Supplemental Hazardous Materials Building Survey Report
Store House Building No. 65 Sandy Hook Unit of the Gateway National Recreation Area Sandy Hook, New Jersey
June 30, 2017
Mabbett & Associates, Inc. www.mabbett.com
5 Alfred Circle Bedford, MA 01730‐2318 T. 781‐275‐6050 Massachusetts | Virginia | Rhode Island | New Jersey
© 2017, Mabbett & Associates, Inc.
Prepared for:
DHM Design Corporation 900 S. Broadway, Suite 300 Denver, CO 80204
SUPPLEMENTAL HAZARDOUS MATERIALS BUILDING SURVEY REPORT
Building No. 65 | Sandy Hook, NJ
© 2017, Mabbett & Associates, Inc. Page i June 30, 2017 Project No. R2016002.001.006.002 S:\ADMINA\2016002 DHM Design\001\006\002\HAZMAT-BldgMatRpt-Bldg 65.docx
ACKNOWLEDGEMENT
This Supplemental Hazardous Materials Building Survey Report has been prepared for the sole and exclusive use of DHM Design (Client). This report is subject to and issued in connection with a Task Order Agreement between Mabbett & Associates, Inc. (Mabbett®) and DHM Design, originally dated 3 February 2016 and modified 6 June 2017. Any use or reliance upon information provided in this plan, without the specific written authorization of the Client and Mabbett, shall be at the User’s sole risk.
The report presented herein is based solely upon the laws and regulations existing as of the date of this report as well as information gathered to date. Should further environmental or other relevant information be developed at a later date, the Client should bring such information to the attention of Mabbett as soon as possible. If any of the information provided to Mabbett for the preparation of this report is incorrect, incomplete, or subject to change based upon an evaluation, Mabbett would wish to modify this report and its conclusions.
The attached Supplemental Hazardous Building Materials Survey Report was prepared by the following Mabbett & Associates, Inc. personnel:
Michael F. Delaney Sr. Project Manager │Asbestos Inspector/Designer
This report has been reviewed and approved by:
Freddie J. Ferreira, CPG, MBA Director of Environment & Infrastructure
Building No. 65 | Sandy Hook, NJ
© 2017, Mabbett & Associates, Inc. Page ii June 30, 2017 Project No. R2016002.001.006.002 S:\ADMINA\2016002 DHM Design\001\006\002\HAZMAT-BldgMatRpt-Bldg 65.docx
TABLE OF CONTENTS
SECTION PAGE
1.0 INTRODUCTION
1.1 Project Location and Building Description
1.2 Project Objectives
2.0 ASBESTOS SURVEY
2.1 Sampling Methodology
2.2 Analytical Methodology
2.3 Summary of Asbestos Containing Materials Findings
3.0 LEAD SCREENING SURVEY
3.1 Screening Survey and Sampling Methodology
3.2 Summary of Lead Paint Chip Screening Survey Findings
4.0 ASSESSMENT OF MATERIALS FOR PCB
5.0 INENTORY OF OTHER MISCELLANEOUS MATERIALS
6.0 CONCLUSIONS AND RECOMMENDATIONS
6.1 Asbestos Conclusions and Recommendations
6.2 Lead Containing Paint
6.3 Other Miscellaneous Materials
7.0 LIMITATIONS
Tables
Table 1 Summary of Asbestos Containing Materials Table 2 Summary of Lead in Paint Chip Sampling Results Table 3 Inventory of Other Miscellaneous Materials
Figures
L-1 Site Locus Map L-2 Site Plan ASB/Pb-1 1st Floor Asbestos and Lead Paint Survey Plan ASB/Pb-2 Attic Asbestos and Lead Paint Survey Plan
Appendices
Appendix A Summary of ACM Building Survey Results, Including Negative Results Appendix B Laboratory Reports and Chains-of-Custody Appendix C Project Photo-Log
Store House Building No. 65 | Sandy Hook, NJ
© 2017, Mabbett & Associates, Inc. Page 1 June 30, 2017 Project No. R2016002.001.006.002 S:\ADMINA\2016002 DHM Design\001\006\002\HAZMAT-BldgMatRpt-Bldg 65.docx
1.0 INTRODUCTION
This report presents the results of a Supplemental Hazardous Materials Building Survey completed by Mabbett and Associates, Inc. (Mabbett®) on the interior and exterior of Building No. 65 located within the boundaries of the Sandy Hook Unit of the Gateway National Recreation Area (Gateway NRA) on Kearney Road in Sandy Hook, New Jersey. The Hazardous Materials Building Survey was conducted by Mabbett as a subcontractor to DHM Design (DHM) under Contract No. P15PC00039, Task Order No. P16PD00163, dated 3 February 2016 and modified 6 June 2017, in support of DHM’s A/E Northeast Region Indefinite Quantities Contract for design services for design development and construction documents (DD/CD) with the National Park Service (NPS). This survey is supplemental to limited Asbestos Containing Building Material Survey completed by Environmental Connection, Inc. (EC), report dated 28 July 2008. The objective of the survey was to quantify the volume of hazardous materials within the interior and exterior of Building No. 65 so that an abatement scope and associated cost can be incorporated into DHM’s design documents being developed for building rehabilitation. Building No. 65 was vacant at the time of the survey.
The Hazardous Materials Building Survey was comprised of three primary project tasks including:
▪ Evaluation of previous survey data and existing site conditions and formulate a sampling plan.
▪ Site survey to collect building material samples for laboratory analysis.
▪ Development of this Supplemental Hazardous Materials Building Survey Report.
The site survey for building material sampling purposes was performed by Mabbett personnel on 8 June 2017.
Mabbett inspectors were trained pursuant to Title II of the Toxic Substance Control Act, 15 U.S.C 2646. This project deliverable is supported by a series of tables, figures and appendices that are imbedded within this report or provided as attachments.
1.1 Project Location and Building Description
Building No. 65 is the former Store House and is located within the boundaries of Sandy Hook Unit of Gateway NRA in Sandy Hook, a barrier spit in Middletown Township, Monmouth County, New Jersey. The Sandy Hook barrier spit is approximately 6 miles in length and varies in width from 0.1 to 1.0 mile along the northern end of the Jersey Shore. Sandy Hook is surrounded by Sandy Hook Bay to west and encloses the southern entrance of Lower New York Bay south of New York City, protecting it from the open waters of the Atlantic Ocean to the east. A site locus map illustrating the Sandy Hook barrier spit is provided as Figure L-1. Building 65 is situated in the northeastern portion of the Sandy Hook barrier spit along Kearney Road. The structure is surrounded to the north, east, and south by sparse woodlands and to the west by a series of structures that abut Kearney Road. A Site Plan depicting Building 65 and the immediate surrounding areas is presented as Figure L-2.
