P500_FINAL_DESIGN_DWGS-Vol4_SIGNED.pdf
PDF 14 MB Posted
- Solicitation number
- N6274223R1302
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HYD
FOD CONTROL
FOD CONTROL
12-4
3-4
A3
C
C
J
A332
A3
C
C
J
C17 C30J
A3
C
C
J
A3
C
C
J
A332
C17 C30J
A332
C17 C30J
A332
C17 C30J
PARKING CLEARANCE
PARKING CLEARANCE
PARKING CLEARANCE
PA
RK
IN
G
CL
EA
RA
NC
E
PA
RK
IN
G
CL
EA
RA
NC
E
PA
RK
IN
G
CL
EA
RA
NC
E
PA
RK
IN
G
CL
EA
RA
NC
E
PA
RK
IN
G
CL
EA
RA
NC
E
PA
RK
IN
G
CL
EA
RA
NC
E
PARKING CLEARANCE
PARKING CLEARANCE
PARKING CLEARANCE
PARKING CLEARANCE
PARKING CLEARANCE
PARKING CLEARANCE
E E
E
E E
E
E
E
E
E
E
SUB 040
SUB 034
NE W SUBA
NE WS UB B
S UB 42
SUB 03
RM
RM RM RM RM RM RM RM RM RM RM RM RM RM RM RM RM RM RM RM RM RM RM RM RM RM
RM
RM
RM
RM RM
RM
RM RM RM RM RM RM RM RM RM RM
W
W
W
W
W W W W W W W W W W W
W
W W W
W
W W
W
W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W
W
CV
SV
SVCV
SV CV
SV
CV
CVSVCV
SV
DN
0x
TA
PE
R
SV
SV
AV
SV SV
SVSV
SV
SV
SV
AV
SV
SPS
SV SV
AV AV
SV
SV
AV AV
SCV AV
W
W
W
W
W
W W
B3
B3CP
SMH
RM
RM RM RM RM RM RM RM RM RM RM RM RM RM RM RM RM RM RM RM RM RM RM RM RM RM
RM
RM
RM
RM RM
RM
RM RM RM RM RM RM RM RM RM RM
W
W
W
W
W W W W W W W W W W W
W
W W W
W
W W
W
W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W
W
CV
SV
SVCV
SV CV
SV
CV
CVSVCV
SV
DN
0x
TA
PE
R
SV
SV
AV
SV SV
SVSV
SV
SV
SV
AV
SV
SPS
SV SV
AV AV
SV
SV
AV AV
SCV AV
W
W
W
W
W
W W
B3
B3CP
SMH
SUB
C
C
C C C C C C
C C
C
C
C
C
C C C
C C
C
C C C C C C C
C C
C C
C C C C C C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C
C C
C
C C
C
C C C C
C C C C
C C C C C C C C C C C C C C C C C C C C C
C C C C C C
C C
C
C
C
C C C
C
C C
C C C
C C C
C
C C
C C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
D
B-52H B-52H B-52H B-52H B-52H B-52H B-52H B-52HB-52H B-52H B-52H B-52H
TAXIWAY A
USAF BOMBER APRON
A3
M
RT
T A3
M
RT
T
A3
M
RT
T A3
M
RT
T
A3
M
RT
T A3
M
RT
T
A3
M
RT
T A3
M
RT
T
760m
490m
270m
60m
HD1.3 AND 1.4
FINAL SUBMITTAL
C044138No.RE G I
S T
ER
ED PR O FE S S I ON A L E NG I NEER
S TA T E O F C A L I F O R N I A
300m
1:3000
X-107
GREEN SAFEGUARDING ARC
YELLOW SAFEGUARDING ARC
PURPLE SAFEGUARDING ARC
TN
PLAN
NORTH
A1EO - EXPLOSIVE ARCS PLAN
SCALE: 1:3000m
BAY 1 AND 6 HD1.1 EO ONLY
ENTIRE APRON HD1.3 AND 1.4
DATE: 03/02/2023
Evan Mizue
PO
L
PO
L
PO
L
PO
L
PO
L
PO
L
PO
L
PO
L
PO
L
PO
L
POLPOLPOL
POL POL POL POL POL POL POL POL
POLPOLPOLPOLPOL
B-52H B-52H B-52H B-52HB-52H B-52H
HV-08
C C
C
C
C
C C
C C
C C
C C
C C C C C C C C C C C C C C C C C C C
.0
15.00 15.00
.0
.0
.0
C-17A Globemaster III
C-17A Globemaster III
PE
A330 MRTT
A330 MRTT
PE
B-52HB-52H
PE
C-17A Globemaster III
C-17A Globemaster III
PE
A330 MRTT
A330 MRTT
PE
B-52HB-52H
PE
C-17A Globemaster III
C-17A Globemaster III
PE
A330 MRTT
A330 MRTT
PE
B-52HB-52H
PE
X-117
FINAL SUBMITTAL
C044138No.RE G I
S T
ER
ED PR O FE S S I ON A L E NG I NEER
S TA T E O F C A L I F O R N I A
50m
1:500
NOTES:
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH PAF180500 RAAF
TINDAL HAZARDOUS AREA AND EXPLOSIVE AREA CLASSIFICATION
REPORT.
2. AIRCRAFT SHOWN FOR ILLUSTRATIVE PURPOSES ONLY. REFER TO
DRAWINGS X-127 AND X-128 FOR THE HAZARDOUS AREA ZONES FOR
AIRCRAFT REFUELING AND DEFUELING.
EO HAZARDOUS AREA ZONE BOUNDARIES:
ELECTRICAL EQUIPMENT &
TEMPERATURE CLASS:
EQUIPMENT INTENDED FOR USE IN THE RESTRICTED ELECTRICAL AREAS
(REA) SHALL MEET THE REQUIREMENTS OF eDEOP101 REGULATION 6.3
PROCEDURE 1 ANNEX D AND PROCEDURE 3 ANNEX B.
IGNITION CAPABLE EQUIPMENT SHALL NOT ENTER THE REA PROTECTED
AREA WHILE EO IS BEING HANDLED WITHIN THE REA.
CLASSIFICATION OF HAZARDOUS AREAS ACCORDING TO eDEOP 101
RESTRICTED ELECTRICAL AREA (REA)
AN AREA CONTAINING EXPLOSIVE ORDNANCE (EO) FOR
WHICH THE EXPLOSIVE SUBSTANCE IS NOT EXPOSED TO
ATMOSPHERE. INCLUDES THE SPACE WITHIN 15m
HORIZONTALLY AND VERTICALLY FROM WHERE THE EO IS, OR
MAY BE, LOCATED.
REA PROTECTED AREA
AN AREA EXTENDING 15m LATERALLY FROM AN REA
INTENDED TO RESTRICT INGRESS OF LIKELY SOURCES
OF FLAMES, SPARKS, PROJECTILES AND RADIANT HEAT
BEING MOVED INTO THE REA.
TN
PLAN
NORTH
A1EO - MAIN APRON
SCALE: 1:500m
TAXIWAY A
NEW BOMBER APRON
SQID PAD
POL POL POL POL POL POL POL POL POL
PO
L
PO
L
PO
L
PO
L
PO
L
PO
L
POLPOLPOLPOLPOLPOLPOLPOLPOL
B-52H B-52H B-52H B-52H B-52H B-52H
C
C
C
C C
C C
C C
C
C
.0
.0
.0
.0
15.00 15.00
C-17A Globemaster III
C-17A Globemaster III
PE
A330 MRTT
A330 MRTT
PE
B-52HB-52H
PE
C-17A Globemaster III
C-17A Globemaster III
PE
A330 MRTT
A330 MRTT
PE
B-52HB-52H
PE
C-17A Globemaster III
C-17A Globemaster III
PE
A330 MRTT
A330 MRTT
PE
B-52HB-52H
PE
FINAL SUBMITTAL
C044138No.RE G I
S T
ER
ED PR O FE S S I ON A L E NG I NEER
S TA T E O F C A L I F O R N I A
50m
1:500
TN
PLAN
NORTH
A1EO - MAIN APRON
SCALE: 1:500m X-118
NOTES:
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH PAF180500 RAAF
TINDAL HAZARDOUS AREA AND EXPLOSIVE AREA CLASSIFICATION
REPORT.
2. AIRCRAFT SHOWN FOR ILLUSTRATIVE PURPOSES ONLY. REFER TO
DRAWINGS X-127 AND X-128 FOR THE HAZARDOUS AREA ZONES FOR
AIRCRAFT REFUELING AND DEFUELING.
EO HAZARDOUS AREA ZONE BOUNDARIES:
ELECTRICAL EQUIPMENT &
TEMPERATURE CLASS:
EQUIPMENT INTENDED FOR USE IN THE RESTRICTED ELECTRICAL AREAS
(REA) SHALL MEET THE REQUIREMENTS OF eDEOP101 REGULATION 6.3
PROCEDURE 1 ANNEX D AND PROCEDURE 3 ANNEX B.
IGNITION CAPABLE EQUIPMENT SHALL NOT ENTER THE REA PROTECTED
AREA WHILE EO IS BEING HANDLED WITHIN THE REA.
CLASSIFICATION OF HAZARDOUS AREAS ACCORDING TO eDEOP 101
RESTRICTED ELECTRICAL AREA (REA)
AN AREA CONTAINING EXPLOSIVE ORDNANCE (EO) FOR
WHICH THE EXPLOSIVE SUBSTANCE IS NOT EXPOSED TO
ATMOSPHERE. INCLUDES THE SPACE WITHIN 15m
HORIZONTALLY AND VERTICALLY FROM WHERE THE EO IS, OR
MAY BE, LOCATED.
REA PROTECTED AREA
AN AREA EXTENDING 15m LATERALLY FROM AN REA
INTENDED TO RESTRICT INGRESS OF LIKELY SOURCES
OF FLAMES, SPARKS, PROJECTILES AND RADIANT HEAT
BEING MOVED INTO THE REA.
