PN79439-2_Drawings_RTA_Vol3of3_Aug-2022 (LOCKED).pdf
PDF 15 MB Posted
- Attached to
- SOF Advanced Skills Training Facility Annex and HAZMAT Facilities Federal contract opportunity
- Solicitation number
- W912PM22R0012
About this file
This document provides details on a federal contract opportunity for construction services. The Army Corps of Engineers, Wilmington District is seeking to issue a solicitation for the construction of an Advanced Skills Training Facility Annex and HAZMAT Facilities located at Fort Bragg, North Carolina. The contractor will be responsible for construction of approximately 24,500 square feet of administrative offices, classrooms, conference rooms, instructional labs, storage areas, and support facilities. An additional 1,200 square foot Hazardous Material Storage building and 350 square feet of open storage area are also included in the project scope. The facilities are to be designed and constructed to a minimum 40-year life in accordance with DoD sustainability and energy efficiency standards. The solicitation number for this opportunity is W912PM22R0012.
View the file
Other files for this federal contract opportunity
Show all 23
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FI
LE
N
AM
E:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
A
M
AR
K
SU
BM
IT
TE
D B
Y:
D
AT
E
C H
EC
KE
D B
Y:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
US Army Corps of Engineers
SI
ZE
"x
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
W
IL
M
IN
G
TO
N D
IS
TR
IC
T
D
AR
LI
N G
TO
N
A
VE
N U
E W
IL
M
IN
G
TO
N
, N O
R
TH
C
AR
O
LI
N A
G-000
C O
VE
R
S H
EE
T
US Army Corps of Engineers ®
Wilmington District
S.
S
U R
R
AT
T
S.
S
U R
R
AT
T
J.
M
AN
N
IN
G
Aw d_
C ov er .d w g
C O
N
TR
AC
T
N O
D R
AW
IN
G C
O D
E:
SO
LI
C
IT
AT
IO
N N
O
W
2P M
R
AW
AR
D D
AT
E:
AU
G
U
ST
W
2P M
XX
XX
A.
F
EL
IC
IA
N
O -G
R
AN
D A
PN79439.2 SOF ADVANCED SKILLS TRAINING FACILITY ANNEX
AND HAZMAT FACILITIES
FORT BRAGG, NORTH CAROLINA
RTA SET
CONTRACT NO.: W912PM22XXXX
SOLICITATION NO: W912PM22R0012
ISSUE DATE: AUGUST 2022
PN
9.
SO
F
AD
VA
N
C
ED
S
KI
LL
S
TR
AI
N
IN
G
FA
C
IL
IT
Y
AN
N
EX
A
N D
H
AZ
M
AT
F
AC
IL
IT
IE
S
FO
R
T
BR
AG
G
, N O
R
TH
C
AR
O
LI
N A
R
TA
S
ET
VOLUME 3 OF 3
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
A
D A
T E
US Army Corps of Engineers ®
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
M A
R K
D E
S C
R
IP
T
IO
N
N
M
IC
H
IG
A
N A
V E
S U
IT
E
C H
IC
A
G O
IL
p ro j.
n o
F
IL
E N
A M
E
205 N. MICHIGAN AVE
SUITE 3800
CHICAGO, IL 60601
P N
VOLUME:
B
C
D
2 3 4 5
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
G-005
G E
N E
R A
L
F O
R T
B R
A G
G N
C W
IL
M
IN
G
T O
N D
IS
T
R
IC
T D
A R
L
IN
G T
O N
A V
E W
IL
M
IN
G
T O
N N
C
K S
H E
R L O
C K
K S
H E
R L O
C K
K S
H E
R L O
C K
P Z
IN
N
I
A U
G
W P
M R
S O
F T
E C
H N
IC
A
L S
U P
P O
R T
T R
A
IN
IN
G
A N
N E
X
WILMINGTON DISTRICT
W912PM22R0012
AUG 2022
C O
V E
R S
H E
E T
V
O L U
M E
O
F
READY TO ADVERTISE
C H
I- -A
A
W P
M F
.r v t
F Y
P
N
.2
F Y
P
N
.2
CONTROLLED BY: USASOC
CONTROLLED BY: USACE SAW
CUI CATEGORYl CONTRACT
DISTRIBUTION STATEMENT D
POC: USACE FOIA (foia-saw@usace.army.mil)
DESIGNATION INDICATOR BLOCK
FORT BRAGG, NORTH CAROLINA
FY22 PN 79439.2, SOF TECHNICAL SUPPORT TRAINING
ANNEX & HAZMAT STORAGE BUILDING,
YARBOROUGH COMPLEX, FORT BRAGG, NC
VOLUME 3 OF 3
MECHANICAL, ELECTRICAL, ESS,
TELECOMMUNICATIONS, AUDIO / VIDEO
ELECTRICAL
8/3/2022
8/3/2022
8/3/2022
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
N
M
IC
H
IG
A
N A
V E
S U
IT
E
C H
IC
A
G O
IL
p ro j.
n
E N
A M
E
P N
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
B
C
D
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
2 3 4 5
G-006
G E
N E
R A
L
F O
R T
B R
A G
G N
C W
IL
M
IN
G
T O
N D
IS
T
R
IC
T D
A R
L
IN
G T
O N
A V
E W
IL
M
IN
G
T O
N N
C
K S
H E
R L O
C K
K S
H E
R L O
C K
K S
H E
R L O
C K
P Z
IN
N
I
A U
G
W P
M R
R E
A D
Y T
O A
D V
E R
T
IS
E
S O
F T
E C
H N
IC
A
L S
U P
P O
R T
T R
A
IN
IN
G
A N
N E
X
IN
D
E X
O F
D R
A W
IN
G
S
V O
L U
M E
O
F
C H
I- -A
A
W P
M F
.r v t
F Y
P
N
.2
F Y
P
N
.2
SHEET
NUMBER
SHEET NAME
TELECOMMUNICATIONS
T-001 LEGEND AND GENERAL NOTES
T-100 TELECOMMUNICATION SITE PLAN
T-101 TELECOMMUNICATIONS PLAN - AREA A
T-102 TELECOMMUNICATIONS PLAN - AREA B
T-401 TELECOMMUNICATIONS ENLARGED PLANS
T-501 TELECOMMUNICATIONS DETAILS
T-502 TELECOMMUNICATIONS DETAILS
T-601 RISER DIAGRAM
T-602 FIBER DISTRIBUTION ONE-LINE DIAGRAM
T-603 TELECOMMUNICATIONS RACK ELEVATIONS - ROOMS A110 (NIPR)
T-604 TELECOMMUNICATIONS RACK ONE-LINE - ROOMS A110 (NIPR)
T-605 TELECOMMUNICATIONS RACK ELEVATIONS - ROOM A112 (SIPR)
AUDIO / VIDEO
TA001 LEGEND AND NOTES
TA101 FIRST FLOOR ENLARGED AV PLAN - AREA A
TA102 FIRST FLOOR ENLARGED AV PLAN - AREA B
TA201 FIRST FLOOR ENLARGED AV RCP - AREA A
TA202 FIRST FLOOR ENLARGED AV RCP - AREA B
TA301 ENLARGED AV PLANS
TA401 DISPLAY ELEVATIONS
TA402 DISPLAY ELEVATIONS
TA501 PLATE & BACK BOX MOUNTING DETAILS
TA502 FLOOR BOX DETAIL
TA503 MOUNTING DETAILS
TA504 CREDENZA AND PODIUM DETAILS
TA541 SIGHT LINE DETAILS
TA561 RACK DETAILS
TA562 RACK DETAILS
TA601 A104 & A106 AV SIGNAL FLOW
TA602 A104 & A106 CONTROL SIGNAL FLOW
TA603 A113, A115, A116 SIGNAL FLOW
TA604 A117 & A118 SIGNAL FLOW
TA605 A121 AV SIGNAL FLOW
TA606 A121 CONTROL SIGNAL FLOW
TA607 A124, A125, A126 SIGNAL FLOW
TA608 A141 & PAGING SYSTEM SIGNAL FLOW
SHEET
NUMBER
SHEET NAME
ELECTRICAL
E-001 LEGEND AND NOTES
EG101 LIGHTNING PROTECTION PLAN
EG102 LIGHTNING PROTECTION HAZMAT BUILDING
EG501 LIGHTNING PROTECTION DETAILS
EG502 MISC GROUNDING DETAILS
EL101 LIGHTING PLAN - AREA A
EL102 LIGHTING PLAN - AREA B
EL103 EXIT LIGHTING PLAN - AREA A
EL104 EXIT AND CATWALK LIGHTING PLAN - AREA B
EL105 LIGHTING PLAN - HAZMAT BUILDING
EL501 LIGHT FIXTURE SCHEDULE AND DETAILS
EL502 LIGHT FIXTURE DETAILS
EL503 LIGHT FIXTURE DETAILS
EL601 LIGHTING CONTROL SCHEDULES AND DIAGRAMS
EL602 LIGHTING CONTROL DIAGRAMS
EP101 POWER PLAN - AREA A
EP102 POWER PLAN - AREA B
EP103 EQUIPMENT PLAN - AREA A
EP104 EQUIPMENT PLAN - AREA B
EP105 HAZMAT BUILDING POWER PLAN
EP401 ENLARGED POWER PLANS
EP402 ENLARGED POWER PLANS
EP601 POWER ONE-LINE DIAGRAM
EP602 MOTOR FEEDER SCHEDULE
EP610 PANEL SCHEDULES
EP611 PANEL SCHEDULES
EP612 PANEL SCHEDULES
EP613 PANEL SCHEDULES
EP614 PANEL SCHEDULES
ELECTRONIC SECURITY SYSTEM
ESS001 DRAWING INDEX
ESS100 SECURITY SITE PLAN
ESS101 SECURITY PLAN - A
ESS102 SECURITY PLAN - B
ESS501 SECURITY DETAILS
ESS502 SECURITY DETAILS
ESS503 SECURITY DETAILS
ESS504 SECURITY DETAILS
ESS601 ACCESS CONTROL RISER
ESS602 VIDEO SURVEILLANCE RISER
ESS701 SECURITY ELEVATIONS
SHEET
NUMBER
SHEET NAME
GENERAL
G-005 COVER SHEET - VOLUME 3 OF 3
G-006 INDEX OF DRAWINGS - VOLUME 3 OF 3
MECHANICAL
M-001 SYMBOLS & ABBREVIATIONS
M-002 GENERAL NOTES & DESIGN CRITERIA
MH100 SITE PLAN
MH101 FIRST FLOOR HVAC PLAN - OVERALL
MH102 FIRST FLOOR HVAC PLAN - AREA A
MH103 FIRST FLOOR HVAC PLAN - AREA B
MH104 FIRST FLOOR HVAC PLAN - AREA C
MH105 FIRST FLOOR HVAC PLAN - OVERALL THERMOSTATS, SENSORS & SWITCHES
MH301 HVAC SECTIONS
MH401 HVAC ENLARGED PLANS
MH402 HVAC ENLARGED PLANS
MH501 HVAC DETAILS