Building No. 65 was reportedly built in the early 1900s during construction of the actual Fort. The building, approximately 2,300 square feet in size, consists of a two-story brick structure with a wood framed roof on a block foundation with crawl space basement, and is finished with brick siding and a pitched slate roof. The majority of the interior finishes consist of painted block and brick walls, ceilings, timber columns and wood floors. A walkthrough of the building conducted by Mabbett did identify some gypsum wallboard walls, ceiling tiles, and floor tile finishes. The building was vacant at the time of the survey and inhabited by racoons, which have caused considerable damage to ceilings throughout the 1st floor.
1.2 Project Objectives
This project was designed to accomplish two primary objectives: to collect a representative number of building materials for laboratory analysis and reporting; and to use data from the laboratory analysis efforts to estimate the volume of hazardous materials present within the building’s interior and exterior for DHM’s subsequent use in development of an abatement scope and cost. These two objectives were
© 2017, Mabbett & Associates, Inc. Page 2 June 30, 2017 Project No. R2016002.001.006.002 S:\ADMINA\2016002 DHM Design\001\006\002\HAZMAT-BldgMatRpt-Bldg 65.docx met through a combination of a site visit and inspection to collect building material samples for laboratory analysis, and interpretation of qualitative data collected in the field, and the quantitative laboratory data generated from analysis of the building materials as summarized in this survey report.
2.0 ASBESTOS SURVEY
The asbestos survey component of this project was completed on 8 June 2017 by Mr. Michael Delaney, a Mabbett credentialed and United States Environmental Protection Agency (EPA) accredited asbestos inspector and designer.
The asbestos survey sampling strategy, sampling methodologies, and sample quantities were determined by a review of the limited Asbestos Containing Building Material Survey conduct by EC in 2008.
2.1 Sampling Methodology
The site survey and sampling activities were completed in accordance with the proposed scope of work.
Mabbett were able to access all areas of the interior and exterior of the building where suspect asbestos containing material (ACM) was present. Suspect ACM’s were collected using EPA National Emissions Standards for Hazardous Air Pollutants (NESHAP), 40 CFR Part 763 and Asbestos Hazard Emergency Response Act (AHERA) protocols. Bulk samples of suspect ACM were collected in accordance with AHERA and was conducted according to the following sampling plan:
Surfacing material:
✓ At least three bulk samples shall be collected from each homogeneous area that is 1,000 ft2 or less.
✓ At least five bulk samples shall be collected from each homogeneous area that is greater than 1,000 ft2 but less than or equal to 5,000 ft2.
✓ At least seven bulk samples shall be collected from each homogeneous area that is greater than 5,000 ft2.
Thermal system insulation:
✓ At least three bulk samples shall be collected from each homogeneous area of thermal system insulation.
✓ At least one bulk sample shall be collected from each homogeneous area of patched area of thermal system insulation.
✓ Sufficient samples shall be collected from elbows and fittings to determine if they contain
ACM.
✓ Bulk samples shall not be collected from any homogeneous area where the state licensed asbestos inspector determined that the thermal system insulation is fiberglass, foam glass, rubber, or other non-ACM.
Miscellaneous material:
✓ At least one bulk sample shall be collected from each homogeneous area that is less than 100 ft2.
✓ At least three bulk samples shall be collected from each homogeneous area that is greater than 100 ft2.
2.2 Analytical Methodology
The collected bulk samples were submitted under chain-of-custody (COC) procedures to EMSL Analytical, © 2017, Mabbett & Associates, Inc. Page 3 June 30, 2017 Project No. R2016002.001.006.002 S:\ADMINA\2016002 DHM Design\001\006\002\HAZMAT-BldgMatRpt-Bldg 65.docx
Inc. (EMSL) located at 1056 Stelton Road, Piscataway, New Jersey for polarized light microscopy (PLM) and transmission light microscopy (TEM) analysis of bulk materials using EPA Methods 600/R-93/116 (PLM for friable materials), 600/R-93/116 Section 2.3 (PLM for non-friable organically bound materials), and 600/R-93/116 Section 2.5.5.1 (TEM for non-friable organically bound materials). EMSL is accredited by the American Industrial Hygiene Association (AIHA) and participates in the National Voluntary Laboratory Accreditation Program (NELAP NJ Certification No. 03036).
The bulk sample results from this ACM survey are presented in Appendix A - Summary of ACM Building Survey Results. The New Jersey Department of Environmental Protection (NJDEP) defines any material that contains greater than one percent (>1%) asbestos as being an ACM. As such, the analytical laboratory identified bulk samples as positive for asbestos that met the regulatory criteria of greater than one percent (>1%) asbestos. Laboratory reports and COC documentation are provided in Appendix B of this report.
2.3 Summary of Asbestos Containing Materials Findings
Mabbett identified seventeen (17) types of homogenous materials and collected fifty-one (51) representative bulk ACM samples. An asbestos survey plan of the building 1st floor and attic are provided as Figures ASB-1 and ASB-2, respectively. The laboratory reported analytical data, including available historical data utilized for this survey, indicated that eight (8) homogenous materials had greater than 1% asbestos and were positive ACM. Estimated quantities of materials identified as ACM are presented in Table 1 below:
Table 1 – Summary of ACM
Location Description of Material Estimated Quantity
Amount Units
1st Floor 9" x 9" Floor Tile and Associated Mastic 600 SF
Attic Insulating Sleeve Stock Pile 1 CY
Boiler Room Boiler Rib Packing 3' x 5' Boiler
Boiler Room Boiler Insulation 100 SF
Boiler Room Pipe and Fitting Insulation 50 LF
Boiler Room Breeching Flue Cement 2 SF
Boiler Room ACM Debris 100 SF
Roof Black Roof Flashing and Roofing
Underlayment (assumed) Not quantified, assumed throughout slate roofing system
A review of the positive ACM results listed above was then conducted to ascertain as to whether the ACM was friable or non-friable ACM. Friable ACM is defined by NESHAP as any material containing more than 1% asbestos that, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure. Friable ACM was identified in the Boiler Room. This material is also significantly damaged a may be a health hazard to anyone that might enter the room. The door was sealed shut following the survey.
© 2017, Mabbett & Associates, Inc. Page 4 June 30, 2017 Project No. R2016002.001.006.002 S:\ADMINA\2016002 DHM Design\001\006\002\HAZMAT-BldgMatRpt-Bldg 65.docx
3.0 LEAD SCREENING SURVEY
The lead screening survey component of this project was also completed on 8 June 2017. The lead screening survey and sampling strategy, screening and sampling methodologies, and sample quantities were defined in the technical approach prepared by Mabbett as part of the project scope. The previous survey conducted by EC did not include screening of materials for lead.
3.1 Screening Survey and Sampling Methodology
Mabbett conducted a LCP sampling program to measure lead concentrations in selected building surfaces through the collection of ten (10) paint chip samples for submittal to EMSL for analysis of lead content.
Samples locations are shown on Figures ASB/Pb-1 and ASB/Pb-2. The collected samples were analyzed in accordance with EPA Method SW846-3050B/7000B. A copy of the laboratory analytical report is provided in Appendix B.
