#PB-3 - Sanitary Wate Piping Specialties - Substitution Request-202606091959.pdf

PDF 1 MB Posted

Attached to
RFP - Bert Goens Learning Center Pool Improvements
Solicitation number
RFP VBI 260000002079 3
Issued by
Van Buren County, Michigan

About this file

This is a Substitution Request form and RFI (Request for Information) documentation related to the Bert Goens Learning Center Pool Improvements project for Van Buren ISD in Michigan. The request, submitted on June 5, 2026, concerns sanitary waste piping specialties for trench drains and shower channel drains specified under Section 22 13 19 of the project specifications. The primary request involves substituting MIFAB P9000 series stainless steel shower channels with a custom 24-inch length configuration to accommodate the project's specific application requirements, as the standard MIFAB product line only offered lengths starting at 27 inches.

The substitution request was officially reviewed and approved on June 9, 2026, by Skylar Andrae of GMB (the project's management entity), with the determination that the custom-sized product aligns with the basis of design and can proceed. The approved substitution specifies the use of electro-polished Type 304 stainless steel channels with various grate pattern options (Quatro, Subway, Tile Inlay, Wave, Wedgewire, and Perimeter designs), each weighing 7.50 pounds. The supporting documentation indicates that MIFAB can manufacture the custom 24-inch length to accommodate this application, and submittals were required to proceed in accordance with Specification Section 01 25 00 Substitution Procedures. No cost or schedule impacts were identified as a result of this substitution approval.

View the file

Other files

File Type Posted
5-6732 E2.2.1A.pdf PDF
5-6732 P2.2.1B.pdf PDF
5-6732 A2.6.01.pdf PDF
P2.2.1B - Addendum 001.pdf PDF
A2.4.1B - Addendum 001.pdf PDF
A2.6.01 - Addendum 001.pdf PDF
087100 - Door Hardware_(ADDENDUM 001)_2026-06-04&8-32-24am.pdf PDF
5-6732 P5.1.01.pdf PDF
000110 - Table of Contents_(ADDENDUM 001)_2026-06-04&8-31-48am.pdf PDF
A5.1.01 - Addendum 001.pdf PDF
5-6732 A2.3.1B.pdf PDF
P6.1.01 - Addendum 001.pdf PDF
5-6732 A2.1.1B.pdf PDF
5-6732 M0.0.01.pdf PDF
A2.1.1B - Addendum 001.pdf PDF
A6.1.01 - Addendum 001.pdf PDF
5-6732-00 21 13-Instructions to Bidders.pdf PDF
P2.1.0B - Addendum 001.pdf PDF
5-6732 Addendum 002.pdf PDF
Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

5-6732 VBISD Bert Goens Learning Center Pool Improvements #PB-3 - Sanitary Wate Piping Specialties - Substitution Request

RFI detail

#PB-3 Sanitary Wate Piping Specialties - Substitution Request

Status Closed

Created on Jun 8, 2026 by Dawn Kirkland (GMB)

RFI type Default RFI workflow

Ball in court Dawn Kirkland (GMB)

Answered Jun 9, 2026 by Skylar Andrae (GMB)

Question

Official response

Skylar Andrae (GMB): Submittal substitution request has been reviewed. Custom sizing withstanding product appears to align with basis of design and can proceed.

By Skylar Andrae (GMB) - Jun 9, 2026, 9:24 AM EDT

Impact

Cost impact -

Schedule impact -

Other attributes

Priority High

Discipline -

Category -

Location -

Location details -

Created by Dawn Kirkland with Autodesk® Forma™ on Jun 9, 2026 at 3:58 PM EDT Page 1 of 2 https://acc.autodesk.com/build/rfis/projects/446685ae-ae62-4b82-a598-918e733d9335/?preview=50c61c75-a3a3-4c13-80d0-96ade09e4c42

5-6732 VBISD Bert Goens Learning Center Pool Improvements #PB-3 - Sanitary Wate Piping Specialties - Substitution Request

External ID -

Co-reviewer(s) -

Comments By At

No comments were added to this RFI.

Created by Dawn Kirkland with Autodesk® Forma™ on Jun 9, 2026 at 3:58 PM EDT Page 2 of 2

© Copyright 2013, CSI, 110 South Union St., Suite 100, Alexandria, VA 22314

Page ___ of ___ Form Version: January 2013 CSI Form 1.5C

SUBSTITUTION

REQUEST

(During the Bidding/Negotiating Stage)

Project:

To:

Re:

Substitution Request Number:

From:

Date:

A/E Project Number:

Contract For:

Specification Title:

Section: Page:

Description:

Article/Paragraph:

Proposed Substitution: Dow XARMOR Manufacturer: Dow Address: 1501 Larkin Center Drive, Midland, MI 48674 Phone: 1-866-583-2583 Trade Name: THERMAX XARMOR™ (ci) Model No.:

Attached data includes product description, specifications, drawings, photographs, and performance and test data adequate for evaluation of the request; applicable portions of the data are clearly identified.

Attached data also includes a description of changes to the Contract Documents that the proposed substitution will require for its proper installation.

The Undersigned certifies:

Proposed substitution has been fully investigated and determined to be equal or superior in all respects to specified product.

Same warranty will be furnished for proposed substitution as for specified product.

Same maintenance service and source of replacement parts, as applicable, is available.

Proposed substitution will have no adverse effect on other trades and will not affect or delay progress schedule.

Proposed substitution does not affect dimensions and functional clearances.

Payment will be made for changes to building design, including A/E design, detailing, and construction costs caused by the substitution.

