GATE_201049B_Reference_Drawings.pdf

PDF 13 MB Posted

Attached to
GATE - Repair Park Telecommunications Federal contract opportunity
Solicitation number
p15ps00589
Issued by
Department of the Interior National Park Service National Office

About this file

Reference Drawings

View the file

Other files for this federal contract opportunity

Other files attached to GATE - Repair Park Telecommunications, newest first.
File Type Posted
SF-30_Amend_3.pdf PDF
QandA_Amend_3.pdf PDF
Amend_0002_SF-30_P15PS00589.pdf PDF
Amendment_0002_Pre-proposal_mtg_notes.pdf PDF
Amendment_0002_Description_of_Changes.pdf PDF
1_-_Amendment_000001_P15PS00589 _SF-30.pdf PDF
2_-_Amendment_000001_P15PS00589 _Attachment_1 _revised_1040.docx DOCX document
3_-_Amendment_000001_P15PS00589 _Preproposal_Site_Visit_Attendees.pdf PDF
5_-_Wage_Determination _NY3.txt TXT text file
2_-_SF-1442.pdf PDF
4_-_Proposal_Submission_Package.docx DOCX document
1_-_RFP_Cover_Letter.doc DOC document
GATE_201049B_Drawings_Sheets_26-28.pdf PDF
GATE_201049B_Drawings_Sheets_35-39.pdf PDF
GATE_201049B_Drawings_Sheets_1-25.pdf PDF
7_-_Contract_Price_Schedule_-_Blank.xlsx XLSX spreadsheet
3_-_Clauses_ _Provisions.docx DOCX document
GATE_201049B_Drawings_Sheets_32-34.pdf PDF
GATE_201049B_Project_Scope.pdf PDF
5_-_Wage_Determination _NJ58.txt TXT text file
6_-_Map _Preproposal_Site_Visit_Location.pdf PDF
GATE_201049B_Drawings_Sheets_29-31.pdf PDF
Presolicitation_Notice _Revised_6-29-15.doc DOC document
Show all 23

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OAKWOOD BEACH SEWAGE

TREATMENT PLANT

MAIN PUMP HOUSE

4028,651-653+654T+ 655-687+688T+ 689-691+692T+

693-700+100XD

25XD+1063,626-700

25XD+1063,626-700

2005 9AESUN-1

A4208,1-900+ 1063,1-100+

401-600+25XD+

1063,626-700+

PGL04A,1201-1275+1XD+

PGL04A,1277-1294+1XD+

PGL04A,1296-1297+1XD+

PGL04A,1299+1XD+

TH'A',1-400

A

1063,1-100+

401-600+25XD+

1063,626-700+

PGL04A,1201-1275+1XD+

PGL04A,1277-1294+1XD+

PGL04A,1296-1297+1XD+

PGL04A,1299+1XD+

TH'A',1-200+

A4208,1-2000

B

50XD

4028,651-653+654T+ 655-687+688T+ 689-691+692T+

693-700+100XD

SEE X

X

4028,651-653+654T+ 655-687+688T+ 689-691+692T+ 693-700

C

2005 9AEVNU-1

Fund Source: Gross Project Construction Cost:

Predesign Begin Date:

FY of Const. Funding

Park:

State: Region:

Type of Building

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

SS Prereq 1 Construction Activity Pollution Prevention

Y N/A Project involves interior work only

SS Credit 1 Site Selection Y 1 Land is public parkland (Parkland Exception)

SS Credit 2 Development Density & Community Connectivity

Y 5 Renovation occurs on a previously developed site

SS Credit 3 Brownfield Redevelopment N 1 Site is not contaminated

SS Credit 4.1 Alternative Transportation, Public Transportation Access

Y 1 Renovation is located within 1/4 mile walking distance of a public bus line

SS Credit 4.2 Alternative Transportation, Bicycle Storage & Changing Rooms

Y 1 Bicycle racks, shower and changing facilities are curerently provided

SS Credit 4.3 Alternative Transportation, Low-Emitting & Fuel-Efficient Vehicles

Y 1 preferred parking for low-emitting, fuel efficient vehicles will be provided

Project Type

Description:

Park/PMIS: GATE-201049B

Not Certified/Missing Prereq.

