This document package includes construction drawings and specifications for an expansion of a Department of Veterans Affairs parking garage located in Salt Lake City, Utah. The drawings detail proposed additions to levels B, G, and 1 of the existing parking structure, including new ramps, columns, lighting plans, life safety plans, and alternates. Key details include expanding total parking capacity from 15,100 to 20,000 vehicles, adding a new south entry drive, and potential deductive alternates for items such as a video display screen, security cameras, restriping, and roofing work.

The related federal contract opportunity is a solicitation from the VA seeking proposals for guest WiFi and wayfinding services to be provided at the same Salt Lake City location. Offerors are invited to respond with solutions for a wireless network and digital signage to aid visitors in navigating the medical center campus. The solicitation includes the number, issuing agency name and location, and a brief high-level description of the services sought.

View the file

Other files for this federal contract opportunity

Other files attached to S119--Guest Wifi and Wayfinding, newest first.
File Type Posted
36C25920Q0490 0006.docx DOCX document
36C25920Q0490 0005.pdf PDF
Higher Density 1 OF 2 Medical Center Floor Plans B.1-14 1-2017 Update.pdf PDF
36C25920Q0490 0004.docx DOCX document
Modified PWS.docx DOCX document
Additional Questions and Answers to Wifi and Wayfinding.docx DOCX document
tunnel.pdf PDF
36C25920Q0490 0003.pdf PDF
Wifi and Wayfinding Walk through Roster.pdf PDF
B1-2.pdf PDF
Info for Higher Density Requirements 1 OF 2 Medical Center Floor Plans B.1-14 1-2017 Update.pdf PDF
36C25920Q0490 0002.docx DOCX document
Bld 32.pdf PDF
36C25920Q0490 0001_1.docx DOCX document
36C25920Q0490 0001.docx DOCX document
1 OF 2 Medical Center Floor Plans B.1-14 1-2017 Update.pdf PDF
2 OF 2 Medical Center Floor Plans B.16-90 1-2017 update.pdf PDF
36C25920Q0490_1.docx DOCX document
Contractor letter template.pdf PDF
36C25920Q0490.docx DOCX document
VHA Handbook 6500.6 Contract Security Appendix C.docx DOCX document
Trailers.pdf PDF
WD 15-5489.txt TXT text file
QASP Wi-Fi and Wayfinding.doc DOC document
Show all 24

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

VAN VAN VAN

VANVANVAN

S

S

S

STOP

STOP

STOP

STOP

S

S

S

S

S

S

S S S

S S S

S S S S

S

S

S

S

S

S

S

S

S

S S S S S S S S S S S S S

S S

S S

S

S

S

S

S

SS S SS

S

S

S S SS S S S S

S

S

S S S

S S S S

S S S SS S S S S S

S S S S S S

S S S S S S S S S S S

S S S S S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S S

S S S

S S S S S S S S

S S S S S S S S S S S SS S S S S

S S S S S S S S S S S S S S

S S S S S S S S S S S S

KEY PLAN

LEVEL "B"

LEVEL "G"

EL 100-0"

EL 114'-4"

LEVEL "1"

EL 128'-8"

DIAGONAL DISTANCE = 511'

DISTANCE BETWEEN EXITS = 440' > 1/2 DIAGONAL DISTANCE

72870 SF

200365 S

140 SF

S 125 SF

S 152 SF

S

146 SF

S

175 SF

S

1626 SF

S

A B C D F G H J K L M N P Q R TSA.5 D.6 E F.5

3.3

4.7

4.5

3.6

2.2

4.1

FEC

FECFECFEC

FEC

FEC FEC

EXIT

EXIT

EX

IT

EX

IT

FEC

EXIT

EXIT

EXIT

EX

IT

MAINT.

CCTV SECURITY

ELECTRICAL

ELEVATOR LOBBY

ELEV. EQUIP

AUX.

GARAGE STORAGE

PARKING

EX

IT

EX

IT

EX

IT

EX

IT

EX

IT

EX

IT

EX

IT

EXIT

EXIT

EXIT

EX

IT

EX

IT

D.3 L.4 L.9

1.7

1.6

STAIR 2

STAIR 1

MAX TRAVEL DISTANCE = 293'

EX

IT

CODE ANALYSIS LEGEND

TOTAL OCCUPANCY

Occ.

