Addendum No. 2 FINAL.pdf
PDF 37 KB Posted
- Solicitation number
- RFQ - 171 - 230000000095
- Issued by
- Schoolcraft County, Mayville Village, Michigan
About this file
This document is Addendum No. 2 issued by UP Engineers & Architects, Inc. for the Manistique Fire Shop Garage at Wyman State Forest Nursery project in Manistique, Michigan. The addendum clarifies, modifies, and changes the original plans and specifications. It requires the installation of draftstopping in the attic to subdivide the space into areas no greater than 3,000 square feet, with access doors and maintaining attic ventilation.
The related state and local contract opportunity is for Project #751/22031.ABG, the Manistique Fire Shop Garage at Wyman State Forest Nursery. Bidders are instructed to email questions to Jeremy Gagnon at UP Engineers & Architects rather than submitting them online. Bid attachments must be uploaded to the SIGMA VSS system, and individual attachments cannot exceed 6 MB. If bidders experience SIGMA VSS issues, they are to notify the Office of Design and Construction and may be asked to email their proposals, which will be handled on a case-by-case basis.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Specifications 22031_Part2.pdf | ||
| Plans 22031_Part2.pdf | ||
| Specifications 22031_Part3.pdf | ||
| Plans 22031_Part1.pdf | ||
| Advertisment 22031.pdf | ||
| Specifications 22031_Part1.pdf | ||
| Addendum 1 22031.pdf | ||
| Plans 22031_Part3.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
707 Ashmun Street Sault Ste. Marie, MI 49783
906-635-0511 • 800-867-0511 • Fax: 906-635-0612
Offices also in:
Houghton
Iron Mountain Ishpeming Marinette
U.P. Engineers & Architects, Inc.
www.UPEA.com
[M12-02548]
ADDENDUM NO. 2
MANISTIQUE FIRE SHOP GARAGE
AT WYMAN STATE FOREST NURSERY
MANISTIQUE, MI
ADDENDUM NO. 2 is issued December 30, 2022, to clarify, modify, and/or change the original plans and specifications issued by UP Engineers and Architects. This ADDENDUM NO. 2 is hereby made part of the Contract Documents for the contract noted below.
File No. 751/22031.ABG, Manistique Fire Shop Garage at Wyman State Forest Nursery
Please acknowledge receipt of this ADDENDUM NO. 2 on the appropriate blank on the Bid Form and also include this addendum with the bid package.
PLANS
1. Provide draftstop in attic in line with truss to subdivide attic into not greater than 3,000 s.f. area. At draftstopping locations:
a. Draftstopping shall be 1/2” GWB or 1/2” Plywood.
b. Provide self-closing access door between attic areas, minimum construction:
1/2” Plywood panel, 22”x48”, with spring closer, hinges, latch, and gasket perimeter.
c. Ensure attic ventilation is maintained.
END OF ADDENDUM NO. 2
Prepared by:
U.P. Engineers & Architects, Inc
END OF ADDENDUM NO. 2