SIGNAGE REQUIRED:
"RESTRICTED ELECTRICAL AREA" AS PER
AUSTRALIAN DEFENCE REQUIREMENTS
TAXIWAY A
NEW BOMBER APRON
AC
CE
SS
R
OA
D
C1 C-503
W W W W W W W W W W W W W W W W
W W
W W
W W
W W
W W W W W W W W W W W
W
B-52H B-52H
C-17A Globemaster III
C-17A Globemaster III
PE
A330 MRTT
A330 MRTT
PE
B-52HB-52H
PE
C-17A Globemaster III
C-17A Globemaster III
PE
A330 MRTT
A330 MRTT
PE
B-52HB-52H
PE
C-17A Globemaster III
C-17A Globemaster III
PE
A330 MRTT
A330 MRTT
PE
B-52HB-52H
PE
B-52H B-52H B-52H B-52H
C C
C
C
C
C C
C C
C C
C C
C C C C C C C C C C C C C C C C C C C
PO
L
PO
L
PO
L
PO
L
PO
L
PO
L
PO
L
PO
L
PO
L
PO
L
POLPOLPOL
POL POL POL POL POL POL POL POL
POLPOLPOLPOLPOL
X-504 A1 X-504
A4
ZONE 1
WITHIN EXTENT OF PIT
ZONE 2
R=1.5m FROM CENTRE OF PIT WHEN IN USE
DOUBLE LOW POINT DRAIN
ZONE 1 WITHIN
RETENTION TANKS
ZONE 1 WITHIN PIPES
AND BOX CULVERTS
HYDRANT OUTLET PIT
ZONE 2 R=0.5m FROM
EDGE OF PIT WHEN IN USE
ZONE 1 WITHIN
EXTENT OF PIT HYDRANT
OUTLET PIT
ZONE 1 WITHIN EXTENT OF PIT
LOW POINT DRAIN
ZONE 1 WITHIN EXTENT OF PIT
ZONE 2
R=1.5m FROM CENTRE OF PIT WHEN IN USE
HIGH POINT VENT
C1 X-502
ZONE 1 WITHIN
EXTENT OF PIT
ZONE 2 R=0.5m HORIZONTALLY FROM EDGE OF GRATING AND TO 0.3m ABOVE GRATING
ZONE 1 WITHIN EXTENT
OF PITS AND GRATINGS
ZONE 1 R=1.0m FROM
CENTRE OF PIT WHEN IN USE
ZONE 1
WITHIN EXTENT OF PIT
ZONE 2
R=1.5m FROM CENTRE OF PIT WHEN IN USE
HIGH POINT VENT
B3
X-503 ZONE 1 R=1.0m FROM
CENTRE OF PIT WHEN IN USE
ZONE 1 R=1.0m FROM CENTRE OF PIT WHEN IN USE
ZONE 2
R=1.5m FROM CENTRE OF PIT WHEN IN USEZONE 1 R=1.0m FROM
CENTRE OF PIT WHEN IN USE
ZONE 1 R=1.0m FROM
CENTRE OF PIT WHEN IN USE
ZONE 2
R=1.5m FROM CENTRE
OF PIT WHEN IN USE
HYDRANT
OUTLET PIT
ZONE 1 WITHIN
EXTENT OF PIT
ZONE 1 R=1.0m FROM
CENTRE OF PIT
WHEN IN USE
ZONE 2
R=1.5m FROM CENTRE
OF PIT WHEN IN USE
ZONE 2
R=0.5m FROM PIPE OUTLET
IN ALL DIRECTIONS
ZONE 2 R=0.5m FROM
EDGE OF GRATING
C1 X-502
C1 X-502
B3 X-503
D1 X-503
B1 X-503
C2 X-502
C2 X-502
C2 X-502
SQID
PAD
C1 X-505
ZONE 1 R=1.0m FROM CENTRE
OF PIT WHEN IN USE
X-127
FINAL SUBMITTAL
C044138No.RE G I
S T
ER
ED PR O FE S S I ON A L E NG I NEER
S TA T E O F C A L I F O R N I A
50m
1:500
NOTES:
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH PAF180500 RAAF
TINDAL HAZARDOUS AREA AND EXPLOSIVE AREA CLASSIFICATION
REPORT.
2. AIRCRAFT SHOWN FOR ILLUSTRATIVE PURPOSES ONLY. REFER TO
DRAWING X-117 and X-118 FOR THE EO HAZARDOUS AREA ZONES FOR
EO HANDLING ON THE APRON.
HAZARDOUS AREA ZONE BOUNDARIES:
ZONE 1 - EPL Gb
AN AREA IN WHICH AN EXPLOSIVE GAS ATMOSPHERE IS
LIKELY TO OCCUR OCCASIONALLY IN NORMAL OPERATION
ELECTRICAL EQUIPMENT &
TEMPERATURE CLASS:
ELECTRICAL APPARATUS INTENDED FOR INSTALLATION WITHIN THE ZONE 1
OR ZONE 2 HAZARDOUS AREAS DEPICTED ON THIS DRAWING, SHALL BE
IECEx CERTIFIED AS BEING SUITABLE FOR THE FOLLOWING:
GAS GROUP: IIA
TEMPERATURE CLASS: T3
AMBIENT TEMPERATURE RANGE: 0*C TO 45*C
CLASSIFICATION OF HAZARDOUS AREAS ACCORDING TO AS/NZS IEC
60079.10.1:2022
ZONE 2 - EPL Gc
AN AREA IN WHICH AN EXPLOSIVE GAS ATMOSPHERE IS
NOT LIKELY TO OCCUR IN NORMAL OPERATION BUT IF IT
DOES OCCUR IT WILL EXIST FOR A SHORT PERIOD ONLY
TN
PLAN
NORTH
A1HAZARDOUS AREA - MAIN APRON
SCALE: 1:500m
TAXIWAY A
NEW BOMBER APRON
C-17A Globemaster III
C-17A Globemaster III
PE
A330 MRTT
A330 MRTT
PE
B-52HB-52H
PE
C-17A Globemaster III
C-17A Globemaster III
PE
A330 MRTT
A330 MRTT
PE
B-52HB-52H
PE
C-17A Globemaster III
C-17A Globemaster III
PE
A330 MRTT
A330 MRTT
PE
B-52HB-52H
PE
W W W W W W W W W W W W W W W
W W
W W
W W
W W
B-52H B-52H B-52H B-52H B-52H B-52H
AGL
AGL
AGL
D25
AG
L
AGL
D7
AGL
D7
D7
AGL
AGL
AGL
AGL
AGL
AGL
AGL
AGL
AGL
D7
AG
C
C
C
C C
C C
C C
C
C
POL POL POL POL POL POL POL POL POL
PO
L
PO
L
PO
L
PO
L
PO
L
PO
L
POLPOLPOLPOLPOLPOLPOLPOLPOL
ZONE 1 WITHIN PIPES
AND BOX CULVERTS
ZONE 1 WITHIN EXTENTS
OF PITS AND DRAINS
ISOLATION VALVE PIT
ZONE 1 WITHIN
EXTENTS OF PITZONE 2 R=1.5m FROM CENTRE OF PIT
WHEN IN USE
HYDRANT
OUTLET PIT
ZONE 2 R=1.5m
FROM CENTRE
OF PIT WHEN
IN USE
ZONE 1 WITHIN
EXTENT OF PIT
ZONE 2 R=0.5m
HORIZONTALLY FROM
EDGE OF GRATING AND
TO 3.0m ABOVE GRATING
ZONE 1 R=1.0m FROM
CENTRE OF PIT WHEN
IN USE
ZONE 2 R=1.5m FROM
CENTRE OF PIT
WHEN IN USE
ZONE 1 WITHIN
EXTENT OF PIT
ZONE 1 R=1.0m FROM
CENTRE OF PIT WHEN
IN USE
ZONE 2 R=1.5m
FROM CENTRE OF
PIT WHEN IN USE
ZONE 1 WITHIN
EXTENT OF PIT
ZONE 1 R=1.0m FROM
CENTRE OF PIT WHEN
IN USE
ZONE 1 R=1.0m FROM CENTRE OF PIT
WHEN IN USE
C3 X-501
HYDRANT
OUTLET PIT
HYDRANT
OUTLET PIT
C1 X-502
C2 X-502
C1 X-502
C2 X-502
C1 X-502
C2 X-502
FINAL SUBMITTAL
C044138No.RE G I
S T
ER
ED PR O FE S S I ON A L E NG I NEER
S TA T E O F C A L I F O R N I A
50m
1:500
TN
PLAN
NORTH
A1HAZARDOUS AREA - MAIN APRON
SCALE: 1:500m X-128
NOTES:
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH PAF180500 RAAF
TINDAL HAZARDOUS AREA AND EXPLOSIVE AREA CLASSIFICATION
REPORT.
2. AIRCRAFT SHOWN FOR ILLUSTRATIVE PURPOSES ONLY. REFER TO
DRAWING X-117 and X-118 FOR THE EO HAZARDOUS AREA ZONES FOR
EO HANDLING ON THE APRON.
HAZARDOUS AREA ZONE BOUNDARIES:
ELECTRICAL EQUIPMENT&
TEMPERATURE CLASS:
ELECTRICAL APPARATUS INTENDED FOR INSTALLATION WITHIN THE ZONE 1
OR ZONE 2 HAZARDOUS AREAS DEPICTED ON THIS DRAWING, SHALL BE
IECEx CERTIFIED AS BEING SUITABLE FOR THE FOLLOWING:
GAS GROUP: IIA
TEMPERATURE CLASS: T3
AMBIENT TEMPERATURE RANGE: 0*C TO 45*C
CLASSIFICATION OF HAZARDOUS AREAS ACCORDING TO AS/NZS IEC
60079.10.1:2022
ZONE 2 - EPL Gc
AN AREA IN WHICH AN EXPLOSIVE GAS ATMOSPHERE IS
NOT LIKELY TO OCCUR IN NORMAL OPERATION BUT IF IT
DOES OCCUR IT WILL EXIST FOR A SHORT PERIOD ONLY
ZONE 1 - EPL Gb
AN AREA IN WHICH AN EXPLOSIVE GAS ATMOSPHERE IS
LIKELY TO OCCUR OCCASIONALLY IN NORMAL OPERATION
TAXIWAY A
NEW BOMBER APRON
AC
CE
SS
R
OA
D
BAR GRATING
FINISH GRADE
WALL PENETRATION
(TYP)
DN50
HPV
DN250
FULL PORT
DN250 HYDRANT
LOOP RETURN TO
FILTER BUILDING
DN50 LPD
DN50
HPV
IF
DN250 HYDRANT
LOOP RETURN
FROM B-52 APRON
IF
DN250
ZONE 1 INSIDE PIT
PIT SUMP
APPROXIMATE ROLLING
PIT COVER BOUNDARY
DN250 HYDRANT
LOOP RETURN TO
FILTER BUILDING
LADDER
EXISTING VALVE PIT
D
N
DN250
WALL PENETRATION,
(TYP OF 2)
DN250 HYDRANT
LOOP ISSUE FROM
FILTER BUILDING
DN250
DN25 DOUBLE
CHECK VALVE
RELIEF ASSEMBLY
(TYP OF 2)
DN250 HYDRANT
LOOP RETURN
FROM B-52 APRON
DN50 LPD
DN250 HYDRANT
LOOP ISSUE TO
B-52 APRON
DN50 HPV
IF
IF IF
IF
HPV/LPD
SUPPORT
DN250 HYDRANT LOOP RETURN TO FILTER BUILDING
ZONE 1 INSIDE PIT
ZONE 1 INSIDE PIT
A3
ZONE 1 INSIDE PIT
X-501 3000mm
1:30
15000
FINAL SUBMITTAL
C044138No.RE G I
S T
ER
ED PR O FE S S I ON A L E NG I NEER
S TA T E O F C A L I F O R N I A
NOTES:
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH PAF180500 RAAF
TINDAL HAZARDOUS AREA AND EXPLOSIVE AREA CLASSIFICATION
REPORT.
2. THE ZONE EXTENTS ARE NOT VALID WHEN A DRAIN / SCOUR HOSE IS
CONNECTED TO THE LOW POINT DRAIN OR HIGH POINT VENT. WHEN A
HOSE IS CONNECTED TO THE DRAIN OR VENT COUPLINGS, AND FOR
FIVE MINUTES AFTER THE HOSE IS REMOVED, THEN THE HAZARDOUS
AREA ZONE EXTENTS WILL BE THE SAME AS THE FUEL HYDRANT
OUTLET WITH A HOSE CONNECTED.