3.2 Summary of Lead Paint Chip Screening Survey Findings
Paint chip results are summarized in Table 2 below:
Table 2 - Summary of Lead in Paint Chip Sampling Results
Sample # Location Substrate and Component
Color Lead Content
(Weight %)
Pb-01 1st Floor Metal Panel Gray 0.28
Pb-02 1st Floor Metal Panel White 0.24
Pb-03 1st Floor Brick Wall White 11
Pb-04 1st Floor Wood Window Casing White 6.3
Pb-05 1st Floor Wood Wall White 1.1
Pb-06 1st Floor Metal Pipe White 0.34
Pb-07 1st Floor Metal Radiator White 0.29
Pb-08 1st Floor Wood Flooring Gray 0.33
Pb-09 Attic Wood Window White 0.5
Pb-10 Attic Wood Wall Gray 0.12
The Occupational Safety & Health Administration (OSHA) does not recognize a “safe” level of lead in paint.
Depending on the method of removal used, even trace amounts of lead in paint may result in airborne concentrations of lead during removal. An employer or contractor who disturbs or removes lead paint must comply with OSHA Standard 29 CFR 1926.62, “Lead Exposure in Construction; Interim Final Rule.” In addition, results of all other paint chips collected during the screening survey of interior and exterior building components are provided in Appendix B - Summary of Lead Analysis in Paint Chips which includes a description of each sampled surface and resulting lead analysis-measured lead content by weight percent.
4.0 ASSESSMENT OF MATERIALS FOR PCB
A visual assessment and historical review of building materials and was conducted by Mabbett staff to determine if PCBs may be present. Based on the age of the building and the application of materials, it was determined that materials pre-date the application of PCB use in suspect building materials.
© 2017, Mabbett & Associates, Inc. Page 5 June 30, 2017 Project No. R2016002.001.006.002 S:\ADMINA\2016002 DHM Design\001\006\002\HAZMAT-BldgMatRpt-Bldg 65.docx
5.0 INENTORY OF OTHER MISCELLANEOUS MATERIALS
A visual screening and inventory was conducted by Mabbett staff to identify quantities of other potential hazardous, non-hazardous, or regulated building materials (RBMs) in order to define an inventory of these materials for future relocation or disposal purposes. A summary of this visual inventory is presented below in Table 3.
Table 3 - Inventory of Other Miscellaneous Materials
Item Quantity
4' Fluorescent Lamps 2
8' Fluorescent Lamps 34
Light Ballasts 20
Fire Extinguishers 3
6.0 CONCLUSIONS AND RECOMMENDATIONS
This section presents the conclusions generated from the hazardous materials building survey and sampling conducted by Mabbett at Store House Building No. 65.
6.1 Asbestos Conclusions and Recommendations
Results of our sampling efforts for ACM included the collection 51 bulk samples for laboratory analysis and reporting. Results of this effort are summarized above in section 2.3 which indicated eight (8) types of material that were ACM as follows:
1st Floor - Approximately 600 square feet of 9” x 9” floor tile and associated mastic.
Attic - Approximately 1 cubic yard of insulating sleeve material stockpiled in boxes.
Boiler Room – Boiler with ACM rib packing, 100 square feet boiler insulation, 50 linear feet pipe and fitting insulation, 2 square feet breeching flue cement and approximately 100 square feet ACM debris
Roof – Black roof flashing material associated with the slate roof.
For the purposes of developing an abatement scope and cost, all ACM materials must be removed by an Asbestos Abatement Contractor licensed by the New Jersey Department of Labor and Workforce Development (NJDOLWD). Abatement work shall also be designed/planned by a certified Asbestos Designer prior to any demolition or rehabilitation activities on the building.
All other material samples were either non-detect for ACM or were noted at “trace” levels indicating that they contain less than 1% of asbestos and, as such, are not defined as ACM by the NJDEP. For materials containing less than 1% asbestos content, the waste is not regulated under USEPA's National Emissions Standards for Hazardous Air Pollutants (NESHAP) for asbestos. This waste material in New Jersey must be managed and disposed of as ID 13C, Construction and Demolition Waste as defined at N.J.A.C. 7:26-2.13(g)iv.
It is important to note that although this was a comprehensive survey, the potential exists that other suspect materials may be encountered during demolition or rehabilitation activities that were not identified in this report. These potential scenarios would include suspect ACM that may exist within the building walls, above inaccessible hard ceilings, or in other inaccessible locations. Since this
© 2017, Mabbett & Associates, Inc. Page 6 June 30, 2017 Project No. R2016002.001.006.002 S:\ADMINA\2016002 DHM Design\001\006\002\HAZMAT-BldgMatRpt-Bldg 65.docx structure is primarily an open interior with limited finished walls or ceilings the potential for encountering suspect ACM beyond what is reported herein is limited, but should suspect ACM be identified then the material should be assumed to contain asbestos if discovered during any demolition or rehabilitation activities or until otherwise verified by a project monitor though sampling and analysis.
6.2 Lead Containing Paint
The purpose of the LCP screening survey was to identify patterns of LCP. For the purpose of this LCP screening survey, representative interior and exterior building components were tested. The regulations addressing LCP in non-residential buildings are focused on protecting workers involved with paint-disturbing activities and related waste-disposal activities.
A concentration of lead greater than or equal to 0.5 percent by weight exceeds the United States Department of Housing and Urban Development (U.S. HUD) residential standards and is an indicator of risk. OSHA does not specify a safe concentration of LCP. However, for the purposes of this LCP screening survey, lead concentrations greater than 0.5 percent by weight have been utilized as a threshold for areas where possible worker exposures may occur.
OSHA lead regulations will apply to any demolition operation (i.e. sanding, scraping, cutting, and welding) that would disturb painted surfaces which contain lead. Occupational exposure to lead is regulated by OSHA (29CFR 1910.1025) as well as applicable state regulations. These regulations involve air monitoring of workers to determine exposure levels when disturbing paint containing measurable lead. A LCP determination cannot determine a safe level of lead, but is intended to provide guidance to the locations where LCP is present. Employers and contractors may use this information to better determine worker exposure to airborne lead by understanding the different concentrations of lead paint on representative components and surfaces. Worker exposure controls can then be implemented and air monitoring can be performed during activities that disturb lead containing paint.
Disposal of materials coated with paint containing lead is subject to the USEPA RCRA regulations. At the present time, federal and state regulations do not necessarily require that materials coated with lead-based paint be removed prior to demolition. However, wastes generated are required to be characterized prior to disposal. Mabbett recommends that TCLP testing be performed on the waste stream generated from demolition activities performed at the properties inspected.
6.3 Other Miscellaneous Materials
The purpose of the inventory for other miscellaneous materials as completed by Mabbett was to identify other potential hazardous and non-building material substances for consideration prior to any planned building demolition or rehabilitation measures. An inventory of these items/materials is provided in Table No. 6 provided above in section 5.0.
