Plans 22031_Part2.pdf

PDF 4 MB Posted

Attached to
751/22031. ABG; Manistique Fire Shop at Wyman SF Nursery
Solicitation number
RFQ - 171 - 230000000095
Issued by
Schoolcraft County, Mayville Village, Michigan

About this file

This document contains plans and specifications for the construction of the Manistique Fire Shop Garage at the Wyman State Forest Nursery in Manistique, Michigan. The project is being bid by the Michigan Department of Natural Resources. The bid package includes architectural, mechanical, and plumbing drawings, as well as a detailed schedule of materials, equipment, and fixtures to be provided. The project is out for bid with a due date of December 5, 2022 and is anticipated to be awarded shortly thereafter. The contract will be for the full construction of the approximately 4,000 square foot fire garage facility, including a garage space, fire office, fire cache, and toilet room.

The bid documents outline detailed pricing and technical requirements for the project. Bidders will need to provide comprehensive pricing for all construction activities, including labor, materials, and equipment. There is an Alternate Bid #1 for additional insulation and radiant heating upgrades. No specific set-asides or incumbent contractors are mentioned. Funding for the project is provided by the Michigan Department of Natural Resources.

View the file

Other files

File Type Posted
Specifications 22031_Part2.pdf PDF
Addendum No. 2 FINAL.pdf PDF
Specifications 22031_Part3.pdf PDF
Plans 22031_Part1.pdf PDF
Advertisment 22031.pdf PDF
Specifications 22031_Part1.pdf PDF
Addendum 1 22031.pdf PDF
Plans 22031_Part3.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

0"

64' - 0"

10' - 0"

0"

20' - 0"

0" 8'

- 0

7' - 3"

62' - 5"

5"

A201

A2

A201 C2

A202

A2

A202C2

GARAGE

FIRE

CACHE

FIRE

OFFICE

TOILET

2' - 0"

2' - 0" 4' - 0"

A3 A203

C2 A203

A1 A203

102 103

104105106

1A

2A

1A

2A

2A

1A

4' - 0"4' - 8"

4' - 0"4' - 0"

A601C5

B5

A5

LADDER. REF DETAIL

AND

SECTIONS FOR

RAILING AND GATE

/A2 A301

A301B2

4:12 4:12

1"

67' - 1"

CONTIUNOUS

RIDGE VENT

A1 A203

EQUIPMENT

PLATFORM

LADDER. REF DETAIL

AND

SECTIONS FOR

RAILING AND GATE

/A2 A301

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

© U.P. Engineers & Architects, Inc.

PR

OJ

EC

T N

O:

DR

AW

N

BY

CH

EC

KE

D:

AP

PR

OV

ED

DE

SI

GN

ED

B Y:

w w w .u pe a.

co m

IS

SU

ED

F O R

D A

TE

P:

\M

-0

D

TM

B- M an is tiq ue

F ire

S ho p G ar ag e\ D w gs

\M

-0

-D

TM

B-

M

AN

IS

TI

Q U

E-

FI

R E-

SH

O

P.

rv t

/5

/2

8:

:1

AM

A101

BUILDING PLANS

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

MI

CH

IG

AN

D

EP

T.

OF

N

AT

UR

AL

R

ES

OU

RC

ES

MA

NI

ST

IQ

UE

, M I 4

M

-0

JH

R

JK

G

JK

G

JH

R

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T W

YM

A N

ST

A

TE

F O R

ES

T N U R

SE

R Y

M

IC

H

IG

A N D

EP

T.

O F N A

TU

R A L R

ES

O U R C

ES

1/4" = 1'-0"A3 FLOOR PLAN

1/8" = 1'-0"A1 ROOF PLAN

NN

1/4" = 1'-0"C1 EQUIPMENT PLATFORM PLAN

N

R

EV

IE

W

/2

0/

R

EV

IE

W

/2 1/

BI

D

SE

T

/5

/2

16' - 0"

7' - 1-1/2"

ATTIC ACCESS

PANEL

GARAGE

EQUIPMENT

PLATFORM

FAN, REF MECHANICAL (TYP)

LIGHT, REF ELECTRICAL (TYP)

RADIANT HEATER, REF

MECHANICAL. BASE BID

AND ALTERNATE #1

SHOWN ON PLAN, REF

MECHANICAL FOR

SEPARATE PLANS. (TYP)

8' - 0"

8' - 0"

8' - 0"

FIRE

CACHE

FIRE

OFFICE

TOILET

DIFFUSER, REF

MECHANICAL (TYP)

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

© U.P. Engineers & Architects, Inc.

PR

OJ

EC

T N

O:

DR

AW

N

BY

CH

EC

KE

D:

AP

PR

OV

ED

DE

SI

GN

ED

B Y:

w w w .u pe a.

co m

IS

SU

ED

F O R

D A

TE

P:

\M

-0

D

TM

B- M an is tiq ue

F ire

S ho p G ar ag e\ D w gs

\M

-0

-D

TM

B-

M

AN

IS

TI

Q U

E-

FI

R E-

SH

O

P.

rv t

/5

/2

8:

:2

AM

A102

REFLECTED

CEILING PLANS

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

MI

CH

IG

AN

D

EP

T.

OF

N

AT

UR

AL

R

ES

OU

RC

ES

MA

NI

ST

IQ

UE

, M I 4

M

-0

JH

R

JK

G

JK

G

JH

R

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T W

YM

A N

ST

A

TE

F O R

ES

T N U R

SE

R Y

M

IC

H

IG

A N D

EP

T.

O F N A

TU

R A L R

ES

O U R C

ES

1/4" = 1'-0"A3 REFLECTED CEILING PLAN

NN 1/4" = 1'-0"A1 OFFICE REFLECTED CEILING PLAN

R

EV

IE

W

/2

0/

R

EV

IE

W

/2 1/

BI

D

SE

T

/5

/2

12 ASPHALT SHINGLES

REF MECHANICAL FOR

EQUIPMENT (TYP)

REF ELECTRICAL FOR

LIGHTING (TYP)

REF PLUMBING FOR PLUMBING

FIXTURES (TYP)

BOLLARD

(TYP)

OVERHEAD DOOR. REF

SHEET A601 (TYP)MAN DOOR. REF SHEET

A601

METAL SIDING

CONTINUOUS RIDGE VENT

METAL SIDING

ASPHALT SHINGLES

REF MECHANICAL FOR

EQUIPMENT (TYP)

REF ELECTRICAL FOR

LIGHTING (TYP)

WINDOW. REF

SHEET A601REF PLUMBING FOR PLUMBING

FIXTURES (TYP)

BOLLARD

(TYP)

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

© U.P. Engineers & Architects, Inc.

PR

OJ

EC

T N

O:

DR

AW

N

BY

CH

EC

KE

D:

AP

PR

OV

ED

DE

SI

GN

ED

B Y:

w w w .u pe a.

co m

IS

SU

ED

F O R

D A

TE

P:

\M

-0

D

TM

B- M an is tiq ue

F ire

S ho p G ar ag e\ D w gs

\M

-0

-D

TM

B-

M

AN

IS

TI

Q U

E-

FI

R E-

SH

O

P.

rv t

/5

/2

8:

:2

AM

A201

BUILDING

ELEVATIONS

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

MI

CH

IG

AN

D

EP

T.

OF

N

AT

UR

AL

R

ES

OU

RC

ES

MA

NI

ST

IQ

UE

, M I 4

M

-0

JH

R

JK

G

JK

G

JH

R

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T W

YM

A N

ST

A

TE

F O R

ES

T N U R

SE

R Y

M

IC

H

IG

A N D

EP

T.

O F N A

TU

R A L R

ES

O U R C

ES

1/4" = 1'-0"A2 EAST ELEVATION

1/4" = 1'-0"C2 NORTH ELEVATION

R

EV

IE

W

/2

0/

R

EV

IE

W

/2 1/

BI

D

SE

T

/5

/2

12 ASPHALT SHINGLES

REF ELECTRICAL FOR

LIGHTING (TYP)

MAN DOOR. REF SHEET A601

BOLLARD

(TYP)

REF MECHANICAL FOR

LOUVERS

OVERHEAD DOOR. REF

SHEET A601

METAL SIDING

CONTINUOUS RIDGE VENT

REF PLUMBING FOR

PLUMBING FIXTURES

ASPHALT SHINGLES

REF ELECTRICAL FOR

LIGHTING (TYP)

METAL SIDING

BOLLARD (TYP)

REF PLUMBING FOR

PLUMBING FIXTURES (TYP)

MECHANICAL EQUIPMENT

EXHAUST/INTAKE, REF

MECHANICAL

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

© U.P. Engineers & Architects, Inc.

PR

OJ

EC

T N

O:

DR

AW

N

BY

CH

EC

KE

D:

AP

PR

OV

ED

DE

SI

GN

ED

B Y:

w w w .u pe a.

co m

IS

SU

ED

F O R

D A

TE

P:

\M

-0

D

TM

B- M an is tiq ue

F ire

S ho p G ar ag e\ D w gs

\M

-0

-D

TM

B-

M

AN

IS

TI

Q U

E-

FI

R E-

SH

O

P.

rv t

/5

/2

8:

:2

AM

A202

BUILDING

ELEVATIONS

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

MI

CH

IG

AN

D

EP

T.

OF

N

AT

UR

AL

R

ES

OU

RC

ES

MA

NI

ST

IQ

UE

, M I 4

M

-0

JH

R

JK

G

JK

G

JH

R

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T W

YM

A N

ST

A

TE

F O R

ES

T N U R

SE

R Y

M

IC

H

IG

A N D

EP

T.

O F N A

TU

R A L R

ES

O U R C

ES

1/4" = 1'-0"A2 WEST ELEVATION

1/4" = 1'-0"C2 SOUTH ELEVATION

R

EV

IE

W

/2

0/

R

EV

IE

W

/2 1/

BI

D

SE

T

/5

/2

T/FOOTING

96' - 8"

FFE

100' - 0"

TRUSS BRG

116' - 0 1/4"

A301 A4

GARAGE

STANDARD 2x4 LATERAL

BRACING NAILED TO TOP

OF BOTTOM CHORD AT

10'-0" MAX SPACING (TYP)

TWO (2) ROWS 2x6 VERTICAL

BRACING FOR LENGTH OF

BUILDING

NOTE: BRACING PROVIDED FOR

REFERENCE. CONTRACTOR

SHALL COORDINATE ALL

BRACING WITH TRUSS

MANUFACTURER.

1/4" METAL PANEL CEILING

ASPHALT SHINGLES

UNDERLAYMENT

ICE AND WATER SHIELD 3'-0" IN AROUND ENTIRE PERIMETER

5/8" PLYWOOD SHEATHING

PRE-ENGINEERED TRUSSES

CONTINUOUS RIDGE VENT

R-60 BATT INSUL

T/FOOTING

96' - 8"

FFE

100' - 0"

TRUSS BRG

116' - 0 1/4"

GARAGE

1/4" METAL PANEL CEILING

ASPHALT SHINGLES

UNDERLAYMENT

ICE AND WATER SHIELD 3'-0" IN AROUND ENTIRE PERIMETER

5/8" PLYWOOD SHEATHING

PRE-ENGINEERED TRUSSES

R-60 BATT INSUL

DROP TRUSS DROP TRUSS

2x6 LOOKOUTS @ 16" O.C.2x6 LOOKOUTS @ 16" O.C.

REF ELECTRICAL FOR

LIGHTS, TYP

REF STRUCTURAL

FOR DOOR LINTEL REF STRUCTURAL FOR

DOOR LINTEL

T/FOOTING

96' - 8"

FFE

100' - 0"

ROOM CEILING

108' - 0"

FIRE

CACHE

FIRE

OFFICE

TOILET

GARAGE

A301 A3

SELF-CLOSING GATE PER

SPECIFICATIONS INSTALLED PER

MANUFACTURER'S

RECOMMENDATIONS

2' - 0"

LADDER PER DETAIL /A2 A301RAILING ATTACHED

PER DETAIL /A3 A301

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

© U.P. Engineers & Architects, Inc.