MH502 HVAC DETAILS
MH503 HVAC DETAILS
MH504 HVAC DETAILS
MH505 HVAC DETAILS
MH506 HVAC DETAILS
MH601 HVAC SCHEDULES
MH602 HVAC SCHEDULES
MH603 HVAC SCHEDULES
MH604 HVAC SCHEDULES
MH605 HVAC SCHEDULES
MH701 HOT AND CHILLED WATER PIPING SCHEMATIC DIAGRAM
MP101 HVAC HYDRONIC PIPING PLAN - COMPOSITE
MP102 HVAC HYDRONIC PIPING PLAN - CHWS&R AND CONDENSATE
MP103 HVAC HYDRONIC PIPING PLAN - HWS&R
MI001 HVAC CONTROLS LEGEND
MI002 HVAC CONTROLS SYSTEM - NETWORK SCHEMATIC
MI003 HVAC CONTROLS POINTS - SCHEDULING INSTRUCTIONS
MI801 AHU-1 CONTROL SCHEMATIC DIAGRAM
MI802 AHU-2 CONTROL SCHEMATIC DIAGRAM
MI803 ERV-1 CONTROL SCHEMATIC DIAGRAM
MI804 DOAS-1 CONTROL SCHEMATIC DIAGRAM
MI805 DOAS-2 CONTROL SCHEMATIC DIAGRAM
MI806 DOAS-3 CONTROL SCHEMATIC DIAGRAM
MI807 DOAS-4 CONTROL SCHEMATIC DIAGRAM
MI808 AHU-1 SEQUENCE-OF-OPERATION
MI809 AHU-2 SEQUENCE-OF-OPERATION
MI810 ERV-1 SEQUENCE-OF-OPERATION
MI811 DOAS-1 SEQUENCE-OF-OPERATION
MI812 DOAS-2 SEQUENCE-OF-OPERATION
MI813 DOAS-3 SEQUENCE-OF-OPERATION
MI814 DOAS-4 SEQUENCE-OF-OPERATION
MI815 CONTROL VALVE & DAMPER SCHEDULES
MI816 AHU-1 CONTROL POINTS SCHEDULE
MI817 AHU-2 CONTROL POINTS SCHEDULE
MI818 DOAS-1 CONTROL POINTS SCHEDULE
MI819 DOAS-2 CONTROL POINTS SCHEDULE
MI820 DOAS-3 CONTROL POINTS SCHEDULE
MI821 DOAS-4 CONTROL POINTS SCHEDULE
MI822 ERV-1 CONTROL POINTS SCHEDULE
MI823 MISCELLANEOUS CONTROL SCHEMATIC AND SEQUENCE OF OPERATIONS
MI824 MISCELLANEOUS CONTROL SCHEMATIC AND SEQUENCE OF OPERATIONS
MI825 MISCELLANEOUS CONTROL SCHEMATIC AND SEQUENCE OF OPERATIONS
MI826 MISCELLANEOUS CONTROL SCHEMATIC AND SEQUENCE OF OPERATIONS
MI827 MISCELLANEOUS CONTROL POINTS SCHEDULE
MI828 MISCELLANEOUS CONTROL POINTS SCHEDULE
MI829 MISCELLANEOUS CONTROL POINTS SCHEDULE
MI831 CHILLED WATER SYSTEM CONTROL SCHEMATIC DIAGRAM
MI832 CHILLED WATER CONTROL POINTS SCHEDULE
MI833 HEATING HOT WATER CONTROL POINTS SCHEDULE
MI830 HEATING HOT WATER CONTROL SCHEMATIC DIAGRAM
ELECTRICAL
AIR CONDITION (-ED, -ER, -ING)
AIR COOLED CONDENSER
AIR COOLED CONDENSING UNIT
ABOVE FINISHED FLOOR
AIR FLOW MEASURING STATION
AIR HANDLING UNIT
ANALOG INPUT
ANALOG OUTPUT
ACCESS PANEL
ARCHITECT (-URAL, -URE)
ATMOSPHERE
AUTOMATIC
AUXILIARY
AVERAGE WATER TEMPERATURE
BETWEEN
BOOSTER COIL
BACK DRAFT DAMPER
BACKFLOW PREVENTER
BRAKE HORSE POWER
BOTTOM OF DUCT
BOTTOM OF PIPE
BRITISH THERMAL UNITS
BRITISH THERMAL UNITS (THOUSANDS)
COMPRESSED AIR
CAPACITY
CATCH BASIN
CABLE CHASE
CUBIC FEET PER MINUTE
CABINET HEATER
CHILLED WATER RETURN
CHILLED WATER SUPPLY
CAST IRON
CLASS
CLEANOUT, CARBON MONOXIDE
COLUMN
COMPRESSOR
CONDENS(-ER, -ING, -ATION, -ATE)
CONNECT (-ION)
CONTINU(-E, -ATION, -OUS)
CONTROL PANEL, CONDENSATE PUMP
CONDENSATE RETURN
CIRCUIT SETTER
COOLING TOWER
CEILING TRANSFER GRILLE
COEFFICIENT, VALVE FLOW
CONSTANT VOLUME, CONTROL VALVE
COLD WATER
COLD WATER PUMP
CONDENSER WATER RETURN
CONDENSER WATER SUPPLY
DRY-BULB
DUCT DETECTOR
DIRECT DIGITAL CONTROL
DIGITAL INPUT
DIAMETER
DISCONNECT
DIVISION
DOWN
DIGITAL OUTPUT
DEW POINT
DIFFERENTIAL PRESSURE TRANSMITTER
DOWNSPOUT, DUCT SILENCER
DOOR TRANSFER GRILLE
DRAWING
DIRECT EXPANSION
EXISTING
EACH
ENTERING AIR TEMPERATURE
EXHAUST FAN
EFFICIEN(-T, -CY)
ENTERING
ELECTRIC TO PNEUMATIC
EQUIPMENT
EXTERNAL STATIC PRESSURE
EXPANSION TANK
ELECTRIC UNIT HEATER
EVAPORAT(-E, ING, -ED, -PR)
ELECTRIC WATER COOLER
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FIRE ALARM
FIRE ALARM GONG
FIRE ALARM PANEL
FLOOR CLEANOUT
FAN COIL UNIT
FIRE DAMPER / FLOOR DRAIN
FIRE DEPARTMENT CONNECTION
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FIRE HOSE
FIRE HOSE CABINET
FIRE HOSE RACK
FIRE HYDRANT
FIXTURE
FULL LOAD AMPS
FUEL OIL RETURN
FUEL OIL SUPPLY
FEET PER MINUTE
FEET PER SECOND
FLOW SWITCH
FREEZE STAT
FEET
FIN TUBE RADIATION
GALVANIZED
GENERAL CONTRACTOR
GALLONS PER HOUR
GALLONS PER MINUTE
GALLONS PER SECOND
HOSE BIBB
HEATING COIL
HEAD
HAND EXPANSION VALVE
HEAT GAIN, HOT GAS, MERCURY
HORSEPOWER, HIGH POINT
HUMIDITY RATIO, HOUR
HEIGHT
HEATING
HEATER
HOT WATER HEATING
HEATING/VENTILATING/AIR CONDITIONING
HOT WATER PUMP
HOT WATER RETURN
HOT WATER SUPPLY
HYDRAULIC
HERTZ
INSIDE DIAMETER
INVERT ELEVATION
INCHES
INCREASE(-R)
KILOWATTS
LOUVER
LEAVING AIR TEMPERATURE
LAVATORY
POUNDS
LINEAR FEET
LATENT HEAT
LATENT HEAT GAIN
LINEAR
LIQUID
LOW LIMIT
LOG MEAN TEMPERATURE DIFFERENCE
LOW PRESSURE STEAM
LEAST TEMPERATURE DIFFERENCE
LEAVING
LOUVER
LEAVING WATER TEMPERATURE
METER, MOTOR
MIXED AIR
MIXED AIR TEMPERATURE
MAXIMUM
BRITISH THERMAL UNITS (THOUSANDS)
MOTOR CONTROL CENTER
MOTORIZED DAMPER
MEAN EFFECTIVE TEMPERATURE
MINUTES, MINIMUM
MEDIUM PRESSURE
MEDIUM PRESSURE CONDENSATE
MEDIUM PRESSURE STEAM
MEAN TEMPERATURE DIFFERENCE
MAKE-UP
MOTOR-OPERATED VOLUME DAMPER
MAXIMUM WORKING PRESSURE
NOT APPLICABLE
NORMALLY CLOSED, NOISE CRITERIA
NATURAL GAS
NOT IN CONTRACT
NECK
NORMALLY OPEN, NUMBER
OUTSIDE AIR
OPPOSED BLADE DAMPER
OUTSIDE DIAMETER
OUTSIDE SCREW & YOKE (VALVE)
OUTLET VELOCITY
OPEN WASTE
PARALLEL BLADE DAMPER
POUNDS PER CUBIC FOOT
PUMPED CONDENSATE
POUNDS PER CUBIC FOOT
PRESSURE DROP
PNEUMATIC TO ELECTRIC
PHASE
PREHEAT COIL
PRESSURE INDICATOR
PACKAGE(D)
PNEUMATIC
PANEL
PARTS PER MILLION
PRESSURE
PRESSURE REDUCING VALVE
POUNDS PER SQUARE INCH
POUNDS PER SQUARE INCH GAGE
PILOT SOLENOID VALVE
PRE-WIRED
QUART
QUANTITY
RETURN AIR
RADIAT(-E, -ION, -OR)
ROOF DRAIN
RECIRCULATE
REFRIGERANT
REGISTER
RETURN
RELATIVE HUMIDITY
REHEAT COIL
REFRIGERANT LIQUID
REDUCED PRESSURE BACKFLOW PREVENTER
REVOLUTIONS PER MINUTE
REVOLUTIONS PER SECOND
REFRIGERANT RELIEF
REFRIGERANT SUCTION
RESISTANCE TEMPERATURE DETECTOR
SHEET METAL
SUPPLY AIR
SATURATE, SUPPLY AIR TEMPERATURE
CFM, STANDARD CONDITIONS
SMOKE DETECTOR, STORM DRAIN
SQUARE FEET
SENSIBLE HEAT
SENSIBLE HEAT GAIN
SHEET
STATIC PRESSURE, SUMP PUMP
SPECIFIC GRAVITY
SPRINKLER
STATIC PRESSURE TRANSMITTER
SPECIFIC VOLUME
STAINLESS STEEL, SERVICE SINK
STANDARD
SYSTEM
THERMOSTAT, TANK
TESTING, ADJUSTING, AND BALANCING
TOP ANGULAR UP
TEMPERATURE CONTROL CONTRACTOR
TEMPERATURE CONTROL PANEL
TEMPERATURE DIFFERENCE
TEMPERATURE INDICATOR
TRANSFER
TOTAL STATIC PRESSURE
TEMPERATURE TRANSMITTER
TYPICAL
HEAT TRANSFER COEFFICIENT
UP BLAST
UNDER DOOR CUT 1” TR
UNIT HEATER
UNLESS NOTED OTHERWISE
URINAL
VENT, VOLTS
VACUUM
VARIABLE AIR VOLUME
MANUAL VOLUME DAMPER
VELOCITY
VALVE
VELOCITY PRESSURE TRANSMITTER
VENT THRU ROOF
WASTE, WIDTH, WATTS
WITH
WITHOUT
WET-BULB
WATER COLUMN
WATER HEATER, WALL HUNG
WATER
GATE VALVE (OR OTHER TYPE VALVE
WHERE SPECIFIED)
GLOBE VALVE
CHECK VALVE
3-WAY VALVE
3-WAY PNEUMATIC CONTROL VALVE
3-WAY PNEUMATIC CONTROL
VALVE WITH POSITIONER
4-WAY VALVE
RELIEF VALVE
PRESSURE REDUCING VALVE
CONTROL VALVE-ELECTRONIC
CONTROL VALVE-SOLENOID
STRAINER
THERMOMETER & SEPARABLE SOCKET
PRESSURE GAUGE W/ GAUGE COCK
DIAPHRAGM VALVE
ANGLE VALVE-VERTICAL
TEMPERATURE SENSOR
UNION
BALANCING VALVE
CIRCUIT SETTER
PLUG VALVE
NEEDLE VALVE
BUTTERFLY VALVE
BALL VALVE
PIPE RUN UP
PIPE RUN DOWN
PIPE DROP
FLOW DIRECTION
PITCH DIRECTION
COMPRESSED AIR
PIPE ANCHOR
PIPE GUIDE
EXPANSION JOINT
EXPANSION LOOP
FLEXIBLE CONNECTION
REDUCER, CONCENTRIC
REDUCER, ECCENTRIC
AIR VENT, MANUAL
AIR VENT, AUTOMATIC
PRESSURE & TEMPERATURE TAP
A.