15100 1150 SF

FEC

EXIT

OCCUPANCY LOAD FACTOR

EXITS REQUIRED

SQUARE FOOTAGE

OCCUPANCY TYPE

EGRESS EXIT SIGNAGE

FIRE EXTINGUISHER CABINET

DIAGONAL DISTANCE

EXIT SEPARATION DISTANCE

EGRESS PATH

2 HR - FIRE SEPARATION

Drawing Title

Approved for Design Concept:

Project Title

Date

Location

Checked By:

Building Number

Project Number

Drawing Number

Drawn By:

Revisions: Date

ARCHITECT/ENGINEERS:

GEORGE E WAHLEN VAMC

#48 o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

OFFICE OF

FACILITIES

MANAGEMENT

VA Project Number

FACILITY MANAGEMENT

DIVISION MANAGER

660-336

MEP Engineer

APOGEE CONSULTING

GROUP

1151 Kildaire Farm Road Suite 120 Cary, NC 27511

Tele: 919-858-7420

Functional Design

CARL WALKER INC.

2801 Network Boulevard Suite 101 Frisco, TX 75034

Tele: 469-777-5143

905 N. CAPITOL AVE. SUITE 100 INDIANAPOLIS, IN. 46204

317.800.6388 WWW.GUIDONDESIGN.COM

SUSTAINABLE ARCHITECTURE + ENGINEERING

PROJECT LEAD

Architect, Structural Engineer, Civil Engineer

VAMC SALT LAKE CITY

500 Foothill Dr. Salt Lake City, UT 84148

Local Architect

AXIS ARCHITECTS

927 S. State Street Salt Lake City, UT 84111

Tele: 801-355-3003

C :\U se rs

\ll yn ch \D oc um en ts

\1 4.

-A -S

LC

P ar ki ng G ar ag e_ lly nc h.

rv t

100% CONSTRUCTION DOCUMENTS

GI102

LALLJL

LEVEL B LIFE SAFETY PLAN

2015/03/25

14.1056EXPAND PARKING

GARAGE - PHASE 2

SCALE: 1/16" = 1'-0"GI102

1 LEVEL B LIFE SAFETY

LIFE SAFETY PLAN NOTES

Keynote - Mark Keynote - Description

1 EXISTING FIRE PROTECTION SYSTEM. WHERE DEMO TO OCCUR,

F.P. WILL BE REMOVED, CAPPED, AND NOT EXPANDED TO NEW

CONSTRUCTION

2 EMERGENCY LIGHTING AND EXIT SIGNS PER ELECTRICAL

N

NOTE: CONTRACTOR TO PROVIDE PORTABLE FIRE EXTINGUISHERS THROUGHOUT GARAGE

AS REQUIRED BY IFC SECTION 906.1 AND SPACED IN ACCORDANCE WITH NFPA 10,

2010 EDITION

DN

DN

UP

DN

RAMP 5.1%

VAN VAN VAN

VANVANVAN

S S

S S

S

S

SS S SS S S SS S S SSS S S

S S

S S

S S

S

STOP

STOP

STOP

S S

S S

S

S

S S

S S

S S S

S S S

S S S

S S

S S S S SS S S S S S S S S S S S S SS S S S S S S S S

S S S

S S S S

S S

S S

S S S S S S

S S S S S S

S

S

S S SS S

S S S S S

S S S S

S S S S S S SS

S S S S

S S S SS S S S S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S S S S S

S S S S S S S S S S S S S SS S

S S S S S S S S S S S S S S

KEY PLAN

LEVEL "B"

LEVEL "G"

EL 100-0"

EL 114'-4"

LEVEL "1"

EL 128'-8"

DIAGONAL DISTANCE = 511'DISTANCE BETWEEN EXITS = 351' > 1/2 DIAGONAL DISTANCE

79722 SF

200399 S

149 SF

S 130 SF

S 157 SF

S

146 SF

S

128 SF

S

A B C D F G H J K L M N P Q R TSA.5 D.6 E F.5

3.3

4.7

4.5

3.6

2.2

4.1

FEC

FEC

FEC

FEC

FEC

FECFEC

FEC

FEC

EX

IT

EXIT

EX

IT

EXIT

EX

IT

EX

IT

EX

IT

EX

IT

EX

IT

EXIT

EXIT

EXIT

EXIT

SHOP

TELE/DATA

SPRINK/RISER

ELEVATOR LOBBY

WC STOR

PARKING

AUX

EX

IT

EX

IT

EX

IT

EX

IT

EX

IT

EX

IT

EXIT EX

IT

EX

IT

EX

IT

D.3 L.4 L.9

1.7

1.6

STAIR 1

STAIR 2

STAIR 3

MAX TRAVEL DISTANCE = 293'

CODE ANALYSIS LEGEND

TOTAL OCCUPANCY

Occ.