PR

OJ

EC

T N

O:

DR

AW

N

BY

CH

EC

KE

D:

AP

PR

OV

ED

DE

SI

GN

ED

B Y:

w w w .u pe a.

co m

IS

SU

ED

F O R

D A

TE

P:

\M

-0

D

TM

B- M an is tiq ue

F ire

S ho p G ar ag e\ D w gs

\M

-0

-D

TM

B-

M

AN

IS

TI

Q U

E-

FI

R E-

SH

O

P.

rv t

/5

/2

8:

:2

AM

A203

BUILDING

SECTIONS

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

MI

CH

IG

AN

D

EP

T.

OF

N

AT

UR

AL

R

ES

OU

RC

ES

MA

NI

ST

IQ

UE

, M I 4

M

-0

JH

R

JK

G

JK

G

JH

R

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T W

YM

A N

ST

A

TE

F O R

ES

T N U R

SE

R Y

M

IC

H

IG

A N D

EP

T.

O F N A

TU

R A L R

ES

O U R C

ES

1/4" = 1'-0"A3 NORTH-SOUTH BUILDING SECTION

1/4" = 1'-0"C2 EAST-WEST BUILDING SECTION

1/4" = 1'-0"A1 SECTION @ ROOMS

R

EV

IE

W

/2

0/

R

EV

IE

W

/2 1/

BI

D

SE

T

/5

/2

T/FOOTING

96' - 8"

FFE

100' - 0"

TRUSS BRG

116' - 0 1/4"

3' - 0"

1'

- 0

1' - 6" OVHG

RIGID INSUL: TO R-20 FOR 24" IN (BASE BID)

TO R-25 FOR 48" IN AND R-10

UNDER ENTIRE SLAB (ALTERNATE)

6" SLAB ON GRADE w/ 6x6-6/6

WWF ON 6 MIL VAPOR BARRIER

8" CMU WALL REF

STRUCT FOR

REINFORCING

METAL SIDING

BUILDING WRAP

1/2" PLYWOOD SHEATHING

2x8 STUDS w/ BATT INSUL TO R-19

RIGID INSUL TO R-5

1/2" PLYWOOD SHEATHING

DOUBLE 2x8 TOP

PLATE

CONCRETE FOOTING.

REF STRUCT FOR

REINFORCING

1/4" METAL CEILING

ASPHALT SHINGLES

UNDERLAYMENT

ICE AND WATER SHIELD 3'-0" IN AROUND ENTIRE PERIMETER

5/8" PLYWOOD SHEATHING

PRE-ENGINEERED TRUSSES

INSULATION BAFFLE

BATT INSUL TO R-60

FASCIA AND 2x8

SUB-FASCIA

VENTED

SOFFIT

RIGID INSUL TO

R-15

PT 2x8 BOTTOM PLATE w/ 1/2" ANCHOR BOLTS x 12" LONG @ 48" O.C.

4"

EXTEND SIDING DOWN 3"

AND PROVIDE RODENT

CHANNEL

FFE

100' - 0"

ROOM CEILING

108' - 0"

2' - 0" 1'

- 0

1'

- 7

1/ 2"

1'

- 7

1/ 2"

PRE-FABRICATED METAL RAILING

w/ 1-1/2" Ø HORIZONTAL BARS AND 1" Ø VERTICAL POSTS w/ MIN

DIMENSIONS SHOWN.

1' - 6"

WELD RAILING

TO PLATE

CONTINUOUS x 10" x 1/2"

THICK STEEL PLATE

ATTACHED TO 2x10 w/ (2)

1/2" Ø LAG BOLTS

SPACED 24" O.C. DRILL

9/16" Ø HOLES IN PLATE

FOR LAG BOLTS

5/8" GWB CEILING

2x10 FLOOR JOIST (PROVIDE ADDITIONAL 2x10 FRAMING PER

FRAMING PLANS FOR RAILING

ATTACHMENT)

PT 2x6 BASEPLATE w/ 1/2" Ø x

10" LONG WEDGE ANCHORS

@ 24" O.C.

3'

- 6

5/8" PLYWOOD FLOOR

1"1'

1/

4" 1'

- 7 1/

4"

2'

- 6

MI

N

0"

M

AX

H

EI

GH

T

" M

IN

, 1

8" M

AX

" M

IN

, 1 4"

M

AX

(T

YP

6'

MA

X

SP

AC

IN

G

2 1/2"x3/8" SIDE RAILS

3/4" ⌀ SCH 40, STEEL

PIPE RUNGS (TYP)

OR 3/4" FLAT BARS

3"x1/4" BENT PLATE OR ANGLE w/ 1/2" ⌀ EPOXY ANCHORS w/ MIN 3 1/2" EMBEDMENT

(DEWALT AC 100+ GOLD OR

EQUAL)

1'

6" C

LR

2' - 6" CLR

2'

6" C

LR

NOTES

1. LADDERS SHALL MEET THE REQUIREMENTS

OF THE CURRENT MICHIGAN MECHANICAL CODE

AND THIS DETAIL. IN THE EVENT OF A CONFLICT,

THE STRICTEST PROVISION SHALL GOVERN.

2. ALL MATERIALS SHALL BE HOT-DIPPED

GALVANIZED.

3. FOR COMERCIALLY MANUFACTURED LADDERS,

PROVIDE MANUFACTURER CUT SHEET. FOR

CUSTOM LADDERS, PROVIDE STEEL SHOP

DRAWINGS.

4. PROVIDE LADDERS AS SHOWN ON THE PLANS

AND AT ROOF ELEVATION CHANGES OF 30" OR

GREATER.

5. MAX LADDER CAPACITY IS 350#.

LADDER PLAN

8 1/4"

CLEAR ZONE

PRE-FABRICATED

LADDER w/ SAME

SPACING AS RAILING

@ TOP RAILS. WELD

TO RAILING AS

SHOWNSELF-CLOSING POLE MOUNT

GATE INSTALLED PER

MANUFACTURER

RECOMMENDATIONS

2' - 0"

1/4"

TYP

REF BELOW FOR PLATE AND

CONNECTION

REF DETAIL BELOW FOR LADDER

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

© U.P. Engineers & Architects, Inc.

PR

OJ

EC

T N

O:

DR

AW

N

BY

CH

EC

KE

D:

AP

PR

OV

ED

DE

SI

GN

ED

B Y:

w w w .u pe a.

co m

IS

SU

ED

F O R

D A

TE

P:

\M

-0

D

TM

B- M an is tiq ue

F ire

S ho p G ar ag e\ D w gs

\M

-0

-D

TM

B-

M

AN

IS

TI

Q U

E-

FI

R E-

SH

O

P.

rv t

/5

/2

8:

:2

AM

A301

WALL SECTIONS

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

MI

CH

IG

AN

D

EP

T.

OF

N

AT

UR

AL

R

ES

OU

RC

ES

MA

NI

ST

IQ

UE

, M I 4

M

-0

JH

R

JK

G

JK

G

JH

R

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T W

YM

A N

ST

A

TE

F O R

ES

T N U R

SE

R Y

M

IC

H

IG

A N D

EP

T.

O F N A

TU

R A L R

ES

O U R C

ES

3/4" = 1'-0"A4 TYPICAL WALL SECTION

3/4" = 1'-0"A3 SECTION @ PLATFORM WALL

1/2" = 1'-0"A2 TYPICAL LADDER DETAIL

3/4" = 1'-0"B2 LADDER ELEVATION

R

EV

IE

W

/2

0/

R

EV

IE

W

/2 1/

BI

D

SE

T

/5

/2

F-1

SE

E

SC

H

ED

U

LE

SEE SCHEDULE

2"

2" 2"

F

SE

E

SC

HE

DU

LE

SEE SCHEDULE

OH

SE

E

SC

HE

DU

LE

SEE SCHEDULE

4'

- 0

3' - 0"

WINDOW SHALL BE

CASEMENT TYPE,

PLASTIC WINDOW PER

SPECIFICATIONS.

FLOOR

BOTTOM OF

STRUCTURE

CEILINGS WHERE

OCCURS

1 2

2x4 WOOD STUDS @ 16" O.C.

5/8" GWB EA SIDE

2x6 WOOD STUDS @ 16" O.C.

5/8" GWB EA SIDE

1A

2x4 WOOD STUDS @ 16" O.C.

5/8" GWB OFFICE / CACHE SIDE

5/8" OSB GARAGE SIDE

OFFICE OR

CACHE

GARAGE

2A

2x6 WOOD STUDS @ 16" O.C.

5/8" GWB TOILET, CACHE, OR OFFICE SIDE

5/8" OSB GARAGE SIDE

TOILET,

CACHE, OR

OFFICE

GARAGE

TOILET PAPER

DISPENCER

MOUNTED PER A001

GRAB BARS MOUNTED

PER A001 (TYP)

PAPER TOWEL

DISPENCER

MOUNTED PER A001

MIRROR MOUNTED

PER A001

SOAP DISPENCER

MOUNTED PER

A001

HARDWARE SETS

HARWARE SET 1:

3 EA HINGES

1 EA ENTRY LOCKSET

1 EA OVERHEAD STOP w/ INTEGRATED CLOSER

1 EA SWEEP

WEATHERSTRIPPING

HARWARE SET 2:

3 EA HINGES

1 EA STORAGE LOCKSET

1 EA OVERHEAD STOP

HARWARE SET 3:

3 EA HINGES

1 EA OFFICE LOCKSET

1 EA OVERHEAD STOP

HARWARE SET 4:

3 EA HINGES

1 EA PRIVACY LOCKSET

1 EA OVERHEAD STOP

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

© U.P. Engineers & Architects, Inc.

PR

OJ

EC

T N

O:

DR

AW

N

BY

CH

EC

KE

D:

AP

PR

OV

ED

DE

SI

GN

ED

B Y:

w w w .u pe a.

co m

IS

SU

ED

F O R

D A

TE

P:

\M

-0

D

TM

B- M an is tiq ue

F ire

S ho p G ar ag e\ D w gs

\M

-0

-D

TM

B-

M

AN

IS

TI

Q U

E-

FI

R E-

SH

O

P.

rv t

/5

/2

8:

:2

AM

A601

ARCHITECTURAL

SCHEDULES AND

DETAILS

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

MI

CH

IG

AN

D

EP

T.

OF

N

AT

UR

AL

R

ES

OU

RC

ES

MA

NI

ST

IQ

UE

, M I 4

M

-0

JH

R

JK

G

JK

G

JH

R

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T W

YM

A N

ST

A

TE

F O R

ES

T N U R

SE

R Y

M

IC

H

IG

A N D

EP

T.

O F N A

TU

R A L R

ES

O U R C

ES

ROOM FINISH SCHEDULE

ROOM

NO. ROOM NAME

FLOOR WALLS CEILING

REMARKSMATERIAL FINISH NORTH SOUTH EAST WEST MATERIAL FINISH HGT.

101 GARAGE CONC SEALED PNT-3 PNT-3 PNT-3 PNT-3 PRE-FINISHED METAL NONE 16' - 0"

102 TOILET CONC SEALED PNT-4 PNT-4 PNT-4 PNT-4 GWB PNT-2 8' - 0"

103 FIRE OFFICE CONC SEALED PNT-1 PNT-1 PNT-1 PNT-1 GWB PNT-2 8' - 0"

104 FIRE CACHE CONC SEALED PNT-1 PNT-1 PNT-1 PNT-1 GWB PNT-2 8' - 0"

105 EQUIPMENT PLATFORM PWD NONE PNT-3 PNT-3 PNT-3 PNT-3 PRE-FINISHED METAL NONE 7' - 1 1/2"

DOOR & FRAME SCHEDULE

DOOR

NO.