Replace Water Damaged Telecommunication Infrastructure

Please Input CRV in block to the right for the building(s) in this project

0% 0%

Missed Prereq.

Gross Non Building (i.e. Site) Cost:

67% 0%

If Renovation, Exist. Bldg. CRV

Sustainability Features PMIS Submission Predesign Schematic Design Design Development

HDR, Inc. GATE

Missed Prereq.

Not Certified/Missing Prereq.

Gross Building Construction Cost:

Missed Prereq. #VALUE! Missed Prereq.

LEED Certification Level Not Certified/Missing Prereq. Not Certified/Missing Prereq. #VALUE!

Construction

0%% Federal Regulations Achieved

Sustainable Sites (SS) Maximum LEED NC 2009 Credits: 26

Construction Documents

Missed Prereq.

Architect/Engineer Firm:

Date: May 28, 2015

NPS Project Sustainability Checklist Building and Non-Building Projects

(For New Construction or Renovation) LEED 2009 Edition

Project Title: Repair Park Telecommunications Damaged by Hurricane Sandy

Not Certified/Missing Prereq.

Total LEED-NC Credits

Building Size (Square Feet)

0%

Form E 62 (5/26/10) 1

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Sustainability Features PMIS Submission Predesign Schematic Design Design Development Construction Construction Documents

SS Credit 4.4 Alternative Transportation, Parking Capacity

Y 1 No new parking is planned for this renovation

SS Credit 5.1 Site Development, Protect or Restore Habitat

Y 1 Construction boundaries will be established ti minimize disturbance of the existing site

SS Credit 5.2 Site Development, Maximize Open Space

Y 1 The renovation is planned to be located within the existing building footprint

SS Credit 6.1 Stormwater Design, Quantity Control (See EISA Section 438)

Y 1 Reuse of stormwater will be investigated for custodial and landscape irrigation

SS Credit 6.2 Stormwater Design, Quality Control (See EISA Section 438)

Y 1 Recycling of rainwater will be investigated

EISA 2007,

Section 438 Protect Hydrology Y N/A Project involves no site work

SS Credit 7.1 Heat Island Effect, Non-Roof Y 1 High albedo coatings and integral colorants will be used for re-roofing

SS Credit 7.2 Heat Island Effect, Roof Y 1 The use of high-albedo roofs will be investigated

SS Credit 8 Light Pollution Reduction Y 1 Interior light fixtures will not produce light spillage through windows

2006 NPS Mgmt Policies (Para.

4.9) Soundscape Preservation Y N/A

Exterior noise producing equipment (air handelers) willl be quieter than ambient noise levels

2006 NPS Mgmt Policies (Para.

4.10) Dark Sky Preservation Y N/A No new exterior lighting is proposed

Missed Prereq.

Missed Prereq. 18 Missed

Prereq.

Missed Prereq.

Missed Prereq.LEED-NC Subtotal

Water Efficiency (WE) Maximum LEED NC 2009 Credits: 10

PMIS Submission Predesign Schematic Design Design Development Construction Documents Construction

Form E 62 (5/26/10) 2 credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Sustainability Features PMIS Submission Predesign Schematic Design Design Development Construction Construction Documents

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

WE Prereq 1 Water Use Reduction, 20% Reduction (see Guiding Principle III ‐ Protect and Conserve Water)

N N/A Plumbing fixtures will be utilized for water use reduction

WE Credit 1

Water Efficient Landscaping, Reduce by 50% (see Guiding Principle III ‐ Protect and Conserve Water)

N 0 No exterior landscaping is planned

WE Credit 1 (cont'd)

Water Efficient Landscaping, No Potable Use or No Irrigation

Y 2 Use of recycled rainwater will be investigated

WE Credit 2 Innovative Wastewater Technologies

Y 2 Use of recycled water will be investigated

NPS Policy Water Metering Y N/A Building has an existing water meter

EPACT 2005,

Section 109

Water Used for Energy Conservation

Y N/A The use of water energy conservation systems will be investigated

WE Credit 3 Water Use Reduction (30%, 35%, 40%)

Y 2 Plumbing fixtures will be utilized for water use reduction

Missed Prereq.

Missed Prereq.

Missed Prereq.

Missed Prereq.