HUMIDISTAT
TEMPERATURE SENSOR
DUCT SMOKE DETECTOR
DOOR TRANSFER GRILLE
CARBON DIOXIDE SENSOR
CARBON MONOXIDE SENSOR
NOx (NO+NO2) SENSOR
OCCUPANCY SENSOR WALL MOUNT
OCCUPANCY SENSOR CEILING MOUNT
POINT OF CONNECTION (EXISTING AND NEW WORK)
KEYNOTE TAG
1. KEYNOTE NUMBER 1, 2, 3...
2. DEMOLITION KEYNOTE LETTER A, B, C...
MECHANICAL EQUIPMENT TAG
1. MECHANICAL EQUIPMENT TYPE
2. EQUIPMENT NUMBER
DETAIL TAG
1. DETAIL NUMBER
2. SHEET NUMBER
SECTION TAG
1. SECTION NUMBER
2. SHEET NUMBER
AIR DEVICE TAG
1. DEVICE TYPE (REFER TO AIR
TERMINAL SCHEDULE FOR SIZE)
2. AIRFLOW CFM-TYPE
EMERGENCY SHUTOFF BUTTON
BACK DRAFT DAMPER
FIRE DAMPER
MOTORIZED DAMPER
COMBINATION FIRE/SMOKE DAMPER
DUCT TRANSITION, ROUND OR FLAT OVAL
TO RECTANGULAR
DUCT TRANSITION, RECTANGULAR TO
ROUND OR FLAT OVAL
DUCT TRANSITION, RECTANGULAR,
ROUND, OR FLAT OVAL
INCLINED RISE W/RESPECT TO AIR FLOW,
RECTANGULAR
INCLINED DROP W/RESPECT TO AIR FLOW,
RECTANGULAR
INCLINED RISE W/RESPECT TO AIR FLOW,
ROUND OR FLAT OVAL
INCLINED DROP W/RESPECT TO AIR FLOW,
ROUND OR FLAT OVAL
90° ELBOW, ROUND OR FLAT OVAL
(SMOOTH OR 5 PIECE ELBOWS)
MITERED 90° ELBOW, ROUND OR FLAT
OVAL
RECTANGULAR DUCT WITH 1" INTERNAL
LINER. DUCT SIZE IS THE CLEAR INSIDE
DIMENSION
45° ELBOW, ROUND OR FLAT OVAL
(SMOOTH OR 3 PIECE ELBOWS)
DIVIDED FLOW FITTING
TAP-IN BRANCH, RECTANGULAR
BRANCH DUCT, CONICAL LATERAL FITTING,
ROUND OR FLAT OVAL
BRANCH DUCT, CONICAL TEE FITTING,
ROUND OR FLAT OVAL
SUPPLY DUCT SECTION, RECTANGULAR
RETURN DUCT SECTION, RECTANGULAR
EXHAUST DUCT SECTION, RECTANGULAR
90° ELBOW TURNED UP, RECTANGULAR
90° ELBOW TURNED DOWN, RECTANGULAR
90° ELBOW TURNED UP, ROUND; FLAT
OVAL SIMILAR
90° ELBOW TURNED DOWN, ROUND; FLAT
OVAL SIMILAR
DUCT MOUNTED REGISTER OR GRILLE
(RETURN OR EXHAUST)
DUCT MOUNTED REGISTER OR GRILLE
(SUPPLY)
END DUCT MOUNTED REGISTER OR GRILLE
SUPPLY CEILING DIFFUSER WITH FLEXIBLE
DUCT CONNECTION
RETURN CEILING REGISTER WITH
FLEXIBLE DUCT CONNECTION
STATIC PRESSURE SENSOR
RECTANGULAR DUCT (FIRST FIGURE IS
FOR SIDE SHOWN, SECOND FIGURE IS FOR
SIDE NOT SHOWN), & SYSTEM
ABBREVIATION.
SA - SUPPLY AIR
RA - RETURN AIR
EX - EXHAUST AIR
OA - OUTSIDE AIR
ROUND DUCT
SA - SUPPLY AIR
RA - RETURN AIR
EX - EXHAUST AIR
OA - OUTSIDE AIR
FLEXIBLE ROUND DUCT
DUCT MOUNTED CO2 SENSOR
VOLUME DAMPER
ABBREVIATIONS PIPING SYMBOLS PIPING SYMBOLS (CONT.)
GEN. MECHANICAL SYMBOLS
DOUBLE LINE DUCTWORK
DOUBLE LINE DUCTWORK
S
P
T
DN
CA
H
T
S
CO2
CO
NOx
OS
OS
1 2
ESB
BDD
FD
MD
F/S
DN
DN
UP
UP
16x14 (L)
VD
VD
VD
VD
SPS
16x14 SA
10ø SA
CO2
VD
SHEET ID STRUCTURE
M - 0 0 0
SYSTEM
LEVEL
SHEET
SYSTEMS:
0 - GENERAL
1 - VENTILATION
2 - PIPING
3 - SECTIONS
4 - ENLARGED PLANS
5 - DETAILS
6 - SCHEDULES
7 - HYDRONIC DIAGRAMS
LEVELS:
0 - FIRST FLOOR
90° ELBOW, RECTANGULAR WITH TURNING
VANES
45° ELBOW, RECTANGULAR WITH TURNING
VANES
T
VAV-##
THERMOSTAT SYMBOL
SPECIFIED EQUIPMENT TYPE AND TAG NUMBER
CONTROL WIRING
LENGTH
DUST COLLECTOR
BLAST MACHINE
AIR COMPRESSOR
STORAGE TANK
AIR FILTER SYSTEM
A
AC
ACC
ACCU
AFF
AFMS
AHU
AI
AO
AP
ARCH
ATM
AUTO
AUX
AWT
B B/W
BC
BDD
BFP
BHP
BOD
BOP
BTU
BTUH
C
CA
CAP
CB
CC
CFM
CH
CHWR
CHWS
CI
CL
CO
COL
COMP
COND
CONN
CONT
CP
CR
CS
CT
CTG
Cv
CV
CW
CWP
CWR
CWS
D
DB
DD
DDC
DI
DIA
DISC
DIV
DN
DO
DP
DPT
DS
DTG
DWG
DX
E E(E)
EA
EAT
EF
EFF
ENT
E-P
EQUIP
ESP
ET
EUH
EVAP
EWC
EWT
EXH
EXP
F
FA
FAG
FAP
FCO
FCU
FD
FDC
FE
FEC
FH
FHC
FHR
FHYR
FIXT
FLA
FOR
FOS
FPM
FPS
FS
FST
FT
FTR
G
GALV
GC
GPH
GPM
GPS
H
HB
HC
HD
HEV
HG
HP
HR
HT
HTG
HTR
HWH
HVAC
HWHP
HWHR
HWHS
HYD
HZ
I
ID
IE
IN
INCR
K
KW
L
L
LAT
LAV
LBS
LF
LH
LHG
LIN
LIQ
LL
LMTD
LPS
LTD
LVG
LVR
LWT
M M
MA
MAT
MAX
MBH
MCC
MD
MET
MIN
MP
MPC
MPS
MTD
MU
MVD
MWP
N N/A
NC
NG
NIC
NK
NO
O
OA
OBD
OD
OS&Y
OV
OW
P
PBD
PCF
PC
PCF
PD
P-E
PH
PHC
PI
PKG
PNEU
PNL
PPM
PRESS
PRV
PSI
PSIG
PSV
P'WIRED
Q
QT
QTY
R
RA
RAD
RD
RECIRC
REFRIG
REG
RET
RH
RHC
RL
RPBP
RPM
RPS
RR
RS
RTD
S S/M
SA
SAT
SCFM
SD
SF
SH
SHG
SHT
SP
SPGR
SPKLR
SPT
SPVOL
SS
STD
SYS
T T
TAB
TAU
TCC
TCP
TD
TI
TR
TSP
TT
TYP
U U
UB
UD
UH
UNO
UR
V V
VAC
VAV
VD
VEL
VLV
VPT
VTR
W W W/ W/O
WB
WC
WH
WTR
L
DC
BM
ACP
ST
AFS
1 - ROOF
H - P - I -
DUCTWORK
PIPING
CONTROLS
8 - CONTROLS
PROPYLENE GLYCOLP.G.
SOLDERING EXHAUST FANSEF
LASER EXHAUST FANLEF
VEHICLE EXHAUST FANVEF
ISOLATION VALVE-MOTORIZED
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
N
M
IC
H
IG
A
N A
V E
S U
IT
E
C H
IC
A
G O
IL
p ro j.
n
E N
A M
E
P N
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
B
C
D
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
2 3 4 5
M-001
M E
C H
A N
IC
A
L
F O
R T
B R
A G
G N
C W
IL
M
IN
G
T O
N D
IS
T
R
IC
T D
A R
L
IN
G T
O N
A V
E W
IL
M
IN
G
T O
N N
C
J R
U T
L E
D G
E
A R
U S
S
IN
K S
H E
R L O
C K
J R
U T
L E
D G
E
A U
G
W P
M R
R E
A D
Y T
O A
D V
E R
T
IS
E
S O
F T
E C
H N
IC
A
L S
U P
P O
R T
T R
A
IN
IN
G
A N
N E
X
S Y
M B
O L S
A
B B
R E
V
IA
T
IO
N S
C H
I- -A
M
W P
M F
.r v t
F Y
P
N
.2
F Y
P
N
.2
MECHANICAL LEGEND AND GENERAL NOTES1
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
N
M
IC
H
IG
A
N A
V E
S U
IT
E
C H
IC
A
G O
IL
p ro j.
n
E N
A M
E
P N
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
B
C
D
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
2 3 4 5
M-002
M E
C H
A N
IC
A
L
F O
R T
B R
A G
G N
C W
IL
M
IN
G
T O
N D
IS
T
R
IC
T D
A R
L
IN
G T
O N
A V
E W
IL
M
IN
G
T O
N N
C
J R
U T
L E
D G
E
A R
U S
S
IN
K S
H E
R L O
C K
J R
U T
L E
D G
E
A U
G
W P
M R
R E
A D
Y T
O A
D V
E R
T
IS
E
S O
F T
E C
H N
IC
A
L S
U P
P O
R T
T R
A
IN
IN
G
A N
N E
X
G E
N E
R A
L N
O T
E S
D
E S
IG
N
C R
IT
E
R
IA
C H
I- -A
M
W P
M F
.r v t
F Y
P
N
.2
F Y
P
N
.2
DUCT INSULATION SCHEDULE
DUCT SYSTEM FUNCTION SHAPE LOCATION
MINIMUM
THICKNESS
MINIMUM
R-VALUE
SUGGESTED INSULATION TYPE JACKET NOTES
AHU-1 SUPPLY AIR ALL ABOVE CEILING 1" R-6 CELLULAR GLASS / FLEXIBLE ELASTOMERIC CLOSED CELL FOIL FACE JACKET -
AHU-1 RETURN AIR ALL ABOVE CEILING 1" R-6 CELLULAR GLASS / FLEXIBLE ELASTOMERIC CLOSED CELL FOIL FACE JACKET -
ERV-1 OUTSIDE AIR ALL ANY 2" R-8 CELLULAR GLASS / FLEXIBLE ELASTOMERIC CLOSED CELL FOIL FACE JACKET -
ERV-1 EXHAUST AIR ALL ANY 1" R-6 CELLULAR GLASS / FLEXIBLE ELASTOMERIC CLOSED CELL FOIL FACE JACKET -
ERV-1 RETURN AIR ALL ABOVE CEILING 1" R-6 CELLULAR GLASS / FLEXIBLE ELASTOMERIC CLOSED CELL FOIL FACE JACKET -
ERV-1 FRESH AIR ALL ANY 1" R-6 CELLULAR GLASS / FLEXIBLE ELASTOMERIC CLOSED CELL FOIL FACE JACKET -
DOAS-1 SUPPLY AIR ALL ABOVE CEILING 1" R-6 CELLULAR GLASS / FLEXIBLE ELASTOMERIC CLOSED CELL FOIL FACE JACKET -
DOAS-1 & 2 OUTSIDE AIR ALL ANY 2" R-8 CELLULAR GLASS / FLEXIBLE ELASTOMERIC CLOSED CELL FOIL FACE JACKET -
DOAS-3 SUPPLY AIR ALL EXPOSED - - - - 1
DOAS-3 EXHAUST AIR ALL EXPOSED - - - - 1
DOAS-4 SUPPLY AIR ALL EXPOSED - - - - 1
BCU-1 THRU 4 SUPPLY AIR ALL ABOVE CEILING 1" R-6 CELLULAR GLASS / FLEXIBLE ELASTOMERIC CLOSED CELL FOIL FACE JACKET -
BCU-1 THRU 4 RETURN AIR ALL ABOVE CEILING 1" R-6 CELLULAR GLASS / FLEXIBLE ELASTOMERIC CLOSED CELL FOIL FACE JACKET -
VAV'S SUPPLY AIR ALL ABOVE CEILING 1" R-6 CELLULAR GLASS / FLEXIBLE ELASTOMERIC CLOSED CELL FOIL FACE JACKET -
GENERAL EXHAUST EXHAUST ALL ANY - - - - -
PIPE INSULATION SCHEDULE
PIPE SYSTEM LOCATION
TEMPERATURE
RANGE (°F)
MINIMUM THICKNESS FOR
NOMINAL PIPE SIZE (IN) CONDUCTIVITY
(Btu·in/h·ft²·°F)
SUGGESTED INSULATION TYPE JACKET
VAPOR
BARRIER
(Y/N)< 1"
1 1/4" TO
1 1/2"
2" TO
4"
5" TO
8"
HEATING HOT WATER MECHANICAL ROOMS (AND OTHER HIGH TRAFFIC AREAS) 90 TO 140 1" 1" 1 1/2" 1 1/2" 0.22 TO 0.28 CELLULAR GLASS / FLEXIBLE ELASTOMERIC CELLULAR PVC JACKET N
HEATING HOT WATER ABOVE GRADE (NOT IN MECHANICAL ROOMS) 90 TO 140 1" 1" 1 1/2" 1 1/2" 0.22 TO 0.28 CELLULAR GLASS / FLEXIBLE ELASTOMERIC CELLULAR ALL SERVICE JACKET N
CHILLED WATER MECHANICAL ROOMS (AND OTHER HIGH TRAFFIC AREAS) 40 TO 60 1/2" 1/2" 1" 1" 0.21 TO 0.27 CELLULAR GLASS / FLEXIBLE ELASTOMERIC CELLULAR PVC JACKET Y
CHILLED WATER ABOVE GRADE (NOT IN MECHANICAL ROOMS) 40 TO 60 1/2" 1/2" 1" 1" 0.21 TO 0.27 CELLULAR GLASS / FLEXIBLE ELASTOMERIC CELLULAR ALL SERVICE JACKET Y
CHILLED WATER BELOW GRADE 40 TO 60 1/2" 1/2" 1" 1" 0.21 TO 0.27 CELLULAR GLASS ALUMINUM EMBOSSED JACKET Y
REFRIGERANT SUCTION ABOVE GRADE (NOT IN MECHANICAL ROOMS) - 1/2" 1/2" - - 0.21 TO 0.27 FLEXIBLE ELASTOMERIC CELLULAR ALL SERVICE JACKET N
REFRIGERANT SUCTION EXTERIOR - 1/2" 1/2" - - 0.21 TO 0.27 FLEXIBLE ELASTOMERIC CELLULAR ALUMINUM EMBOSSED JACKET N
REFRIGERANT LIQUID ALL - - - - - - - - -
CONDENSATE MECHANICAL ROOMS 40 TO 60 - - - - - - - -
CONDENSATE ABOVE GRADE (NOT IN MECHANICAL ROOMS) 40 TO 60 1/2" 1/2" 1/2" 1/2" 0.21 TO 0.27 CELLULAR GLASS / FLEXIBLE ELASTOMERIC CELLULAR - N
1. ALL SUPPLY DUCTWORK UPSTREAM OF VAV BOXES SHALL MEET A MINIMUM
DUCT DESIGN STATIC PRESSURE CLASSIFICATION OF 6" PER THE LATEST
SMACNA DUCT CONSTRUCTION STANDARDS.