DOOR FRAME

HDWR

SET REMARKSTYPE MATERIAL

SIZE

ELEV MATERIALWIDTH HEIGHT

101 F HM 3' - 0" 7' - 0" F-1 HM 1 GALVANIZED AND INSULATED

102 OH STEEL 12' - 0" 14' - 0" FRAME AND HARDWARE BY OVERHEAD DOOR MFR

103 OH STEEL 14' - 0" 14' - 0" FRAME AND HARDWARE BY OVERHEAD DOOR MFR

104 OH STEEL 14' - 0" 14' - 0" FRAME AND HARDWARE BY OVERHEAD DOOR MFR

105 OH STEEL 12' - 0" 14' - 0" FRAME AND HARDWARE BY OVERHEAD DOOR MFR

106 OH STEEL 12' - 0" 14' - 0" FRAME AND HARDWARE BY OVERHEAD DOOR MFR

107 F HM 3' - 0" 7' - 0" F-1 HM 1 GALVANIZED AND INSULATED

108 F HM 3' - 0" 7' - 0" F-1 HM 4

109 F HM 3' - 0" 7' - 0" F-1 HM 3

110 F HM 3' - 0" 7' - 0" F-1 HM 2

DOOR FRAME TYPES DOOR TYPES

WINDOW TYPES

WALL TYPES

1/4" = 1'-0"C5 TLT NORTH ELEV

1/4" = 1'-0"B5 TLT EAST ELEV

1/4" = 1'-0"A5 TLT WEST ELEV

R

EV

IE

W

/2

0/

R

EV

IE

W

/2 1/

BI

D

SE

T

/5

/2

STM

STM

PLUMBING PIPING MECHANICAL PIPING

DUCTWORK

CDS

CDR

CHWS

CHWR

CDS

CDR

CHWR

CHWS

AIR

ST

G

G

AIR

HWR

HWR

HWS

HWS

FP

FP

C

C

ST

V

V

SAN

HWC

SAN

EA24x14

EA24x14

EA24x14

HW

CW

HWC

OA24x14

OA24x14

OA24x14

RA24x14

SA24x14

SA24x14

S D

SA24x14

RA24x14

RA24x14

CW

HW

STM

CDR

CDS

CHWR

CHWS

HWR

HWS

G

AIR

FP

C

ST

CW

V

SAN

HWC

HW

HYDRONIC HOT WATER SUPPLY - NEW

HYDRONIC HOT WATER SUPPLY - EXISTING

HYDRONIC HOT WATER SUPPLY - DEMO

HYDRONIC HOT WATER RETURN - NEW

HYDRONIC HOT WATER RETURN - EXISTING

HYDRONIC HOT WATER RETURN - DEMO

COMPRESSED AIR - NEW

COMPRESSED AIR - EXISTING

COMPRESSED AIR - DEMO

GAS - NEW

GAS - EXISTING

GAS - DEMO

DOMESTIC COLD WATER - EXISTING

DOMESTIC COLD WATER - DEMO

DOMESTIC COLD WATER - NEW

DOMESTIC HOT WATER - EXISTING

DOMESTIC HOT WATER - DEMO

DOMESTIC HOT WATER - NEW

DOMESTIC HOT WATER RECIRC - EXISTING

DOMESTIC HOT WATER RECIRC DEMO

DOMESTIC HOT WATER RECIRC - NEW

SANITARY - EXISTING

SANITARY - DEMO

SANITARY - NEW

VENT - EXISTING

VENT - DEMO

VENT - NEW

STORM - EXISTING

STORM - DEMO

STORM - NEW

CONDENSATE - EXISTING

CONDENSATE - DEMO

CONDENSATE - NEW

FIRE PROTECTION - EXISTING

FIRE PROTECTION - DEMO

FIRE PROTECTION - NEW

ABBREVIATIONS

PIPING "T"

PIPING 90

STRAINER

SYMBOL LEGEND

CAP

NOTES

INLINE PUMP

BALANCE VALVE

PRESSURE RELIEF VALVE

3-WAY CONTROL VALVE

2-WAY CONTROL VALVE

GLOBE VALVE

GATE VALVE

CHECK VALVE

CIRCUIT SETTER

BUTTERFLY VALVE

BALL VALVE

EXHAUST AIR DUCT DOWN

EXHAUST AIR DUCT UP

RETURN AIR DUCT DOWN

RETURN AIR DUCT UP

SUPPLY AIR DUCT DOWN

SUPPLY AIR DUCT UP

AIR FLOW

HUMIDISTAT - 60" A.F.F.

THERMOSTAT - 60" A.F.F.

DUCT SMOKE DETECTOR

MOTORIZED DAMPER

FIRE / SMOKE DAMPER

(RATING DETERMINED BY WALL TYPE)

VOLUME CONTROL DAMPER

SQUARE TO ROUND TRANSITION

RETURN OR EXHAUST REGISTER

SUPPLY REGISTER

RELIEF AIR HOOD - ROOF

FRESH AIR INTAKE HOOD - ROOF

EXHAUST FAN - ROOF

RETURN OR EXHAUST AIR GRILLE

LINEAR DIFFUSER

SUPPLY AIR DIFFUSER PIPE BREAK

PIPE DOWN

PIPE UP

CLEAN OUT

GAS METER

UNION

HOSE BIBB

ELECTRIC BELL

SIAMESE CONNECTION

BARE FIN TUBE ELEMENT

FIN TUBE ELEMENT WITH COVER

EXTERNALLY INSULATED DUCTWORK

INTERNALLY LINED DUCTWORK

SUPPLY AIR DUCT - EXISTING

SUPPLY AIR DUCT - DEMO

SUPPLY AIR DUCT - NEW

RETURN AIR DUCT - EXISTING

RETURN AIR DUCT - DEMO

RETURN AIR DUCT - NEW

OUTSIDE AIR DUCT - EXISTING

OUTSIDE AIR DUCT - DEMO

OUTSIDE AIR DUCT - NEW

EXHAUST AIR DUCT - EXISTING

EXHAUST AIR DUCT - DEMO

EXHAUST AIR DUCT - NEW

CONDENSOR WATER SUPPLY

CONDENSOR WATER RETURN

CHILLED WATER SUPPLY

CHILLED WATER RETURN

CONDENSOR WATER SUPPLY - DEMO

CONDENSOR WATER SUPPLY - EXIST

CONDENSOR WATER RETURN - DEMO

CONDENSOR WATER RETURN - EXIST

CHILLED WATER SUPPLY - DEMO

CHILLED WATER SUPPLY - EXIST

CHILLED WATER RETURN - DEMO

CHILLED WATER RETURN - EXIST

METER

STEAM - NEW

STEAM - EXISTING

STEAM - DEMO

CONNECTION TO EXISTING

ACCU AIR COOLED CONDENSING UNIT

AFF ABOVE FINISHED FLOOR

AHU AIR HANDLING UNIT

AI ANALOG INPUT

AO ANALOG OUTPUT

APD AIR PRESSURE DROP

AS AIR SEPERATOR

B BOILER

BB BASEBOARD

BC BOOSTER COIL

BDD BACKDRAFT DAMPER

BFG BELOW FINISHED GRADE

BFP BACKFLOW PREVENTER

BHP BRAKE HORSE POWER

BOD BOTTOM OF DUCT

BOP BOTTOM OF PIPE

BT BATH TUB

BTU BRITISH THERMAL UNITS

BTUH BRITISH THERMAL UNITS PER HOUR

C CONVECTOR

CA COMPRESSED AIR

CB CATCH BASIN

CC COOLING COIL

CCF 100 CUBIC FEET

CD CEILING DIFFUSER

CF CUBIC FEET

CFH CUBIC FEET PER HOUR

CFM CUBIC FEET PER MINUTE

CFP CLEAN OUT FERRULE AND PLUG

CH CHILLER

CI CAST IRON

CHWR CHILLED WATER RETURN

CHWS CHILLED WATER SUPPLY

CO CLEAN OUT

CO CARBON MONOXIDE

COND CONDENSATE

CO2 CARBON DIOXIDE

CT COOLING TOWER

CU CONDENSING UNIT

CU FT CUBIC FOOT

CUH CABINET UNIT HEATER

CW COLD WATER

CWR CONDENSER WATER RETURN

CWS CONDENSER WATER SUPPLY

D DIFFUSER

DB DRY BULB

DEG F DEGREE FAHRENHEIT

DF DRINKING FOUNTAIN

DI DIGITAL INPUT

DIA DIAMETER

DN DOWN

DO DIGITAL OUTPUT

DWV DRAIN, WASTE AND VENT

EA EACH

EAT ENTERING AIR TEMPERATURE

EC ELECTRICAL CONTRACTOR

EF EXHAUST FAN

EG EXHAUST AIR GRILLE

ELEV ELEVATION

ER EXHAUST AIR REGISTER

EUH ELECTRIC UNIT HEATER

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WATER HEATER

EWT ENTERING WATER TEMPERATURE

EX EXISTING

EXH EXHAUST

F FURNACE

FAI FRESH AIR INTAKE

FBO FURNISHED BY OTHERS

FC FAN COIL

FD FLOOR DRAIN

FD FIRE DAMPER

FIN FIN TUBE RADIATION

FLG FLANGE

FP FIRE PROTECTION

FPM FEET PER MINUTE

FT FOOT OR FEET

F&T FLOAT AND THERMOSTATIC TRAP

G GAS (NATURAL)

GAL GALLON

GC GENERAL CONTRACTOR

GPH GALLONS PER HOUR

GPM GALLONS PER MINUTE

GT GREASE TRAP

H HYDROGEN

HB HOSE BIBB

HC HEATING COIL

HCO HORIZONTAL CLEANOUT

HP HORSE POWER

HTR HEATER

HVAC HEATING, VENTILATING & AIR COND

HW HOT WATER

HWC HOT WATER RECIRCULATING

HWR HOT WATER RETURN

HWS HOT WATER SUPPLY

HX HEAT EXCHANGER

IE INVERT ELEVATION

IF INLINE FAN

IN INCH OR INCHES

IP IRON PIPE

INV INVERT

IWH INSTANTANEOUS WATER HEATER

JAN JANITOR

JC JANITOR'S CLOSET

JS JANITOR'S SINK

LAT LEAVING AIR TEMPERATURE

LAV LAVATORY

LBS POUNDS

LHWR LOW TEMPERATURE HOT WATER

RETURN

LHWS LOW TEMPERATURE HOT WATER

SUPPLY

LIQ LIQUID (REFRIGERATION)

LV LOUVER

LP PROPANE GAS (LIQUID)

LWT LEAVING WATER TEMPERATURE

M METER

MAU MAKE-UP AIR HANDLING UNIT

MAX MAXIMUM

MB MOP BASIN

MBH BRITISH THERMAL UNITS (1000)

MBTUH BRITISH THERMAL UNITS (1000)

MC MECHANICAL CONTRACTOR

MCA MINIMUM CIRCUIT AMPACITY

MD MOTORIZED DAMPER

MECH MECHANICAL

MIN MINIMUM

MOCP MAXIMUM OVER CURRENT

PROTECTION

OA OUTDOOR AIR

OAI OUTDOOR AIR INTAKE

OC ON CENTER

OD OVERFLOW DRAIN

ODP OPEN DRIP PROOF

OXY OXYGEN

P PUMP

PC PLUMBING CONTRACTOR

PD PNEUMATIC OPERATED DAMPER

PIV POST INDICATING VALVE

PRV PRESSURE REDUCING VALVE

PT PRESSURE TEMPERATURE PLUG

PTAC PACKAGED TERMINAL AIR COND. UNIT

PVAC PROCESS VACUUM

S SINK

SA SUPPLY AIR

SAD SUPPLY AIR DIFFUSER

SAF SUPPLY AIR FAN

SAN SANITARY SEWER

SD SMOKE DETECTOR

SG SUPPLY AIR GRILLE

SH SHOWER HEAD

SHC STEAM HEATING COIL

SR SUPPLY REGISTER

SS STAINLESS STEEL

ST STORM

STM STEAM

SUCT SUCTION (REFRIGERATION)

TCC TEMPERATURE CONTROL CONTRACTOR

TCD TEMPERATURE CONTROL DAMPER

TCP TEMPERATURE CONTROL PANEL

TD TRANSFER DUCT

TG TRANSFER AIR GRILLE

TT THERMOSTATIC TRAP

TYP TYPICAL

UG UNDERGROUND

UH UNIT HEATER

UV UNIT VENTILATOR

V VENT

VAC VACUUM

VAV VARIABLE AIR VOLUME BOX

VD VOLUME DAMPER

VFD VARIABLE FREQUENCY DRIVE

VS VENT STACK (SANITARY)

VTR VENT THRU ROOF (SANITARY)

VUV VERTICAL UNIT VENTILATOR

W WASTE

WB WET BULB

WC WATER CLOSET

W/O WITHOUT

WH WATER HEATER

WSHP WATER SOURCE HEAT PUMP

NOTE:

NOT ALL ABBREVIATIONS AND/OR SYMBOLS ARE

USED IN THIS SET OF DOCUMENTS.