Missed Prereq.

Missed Prereq.

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

EA Prereq 1

Fundamental Commissioning of the Building Energy Systems * (see Guiding Principle I ‐ Employ Integrated Design Principles)

Y N/A Fundemental commissioni ng will be utilized for this renovation

EA Prereq 2 Minimum Energy Performance (see Guiding Principle II Optimize Energy Performance)

Y N/A Energy performance will be improved by 5% for the renovated area

EA Prereq 3

Fundamental Refrigerant Management (see Guiding Principle V ‐ Reduce Environmental Impact of Materials)

Y N/A Equipment that contains Ozone depleting compounds will not be utilized

Design Development Construction Documents

LEED-NC Subtotal

Energy & Atmosphere (EA) Maximum LEED NC 2009 Credits: 35

Sustainability Features PMIS Submission Predesign Schematic Design Construction

Sustainability Features

Form E 62 (5/26/10) 3 credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Sustainability Features PMIS Submission Predesign Schematic Design Design Development Construction Construction Documents

EA Credit 1

Optimize Energy Performance:** (Federal Regulations require 30% for New Construction and 20% for Existing Building Renovation. Note that this automatically equates to 10 Points for New Construction and 7 Points for Existing Building Renovation.) (see Guiding Principle II ‐ Optimize Energy Performance)

Y 7

Energy performance will be improved by 20% over ASHRAE 90.1 for the renovated area

EISA 2007,

Section 433

Reduce Fossil Fuel Derived Energy

N N/A Renovation is less than $2.5M

EO 13423, Sec.

2.(h)

Energy Efficient Electronic Products (Select EPEAT) (Predominantly relates to purchases of desktop/laptop computers and peripherals)

Y N/A All electronics will be energy efficient

CFR Title 10, Part 436.4

Procure Energy Star or FEMP designated products

Y N/A New fixtures will be Energy Star of FEMP designated products

EPACT 2005,

Section 104

Premium Efficiency Electric Motors

N N/A Project is not a major renovation

EISA 2007,

Section 523

On-Site Renewable Energy*** Solar Thermal for Hot Water (Choose NA if proven not life cycle cost effective)

N N/A Project is not a major renovation

EA Credit 2 On-Site Renewable Energy*** 1%-13% Renewable Energy

Y 2 Renewable alternatives will be investigated

EA Credit 3

Enhanced Commissioning (required for projects with building size > 5,000 sf) (see Guiding Principle I ‐ Employ Integrated Design Principles)

Y 2 Enhanced Commissioning will be investigated

EA Credit 4 Enhanced Refrigerant Management (see Guiding Principle V ‐ Reduce Environmental Impact of Materials)

Y 2 Refrigerants will not be utilized

EA Credit 5 Measurement & Verification (see Guiding Principle II ‐ Optimize Energy Performance)

Y 3 M&V measures will be utilized

EA Credit 6 Green Power Y 2 Green power options will be investigated

Form E 62 (5/26/10) 4 credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Sustainability Features PMIS Submission Predesign Schematic Design Design Development Construction Construction Documents

Missed Prereq.

Missed Prereq. 18 Missed

Prereq.

Missed Prereq.

Missed Prereq.

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

MR Prereq 1 Storage & Collection of Recyclables

Y N/A Storage and collection of recyclables is currently in use at the facility

MR Credit 1.1 Building Reuse, Maintain Existing Walls, Floors & Roof

Y 3 The exterior envelope will be resued, with improvements, for this project

MR Credit 1.2 Building Reuse, Maintain Interior Nonstructural Elements

N 0 Interior materials will be new

MR Credit 2

Construction Waste Management, Divert 50% from Disposal (see Guiding Principle V ‐ Reduce Environmental Impact of Materials)

Y 1 A waste management plan will be developed

MR Credit 2 (cont'd)

Construction Waste Management, Divert 75% from Disposal

Y 1 A waste management plan will be developed

MR Credit 3 Materials Reuse N 0 Reuse of listed materials will not be utilzed

MR Credit 4

Recycled Content, 10% (post‐ consumer + ½ pre‐consumer). Use EPA's CPG for designated products to use)

Y 1 Materials with 10% recycled content will be utilized

MR Credit 4 Recycled Content, 20% (post-consumer + ½ pre-consumer)

Y 1 Materials with 20% recycled content will be utilized

MR Credit 5 Regional Materials, Extracted, Processed & Manufactured Regionally

Y 2 Regional materials will be utilized

EO 13423, Sec.