It is our recommendation that these materials be removed for storage elsewhere during building demolition or rehabilitation efforts. Items listed in Table No. 3 such as ballasts and fluorescent light tubes should be managed, handled, and recycled in accordance with the prevailing NJDEP rules governing fluorescent bulbs. Ballasts should be managed in accordance with the NJDEP universal waste rules as defined within the Division of Solid and Hazardous Wastes.
© 2017, Mabbett & Associates, Inc. Page 7 June 30, 2017 Project No. R2016002.001.006.002 S:\ADMINA\2016002 DHM Design\001\006\002\HAZMAT-BldgMatRpt-Bldg 65.docx
7.0 LIMITATIONS
This screening level survey report is the result of a diligent search of the facility for ACM and other Regulated Building Materials. Although a comprehensive inspection was performed with the majority of the facility accessed for evaluation and sampling purposes, Mabbett does not claim to have identified all of the materials that may be present at/in the facility. Mabbett has conducted this assessment with reasonable care and has performed this project within generally accepted industry standards. Mabbett makes no assurances, that the information, research, and technology used to prepare this report may not change in the future, thus affecting the results reported herein.
HAZARDOUS MATERIALS BUILDING SURVEY REPORT
© 2017, Mabbett & Associates, Inc. June 30, 2017 Project No. R2016002.001.006.002 S:\ADMINA\2016002 DHM Design\001\006\002\HAZMAT-BldgMatRpt-Bldg 65.docx
FIGURES
Scientists I Engineers I Program Managers
Mabbett & Associates, Inc.
5 Alfred Circle Bedford, MA 01730-2318
T. 781-275-6050 - 800-877-6050 www.mabbett.com
SITE LOCUS
MAP
SANDY HOOK UNIT OF THE GATEWAY
NATIONAL RECREATION AREA SANDY HOOK, NEW JERSEY
HAZARDOUS MATERIALS SURVEY-BLDG. 65
SITE
SITE
LOCATION
GRAPHIC SCALE
1 INCH= FEET2000
1000' 2000' 4000'
NOTES:
1. THIS PLAN WAS DEVELOPED FROM A
GOOGLE EARTH IMAGE AND BY FIELD
OBSERVATIONS BY MABBETT PERSONNEL.
2. THIS PLAN IS FOR ILLUSTRATIVE PURPOSES ONLY,
ALL LOCATIONS ARE APPROXIMATE.
AutoCAD SHX Text
DWG. NO.
AutoCAD SHX Text
PROJ. NO.
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text 2016002.001.006
AutoCAD SHX Text L-1
AutoCAD SHX Text 1"=2000'
AutoCAD SHX Text
FJF
AutoCAD SHX Text
DJA
AutoCAD SHX Text
AutoCAD SHX Text Copyright, 2016
AutoCAD SHX Text Mabbett & Associates, Inc.
AutoCAD SHX Text C
BUILDING-65
Scientists I Engineers I Program Managers
Mabbett & Associates, Inc.
5 Alfred Circle Bedford, MA 01730-2318
T. 781-275-6050 - 800-877-6050 www.mabbett.com
SITE PLAN
SANDY HOOK UNIT OF THE GATEWAY
NATIONAL RECREATION AREA SANDY HOOK, NEW JERSEY
HAZARDOUS MATERIALS SURVEY-BLDG. 65
GRAPHIC SCALE
1 INCH= FEET40
20' 40' 80'
NOTES:
1. THIS PLAN WAS DEVELOPED FROM A
GOOGLE EARTH IMAGE AND BY FIELD
OBSERVATIONS BY MABBETT PERSONNEL.
2. THIS PLAN IS FOR ILLUSTRATIVE PURPOSES ONLY,
ALL LOCATIONS ARE APPROXIMATE.
AutoCAD SHX Text
DWG. NO.
AutoCAD SHX Text
PROJ. NO.
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text 2016002.001.006
AutoCAD SHX Text L-2
AutoCAD SHX Text 1"=40'
AutoCAD SHX Text
FJF
AutoCAD SHX Text
PEH
AutoCAD SHX Text
AutoCAD SHX Text Copyright, 2016
AutoCAD SHX Text Mabbett & Associates, Inc.
ABC
F
G
H I J
L
K
M
DE
up
LEGEND
Scientists I Engineers I Program Managers
Mabbett & Associates, Inc.
5 Alfred Circle Bedford, MA 01730-2318
T. 781-275-6050 - 800-877-6050 www.mabbett.com
ASBESTOS AND
LEAD SURVEY
PLAN 1st FLOOR
SANDY HOOK UNIT OF THE GATEWAY
NATIONAL RECREATION AREA SANDY HOOK, NEW JERSEY
HAZARDOUS MATERIALS SURVEY-BLDG. 65
AutoCAD SHX Text Pb-01
AutoCAD SHX Text Pb-02
AutoCAD SHX Text Pb-03
AutoCAD SHX Text 07A
AutoCAD SHX Text 15A,16A
AutoCAD SHX Text Pb-04
AutoCAD SHX Text 07B
AutoCAD SHX Text Pb-08
AutoCAD SHX Text
04C,05C(TR)
AutoCAD SHX Text 07C
AutoCAD SHX Text
04B,05B(TR)
AutoCAD SHX Text
04A,05A(TR)
AutoCAD SHX Text 15B,16B
AutoCAD SHX Text Pb-06
AutoCAD SHX Text Pb-07
AutoCAD SHX Text
01C**,02C(TR),03C(TR)02C(TR),03C(TR)
AutoCAD SHX Text 15C,16C
AutoCAD SHX Text
01B**,02B(TR),03B(TR)02B(TR),03B(TR)
AutoCAD SHX Text
01A*, 02*, 03A(TR)03A(TR)
AutoCAD SHX Text 06A,06B,06C
AutoCAD SHX Text Pb-05
AutoCAD SHX Text 08A
AutoCAD SHX Text
STOP POSITIVE SAMPLE FOR ASBESTOS
AutoCAD SHX Text
NO ASBESTOS DETECTED (NAD)
AutoCAD SHX Text
SAMPLE GREATER THAN 1% ASBESTOS
AutoCAD SHX Text
APPROXIMATE SAMPLE LOCATION
AutoCAD SHX Text 1,2
AutoCAD SHX Text
AutoCAD SHX Text 25**
AutoCAD SHX Text 25*
AutoCAD SHX Text 9"x9" FLOOR TILE MASTIC
AutoCAD SHX Text BOILER COMPONENTS, BOILER INSULATION, PIPE & FITTING INSULATION, FLUE PACKING AND DEBRIS ARE ACM.
AutoCAD SHX Text 9"x9" FLOOR TILE
AutoCAD SHX Text
TRACE <1% ASBESTOS
AutoCAD SHX Text
(TR)
AutoCAD SHX Text
BOILER ROOM
AutoCAD SHX Text FLASHINGS AND VAPOR BARRIER (ASSUMED) ASSOCIATED WITH SLATE SHINGLE ROOF CONTAINS ACM
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DWG. NO.