N2O NITROUS OXIDE

NC NORMALLY CLOSED

NIC NOT INCLUDED OR NOT IN CONTRACT

NIT NITROGEN

NO NORMALLY OPEN

KW KILOWATT

R REGISTER

RA RETURN AIR

RD ROOF DRAIN

RET RETURN

RF RETURN FAN

RG RETURN AIR GRILLE

RPZ REDUCED PRESSURE ZONE BACKFLOW PREVENTER

RR RETURN REGISTER

RTU ROOF TOP UNIT

MECHANICAL/PLUMBING AND FIRE PROTECTION GENERAL NOTES

1. THE CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, MATERIALS AND OPERATIONS AND

PERFORM ALL LABOR REQUIRED FOR INSTALLATIONS AS INDICATED THE DRAWINGS, IN THE

SPECIFICATIONS AND AS REQUIRED BY LOCAL, STATE AND FEDERAL CODES, AND AS MAY BE

REASONABLY IMPLIED TO ACCOMPLISH COMPLETE MECHANICAL SYSTEMS.

2. ALL CLOSE ELECTRICAL DISCONNECTS REQUIRED PER NEC CODE SHALL BE FURNISHED AND

INSTALLED BY THE ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE.

3. CONTRACTOR SHALL PROVIDE PRODUCTS AS SPECIFIED ON THE DRAWINGS AND

SPECIFICATIONS, HOWEVER, WHERE THE WORDS "EQUAL TO" ARE USED, ADDITIONAL PRODUCTS

MAY BE SUBMITTED AS PROPOSED SUBSTITUTIONS, BUT REQUIRE APPROVAL FROM

ARCHITECT/ENGINEER.

4. DESIGN DRAWINGS SHOW GENERAL ARRANGEMENT AND EXTENT OF WORK. THE DRAWINGS

ARE DIAGRAMMATIC AND MAY NOT NECESSARILY BE DRAWN TO SCALE FOR PURPOSE OF CLARITY AND LEGIBILITY. IT IS INTENDED THAT ALL ITEMS BE LOCATED SYMMETRICALLY WITH ARCHITECTURAL

ELEMENTS WHERE FEASIBLE AND BE INSTALLED TO AVOID OBSTRUCTIONS AND PRESERVE

HEADROOM. CONTRACTOR SHALL REVIEW PLANS OF OTHER TRADES WITH HIS OWN WORK TO AVOID CONFLICTS AND INTERFERENCES. CONTRACTOR MUST MAKE USE OF ALL SOURCES OF INFORMATION

INCLUDING DRAWINGS OF EQUIPMENT FURNISHED BY OTHERS. FAILURE TO REVIEW WORKING

SPACES OR CHECK DIMENSIONS IN QUESTION SHALL NOT WARRANT CONFLICTS. DRAWINGS AND

SPECIFICATIONS ARE INTENDED TO BE COMPLIMENTARY.

5. MOTORS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR AS REQUIRED BY THE

EQUIPMENT FURNISHED BY THE MECHANICAL CONTRACTOR. MOTORS TO BE SUITABLE FOR LOAD, DUTY, VOLTAGE, FREQUENCY, HAZARD, SERVICE AND LOCATION INTENDED. SINGLE PHASE MOTORS MUST HAVE INTEGRAL THERMAL OVERLOAD PROTECTION IN ADDITION TO THAT PROVIDED IN MOTOR

CONTROLLERS. MOTORS TO CONFORM IN DESIGN AND PERFORMANCE TO THE MOTOR STANDARDS

OF NEMA. MOTORS RATED FOR CONTINUOUS DUTY UNDER FULL LOAD WITH A MAXIMUM

TEMPERATURE RISE OF 105 DEG F FOR OPEN, 125 DEG F FOR DRIP PROOF AND 130 DEG F FOR

EXPLOSION PROOF AND TOTALLY ENCLOSED TYPES. SUPPLY MOTORS WITH BELT DRIVES WITH

ADJUSTABLE BASES, REMOVABLE BELT GUARDS AND VARIABLE PITCH DRIVE PULLEY SELECTED SO THAT MIDPOINT OF VARIABLE RANGE OF PULLEY WILL DRIVE EQUIPMENT AT RATED SPEED. MOTORS

1 HP AND LARGER SHALL BE THREE PHASE (UNLESS OTHERWISE LISTED).

6. MOTOR CONTROLLERS SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR FOR

MOTORS FURNISHED BY THE MECHANICAL CONTRACTOR. MOTOR CONTROLLERS SHALL BE OF SIZES AND TYPES AS NEEDED TO MEET THE OPERATIONAL CONDITIONS AS REQUIRED BY THE SEQUENCE OF OPERATION. ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL THE POWER CIRCUIT, LOCAL

DISCONNECT AND CONNECTION TO MOTOR TERMINALS. MECHANICAL CONTRACTOR TO MOUNT

MOTOR CONTROLLERS AND CONTROL COMPONENTS AND WIRE AND MAKE ALL FINAL CONTROL

CONNECTIONS BETWEEN DEVICES.

7. THE DRAWINGS INDICATE KNOWN UTILITY AND DRAINAGE LINES IN ACCORDANCE WITH THE

INFORMATION FURNISHED TO THE ENGINEER. RESPONSIBILITY FOR LOCATING, UNCOVERING,

DISPOSING OR MAINTAINING ALL EXISTING UTILITY LINES TO REST SOLELY WITH THE CONTRACTOR.

VERIFY LOCATIONS AND DEPTHS OF SERVICE CONNECTION POINTS BEFORE PROCEEDING WITH

CONSTRUCTION.

8. CONTRACTOR SHALL CHECK EXISTING PREMISES BEFORE SUBMISSION OF BIDS TO CHECK

ALL CONDITIONS WHICH MAY EFFECT THE PERFORMANCE OF THE WORK INVOLVED. NO

ALLOWANCES OR EXTRA PAYMENT WILL BE MADE DUE TO CONTRACTOR'S FAILURE TO EXAMINE SITE

AND FULLY DISCERN WORKING CONDITIONS.

9. MECHANICAL CONTRACTOR SHALL RECEIVE, PROPERLY HOUSE, HANDLE, HOIST, AND

DELIVER TO PROPER LOCATION EQUIPMENT AND OTHER MATERIALS REQUIRED FOR THIS CONTRACT.

10. THE CONTRACTOR SHALL OBTAIN PERMITS, ARRANGE FOR INSPECTIONS, AND PAY FEES AND EXPENSES IN CONNECTION THEREWITH, AS A PART OF THE WORK REQUIRING SUCH PERMITS. EVERY

EFFORT IS MADE TO DESCRIBE THE WORK REQUIREMENTS IN CONFORMITY WITH APPLICABLE

CODES.

11. THE CONTRACTOR SHALL REVIEW ANY ALTERNATES OF OTHER TRADES, AND PRICE THEIR BID

TO ACCOUNT FOR ITEMS AFFECTING HIS WORK.

12. PIPING PASSING THROUGH CORRIDORS, TUNNELS, CHASES, ETC. SHALL BE CONSIDERED FOR

PROPER DRAINAGE. CONSULT WITH THE OTHER CONTRACTORS AND AVOID CONFLICT WITH

LOCATION OF PIPING. ORDER OF PRIORITY FOR ALL PIPING AND CONDUITS TO BE INSTALLED SHALL

BE AS FOLLOWS WITH THE HIGHEST PRIORITY LISTED FIRST.

A. PLUMBING DRAIN LINES

B. CONDENSATE LINES

C. DUCTWORK

D. FIRE PROTECTION

E. HOT AND COLD WATER PIPING

F. ELECTRICAL CONDUIT

13. WORK ASSIGNMENTS INFERRED BY THE DRAWINGS AND NOTES INCLUDED IN THESE PROJECT

DOCUMENTS ARE INFORMATIONAL ONLY AND ARE NOT INTENDED TO RELIEVE THE BIDDING

CONTRACTOR OF HIS OBLIGATION TO THE OWNER TO PROVIDE A COMPLETE AND COORDINATED

PROJECT. COMPREHENSIVE SUBCONTRACTOR COORDINATION AND FINAL WORK ASSIGNMENTS TO

SUBCONTRACTORS ARE THE SOLE RESPONSIBILITY OF THE BIDDING CONTRACTOR.

14. ALL DUCTS SERVING SUPPLY, RETURN AND EXHAUST TERMINALS SHALL BE PROVIDED WITH

BALANCE DAMPERS. FOR CLARITY, ALL DAMPERS MAY NOT BE SHOWN ON PLANS.

M

M

H

T

M

OD

OD

OD

OVERFLOW STORM - EXISTING

OVERFLOW STORM - DEMO

OVERFLOW STORM - NEW

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

© U.P. Engineers & Architects, Inc.

PR

OJ

EC

T N

O:

DR

AW

N

BY

CH

EC

KE

D:

AP

PR

OV

ED

DE

SI

GN

ED

B Y:

w w w .u pe a.

co m

IS

SU

ED

F O R

D A

TE

P:

\M

-0

D

TM

B- M an is tiq ue

F ire

S ho p G ar ag e\ D w gs

\M ec ha ni ca l\M

-0

-D

TM

B- M

AN

IS

TI

Q

U E-

FI

R

E-

SH

O P_

M ec ha ni ca l.r vt

/5

/2

8:

:0

AM

P001

MECHANICAL AND

PLUMBING

ABBREVIATIONS

AND SYMBOLS

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

MI

CH

IG

AN

D

EP

T.

OF

N

AT

UR

AL

R

ES

OU

RC

ES

MA

NI

ST

IQ

UE

, M I 4

M

-0

SP JG JGSP

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

M

IC

H

IG

A N D

EP

T.

O F N A

TU

R A L R

ES

O U R C

ES

R

EV

IE

W

/2

0/

R

EV

IE

W

/2 2/

BI

D

SE

T

/5

/2

TO SANITARY SERVICE

(SEE SITE PLAN FOR

CONTINUATION)

3" SAN UP

2" SAN UP

3" SAN UP 2" V UP

SS-1

L-1

WC-1

FIRE

CACHE

FIRE

OFFICE

GARAGE

TOILET

EW-1

WATER SERVICE

(SEE SITE PLAN FOR

CONTINUATION)

1¼" CW UP

3" SAN UP

2" V UP

3"ø

3" SAN DN

2" SAN DN

½" HW, CW DN

3" SAN DN

2" V UP/DN

SS-1

L-1

WC-1 3" VTR

HB-1

HB-1

HB-1

1¼" CW UP/DN

¾" CW DN

½" HW DN

½" CW DN

1¼" V UP

½" HW, CW DN

3/4"ø

3/4"ø

CW

CW

MX-1

EW-1

2" SAN UP

3" SAN DN

2" SAN UP

1¼" V UP

GARAGE

FIRE

CACHE

FIRE

OFFICE

TOILET

1021" CW UP

¾" HW UP

2" V UP

2" V UP/DN

EWH-1

3"ø

1¼" CW DN

¾" HW, CW TO WH

SEE PLUMBING PLAN

FOR CONTINUATION.

3/4"ø

SEE PLUMBING PLAN

FOR CONTINUATION.

SEE PLUMBING PLAN

FOR CONTINUATION.

3/ 4" ø

1" CW DN

¾" HW DN

FD-1

2" V DN

¾" CW DN

½" HW DN

1¼" V DN

1½" V UP

2" V DN

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

© U.P. Engineers & Architects, Inc.

PR

OJ

EC

T N

O:

DR

AW

N

BY

CH

EC

KE

D:

AP

PR

OV

ED

DE

SI

GN

ED

B Y:

w w w .u pe a.

co m

IS

SU

ED

F O R

D A

TE

P:

\M

-0

D

TM

B- M an is tiq ue

F ire

S ho p G ar ag e\ D w gs

\M ec ha ni ca l\M

-0

-D

TM

B- M

AN

IS

TI

Q

U E-

FI

R

E-

SH

O P_

M ec ha ni ca l.r vt

/5

/2

8:

:0

AM

P101

PLUMBING PLAN

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

MI

CH

IG

AN

D

EP

T.