HAZARDOUS AREA ZONE BOUNDARIES:
ZONE 1 - EPL Gb
AN AREA IN WHICH AN EXPLOSIVE GAS ATMOSPHERE IS
LIKELY TO OCCASIONALLY OCCUR IN NORMAL OPERATION
ELECTRICAL EQUIPMENT &
TEMPERATURE CLASS:
ELECTRICAL APPARATUS INTENDED FOR INSTALLATION WITHIN THE
HAZARDOUS AREAS DEPICTED ON THIS DRAWING SHALL BE IECEx
CERTIFIED AS BEING SUITABLE FOR THE FOLLOWING:
- GAS GROUP: II A
- TEMPERATURE CLASS: T3
AMBIENT TEMPERATURE RANGE 0 TO 45 DEGREES CELSIUS
CLASSIFICATION OF HAZARDOUS AREAS ACCORDING TO AS/NZS IEC
60079.10.1:2022
ZONE 2 - EPL Gc
AN AREA IN WHICH AN EXPLOSIVE GAS ATMOSPHERE IS
NOT LIKELY TO OCCUR IN NORMAL OPERATION BUT IF IT
DOES OCCUR IT WILL EXIST FOR A SHORT PERIOD ONLY
C1HYDRANT LOOP CROSSOVER PIT PIPING PLAN (NOTE 2)
SCALE: 1:30
A1HYDRANT LOOP CROSSOVER PIT PIPING SECTION (NOTE 2)
-SCALE: 1:30
A1
C3ISOLATION VALVE PIT PIPING PLAN (NOTE 2)
X-128SCALE: 1:20
A3ISOLATION VALVE PIT PIPING SECTION (NOTE 2)
-SCALE: 1:20
2000mm
1:20
10000
X-502 1500mm750
1:15
FINAL SUBMITTAL
C044138No.RE G I
S T
ER
ED PR O FE S S I ON A L E NG I NEER
S TA T E O F C A L I F O R N I A
NOTES:
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH PAF180500 RAAF
TINDAL HAZARDOUS AREA AND EXPLOSIVE AREA CLASSIFICATION
REPORT.
HAZARDOUS AREA ZONE BOUNDARIES:
ELECTRICAL EQUIPMENT &
TEMPERATURE CLASS:
A2AND FOR FIVE MINUTES AFTER HOSES ARE DISCONNECTED
-SCALE: 1:15
HYDRANT OUTLET PIT SECTION - WHEN HOSE CONNECTED
FUEL HOSE TO
HYDRANT TRUCK
ZONE 1 INSIDE PIT
ZONE 1 - EPL Gb
AN AREA IN WHICH AN EXPLOSIVE GAS ATMOSPHERE IS
LIKELY TO OCCASIONALLY OCCUR IN NORMAL OPERATION
ELECTRICAL APPARATUS INTENDED FOR INSTALLATION WITHIN THE
HAZARDOUS AREAS DEPICTED ON THIS DRAWING SHALL BE IECEx
CERTIFIED AS BEING SUITABLE FOR THE FOLLOWING:
- GAS GROUP: II A
- TEMPERATURE CLASS: T3
AMBIENT TEMPERATURE RANGE 0 TO 45 DEGREES CELSIUS
CLASSIFICATION OF HAZARDOUS AREAS ACCORDING TO AS/NZS IEC
60079.10.1:2022
ZONE 2 - EPL Gc
AN AREA IN WHICH AN EXPLOSIVE GAS ATMOSPHERE IS
NOT LIKELY TO OCCUR IN NORMAL OPERATION BUT IF IT
DOES OCCUR IT WILL EXIST FOR A SHORT PERIOD ONLY
ZONE 2 R=1.5m FROM HOSE CONNECTION
ZONE 1 R=1.0m FROM HOSE CONNECTION
C2AND FOR FIVE MINUTES AFTER HOSES ARE DISCONNECTED
-SCALE: 1:15
HYDRANT OUTLET PIT PLAN - WHEN HOSE CONNECTED
A2
FUEL HOSE TO HYDRANT TRUCK
C1HYDRANT OUTLET PIT PLAN - WHEN NOT IN USE
X-127, X-128SCALE: 1:15
A1HYDRANT OUTLET PIT SECTION - WHEN NOT IN USE
X-127, X-128SCALE: 1:15
A1
ZONE 1 INSIDE PIT
ZONE 2 R=1.5m FROM HOSE CONNECTION
ZONE 1 R=1.0m FROM HOSE CONNECTION
ZONE 1 INSIDE PIT
ZONE 1 INSIDE PIT
ZONE 1 INSIDE PIT
ZONE 1 INSIDE PIT
ZONE 1 INSIDE PIT
X-503
FINAL SUBMITTAL
C044138No.RE G I
S T
ER
ED PR O FE S S I ON A L E NG I NEER
S TA T E O F C A L I F O R N I A
B1LOW POINT DRAIN PIT - PAVED AREAS (NOTE 2)
X-127SCALE: 1:20 B3HIGH POINT VENT PIT - PAVED AREAS (NOTE 2)
X-127SCALE: 1:20
D1DOUBLE LOW POINT DRAIN PIT - UNPAVED AREAS (NOTE 2)
X-127SCALE: 1:20 D3DOUBLE HIGH POINT VENT PIT - UNPAVED AREAS (NOTE 2)
-SCALE: 1:20
2000mm
1:20
10000
NOTES:
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH PAF180500 RAAF
TINDAL HAZARDOUS AREA AND EXPLOSIVE AREA CLASSIFICATION
REPORT.
2. THE ZONE EXTENTS ARE NOT VALID WHEN A DRAIN / SCOUR HOSE IS
CONNECTED TO THE LOW POINT DRAIN OR HIGH POINT VENT. WHEN A
HOSE IS CONNECTED TO THE DRAIN OR VENT COUPLINGS, AND FOR
FIVE MINUTES AFTER THE HOSE IS REMOVED, THEN THE HAZARDOUS
AREA ZONE EXTENTS WILL BE THE SAME AS THE FUEL HYDRANT
OUTLET WITH A HOSE CONNECTED.
HAZARDOUS AREA ZONE BOUNDARIES:
ZONE 1 - EPL Gb
AN AREA IN WHICH AN EXPLOSIVE GAS ATMOSPHERE IS
LIKELY TO OCCASIONALLY OCCUR IN NORMAL OPERATION
ELECTRICAL EQUIPMENT &
TEMPERATURE CLASS:
ELECTRICAL APPARATUS INTENDED FOR INSTALLATION WITHIN THE
HAZARDOUS AREAS DEPICTED ON THIS DRAWING SHALL BE IECEx
CERTIFIED AS BEING SUITABLE FOR THE FOLLOWING:
- GAS GROUP: II A
- TEMPERATURE CLASS: T3
AMBIENT TEMPERATURE RANGE 0 TO 45 DEGREES CELSIUS
CLASSIFICATION OF HAZARDOUS AREAS ACCORDING TO AS/NZS IEC
60079.10.1:2022
ZONE 2 - EPL Gc
AN AREA IN WHICH AN EXPLOSIVE GAS ATMOSPHERE IS
NOT LIKELY TO OCCUR IN NORMAL OPERATION BUT IF IT
DOES OCCUR IT WILL EXIST FOR A SHORT PERIOD ONLY
W W
X-504
A1HAZARDOUS AREA PLAN
X-127SCALE: 1:100m
FINAL SUBMITTAL
C044138No.RE G I
S T
ER
ED PR O FE S S I ON A L E NG I NEER
S TA T E O F C A L I F O R N I A
10m
1:100
NOTES:
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH PAF180500 RAAF
TINDAL HAZARDOUS AREA AND EXPLOSIVE AREA CLASSIFICATION
REPORT.
HAZARDOUS AREA ZONE BOUNDARIES:
ELECTRICAL EQUIPMENT &
TEMPERATURE CLASS:
TN
PLAN
NORTH
ZONE 1 WITHIN
PIPE (TYPICAL)
ZONE 1 WITHIN PIT
ZONE 1
WITHIN SQID
ZONE 1 WITHIN PIT
ZONE 1 WITHIN PIT
ZONE 1 WITHIN DRAIN PIPE (TYPICAL)
ZONE 1 WITHIN GRATING
ZONE 1 WITHIN PIT
ZONE 2 R=0.5m
ZONE 1 WITHIN WEIR PIT
ZONE 1 WITHIN PIT
(TYPICAL)
ZONE 1 WITHIN DRAIN PIPE
(TYPICAL)
A4HAZARDOUS AREA PLAN
X-127SCALE: 1:100m
ZONE 1 WITHIN PIPE BYPASS PIT
ZONE 2 R=0.5m FROM
DISCHARGE PIPE OPENING
IN ALL DIRECTIONS
ZONE 1 WITHIN DISCHARGE PIPE
ZONE 1 - EPL Gb
AN AREA IN WHICH AN EXPLOSIVE GAS ATMOSPHERE IS
LIKELY TO OCCASIONALLY OCCUR IN NORMAL OPERATION
ELECTRICAL APPARATUS INTENDED FOR INSTALLATION WITHIN THE
HAZARDOUS AREAS DEPICTED ON THIS DRAWING SHALL BE IECEx
CERTIFIED AS BEING SUITABLE FOR THE FOLLOWING:
- GAS GROUP: II A
- TEMPERATURE CLASS: T3
AMBIENT TEMPERATURE RANGE 0 TO 45 DEGREES CELSIUS
CLASSIFICATION OF HAZARDOUS AREAS ACCORDING TO AS/NZS IEC
60079.10.1:2022
ZONE 2 - EPL Gc
AN AREA IN WHICH AN EXPLOSIVE GAS ATMOSPHERE IS
NOT LIKELY TO OCCUR IN NORMAL OPERATION BUT IF IT
DOES OCCUR IT WILL EXIST FOR A SHORT PERIOD ONLY
X-506 A1
X-506 A1
SQID PAD
0.
m
RCBC / RCP RCBC / RCP
GRATED DRAIN
INLET BEYOND
0.5m 0.5m
0.
3m
RCPRCP
RCBC
INLET
RCPRCP
0.5m 0.5m
0.
5m
0.5 m
0.5m
RC
BC
RC
P
RC
BC
RC
P
A1SECTION - TYPICAL FLAME TRAP
SCALE: 1:20mm
X-505
FINAL SUBMITTAL
C044138No.RE G I
S T
ER
ED PR O FE S S I ON A L E NG I NEER
S TA T E O F C A L I F O R N I A
PIT LID PROVIDES VAPOUR SEAL
ZONE 1 INSIDE GRATED DRAIN DOWN TO WATER LEVEL
FLAME TRAP
WATER LEVEL
ZONE 1 WITHIN PITS AND CHANNELS
DOWN TO WATER LEVEL
ZONE 2: 0.5m LATERALLY AND 0.3m ABOVE GRATES
FLAME TRAP
WATER LEVEL
FLAME TRAP
WATER LEVEL
PIT LID PROVIDES VAPOUR SEAL
ZONE 1 INSIDE STORMWATER
COLLECTION PIPES DOWN TO
WATER LEVEL
ZONE 1 INSIDE
GRATED DRAIN
ZONE 2: 0.5m LATERALLY AND 0.3m ABOVE GRATES
PAVEMENT AS SPECIFIED
2000mm
1:20
10000
C1PLAN - TYPICAL FLAME TRAP
X-127SCALE: 1:20mm
A1
A4
A4SECTION - TYPICAL FLAME TRAP
SCALE: 1:20mm
NOTES:
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH PAF180500 RAAF
TINDAL HAZARDOUS AREA AND EXPLOSIVE AREA CLASSIFICATION
REPORT.