15100 1150 SF

FEC

EXIT

OCCUPANCY LOAD FACTOR

EXITS REQUIRED

SQUARE FOOTAGE

OCCUPANCY TYPE

EGRESS EXIT SIGNAGE

FIRE EXTINGUISHER CABINET

DIAGONAL DISTANCE

EXIT SEPARATION DISTANCE

EGRESS PATH

2 HR - FIRE SEPARATION

Drawing Title

Approved for Design Concept:

Project Title

Date

Location

Checked By:

Building Number

Project Number

Drawing Number

Drawn By:

Revisions: Date

ARCHITECT/ENGINEERS:

GEORGE E WAHLEN VAMC

#48 o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

OFFICE OF

FACILITIES

MANAGEMENT

VA Project Number

FACILITY MANAGEMENT

DIVISION MANAGER

660-336

MEP Engineer

APOGEE CONSULTING

GROUP

1151 Kildaire Farm Road Suite 120 Cary, NC 27511

Tele: 919-858-7420

Functional Design

CARL WALKER INC.

2801 Network Boulevard Suite 101 Frisco, TX 75034

Tele: 469-777-5143

905 N. CAPITOL AVE. SUITE 100 INDIANAPOLIS, IN. 46204

317.800.6388 WWW.GUIDONDESIGN.COM

SUSTAINABLE ARCHITECTURE + ENGINEERING

PROJECT LEAD

Architect, Structural Engineer, Civil Engineer

VAMC SALT LAKE CITY

500 Foothill Dr. Salt Lake City, UT 84148

Local Architect

AXIS ARCHITECTS

927 S. State Street Salt Lake City, UT 84111

Tele: 801-355-3003

C :\U se rs

\ll yn ch \D oc um en ts

\1 4.

-A -S

LC

P ar ki ng G ar ag e_ lly nc h.

rv t

100% CONSTRUCTION DOCUMENTS

GI103

LALLJL

LEVEL G LIFE SAFETY PLAN

2015/03/25

14.1056EXPAND PARKING

GARAGE - PHASE 2

SCALE: 1/16" = 1'-0"GI103

1 LEVEL G LIFE SAFETY

LIFE SAFETY PLAN NOTES

Keynote - Mark Keynote - Description

1 EXISTING FIRE PROTECTION SYSTEM. WHERE DEMO TO OCCUR,

F.P. WILL BE REMOVED, CAPPED, AND NOT EXPANDED TO NEW

CONSTRUCTION

2 EMERGENCY LIGHTING AND EXIT SIGNS PER ELECTRICAL

N

NOTE: CONTRACTOR TO PROVIDE PORTABLE FIRE EXTINGUISHERS THROUGHOUT GARAGE

RAMP 5.1%

S S S S S S S

STOP

STOPS S S S S

S

S S S S

S S

S S

S

S

S S

S S

S S

S

S S

S S

S S S

S S S

S SS S S S S S S S S S S S S SSS S S S S S S

S S

S S

SS S S

S SS S SS S S SS S S S

S S

S S

S S

S

S

S

S

S S

S S

S S SS S

S S S

S S S S S S S S S S S S S

S S S S S S S S S S S S S

S S S S S S

S S S S S S S S S S S

S S S S S S

S S SS S

S S S S S

S S S S

S S S S

S S S

S S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S

S S S S S S S S S S S S S S

STOP

DN

DN

DN

KEY PLAN

LEVEL "B"

LEVEL "G"

EL 100-0"

EL 114'-4"

LEVEL "1"

EL 128'-8"

DIAGONAL DISTANCE = 511'

DISTANCE BETWEEN EXITS = 350' > 1/2 DIAGONAL DISTANCE

MAX TRAVEL DISTANCE = 293'

74546 SF

200373 S

49 SF

S

128 SF

S

A B C D F G H J K L M N P Q R TSA.5 D.6 E F.5

3.3

4.7

4.5

3.6

2.2

4.1

FEC

FEC FEC FEC

FECFECFEC FEC

FEC

FEC

EXIT

EX

IT

PARKING

AUX

ELEVATOR LOBBY

ELEC

EX

IT

EXIT

EX

IT

EX

IT

EXIT EX

IT

EX

IT

EX

IT

EX

IT

EXIT

EXIT

EX

IT

EXIT

EX

IT

EXIT

EX

IT

EX

IT

EX

IT

EX

IT

EX

IT

EX

IT

EXIT

D.3 L.4 L.9

1.7

1.6

STAIR 3

STAIR 2

STAIR 1

CODE ANALYSIS LEGEND

TOTAL OCCUPANCY

Occ.