OF

N

AT

UR

AL

R

ES

OU

RC

ES

MA

NI

ST

IQ

UE

, M I 4

M

-0

SP JG JGSP

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

M

IC

H

IG

A N D

EP

T.

O F N A

TU

R A L R

ES

O U R C

ES

1/8" = 1'-0"A1 UNDERLSAB PLUMBING PLAN

1/8" = 1'-0"A4 PLUMBING PLAN

1/8" = 1'-0"A3 PLATFORM PLUMBING PLAN

N N N

R

EV

IE

W

/2

0/

R

EV

IE

W

/2 2/

BI

D

SE

T

/5

/2

MX-1

EW-1

WC-1SS-1

HB-1 HB-1

HB-1

WH-1

3/4"ø

1/

4" ø

1/

4" ø

1 1/4"ø

3/4"ø

1"ø

3/4"ø

3/ 4" ø

1/ 2" ø

CW

CW

H

W

H

WCW

WATER SERVICE. SEE SITE

PLAN FOR CONTINUATION

1"ø

3/4"ø

3" ø

3"ø

2"ø

3"ø

2" ø

3"ø

SANITARY SERVICE. SEE SITE

PLAN FOR CONTINUATION

3" VTR

V

SS-1

L-1

EW-1

MX-1

2"ø

2"ø

FD-1

1 1/2"ø

1 1/4"ø

2"ø

WC-1

3"ø

3"ø

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

© U.P. Engineers & Architects, Inc.

PR

OJ

EC

T N

O:

DR

AW

N

BY

CH

EC

KE

D:

AP

PR

OV

ED

DE

SI

GN

ED

B Y:

w w w .u pe a.

co m

IS

SU

ED

F O R

D A

TE

P:

\M

-0

D

TM

B- M an is tiq ue

F ire

S ho p G ar ag e\ D w gs

\M ec ha ni ca l\M

-0

-D

TM

B- M

AN

IS

TI

Q

U E-

FI

R

E-

SH

O P_

M ec ha ni ca l.r vt

/5

/2

8:

:0

AM

P401

PLUMBING

ISOMETRICS

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

MI

CH

IG

AN

D

EP

T.

OF

N

AT

UR

AL

R

ES

OU

RC

ES

MA

NI

ST

IQ

UE

, M I 4

M

-0

SP JG JGSP

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

M

IC

H

IG

A N D

EP

T.

O F N A

TU

R A L R

ES

O U R C

ES

B1 DOMESTIC WATER ISOMETRIC

A3 DWV ISOMETRIC

R

EV

IE

W

/2

0/

R

EV

IE

W

/2 2/

BI

D

SE

T

/5

/2

STRAINER PER

SCHEDULE

TRAP SEAL

"QUAD-CLOSE" BY

J.R.SMITH MFG. CO.

FLOOR DRAIN BODY WITH

ADJUSTABLE STRAINER

AND

MEMBRANE CLAMP PER

SCHEDULE

PVC DRAIN PIPING TO MAIN

(SEE PLAN FOR SIZE)

FLOOR DRAIN W/TRAP SEAL

SEAL AROUND

OPENING

LOOSE-KEY

OPERATIONHOSE

CONNECTION

WITH VACUUM

BREAKER

WALL

BRACKET

SHUT-OFF VALVE

WITH ACCESS PANEL

3/4"MIN. SUPPLY

UNLESS NOTED

OTHERWISE

PIPE SUPPORT

EXTERIOR WALL

OR UNHEATED SPACE.

VERIFY FINISH.

VERIFY WALL THICKNESS

INTERIOR HEATED SPACE

SEAL OPENING

34"

8"

27"

FAUCET

WATTS USG-B

THERMOSTATIC

MIXING VALVE

WATTS USG-B

THERMOSTATIC MIXING

VALVE

FLEXIBLE SUPPLY

LINES (TYP.)

CHROME P-TRAP

WITH OUTLET

AND TRAP WRAP

CHROME P-TRAP WITH

OUTLET AND TRAP

WRAP

PROVIDE ADA WRAP ON ALL

SUPPLY LINES AND P-TRAP M

H C

9"

6" MAX.

MIXED WATER

SUPPLY TO FAUCET

FAUCET

1/4 TURN ANGLE

SHUT-OFF VALVE

W/ ESCUTCHEON

HANGER ROD

ADJUSTING NUT

'UL' LISTED

CLEVIS HANGER

PIPE SHIELD WITH

HEAVY DENSITY

INSULATION OR

PROTECTION

SADDLE.

SECTION

ELEVATION

PIPE

PIPE

INSULATION AND

COVERING

GALVANIZED AND MINIMUM

12" LONG. PIPE COVERING

SHIELD, 18 GAUGE.

FLARED ENDS WHERE

HEAVY DENSITY INSULATION

SADDLES ARE USED.

STAINLESS STEEL

ACCESS COVER

WITH SCREW

WALL

CLEAN-OUT TEE

WITH BRASS PLUG

1'-6"

FLOOR

LONG SWEEP PVC FITTINGS

OR 45° FITTING

SANITARY SEWER PIPING

HOSE-END DRAIN VALVE

TEMPERATURE AND

PRESSURE RELIEF VALVE

DIELECTRIC UNIONS

(TYPICAL)

CWHW

STEM THERMOMETER (TYP)

WATER HEATER

(SEE SCHEDULE)

SOAP STONE (MIN OF 3)

SECONDARY DRAIN PAN

MINIMUM OF 24" FROM

ANY WALL OR

STRUCTURE

ROOF CONSTRUCTION

AS INDICATED ON PLANS

INCREASER IF REQUIRED

VENT PIPE

12"

MINIMUM

HEIGHT

C L

1. VENT THRU ROOF (VTR) FOR PIPE

SIZES SMALLER THAN 3" MUST BE

INCREASED TO MINIMUM OF 3".

2. INCREASE IN PIPE DIAMETER MUST BE

MADE A MINIMUM OF 12" INSIDE THE

BUILDING.

FRICTION FIT NEOPRENE COLLAR

METAL CONE FLASHING

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

© U.P. Engineers & Architects, Inc.

PR

OJ

EC

T N

O:

DR

AW

N

BY

CH

EC

KE

D:

AP

PR

OV

ED

DE

SI

GN

ED

B Y:

w w w .u pe a.

co m

IS

SU

ED

F O R

D A

TE

P:

\M

-0

D

TM

B- M an is tiq ue

F ire

S ho p G ar ag e\ D w gs

\M ec ha ni ca l\M

-0

-D

TM

B- M

AN

IS

TI

Q

U E-

FI

R

E-

SH

O P_

M ec ha ni ca l.r vt

/5

/2

8:

:1

AM

P501

PLUMBING DETAILS

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

MI

CH

IG

AN

D

EP

T.

OF

N

AT

UR

AL

R

ES

OU

RC

ES

MA

NI

ST

IQ

UE

, M I 4

M

-0

SP JG JGSP

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

M

IC

H

IG

A N D

EP

T.

O F N A

TU

R A L R

ES

O U R C

ES

NOT TO SCALEC1 FLOOR DRAIN DETAIL

NOT TO SCALEA1 HOSE BIBB DETAIL

NOT TO SCALEC2 MIXING VALVE DETAIL

NOT TO SCALEB1 PIPE HANGER DETAIL

NOT TO SCALED4 WALL CLEANOUT DETAIL

NOT TO SCALEC4 WATER HEATER PIPING DIAGRAM

NOT TO SCALEB3 VENT THROUGH ROOF DETAIL

PLUMBING FIXTURE SCHEDULE

ID ADA DESCRIPTION MANUFACTURER MODEL

NUMBER

MATERIAL BASIN

DIMENSIONS

(IN)

TRIM MANUF. TRIM MODEL HOT WATER

(IN)

COLD WATER

(IN)

SANITARY (IN) NOTES

EW-1 - WALL MOUNT EMERGENCY EYE WASH STATION BRADLEY CORPORATION S19-220 PLASTIC - - - - - 1-1/4" 3,5 FD-1 - 6" DIAMETER FLOOR DRAIN WITH TRAP SEAL ZURN Z415B CAST IRON 6" - - - - PER PLAN 2 HB-1 - AUTOMATIC DRAINING HOSE BIBB WITH VACUUM BREAKER WOODFORD 67 BRASS - - - - 3/4" - L-1 YES WHEELCHAIR ACCESSIBLE WALL MOUNT LAVATORY KOHLER K-2005 VITREOUS CHINA 16x10 KOHLER K-15199-4NDRA 1/2" 1/2" 1-1/2" 4 MX-1 - THERMOSTATIC MIXING VALVE BRADLEY CORPORATION S19-2000 - - - - 1/2" 1/2" - 6 SS-1 - FLOOR MOUNTED MOP SINK MUSTEE 63M FIBERGLASS 24x24 MUSTEE 63.600A 1/2" 1/2" - 7 WC-1 YES FLOOR MOUNT FLUSH TANK WATER CLOSET KOHLER K-3658 VITREOUS CHINA - - - - 1/2" 3 8 WCO-1 - WALL CLEANOUT WITH STAINLESS STEEL COVER AND PLUG ZURN Z1468 STAINLESS STEEL - - - - - PER PLAN

1. PROVIDE THERMOSTATIC MIXING VALVE AND TRAP WRAPS PER ADA REQUIREMENTS.

2. PROVIDE WITH TRAP SEAL EQUAL TO "QUAD-CLOSE" BY J.R. SMITH.

3. PROVIDE WITH SEPARATE MIXING VALVE MX-1 PER SCHEDULE.

4. MOUNT PLUMBING FIXTURE PER ADA REQUIREMENTS.

5. PROVIDE 1/2" TEMPERED WATER FROM MIXING VALVE.

6. PROVIDE WITH SURFACE MOUNT STAINLESS STEEL CABINET.

7. PROVIDE WITH HOSE AND HOSE HOLDER (65.700) AND WALL GUARDS (67.2424).

8. PROVIDE WITH OPEN FRONT ELONGATED PLASTIC SEAT.

PLUMBING PIPE INSULATION SCHEDULE

SYSTEM TYPE INSUL.

TYPE

PIPE SIZES INSULATION

THICKNESS

DOMESTIC HOT WATER SUPPLY P-1 ALL SIZES 1"

DOMESTIC COLD WATER P-1

P-5

1-1/4" AND SMALLER

1-1/2" AND LARGER

1-1/2" 1"

PIPING INSULATION SCHEDULE

INSULATION

TYPE

DESCRIPTION

P-1 ASTM C547, MOLDED GLASS FIBER PIPE INSULATION, OPERATING TEMPERATURE RANGE: 0 TO 850 DEG F, VAPOR BARRIER JACKET: ASTM C1136, TYPE I, FACTORY APPLIED REINFORCED FOIL DRAFT WITH

SELF SEALING ADHESIVE JOINTS.

P-5 ASTM C534, TYPE I, FLEXILE, CLOSED CELL ELASTOMERIC INSULATION, TUBULAR, OPERATING

TEMPERATURE RANGE: MINUS 70 TO 180 DEG F.

1. PROVIDE TEMPERATURE AND PRESSURE RELIEF VALVE.

2. PROVIDE SECONDARY DRAIN PAN.

ELECTRIC WATER HEATER SCHEDULE

ID MANUFACTURER MODEL CAPACITY

(GAL)

FIRST HOUR

RATING (GAL)

SIZE (DIAxH)

(IN.)

RECOVERY @

90°F RISE

(GAL)

WATER CONN.