AutoCAD SHX Text
PROJ. NO.
AutoCAD SHX Text 2016002.001.006
AutoCAD SHX Text
PEH
AutoCAD SHX Text
MFD
AutoCAD SHX Text 1"=10'
AutoCAD SHX Text ASB/Pb-1
AutoCAD SHX Text
GRAPHIC SCALE
AutoCAD SHX Text
AutoCAD SHX Text
1 INCH= FEET
AutoCAD SHX Text
AutoCAD SHX Text 5'
AutoCAD SHX Text 10'
AutoCAD SHX Text 20'
AutoCAD SHX Text Copyright, 2016
AutoCAD SHX Text Mabbett & Associates, Inc.
dn
LEGEND
Scientists I Engineers I Program Managers
Mabbett & Associates, Inc.
5 Alfred Circle Bedford, MA 01730-2318
T. 781-275-6050 - 800-877-6050 www.mabbett.com
ASBESTOS AND
LEAD SURVEY
PLAN ATTIC
SANDY HOOK UNIT OF THE GATEWAY
NATIONAL RECREATION AREA SANDY HOOK, NEW JERSEY
HAZARDOUS MATERIALS SURVEY-BLDG. 65
AutoCAD SHX Text 14A,14B,14C
AutoCAD SHX Text 13A
AutoCAD SHX Text Pb-10
AutoCAD SHX Text Pb-09
AutoCAD SHX Text 13B
AutoCAD SHX Text 13C
AutoCAD SHX Text 10C,11C
AutoCAD SHX Text 08B,08C
AutoCAD SHX Text 11A
AutoCAD SHX Text 10B,11B
AutoCAD SHX Text 17A*,17B**,17C**
AutoCAD SHX Text 12A*,12B**,12C**
AutoCAD SHX Text 10A
AutoCAD SHX Text
09A(TR),09B,09C
AutoCAD SHX Text
STOP POSITIVE SAMPLE FOR ASBESTOS
AutoCAD SHX Text
NO ASBESTOS DETECTED (NAD)
AutoCAD SHX Text
SAMPLE GREATER THAN 1% ASBESTOS
AutoCAD SHX Text
APPROXIMATE SAMPLE LOCATION
AutoCAD SHX Text 1,2
AutoCAD SHX Text
AutoCAD SHX Text 25**
AutoCAD SHX Text 25*
AutoCAD SHX Text
INSULATING SLEEVE STOCK PILE (ACM)
AutoCAD SHX Text FLASHINGS AND VAPOR BARRIER (ASSUMED) ASSOCIATED WITH SLATE SHINGLE ROOF CONTAINS ACM
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DWG. NO.
AutoCAD SHX Text
PROJ. NO.
AutoCAD SHX Text 2016002.001.006
AutoCAD SHX Text
PEH
AutoCAD SHX Text
MFD
AutoCAD SHX Text 1"=10'
AutoCAD SHX Text ASB/Pb-2
AutoCAD SHX Text
GRAPHIC SCALE
AutoCAD SHX Text
AutoCAD SHX Text
1 INCH= FEET
AutoCAD SHX Text
AutoCAD SHX Text 5'
AutoCAD SHX Text 10'
AutoCAD SHX Text 20'
AutoCAD SHX Text Copyright, 2016
AutoCAD SHX Text Mabbett & Associates, Inc.
Project No. R2016002.001.006.002 S:\ADMINA\2016002 DHM Design\001\006\002\HAZMAT-BldgMatRpt-Bldg 65.docx
APPENDIX A
Summary of ACM Building Results
© 2017, Mabbett & Associates, Inc. Page 1 of 2 June 30, 2017 Project No. R2016002.001.006.002 S:\ADMINA\2016002 DHM Design\001\006\002\HAZMAT-BldgMatRpt-Bldg 65.docx
Summary of ACM Building Survey Results
Sample No.
Sample Location Description of Material PLM Result TEM Result
01A 1st Floor 9"x9" Floor Tile 2.9% Chrysotile
01B 1st Floor 9"x9" Floor Tile Positive Stop (Not
Analyzed)
01C 1st Floor 9"x9" Floor Tile
02A 1st Floor 9"x9" Floor Tile Mastic 0.46% Chrysotile 2.4% Chrysotile
02B 1st Floor 9"x9" Floor Tile Mastic 0.26% Chrysotile
02C 1st Floor 9"x9" Floor Tile Mastic <0.25% Chrysotile
03A 1st Floor Paper Under 9"x9" Floor Tile <0.25% Chrysotile <0.1% Chrysotile
03B 1st Floor Paper Under 9"x9" Floor Tile <0.25% Chrysotile
03C 1st Floor Paper Under 9"x9" Floor Tile <0.25% Chrysotile
04A 1st Floor Brown Sheet Flooring NAD NAD
04B 1st Floor Brown Sheet Flooring NAD
04C 1st Floor Brown Sheet Flooring NAD
05A 1st Floor Sheet Flooring Backing <0.25% Chrysotile <0.1% Chrysotile
05B 1st Floor Sheet Flooring Backing <0.25% Chrysotile
05C 1st Floor Sheet Flooring Backing 0.95% Chrysotile
06A 1st Floor Gypsum Wall Board NAD
06B 1st Floor Gypsum Wall Board NAD
06C 1st Floor Gypsum Wall Board NAD
07A 1st Floor Fiber Ceiling Panel NAD
07B 1st Floor Fiber Ceiling Panel NAD
07C 1st Floor Fiber Ceiling Panel NAD
08A Attic Paper Under Hardwood Floor NAD NAD
08B Attic Paper Under Hardwood Floor NAD
08C Attic Paper Under Hardwood Floor NAD
09A Attic Window Glazing Debris NAD 0.73% Anthophyllite
09B Attic Window Glazing Debris NAD
09C Attic Window Glazing Debris NAD
10A Attic Brick Cap Mortar NAD
10B Attic Brick Cap Mortar NAD
10C Attic Brick Cap Mortar NAD
11A Attic Brick Wall Mortar NAD
11B Attic Brick Wall Mortar NAD
11C Attic Brick Wall Mortar NAD
12A Attic Insulating Sleeve Stock Pile 80% Chrysotile
Project No. R2016002.001 006.002 S:\ADMINA\2016002 DHM Design\001\006\002\HAZMAT-BldgMatRpt-Bldg 65.docx
Sample No.