15100 1150 SF

FEC

EXIT

OCCUPANCY LOAD FACTOR

EXITS REQUIRED

SQUARE FOOTAGE

OCCUPANCY TYPE

EGRESS EXIT SIGNAGE

FIRE EXTINGUISHER CABINET

DIAGONAL DISTANCE

EXIT SEPARATION DISTANCE

EGRESS PATH

2 HR - FIRE SEPARATION

Drawing Title

Approved for Design Concept:

Project Title

Date

Location

Checked By:

Building Number

Project Number

Drawing Number

Drawn By:

Revisions: Date

ARCHITECT/ENGINEERS:

GEORGE E WAHLEN VAMC

#48 o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

OFFICE OF

FACILITIES

MANAGEMENT

VA Project Number

FACILITY MANAGEMENT

DIVISION MANAGER

660-336

MEP Engineer

APOGEE CONSULTING

GROUP

1151 Kildaire Farm Road Suite 120 Cary, NC 27511

Tele: 919-858-7420

Functional Design

CARL WALKER INC.

2801 Network Boulevard Suite 101 Frisco, TX 75034

Tele: 469-777-5143

905 N. CAPITOL AVE. SUITE 100 INDIANAPOLIS, IN. 46204

317.800.6388 WWW.GUIDONDESIGN.COM

SUSTAINABLE ARCHITECTURE + ENGINEERING

PROJECT LEAD

Architect, Structural Engineer, Civil Engineer

VAMC SALT LAKE CITY

500 Foothill Dr. Salt Lake City, UT 84148

Local Architect

AXIS ARCHITECTS

927 S. State Street Salt Lake City, UT 84111

Tele: 801-355-3003

C :\U se rs

\ll yn ch \D oc um en ts

\1 4.

-A -S

LC

P ar ki ng G ar ag e_ lly nc h.