(IN)

ELECTRICAL

VOLTS PHASE WATTS

EWH-1 BRADFORD WHITE RE130L6 28 42 20x30 21 3/4" 240 1 4500

R

EV

IE

W

/2

0/

R

EV

IE

W

/2 2/

BI

D

SE

T

/5

/2

T

T

T

M

GARAGE

FIRE

CACHE

FIRE

OFFICE

TOILET

RH-2

RH-1

RH-1

RH-3

RH-3

EG-1

70 CFM

SR-1

90 CFM

SR-1

25 CFM

DF-1

DF-1

DF-1DF-1

6"ø

6"ø

6"ø

EBB-3

EBB-2

EBB-1

3/4"ø

3/4"ø

3/ 4" ø

3/4"ø

1¼" G TO METER

4" EA. TERMINATE PER MANUFACTURER'S

REQUIREMENTS (TYP)

6" SA UP

6" SA UP

6" EA UP

TO RADIANT HEATERS

MOUNT @ 14' AFF TO

CENTER

MOTORIZED

DAMPER

CO/NO2

IL-1

M

1 1/4"ø

1/

4" ø

G

G

3/ 4" ø

3/4"ø

'-0

" M

IN

EDH-1

ERV-1

6" EA DN

6" SA DN

6" SA DN

6" EA

8" OA

MOUNT @ 14'-0" AFF TO CENTER

EF-1

1 DESTRATIFICATION FAN CONTROLLER.

KEYNOTES

2 CO/NO2 SENSOR MOUNTED AT MANUFACTURERS

RECOMMENDATIONS. SENSOR SHALL BE BRASCH GSE2-NCM-24.

PROVIDE RELAYS FOR EXHAUST FAN AND LOUVER FOR INTERLOCK.

SEE WIRING DIAGRAM ON ELECTRICAL DRAWINGS. (APPLIES TO BASE

BID AND ALTERNATE)

*NOTE: SEQUENCE APPLIES TO BASE BID AND ALTERNATE BID

EXHAUST FAN:

EXHAUST FAN SHALL BE SUPPLIED WITH LOCAL HAND/OFF/AUTO (HOA) SWITCH

WITH RED INDICATOR LIGHT. INDICATOR LIGHT SHALL BE ENERGIZED

WHENEVER FAN IS IN OPERATION.

- IN "HAND" MODE, MOTORIZED DAMPER ON INTAKE LOUVER SHALL FULLY

OPEN AND CONNECTED EXHAUST FAN SHALL BE ENERGIZED AND SHALL

REMAIN ENERGIZED UNTIL MANUALLY SHUT OFF.

- IN "AUTO" MODE, MOTORIZED DAMPER ON INTAKE LOUVER AND FAN SHALL

OPERATE PER NO/CO2 SEQUENCE AS INDICATED BELOW.

- IN "OFF" MODE, MOTORIZED DAMPER SHALL FULLY CLOSE AND EXHAUST FAN

SHALL BE DE-ENERGIZED. THIS MODE SHALL BE USED FOR MAINTENANCE AND

INSPECTION PURPOSES ONLY.

CO/NO2 OPERATION:

CARBON MONOXIDE (CO) AND NITROGEN DIOXIDE (NO2) DETECTORS SHALL

PREVENT MAXIMUM CO LEVEL OF 25 PPM AND NO2 LEVEL OF 3 PPM PER

MCC-2015 SECTION 404.1. UPON DETECTION OF USER-ADJUSTABLE NO/CO2

LEVELS, MOTORIZED DAMPER ON INTAKE LOUVER SHALL FULLY OPEN AND

CONNECTED EXHAUST FAN SHALL BE ENERGIZED. SYSTEM SHALL OPERATE

FOR A MINIMUM OF 30 MINUTES AND UNTIL CONCENTRATION LEVELS OF

NO/CO2 HAVE DROPPED BELOW SET LEVELS.

SEQUENCE OF OPERATIONS: (EXHAUST FAN AND LOUVER)

ERV-1

EDH-1

6" ø

6" ø

6" ø

6"ø

EA

SA

SA

EA

8"ø

6"ø8"ø

*APPLIES TO BASE BID AND ALTERNATE BID

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

© U.P. Engineers & Architects, Inc.

PR

OJ

EC

T N

O:

DR

AW

N

BY

CH

EC

KE

D:

AP

PR

OV

ED

DE

SI

GN

ED

B Y:

w w w .u pe a.

co m

IS

SU

ED

F O R

D A

TE

P:

\M

-0

D

TM

B- M an is tiq ue

F ire

S ho p G ar ag e\ D w gs

\M ec ha ni ca l\M

-0

-D

TM

B- M

AN

IS

TI

Q

U E-

FI

R

E-

SH

O P_

M ec ha ni ca l.r vt

/5

/2

8:

:2

AM

M101

MECHANICAL PLAN

- BASE BID

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

MI

CH

IG

AN

D

EP

T.

OF

N

AT

UR

AL

R

ES

OU

RC

ES

MA

NI

ST

IQ

UE

, M I 4

M

-0

SP JG JGSP

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

M

IC

H

IG

A N D

EP

T.

O F N A

TU

R A L R

ES

O U R C

ES

1/8" = 1'-0"A4 MECHANICAL PLAN

1/8" = 1'-0"A2 PLATFORM MECHANICAL PLAN

ELECTRIC BASEBOARD HEATER SCHEDULE

ID DESCRIPTION MANUFACTURER MODEL WATTS CONTROL

VOLTAGE

LENGTH

(FT) VOLTAGE PHASE AMPS

EBB-1 SURFACE MOUNT QMARK 2545NW 940 24V 5 208 1 4.5

EBB-2 SURFACE MOUNT QMARK 2543NW 564 24V 3 208 1 2.7

EBB-3 SURFACE MOUNT QMARK 2545NW 940 24V 5 208 1 4.5

1. PROVIDE WITH TRANSFORMER, CONTACTOR, AND WIRING.

2. PROVIDE WITH 7-DAY PROGRAMMABLE THERMOSTAT AND WIRING.

3. INSTALL PER MANUFACTURER'S REQUIREMENTS. MAINTAIN ALL RECOMMENDED CLEARANCES.

4. COORDINATE INSTALLATION WITH ELECTRICAL CONTRACTOR.

B2 ERV ISOMETRIC

N N

R

EV

IE

W

/2

0/

R

EV

IE

W

/2 2/

BI

D

SE

T

/5

/2

T

M

GARAGE

SF

FIRE

CACHE

FIRE

OFFICE

TOILET

EG-1

70 CFM

SR-1

90 CFM

SR-1

25 CFM

DF-1

DF-1

DF-1DF-1

6"ø

6"ø

6"ø

RH-3

RH-3

BOILER ZONES

ZONE 1: GARAGE

ZONE 2: TOILET, FIRE OFFICE, FIRE CACHE

BOILER PIPING UP TO

MANIFOLDS (TYP)

TO RADIANT HEATERS

M

1¼" G TO METER

G

G

3/ 4" ø

3/ 4" ø1 1/4"ø

TO BOILER

ZONE 2

TO BOILER ZONE 1

4" EA. TERMINATE PER MANUFACTURER'S

REQUIREMENTS (TYP)

SEE MEZZANINE PLAN

FOR CONTINUATION

MOUNT @ 14' AFF TO

CENTER

MOTORIZED

DAMPER

CO/NO2

IL-1

2 (REFERENCE

KEYNOTE 2 ON

SHEET M101)

1"ø

'-0

" M

IN

EDH-1

ERV-1

6" EA DN

6" SA DN

6" SA DN

6" EA

8" OA

B-1

3" CA AND EA. PROVIDE

CONCENTRIC TERMINATION PER

MANUFACTURER'S REQUIREMENTS

HEATING MANIFOLDS

1 1/4"ø

1¼" G DN TO BOILER

SEE MECHANICAL PLAN

FOR CONTINUATION

G

P-3 P-1 P-2

EF-1

MOUNT @ 14'-0" AFF TO

CENTER

BOILER B-1

(SEE SCHEDULE)

AIR VENT

PRESSURE RELIEF VALVE

UNION

P/T GAUGE

DRAIN VALVE

�12" MAX

REDUCED PRESSURE

BACKFLOW PREVENTER

PRESSURE GAUGE

PRESSURE REDUCING VALVE

CW

Y-STRAINER

CHECK VALVE (TYP)

PUMP P-3

SHUT-OFF VALVE (TYP)

PUMP P-1 PUMP P-2

HEATING MANIFOLD (TYP)

CIRCUIT SETTER (TYP)

7" THERMOMETER

EXPANSION TANK: "TACO"

PAX10-150 OR EQUAL

SPIROVENT VJS150

OR EQUAL

2" 2"

2"

2"

1½"

1½"

¾"

¾"

CONCRETE SLAB

PLASTIC STAPLE

RIDGID

INSULATION

BASE MATERIAL TUBING

WIRE MESH, REBAR OR STAPLE

TO RIGID FOAM

EDGE INSULATION

VALVELESS MANIFOLD

TRIPLE DUTY VALVE

END CAP W/ GASKET

TUBING

(SUPPLY)

VALVELESS MANIFOLD

MANIFOLD ADAPTER

HOT WATER RETURN

TO BOILER OR

WATER HEATER

HOT WATER SUPPLY

FROM BOILER OR

WATER HEATER

TUBING

(RETURN)

COMPRESSION FITTINGS

END CAP W/ GASKET

COMPRESSION FITTINGS

MANIFOLD ADAPTER

VALVED MANIFOLD (SUPPLY)

THERMAL ACTUATOR

MOTORIZED VALVE ACTUATOR

1 PROVIDE BOILER E-STOP PER CSD-1 REQUIREMENTS. PROVIDE ENGRAVED PLAQUE ABOVE PUSH

BUTTON LABELED "BOILER E-STOP".

KEYNOTES

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

© U.P. Engineers & Architects, Inc.

PR

OJ

EC

T N

O:

DR

AW

N

BY

CH

EC

KE

D:

AP

PR

OV

ED

DE

SI

GN

ED

B Y:

w w w .u pe a.

co m

IS

SU

ED

F O R

D A

TE

P:

\M

-0

D

TM

B- M an is tiq ue

F ire

S ho p G ar ag e\ D w gs

\M ec ha ni ca l\M

-0

-D

TM

B- M

AN

IS

TI

Q

U E-

FI

R

E-

SH

O P_

M ec ha ni ca l.r vt

/5

/2

8:

:3

AM

M201

MECHANICAL PLAN

- ALTERNATE #1

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

MI

CH

IG

AN

D

EP

T.

OF

N

AT

UR

AL

R

ES

OU

RC

ES

MA

NI

ST

IQ

UE

, M I 4

M

-0

SP JG JGSP

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

M

IC

H

IG

A N D

EP

T.

O F N A

TU

R A L R

ES

O U R C

ES

1/8" = 1'-0"A4 MECHANICAL PLAN - ALTERNATE #1

1/8" = 1'-0"A2 PLATFORM MECHANICAL PLAN - ALTERNATE #1

NOTES:

PROVIDE WITH CONDENSATE NEUTRALIZER KIT, BOILER CIRCULATOR, LOW WATER CUT-OFF SWITCH WITH MANUAL RESET, CONCENTRIC VENT KIT, BOILER

CIRCULATOR, AND GAS REGULATOR.

PROVIDE PRIMARY/SECONDARY PIPING PER DETAIL.

COORDINATE ELECTRICAL REQUIREMENTS WITH ELECTRICAL CONTRACTOR.

PROVIDE WITH OUTDOOR RESET CONTROL.

BOILER SCHEDULE

ID MANUFACTURER MODEL

NUMBER

MAX INPUT

CAPACITY

(MBH)

MIN INPUT

CAPACITY

(MBH)

OUTPUT

CAPACITY

(MBH)

WATER

CONNECT.

(IN.)

GAS

CONNECT.

(IN)

VENT

(IN.)

COMB.

AIR (IN)

EWT(°F) LWT(°F) APPROX.