Sample Location Description of Material PLM Result TEM Result
12B Attic Insulating Sleeve Stock Pile
12C Attic Insulating Sleeve Stock Pile
13A Attic Corrugated Paper Debris NAD
13B Attic Corrugated Paper Debris NAD
13C Attic Corrugated Paper Debris NAD
14A Attic 1'x1' Ceiling Tile Stock Pile NAD
14B Attic 1'x1' Ceiling Tile Stock Pile NAD
14C Attic 1'x1' Ceiling Tile Stock Pile NAD
15A Exterior Window Casing Caulk NAD NAD
15B Exterior Window Casing Caulk NAD
15C Exterior Window Casing Caulk NAD
16A Exterior Window Glazing NAD NAD
16B Exterior Window Glazing NAD
16C Exterior Window Glazing NAD
17A Roof Black Flashing at Copper 7.2% Chrysotile
17B Roof Black Flashing at Copper
17C Roof Black Flashing at Copper
NOTES: NAD – No Asbestos Detected
Project No. R2016002.001.006.002 S:\ADMINA\2016002 DHM Design\001\006\002\HAZMAT-BldgMatRpt-Bldg 65.docx
APPENDIX B
Laboratory Reports and Chains-of-Custody
EMSL Analytical, Inc.
1056 Stelton Road Piscataway, NJ 08854
Tel/Fax: (732) 981-0550 / (732) 981-0551 http://www.EMSL.com / piscatawaylab@emsl.com
EMSL Order: 051702479
Customer ID: MABB78
Customer PO:
Project ID:
Attention: Michael Delaney Phone: (781) 275-6050
Mabbett & Associates, Inc. Fax: (781) 275-5651
5 Alfred Circle Received Date: 06/08/2017 2:50 PM
Bedford, MA 01730-2318 Analysis Date: 06/09/2017
Collected Date: 06/08/2017
R2016002.001.006Project:
Test Report: Asbestos Analysis of Non-Friable Organically Bound Materials by PLM via
EPA 600/R-93/116 section 2.3
Sample ID Description Appearance % Matrix Material % Non-Asbestos Fibers Asbestos Types
01A
051702479-0001
1st Floor - 9"x9" Floor Tile Gray
Non-Fibrous
Homogeneous
97.1 None Chrysotile2.9%
01B
051702479-0002
1st Floor - 9"x9" Floor Tile
Positive Stop (Not Analyzed)
01C
051702479-0003
1st Floor - 9"x9" Floor Tile
Positive Stop (Not Analyzed)
02A
051702479-0004
1st Floor - 9"x9" Floor Tile Black
Non-Fibrous
Homogeneous
99.5 None Chrysotile0.46%
02B
051702479-0005
1st Floor - 9"x9" Floor Tile Black
Non-Fibrous
Homogeneous
99.7 None Chrysotile0.26%
02C
051702479-0006
1st Floor - 9"x9" Floor Tile Black
Non-Fibrous
Homogeneous
100 None Chrysotile<0.25%
03A
051702479-0007
1st Floor - Paper Under
9"x9" Floor Tile
Black
Fibrous
Homogeneous
100 None Chrysotile<0.25%
03B
051702479-0008
1st Floor - Paper Under
9"x9" Floor Tile
Black
Fibrous
Homogeneous
100 None Chrysotile<0.25%
03C
051702479-0009
1st Floor - Paper Under
9"x9" Floor Tile
Black
Fibrous
Homogeneous
100 None Chrysotile<0.25%
04A
051702479-0010
1st Floor - Brown Sheet
Flooring
Gray/Black
Non-Fibrous
Homogeneous
100 None No Asbestos Detected
04B
051702479-0011
1st Floor - Brown Sheet
Flooring
Gray/Black
Non-Fibrous
Homogeneous
100 None No Asbestos Detected
04C
051702479-0012
1st Floor - Brown Sheet
Flooring
Gray/Black
Non-Fibrous
Homogeneous
100 None No Asbestos Detected
EMSL maintains liability limited to cost of analysis . This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis . This report contains data that is (are) not covered by the NVLAP accreditation. Samples received in good condition unless otherwise noted. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.
Samples analyzed by EMSL Analytical, Inc. Piscataway, NJ NYS ELAP 11423, NVLAP Lab Code 101048-2, NJ NELAC 12037
Initial report from: 06/14/2017 14:27:38
ASB_PLMEPANOB_0012_0002 Printed 6/14/2017 2:27:45PM Page 1 of 3
Tel/Fax: (732) 981-0550 / (732) 981-0551 http://www.EMSL.com / piscatawaylab@emsl.com
EMSL Order: 051702479
Customer ID: MABB78
Customer PO:
Project ID:
Attention: Michael Delaney Phone: (781) 275-6050
Mabbett & Associates, Inc. Fax: (781) 275-5651
5 Alfred Circle Received Date: 06/08/2017 2:50 PM
Bedford, MA 01730-2318 Analysis Date: 06/09/2017
Collected Date: 06/08/2017
R2016002.001.006Project:
Test Report: Asbestos Analysis of Non-Friable Organically Bound Materials by PLM via
EPA 600/R-93/116 section 2.3
Sample ID Description Appearance % Matrix Material % Non-Asbestos Fibers Asbestos Types
05A
051702479-0013
1st Floor - Sheet Flooring
Backing
Black
Non-Fibrous
Homogeneous
100 None Chrysotile<0.25%
05B
051702479-0014
1st Floor - Sheet Flooring
Backing
Black
Non-Fibrous
Homogeneous
100 None Chrysotile<0.25%
05C
051702479-0015
1st Floor - Sheet Flooring
Backing
Black
Non-Fibrous
Homogeneous
99.0 None Chrysotile0.95%
08A
051702479-0022
Attic - Paper Under Hard
Wood Floor
Brown
Non-Fibrous
Homogeneous
100 None No Asbestos Detected
08B
051702479-0023
Attic - Paper Under Hard
Wood Floor
Brown
Non-Fibrous
Homogeneous
100 None No Asbestos Detected
08C
051702479-0024
Attic - Paper Under Hard
Wood Floor
Brown
Non-Fibrous
Homogeneous
100 None No Asbestos Detected
09A
051702479-0025
Attic - Window Glazing
Debris
Gray
Non-Fibrous
Homogeneous
99.5 Fibrous_Other No Asbestos Detected0.49
09B
051702479-0026
Attic - Window Glazing
Debris
Gray
Non-Fibrous
Homogeneous
99.5 Fibrous_Other No Asbestos Detected0.48
09C
051702479-0027
Attic - Window Glazing
Debris
Gray
Non-Fibrous
Homogeneous
99.5 Fibrous_Other No Asbestos Detected0.53
15A
051702479-0043
Exterior - Window Casing
Caulk
Gray
Non-Fibrous
Homogeneous
100 None No Asbestos Detected
15B
051702479-0044
Exterior - Window Casing
Caulk
Gray
Non-Fibrous
Homogeneous
100 None No Asbestos Detected
15C
051702479-0045
Exterior - Window Casing
Caulk
Gray
Non-Fibrous
Homogeneous
100 None No Asbestos Detected
EMSL maintains liability limited to cost of analysis . This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis . This report contains data that is (are) not covered by the NVLAP accreditation. Samples received in good condition unless otherwise noted. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.