HAZARDOUS AREA ZONE BOUNDARIES:
ELECTRICAL EQUIPMENT &
TEMPERATURE CLASS:
ZONE 1 WITHIN
CHANNELS
ZONE 1 - EPL Gb
AN AREA IN WHICH AN EXPLOSIVE GAS ATMOSPHERE IS
LIKELY TO OCCASIONALLY OCCUR IN NORMAL OPERATION
ELECTRICAL APPARATUS INTENDED FOR INSTALLATION WITHIN THE
HAZARDOUS AREAS DEPICTED ON THIS DRAWING SHALL BE IECEx
CERTIFIED AS BEING SUITABLE FOR THE FOLLOWING:
- GAS GROUP: II A
- TEMPERATURE CLASS: T3
AMBIENT TEMPERATURE RANGE 0 TO 45 DEGREES CELSIUS
CLASSIFICATION OF HAZARDOUS AREAS ACCORDING TO AS/NZS IEC
60079.10.1:2022
ZONE 2 - EPL Gc
AN AREA IN WHICH AN EXPLOSIVE GAS ATMOSPHERE IS
NOT LIKELY TO OCCUR IN NORMAL OPERATION BUT IF IT
DOES OCCUR IT WILL EXIST FOR A SHORT PERIOD ONLY
PAVEMENT AS SPECIFIED PAVEMENT AS SPECIFIED
X-506 2000mm
1:20
10000
FINAL SUBMITTAL
C044138No.RE G I
S T
ER
ED PR O FE S S I ON A L E NG I NEER
S TA T E O F C A L I F O R N I A
A1HAZARDOUS AREA SECTION
X-504SCALE: 1:20mm
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH PAF180500 RAAF
TINDAL HAZARDOUS AREA AND EXPLOSIVE AREA CLASSIFICATION
REPORT.
ZONE 1 - EPL Gb
AN AREA IN WHICH AN EXPLOSIVE GAS ATMOSPHERE IS
LIKELY TO OCCASIONALLY OCCUR IN NORMAL OPERATION
ELECTRICAL APPARATUS INTENDED FOR INSTALLATION WITHIN THE
HAZARDOUS AREAS DEPICTED ON THIS DRAWING SHALL BE IECEx
CERTIFIED AS BEING SUITABLE FOR THE FOLLOWING:
- GAS GROUP: II A
- TEMPERATURE CLASS: T3
AMBIENT TEMPERATURE RANGE 0 TO 45 DEGREES CELSIUS
CLASSIFICATION OF HAZARDOUS AREAS ACCORDING TO AS/NZS IEC
60079.10.1:2022
ZONE 2 - EPL Gc
AN AREA IN WHICH AN EXPLOSIVE GAS ATMOSPHERE IS
NOT LIKELY TO OCCUR IN NORMAL OPERATION BUT IF IT
DOES OCCUR IT WILL EXIST FOR A SHORT PERIOD ONLY
NOTES:
ELECTRICAL EQUIPMENT &
TEMPERATURE CLASS:
HAZARDOUS AREA ZONE BOUNDARIES:
ZONE 1 WITHIN PENSTOCK PIT
R3.0m
R3.0m
R1 .0m
FLEXIBLE HOSE
ZONE 2 R=3.0m FROM
FUEL TANK VENTS
(NOTE 2)
ZONE 2 R=3.0m FROM
FUEL TANK VENTS
(NOTE 2)
HYDRANT PIT
ZONE 2 R=1.5m FROM FUEL HOSE CONNECTIONS
ZONE 1 R=1.0m FROM FUEL HOSE CONNECTIONS
FUEL TRANSFER TRUCK
ZONE 2 R=3.0m FROM DEFUELING PUMP
WHEN DEFUELING (NOTE 4)
ZONE 2 1.5m FROM FUEL TRANSFER TRUCK
ZONE 1 R=1.0m FROM DEFUELING PUMP
WHEN DEFUELING
3.0m 3.0m
3.0m3.0m
1.
5m
ZONE 2 R=3.0m FROM FUEL TANK VENTS
(NOTE 2)
1.
5m
ZONE 2 R=3.0m FROM
FUEL HOSE CONNECTION
ZONE 1 R=1.0m
ZONE 2 R=3.0m FROM
FUEL TANK VENTS (NOTE 2)
3.0m 3.0m
1.
5m
1.
5m
1.5mZONE 2 1.5m FROM FUEL TRANSFER TRUCK
ZONE 2 R=1.5m FROM FUEL HOSE CONNECTION
ZONE 1 R=1.0m FROM FUEL HOSE CONNECTION
X-520 20000mm
1:200
100000
FINAL SUBMITTAL
C044138No.RE G I
S T
ER
ED PR O FE S S I ON A L E NG I NEER
S TA T E O F C A L I F O R N I A
NOTES:
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH PAF180500 RAAF
TINDAL HAZARDOUS AREA AND EXPLOSIVE AREA CLASSIFICATION
REPORT.
2. LOCATION OF FUEL TANK VENTS ARE NOT CONFIRMED. THE
HAZARDOUS AREAS ASSOCIATED WITH THE FUEL TANK VENT SHOULD
BE LOCATED AT THE ACTUAL LOCATION OF THE FUEL TANK VENT(S)
3. THIS DETAIL DOES NOT SHOW EO HAZARDOUS AREAS FOR PARKING
POSITIONS 1 AND 6. REFER TO DRAWINGS X-117 AND X-118.
4. THIS ZONE 2 IS WHOLLY ENCLOSED WITHIN THE ZONE 2 ASSIGNED TO
THE FUEL TRANSFER TRUCK AND IS MARKED FOR INFORMATION ONLY
HAZARDOUS AREA ZONE BOUNDARIES:
ELECTRICAL EQUIPMENT &
TEMPERATURE CLASS:
A1B-52 AIRCRAFT REFUELLING PLAN
-SCALE: 1:200m A3B-52 AIRCRAFT REFUELLING ELEVATION
-SCALE: 1:200m
ZONE 1 - EPL Gb
AN AREA IN WHICH AN EXPLOSIVE GAS ATMOSPHERE IS
LIKELY TO OCCASIONALLY OCCUR IN NORMAL OPERATION
ELECTRICAL APPARATUS INTENDED FOR INSTALLATION WITHIN THE
HAZARDOUS AREAS DEPICTED ON THIS DRAWING SHALL BE IECEx
CERTIFIED AS BEING SUITABLE FOR THE FOLLOWING:
- GAS GROUP: II A
- TEMPERATURE CLASS: T3
AMBIENT TEMPERATURE RANGE 0 TO 45 DEGREES CELSIUS
CLASSIFICATION OF HAZARDOUS AREAS ACCORDING TO AS/NZS IEC
60079.10.1:2022
ZONE 2 - EPL Gc
AN AREA IN WHICH AN EXPLOSIVE GAS ATMOSPHERE IS
NOT LIKELY TO OCCUR IN NORMAL OPERATION BUT IF IT
DOES OCCUR IT WILL EXIST FOR A SHORT PERIOD ONLY
ZONE 2 R=3.0m FROM
FUEL TANK VENTS
(NOTE 2)
R3.0m
ZONE 2 R=3.0m FROM
FUEL TANK VENTS
(NOTE 2)
ZONE 2 R=3.0m FROM
FUEL TANK CONNECTION
ZONE 1 R=1.0m FROM
FUEL TANK CONNECTION
FLEXIBLE HOSE
HYDRANT PIT
ZONE 2 R=1.5m FROM FUEL HOSE CONNECTIONS
ZONE 1 R=1.0m FROM FUEL HOSE CONNECTIONS
FUEL TRANSFER TRUCK
ZONE 2 R=3.0m FROM DEFUELING PUMP WHEN DEFUELING (NOTE 4)
ZONE 2 1.5m FROM FUEL TRANSFER TRUCK
ZONE 1 R=1.0m FROM DEFUELING PUMP WHEN DEFUELING
ZONE 2 R=3.0m FROM FUEL TANK VENT 3.0m
1.
5m
ZONE 2 R=3.0m FROM FUEL TANK VENT
3.0m3.0m
1.
5m
1.
5m
1.5mZONE 2 1.5m FROM FUEL TRANSFER TRUCK
ZONE 2 R=1.5m FROM FUEL HOSE CONNECTIONS
ZONE 1 R=1.0m FROM FUEL HOSE CONNECTIONS
ZONE 1 R=1.0m FROM FUEL HOSE CONNECTIONS ZONE 2 R=1.5m FROM FUEL HOSE CONNECTIONS
3.0m 3.0m
X-521 20000mm
1:200
100000
FINAL SUBMITTAL
C044138No.RE G I
S T
ER
ED PR O FE S S I ON A L E NG I NEER
S TA T E O F C A L I F O R N I A
NOTES:
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH PAF180500 RAAF
TINDAL HAZARDOUS AREA AND EXPLOSIVE AREA CLASSIFICATION
REPORT.
2. LOCATION OF FUEL TANK VENTS ARE NOT CONFIRMED. THE
HAZARDOUS AREAS ASSOCIATED WITH THE FUEL TANK VENT SHOULD
BE LOCATED AT THE ACTUAL LOCATION OF THE FUEL TANK VENT(S)
3. THIS DETAIL DOES NOT SHOW EO HAZARDOUS AREAS FOR PARKING
POSITIONS 1 AND 6. REFER TO DRAWINGS X-117 AND X-118.
4. THIS ZONE 2 IS WHOLLY ENCLOSED WITHIN THE ZONE 2 ASSIGNED TO
THE FUEL TRANSFER TRUCK AND IS MARKED FOR INFORMATION ONLY
HAZARDOUS AREA ZONE BOUNDARIES:
ELECTRICAL EQUIPMENT &
TEMPERATURE CLASS:
A1C-17A AIRCRAFT REFUELLING PLAN
-SCALE: 1:200m A3C-17A AIRCRAFT REFUELLING ELEVATION
-SCALE: 1:200m
ZONE 1 - EPL Gb
AN AREA IN WHICH AN EXPLOSIVE GAS ATMOSPHERE IS
LIKELY TO OCCASIONALLY OCCUR IN NORMAL OPERATION
ELECTRICAL APPARATUS INTENDED FOR INSTALLATION WITHIN THE
HAZARDOUS AREAS DEPICTED ON THIS DRAWING SHALL BE IECEx
CERTIFIED AS BEING SUITABLE FOR THE FOLLOWING:
- GAS GROUP: II A
- TEMPERATURE CLASS: T3
AMBIENT TEMPERATURE RANGE 0 TO 45 DEGREES CELSIUS
CLASSIFICATION OF HAZARDOUS AREAS ACCORDING TO AS/NZS IEC
60079.10.1:2022
ZONE 2 - EPL Gc
AN AREA IN WHICH AN EXPLOSIVE GAS ATMOSPHERE IS
NOT LIKELY TO OCCUR IN NORMAL OPERATION BUT IF IT
DOES OCCUR IT WILL EXIST FOR A SHORT PERIOD ONLY
A330-200A3
-2
R3.0m ZONE 2 R=3.0m FROM
FUEL TANK VENTS
(NOTE 2)
ZONE 2 R=3.0m FROM
FUEL TANK VENTS
(NOTE 2)
ZONE 1 R=1.0m FROM
FUEL TANK CONNECTION
(UNDER WING)
ZONE 2 R=3.0m FROM
FUEL TANK CONNECTION
(UNDER WING)
R3.0m
HYDRANT PITFLEXIBLE HOSE
ZONE 2 R=1.5m FROM FUEL HOSE CONNECTIONS
ZONE 1 R=1.0m FROM FUEL HOSE CONNECTIONS
ZONE 1 R=1.0m FROM
FUEL TANK CONNECTION
(UNDER WING)
ZONE 2 R=3.0m FROM
FUEL TANK CONNECTION
(UNDER WING)
FUEL TRANSFER TRUCK
ZONE 2 R=3.0m FROM DEFUELING PUMP
WHEN DEFUELING (NOTE 4)
ZONE 2 1.5m FROM FUEL TRANSFER TRUCK
ZONE 1 R=1.0m FROM DEFUELING PUMP
WHEN DEFUELING
ZONE 2 R=3.0m FROM
FUEL TANK VENTS
(NOTE 2)R3.0m
ZONE 2 R=3.0m FROM
FUEL TANK VENT
3.0m
1.
5m
1.
5m
1.5m ZONE 2 1.5m FROM FUEL TRANSFER TRUCK ZONE 2 R=1.5m FROM FUEL HOSE CONNECTIONS
ZONE 1 R=1.0m FROM FUEL HOSE CONNECTIONS
6.0m
ZONE 2 R=3.0m
FROM FUEL TANK VENT
3.0m
1.