rv t

100% CONSTRUCTION DOCUMENTS

GI104

LALLJL

LEVEL 1 LIFE SAFETY PLAN

2015/03/25

14.1056EXPAND PARKING

GARAGE - PHASE 2

SCALE: 1/16" = 1'-0"GI104

1 LEVEL 1 LIFE SAFETY

LIFE SAFETY PLAN NOTES

Keynote - Mark Keynote - Description

1 EXISTING FIRE PROTECTION SYSTEM. WHERE DEMO TO OCCUR,

F.P. WILL BE REMOVED, CAPPED, AND NOT EXPANDED TO NEW

CONSTRUCTION

2 EMERGENCY LIGHTING AND EXIT SIGNS PER ELECTRICAL

N

NOTE: CONTRACTOR TO PROVIDE PORTABLE FIRE EXTINGUISHERS THROUGHOUT GARAGE

VAN VAN VAN

VANVANVAN

S

S

S

STOP

STOP

STOP

STOP

S

S

S

S

S

S

S S S

S S S

S S S S

S

S

S

S

S

S

S

S

S

S S S S S S S S S S S S S

S S

S S

S

S

S

S

S

SS S SS

S

S

S S SS S S S S

S

S

S S S

S S S S

S S S SS S S S S S

S S S S S S

S S S S S S S S S S S

S S S S S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S S

S S S

S S S S S S S S

S S S S S S S S S S S SS S S S S

S S S S S S S S S S S S S S

S S S S S S S S S S S S

RAMP 5.1%

VAN VAN VAN

VANVANVAN

S S

S S

S

S

SS S SS S S SS S S SSS S S

S S

S S

S S

S

STOP

STOP

STOP

S S

S S

S

S

S S

S S

S S S

S S S

S S S

S S

S S S S SS S S S S S S S S S S S S SS S S S S S S S S

S S S

S S S S

S S

S S

S S S S S S

S S S S S S

S

S

S S SS S

S S S S S

S S S S

S S S S S S SS

S S S S

S S S SS S S S S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S S S S S

S S S S S S S S S S S S S SS S

S S S S S S S S S S S S S S

RAMP 5.1%

S S S S S S S

STOP

STOPS S S S S

S

S S S S

S S

S S

S

S

S S

S S

S S

S

S S

S S

S S S

S S S

S SS S S S S S S S S S S S S SSS S S S S S S

S S

S S

SS S S

S SS S SS S S SS S S S

S S

S S

S S

S

S

S

S

S S

S S

S S SS S

S S S

S S S S S S S S S S S S S

S S S S S S S S S S S S S

S S S S S S

S S S S S S S S S S S

S S S S S S

S S SS S

S S S S S

S S S S

S S S S

S S S

S S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S

S S S S S S S S S S S S S S

STOP

RAMP 5.1%

S S S S S S S

STOP

STOPS S S S S

S

S S S S

S S

S S

S

S

S S

S S

S S

S

S S

S S

S S S

S S S

S SS S S S S S S S S S S S S SSS S S S S S S

S S

S S

SS S S

S SS S SS S S SS S S S

S S

S S

S S

S

S

S

S

S S

S S

S S SS S

S S S

S S S S S S S S S S S S S

S S S S S S S S S S S S S

S S S S S S

S S S S S S S S S S S

S S S S S S

S S SS S

S S S S S

S S S S

S S S S

S S S

S S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S

S S S S S S S S S S S S S S

STOP

BID ALTERNATES

ALT

DEDUCT LED VIDEO DISPLAY SCREEN ON WEST ELEVATION.

DEDUCT RESTRIPING OF EXISTING GARAGE LEVELS.

DEDUCT SECURITY CAMERAS. RE SHEETS: E-101, E-102, E-103

DEDUCT TEMPORARY PARKING. RE SHEET: CS102

DEDUCT THE NEW ROOF, METAL SCREEN TO END 96" AFF.

DEDUCT REINSTALLATION OF EXISTING ROOF.

DESCRIPTION

A

B

C

D

E

F

DO NOT RE-INSTALL EXISTING ROOF ON TOP OF FIRST LEVEL, BETWEEN GRIDS (H AND T), IN ITS ENTIRETY. REPLACE LIGHTING WITH POLES AS NOTED ON SHEET 1/E105. INSTALL PERIMETER STEEL COLUMNS AND PERIMETER BEAMS AS DETAILED ON 1/SF102. THIS AREA DEDUCT INCLUDES: ROOF MEMBRANE, STEEL DECKING, INTERIOR STEEL COLUMNS, BIRD NETTING, REDUCED ELECTRICAL AND LIGHTING AND ALL OTHER ASSOCIATED ITEMS SHOWN AS BASE BID IN

THIS LOCATION.

ALTERNATE F DESCRIPTION:

INDICATES AREAS TO

DEDUCT ROOF.

DO NOT INSTALL NEW ROOF COVERING NEW PORTION OF GARAGE, BETWEEN GRIDS (A AND G), IN ITS ENTIRETY. REPLACE LIGHTING WITH POLES AS NOTED ON SHEET 1/E104. INSTALL PERIMETER STEEL COLUMNS AND PERIMETER BEAMS AS DETAILED ON 1/SF102. THIS AREA DEDUCT INCLUDES: ROOF MEMBRANE, STEEL DECKING, INTERIOR STEEL COLUMNS, BIRD NETTING, REDUCED ELECTRICAL AND LIGHTING AND ALL OTHER ASSOCIATED ITEMS SHOWN AS BASE

BID IN THIS LOCATION.

ALTERNATE E DESCRIPTION:

INDICATES AREAS TO

DEDUCT ROOF.

ALTERNATE A

ALTERNATE A DESCRIPTION:

REMOVE LED VIDEO DISPLAY SCREEN, ASSOCIATED STRUCTURAL, ELECTRICAL, AND TELECOM WORK. PROVIDE PANEL TYPE "B6" AND ALL ASSOCIATED WORK

IN ITS ENTIRETY TO REPLACE LED SCREEN.

DO NOT PROVIDE TEMPORARY PARKING FOR HOSPITAL DURING CONSTRUCTION. SEE SHEET CS102

ALTERNATE D DESCRIPTION:

DO NOT PROVIDE 360° OR 270° PoE SECURITY CAMERAS AND ASSOCIATED WIRING . SEE SHEETS E-101, E-102 AND E-103 FOR DETAILS, LOCATION AND NUMBER OF CAMERAS TO DEDUCT.