Samples analyzed by EMSL Analytical, Inc. Piscataway, NJ NYS ELAP 11423, NVLAP Lab Code 101048-2, NJ NELAC 12037
ASB_PLMEPANOB_0012_0002 Printed 6/14/2017 2:27:45PM Page 2 of 3
Tel/Fax: (732) 981-0550 / (732) 981-0551 http://www.EMSL.com / piscatawaylab@emsl.com
EMSL Order: 051702479
Customer ID: MABB78
Customer PO:
Project ID:
Attention: Michael Delaney Phone: (781) 275-6050
Mabbett & Associates, Inc. Fax: (781) 275-5651
5 Alfred Circle Received Date: 06/08/2017 2:50 PM
Bedford, MA 01730-2318 Analysis Date: 06/09/2017
Collected Date: 06/08/2017
R2016002.001.006Project:
Test Report: Asbestos Analysis of Non-Friable Organically Bound Materials by PLM via
EPA 600/R-93/116 section 2.3
Sample ID Description Appearance % Matrix Material % Non-Asbestos Fibers Asbestos Types
16A
051702479-0046
Exterior - Window Glazing White
Non-Fibrous
Homogeneous
100 None No Asbestos Detected
16B
051702479-0047
Exterior - Window Glazing White
Non-Fibrous
Homogeneous
100 None No Asbestos Detected
16C
051702479-0048
Exterior - Window Glazing White
Non-Fibrous
Homogeneous
100 None No Asbestos Detected
17A
051702479-0049
Roof - Black Flashing At
Copper
Brown
Non-Fibrous
Homogeneous
92.8 None Chrysotile7.2%
17B
051702479-0050
Roof - Black Flashing At
Copper
Positive Stop (Not Analyzed)
17C
051702479-0051
Roof - Black Flashing At
Copper
Positive Stop (Not Analyzed)
Analyst(s)
David Moody (26) Nicholas Maslowski, Laboratory Manager or other approved signatory
EMSL maintains liability limited to cost of analysis . This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis . This report contains data that is (are) not covered by the NVLAP accreditation. Samples received in good condition unless otherwise noted. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.
Samples analyzed by EMSL Analytical, Inc. Piscataway, NJ NYS ELAP 11423, NVLAP Lab Code 101048-2, NJ NELAC 12037
ASB_PLMEPANOB_0012_0002 Printed 6/14/2017 2:27:45PM Page 3 of 3
Tel/Fax: (732) 981-0550 / (732) 981-0551 http://www.EMSL.com / piscatawaylab@emsl.com
051702479EMSL Order:
Customer ID: MABB78
Customer PO:
Project ID:
Attention: Phone:Michael Delaney (781) 275-6050
Fax:Mabbett & Associates, Inc. (781) 275-5651
Received Date:5 Alfred Circle 06/08/2017 2:50 PM
Analysis Date:Bedford, MA 01730-2318 06/08/2017
Collected Date: 06/08/2017
Project: R2016002.001.006
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
06A
051702479-0016
None DetectedGypsum
Non-fibrous (Other)
75%
13%
Cellulose12%Brown/Gray
Fibrous
Homogeneous
1st Floor - Gypsum
Wall Board
06B
051702479-0017
None DetectedGypsum
Non-fibrous (Other)
80%
12%
Cellulose8%Brown/Gray
Fibrous
Homogeneous
1st Floor - Gypsum
Wall Board
06C
051702479-0018
None DetectedQuartz
Ca Carbonate
Gypsum
Non-fibrous (Other)
3%
15%
65%
5%
Cellulose12%Gray/Tan
Fibrous
Heterogeneous
1st Floor - Gypsum
Wall Board
07A
051702479-0019
None DetectedNon-fibrous (Other)12%Cellulose88%Brown/White
Fibrous
Homogeneous
1st Floor - Fiber
Ceiling Panel
07B
051702479-0020
None DetectedNon-fibrous (Other)12%Cellulose88%Brown/White
Fibrous
Homogeneous
1st Floor - Fiber
Ceiling Panel
07C
051702479-0021
None DetectedNon-fibrous (Other)10%Cellulose90%Brown
Fibrous
Homogeneous
1st Floor - Fiber
Ceiling Panel
10A
051702479-0028
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
30%
55%
13%
Cellulose2%Gray
Non-Fibrous
Homogeneous
Attic - Brick Cap
Mortar
10B
051702479-0029
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
35%
50%
11%
Cellulose4%Gray
Non-Fibrous
Homogeneous
Attic - Brick Cap
Mortar
10C
051702479-0030
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
38%
55%
7%
Cellulose<1%Gray
Non-Fibrous
Homogeneous
Attic - Brick Cap
Mortar
11A
051702479-0031
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
40%
50%
10%
Cellulose<1%Brown
Non-Fibrous
Homogeneous
Attic - Brick Wall
Mortar
11B
051702479-0032
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
40%
45%
13%
Cellulose2%Brown
Non-Fibrous
Homogeneous
Attic - Brick Wall
Mortar
11C
051702479-0033
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
35%
52%
13%
Tan
Non-Fibrous
Homogeneous
Attic - Brick Wall
Mortar
12A
051702479-0034
80% ChrysotileNon-fibrous (Other)12%Cellulose8%White
Fibrous
Homogeneous
Attic - Insulating
Sleeve Stock Pile
12B
051702479-0035
Positive Stop (Not Analyzed)Attic - Insulating
Sleeve Stock Pile
12C
051702479-0036
Positive Stop (Not Analyzed)Attic - Insulating
Sleeve Stock Pile
13A
051702479-0037
None DetectedNon-fibrous (Other)12%Cellulose88%Brown
Fibrous
Homogeneous
Attic - Corregated
Paper Debris
Initial report from: 06/14/2017 14:16:29
Page 1 of 2ASB_PLM_0008_0001 - 1.78 Printed: 6/14/2017 2:16 PM
Tel/Fax: (732) 981-0550 / (732) 981-0551 http://www.EMSL.com / piscatawaylab@emsl.com
051702479EMSL Order:
Customer ID: MABB78
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
13B
051702479-0038
None DetectedNon-fibrous (Other)12%Cellulose88%Brown
Fibrous
Homogeneous
Attic - Corregated
Paper Debris
13C
051702479-0039
None DetectedNon-fibrous (Other)10%Cellulose90%Brown
Fibrous
Homogeneous
Attic - Corregated
Paper Debris
14A
051702479-0040
None DetectedNon-fibrous (Other)12%Cellulose88%Brown/White
Fibrous
Homogeneous
Attic - 1'x1' Ceiling
Tile Stock Pile
14B
051702479-0041
None DetectedNon-fibrous (Other)12%Cellulose88%Brown/White
Fibrous
Homogeneous
Attic - 1'x1' Ceiling
Tile Stock Pile
14C
051702479-0042