Submitted by:

Signed by:

Firm:

Address:

Telephone:

A/E’s REVIEW AND ACTION

Substitution approved - Make submittals in accordance with Specification Section 01 25 00 Substitution Procedures.

Substitution approved as noted - Make submittals in accordance with Specification Section 01 25 00 Substitution Procedures.

Substitution rejected - Use specified materials.

Substitution Request received too late - Use specified materials.

Signed by: Date:

Supporting Data Attached: Drawings Product Data Samples Tests Reports

Quality Water & Air, Inc.

MIFAB 1321 West 119th St Chicago, IL 1-800-465-2736 Plumbing

Dawn Cole @ Quality Water & Air, Inc.

Quality Water & Air, Inc.

1402 Souter Troy, MI 48083

248-589-8010

Van Buren ISD Bert Goens Learning Center

Pool Improvements

Dawn Kirkland @ GMB June 05, 2026

5-6732

TD-1 Trench Drains

Sanitary Waste Piping Specialties

22 13 19 2 of 4 2.3 - Shower Channel Drains

TD-1

MIFAB P9000 series SS shower channels

P9000-QT-24

MODEL NUMBER LENGTH GRATE PATTERN WEIGHT (lbs.)

P9000-QT-27 27" Quatro 7.50 P9000-QT-32 32" Quatro 7.50 P9000-QT-36 36" Quatro 7.50 P9000-QT-42 42" Quatro 7.50 P9000-QT-48 48" Quatro 7.50 P9000-QT-56 56" Quatro 7.50 P9000-SB-27 27" Subway 7.50 P9000-SB-32 32" Subway 7.50 P9000-SB-36 36" Subway 7.50 P9000-SB-42 42" Subway 7.50 P9000-SB-48 48" Subway 7.50 P9000-SB-56 56" Subway 7.50 P9000-TI-27 27" Tile Inlay 7.50 P9000-TI-32 32" Tile Inlay 7.50 P9000-TI-36 36" Tile Inlay 7.50

P9000 ALL STAINLESS STEEL

SHOWER CHANNELS

Page No:

Contractor:

Purchase Order No:

Job Name:

Section No:

Schedule No:

Location:

USA: 1-800-465-2736 www.mifab.com CAN: 1-800-387-3880MIFAB reserves the right to make changes in material and design without formal notice and obligation.

Specification: MIFAB® Series of Stainless Steel Shower Drains are tested and certified to the ASME A112.6.3 Standard and are listed with I.A.P.M.O.

Features:

• Stainless Steel channels available in 27”, 32”, 36”, 42” 48” & 56” lengths.

• Narrow width body to align flush against wall.

• Electro-polished Type 304 Stainless Steel grates in various designs.

Also includes:

• 2” (51mm) spigot outlet.

• Hair strainer and grate lifting key.

• Rubber gasket, membrane clamp and 2” PVC socket outlet body.

Optional:

• 2” no hub outlet cast iron body & membrane clamp. (See Page 13 for dimensions.

CALIFORNIA PROPOSITION 65 WARNING. This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.

2024-02-15

CROSS SECTION VIEW OF

P9000 CHANNEL

PLAN AND SIDE VIEW OF

P9000 CHANNEL

(Illustrated with Quatro grate)

LENGTH

(See chart below)

1 1/2" MIN

3" MAX

P9000-KEY

Grate Lifting Key

P9000-POG

Rubber Gasket

P9002-PS

Hair Strainer

P9002-DB-31

2" PVC body / clamp

3 3/8" (85mm)

2 1/2" (63mm)3/4" (19mm)

2" PVC

socket outlet

3 3/8" (85mm)

1 1/2" (38mm) to 3"

(76mm)

2 1/2" (63mm)

1" (25mm)

(Illustrated with Quatro grate)

Compliance

HEELPROOF

ADA

MODEL NUMBER LENGTH GRATE PATTERN WEIGHT (lbs.)

P9000-WV-27 27" Wave 7.50 P9000-WV-32 32" Wave 7.50 P9000-WV-36 36" Wave 7.50 P9000-WV-42 42" Wave 7.50 P9000-WV-48 48" Wave 7.50 P9000-WV-56 56" Wave 7.50 P9000-WW-27 27" Wedgewire 7.50 P9000-WW-32 32" Wedgewire 7.50 P9000-WW-36 36" Wedgewire 7.50 P9000-WW-42 42" Wedgewire 7.50 P9000-WW-48 48" Wedgewire 7.50 P9000-WW-56 56" Wedgewire 7.50

QUATRO

TILE INLAY

WEDGEWIRE

WAVE

SUBWAY

GRATE OPTIONS

(3/8" recess)

P9000-TI-42 42" Tile Inlay 7.50 P9000-TI-48 48" Tile Inlay 7.50 P9000-TI-56 56" Tile Inlay 7.50

PERIMETER

P9000-PD-27 27" Perimeter 7.50 P9000-PD-32 32" Perimeter 7.50 P9000-PD-36 36" Perimeter 7.50 P9000-PD-42 42" Perimeter 7.50 P9000-PD-48 48" Perimeter 7.50 P9000-PD-56 56" Perimeter 7.50

TD-1

www.mifab.com Dawn Cole Text Box

MIFAB CAN MAKE A CUSTOM LENGTH OF 24" LONG TO ACCOMODATE THIS APPLICATION.

RFI detail
#PB-3 Sanitary Wate Piping Specialties - Substitution Request
Question
Official response
Impact
Other attributes

File details come from the government source that posted it. Updated .