5m
ZONE 1 R=1.0m FROM FUEL TANK CONNECTION
(UNDER WING)
ZONE 2 R=3.0m FROM FUEL TANK CONNECTION
(UNDER WING)
ZONE 2 R=3.0m FROM FUEL TANK VENTS
(NOTE 2)
1.
5mZONE 1 R=1.0m FROM FUEL HOSE CONNECTION
ZONE 2 R=3.0m FROM FUEL HOSE CONNECTION
X-522 20000mm
1:200
100000
FINAL SUBMITTAL
C044138No.RE G I
S T
ER
ED PR O FE S S I ON A L E NG I NEER
S TA T E O F C A L I F O R N I A
NOTES:
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH PAF180500 RAAF
TINDAL HAZARDOUS AREA AND EXPLOSIVE AREA CLASSIFICATION
REPORT.
2. LOCATION OF FUEL TANK VENTS ARE NOT CONFIRMED. THE
HAZARDOUS AREAS ASSOCIATED WITH THE FUEL TANK VENT SHOULD
BE LOCATED AT THE ACTUAL LOCATION OF THE FUEL TANK VENT(S)
3. THIS DETAIL DOES NOT SHOW EO HAZARDOUS AREAS FOR PARKING
POSITIONS 1 AND 6. REFER TO DRAWINGS X-117 AND X-118.
4. THIS ZONE 2 IS WHOLLY ENCLOSED WITHIN THE ZONE 2 ASSIGNED TO
THE FUEL TRANSFER TRUCK AND IS MARKED FOR INFORMATION ONLY
HAZARDOUS AREA ZONE BOUNDARIES:
ELECTRICAL EQUIPMENT &
TEMPERATURE CLASS:
A1KC-30A AIRCRAFT REFUELLING PLAN
-SCALE: 1:200m A3KC-30A AIRCRAFT REFUELLING ELEVATION
-SCALE: 1:200m
ZONE 1 - EPL Gb
AN AREA IN WHICH AN EXPLOSIVE GAS ATMOSPHERE IS
LIKELY TO OCCASIONALLY OCCUR IN NORMAL OPERATION
ELECTRICAL APPARATUS INTENDED FOR INSTALLATION WITHIN THE
HAZARDOUS AREAS DEPICTED ON THIS DRAWING SHALL BE IECEx
CERTIFIED AS BEING SUITABLE FOR THE FOLLOWING:
- GAS GROUP: II A
- TEMPERATURE CLASS: T3
AMBIENT TEMPERATURE RANGE 0 TO 45 DEGREES CELSIUS
CLASSIFICATION OF HAZARDOUS AREAS ACCORDING TO AS/NZS IEC
60079.10.1:2022
ZONE 2 - EPL Gc
AN AREA IN WHICH AN EXPLOSIVE GAS ATMOSPHERE IS
NOT LIKELY TO OCCUR IN NORMAL OPERATION BUT IF IT
DOES OCCUR IT WILL EXIST FOR A SHORT PERIOD ONLY
GENERAL MECHANICAL (POL) NOTES .
1. MECHANICAL POL PIPING WORK MUST BE IN ACCORDANCE WITH ASME B31.3 UNLESS
OTHERWISE INDICATED.
2. WELDS ON STAINLESS STEEL PIPING MUST BE BY THE GTAW PROCESS FOR ROOT AND FILL
PASSES AS INDICATED.
3. COORDINATE DRAIN-DOWN OF EXISTING PIPING WITH RAAF BASE TINDAL TO MINIMIZE FUEL
SYSTEM DOWNTIME. THE CONTRACTOR IS RESPONSIBLE FOR DRAIN-DOWN OF EXISTING
PIPING SYSTEMS AS REQUIRED TO PERFORM THE WORK UNDER THIS PROJECT AND MUST
RETURN FUEL REMOVED FROM EXISTING PIPING TO RAAF BASE TINDAL.
4. DEFINITIONS
A. PURGING: THE COMPLETE REMOVAL OF FUEL FROM PIPING BY USING VACUUM EQUIPMENT
TO REMOVE FUEL AT LOW POINTS, AND/OR COLD CUTTING PIPING AT LOW POINTS TO DRAIN
FUEL.
B. INERTING: THE REMOVAL OR NEUTRALIZATION OF EXPLOSIVE VAPORS IN PIPE OR
PORTIONS OF PIPE WHICH PREVIOUSLY CONTAINED FUEL AS REQUIRED TO PERFORM HOT
WORK.
C. DEMOLISH: REMOVE AND DISPOSE OF OFF SITE.
5. AFTER DEFUELING, THE PIPING MUST BE PURGED AND INERTED AS REQUIRED TO MAKE TIE-IN
WELDS AND PERFORM HOT WORK SAFELY.
6. COLD CUTTING OF EXISTING PIPE IS REQUIRED AFTER DEFUELING. PERFORM THE INITIAL
CUTTING OF THE EXISTING PIPING WITH A MULTI-WHEEL PIPE CUTTER USING NON-FLAMMABLE
LUBRICANT.
7. PROVIDE BLOCKING WHEN REMOVING COMPONENTS TO MAINTAIN PIPE AND FLANGE BOLT
ALIGNMENT.
8. EXISTING PIPING TO REMAIN MUST NOT BE DAMAGED DURING DEMOLITION AND REMOVAL
ACTIVITIES. DAMAGE TO EXISTING PIPE, SUPPORTS, VALVES, AND PIPE COATINGS MUST BE
REPAIRED AT NO ADDITIONAL EXPENSE TO THE GOVERNMENT.
9. PROVIDE MATING FLANGES AND GASKETS TO MATCH EXISTING WHERE REQUIRED.
10.FIELD VERIFY DIMENSIONS PRIOR TO FABRICATION OF PIPE. COORDINATE PIPE LENGTHS AND
ELEVATIONS WITH MECHANICAL EQUIPMENT PROVIDED, INCLUDING BUT NOT LIMITED TO,
PUMPS, FILTER SEPARATORS, STRAINERS, ETC.
11.PROVIDE LABELS FOR PIPING IN PITS. FOR PIPE SIGNAGE DETAIL, SEE A2/MP501.
12.PROJECT PAF180200 - APR JET FUEL STORAGE TANKS WAS A SEPARATE CONTRACT THAT
PROVIDED THE TYPE III HYDRANT SYSTEM, EXCEPT THE HYDRANT LOOP. PAF180200
GENERALLY FOLLOWED THE US STANDARD DESIGN AW 078-24-28 PRESSURIZED HYDRANT
FUELING SYSTEM, TYPE III (MARCH 2020). THE FOLLOWING FUELS ITEMS WERE PROVIDED
UNDER PAF180200.
A. TWO CUT AND COVER STORAGE TANKS EQUIPPED WITH FOUR 2,280 LPM VERTICAL TURBINE
FUEL PUMPS.
B. FILTER BUILDING EQUIPPED WITH TYPICAL TYPE III HYDRANT SYSTEM FEATURES SUCH AS
TWO 4,560 LPM RECEIPT FILTER/SEPARATORS, FOUR 2,280 LPM ISSUE FILTER/SEPARATOR
VESSELS, ISSUE AND RETURN VENTURIS AND CONTROLS EQUIPMENT, SURGE
SUPPRESSORS, BACKPRESSURE CONTROL VALVE, DEFUEL/FLUSH VALVE, PRESSURE
CONTROL VALVE, PIG LAUNCHER AND RECEIVER FOR THE HYDRANT LOOP, AND CONTROLS
ROOM WITH PUMP CONTROL PANEL AND MOTOR CONTROL CENTER.
C. EMERGENCY BACKUP GENERATOR.
D. PIPING BETWEEN THE FILTER BUILDING AND THE TRANSFER PIT TO/FROM THE KC-30A FUEL
SYSTEM.
E. GANTRY WITH DROP TANK FOR TRUCK OFFLOAD, SINGLE POSITION TRUCK FILLSTAND, AND
HYDRANT HOSE TRUCK CHECKOUT STATION.
F. PIPING BETWEEN THE FILTER BUILDING AND THE HYDRANT LOOP CROSSOVER VALVE PIT
INCLUDING CONNECTIONS TO THE GANTRY.
G. HYDRANT LOOP CROSSOVER VALVE PIT.
H. PRODUCT RECOVERY TANK AND WASTE TANK.
I. REFER TO DESIGN AND AS-BUILT DRAWINGS, AND FIELD VERIFY.
13.USE THE EXISTING SYSTEM PROVIDED UNDER PAF180200 TO FUNCTIONALLY TEST THE
HYDRANT LOOP.
FINAL SUBMITTAL
REENIGNELANOISSEFORPDERETSIGER DUNCAN KEITH
ME-1050291/24/23
DEFUELING AND FLUSHING SEQUENCE OF OPERATIONS .
DEFUELING
THIS OPERATIONAL SEQUENCE IS PROVIDED FOR INFORMATION ONLY AND WILL ONLY BE UTILIZED
UPON EXPLICIT APPROVAL FROM FSB AND RAAF TINDAL AND ONLY AFTER DEVELOPMENT OF
STANDARD OPERATING PROCEDURES BY THE SAME. RECOMMEND DEFUELING AIRCRAFT WHEN
THERE ARE NO OTHER AIRCRAFT CONNECTED TO THE HYDRANT LOOP AND PERFORMING A
FLUSHING OPERATION AFTER DEFUELING IS COMPLETE.
1. ALIGN SYSTEM VALVES FOR HYDRANT LOOP OPERATION.
NOTE: ALIGN RETURN VALVES IN THE PUMPHOUSE TO ALLOW FUEL TO FLOW THROUGH THE
BACKPRESSURE CONTROL VALVE (BPCV) AND RETURN TO THE ISSUE TANK.
2. SELECT THE OPERATING HYDRANT LOOP ON THE PERSONAL COMPUTER ("USAF LOOP", "RAAF
LOOP", OR "COMBINED USAF/RAAF LOOP").
3. SELECT THE DESIGNATED FUEL OPERATION BY SETTING THE "MODE SELECT" HAND SWITCH ON
THE PUMP CONTROL PANEL (PCP) TO "AUTO" OR "FLUSH".
4. AT THE HYDRANT OUTLET PIT, CONNECT THE R-12 HYDRANT HOSE TRUCK (HHT) TO AN
AIRCRAFT AND TO THE HYDRANT OUTLET PIT VALVE.
5. UTILIZE THE ON-BOARD DEFUEL PUMP TO DEFUEL THE AIRCRAFT. THE R-12 ON-BOARD PUMP IS CAPABLE OF DELIVERING 1,140 LPM AT 1,140 kPa.
6. IF THE SYSTEM IS IN "AUTO" AND HYDRANT PUMPS ARE ON, THE FUEL BEING REMOVED FROM
THE AIRCRAFT WILL EITHER GO INTO THE OTHER AIRCRAFT CONNECTED TO THE SYSTEM OR
WILL MODULATE THE BPCV OPEN TO RETURN FUEL TO OPERATING TANK.
A. THE BACK PRESSURE CONTROL VALVE (BPCV) SOLENOID WILL BE ENERGIZED TO ENABLE
THE BPCV TO MODULATE.
B. THE DEFUEL/FLUSH VALVE (D/FV) SOLENOID “A” WILL BE DE-ENERGIZED AND SOLENOID “B”
WILL BE DE-ENERGIZED TO CLOSE THE D/FV.