None DetectedNon-fibrous (Other)10%Cellulose90%Brown
Fibrous
Homogeneous
Attic - 1'x1' Ceiling
Tile Stock Pile
Analyst(s)
Colin Slattery (13)
Susan Pollack (6)
Nicholas Maslowski, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. Piscataway, NJ NYS ELAP 11423, NVLAP Lab Code 101048-2, NJ NELAC 12037, Philadelphia 289
Initial report from: 06/14/2017 14:16:29
Page 2 of 2ASB_PLM_0008_0001 - 1.78 Printed: 6/14/2017 2:16 PM
Tel/Fax: (732) 981-0550 / (732) 981-0551 http://www.EMSL.com / piscatawaylab@emsl.com
EMSL Order: 051702479
Customer ID: MABB78
Customer PO:
Project ID:
Attention: Michael Delaney Phone: (781) 275-6050
Mabbett & Associates, Inc. Fax: (781) 275-5651
5 Alfred Circle Received Date: 06/08/2017 2:50 PM
Bedford, MA 01730-2318 Analysis Date: 06/12/2017
Collected Date: 06/08/2017
R2016002.001.006Project:
Test Report: Asbestos Analysis of Non-Friable Organically Bound Materials by TEM via
EPA/600/R-93/116 Section 2.5.5.1
Sample ID Description Appearance % Matrix Material % Non-Asbestos Fibers Asbestos Types
02A
051702479-0004
1st Floor - 9"x9" Floor Tile Black
Non-Fibrous
Homogeneous
97.6 None Chrysotile2.4%
03A
051702479-0007
1st Floor - Paper Under
9"x9" Floor Tile
Black
Fibrous
Homogeneous
100 None Chrysotile<0.1%
04A
051702479-0010
1st Floor - Brown Sheet
Flooring
Gray/Black
Non-Fibrous
Homogeneous
100 None No Asbestos Detected
05A
051702479-0013
1st Floor - Sheet Flooring
Backing
Black
Non-Fibrous
Homogeneous
100 None Chrysotile<0.1%
08A
051702479-0022
Attic - Paper Under Hard
Wood Floor
Brown
Non-Fibrous
Homogeneous
100 None No Asbestos Detected
09A
051702479-0025
Attic - Window Glazing
Debris
Gray
Non-Fibrous
Homogeneous
99.3 None Anthophyllite0.73%
15A
051702479-0043
Exterior - Window Casing
Caulk
Gray
Non-Fibrous
Homogeneous
100 None No Asbestos Detected
16A
051702479-0046
Exterior - Window Glazing White
Non-Fibrous
Homogeneous
100 None No Asbestos Detected
Analyst(s)
Susan Pollack (8) Nicholas Maslowski, Laboratory Manager or other approved signatory
This laboratory is not responsible for % asbestos in total sample when the residue only is submitted for analysis. The above report relates only to the items tested. This report may not be reproduced, except in full, without written approval by EMSL Analytical , Inc. Samples received in good condition unless otherwise noted. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.
Samples analyzed by EMSL Analytical, Inc. Piscataway, NJ NYS ELAP 11423
Initial report from: 06/14/2017 14:16:27
ASB_PLMEPANOB_0012_0002 Printed 6/14/2017 2:16:45PM Page 1 of 1
OrderID: 051702479
Client Sample Description ConcentrationLab ID Analyzed Lead
Collected
EMSL Analytical, Inc.
200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (856) 303-2500 / (856) 786-5974 http://www.EMSL.com cinnaminsonleadlab@emsl.com
Attn: Michael Delaney Mabbett & Associates, Inc.
5 Alfred Circle Bedford, MA 01730-2318
Received: 06/09/17 9:00 AM
R2016002.001.006 / Forthood Building 65- Lead Paint Chips
Fax: (781) 275-5651 Phone: (781) 275-6050
Project:
6/8/2017Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
201705688 CustomerID: MABB78 CustomerPO:
ProjectID:
EMSL Order:
Site: 1st Floor, Metal Panel (Gray) 201705688-0001Pb-01 0.28 % wt6/12/20176/8/2017
Site: 1st Floor, Metal Panel (White) 201705688-0002Pb-02 0.24 % wt6/12/20176/8/2017
Site: 1st Floor, Brick Wall (White) 201705688-0003Pb-03 11 % wt6/12/20176/8/2017
Site: 1st Floor, Window Casing (White) 201705688-0004Pb-04 6.3 % wt6/10/20176/8/2017
Site: 1st Floor, Wood Watt (White) 201705688-0005Pb-05 1.1 % wt6/10/20176/8/2017
Site: 1st Floor, Metal Pipe (White) 201705688-0006Pb-06 0.34 % wt6/10/20176/8/2017
Site: 1st Floor, Metal Radiator (White) 201705688-0007Pb-07 0.29 % wt6/10/20176/8/2017
Site: 1st Floor, Wood Flooring (Gray) 201705688-0008Pb-08 0.33 % wt6/10/20176/8/2017
Site: Attic, Wood Window (White) 201705688-0009Pb-09 0.50 % wt6/10/20176/8/2017
Site: Attic, Wood Wall (Gray) 201705688-0010Pb-10 0.12 % wt6/10/20176/8/2017
Phillip Worby, Lead Laboratory Manager or other approved signatory
Test Report ChmSnglePrm/nQC-7.32.3 Printed: 6/13/2017 5:36:06 PM
*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.
Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Cinnaminson, NJ NELAP Certifications: NJ 03036, NY 10872, PA 68-00367, AIHA-LAP, LLC ELLAP 100194, A2LA 2845.01
Initial report from 06/13/2017 17:36:06 http://www.EMSL.com mailto:cinnaminsonleadlab@emsl.com
OrderID: 201705688
OrderID: 201705688
Project No. R2016002.001 006.002 S:\ADMINA\2016002 DHM Design\001\006\002\HAZMAT-BldgMatRpt-Bldg 65.docx
APPENDIX C
Project Photo-Log
Project No. R2016002.001 006.002 S:\ADMINA\2016002 DHM Design\001\006\002\HAZMAT-BldgMatRpt-Bldg 65.docx
Boiler Room
1st Floor – 9” x 9” Floor Tile and Mastic
Project No. R2016002.001 006.002 S:\ADMINA\2016002 DHM Design\001\006\002\HAZMAT-BldgMatRpt-Bldg 65.docx
Attic - Insulating Sleeve Stock Pile in Attic
Black Roof Flashing and Assumed Slate
Roofing Underlayment
| 2-Figures All.pdf |
| a-Figure L-1_Site Locus Map |
| Sheets and Views |
| L-1 |
| b-Figure L-2_Site Plan |
| Sheets and Views |
| L-2 |
| c-Figure ASB Pb-1 BUILDING #65 1ST FLOOR |
| Sheets and Views |
| BUILDING #65 FIRST FLOOR |
| d-Figure ASB Pb-2 BUILDING #65 ATTIC |
| Sheets and Views |
| BUILDING #65 ATTIC |
| 3-App B All.pdf |
| a-ACM |
| 1 -PLM NOB Results |
| 2- PLM Results |
| 3- TEM Results |
| 4- Mabbett coc |