PRODUCT ENGINEERING REQUIREMENTS
The following Item Description, Drawing(s) and/or Specification(s) represent minimum
Government requirements and are applicable to this Procurement.
National Stock Number (NSN): 5180-01-677-6455
Tool Kit, Carpenter’s
In accordance with Army Technical Data Package List (TDPL) 0414A0000:59678, dated 4 June
2019.
With the following exceptions:
Army Drawing 0414B0000, Rev “-“, dated 2018-10-04, Page 2, Zone D3-4 and C3-4, Note 10, REMOVE:
WATER ENTRY RESISTANCE:
WHEN CLOSED AND FASTENED, THE CHEST SHALL WITHSTAND IMMERSION IN WATER,
WITHOUT WATER ENTRY, TO A DEPTH OF NO LESS THAN I METER (3.28 FEETI TO THE
UPPERMOST SURFACE OF THE CHEST FOR NO LESS THAN 30 MINUTES WHEN TESTED IN
ACCORDANCE WITH TEST METHOD 512.6 OF MIL-STD-810 THE CHEST SHALL BE
CONDITIONED SO THAT ITS TEMPERATURE IS NO LESS THAN 27'C (80.6'FI ABOVE THE
WATER TEMPERATURE PRIOR TO IMMERSION. THE CHEST SHALL BE TIED DOWN USING
THE HANDLES, THE TIE DOWN POINTS OR WEIGHTED WITH OTHER LOADED CHESTS
STACKED UPON THE TEST ITEM. PRIOR TO CONDITIONING AND TESTING, THE CHEST
SHALL HAVE BEEN UNLATCHED, OPENED, CLOSED AND RE-LATCHED NO FEWER THAN 10
TIMES. IF A RUBBERIZED SEAL IS USED TO MEET THE REQUIREMENTS, THEN IT SHALL BE
EASILY REPLACED WHEN DAMAGED IN THE FIELD.
And REPLACE WITH:
WATER ENTRY RESISTANCE:
WITH THE TOOL CASE IN A SHUT AND SEALED CONFIGURATION, TAKE A SOURCE OF
WATER FLOWING THROUGH A 0.75” UNRESTRICTED FLEXIBLE LINE (GARDEN HOSE) WITH
A PRESSURE NO LESS THAN 35 POUNDS PER SQUARE INCH AND RUN OVER ALL SEAMS
AND OPENINGS. RUN THE HOSE 12” ± 6” FROM THE TOOL CASE, DIRECTLY INTO THE
SEAMS AND INTO ANY OTHER POSSIBLE LEAK AREAS (E.G. THE HANDLES, WHEELS OR
RIVETS IF PRESENT). RUN THE HOSE OVER THE SEAMS AT A MODERATE SPEED. WIPE
DOWN THE EXTERIOR OF THE TOOL CASE, TO REMOVE ANY EXCESS WATER THAT HAS
POOLED BECAUSE OF THE TEST. EXAMINE THE INTERIOR OF THE TOOL CASE AND
CONFIRM THAT NO WATER HAS ENTERED. WATER ON THE GASKET MATERIAL AND
SEALS IS EXPECTED.
Army Drawing 0414A0001, Rev “-“, dated 2018-10-04, Page 1, Zone C3, END ITEM NSN: 5180-01-499-3548
END ITEM NSN: 5180-01-677-6455
Army Drawing 0414A0001, Rev “-“, dated 2018-10-04, Page 1, Zone C1-2, END ITEM NSN: 5180-01-499-3546
END ITEM NSN: 5180-01-677-6455
Army Drawing 0414A0001, Rev “-“, dated 2018-10-04, Page 1, Zone C1-2, Specification Data: ARDEC TDP 0414A0000:59678
Specification Data: 0414A0000:59678
Army Drawing 0414A0001, Rev “-“, dated 2018-10-04, Page 1, Zone B3-4, Specification Data: ARDEC TDP 0414A0000:59678
Specification Data: 0414A0000:59678