ALTERNATE C DESCRIPTION:

LEVEL B

LEVEL G

DO NOT RE-STRIP EXISTING GARAGE LEVELS. KEEP EXISTING STRIPPING AS IT IS

CURRENTLY AND MODIFY ONLY AS NEEDED FOR NEW SOUTH ENTRY DRIVE.

ALTERNATE B DESCRIPTION:

INDICATES AREAS TO DEDUCT

STRIPING AND KEEP EXISTING.

OPEN TO BELOW

OPEN TO BELOW

Drawing Title

Approved for Design Concept:

Project Title

Date

Location

Checked By:

Building Number

Project Number

Drawing Number

Drawn By:

Revisions: Date

ARCHITECT/ENGINEERS:

GEORGE E WAHLEN VAMC

#48 o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

OFFICE OF

FACILITIES

MANAGEMENT

VA Project Number

FACILITY MANAGEMENT

DIVISION MANAGER

660-336

MEP Engineer

APOGEE CONSULTING

GROUP

1151 Kildaire Farm Road Suite 120 Cary, NC 27511

Tele: 919-858-7420

Functional Design

CARL WALKER INC.

2801 Network Boulevard Suite 101 Frisco, TX 75034

Tele: 469-777-5143

905 N. CAPITOL AVE. SUITE 100 INDIANAPOLIS, IN. 46204

317.800.6388 WWW.GUIDONDESIGN.COM

SUSTAINABLE ARCHITECTURE + ENGINEERING

PROJECT LEAD

Architect, Structural Engineer, Civil Engineer

VAMC SALT LAKE CITY

500 Foothill Dr. Salt Lake City, UT 84148

Local Architect

AXIS ARCHITECTS

927 S. State Street Salt Lake City, UT 84111

Tele: 801-355-3003

C :\U se rs

\ll yn ch \D oc um en ts

\1 4.

-A -S

LC

P ar ki ng G ar ag e_ lly nc h.

rv t

100% CONSTRUCTION DOCUMENTS

GI105

LALLJL

ALTERNATES

2015/03/25

14.1056EXPAND PARKING

GARAGE - PHASE 2

NOT TO SCALEGI105

6 ALTERNATE A

NOT TO SCALEGI105

1 ALTERNATE D

NOT TO SCALEGI105

7 ALTERNATE C

NOT TO SCALEGI105

8 ALTERNATE B

NOT TO SCALEGI105

11 LEVEL 1 FLOOR PLAN

NOT TO SCALEGI105

2 LEVEL 1 FLOOR PLAN

Drawing Title

Approved for Design Concept:

Project Title

Date

Location

Checked By:

Building Number

Project Number

Drawing Number

Drawn By:

Revisions: Date

ARCHITECT/ENGINEERS:

GEORGE E WAHLEN VAMC

#48 o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

OFFICE OF

FACILITIES

MANAGEMENT

VA Project Number

FACILITY MANAGEMENT

DIVISION MANAGER

660-336

MEP Engineer

APOGEE CONSULTING

GROUP

1151 Kildaire Farm Road, Suite 120, Cary, NC 27511

Tele: 919-858-7420

Functional Design

CARL WALKER INC.

2801 Network Boulevard Suite 101 Frisco, TX 75034

Tele: 469-777-5143

905 N. CAPITOL AVE. SUITE 100 INDIANAPOLIS, IN. 46204

317.800.6388 WWW.GUIDONDESIGN.COM

SUSTAINABLE ARCHITECTURE + ENGINEERING

PROJECT LEAD

Architect, Structural Engineer, Civil Engineer

VAMC SALT LAKE CITY

500 Foothill Dr. Salt Lake City, UT 84148

Local Architect

AXIS ARCHITECTS

927 S. State Street Salt Lake City, UT 84111

Tele: 801-355-3003

C U s e rs

\b th o m a s \D o c u m e n ts

\1 .1

-S

-S a lt L a k e C it y V

A b th o m a s .r v t

100% CONSTRUCTION DOCUMENTS

SF901

WJTMAV

ISOMETRICS

2015/03/25

14.1056EXPAND PARKING

GARAGE - PHASE 2

SCALE:SF901

1 NORTHWEST ISOMETRIC

SCALE:SF901

2 SOUTHWEST ISOMETRIC

SCALE:SF901

3 NORTHEAST ISOMETRIC

SCALE:SF901

4 SOUTHEAST ISOMETRIC

NOTE: ARCHITECTURAL ELEMENTS

NOT SHOWN FOR CLARITY

File details come from the government source that posted it. Updated .