2. ALL SUPPLY DUCTWORK DOWNSTREAM OF VAV BOXES SHALL MEET A
MINIMUM DUCT DESIGN STATIC PRESSURE CLASSIFICATION OF 2" PER THE
LATEST SMACNA DUCT CONSTRUCTION STANDARDS.
3. ALL OUTDOOR AIR, RETURN AND EXHAUST DUCT SYSTEMS SHALL MEET A
DUCT DESIGN STATIC PRESSURE CLASSIFICATION OF 2" PER THE LATEST
SMACNA DUCT CONSTRUCTION STANDARDS.
4. ALL DUCTWORK SEALING SHALL MEET SEAL LEVEL "A" PER ASHRAE 189.1
(2009) AND THE LATEST SMACNA DUCT CONSTRUCTION STANDARDS.
5. FLEXIBLE DUCT LENGTHS SHALL BE LIMITED TO 5 FT MAXIMUM, AND
INSTALLED PER DETAIL 8/MH502 AND 3/MH503.
6. PROVIDE DUCT FIRE DAMPERS AT ALL RATED WALL PENETRATIONS.
7. PROVIDE MANUAL VOLUME DUCT DAMPERS WHERE SHOWN ON DRAWINGS
AND ALSO IN ALL MAIN BRANCH AND SUB-BRANCH TAKE-OFFS. PROVIDE
MANUAL VOLUME DAMPERS AT ALL DUCT BRANCH TAKE-OFFS TO ALL AIR
TERMINAL DEVICES. PROVIDE AND LOCATE DAMPERS AS INDICATED,
SHOWN, AND PER THE INSTALLATIONS DETAIL 3/MH503. ADEQUATELY SIZED
ACCESS PANELS SHALL BE PROVIDED WHERE DAMPERS ARE LOCATED
ABOVE INACCESSIBLE CEILINGS (I.E. GYP-BOARD, ETC.). MANUAL VOLUME
DAMPERS ARE NOT REQUIRED TO BE INSTALLED IN THE SUPPLY DUCTWORK
UPSTREAM OF VAV BOXES.
8. ALL FLOOR-MOUNTED EQUIPMENT IN MECHANICAL ROOMS SHALL BE
MOUNTED ON 4" HIGH HOUSEKEEPING PADS UNLESS INDICATED OTHERWISE.
PADS SHALL EXTENT A MINIMUM OF 6" BEYOND THE FOOTPRINT OF THE
EQUIPMENT IN ALL DIRECTIONS.
9. ALL EXPOSED EXTERIOR-MOUNTED EQUIPMENT AND METALS SHALL BE
COLOR-KEYED WITH A FACTORY FINISH TO MATCH THE ROOF.
10. FLEXIBLE CONNECTIONS SHALL BE INSTALLED ON ALL DUCT CONNECTIONS
TO AIR HANDLING UNITS.
11. DUCT CONNECTIONS TO DIFFUSERS, REGISTERS, AND GRILLES SHALL BE
SAME AS THE DEVICE NECK SIZE.
12. ALL PIPING AND EQUIPMENT SHALL BE INSTALLED SO THAT MAINTENANCE
OR REMOVAL CAN BE ACCOMPLISHED WITHOUT THE REMOVAL ON ANY
OTHER PIPING AND/OR EQUIPMENT.
13. PROVIDE SLEEVES AND PREPARED OPENINGS FOR DUCTS, PIPING, AND
OTHER PENETRATING ITEMS AS REQUIRED AND PER SPECIFICATIONS.
14. TO AVOID LARGE QUANTITY OF INDIVIDUAL ROOF PENETRATIONS, FOR ALL
PIPING AND CONDUIT ASSOCIATED WITH ROOFTOP AC UNITS SHALL BE
ACCOMPLISH USING PRE-MANUFACTURED ROOF PENETRATION HOUSING
UNITS (I.E. PIPE CHASE HOUSING UNITS). UNITS SHALL BE INSTALLED PER
MANUFACTURERS INSTALLATION INSTRUCTIONS. ROOF CURB SHALL BE
PROVIDED BY THE EQUIPMENT MANUFACTURER OR FIELD-FABRICATED BY
THE CONTRACTOR AND IN ACCORDANCE WITH THE EQUIPMENT
MANUFACTURER INSTALLATION INSTRUCTIONS. SEE SPECIFICATION
SECTIONS 23 81 00.00 20 UNITARY AIR CONDITIONING EQUIPMENT, AND 23 82
02.00 10 UNITARY HEATING AND COOLING EQUIPMENT.
15. BALL VALVES SHALL HAVE EXTENDED OPERATORS THAT STAND-OFF BEYOND
THE PIPE INSULATION THICKNESS.
16. THE INTERIOR OF RA DUCT IN CONFERENCE AND CLASSROOMS SHALL BE
PAINTED WITH "FLAT" BLACK LATEX PAINT TO REDUCE LIGHT BLEED FROM
CEILING SPACE.
17. GRAVITY DAMPERS ARE NOT ALLOWED TO BE USED IN OR AT WALL
OPENINGS/LOUVERS (I.E. WALL-MTD FANS, INTAKES, EXHAUSTS, ETC.).
MOTORIZED DAMPERS SHALL BE USED. MAXIMUM DAMPER LEAKAGE SHALL
BE 3 CFM/FT2 OF DAMPER AREA AT 1.0 INCH W.G.
18. AIRFLOW MEASURING STATIONS (AFMA) SHALL BE SELECTED AND INSTALLED
TO MEET THE MANUFACTURERS STRAIGHT-DUCT LENGTHS REQUIREMENTS
TO INSURE ACCURATE MEASURING, AND SHALL BE COMPATIBLE WITH THE
AVAILABLE DUCT STRAIGHT--LENGTHS THAT THE SYSTEM LAYOUT PROVIDES.
WHERE DUCT LAYOUT RESTRICTS AVAILABLE DUCT LENGTH REQUIREMENTS,
RELOCATION ADJUSTMENTS SHALL BE PERFORMED TO MEET
MANUFACTURERS RECOMMENDATIONS FOR MAXIMUM PERFORMANCE AND
ACCURACY. AIRFLOW VANES SHALL BE INSTALLED IN ALL DIRECTIONAL DUCT
FITTINGS IN DUCT SECTIONS SERVING AFMA'S. SEE SPECS.
19. ALL FAN AND PUMP MOTORS USED IN VARIABLE FLOW SYSTEMS SHALL BE
SUITABLE AND DESIGNED FOR VARIABLE SPEED APPLICATIONS.
20. TRANSFER DUCT OPENINGS SHALL BE PROVIDED IN ALL WALLS THAT EXTENT
TO THE UNDERSIDE OF THE ABOVE STRUCTURE (I.E. FLOOR, ROOF) FOR
PLENUM RA FLOW.
21. PROVIDE SLEEVES AND PREPARED OPENINGS IN WALLS FOR DUCTS, PIPING
AND ALL OTHER PENETRATING ITEMS. PROVIDE STRUCTURAL STEEL
SLEEVES IN LOAD BEARING WALLS.
22. COORDINATE AND ROUTE ALL PIPING AT AIR HANDLING EQUIPMENT SUCH
THAT CLEAR UNRESTRICTED ACCESS IS PROVIDED.
23. COORDINATE AIR HANDLING EQUIPMENT LOCATION WITH CATWALK LAYOUT
(SEE STRUCTURAL) TO PROVIDE UNRESTRICTED ACCESS TO ALL
COMPONENTS.
24. ALL PENETRATIONS INTO STC-RATED AREAS (SEE ARCHITECTURAL DWGS
FOR LOCATIONS) SHALL BE ACOUSTICALLY-SEALED ON BOTH SIDES FOR
SOUND CONTROL.
25. GALVANIZED RIGID SPIRAL DUCTWORK SHALL BE USED FOR SOLDERING
EXHAUST AIR DISTRIBUTION SYSTEM FOR THE EXTRACTION ARM ASSEMBLY.
26. GALVANIZED RIGID SPIRAL DUCTWORK SHALL BE USED FOR VEHICLE
EXHAUST AIR DISTRIBUTION SYSTEM.
27. GALVANIZED SPIRAL DUCTWORK SHALL BE USED FOR EXHAUST FUME HOOD
AIR DISTRIBUTION SYSTEM.
28. EXHAUST CANOPY HOODS (MH-1 THRU MH-12) SHALL COMPLY WITH NFPA 45.
29. CONTRACTOR SHALL PROVIDE ALL REQUIRED STRUCTURAL PLATFORMS AND
FRAMING ASSEMBLIES TO SUPPORT SUSPENDED, WALL-MOUNTED, ABOVE-
FLOOR MOUNTED, AND TRUSS-SUPPORTED AIR HANDLING UNITS AND
EXHAUST FANS SYSTEMS EQUIPMENT.
30. CONTRACTOR SHALL PROVIDE ALL REQUIRED STRUCTURAL PLATFORMS AND
FRAMING ASSEMBLIES TO SUPPORT ABOVE-FLOOR MOUNTED HOSE REELS
ASSEMBLIES, AND SIMILAR ITEMS.
