PLAN SET 20190501 FINAL.pdf
PDF 1 MB Posted
- Solicitation number
- BD-19-1206-40000-40000-36461
- Issued by
- Suffolk County, Massachusetts
About this file
This document is a plan set for the Massachusetts Bay Transportation Authority (MBTA) Fiber Optic Communication System (FOCS) Design. The project details the installation of a fiber optic communication network across multiple MBTA stations, including Braintree Station and Washington Village Station. The work includes furnishing and installing new fiber optic cable, network switches, data cabinets, patch panels, and other related equipment. The contractor will be responsible for verifying all distances and coordinating with the MBTA project engineer on the exact locations of the new equipment. The response due date and public opening for this contract opportunity is at the MBTA offices in Boston, Massachusetts.
The plan set provides detailed diagrams and equipment specifications for the fiber optic network, including the quantity and types of meters, switches, and other devices to be installed at each location. Pricing terms, funding sources, and incumbent information are not included in this document. This appears to be a technical design specification rather than a formal solicitation, so those commercial details would likely be found in the related state and local contract opportunity referenced.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MASSACHUSETTS BAY TRANSPORTATION AUTHORITY
FIBER OPTIC COMMUNICATION SYSTEM (FOCS) DESIGN
ISSUE FOR BID
633 17th Street, Suite 1500 Denver, Colorado 80202 633 17th Street, Suite 1500 Denver, Colorado 80202
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 2 OF 8
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 2 OF 8
FOCN-JA001
FIBER OPTIC CABLE BLOCK DIAGRAM
MASSACHUSETTS BAY TRANSPORTATION AUTHORITY
FIBER OPTIC COMMUNICATION SYSTEM (FOCS) DESIGN
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 2 OF 8
FOCN-JA001
FIBER OPTIC CABLE BLOCK DIAGRAM
COMMUNICATIONS4/28/19
DSE
MASSACHUSETTS BAY TRANSPORTATION AUTHORITY
FIBER OPTIC COMMUNICATION SYSTEM (FOCS) DESIGN
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 2 OF 8
FOCN-JA001
FIBER OPTIC CABLE BLOCK DIAGRAM
COMMUNICATIONS4/28/19
DSE
4th Floor
DATA CABINET
NO-EMI
45 HIGH STREET
DATA CONTROL CENTER
2nd
Floor
DATA CABINET
NON-EMI
BRAINTREE STATION
WASHINGTON VILLAGE STATION
10 PARK PLAZA 21 ARLINGTON AVE
WORKSTATION
WITH EMS
LICENSE
SIGNAL
INSTRUMENT
HOUSE
24 PORT INDUSTRIAL
SWITCH
24 PORT CAT 6
PATCH PANEL
WIDE AREA NETWORK
(EXISTING)
WIDE AREA NETWORK
(EXISTING)
WIDE AREA NETWORK
(EXISTING)
WIDE AREA NETWORK
(EXISTING)
FIBER DISTRIBUTION
PANEL 12 PORT SM-ST
FIBER DISTRIBUTION
PANEL 12 PORT SM-ST
48 PORT NETWORK
SWITCH NON-
RUGGEDIZED
ELECTRONIC
METERING SYSTEM /
APP / DB SYSTEM
FIBER DISTRIBUTION
PANEL 12 PORT SM-ST
UPS
OUTSIDE
DATA CABINET
(EXISTING)
NEW SOLID STATE METERS
(QUANTITY=4)
UPS
FIBER OPTIC CABLE
12f FO SM
12f FO SM
NEW SOLID STATE METERS
(QUANTITY=9)
FIBER DISTRIBUTION
PANEL 12 PORT SM-ST
(NEW)
24 PORT INDUSTRIAL
NETWORK SWITCH (NEW)
TRACTION POWER SUBSTATION
TRACTION POWER SUBSTATION
NEW DATA
CABINET
NEMA 4 - EMI
DATA CABINET
(EXISTING)
WORKSTATION
WITH EMS
LICENSE
24 PORT CAT 6
PATCH PANEL (NEW)
24 PORT INDUSTRIAL
NETWORK SWITCH (EXISTING)
FIBER DISTRIBUTION
PANEL (EXISTING)
ETHERNET
FIBER PATCH CABLES
FIBER OPTIC CABLE
EXISTING SYSTEMS
RESPONSIBILTY OF THE
CONTRACTOR
LEGEND
ETHERNET
FIBER PATCH CABLES
FIBER OPTIC CABLE
EXISTING SYSTEMS
RESPONSIBILTY OF THE
CONTRACTOR
LEGEND
FIBER DISTRIBUTION
PANEL (EXISTING)
FIBER DISTRIBUTION
PANEL (EXISTING)
633 17th Street, Suite 1500 Denver, Colorado 80202
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 3 OF 8
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 3 OF 8
FOCN-JA002
MASSACHUSETTS BAY TRANSPORTATION AUTHORITY
FIBER OPTIC COMMUNICATION SYSTEM (FOCS) DESIGN
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 3 OF 8
FOCN-JA002 COMMUNICATIONS4/29/19
DSE
FIBER OPTIC CABLE ROUTING BRAINTREE STATION
NOTE 1 TERMINATE ALL CAT 6 CABLING IN A RJ45 JUNCTION BOX
IN THE BASE OF THE POWER CABINET, CONNECT THE METER
WITH A CAT 6 SHIELDED PATCH CABLE.