WEIGHT W/

WATER (LBS)

ELECTRICAL

VOLTS PHASE

B-1 LOCHINVAR WHB285N 285 28.5 264 1-1/4" 1/2" 3 3 111.4 91.4 225 120 1

HEATING PIPE INSULATION SCHEDULE

SYSTEM TYPE INSUL. TYPE PIPE SIZES INSULATION

THICKNESS

LOW TEMPERATURE HEATING WATER

SUPPLY AND RETURN (40 TO 105

DEGREES F)

P-1 ALL SIZES 1"

MED TEMPERATURE HEATING WATER

SUPPLY AND RETURN (105 TO 140

DEGREES F)

P-1 1-1/4" AND SMALLER

1-1/2" AND LARGER

1" 1-1/2"

HIGH TEMPERATURE HEATING WATER

SUPPLY AND RETURN (141 TO 200

DEGREES F)

P-1 1-1/4" AND SMALLER

1-1/2" AND LARGER

1-1/2" 2"

PIPING INSULATION SCHEDULE

INSULATION

TYPE

DESCRIPTION

P-1 ASTM C547, MOLDED GLASS FIBER PIPE INSULATION, OPERATING TEMPERATURE RANGE: 0 TO 850 DEG F, VAPOR BARRIER JACKET: ASTM C1136, TYPE I, FACTORY APPLIED REINFORCED FOIL DRAFT WITH

SELF SEALING ADHESIVE JOINTS.

P-5 ASTM C534, TYPE I, FLEXILE, CLOSED CELL ELASTOMERIC INSULATION, TUBULAR, OPERATING

TEMPERATURE RANGE: MINUS 70 TO 180 DEG F.

INFLOOR RADIANT HEATING SCHEDULE

AREA SERVED HEATED AREA(SQ. FT.)

TOTAL

RADIANT

LOAD (BTU)

TOTAL

RADIANT

LOAD (BTUH/

SQ. FT.)

GPM HEAD LOSS

(FT.)

WATER

SUPPLY TEMP

@ -20°F

OUTDOOR

SUPPLY

WATER

TEMP

DROP (°F)

S/R TUBE

LENGTH

(FT. ONE

WAY)

S/R TUBE

(TYPE-SIZE)

AVG. LOOP

LENGTH (FT)

LOOP TUBE

(TYPE-SIZE)

# OF

CIRCUITS

GARAGE 4085 170441 41.7 20 25 111.4 20 15 1-1/2"-COPPER 300 1/2" RADIANTPEX+ 15

OFFICE,

TOILET,

CACHE

362 13147 36.3 0.7 12.6 111.4 20 15 3/4"-COPPER 180 1/2" RADIANTPEX+ 2

NOTES:

1. DESIGN BASED ON "WATTS RADIANTPRO". INSTALL PER MANUFACTURER'S REQUIREMENTS.

2. OUTDOOR DESIGN CONDITIONS OF -20 DEGREES f @ 20 MPH WIND.

3, UNDERSLAB INSULATION SHALL BE R-10 MINIMUM. EDGE INSULATION SHALL BE R-15 MINIMUM.

NOT TO SCALEB1 BOILER PIPING DETAIL

PUMP SCHEDULE

ID DESCRIPTION MANUFACTURER MODEL

NUMBER

FLOW HEAD

(FT)

SUCTION SIZE DISCHARGE SIZE ELECTRICAL NOTES

VOLTS PHASE HP AMPS

P-1 ZONE PUMP TACO 1915 20.0 GPM 24.3 1 1/2" 1 1/2" 208 1 1 8.8 1,2

P-2 ZONE PUMP TACO 0014 0.7 GPM 12.6 3/4" 3/4" 120 1 1/8 1.45 1,2

P-3 BOILER CIRC PUMP TACO 0013 27.0 GPM 5 1 1/2" 1 1/2" 120 1 1/6 2.0 1,2

1. PROVIDE CONTROL SYSTEM TO INTERLOCK WITH CORRESPONDING BOILER.

2. COORDINATE ELECTRICAL REQUIREMENTS WITH ELECTRICAL CONTRACTOR.

12" = 1'-0"A1 INFLOOR HEATING

NOT TO SCALEB2 HYDRONIC MANIFOLD DETAIL

N N

R

EV

IE

W

/2

0/

R

EV

IE

W

/2 2/

BI

D

SE

T

/5

/2

EXHAUST OR

SUPPLY DUCT

TAPERED TAKEOFF INSIDE PAINTED FLAT

BLACK

GALVANIZED SHEET

METAL HOUSING

CEILING

MOUNTING FLANGE

PER CEILING TYPEGRILLE WITH OPPOSED

BLADE DAMPER

(SEE SCHEDULE)

FASTEN SECURELY TO STRUCTURE

ABOVE PER MANUFACTURER'S

RECCOMENDATIONS. 4" SINGLE WALL PIPE

GAS SUPPLY

GAS

MAINEXTERIOR

WALL

STAINLESS STEEL

FLEX CONNECTOR

REFLECTOR

BURNER

ASSEMBLY

WALL FLANGE ASSEMBLY

VENT ADAPTOR

VENT TERMINAL

EXTERIOR

WALL

SEAL ALL WALL

PENETRATIONS

PER MANUFACTURER'S REQUIREMENTS

COLLAR3" MAX

" M

IN

COMBUSTION AIR OPENING

INSULATION

DUCT

OUTSIDE END BEARING

DAMPER BLADE

1/8" CLEARANCE ALL AROUND

1/2" ROUND ROD PIN

INSULATION STANDOFF

HANDLE WITH

LOCKING QUADRANT

INSIDE END BEARING

INSULATION STIFFEN BLADE AS REQUIRED

DAMPER BLADE

HANDLE WITH LOCKING QUADRANT

DUCT

SECTION

SIDE ELEVATION

NOTES:

1. DELETE INSULATION STAND-OFF FOR DUCTWORK WITHOUT EXTERIOR INSULATION.

2. DETAIL SIMILAR FOR ROUND AND MULTI-BLADE DAMPERS.MESH INSECT SCREEN

SILICONE CAULK AT WALL PENETRATION

GRAVITY BACKDRAFT DAMPER ON

EXHAUST

DUCTWORK

(SEE PLAN FOR SIZE) PAINTED ALUMINUM WALL CAP

(COLOR SELECTED BY OWNER)

FAN GUARD

MOTOR

FASTEN SECURELY TO WALL

CAULK PERIMETER

GRAVITY BACKDRAFT

DAMPER

WEATHER SHIELD

WITH BIRD SCREEN

NOTES:

1.

2.

PROVIDE STANDARD RADIUS ELBOWS WHEN POSSIBLE - USE MITERED ELBOWS WHERE REQUIRED.

ALL MITERED ELBOWS SHALL HAVE VANES. VANES SHALL BE CONSTRUCTED, SUPPORTED & FASTENED AS

RECOMMENDED BY SMACNA

VD

VD

SPLITTER

RECTANGULAR SUPPLY TEE RECTANGULAR

DUCT SUPPLY

BRANCH TAKE-OFF

RECTANGULAR

DUCT SUPPLY

BRANCH TAKE-OFF

TRANSITION PIECE STANDARD

RADIUS ELBOW

MITERED ELBOW

WITH VANE(S)

ROUND TO

RECTANGULAR

RECTANGULAR

DUCT SUPPLY

BRANCH TAKE-OFF

RECTANGULAR SUPPLY TEERECTANGULAR TO ROUND

VD

30° MAX.

'R' SHALL EQUAL

TO OR GREATER

THAN 'W'.

'R'

'W'

15° MAX.VD

SPLITTER

15°

MAX.

'W'

PARALLEL BLADE

DAMPER

LOW VOLTAGE DAMPER

ACTUATOR MOUNTED ON

EXTERIOR OF DUCT

(PROVIDE INSULATION

STANDOFF)

SEAL JOINTS WITH SILICONE

CAULK PERIMETER

VERIFY WALL CONSTRUCTION

O

PE

N

IN

G S

IZ

E

(F

IE

LD

V

ER

IF

Y)

DRAINABLE FIXED BLADE LOUVER

(SEE SCHEDULE)

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

© U.P. Engineers & Architects, Inc.

PR

OJ

EC

T N

O:

DR

AW

N

BY

CH

EC

KE

D:

AP

PR

OV

ED

DE

SI

GN

ED

B Y:

w w w .u pe a.

co m

IS

SU

ED

F O R

D A

TE

P:

\M

-0

D

TM

B- M an is tiq ue

F ire

S ho p G ar ag e\ D w gs

\M ec ha ni ca l\M

-0

-D

TM

B- M

AN

IS

TI

Q

U E-

FI

R

E-

SH

O P_

M ec ha ni ca l.r vt

/5

/2

8:

:3

AM

M501

MECHANICAL

DETAILS

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

MI

CH

IG

AN

D

EP

T.

OF

N

AT

UR

AL

R

ES

OU

RC

ES

MA

NI

ST

IQ

UE

, M I 4

M

-0

SP JG JGSP

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

M

IC

H

IG

A N D

EP

T.

O F N A

TU

R A L R

ES

O U R C

ES

NOT TO SCALEC4 EXHAUST GRILLE DETAIL

NOT TO SCALEA3 INFRARED RADIANT HEATER DETAIL

NOT TO SCALEB4 VOLUME DAMPER DETAIL

NOT TO SCALEB2 WALL CAP DETAIL

NOT TO SCALEA2 WALL EXHAUST FAN DETAIL

NOT TO SCALEC2 TYPICAL DUCT FITTINGS

NOT TO SCALEB1 DUCTED WALL LOUVER DETAIL

R

EV

IE

W

/2

0/

R

EV

IE

W

/2 2/

BI

D

SE

T

/5

/2

1 2 3 4 5

1 2 3 4 5

D

C

B

A

D

C

B

A

© U.P. Engineers & Architects, Inc.

PR

OJ

EC

T N

O:

DR

AW

N

BY

CH

EC

KE

D:

AP

PR

OV

ED

DE

SI

GN

ED

B Y:

w w w .u pe a.

co m

IS

SU

ED

F O R

D A

TE

P:

\M

-0

D

TM

B- M an is tiq ue

F ire

S ho p G ar ag e\ D w gs

\M ec ha ni ca l\M

-0

-D

TM

B- M

AN

IS

TI

Q

U E-

FI

R

E-

SH

O P_

M ec ha ni ca l.r vt

/5

/2

8:

:4

AM

M601

MECHANICAL

SCHEDULES

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

MI

CH

IG

AN

D

EP

T.

OF

N

AT

UR

AL

R

ES

OU

RC

ES

MA

NI

ST

IQ

UE

, M I 4

M

-0

SP JG JGSP

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

M

IC

H

IG

A N D

EP

T.

O F N A

TU

R A L R

ES

O U R C

ES

VENTILATION CALCULATION AND CODE REQUIREMENTS PER MICHIGAN MECHANICAL CODE

ROOM

NUMBER ROOM NAME OCCUPANCY CLASSIFICATION

FLOOR AREA

(SQ FT) AIR DISTRIBUTION CONFIGURATION

OCCUPANCY

DENSITY,

PEOPLE /1000

FT2

ZONE

POPULATION, #

OF PEOPLE IN

THE SPACE

PEOPLE OUTDOOR

AIR RATE,

CFM/PERSON

AREA

OUTDOOR AIR

RATE, CFM/FT2

PEOPLE

OUTDOOR AIR

RATE (CFM)

AREA

OUTDOOR AIR

RATE (CFM)

OUTDOOR

AIRFLOW TO

THE ZONE

(CFM)

ZONE AIR

DISTRIBUTION

EFFECTIVENESS

ZONE

OUTDOOR

AIRFLOW

(CFM)

EXHAUST

AIRFLOW

RATE FROM

THE ROOM

(CFM)

101 GARAGE Parking Garage (Enclosed) 4018 CEILING SUPPLY OF WARM AIR AND CEILING RETURN 0 0 0.0 0.00 0 0 0 0.8 0 3014 102 TOILET Toilet Rooms - public (intermittent) 56 CEILING SUPPLY OF WARM AIR AND CEILING RETURN 0 0 0.0 0.00 0 0 0 0.8 0 50 103 FIRE OFFICE Office space 97 CEILING SUPPLY OF WARM AIR AND CEILING RETURN 5 1 5.0 0.06 5 6 11 0.8 14 104 FIRE CACHE Storage Rooms (unoccupied) 194 CEILING OR FLOOR SUPPLY OFWARM AIR AND FLOOR RETURN 0 0 0.0 0.00 0 0 0 1 0

Grand total 14 3064

DIFFUSER, GRILLE, REGISTER SCHEDULE

ID DESCRIPTION MANUFACTURER MODEL

NUMBER

MOUNTING

FRAME

NECK SIZE

(IN)

MODULE SIZE

(IN)

THROW COLOR MATERIAL Notes

EG-1 CEILING EXHAUST GRILLE NAILOR 51EC SURFACE 6 x 6 10 X 6 - WHITE ALUMINUM 1,2,4 SR-1 SIDEWALL SUPPLY REGISTER NAILOR 61SH-O SURFACE 8 X 4 10 X 6 - WHITE STEEL 1,2,3,5

1. BORDER TYPE SHALL BE COMPATIBLE WITH ARCHITECTURAL CEILING TYPE IN WHICH THE DEVICE IS LOCATED.

2. SEE PLAN FOR LOCATIONS AND QUANTITIES OF AIR DEVICES.

3. 3/4" BLADE SPACING. BLADES PARALLEL TO LONG DIMENSION.