C. THE PRESSURE CONTROL VALVE (PCV) SOLENOID WILL BE ENERGIZED TO CLOSE THE VALVE.
7. IF THE SYSTEM IS IN "AUTO" AND HYDRANT PUMPS ARE OFF, THE FUEL BEING REMOVED FROM
THE AIRCRAFT WILL MODULATE BOTH PCV AND D/FV TO ALLOW FUEL TO PASS TO THE
OPERATING TANK.
A. THE BACK PRESSURE CONTROL VALVE (BPCV) SOLENOID WILL BE DE-ENERGIZED TO CLOSE
THE BPCV.
B. THE DEFUEL/FLUSH VALVE (D/FV) SOLENOID "A" WILL BE ENERGIZED AND SOLENOID “B” WILL
BE DE-ENERGIZED TO ENABLE THE D/FV TO MODULATE.
C. THE PRESSURE CONTROL VALVE (PCV) SOLENOID WILL BE DE-ENERGIZED TO ENABLE THE
PCV.
8. IF THE SYSTEM IS IN "FLUSH", THE FUEL BEING REMOVED FROM THE AIRCRAFT WILL PASS
THROUGH THE DEFUEL/FLUSH VALVE AND RETURN TO THE OPERATING TANK.
A. THE BACK PRESSURE CONTROL VALVE (BCPV) SOLENOID WILL BE DE-ENERGIZED TO CLOSE
THE BPCV.
B. THE DEFUEL/FLUSH VALVE (D/FV) SOLENOID "A" WILL BE DE-ENERGIZED AND SOLENOID "B"
WILL BE ENERGIZED TO OPEN THE D/FV.
C. THE PRESSURE CONTROL VALVE (PCV) SOLENOID WILL BE DE-ENERGIZED TO ENABLE THE
PCV WITH THE PUMPS ARE OFF. THE PRESSURE CONTROL VALVE (PCV) SOLENOID WILL BE
ENERGIZED TO CLOSE THE PCV WHEN THE PUMPS AR ON.
FLUSHING
IF THE SYSTEM HAS NOT BEEN USED FOR SEVERAL DAYS OR IF FUEL SAMPLES INDICATE THE
PRESENCE OF WATER OR EXCESSIVE SEDIMENT, THE FLUSHING PROCEDURE WILL BE AS
INDICATED:
1. ALIGN SYSTEM VALVES FOR HYDRANT LOOP OPERATION.
NOTE: ALIGN RETURN VALVES TO ALLOW FUEL TO FLOW THROUGH THE DEFUEL/FLUSH
VALVE (D/FV) AND RETURN TO THE ISSUE TANK THROUGH THE RECEIPT
FILTER/SEPARATORS.
2. SELECT THE OPERATING HYDRANT LOOP ON THE PERSONAL COMPUTER ("USAF LOOP", "RAAF
LOOP", OR "COMBINED USAF/RAAF LOOP").
3. SELECT THE DESIGNATED FUEL OPERATION BY SETTING THE “MODE SELECT” HAND SWITCH ON
THE PUMP CONTROL PANEL (PCP) TO “FLUSH”.
A. THE BACK PRESSURE CONTROL VALVE (BPCV) WILL BE DE-ENERGIZED LOCKING THE BPCV
CLOSED.
B. THE DEFUEL/FLUSH VALVE (D/FV) SOLENOID "A" WILL BE DE-ENERGIZED AND SOLENOID "B"
WILL BE ENERGIZED ALLOWING THE D/FV TO FULLY OPEN.
4. SELECT THE DESIGNATED OPERATING TANK BY SETTING THE "LEAD TANK" HAND SELECTOR
SWITCH ON THE PCP TO THE SELECTED TANK.
5. THE "HAND-OFF-AUTO" SWITCHES, LOCATED ON THE MCC FOR THE OPERATING BULK TANK
PUMPS SHOULD BE IN THE “AUTO” POSITION. THE LOCAL "HAND-AUTO" SELECTOR SWITCH MUST
BE IN “AUTO”.
A. IF A PUMP IS TAKEN OUT OF SERVICE FOR MAINTENANCE, THE HAND SWITCH FOR THAT PUMP
SHOULD REMAIN IN THE “OFF” POSITION. THIS WILL PREVENT THE PLC FROM STARTING THE
PUMP.
B. A PUMP SET TO “HAND” MODE CAN ONLY BE MANUALLY STARTED. THIS IS FOR OPERATION
TESTING, NOT FOR NORMAL FUEL TRANSFERS.
6. INITIATE A PUMP START BY DEPRESSING THE "START" PUSHBUTTON ON THE MCC TO INITIATE
SYSTEM FLUSHING. THE PLC WILL START ONE PUMP.
7. REPEAT THE PUMP “START” CALLS TO START EACH SUBSEQUENT FUEL PUMP.
NOTE: THE PLC WILL ONLY ALLOW A MAXIMUM OF THREE (3) FUEL PUMPS AT THE BULK TANKS
TO OPERATE SIMULTANEOUSLY. THE FOURTH PUMP IS PROVIDED AS A BACKUP IN THE EVENT
THAT ONE PUMP IS OFFLINE.
8. STOP EACH PUMP, ONE AT A TIME, BY DEPRESSING THE RESPECTIVE “STOP” PUSHBUTTON ON
THE MCC TO TERMINATE THE FUEL TRANSFER.
9. POSITION MANUAL VALVES IN THEIR NORMALLY OPEN OR CLOSED POSITIONS.
10.RETURN THE SETTING OF THE “MODE SELECT” HAND SWITCH ON THE PCP TO “OFF”.
HYDROSTATIC TEST EXEMPT WELD NOTES FOR PIPING
CROSSING THE WESTERN ACCESS TRACK
1. IN ADDITION TO FINAL RADIOGRAPHIC EXAMINATION, WELDS COMPLETED ON PIPING
CROSSING THE WESTERN ACCESS TRACK MUST RECEIVE AN ENHANCED IN-PROCESS
EXAMINATION IN ACCORDANCE WITH ASME B31.3, SECTION 344.7.
2. IN-PROCESS EXAMINATION MUST BE PERFORMED BY A CERTIFIED WELDING INSPECTOR AND
INCLUDES VISUAL EXAMINATION OF:
A. JOINT PREPARATION AND CLEANLINESS
B. PREHEATING
C. FIT-UP, JOINT CLEARANCE, AND INTERNAL ALIGNMENT PRIOR TO JOINING
D. VARIABLES SPECIFIED BY THE JOINING PROCEDURE, INCLUDING FILLER MATERIAL,
POSITION, AND ELECTRODE
E. EXTERNAL CONDITION OF THE ROOT PASS AFTER CLEANING AIDED BY LIQUID PENETRANT
OR MAGNETIC PARTICLE EXAMINATION
F. SLAG REMOVAL AND WELD CONDITION BETWEEN PASSES
G. APPEARANCE OF FINISHED JOINT
ABBREVIATIONS AND LEGENDS
FLOW DIAGRAM SYMBOLSABBREVIATIONS
ABOVEGROUND TO BELOWGROUND TRANSITION
BALL VALVE
BLIND FLANGE
CAM AND GROOVE TYPE COUPLING
CHECK VALVE - SWING TYPE
CONNECT TO EXISTING
CONTROL VALVE TAG
DB&B VALVE LR/DTR (ARROW INDICATES DIRECTION
OF RELIEF)
DIAPHRAGM CONTROL VALVE - GLOBE PATTERN
DOUBLE BLOCK AND BLEED (PLUG) VALVE
FLOW ARROW (INDICATES DIRECTION OF FLOW)
LIMITS OF REMOVAL (REMOVE ON SHADED SIDE)
PIPE CAP (THREADED OR SOCKET WELDED)
REDUCER (CONCENTRIC)
REDUCER (ECCENTRIC)
TANK UNIT (DRY DISCONNECT)
VALVE IDENTIFICATION TAG
AG BG
CVT
VXXXXX
AG ABOVE GRADE
API AMERICAN PETROLEUM INSTITUTE
ASME AMERICAN SOCIETY OF MECHANICAL
ENGINEERS
AVTUR AVIATION TURBINE FUEL
BCR BODY CAVITY RELIEF
BF BLIND FLANGE
BG BELOW GRADE
BOP BOTTOM OF PIPE
CENTERLINE
DB&B DOUBLE BLOCK AND BLEED
DEMO DEMOLITION
DIA OR Ø DIAMETER
DN DIAMETER NOMINAL
ECC ECCENTRIC
EI ENERGY INSTITUTE
ELEV ELEVATION
ESD EMERGENCY SHUTDOWN
ETC ET CETERA
F-34 OR F34 MILITARY GRADE JET FUEL
FOT FLAT ON TOP
FRP FIBERGLASS REINFORCED PLASTIC
FSII FUEL SYSTEM ICING INHIBITOR
GTAW GAS TUNGSTEN ARC WELDING
HPV HIGH POINT VENT
HOPV HYDRANT OUTLET PIT VALVE
HHT HYDRANT HOSE TRUCK
IF INSULATING FLANGE
L LITERS
LC LOCK CLOSED
LO LOCK OPEN
LPM LITERS PER MINUTE
LPD LOW POINT DRAIN
LR/DTR LINE RELIEVING/ DIFFERENTIAL THERMAL
RELIEF
m METER (DIMENSION) mm MILLIMETER
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MIL MILITARY
MIN MINIMUM
NC NORMALLY CLOSED
NO NORMALLY OPEN
NPT NATIONAL PIPE THREAD
NTS NOT TO SCALE
PC PRESSURE CONTROL
PI PRESSURE INDICATOR
POL PETROLEUM, OIL, AND LUBRICANTS
PRV PRESSURE RELIEF VALVE
PT POINT
RAAF ROYAL AUSTRALIAN AIR FORCE
RED REDUCER/REDUCING
SCH SCHEDULE
SDERP STANDARD DOME EARTH REFERENCE POINT
SG SPECIFIC GRAVITY
SS STAINLESS STEEL
SW SOCKET WELDED
THD THREADED
THK THICK
TYP TYPICAL
USAF UNITED STATES AIR FORCE
V VALVE
W/ WITH
# NUMBER OR POUND
± PLUS/MINUS
LC
FLOW DIAGRAM LINE DESIGNATIONS
BOUNDARY OR LIMITS
EXISTING MAJOR PIPING
EXISTING MINOR (SMALL BORE)
PIPING
MAJOR PIPING
MINOR (SMALL BORE) PIPING
HYDRAULIC SIGNAL
PIPING REMOVAL
PIPE IS CONTINUED FROM A
DIFFERENT AREA OF THE FUEL
FARM, FLOW IS TO THE CURRENT
DRAWING
PIPE CONTINUES TO A DIFFERENT
AREA OF THE FUEL FARM, FLOW
IS FROM THE CURRENT DRAWING
PIPE SIZE AND MATERIAL
IDENTIFICATION
DNXX-XX
PIPE MATERIAL
PIPE SIZE (DIAMETER NOMINAL)
MP001
D N
N C
DN250-SS HYDRANT
LOOP PIPING
HYDRANT
OUTLET PIT
(TYP OF 6)
EXISTING HYDRANT LOOP
CROSSOVER VALVE PIT
DN250-SS
ISOLATION
VALVE PIT
D N
D
N
BG AG
BG
AG
AG
BG
HPV
D N
HPV
D N
H
PV
DN50
D N
N O
EXISTING HYDRANT LOOP
CROSSOVER VALVE PIT
DN250-SS
DN250-SS
DN250
FULL
PORT
NC
D N
AG BGBG AG
HPV
D N
H
PV
DN50
V25007
V2
REMOVE DN25
BLIND FLANGE
(TYP OF 2)
V2
D N
IF
DN250
FULL PORT
NO
V25006
IF
LPD
V2
DN250
FULL
PORT
NC
V25006
D N
LPD
HPV
D N
D
N
DN250-SS
RETURN TO
FILTER BUILDING
DN250-SS ISSUE
FROM FILTER
BUILDING
DN250-SS
RETURN TO
FILTER BUILDING
DN250-SS ISSUE
FROM FILTER
BUILDING
DN250
FULL PORT
NO
V25007
IF
D N
HPV
D N
IF
FU
LL
PO
R
T N
O
HPV
D N
IF
IF
IF
FINAL SUBMITTAL
REENIGNELANOISSEFORPDERETSIGER DUNCAN KEITH
ME-1050291/24/23
DN250-SS
DN250-SS
DN100-SS DN100-SS
DN100-SS DN100-SS
D N
HPV
IF
D N
HPV
LPD LPD
IF
HPV
IF
HPV
LPD LPD
IF
HPV
IF
HPV
LPD LPD
IF
LPD
IF
LPD
IF
TEE W/ PIG BARS
(TYP OF EACH
HYDRANT OUTLET PIT)
AG BG
SACRIFICIAL
ANODE
IMPRESSED
CURRENT
IMPRESSED
CURRENT
SACRIFICIAL
ANODE
C2HYDRANT LOOP CROSSOVER VALVE PIT REMOVALS
A1HYDRANT LOOP CROSSOVER VALVE PIT MODIFICATIONS AND HYDRANT LOOP
DN40
HPV
FULL PORT
(TYP OF 6)
BC
R
HPV
IF
DN250-SS
ESD
ESD PUSHBUTTON (TYP OF 7)
SEE ELECTRICAL
ESD
EXISTING ESD PANEL
AT CONTROL ROOM
D N
D N
D N
D N
D N
D N
D N
D N
D N
D N
D N
D N
D N
D N
V2
H
O
PV
IF V2
H
O
PV
IF V2
H
O
PV
IF
V2
H
O
PV
IF
V2
H
O
PV
IF
V2
H
O
PV
IF
DN100-SS
DN100-SS DN40
HPV
MP011
DN40 NIPPLE, PLAIN
BOTH ENDS (TYP)
DN40 SW ELBOW (TYP)
DN40 BALL VALVE (NC)
DN40 FLANGE (TYP)
WELDED BRANCH FITTING
FUEL PIPE
(SIZE VARIES)
NOTES
1. ADJUST LENGTH IN VALVE PITS WHERE INDICATED TO EXTEND
VENT OUTLET AND VALVE ABOVE FLOOR GRATING.