NOTE2 FURNISH AND INSTALL 12F SM FO CABLE IN EXISTING
UNDERGROUND CONDUIT. CONTRACTOR TO VERIFY ALL
DISTANCES
ETHERNET
FIBER PATCH CABLES
FIBER OPTIC CABLE
EXISTING SYSTEMS
RESPONSIBILTY OF THE
CONTRACTOR
LEGEND
ETHERNET
FIBER PATCH CABLES
FIBER OPTIC CABLE
EXISTING SYSTEMS
RESPONSIBILTY OF THE
CONTRACTOR
LEGEND
BRAINTREE STATION
SIGNAL INSTRUMENT HOUSE
24 PORT INDUSTRIAL SWITCH (NEW)
24 PORT CAT 6
PATCH PANEL (NEW)
FIBER DISTRIBUTION PANEL 12 PORT SM-ST
(NEW)
OUTSIDE
DATA CABINET (EXISTING)
NEW SOLID STATE METERS (QUANTITY=4)
UPS (NEW)
FIBER OPTIC CABLE
12f FO SM (NEW)
TRACTION POWER SUBSTATION
NEW DATA CABINET
NEMA 4 - EMI
FIBER DISTRIBUTION PANEL (EXISTING)
WIDE AREA NETWORK
(EXISTING)
WIDE AREA NETWORK
(EXISTING)
633 17th Street, Suite 1500 Denver, Colorado 80202
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 4 OF 8
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 4 OF 8
FOCN-JA003
MASSACHUSETTS BAY TRANSPORTATION AUTHORITY
FIBER OPTIC COMMUNICATION SYSTEM (FOCS) DESIGN
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 4 OF 8
FOCN-JA003 COMMUNICATIONS4/28/19
DSE
MASSACHUSETTS BAY TRANSPORTATION AUTHORITY
FIBER OPTIC COMMUNICATION SYSTEM (FOCS) DESIGN
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 4 OF 8
FOCN-JA003 COMMUNICATIONS4/28/19
DSE
FIBER OPTIC CABLE ROUTING
WASHINGTON VILLAGE STATION
NOTE 1 TERMINATE ALL CAT 6 CABLING IN A RJ45 JUNCTION BOX
IN THE BASE OF THE POWER CABINET, CONNECT THE METER
WITH A CAT 6 SHIELDED PATCH CABLE.
NOTE 2 EXISITNG DATA CABINENT HAS EXISTING NETWORK
EQUIPMENT. COORDINATE WITH MBTA PROJECT ENGINEER FOR
THE EXACT LOCATION OF THE NEW EQUIPMENT.