31. PROVIDE BUILDING HVAC EMERGENCY SHUT OFF BUTTON WHERE FIRE
PROTECTION LOCAL OPERATING CONSOLE(S) ARE LOCATED. REFER TO
FA101 & FA102 AND MH105 FOR MORE INFORMATION.
GENERAL NOTES (APPLICABLE TO ALL HVAC SHEETS)
NOTES:
1. COORDINATE WITH ARCHITECTURAL FOR EXPOSED DUCT PAINTING REQUIREMENTS.
DUCT CONSTRUCTION AND DUCT LEAKAGE SCHEDULE
SYSTEM FUNCTION
DUCT PRESSURE CLASS (IN OF W.C.) SUPPLY RETURN / EXHAUST / OUTSIDE AIR
DUCT TEST
PRESSURE
(IN OF W.C.)
NOTESSUPPLY
DUCT
RETURN
DUCT
EXHAUST
DUCT
OUTSIDE
AIR DUCT
ROUND / OVAL RECTANGULAR ROUND / OVAL RECTANGULAR
DUCT SEAL
CLASS
DUCT LEAK
CLASS
DUCT SEAL
CLASS
DUCT LEAK
CLASS
DUCT SEAL
CLASS
DUCT LEAK
CLASS
DUCT SEAL
CLASS
DUCT LEAK
CLASS
DOAS UNIT / ERV SUPPLY +4.0 - - - A 12 A 24 - - - - 4.0 1, 2
DOAS UNIT / ERV RETURN - -2.0 - - - - - - A 12 A 24 2.0 1, 2
DOAS UNIT / ERV OUTSIDE - - - -2.0 A 12 A 24 - - - - 2.0 1, 2
DOAS UNIT / ERV EXHAUST - - -1.0 - - - - - A 12 A 24 2.0 1, 2
AHU SUPPLY +4.0 - - - A 12 A 24 - - - - 4.0 1, 2
AHU RETURN - -2.0 - - - - - - A 12 A 24 2.0 1, 2
VAV TERMINAL UNITS SUPPLY +1.0 - - - A 12 A 24 - - - - 1.0 1, 2
BCU TERMINAL UNITS SUPPLY +1.0 - - - A 12 A 24 - - - - 1.0 1, 2
BCU TERMINAL UNITS RETURN - -1.0 - - - - - - A 12 A 24 1.0 1, 2
GENERAL EXHAUST DUCT EXHAUST - - -1.0 - - - - - A 12 A 24 - 2, 3
NOTES:
1. TEST IN ACCORDANCE WITH UFGS 23 05 93, TESTING, ADJUSTING, AND BALANCING FOR HVAC AND THE PROCEDURES IN SMACNA HVAC AIR DUCT LEAKAGE TEST MANUAL.
2. DUCT SEAL CLASS A IS REQUIRED ON ALL DUCT SYSTEMS.
3. NO TEST REQUIRED.
5" CHWS/R TRENCHED
UNDER GROUND TO
A130 MECHANICAL
ROOM
ACCU
TECHNICAL SUPPORT
TRAINING ANNEX
HAZARDOUS WASTE
STORAGE
DOAS
DOAS
VS
VS
EX
HP
HP
HP
HP
HP
HP
HP
EF
CHILLER
CLEARANCE
TYP.
SCALE: 3/64"=1'-0"
32 16 0 32
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
N
M
IC
H
IG
A
N A
V E
S U
IT
E
C H
IC
A
G O
IL
p ro j.
n
E N
A M
E
PLAN NORTH
P N
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
B
C
D
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
C B
A
KEYPLAN
NTS
2 3 4 5
MH100
M E
C H
A N
IC
A
L
F O
R T
B R
A G
G N
C W
IL
M
IN
G
T O
N D
IS
T
R
IC
T D
A R
L
IN
G T
O N
A V
E W
IL
M
IN
G
T O
N N
C
J R
U T
L E
D G
E
A R
U S
S
IN
K S
H E
R L O
C K
J R
U T
L E
D G
E
A U
G
W P
M R
R E
A D
Y T
O A
D V
E R
T
IS
E
S O
F T
E C
H N
IC
A
L S
U P
P O
R T
T R
A
IN
IN
G
A N
N E
X
S
IT
E P
L A
N
C H
I- -A
M
W P
M F
.r v t
F Y
P
N
.2
F Y
P
N
.2
MECHANICAL SITE PLAN1
1. ALL SUPPLY DUCTWORK UPSTREAM OF VAV BOXES SHALL MEET A MINIMUM
DUCT DESIGN STATIC PRESSURE CLASSIFICATION OF 6" PER THE LATEST
SMACNA DUCT CONSTRUCTION STANDARDS.
2. ALL SUPPLY DUCTWORK DOWNSTREAM OF VAV BOXES SHALL MEET A
MINIMUM DUCT DESIGN STATIC PRESSURE CLASSIFICATION OF 2" PER THE
LATEST SMACNA DUCT CONSTRUCTION STANDARDS.
3. ALL OUTDOOR AIR, RETURN AND EXHAUST DUCT SYSTEMS SHALL MEET A
DUCT DESIGN STATIC PRESSURE CLASSIFICATION OF 2" PER THE LATEST
SMACNA DUCT CONSTRUCTION STANDARDS.
4. ALL DUCTWORK SEALING SHALL MEET SEAL LEVEL "A" PER ASHRAE 189.1
(2009) AND THE LATEST SMACNA DUCT CONSTRUCTION STANDARDS.
5. FLEXIBLE DUCT LENGTHS SHALL BE LIMITED TO 5 FT MAXIMUM, AND
INSTALLED PER DETAIL 8/MH502 AND 3/MH503.
6. PROVIDE DUCT FIRE DAMPERS AT ALL RATED WALL PENETRATIONS.
7. PROVIDE MANUAL VOLUME DUCT DAMPERS WHERE SHOWN ON DRAWINGS
AND ALSO IN ALL MAIN BRANCH AND SUB-BRANCH TAKE-OFFS. PROVIDE
MANUAL VOLUME DAMPERS AT ALL DUCT BRANCH TAKE-OFFS TO ALL AIR
TERMINAL DEVICES. PROVIDE AND LOCATE DAMPERS AS INDICATED, SHOWN,
AND PER THE INSTALLATIONS DETAIL 3/MH503. ADEQUATELY SIZED ACCESS
PANELS SHALL BE PROVIDED WHERE DAMPERS ARE LOCATED ABOVE
INACCESSIBLE CEILINGS (I.E. GYP-BOARD, ETC.). MANUAL VOLUME DAMPERS
ARE NOT REQUIRED TO BE INSTALLED IN THE SUPPLY DUCTWORK UPSTREAM
OF VAV BOXES.
8. ALL FLOOR-MOUNTED EQUIPMENT IN MECHANICAL ROOMS SHALL BE
MOUNTED ON 4" HIGH HOUSEKEEPING PADS UNLESS INDICATED OTHERWISE.
PADS SHALL EXTENT A MINIMUM OF 6" BEYOND THE FOOTPRINT OF THE
EQUIPMENT IN ALL DIRECTIONS.
9. ALL EXPOSED EXTERIOR-MOUNTED EQUIPMENT AND METALS SHALL BE
COLOR-KEYED WITH A FACTORY FINISH TO MATCH THE ROOF.
10. FLEXIBLE CONNECTIONS SHALL BE INSTALLED ON ALL DUCT CONNECTIONS TO
AIR HANDLING UNITS.
11. DUCT CONNECTIONS TO DIFFUSERS, REGISTERS, AND GRILLES SHALL BE
SAME AS THE DEVICE NECK SIZE.
12. ALL PIPING AND EQUIPMENT SHALL BE INSTALLED SO THAT MAINTENANCE OR
REMOVAL CAN BE ACCOMPLISHED WITHOUT THE REMOVAL ON ANY OTHER
PIPING AND/OR EQUIPMENT.
13. PROVIDE SLEEVES AND PREPARED OPENINGS FOR DUCTS, PIPING, AND
OTHER PENETRATING ITEMS AS REQUIRED AND PER SPECIFICATIONS.
14. TO AVOID LARGE QUANTITY OF INDIVIDUAL ROOF PENETRATIONS, FOR ALL
PIPING AND CONDUIT ASSOCIATED WITH ROOFTOP AC UNITS SHALL BE
ACCOMPLISH USING PRE-MANUFACTURED ROOF PENETRATION HOUSING
UNITS (I.E. PIPE CHASE HOUSING UNITS). UNITS SHALL BE INSTALLED PER
MANUFACTURERS INSTALLATION INSTRUCTIONS. ROOF CURB SHALL BE
PROVIDED BY THE EQUIPMENT MANUFACTURER OR FIELD-FABRICATED BY
THE CONTRACTOR AND IN ACCORDANCE WITH THE EQUIPMENT
MANUFACTURER INSTALLATION INSTRUCTIONS. SEE SPECIFICATION
SECTIONS 23 81 00.00 20 UNITARY AIR CONDITIONING EQUIPMENT, AND 23 82
02.00 10 UNITARY HEATING AND COOLING EQUIPMENT.
15. BALL VALVES SHALL HAVE EXTENDED OPERATORS THAT STAND-OFF BEYOND
THE PIPE INSULATION THICKNESS.
16. THE INTERIOR OF RA DUCT IN CONFERENCE AND CLASSROOMS SHALL BE
PAINTED WITH "FLAT" BLACK LATEX PAINT TO REDUCE LIGHT BLEED FROM
CEILING SPACE.
17. GRAVITY DAMPERS ARE NOT ALLOWED TO BE USED IN OR AT WALL
OPENINGS/LOUVERS (I.E. WALL-MTD FANS, INTAKES, EXHAUSTS, ETC.).
MOTORIZED DAMPERS SHALL BE USED. MAXIMUM DAMPER LEAKAGE SHALL
BE 3 CFM/FT2 OF DAMPER AREA AT 1.0 INCH W.G.
18. AIRFLOW MEASURING STATIONS (AFMA) SHALL BE SELECTED AND INSTALLED
TO MEET THE MANUFACTURERS STRAIGHT-DUCT LENGTHS REQUIREMENTS
TO INSURE ACCURATE MEASURING, AND SHALL BE COMPATIBLE WITH THE
AVAILABLE DUCT STRAIGHT--LENGTHS THAT THE SYSTEM LAYOUT PROVIDES.
WHERE DUCT LAYOUT RESTRICTS AVAILABLE DUCT LENGTH REQUIREMENTS,
RELOCATION ADJUSTMENTS SHALL BE PERFORMED TO MEET
MANUFACTURERS RECOMMENDATIONS FOR MAXIMUM PERFORMANCE AND
ACCURACY. AIRFLOW VANES SHALL BE INSTALLED IN ALL DIRECTIONAL DUCT
FITTINGS IN DUCT SECTIONS SERVING AFMA'S. SEE SPECS.
19. ALL FAN AND PUMP MOTORS USED IN VARIABLE FLOW SYSTEMS SHALL BE
SUITABLE AND DESIGNED FOR VARIABLE SPEED APPLICATIONS.
20. TRANSFER DUCT OPENINGS SHALL BE PROVIDED IN ALL WALLS THAT EXTENT
TO THE UNDERSIDE OF THE ABOVE STRUCTURE (I.E. FLOOR, ROOF) FOR
PLENUM RA FLOW.
21. PROVIDE SLEEVES AND PREPARED OPENINGS IN WALLS FOR DUCTS, PIPING
AND ALL OTHER PENETRATING ITEMS. PROVIDE STRUCTURAL STEEL
SLEEVES IN LOAD BEARING WALLS.
22. COORDINATE AND ROUTE ALL PIPING AT AIR HANDLING EQUIPMENT SUCH
THAT CLEAR UNRESTRICTED ACCESS IS PROVIDED.
23. COORDINATE AIR HANDLING EQUIPMENT LOCATION WITH CATWALK LAYOUT
(SEE STRUCTURAL) TO PROVIDE UNRESTRICTED ACCESS TO ALL
COMPONENTS.
24. ALL PENETRATIONS INTO STC-RATED AREAS (SEE ARCHITECTURAL DWGS FOR
LOCATIONS) SHALL BE ACOUSTICALLY-SEALED ON BOTH SIDES FOR SOUND
CONTROL.
