RF Modem System
Items not provided by Electro-Mech Scoreboard Company that are necessary for installation:
Two posts Power cable to connect the scoreboard to the power source Grounding hardware A grounded NEMA 5-15R 120 VAC receptacle for the control console at the scorekeeper’s table.
Items not provided that are recommended by Electro-Mech Scoreboard Company for installation:
A weatherproof power disconnect at the scoreboard
Electro-Mech Scoreboard Company performs installations in some areas. In other areas, we can help you contact an independent installer. In areas in which installation service is not available from Electro-Mech Scoreboard Company, we will make every effort to answer your installation questions. Qualified personnel should perform the scoreboard installation. Consult national and local codes before installation.
MECHANICAL INSTALLATION
The mechanical installation includes installing the posts and mounting the scoreboard and the optional top sponsor panels (if purchased) to the posts.
Post Installation
The scoreboard mounts on two posts. Typically installers will use steel pipes or I-beams.
In order to reduce the glare from the sun on the front of the scoreboard, position the posts so that the front of the scoreboard is angled away from the afternoon sun, if possible.
The mounting hardware will accommodate posts up to 4.5 inches outer diameter. Sink the posts in reinforced concrete footings. Figure 1 shows the spacing of the posts for a 1030 scoreboard. The specifications for the posts and concrete footings are dependent upon the expected local wind and soil conditions, the height of the scoreboard from the ground, and the local building codes. Electro-Mech Scoreboard Company assumes no responsibility for the installation of scoreboards by others.
Electro-Mech Scoreboard Co. 120 Industrial Parkway Wrightsville, GA 31096
1030 Page 5
5/8" BRASS TEAR DROP CONNECTOR
#6 BARE COPPER GROUND WIRE
8' 5'
4'
10'
5/8" x 8' COPPER CLAD GROUND ROD
POWER
DISCONNECT
POWER CABLE
IN 3/4" CONDUIT
CONTROL
CABLE IN 3/4"
CONDUIT
TO CONTROL LOCATION
TO POWER SOURCE
Figure 1 1030 Post Spacing
Figure 2 shows the spacing of the posts for a 1030 scoreboard with an optional top sponsor panel. This panel is a separate unit that mounts on the same posts as the scoreboard.
Electro-Mech Scoreboard Co. 120 Industrial Parkway Wrightsville, GA 31096
1030 Page 6
5/8" BRASS TEAR DROP CONNECTOR
#6 BARE COPPER GROUND WIRE
8' 5'
4'
10'
5/8" x 8' COPPER CLAD GROUND ROD
POWER
DISCONNECT
POWER CABLE
IN 3/4" CONDUIT
CONTROL
CABLE IN 3/4"
CONDUIT
TO CONTROL LOCATION
TO POWER SOURCE
Figure 2 1030 with Optional Top Sponsor Panel Post Spacing
Figure 3 shows the spacing of the posts for a 1030 scoreboard with optional bottom and side sponsor panels built into the scoreboard frame.
Electro-Mech Scoreboard Co. 120 Industrial Parkway Wrightsville, GA 31096
1030 Page 7
8'
5'
10'
5/8" BRASS TEAR DROP CONNECTOR
#6 BARE COPPER GROUND WIRE
5/8" x 8' COPPER CLAD GROUND ROD
POWER
DISCONNECT
POWER CABLE
IN 3/4" CONDUIT
CONTROL
CABLE IN 3/4"
CONDUIT
TO CONTROL LOCATION
TO POWER SOURCE
Figure 3 1030 with Optional Bottom and Side Sponsor Panels Post Spacing
Figure 4 shows the spacing of the posts for a 1030 scoreboard with two side sponsor panels and a bottom sponsor panel built into the scoreboard frame.