MINIMIZE
N O
TE
DN40 TANK UNIT W/ INTEGRAL
PRESSURE EQUALISING
VALVE AND DUST CAP
DN40 NIPPLE, PLAIN
BOTH ENDS (TYP)
FUEL PIPE
(SIZE VARIES)
DN40 BALL VALVE (NC)
WELDED BRANCH FITTING
DN40 FLANGE
NOTES
1. PROVIDE ADDITIONAL ELBOW AND PIPE WHERE INDICATED TO
EXTEND DRAIN CONNECTION AND VALVE ABOVE FLOOR
GRATING.
DN40 TANK UNIT W/ INTEGRAL
PRESSURE EQUALISING
VALVE AND DUST CAP
PROTECTED PIPE
NOTES
1. PROVIDE BRANCH CONNECTION AND BALL VALVE AT 12 O'CLOCK, 3 O'CLOCK, OR 9
O'CLOCK POSITIONS AS INDICATED ON PLAN SHEETS.
2. CHECK VALVE MUST BE INSTALLED HORIZONTALLY AS INDICATED.
3. ADJUST DIMENSIONS AND ROUTE BYPASS PIPING AS REQUIRED TO CLEAR CONFLICTS.
4. RELIEF PIPING AND VALVE MATERIALS MUST BE AS INDICATED ON FLOW DIAGRAM AND
PLAN SHEETS.
5. LOCK BALL VALVES OPEN USING PLASTIC STRAPS (CAR SEALS).
DN25 SWING CHECK VALVE
DN250 FUEL PIPE
DN25 WELDED
BRANCH FITTING
DN25 PIPE
DOWNSTREAM TIE-IN
DN25 BALL VALVE
FIELD DETERMINE
(NOTE 3)
TO
DOWNSTREAM
TIE-IN
FROM
CHECK
VALVE
FIELD DETERMINE
(NOTE 3)
EXISTING
DN250 FUEL PIPE
EXISTING
DN25 BALL VALVE
BRANCH PIPE
MAIN
LINE PIPE
GUIDE BARS 50mm x 10mm
FLAT BAR COPE TO FIT
STRAIGHT TEE OR
REDUCING TEE FITTING
(TYP)
"A"
"B"
"B"
"A"
BARRED TEE PLAN BARRED TEE SECTION "A"
BARRED TEE SECTION "B"
NOTES
1. DN250 x DN200 REDUCING TEE SHOWN. OTHER BRANCH SIZES SIMILAR. SEE TABLE.
2. GUIDE BAR MATERIAL TO MATCH PIPE MATERIAL.
X X
X X
LC
LC
LC
LC
LC
GUIDE BAR DIMENSION
TABLE
BRANCH
SIZE
NO OF
BARS "X"
DN100 1 50 mm
"A" FUEL PIPE "B" CASING
SLEEVE
DN250 DN350
75 mm ANCHOR COLLAR/ WATER STOP, CONTINUOUSLY WELDED TO CASING
SLEEVE ON BOTH SIDES
STEEL CASING SLEEVE "B"
BUNA-N CASING END SEAL
STAINLESS STEEL BAND CLAMPS
FUEL PIPE "A"
MODULAR NITRILE RUBBER SEAL WITH
STAINLESS STEEL HARDWARE (TYP OF 2)
NOTES
1. FOR HYDRANT LOOP CROSSOVER VALVE PIT PIPING PENETRATIONS, THE CASING SLEEVE IS EXISTING AND MUST
REMAIN. PROVIDE CASING SPACER, MODULAR NITRILE RUBBER SEALS, AND CASING END SEAL WITH BAND CLAMPS.
2. FOR ISOLATION VALVE PIT PIPING PENETRATIONS, PROVIDE CASING SLEEVE. CASING SLEEVE MUST BE INSTALLED
DURING CONSTRUCTION OF THE CONCRETE WALL.
3. CASING SLEEVE MUST BE STANDARD WEIGHT CARBON STEEL PIPE WITH A HOT-DIP GALVANIZED PROTECTIVE
COATING.
4. CONCRETE WALL REINFORCEMENT NOT SHOWN. REFER TO STRUCTURAL SP503 FOR CONCRETE PIT DESIGN.
5. CASING SPACER MUST HOLD CENTERLINE OF FUEL PIPE ON CENTERLINE OF CASING SLEEVE.
6. INSTALL CASING SLEEVE FLUSH WITH INTERIOR WALL.
MIN
INTERIOR
CONCRETE WALL
NON-METALLIC CASING SPACER
UNDERGROUND COATING
MUST EXTEND TO
FLUSH W/ THE WALL
EXTERIOR
1. LABELS MUST BE IN ACCORDANCE WITH THE FUEL SERVICE BRANCH - DEFENCE FUEL INSTALLATION DESIGN PRACTICES MANUAL
APPENDIX D DATED APRIL 2017.
2. LABEL MUST BE COLOR CODE 642 NIGHT BLACK AND WHITE.
3. FONT MUST BE SERIES C OR D CAPITAL LETTERS FROM AS 1744.
4. LETTER HEIGHT MUST BE 24mm MINIMUM.
5. PROVIDE DIRECTION OF FLOW ARROWS AS SHOWN.
6. LABELS FOR PIPES LESS THAN DN40 MUST BE AS INDICATED AND MUST BE A CONTINUOUS BAND WRAPPED AROUND THE
CIRCUMFERENCE OF THE PIPE WITH WORDS ORIENTED LONGITUDINALLY ALONG THE PIPE.
7. PROVIDE LABELS ADJACENT TO WALL PENETRATIONS IN VALVE PITS.
8. LABELS MUST BE ABLE TO WITHSTAND EXTREME WEATHER CONDITIONS FOR AT LEAST ONE YEAR, AND MUST BE RESISTANT TO
JET FUEL, OIL, GREASE, SOLVENTS, DETERGENTS, AND WATER.
375 MIN
PIPES DN40 AND GREATER
WHITE LETTERS ON
BLACK BACKGROUND
FLOW ARROW (TYP)
F34 (AVTUR + FSII)50
PIPES LESS THAN DN40
F34 (AVTUR + FSII)
F34 (AVTUR + FSII)
F34 (AVTUR + FSII)25
FINAL SUBMITTAL
REENIGNELANOISSEFORPDERETSIGER DUNCAN KEITH
ME-1050291/24/23
1000mm
1:10
D2LOW POINT DRAIN (LPD)
SCALE: 1:10mm
B1CHECK VALVE RELIEF ASSEMBLY
SCALE: 1:10mm B2TEE W/ PIG BARS
SCALE: 1:10mm B4CONCRETE PIT WALL PENETRATION SCALE: 1:10mm
D1HIGH POINT VENT (HPV)
SCALE: 1:10mm
A2PIPE SIGNAGE
SCALE: 1:2mm
GRAPHIC SCALE
200mm
1:2
MP501
BAR GRATING
(NOTE 3)
FINISH GRADE
CONCRETE WALL
PENETRATION (TYP)
DN40
HPV
DN250
FULL PORT
DN250 HYDRANT
LOOP RETURN TO
FILTER BUILDING
DN50
HPV
V25007
V25008 IF
DN250 HYDRANT
LOOP RETURN
FROM B-52 APRON
DN250
BOP
SEE SHEET CX201
DN25 DOUBLE CHECK VALVE
RELIEF ASSEMBLY (BEHIND)
NOTE 8
PIT SUMP
APPROXIMATE ROLLING
PIT COVER BOUNDARY
DN250 HYDRANT
LOOP RETURN TO
FILTER BUILDING
LADDER
EXISTING VALVE PIT
DN250 HYDRANT
LOOP ISSUE FROM
FILTER BUILDING
D N
DN250 DN250
DEMOLISH
PIGGING LOOP
NOTE 2
DN250
NOTE 2
DN25 HPV
3 200 ± 800
IF
IF
DN50 LPD
PIT SUMP
APPROXIMATE ROLLING
PIT COVER BOUNDARY
DN250 HYDRANT
LOOP RETURN TO
FILTER BUILDING
LADDER
EXISTING VALVE PIT
D N
DN250
CONCRETE WALL
PENETRATION,
NOTE 1 (TYP OF 2)
DN250 HYDRANT
LOOP ISSUE FROM
FILTER BUILDING
NOTE 2
DN250
NOTE 2
DN25 DOUBLE
CHECK VALVE
RELIEF ASSEMBLY
(TYP OF 2)
DN250 HYDRANT
LOOP RETURN
FROM B-52 APRON
DN250 HYDRANT
LOOP ISSUE TO
B-52 APRON
MP502
A1 700 ± 100
DN40 HPV
IF
IF IF
IF
CIVIL/MECHANICAL
COORDINATION
POINT, SEE CX101
CIVIL/MECHANICAL
COORDINATION
POINT, SEE CX101
DN40 HPV
NOTE 9
NOTE 9
LIMITS OF
PNEUMATIC
PIGGING
SEE NOTE 78 000
(MAX)
SHEET NOTES
1. FOR CONCRETE WALL PENETRATION DETAIL, SEE B4/MP501.
2. REMOVE DN25 BLIND FLANGE AND CONNECT CHECK VALVE
RELIEF ASSEMBLY.
3. CUT GRATING TO PASS LOW POINT DRAINS AND HIGH POINT
VENTS TO THE ELEVATION INDICATED. THERE MUST BE
25-50mm GAP BETWEEN GRATING AND FUEL PIPING OR VALVES.