25. GALVANIZED RIGID SPIRAL DUCTWORK SHALL BE USED FOR SOLDERING
EXHAUST AIR DISTRIBUTION SYSTEM FOR THE EXTRACTION ARM ASSEMBLY.
26. GALVANIZED RIGID SPIRAL DUCTWORK SHALL BE USED FOR VEHICLE
EXHAUST AIR DISTRIBUTION SYSTEM.
27. GALVANIZED SPIRAL DUCTWORK SHALL BE USED FOR EXHAUST FUME HOOD
AIR DISTRIBUTION SYSTEM.
28. EXHAUST CANOPY HOODS (MH-1 THRU MH-12) SHALL COMPLY WITH NFPA 45.
29. CONTRACTOR SHALL PROVIDE ALL REQUIRED STRUCTURAL PLATFORMS AND
FRAMING ASSEMBLIES TO SUPPORT SUSPENDED, WALL-MOUNTED, ABOVE-
FLOOR MOUNTED, AND TRUSS-SUPPORTED AIR HANDLING UNITS AND
EXHAUST FANS SYSTEMS EQUIPMENT.
30. CONTRACTOR SHALL PROVIDE ALL REQUIRED STRUCTURAL PLATFORMS AND
FRAMING ASSEMBLIES TO SUPPORT ABOVE-FLOOR MOUNTED HOSE REELS
ASSEMBLIES, AND SIMILAR ITEMS.
GENERAL NOTES (APPLICABLE TO ALL HVAC SHEETS)
R E
F
RAF
HWP
HWP
CHWP
CHWP
ACH
ACH
ACH
ACH
6 HP
HP
HP
HP
HP
EF
UH
ET
VAV
VAV
VAV
VAV
VAV
ACH
NIPR ROOM
A110
SIPR
A112
VEHICLE
ELECTRONIC
TRAINING BAYS
A113
PSC CLASSROOM
A106
STUDENT
WOMENS
TOILET/SHOWER
A108
STUDENT MENS
TOILET/SHOWER
A109
BREAKROOM
A101
ESS TR
A137
JAN.
A136
STORAGE
A134
RECYC.
A135
CADRE MENS
TOILET
A133
CADRE WOMENS
TOILET
A132
STOR.
A139
PSC/TSC CADRE
OFFICES
A127
CHIEF/NCOIC
OFFICE
A126
TSC/PSC NCOIC
OFFICE
A125
LEAD
CONTRACTOR
OFFICE
A124
CONFERENCE
A121
STOR.
A122
A/V
A123
P H
O T
O S
T O
R
A
PROTOTYPE
ROOM
A118
CNC SHOP
A117
LAB STOR
A119
ELECT. RM 2
A120
TSC STORAGE
A128
PSC STOR.
A129
MECHANICAL
A130
ELECTRICAL
ROOM
A131
VESTIBULE
A100
CORRIDOR
A102
GARAGE
TRAINING
A141
TSC CLASSROOM
A103
VAV
VAV
VAV
VAV
VAV
VAV
8 VAV
VAV
VAV
VAV
VAV
VAV
VAV
VAV
VAV
PBEF
FIRE
PROTECTION
AREA
VAV
ACH
HP
L-1
L-2
STOR.
A138
BCU
BCU
BCU
EF
LEF
LEF
HVAC CONTROL PANELS
WPAC
ET
B
FABRICATION
SHOP
A116
ACH
HP
PB
BCU
BP
AHU
DOAS
GR ON
ROOF
MEF
MEF
MEF
SEF
UH
VHR
VHR
VHR
VHR
VHR
VEF
VEF
VEF
VEF
VEF
UH
RC
DOAS
AHU
DOAS
EQUIP. UP ON CONCRETE
EQUIPMENT PLATFORM
CONCRETE EQUIPMENT PLATFORM
OVER TSC STORAGE A128 & PSC STOR.
A129
SCENARIO ROOM
A115
MOLDING EXHAUST
HOOD MH-1 THRU MH-12.
VAV
VAV
VAV
VS
VS
ERV
EX
L-5
L-4
L-6
L-3
AT EXTERIOR WALL ABOVE,
SEE ELEVATION 1/A-202
ESB
HVAC EMERGENCY
SHUT OFF BUTTON
ESB
HVAC EMERGENCY
SHUT OFF BUTTON
EQUIPMENT SECURITY
FENCING, REFER TO
ARCHITECTURAL & CIVIL
FOR ADDITIONAL DETAILS
EQUIPMENT
SECURITY FENCING,
REFER TO
ARCHITECTURAL &
CIVIL FOR
ADDITIONAL DETAILS
DOAS
EF
PRE-FABRICATED
POL /
HAZARDOUS
WASTE STORAGE
BUILDING
A145
L-7
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
N
M
IC
H
IG
A
N A
V E
S U
IT
E
C H
IC
A
G O
IL
p ro j.
n
E N
A M
E
PLAN NORTH
P N
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
B
C
D
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
C B
A
KEYPLAN
NTS
2 3 4 5
MH101
M E
C H
A N
IC
A
L
F O
R T
B R
A G
G N
C W
IL
M
IN
G
T O
N D
IS
T
R
IC
T D
A R
L
IN
G T
O N
A V
E W
IL
M
IN
G
T O
N N
C
J R
U T
L E
D G
E
A R
U S
S
IN
K S
H E
R L O
C K
J R
U T
L E
D G
E
A U
G
W P
M R
R E
A D
Y T
O A
D V
E R
T
IS
E
S O
F T
E C
H N
IC
A
L S
U P
P O
R T
T R
A
IN
IN
G
A N
N E
X
F
IR
S T
F L O
O R
H V
A C
P L A
N
O V
E R
A L L
C H
I- -A
M
W P
M F
.r v t
F Y
P
N
.2
F Y
P
N
.2
FIRST FLOOR HVAC PLAN - OVERALL1
SCALE: 3/32"=1'-0"
816 16
MATCH
LINE
SEE
MH103
MATCH
LINE
SEE
MH102
MH401
NIPR ROOM
A110
SIPR
A112
PSC CLASSROOM
A106
BREAKROOM
A101
ESS TR
A137
JAN.
A136
STORAGE
A134
RECYC.
A135CADRE MENS
TOILET
A133
CADRE WOMENS
TOILET
A132
STOR.
A139
PSC/TSC CADRE
OFFICES
A127
CHIEF/NCOIC
OFFICE
A126
TSC/PSC NCOIC
OFFICE
A125
LEAD
CONTRACTOR
OFFICE
A124
CONFERENCE
A121
STOR.
A122
A/V
A123
PHOTO STOR.
A114
PROTOTYPE
ROOM
A118
L A
B S
T O
R
A
ELECT. RM 2
A120
MECHANICAL
A130
ELECTRICAL
ROOM
A131
VESTIBULE
A100
CORRIDOR
A102
TSC CLASSROOM
A103
32/28 RA
6ø SA
/1
E
A
12/10 EA
12ø SA
12/12 SA
ø
S A ø
S A ø
S A
10/10 SA
8/10 SA
18/16 RA
10/10 SA
8ø SA
10/8 SA
8ø RA
14ø SA
/1
R
A
8ø SA 8ø SA
8ø SA
16ø SA ø
O A
10ø SA
10ø SA
8ø SA 8ø SA
8ø SA 8ø SA
G 350
G 350 G 350
G 320
K 500
K 700
G 425
K 450
G 225G 225 G 225 F 250
F 200
E 120
E 100
E 120
F 185
G 350
L 1050
J 200
E 50
E 100
E
F
F 175
F 175
E 100 E 100
E 50
P 145
P 150
Q 100
O 75
Q 75
O 50
Q 100
Q 50
Q 150
O 50
D 200
J 200
J 200
J 200
J 200
R 175
J 200
R 150
R 205
MATCH LINE
MATCH LINE
Q 50
R 200
Q 50
J 200
K 700
4ø EA
D 125
10ø SA
/2
R
A
12/12 SA
8/10 SA
6X6 EA WALL CAP
WITH BACKDRAFT
DAMPER
6"Ø EA WALL
CAP
WITH
BACKDRAFT
DAMPER
ø
S A
FABRICATION
SHOP
A116
MH402
MH402
G 350
TYP OF 4
F-1 ø
S A ø
S A
8ø SA
16/10 SA
CNC SHOP
A117
TYP. OF 2
/1
E
A ø
S A
10ø SA 8ø SA
8ø RA
TYP. OF 2 1
ø
S A ø
S A
/1
S
A ø
S A
12/8 EA
/1
S
A
8ø SA
6ø EA
8ø RA
6ø SA
6ø SA
6ø SA
TYP. OF 4
TYP.
OF 4
10ø RA 8ø RA 8ø RA
10ø RA
10/12 SA
10ø SA10ø SA10ø RA
10ø SA ø
S A
10ø SA10ø SA
10ø RA
12ø SA
12ø RA
TYP. OF 2
12/10 EA
12ø RA
TYP. OF 4
6ø SA ø
S A
10/8 SA
TYP. OF 3
22/20 RA
14ø RA 14ø RA
TYP. OF 3
14ø RA
TYP. OF 3
12/12 SA
10ø SA
10ø SA
10ø SA
16/10 SA 16/10 SA
/1
S
A
10ø SA
10ø SA
/1
S
A
14ø RA
34/28 SA
6ø SA
TYP. OF 4
G 350
MH401
16ø RA
26/22 OA
AFMA
34/28 SA 12/16 EA
6/6 OA
L-3
O 75
8/8 EA
ø
S A ø
S A
8ø SA
20/18 RA
/1
S
A24/18 SA
24/18 SA 18/18 SA 14ø SA
16/12 EA
16/12 EA
10ø SA
16/12 SA
10ø SA
G 350
TYP. OF 3
TYP. OF 2
24/18 EA
/1
E
A
12/12 SA
10ø SA
12/12 SA
8ø SA
24/20 SA 22/20 SA
8ø RA
L-4 ø
R A
6ø EA ø
E A
6ø EA
8ø EA 8ø EA
8ø EA
6ø EA
8ø EA
/1
E
A
8ø EA
6ø EA ø
E A ø
E A ø
E A
10/10 EA
12/12 OA
10ø OA
10ø OA
C 50 ø
E A
TYP. OF 2
/2
S
A /2
S
A
/2
R
A
E 50
14ø RA
8/8 SA
MH402
12ø RA
16/16 RA
8ø RA
D-8
10/10 EA
D-7
F 185
EF
HP
HP
HP
HP
A.A.D
ACH
ACH
ACH
ACH
VAV
VAV
VAV
VAV
VAV
VAV
VAV
HP
HP
VAV
12 VAV
VAV
VAV
10VAV
ACH
VAV
VAV
VAV
VAV
VAV
VAV
ACH
HP
BCU
LEF
LEF
ACH
BCU
VAV
VAV
VAV
6ø EA
28/24 OA
16/16 SA
C
8ø OA
6ø OA
8ø SA
6ø SA ø
S A
E 120
GENERAL SHEET NOTES:
LAYOUT IS DIAGRAMMATIC IN NATURE. ALL
WORK SHALL BE COORDINATED WITH OTHER
TRADES.
PRIOR TO WORK THE FOLLOWING SHALL BE
VERIFIED; SITE ACCESS AND RIGGING
ROUTES FOR MECHANICAL EQUIPMENT
INSTALLATIONS.
NEW DUCTWORK, AND ASSOCIATED
INSTALLATIONS SHALL NOT CROSS ABOVE
ELECTRIC PANELS. COORDINATE WITH
EXISTING CONDITIONS IN FIELD.
ALL OUTSIDE AIR AND EXHAUST MOTORIZED
DAMPERS SHALL BE LOW LEAKAGE TYPE TO
COMPLY WITH ATFP REQUIREMENTS.
FLEXIBLE DUCT LENGTH SHALL BE LIMITED TO
5 FT MAXIMUM AND INSTALLED PER DETAIL
3/MH503.
TOILET EXHAUST DUCT WORK MUST HAVE
MINIMUM OF TWO 90 DEGREE ELBOWS
BEFORE TERMINATION AT AIR TERMINAL
DEVICE.
PROVIDE FIRE DAMPERS AT ALL RATED WALL
PENETRATIONS.