Electro-Mech Scoreboard Co. 120 Industrial Parkway Wrightsville, GA 31096
1030 Page 8
5'
10'
16'
10'
5/8" BRASS TEAR DROP CONNECTOR
#6 BARE COPPER GROUND WIRE
5/8" x 8' COPPER CLAD GROUND ROD
POWER
DISCONNECT
POWER CABLE
IN 3/4" CONDUIT
CONTROL
CABLE IN 3/4"
CONDUIT
TO CONTROL LOCATION
TO POWER SOURCE
Figure 4 1030 with Optional Bottom and Two Side Sponsor Panels Post Spacing
Mounting The Scoreboard
The scoreboard is attached to the posts at four points. Figure 5 shows the location of the mounting points on the rear of the scoreboard.
Electro-Mech Scoreboard Co. 120 Industrial Parkway Wrightsville, GA 31096
1030 Page 9
MOUNTING POINT #1 MOUNTING POINT #2
MOUNTING POINT #3 MOUNTING POINT #4
ELECTRO-MECH SCOREBOARD CO.
ANSI/UL-143 3 & ANSI/UL -48
Check with the applicable sta te and local codes befor e instal lation
#3 Industrial Par kway P.O. Box 102 Wrights vil le , GA 31096-0102
Replace with 15 W lamp, maximum power before servicing equipment Electric shock hazard: Dis connect
Model No. MM-1000 Serial No. AB- Date of Mfg.
120 VAC 60 Hz 13.3 A No. of lampholders 107
CAUTION
ETL LI STED
EL ECTRI C SIGNS AND
CO NT RO L CENT ERS F OR
CHANGI NE MESSAGE T YPE
ELECT RIC SIGNS
R
LIS DET
45236
US
CO NFORMS TO
Figure 5 Mounting Points
MOUNTING HARDWARE
Four sets of mounting hardware are provided to attach the scoreboard at these points.
Additional hardware sets are provided to attach the optional top sponsor panels, if ordered. A single set of mounting hardware consists of a steel angle bracket, two threaded rods, two washers, and two nuts. Figure 6 shows an overhead cross section view and a side cross section view of the scoreboard attached to a post at a mounting point. A steel bar is riveted inside the scoreboard’s aluminum extrusion frame. The bar has two tapped holes. The threaded rods screw into these tapped holes. The washers and nuts are used to clamp the steel angle bracket against the steel post and hold the scoreboard in place.
Electro-Mech Scoreboard Co. 120 Industrial Parkway Wrightsville, GA 31096
1030 Page 10
Side Cross Section ViewOverhead Cross Section View
Nut
1/4-Inch Flat Bar With Tapped Holes
Threaded Rod
Washer Nut
Scoreboard Back
Scoreboard Face
Aluminum Frame Extrusion
1/4-Inch Flat Bar With Tapped Holes
4-Inch Steel Post
Steel Angle Bracket
4-Inch Steel Post
Washer
Steel Angle Bracket
Threaded Rod
Scoreboard Back
Extrusion Lip
Figure 6 Standard Mounting Method
The following steps describe how to mount the scoreboard on the posts:
1. Place the scoreboard cabinet against the posts on the ground. Make sure the mounting points are aligned with the posts.
2. Screw the threaded rods into the tapped holes in the scoreboard.
3. Place a steel angle bracket over the threaded rods at mounting point #1.
4. Place a washer over each threaded rod.
5. Screw the nuts onto the threaded rods so that the bracket is loosely held in place.
6. Repeat steps 3 - 6 at the other mounting points.
7. Raise the scoreboard into place and tighten the nuts to clamp the scoreboard in place on the posts.
Note: Be sure to leave enough space on the posts above the scoreboard for the optional top sponsor panel, if purchased.
Electro-Mech Scoreboard Co. 120 Industrial Parkway Wrightsville, GA 31096
1030 Page 11
Mounting The Optional Top Sponsor Panel
Additional hardware sets are provided to attach the optional top sponsor panels, if purchased. The following steps describe how to mount the top sponsor panel on the posts:
1. Raise the top sponsor panel in place above the scoreboard. Make sure the mounting points are aligned with the posts.
2. Screw the threaded rods into the tapped holes in the top sponsor panel.
3. Place a steel angle bracket over the threaded rods at a mounting point.
4. Place a washer over each threaded rod.
5. Screw a nut onto each threaded rod so that the bracket is loosely held in place.
6. Repeat steps 3 - 5 at the other…