4. 1/2"x1/2"x1/2" EGGCRATE GRID.

5. PROVIDE WITH OPPOSED BLADE DAMPER ADJUSTABLE FROM FACE.

DUCTWORK INSULATION SCHEDULE

SYSTEM TYPE INSULATION

TYPE

INSULATION OR

LINER

THICKNESS

SUPPLY DUCTS (EXTERNALLY INSULATED D-1, D-2, D-6 1-1/2"

EXHAUST DUCTS WITHIN 10 FEET OF EXTERIOR

OPENINGS D-1, D-2 1"

DUCTWORK INSULATION TYPE SCHEDULE

INSULATION

TYPE

DESCRIPTION

D-1

ASTM C1290, TYPE III, FLEXIBLE GLASS FIBER, COMMERCIAL GRADE WITH FACTORY

APPLIED REINFORCED FOIL JACKET MEETING ASTM C1136, TYPE II, MAX. OPERATING

TEMPERATURE: 250 DEG. F, DENSITY: 1.5 LBS/CU FT.

D-2 ASTM C612, TYPE IA OR IB, RIGID GLASS FIBER, WITH FACTORY APPLIED ALL SERVICE

FACING MEETING ASTM C1136, TYPE II, DENSITY: 6.0 LBS/CU FT.

D-6 ASTM C534, TYPE II, FLEXIBLE, CLOSED CELL ELASTOMERIC INSULATION, SHEET,

SERVICE TEMPERATURE RANGE: MINUS 58 TO 180 DEG F.

LOUVER SCHEDULE

ID DESCRIPTION MANUFACTURER MODEL MATERIAL DIMENSIONS

(WxH) (IN)

THICKNESS

(IN) CFM

PRESSURE

DROP

(IN. WG.)

FREE AREA

(SQ. FT.)

VELOCITY

(FT/MIN)

IL-1 INTAKE LOUVER GREENHECK ESD-603 ALUMINUM 40x43 6 3100 0.04 6.1 500

1. PROVIDE WITH BIRDSCREEN AND MOTORIZED DAMPER PER DETAILS.

FAN SCHEDULE

ID DESCRIPTION MANUFACTURER MODEL NUMBER AIR FLOW

(CFM)

EXT. SP. (FT) RPM WALL

OPENING (IN)

ELECTRICAL Notes

VOLTS PHASE HP WATTS AMPS

DF-1 DESTRATIFICATION FAN AIRIUS A-25-SP-STD-120-W VARIABLE - 1650 - 120 1 - 35 0.32 5,6 EF-1 SIDEWALL EXHAUST FAN GREENHECK SBE-1H24-4 3100 0.1 710 33.75 x 33.75 120 1 1/4 - 5.8 1,2,3,4,5

1. PROVIDE WITH GRAVITY DAMPER WD-320-PB-26x26.

2. PROVIDE WITH LONG WALL HOUSING, FLUSH EXTERIOR, W/ OSHA GUARD.

3. PROVIDE WITH WEATHERHOOD AND BIRDSCREEN.

4. MOTOR ACCESS FROM INTERIOR OF BUILDING.

5. COORDINATE ELECTRICAL REQUIREMENTS WITH ELECTRICAL CONTRACTOR.

6. PROVIDE WITH FACTORY WALL-MOUNT SPPED CONTROLLER #TRIAC-120-5. PROVIDE CABLE SUPPORT PER MANUFACTURER'S

RECOMMENDATIONS.

ENERGY RECOVERY VENTILATOR SHEDULE

ID MANUFACTURER MODEL NUMBER EXHAUST

AIR (CFM)

OUTDOOR

AIR (CFM)

WINTER SUMMER WEIGHT

(LBS)

VOLTS PHASE HP MCA MOCP NOTES

EADB (°F) EAWB (°F) LADB

(°F)

EFFEC

T.

EADB

(°F)

EAWB (°F) LADB (°F) EFFEC

T.

ERV-1 RENEWAIRE EV PREMIUM L 70 115 -20 -21 32.5 94.3 77.4 64.9 76 81 52 120 1 2@0.11 10 10 1,2,3

1. PROVIDE VIBRATION ISOLATION PER MANUFACTURER'S RECOMMENDATIONS.

2. PROVIDE DIGITAL TIMECLOCK CONTROL AND ALL REQUIRED COMPONENTS AND WIRING.

3. COORDINATE ELECTRICAL REQUIREMENTS WITH ELECTRICAL CONTRACTOR.

1. PROVIDE WITH DISCONNECT SWITCH, AIRFLOW SWITCH, PRIMARY/SECONDARY OVER TEMP PROTECTION AND GROUNDING LUG.

2. PROVIDE WITH DUCT MOUNTED THERMOSTAT WITH SENSOR.

3. INTERLOCK WITH ASSOCIATED ENERGY RECOVERY UNIT. PROVIDE REQUIRED CONTROL COMPONENTS AND WIRING.

ELECTRIC DUCT HEATER SCHEDULE

ID DESCRIPTION MANUFACTURER MODELNUMBER

AIRFLOW

(CFM) KW CONTROL

VOLTAGE

DIMENSIONS

(IN) VOLTS PHASE STAGE

EDH-1 OPEN COIL RENEWAIRE RDH3208-8 115 3 24 8"Ø 208 1 1

ELECTRIC BASEBOARD HEATER SCHEDULE

ID DESCRIPTION MANUFACTURER MODEL WATTS CONTROL

VOLTAGE

LENGTH

(FT) VOLTAGE PHASE AMPS

EBB-1 SURFACE MOUNT QMARK 2545NW 940 24V 5 208 1 4.5

EBB-2 SURFACE MOUNT QMARK 2543NW 564 24V 3 208 1 2.7

EBB-3 SURFACE MOUNT QMARK 2545NW 940 24V 5 208 1 4.5

1. PROVIDE WITH TRANSFORMER, CONTACTOR, AND WIRING.

2. PROVIDE WITH 7-DAY PROGRAMMABLE THERMOSTAT AND WIRING.

3. INSTALL PER MANUFACTURER'S REQUIREMENTS. MAINTAIN ALL RECOMMENDED CLEARANCES.

4. COORDINATE INSTALLATION WITH ELECTRICAL CONTRACTOR.

GAS FIRED RADIANT HEATER SCHEDULE

ID MANUFACTURER MODELNUMBER

CAPACITY

(MBH)

LENGTH

(FT)

TURBULATOR

LENGTH (FT)

GAS CONN.

SIZE (IN.)

VENT

(IN) VOLTS PHASE WATTS

RH-1 SCHWANK STS-JZ-80-20 80 21'-4" 14' 1/2" 4" 120 1 145

RH-2 SCHWANK STS-JZ-80-40 80 31'-0" 8' 1/2" 4" 120 1 145

RH-3 SCHWANK STS-JZ-80-40 80 40'-8" 12' 1/2" 4" 120 1 145

NOTES:

1. INSTALL PER MANUFACTURER'S RECOMMENDATIONS.

2. PROVIDE WITH 7-DAY PROGRAMMABLE THERMOSTAT. COORDINATE WITH CONTROLS CONTRACTOR.

3. COORDINATE ELECTRICAL REQUIREMENTS WITH ELECTRICAL CONTRACTOR.

4. PROVIDE COMBUSTION AIR PER MANUFACTURER'S REQUIREMENTS AND CURRENT CODE. TERMINATE PER MANUFACTURER'S REQUIREMENTS.

INDOOR COMBUSTION AIR CALCULATION

ROOM TOTAL BTU'S

IN ROOM

VOLUME OF

ROOM

TOTAL CU. FT.

NEEDED AT 50 CU. FT.

PER 1,000 BTUH (PER

IFGC 304.5.1)

ADDITIONAL

CU. FT.

NEEDED

GARAGE 400000 64287.36 CF 3214.37 CF NO

R

EV

IE

W

/2

0/

R

EV

IE

W

/2 2/

BI

D

SE

T

/5

/2

C

B

A

PR

OJ

EC

T N

O:

DR

AW

N

BY

CH

EC

KE

D:

AP

PR

OV

ED

DE

SI

GN

ED

B Y:

IS

SU

ED

F O R

D A

TE

al \M

-0

-D

TM

B- M

AN

IS

TI

Q

U E-

FI

R

E-

SH

O P_

M ec ha ni ca l.r vt

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

MI

CH

IG

AN

D

EP

T.

OF

N

AT

UR

AL

R

ES

OU

RC

ES

MA

NI

ST

IQ

UE

, M I 4

M

-0

SP JG JGSP

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

M

IC

H

IG

A N D

EP

T.

O F N A

TU

R A L R

ES

O U R C

ES

R

EV

IE

W

/2

0/

R

EV

IE

W

/2 2/

BI

D

SE

T

/5

/2

A

PR

OJ

EC

T N

O:

DR

AW

N

BY

CH

EC

KE

D:

AP

PR

OV

ED

DE

SI

GN

ED

B Y:

IS

SU

ED

F O R

D A

TE

al \M

-0

-D

TM

B- M

AN

IS

TI

Q

U E-

FI

R

E-

SH

O P_

M ec ha ni ca l.r vt

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

MI

CH

IG

AN

D

EP

T.

OF

N

AT

UR

AL

R

ES

OU

RC

ES

MA

NI

ST

IQ

UE

, M I 4

M

-0

SP JG JGSP

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

M

IC

H

IG

A N D

EP

T.

O F N A

TU

R A L R

ES

O U R C

ES

R

EV

IE

W

/2

0/

R

EV

IE

W

/2 2/

BI

D

SE

T

/5

/2

A

PR

OJ

EC

T N

O:

DR

AW

N

BY

CH

EC

KE

D:

AP

PR

OV

ED

DE

SI

GN

ED

B Y:

IS

SU

ED

F O R

D A

TE

al \M

-0

-D

TM

B- M

AN

IS

TI

Q

U E-

FI

R

E-

SH

O P_

M ec ha ni ca l.r vt

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

MI

CH

IG

AN

D

EP

T.

OF

N

AT

UR

AL

R

ES

OU

RC

ES

MA

NI

ST

IQ

UE

, M I 4

M

-0

SP JG JGSP

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

M

IC

H

IG

A N D

EP

T.

O F N A

TU

R A L R

ES

O U R C

ES

R

EV

IE

W

/2

0/

R

EV

IE

W

/2 2/

BI

D

SE

T

/5

/2

A

PR

OJ

EC

T N

O:

DR

AW

N

BY

CH

EC

KE

D:

AP

PR

OV

ED

DE

SI

GN

ED

B Y:

IS

SU

ED

F O R

D A

TE

al \M

-0

-D

TM

B- M

AN

IS

TI

Q

U E-

FI

R

E-

SH

O P_

M ec ha ni ca l.r vt

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

MI

CH

IG

AN

D

EP

T.

OF

N

AT

UR

AL

R

ES

OU

RC

ES

MA

NI

ST

IQ

UE

, M I 4

M

-0

SP JG JGSP

M A N

IS

TI

Q U E

FI

R E

SH

O P G A R A G E A T

W

YM

A N S

TA

TE

F O R

ES

T N U R

SE

R Y

M

IC

H

IG

A N D

EP

T.

O F N A

TU

R A L R

ES

O U R C

ES

R

EV

IE

W

/2

0/

R

EV

IE

W

/2 2/

BI

D

SE

T

/5

/2

File details come from the government source that posted it. Updated .