PROVIDE MANUAL VOLUME DAMPERS AT ALL
DUCT BRANCH TAKE-OFFS TO AN AIR
TERMINAL. PROVIDE ACCESS PANELS WHERE
DAMPERS ARE LOCATED ABOVE
INACCESSIBLE CEILINGS OR PROVIDE A
CABLE OPERATED DAMPER INSTALLED PER
MANUFACTURER'S RECOMMENDATIONS.
ALL FLOOR MOUNTED MECHANICAL
EQUIPMENT SHALL BE INSTALLED ON 4" HIGH
HOUSEKEEPING PAD UNLESS INDICATED
OTHERWISE. PAD SHALL EXTEND 6" BEYOND
FOOTPRINT OF EQUIPMENT IN ALL
DIRECTIONS.
PROVIDE MANUFACTURER REQUIRED
CLEARANCE FOR ALL MECHANICAL
EQUIPMENT.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
N
M
IC
H
IG
A
N A
V E
S U
IT
E
C H
IC
A
G O
IL
p ro j.
n
E N
A M
E
PLAN NORTH
P N
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
B
C
D
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
C B
A
KEYPLAN
NTS
2 3 4 5
MH102
M E
C H
A N
IC
A
L
F O
R T
B R
A G
G N
C W
IL
M
IN
G
T O
N D
IS
T
R
IC
T D
A R
L
IN
G T
O N
A V
E W
IL
M
IN
G
T O
N N
C
J R
U T
L E
D G
E
A R
U S
S
IN
K S
H E
R L O
C K
J R
U T
L E
D G
E
A U
G
W P
M R
R E
A D
Y T
O A
D V
E R
T
IS
E
S O
F T
E C
H N
IC
A
L S
U P
P O
R T
T R
A
IN
IN
G
A N
N E
X
F
IR
S T
F L O
O R
H V
A C
P L A
N
A R
E A
A
C H
I- -A
M
W P
M F
.r v t
F Y
P
N
.2
F Y
P
N
.2
FIRST FLOOR HVAC FLOOR PLAN - AREA A1
164 8268
SCALE: 1/8"=1'-0"
VEHICLE
ELECTRONIC
TRAINING BAYS
A113
SCENARIO ROOM
A115
GARAGE
TRAINING
A141
J 200
E 75
E 100
E
E 125
L 925
R 225
P 225
MATCH LINE
MATCH LINE
Q 125
F 230
D 175 D 185
10ø SA
6ø SA
14ø SA
12ø SA
TYP. OF 4
20/20 EA
ø
E A
20/20 SA
20/20 SA
20ø SA 16ø SA
TYP. OF 4
4ø EA 4ø EA
4ø EA 4ø EA 4ø EA
STUDENT MENS
TOILET/SHOWER
A109
TSC STORAGE
A128
MH301
MH301
STUDENT
WOMENS
TOILET/SHOWER
A108
B 125
8/6 SA
B 135
10/8 SA
12/10 EA
N 150N 150
12/8 EA
6ø SA 6ø SA 8ø RA
8ø SA ø
E A ø
E A ø
E A ø
E A
8ø SA
TYP. OF 2
8ø SA
10/8 SA 14/12 SA
12/16 EA
ø
S A
TYP. OF 4
14/12 SA
8ø SA
8ø SA
8ø SA
8ø SA
3ø EA 3ø EA
3ø EA
3ø EA
3ø EA
3ø EA
4ø EA 3ø EA 8ø EA
6ø EA
4ø EA ø
E A
3ø EA 3ø EA
TYP. OF 2
18ø EA 14ø EA ø
R A
8ø SA8ø SA
8ø SA 8ø SA
F 250
12/8 EA
1 2
A 550
L 900
TYP. OF 2 O 125
26/22 OA
16/16 SA
14ø RA
8/10 SA
ACCESS
LADDER
D-10
DOAS
RC
UH
UH
VEF
BCU
VEF
VEF
VEF
VEF
VHR
5VHR
VHR
VHR
VHR
VAV
VAV
VAV
SEF
12/10 EA
3' - 6"
VD (TYP.)
EQUIPMENT SECURITY FENCING, REFER TO
ARCHITECTURAL & CIVIL FOR ADDITIONAL DETAILS
CAGE STORAGE CAGE STORAGE
MATCH LINE
MATCH LINE
SCENARIO ROOM
A115
GARAGE
TRAINING
A141
VEHICLE
ELECTRONIC
TRAINING BAYS
A113
STUDENT MENS
TOILET/SHOWER
A109
STUDENT
WOMENS
TOILET/SHOWER
A108
L-6 16/14 OA 14/14 OA
14/14 OA
10ø OA
14/14 OA
10ø OA
10ø OA
G 400
48/24 RA
22ø SA
22/22 SA
16ø SA
I 3000
A 600
TYP. OF 5
MH301
2' - 0"
TYP. OF 3
18ø SA
ACCESS
LADDER
D-9
AHU
DOAS
24/24 OA
VD, (TYP.)
KEY NOTES:
COORDINATE FINAL LOCATION OF DOAS-3 WITH
CIVIL.
ROUTE SUPPLY DUCT ABOVE BOTTOM OF
STRUCTURAL FRAMING.
EXHAUST DUCT DOWN, TYPICAL. REFER TO 2/MH301
FOR MORE DETAILS.
VEF EXHAUST DUCT UP THROUGH ROOF, TYPICAL.
REFER TO 1/MH301
FOR MORE DETAILS.
AHU-2 & DOAS-2 ON CONCRETE EQUIPMENT
PLATFORM ABOVE TSC STORAGE ROOM. REFER TO
3/MH301 FOR MORE DETAILS.
MAINTAIN MINIMUM OF 2' CLEARANCE BETWEEN
RETURN DUCT AND SAFETY RAILING.
MAINTAIN SERVICE CLEARANCE BETWEEN AHU-2 &
DOAS-2 AS RECOMMENDED BY MANUFACTURER.
3" DIA DUCT DOWN TO EXHAUST ARM ASSEMBLY
FOR SOLDERING FUME EXTRACTION SYSTEM
(TYPICAL OF 12 ). SEE 7/MH506 FOR
DETAIL/CONFIGURATION.
INSTALL UNIT ON 4" HOUSEKEEPING PAD. REFER TO
STRUCTURAL.
REFER TO ARCHITECTURAL FOR EXACT SIZE,
LOCATION, AND FEATURES OF CHAIN LINKED FENCE
GENERAL SHEET NOTES:
LAYOUT IS DIAGRAMMATIC IN NATURE. ALL WORK
SHALL BE COORDINATED WITH OTHER TRADES.
PRIOR TO WORK THE FOLLOWING SHALL BE VERIFIED;
SITE ACCESS AND RIGGING ROUTES FOR MECHANICAL
EQUIPMENT INSTALLATIONS.
NEW DUCTWORK, AND ASSOCIATED INSTALLATIONS
SHALL NOT CROSS ABOVE ELECTRIC PANELS.
COORDINATE WITH EXISTING CONDITIONS IN FIELD.
ALL OUTSIDE AIR AND EXHAUST MOTORIZED DAMPERS
SHALL BE LOW LEAKAGE TYPE TO COMPLY WITH ATFP
REQUIREMENTS.
FLEXIBLE DUCT LENGTH SHALL BE LIMITED TO 5 FT
MAXIMUM AND INSTALLED PER DETAIL 3/MH503.
TOILET EXHAUST DUCT WORK MUST HAVE MINIMUM
OF TWO 90 DEGREE ELBOWS BEFORE TERMINATION
AT AIR TERMINAL DEVICE.
PROVIDE FIRE DAMPERS AT ALL RATED WALL
PENETRATIONS.
PROVIDE MANUAL VOLUME DAMPERS AT ALL DUCT
BRANCH TAKE-OFFS TO AN AIR TERMINAL. PROVIDE
ACCESS PANELS WHERE DAMPERS ARE LOCATED
ABOVE INACCESSIBLE CEILINGS OR PROVIDE A CABLE
OPERATED DAMPER INSTALLED PER
MANUFACTURER'S RECOMMENDATIONS.
ALL FLOOR MOUNTED MECHANICAL EQUIPMENT SHALL
BE INSTALLED ON 4" HIGH HOUSEKEEPING PAD
UNLESS INDICATED OTHERWISE. PAD SHALL EXTEND
6" BEYOND FOOTPRINT OF EQUIPMENT IN ALL
DIRECTIONS.
PROVIDE MANUFACTURER REQUIRED CLEARANCE
FOR ALL MECHANICAL EQUIPMENT.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
N
M
IC
H
IG
A
N A
V E
S U
IT
E
C H
IC
A
G O
IL
p ro j.
n
E N
A M
E
PLAN NORTH
P N
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
B
C
D
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
C B
A
KEYPLAN
NTS
2 3 4 5
MH103
M E
C H
A N
IC
A
L
F O
R T
B R
A G
G N
C W
IL
M
IN
G
T O
N D
IS
T
R
IC
T D
A R
L
IN
G T
O N
A V
E W
IL
M
IN
G
T O
N N
C
J R
U T
L E
D G
E
A R
U S
S
IN
K S
H E
R L O
C K
J R
U T
L E
D G
E
A U
G
W P
M R
R E
A D
Y T
O A
D V
E R
T
IS
E
S O
F T
E C
H N
IC
A
L S
U P
P O
R T
T R
A
IN
IN
G
A N
N E
X
F
IR
S T
F L O
O R
H V
A C
P L A
N
A R
E A
B
C H
I- -A
M
W P
M F
.r v t
F Y
P
N
.2
F Y
P
N
.2
FIRST FLOOR HVAC PLAN - AREA B1
164 8268
SCALE: 1/8"=1'-0"
FIRST FLOOR HVAC PLAN - AREA B - CONCRETE EQUIP. PLATFORM2
164 8268
A 590
FD
M H
EF
DOAS
12ø SA
16ø SA
18/18 SA
A 580
A 580
PRE-FABRICATED
POL /
HAZARDOUS
WASTE STORAGE
BUILDING
A145
D-13
L-7
PROVIDE WALL PROPELLER FAN MOTOR SUITABLE
FOR HAZARDOUS CHEMICAL ENVIRONMENT.
VD, TYP.
KEY NOTES:
ROUTE DUCT AS HIGH AS POSSIBLE.
MOUNT FAN AS HIGH AS POSSIBLE.
REFER TO DETAIL 1/MH502 FOR MORE
INFORMATION ON FAN MOUNTING.
INSTALL UNIT ON CONCRETE EQUIPMENT
PAD.
DOAS
18/18 SA
FD
VD
EF
CONCRETE
EQUIPMENT
PAD
A 580
PRE-FABRICATED
POL /
HAZARDOUS
WASTE STORAGE
BUILDING
A145
FLOOR
ROOF
GENERAL SHEET NOTES:
LAYOUT IS DIAGRAMMATIC IN NATURE. ALL WORK
SHALL BE COORDINATED WITH OTHER TRADES.
PRIOR TO WORK THE FOLLOWING SHALL BE VERIFIED;
SITE ACCESS AND RIGGING ROUTES FOR MECHANICAL
EQUIPMENT INSTALLATIONS.
NEW DUCTWORK, AND ASSOCIATED INSTALLATIONS
SHALL NOT CROSS ABOVE ELECTRIC PANELS.
COORDINATE WITH EXISTING CONDITIONS IN FIELD.
ALL OUTSIDE AIR AND EXHAUST MOTORIZED DAMPERS
SHALL BE LOW LEAKAGE TYPE TO COMPLY WITH ATFP
REQUIREMENTS.
FLEXIBLE DUCT LENGTH SHALL BE LIMITED TO 5 FT
MAXIMUM AND INSTALLED PER DETAIL 3/MH503.
TOILET EXHAUST DUCT WORK MUST HAVE MINIMUM
OF TWO 90 DEGREE ELBOWS BEFORE TERMINATION
AT AIR TERMINAL DEVICE.
PROVIDE FIRE DAMPERS AT ALL RATED WALL
PENETRATIONS.
PROVIDE MANUAL VOLUME DAMPERS AT ALL DUCT
BRANCH TAKE-OFFS TO AN AIR TERMINAL. PROVIDE
ACCESS PANELS WHERE DAMPERS ARE LOCATED
ABOVE INACCESSIBLE CEILINGS OR PROVIDE A CABLE
OPERATED DAMPER INSTALLED PER
MANUFACTURER'S RECOMMENDATIONS.