ETHERNET
FIBER PATCH CABLES
FIBER OPTIC CABLE
EXISTING SYSTEMS
RESPONSIBILTY OF THE
CONTRACTOR
LEGEND
ETHERNET
FIBER PATCH CABLES
FIBER OPTIC CABLE
EXISTING SYSTEMS
RESPONSIBILTY OF THE
CONTRACTOR
LEGEND
WASHINGTON VILLAGE STATION
NEW SOLID STATE METERS (QUANTITY=9)
FIBER DISTRIBUTION
PANEL 12 PORT SM-ST
(NEW)
24 PORT INDUSTRIAL NETWORK SWITCH (NEW)
TRACTION POWER SUBSTATION
DATA CABINET (EXISTING)
24 PORT CAT 6
PATCH PANEL (NEW)
24 PORT INDUSTRIAL NETWORK SWITCH (EXISTING)
FIBER DISTRIBUTION PANEL (EXISTING)
WIDE AREA NETWORK
(EXISTING)
WIDE AREA NETWORK
(EXISTING)
633 17th Street, Suite 1500 Denver, Colorado 80202
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 5 OF 8
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 5 OF 8
FOCN-JA004
MASSACHUSETTS BAY TRANSPORTATION AUTHORITY
FIBER OPTIC COMMUNICATION SYSTEM (FOCS) DESIGN
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 5 OF 8
FOCN-JA004 COMMUNICATIONS4/28/19
DSE
MASSACHUSETTS BAY TRANSPORTATION AUTHORITY
FIBER OPTIC COMMUNICATION SYSTEM (FOCS) DESIGN
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 5 OF 8
FOCN-JA004 COMMUNICATIONS4/28/19
DSE
FIBER DISTRIBUTION EQUIPMENT AT TPSS
2 U SUMMIT EXTREME NETWORK SWITCH
24 PORT
1 U FIBER DISTRIBUTION PANEL
12 PORT CLOSED
1 U FIBER DISTRIBUTION PANEL
12 PORT OPEN
SINGLE MODE ST CONNECTORS
12F SINGLE MODE FIBER OPTIC CABLE
DIGITAL ELECTRIC POWER METERS
(QUANTITY VARIED)
NOTE 1 FIBER OPTIC PATCH CABLES HAVE ST CONNECTORS.
NOTE 2 FIBER OPTIC CABLE IS FUSION SPLICED USING ST PIGTAIL
CONNECTORS.
NOTE 3 24 PORT SWITCH IS SHOWN AS TYPICAL, 48 PORT
NETWORK SWITCH FOR DATA CENTER WILL HAVE SAME
CONNECTIVITY CONFIGURATION.
NOTE 1
NOTE 2
NOTE 3
633 17th Street, Suite 1500 Denver, Colorado 80202
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 6 OF 8
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 6 OF 8
FOCN-JA005
MASSACHUSETTS BAY TRANSPORTATION AUTHORITY
FIBER OPTIC COMMUNICATION SYSTEM (FOCS) DESIGN
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 6 OF 8
FOCN-JA005 COMMUNICATIONS4/28/19
DSE
MASSACHUSETTS BAY TRANSPORTATION AUTHORITY
FIBER OPTIC COMMUNICATION SYSTEM (FOCS) DESIGN
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 6 OF 8
FOCN-JA005 COMMUNICATIONS4/28/19
DSE
EQUIPMENT ENCLOSURE AT TPSS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
UL®
CAT.5e
LISTED
S M A R T P R O - U P S
Release Lock
TOP WITH EXHAUST FANS
42U NEMA 4 EMI RATED CABINET DOORS – FRONT AND REAR SIDES
CABLE MANAGEMENT
INDUSTRIAL NETWORK SWITCH
CAT 6 24 PORT PATCH PANEL
PULL OUT SHELF
POWER DISTRIBUTION UNIT
CABLE MANAGEMENT
FIBER DISTRIBUTION PANEL
POWER DISTRIBUTION UNIT
GROUND
NEW CABINENTS
GROUND
NEW CABINENTS
UNINTERRUPTIBLE POWER SUPPLY WITH
BATTERIES
633 17th Street, Suite 1500 Denver, Colorado 80202
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 7 OF 8
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 7 OF 8
FOCN-JA006
MASSACHUSETTS BAY TRANSPORTATION AUTHORITY
FIBER OPTIC COMMUNICATION SYSTEM (FOCS) DESIGN
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 7 OF 8
FOCN-JA006 COMMUNICATIONS4/28/19
DSE
MASSACHUSETTS BAY TRANSPORTATION AUTHORITY
FIBER OPTIC COMMUNICATION SYSTEM (FOCS) DESIGN
