5-6732 P2.2.1B.pdf

PDF 124 KB Posted

Attached to
RFP - Bert Goens Learning Center Pool Improvements
Solicitation number
RFP VBI 260000002079 3
Issued by
Van Buren County, Michigan

About this file

This is a foundation plumbing plan drawing for the Bert Goens Learning Center Pool Improvements project located in Lawrence, Michigan, prepared for the Van Buren Intermediate School District. The drawing, designated as Unit 'B' Foundation Plumbing Plan (sheet P2.2.1B), depicts the plumbing layout and connections for the pool improvement project at a scale of 1/8" = 1'-0". The plan includes specifications for sump pumps connecting to a new 2" sanitary force main, existing sumps to remain, foundation drain pumps to storm systems, wastewater connections to various fixtures including water closets and lavatories, and provisions for sealing an abandoned existing pool drain inlet. The document indicates key project milestones including a bids and construction date of May 21, 2026, with addendum submissions dated June 2, 2026 and June 9, 2026, reflecting modifications to the project scope or specifications during the bidding phase.

The drawing serves as a technical specification document for contractors preparing bids on the pool improvements project. The plan references related plumbing details documented in drawing 1/P6.1.01 and is part of a larger construction document set that includes multiple units (Units A, B, and C). No specific pricing information, budget allocations, or funding sources are identified within this technical drawing, as it functions primarily as a design and construction specification guide for the mechanical and plumbing systems required for the foundation of Unit B in the pool improvement project.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EX. 4" SAN

2" SAN (FM)

2 - SUMP PUMPS.

CONNECT TO NEW

2" SANITARY FORCE

MAIN

REFER TO 1/P6.1.01

FOR DETAILS.

2" SAN

2" SAN

4" SAN

EX. 4" SAN

UP TO WC-1A.

UP TO LAV-1A(S)

UP TO LAV-1A(S)

UP TO TD-1

UP TO TD-1

EXISTING SUMPS TO

REMAIN. FOR

FOUNDATION DRAIN

PUMPS TO STORM.

(EXISTING)

SEAL EXISTING

POOL DRAIN INLET

(ABANDONED)

3" POOL

DD-1

DD-1

DD-1DD-1

DD-1

DD-1DD-1

DD-1

PROJECT NO.

DRAWN

REVIEWED

NO PART OF THIS DRAWING MAY BE

USED OR REPRODUCED IN ANY FORM

OR BY ANY MEANS, OR STORED IN A

DATA BASE OR RETRIEVAL SYSTEM,

WITHOUT PRIOR WRITTEN

PERMISSION OF

ALL RIGHTS RESERVED

c

KEYPLAN

ISSUANCES

GMB COPYRIGHT

Au to de sk

D oc s:

//5

-6

VB

IS

D

B er t G oe ns L ea rn in g

C en te r P oo l I m pr ov em en ts

/5 -6

2P

5.

rv t

6/ 9/

:0

7:

A M

P2.2.1B

5-6732

UNIT 'B' FOUNDATION

PLUMBING PLAN

STA

RTF

B E

R T

G O

E N

S L

E A

R N

IN

G

C E

N T

E R

P O

O L

IM

P

R O

V E

M E

N T

S

V A

N B

U R

E N

IN

TE

R M

E D

IA

TE

S C

H O

O L

D

IS

TR

IC

T

LA

W R

E N

C E

M

IC

H

IG

A

N

1/8" = 1'-0"

UNIT 'B' FOUNDATION PLUMBING PLAN

UNIT A

UNIT B

UNIT C

05.21.2026 BIDS &

CONSTRUCTION

06.02.2026 ADDENDUM 001

06.09.2026 ADDENDUM 002