ALL FLOOR MOUNTED MECHANICAL EQUIPMENT SHALL
BE INSTALLED ON 4" HIGH HOUSEKEEPING PAD
UNLESS INDICATED OTHERWISE. PAD SHALL EXTEND
6" BEYOND FOOTPRINT OF EQUIPMENT IN ALL
DIRECTIONS.
PROVIDE MANUFACTURER REQUIRED CLEARANCE
FOR ALL MECHANICAL EQUIPMENT.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
N
M
IC
H
IG
A
N A
V E
S U
IT
E
C H
IC
A
G O
IL
p ro j.
n
E N
A M
E
PLAN NORTH
P N
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
B
C
D
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
C B
A
KEYPLAN
NTS
2 3 4 5
MH104
M E
C H
A N
IC
A
L
F O
R T
B R
A G
G N
C W
IL
M
IN
G
T O
N D
IS
T
R
IC
T D
A R
L
IN
G T
O N
A V
E W
IL
M
IN
G
T O
N N
C
J R
U T
L E
D G
E
A R
U S
S
IN
K S
H E
R L O
C K
J R
U T
L E
D G
E
A U
G
W P
M R
R E
A D
Y T
O A
D V
E R
T
IS
E
S O
F T
E C
H N
IC
A
L S
U P
P O
R T
T R
A
IN
IN
G
A N
N E
X
F
IR
S T
F L O
O R
H V
A C
P L A
N
A R
E A
C
C H
I- -A
M
W P
M F
.r v t
F Y
P
N
.2
F Y
P
N
.2
04 8268 02 4 8134
SCALE: 1/4"=1'-0"
HAZARDOUS WASTE STORAGE SECTION2
04 8268 02 4 8134
SCALE: 1/4"=1'-0"
1 FIRST FLOOR HVAC PLAN - AREA C
N
R E
F
RAF
HWP
HWP
CHWP
CHWP
ACH
ACH
ACH
ACH
HP
HP
HP
HP
HP
EF
UH
ET
VAV
VAV
VAV
VAV
VAV
ACH
NIPR ROOM
A110
SIPR
A112
VEHICLE
ELECTRONIC
TRAINING BAYS
A113
PSC CLASSROOM
A106
BREAKROOM
A101
ESS TR
A137
JAN.
A136
STORAGE
A134
RECYC.
A135
CADRE MENS
TOILET
A133
CADRE WOMENS
TOILET
A132
STOR.
A139
PSC/TSC CADRE
OFFICES
A127
CHIEF/NCOIC
OFFICE
A126
TSC/PSC NCOIC
OFFICE
A125
LEAD
CONTRACTOR
OFFICE
A124
CONFERENCE
A121
STOR.
A122
A/V
A123
PHOTO STOR.
A114
PROTOTYPE
ROOM
A118
CNC SHOP
A117
LAB STOR
A119
ELECT. RM 2
A120
FABRICATION
SHOP
A116
SCENARIO ROOM
A115
TSC STORAGE
A128PSC STOR.
A129
MECHANICAL
A130
ELECTRICAL
ROOM
A131
VESTIBULE
A100
CORRIDOR
A102
GARAGE
TRAINING
A141
TSC CLASSROOM
A103
VAV
VAV
VAV
VAV
VAV
VAV
VAV
VAV
VAV
VAV
VAV
VAV
VAV
VAV
VAV
PBEF
VAV
ACH
HP
STOR.
A138
BCU
BCU
BCU
EF
LEF
LEF
HVAC
CONTROL
PANELS
CO2
S
VEF-3
S
VEF-4
S
VEF-5
S
VEF-1
S
SEF-1
S
PBEF-1
T
T
T
RC
T
RC
T
CO2
DS
DOAS-3
AHU-2
DS
DOAS-3
AHU-2
DS
DOAS-3
AHU-2
DS
DOAS-3
AHU-2
S
VEF-2
WPAC
ACH
T
T
T
EF-2
T
UH-1
NOx
FAFA
T
T T
T
T
T T
T
T
T
T
T
T T
T
T
T
T
T
T
FA
DOAS-3AHU-2
DOAS-2
T
BCU-1
S
EF-3
MEF
MEF
MEF
HP
ET
B
BP
T
UH-2
UH
UH
AHU
DOAS
RC
DOAS
DP
DP
DP
VAV
VAV
VAV
BCU
DOAS
AHU
SEF
VEF
VEF
VEF
VEF
VEF
T
T
UH-3
T
DP (-)
GR ON
ROOF
GFS
ESB
HVAC EMERGENCY
SHUT OFF BUTTON
ESB
HVAC EMERGENCY
SHUT OFF BUTTON
S
MEF-1
S
MEF-2
S
MEF-3
T
S
LEF-1
S
LEF-2
EF
T
EF-1
CO2
CO2
CO2
DOAS
T
EF
PRE-FABRICATED
POL /
HAZARDOUS
WASTE STORAGE
BUILDING
A145
H
KEY NOTES:
1 SWITCH SHALL BE AUTO OFF SPRINGWOUND, TWIST
KNOB WITH A TIME RANGE OF SIX (6) HOURS.
PROVIDE 120V SPST CONTACT. US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
N
M
IC
H
IG
A
N A
V E
S U
IT
E
C H
IC
A
G O
IL
p ro j.
n
E N
A M
E
PLAN NORTH
P N
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
B
C
D
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
C B
A
KEYPLAN
NTS
2 3 4 5
MH105
M E
C H
A N
IC
A
L
F O
R T
B R
A G
G N
C W
IL
M
IN
G
T O
N D
IS
T
R
IC
T D
A R
L
IN
G T
O N
A V
E W
IL
M
IN
G
T O
N N
C
J R
U T
L E
D G
E
A R
U S
S
IN
K S
H E
R L O
C K
J R
U T
L E
D G
E
A U
G
W P
M R
R E
A D
Y T
O A
D V
E R
T
IS
E
S O
F T
E C
H N
IC
A
L S
U P
P O
R T
T R
A
IN
IN
G
A N
N E
X
F
IR
S T
F L O
O R
H V
A C
P L A
N
O V
E R
A L L
T H
E R
M O
S T
A T
S
S E
N S
O R
S
S W
IT
C
H E
S C
H I-
-A
M
W P
M F
.r v t
F Y
P
N
.2
F Y
P
N
.2
FIRST FLOOR HVAC PLAN - AREA A & B1
SCALE: 3/32"=1'-0"
816 16
FIRST FLOOR HVAC PLAN - AREA C2
164 8268
16ø SA
18ø EA 14ø EA
20/6 EA
20/6 EA
VHF
(TYP.)
HEAVY DUTY EA
GRILLES MOUNT 4'-8"
AFF MAXIMUM (TYP)
4" HOSE
(TYP.)
ALL VEHICLE
EXHAUST DUCT
SHALL BE
WELDED SEAM
DUCT (TYP.)
VENT CAP (TYP.)
REFER TO DETAIL
3/MH504
FLOOR
ROUTE S.A. DUCTWORK
ABOVE STRUCTURAL
FRAMING
ROOF
VEF (TYP.)PROVIDE VOLUME
DAMPER AT EACH
EA DUCT RISER
M 550
TYP. OF 4
COORDINATE EA DUCT
WITH WALL MOUNTED
DEVICES AND INSTRUMENTS
ROUTE EX DUCT ABOVE
WINDOW. COORDINATE
WITH ARCH.
45°
135°
4ø EA
6/20 EA
VENT CAP (TYP.)
REFER TO DETAIL
3/MH504
16ø SA
14ø EA
M 550
VHF
(TYP.)
VEF (TYP.)
(TYP. OF 4)
A 550
(TYP. OF 4)
VD, (TYP.)
VD, (TYP.)
BOLLARD, (TYP.)
16ø SA 18ø SA
AHU
I 3000
A 600
24/48 RA
TYP. OF 5
CAGED STORAGE AREA
STORAGE ROOM
EQUIPMENT PLATFORM
M
IN
SAFETY RAILING
SAFETY
RAILING
4" HOUSE
KEEPING PAD
B
CONCRETE
HOUSEKEEPING PAD
6ø OA
6" FLUE UP
THRU
ROOF
PROVIDE AIR INTAKE TERMINATION BASED ON
MANUFACTURERS RECOMMENDATIONS
PROVIDE FLUE
TERMINATION
BASED ON
MANUFACTURERS
RECOMMENDATIONS
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
N
M
IC
H
IG
A
N A
V E
S U
IT
E
C H
IC
A
G O
IL
p ro j.
n
E N
A M
E
P N
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
B
C
D
CONTROLLED UNCLASSIFIED INFORMATION (CUI)
2 3 4 5
MH301
M E
C H
A N
IC
A
L
F O
R T
B R
A G
G N
C W
IL
M
IN
G
T O
N D
IS
T
R
IC
T D
A R
L
IN
G T
O N
A V
E W
IL
M
IN
G
T O
N N
C
J R
U T
L E
D G
E
A R
U S
S
IN
K S
H E
R L O
C K
J R
U T
L E
D G
E
A U
G
W P
M R
R E
A D
Y T
O A
D V
E R
T
IS
E
S O
F T
E C
H N
IC
A
L S
U P
P O
R T
T R
A
IN
IN
G
A N
N E
X
H V
A C
S E
C T
IO
N
S
C H
I- -A
M
W P
M F
.r v t
F Y
P
N
.2
F Y
P
N
.2
04 8268 02 4 8134
SCALE: 1/4"=1'-0"
VEHICLE BAY SECTION - VEF & EXHAUST RETURN1 VEHICLE BAY SUPPLY & EXHAUST DUCTWORK2
04 8268 02 4 8134
SCALE: 1/4"=1'-0"
REFERENCED DRAWINGS: 1/MH301 REFERENCED DRAWINGS: 1/MH301
STORAGE ROOM EQUPMENT PLATFORM3
04 8268 02 4 8134
SCALE: 1/4"=1'-0"
REFERENCED DRAWINGS: 2/MH301 MECHANICAL ROOM BOILER SECTION4
04 8268 02 4 8134
SCALE: 1/4"=1'-0"
REFERENCED DRAWINGS: 1/MH401
CHWP
CHWP
ET
UH
HWP
HWP
RAF
B
BP
L-2
ET
L-1
OA INTAKE
6ø OA
4ø OA
4"Ø VENT
UP THROUGH
ROOF
MECHANICAL
A130
NIPR ROOM
A110
/2
O
A
/2
R
A
AFMA
20/20 OA
32/28 RA
L-5
24/16 OA
30/24 OA
17' - 6"
17' - 11"
15' - 10"
11' - 10"
15' - 8"
16' - 0"
5' - 2"
10' - 3"
4' - 7"
8' - 8"
24/18 EA
32/28 RA
AFMA
DOAS
AHU
28/24 OA
MH301
32/28 RA
34/28 SA
26/12 EA
GR-1 ON ROOF
D-12
D-11
D-2
GFS
ACP
1 BY P.C.
DHWH
BY P.C.
BY P.C.
BY P.C.
EF
CHWP
CHWP
ET
UH
HWP
HWP
5" CHWS&R
TO ACCU-1.
B
BP
ET
3/4" CHWR
5" CHWR
5" CHWR
AS
AS
4" HWS
4" HWS
4" HWS 5" CHWR
1 1/2" HWR
1 1/2" HWS 1" HWS
1" HWR
4" HWR
4" HWS
4" HWR
2" HWR
2" HWS
1 1/2" HWR
1 1/2" HWS
3" HWS
3" HWR
2 1/2" CHWR
2 1/2" CHWS
DOAS
AHU
MECHANICAL
A130
NIPR ROOM
A110
3" HWR
3" HWR
2 1/2" CHWR
2 1/2" CHWS
3" HWS
4" HWS
5" CHWS
4" HWS
"12" MAX
5" CHWR
3" CHWS
3" CHWR
3/4" HWS
GFS
ACP
DHWH
BY P.C.
BY P.C.
BY P.C.
BY P.C.
5" CHWR
3" CHWR
3" CHWS
KEY NOTES:
ERV-1 TO BE SUSPENDED UP HIGH. COORDINATE
WITHIN…
This is the start of the file's text. The full file is on GovTribe.