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 7 OF 8
FOCN-JA006 COMMUNICATIONS4/28/19
DSE
EQUIPMENT ENCLOSURE AT OCC
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
UL®
CAT.5e
LISTED
S M A R T P R O - U P S
TOP WITH EXHAUST FANS
42U CABINET DOORS – FRONT AND REAR SIDES
CABLE MANAGEMENT
48 PORT NETWORK SWITCH
CAT 6 24 PORT PATCH PANEL
PULL OUT KEYBOARD
POWER DISTRIBUTION UNIT
CABLE MANAGEMENT
FIBER DISTRIBUTION PANEL
VIDEO MONITOR
APPLICATION / DATABASE SERVER
UNINTERRUPTIBLE POWER SUPPLY WITH
BATTERIES
P OW E R
4-PORT WITH USB SHARE
Model : B006-VUA4-K-R
KVM SWITCH
AUTO SCAN K/M RESET
ON LINE
SELECTED
USB LINE
1 2 3 4KVM SWITCH
POWER DISTRIBUTION UNIT
CISCO NEXUS 2348TQ-ESTATID
2/1
2/2
2/3
2/4
33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 4825 26 27 28 29 30 31 3217 18 19 20 21 22 23 241 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
GROUND
NEW CABINENTS
GROUND
NEW CABINENTS
633 17th Street, Suite 1500 Denver, Colorado 80202
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 8 OF 8
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 8 OF 8
FOCN-JA007
MASSACHUSETTS BAY TRANSPORTATION AUTHORITY
FIBER OPTIC COMMUNICATION SYSTEM (FOCS) DESIGN
SIZE FSCM NO DWG NO REV
SCALE 1 : 1 SHEET 8 OF 8
FOCN-JA007 COMMUNICATIONS4/29/19
DSE
FIBER OPTIC CABLE CONDUIT ROUTING
BRAINTREE STATION
NOTE 1. INSTALL 2 - 2" CONDUITS BETWEEN THE TRACTION POWER SUBSTATION TO THE COMMUNICATIONS MANHOLE. FIELD MEASURE THE DISTANCE FOR ACCURACY. ANY EXPOSED CONDUIT SHALL BE GRC. TRANSITION TO SCHEDULE 80 PVC TO RUN BETWEEN BUILDING AND COMMUNICATIONS MANHOLE AT A DEPTH OF 36 INCHES BELOW FINISHED GRADE.
NOTE 2. FURNISH AND INSTALL 12F SM FO CABLE FROM TRACTION POWER SUBSTATION IN NEWLY INSTALLED CONDUIT TO COMMUNICATIONS MANHOLE. USE THE EXISTING MULE TAPE TO PULL FIBER OPTIC CABLE THOUGH TO THE SIGNAL BUNGALOW VAULT.
PULL IN ADDITIONAL MULE TAPE ALONG WITH FIBER OPTIC CABLE FOR FUTURE USE.
NOTE 3. CONTINUE THE INSTALLATION OF THE FIBER OPTIC CABLE FROM THE SIGNAL BUNGALOW VAULT ALONG THE SIGNAL BUNGALOW IN THE EXISTING LADDER RACK AND TERMINATE THE FIBER IN THE EXISITING FIBER RACK.
FIBER OPTIC CABLE
EXISTING SYSTEMS
LEGEND
FIBER OPTIC CABLE
EXISTING SYSTEMS
LEGEND
BRAINTREE STATION
SIGNAL BUNGALOW
COMMUNICATIONS
MANHOLE
COMMUNICATIONS
MANHOLE (EXISTING)
WITH MULE TAPE TO
SIGNAL BUNGALOW VAULT
TRACTION POWER SUBSTATION
TWO 2" CONDUITS TO BE
INSTALLED FROM TRACTION
POWER SUBSTATION TO
COMMUNICATIONS
MANHOLE
633 17th Street, Suite 1500 Denver, Colorado 80202 633 17th Street, Suite 1500 Denver, Colorado 80202
SIGNAL BUNGALOW
EXISITING
FIBER RACK
SIGNAL
BUNGALOW
VAULT
NOTE 1
NOTE 2
NOTE 2
NOTE 2
NOTE 3
GRC
PVC
dweinberger Callout Communications Manhole with Mule tape connected to Signal Bungalow vault dweinberger Callout cable to be pulled in ladder tray to existing fiber rack dweinberger Callout Signal vault under bungalow dweinberger Callout install two 2" conduits from TPSS underground to communications Manhole along ROW
| PLAN SET 20190428 FINAL.vsdx |
| TOC |
| FOCN-JA001 |
| FOCN-JA002 |
| FOCN-JA003 |
| FOCN-JA004 |
| FOCN-JA005 |
| FOCN-JA006 |
| FOCN-JA007 |
File details come from the government source that posted it. Updated .