GRATING MUST NOT BE IN CONTACT WITH PIPING OR VALVES.
4. FOR HIGH POINT VENT (HPV) DETAIL, SEE D1/MP501.
5. FOR INSULATING FLANGE (IF) DETAIL, SEE C3/EK502.
6. FOR CHECK VALVE RELIEF ASSEMBLY DETAIL, SEE B1/MP501.
7. PNEUMATIC PIGGING OF THE HYDRANT PIPING PROVIDED
UNDER THIS CONTRACT MUST OCCUR PRIOR TO CONNECTING
TO THE EXISTING VALVES IN THE PIT AND PRIOR TO PROVIDING
THE LAST SEVERAL METERS OF PIPING OUTSIDE THE EAST
SIDE OF THE PIT. LAUNCH AND RECEIVE PNEUMATICALLY RUN
PIGS FROM A LOCATION 3 TO 8 METERS OUTSIDE THE EAST
SIDE OF THE PIT.
8. MODIFY GRATING TO ALLOW HPV (TYP OF 2) TO PASS
THROUGH. PROVIDE 25 mm CLEARANCE BETWEEN PIPE AND
GRATING. GRATING MUST NOT BE IN CONTACT WITH PIPING.
BAND EDGES OF GRATING OPENINGS WITH BARS OF THE SAME
OR GREATER THICKNESS THAN THE METAL USED FOR
GRATING.
FINAL SUBMITTAL
REENIGNELANOISSEFORPDERETSIGER DUNCAN KEITH
ME-1050291/24/23
A1HYDRANT LOOP CROSSOVER VALVE PIT SECTION
SCALE: 1:20mm
2000mm
1:20
10000
C1HYDRANT LOOP CROSSOVER VALVE PIT PIPING DEMOLITION PLAN
SCALE: 1:20mm C4HYDRANT LOOP CROSSOVER VALVE PIT PIPING PLAN
SCALE: 1:20mm
MP502
MP503
A183
COVER ASSEMBLY WITH 457mm
DIAMETER LID, RATED FOR
AIRCRAFT WHEEL LOADS
COLOR CODED SERVICE
INSERT FOR JP-8 JET FUEL
HOLD DOWN BOLTS BY
MANUFACTURER (TYP OF 3)
SERVICE LETTERING
IF
PROVIDE
CONE STRAINER
DN100 FULL PORT BALL VALVE WITH GEAR OPERATOR
CONCRETE ANCHOR (TYP OF 2)
DN100 HYDRANT OUTLET PIT VALVE WITH API ADAPTOR
DN100 WELDNECK FLANGE
REMOVABLE HANDLE WHEEL ACTUATOR
EXTERNAL EARTHING CONNECTION
INTEGRAL GALVANIZED STEEL FLANGE
ENVIRONMENTAL SEAL BETWEEN STEEL
PIT BODY AND FIBERGLASS PIT BODY
CROWN
GRADE
TWO-PIECE FIBERGLASS PIT BODY, 6mm THICK
BACKFILL RETENTION RING
PIT LID (CLOSED POSITION)
PIT LID (OPEN POSITION)
BOP SEE
CIVIL FUELS DN250 HYDRANT LOOP
FI
EL
D D
ET
ER
M
IN
E
DN250 x DN100
REDUCING TEE
W/ PIG BARS
B2
MP501
HYDRANT OUTLET PIT VALVE EARTHING, C1/MP504
NOTES
1. FILL/CONCRETE TO BE EXCLUDED FROM ANNULUS BETWEEN INNER AND OUTER PIT BODY.
2. SEE CIVIL (CX) FOR PIT LOCATIONS, PIT LID ELEVATIONS, AND PIPING PLANS AND PROFILES.
D N
75 mm ANCHOR COLLAR/ WATER STOP
WELDED TO FUEL PIPE AND MOLDED INTO
FIBERGLASS BY PIT MANUFACTURER
INTERNAL EARTHING CONNECTION
FINAL SUBMITTAL
REENIGNELANOISSEFORPDERETSIGER DUNCAN KEITH
ME-1050291/24/23
1000mm
1:10
SHEET NOTES
1. REFER TO DETAIL B2/CR516 FOR FUEL HYDRANT PIT
REINFORCED CONCRETE SURROUND.
2. FOR INSULATING FLANGE (IF) DETAIL, SEE C3/EK502.
A1HYDRANT OUTLET PIT SECTION
SCALE: 1:10mm
C1HYDRANT OUTLET PIT PLAN
SCALE: 1:10mm
MP503
THERMITE WELD (NOTE 1)
13 mm MONEL OR
BRONZE NUTS & WASHERS
55 mm² TW COPPER CABLE TO
STANDARD DOME EARTH
REFERENCE POINT (SDERP)
FLANGE BOLT
13 mm COPPER
EARTH ROD,
THREADED ONE END
COPPER EARTHING
LUG, THERMITE WELD
OR HYDRAULIC CRIMP
CABLE TO LUG
NORMAL
BOLTED
FLANGE
FIBERGLASS PIT WALL
70 mm² BARE
COPPER CABLE
NOTES
1. MAKE THERMITE WELD BEFORE INSERTING ROD THROUGH FIBERGLASS PIT WALL
TO PREVENT HEAT DAMAGE TO FIBERGLASS.
2. FOR STANDARD DOME EARTH REFERENCE POINT (SDERP) SEE DETAIL A3/E-516.
55 mm² TW COPPER CABLE TO
STANDARD DOME EARTH
REFERENCE POINT (SDERP)
FLANGE BOLT
COPPER EARTHING
LUG, THERMITE WELD
OR HYDRAULIC CRIMP
CABLE TO LUG
NORMAL
BOLTED
FLANGE
CONCRETE PIT WALL
NOTE
1. FOR STANDARD DOME EARTH REFERENCE POINT (SDERP), SEE DETAIL A3/E-516.
CAST CABLE
INTO CONCRETE
55 mm² TW COPPER CABLE TO
STANDARD DOME EARTH
REFERENCE POINT (SDERP)
70 mm² BARE
COPPER CABLE
FLANGE BOLT
COPPER EARTHING
LUG, THERMITE WELD
OR HYDRAULIC CRIMP
CABLE TO LUG
CONNECT TO EXTERNAL
EARTHING LUG (NOTE 1)
HYDRANT OUTLET PIT VALVE
INTERNAL EARTHING CONNECTION
POINT BY PIT MANUFACTURER,
CONNECT EARTHING CABLE TO CONNECTION
POINT PER MANUFACTURER'S INSTRUCTIONS
EXTERNAL EARTHING CONNECTION
POINT BY PIT MANUFACTURER
FINAL SUBMITTAL
REENIGNELANOISSEFORPDERETSIGER DUNCAN KEITH
ME-1050291/24/23
A1PIT CABLE PENETRATION AND PIT FLANGE EARTHING 1
SCALE: NTS A3PIT CABLE PENETRATION AND PIT FLANGE EARTHING 2
SCALE: NTS
NOTES
1. MAKE CONNECTION USING MONEL BOLTS, NUTS, AND WASHERS (SHOWN), OR USING A THERMITE WELD.
MAKE CONNECTION BEFORE CASTING IN CONCRETE.
2. FOR STANDARD DOME EARTH REFERENCE POINT (SDERP) DETAIL, SEE A3/E-516.
C1HYDRANT OUTLET PIT VALVE EARTHING
SCALE: NTS
MP504
CONCRETE
VALVE VAULT
WITH ROLLING
PIT COVER
LADDER
1 250
CONCRETE WALL
PENETRATION
(TYP OF 2)
MP505
A1 DN250
FULL PORT
DB&B PLUG
VALVE
D
IR
EC
TI
O N
O F
R O
LL
IN
G P
IT
C
O
VE
R O
PE
N
IN
G
SHEET
NOTE 2
DN40 HPV
(TYP OF 2)
(TYP)
3D ELBOW (TYP)
SEE CIVIL FUELS FOR HYDRANT
LOOP PLANS AND PROFILES
CIVIL/MECHANICAL
COORDINATION POINT,
SEE CX502
1 750±1001 750±100
HPV/LPD PIPE
SUPPORT
(TYP OF 2)
IF IF
SP503
C1
CIVIL/MECHANICAL
COORDINATION POINT,
SEE CX502
MP505
A3
FUEL LINE
M10 ADHESIVE ANCHOR W/
90mm MIN EMBED AND
EQUALLY SPACED DOUBLE
NUT (TYP OF 2)
40mm WIDE X 6mm THICK
PIPE HOLD DOWN CLAMP
(BY STRUT MANUFACTURER)
40mmX40mm
14 GAUGE STRUT
TYPE CHANNEL,
250mm LONG
NOTES
1. GRIND TOP EDGES OF CHANNEL SMOOTH TO REMOVE BURRS, ETC.
2. CHANNEL AND PIPE CLAMP MUST BE HOT-DIP GALVANIZED AFTER CUTTING
TO LENGTH AND DRILLING HOLES.
3. PROVIDE 3mm THICK PTFE PAD BETWEEN THE PIPE AND CHANNEL AND
BETWEEN PIPE AND HOLD DOWN CLAMP.
PIT WALL
BOP
SEE SHEET CX208
(M
IN
FINISH GRADE
PROVIDE VALVE
HANDWHEEL ABOVE
GRATING
BAR
GRATING
CONCRETE WALL
PENETRATION
(TYP OF 2)
LADDER
BOP
SEE SHEET CX208
SHEET
NOTE 1
HPV/LPD
SUPPORT
(TYP OF 2) MP505
A3
DN250
HYDRANTIF IF
DN40 HPV
(TYP OF 2)
(M
AX
FI
EL
D
V
ER
IF
Y
PIT CABLE PENETRATION AND
PIT FLANGE EARTHING 2 (TYP OF 2),
SEE SHEET NOTE 8
FINAL SUBMITTAL
REENIGNELANOISSEFORPDERETSIGER DUNCAN KEITH
ME-1050291/24/23
500mm
1:5
FINAL SUBMITTAL
REENIGNELANOISSEFORPDERETSIGER DUNCAN KEITH
ME-1050291/24/23
2000mm
1:20
10000
C1ISOLATION VALVE PIT PIPING PLAN
SCALE: 1:20mm
A1ISOLATION VALVE PIT SECTION
SCALE: 1:20mm A3HPV/LPD PIPE SUPPORT
SCALE: 1:5mm
SHEET NOTES
1. PROVIDE HAND WHEEL EXTENSIONS ON DB&B PLUG VALVES.
COORDINATE EXTENSION LENGTH TO PREVENT INTERFERENCE
WITH GRATING AND ROLLING PIT COVER.
2. FOR PIPE SIGNAGE DETAIL, SEE A2/MP501. FLOW DIRECTION
ARROW AS INDICATED ON MP011.
3. FOR HIGH POINT VENT (HPV) DETAIL, SEE D1/MP501.
4. FOR CONCRETE WALL PENETRATION DETAIL, SEE B4/MP501.
5. REFER TO DETAIL C1/SP503 FOR CONCRETE PIT DESIGN.
6. REFER TO DETAIL C1/SP505 FOR ROLLING PIT COVER DESIGN.
7. FOR INSULATING FLANGE (IF) DETAIL, SEE C3/EK502.
8. CONNECT EARTHING CABLE TO VALVE INLET FLANGE. ROUTE
EARTHING CABLES TO ONE EARTH STAKE. PROVIDE ONE 3 m EARTH STAKE BETWEEN 300 mm AND 450 mm FROM PIT OUTER
EDGE.
This is the start of the file's text. The full file is on GovTribe.