2.(d)

Biopreferred Products Y N/A Biopreffered materials will be utilizied

Predesign Schematic Design Design Development Construction Documents

LEED-NC Subtotal

Materials & Resources (MR) Maximum LEED NC 2009 Credits: 14

Sustainability Features PMIS Submission Construction

Form E 62 (5/26/10) 5 credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Sustainability Features PMIS Submission Predesign Schematic Design Design Development Construction Construction Documents

MR Credit 6 Rapidly Renewable Materials Y 1 Rapidly renewable materials will be utilized

MR Credit 7 Certified Wood (see Guiding Principle V ‐ Reduce Environmental Impact of Materials)

Y 1 Certified lumber will be utilized

Missed Prereq.

Missed Prereq. 11 Missed

Prereq.

Missed Prereq.

Missed Prereq.

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

EQ Prereq 1 Minimum IAQ Performance (See Guiding Principle IV, Enhance Indoor Environmental Quality)

Y N/A The renovation will meet

ASHRAE 62.1-2007

EQ Prereq 2 Environmental Tobacco Smoke (ETS) Control

Y N/A The facility is designated as smoke free

EQ Credit 1 Outdoor Air Delivery Monitoring

Y 1 Outdoor air monitoring will be provided

EQ Credit 2 Increased Ventilation Y 1 Ventilation rates will meet

ASHRAE 62.1-2007

EQ Credit 3.1

Construction IAQ Management Plan, During Construction (See Guiding Principle IV, Enhance Indoor Environmental Quality)

Y 1 An IAQ Management Plan will be utilized during construction

EQ Credit 3.2

Construction IAQ Management Plan, Before Occupancy (See Guiding Principle IV, Enhance Indoor Environmental Quality)

Y 1 All systems will be flushed out prior to occupance

EQ Credit 4.1

Low‐Emitting Materials, Adhesives & Sealants (See Guiding Principle IV, Enhance Indoor Environmental Quality)

Y 1 All sealants will be low VOC

EQ Credit 4.2

Low‐Emitting Materials, Paints & Coatings (See Guiding Principle IV, Enhance Indoor Environmental Quality)

Y 1 All paints and coatings will be low VOC

Schematic Design Design Development Construction Documents Construction Sustainability Features

LEED-NC Subtotal

Indoor Environmental Quality (EQ) Maximum LEED NC 2009 Credits: 15

PMIS Submission Predesign

Form E 62 (5/26/10) 6 credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Sustainability Features PMIS Submission Predesign Schematic Design Design Development Construction Construction Documents

EQ Credit 4.3

Low‐Emitting Materials, Flooring Materials (See Guiding Principle IV, Enhance Indoor Environmental Quality)

Y 1 All flooring systems will be low

VOC

EQ Credit 4.4 Low-Emitting Materials, Composite Wood & Agrifiber Products

Y 1 All lumber will be low VOC

EQ Credit 5 Indoor Chemical & Pollutant Source Control

Y 1 Indoor chemical and pollutant source controls will be utilized

MOU Guiding Principles & EO

13423 Moisture Control Y N/A

Building enevelope will be enhanced to comply with moisture control requirements

EQ Credit 6.1 Controllability of Systems, Lighting (See Guiding Principle IV, Enhance Indoor Environmental Quality)

Y 1 Interior lighting controls will be utilized

EQ Credit 6.2 Controllability of Systems, Thermal Comfort

Y 1 Thermal comfort controls will be utilized

EQ Credit 7.1 Thermal Comfort, Design (See Guiding Principle IV, Enhance Indoor Environmental Quality)

N 0 Project is not a major renovation

EQ Credit 7.2 Thermal Comfort, Verification Y 1

Buildng occupants will be surveyed 6to 18 months after occupancy regarding thermal comfort

EQ Credit 8.1

Daylight & Views, Daylight 75% of Spaces (See Guiding Principle IV, Enhance Indoor Environmental Quality)

Y 1 Daylight controls will be utilized

EQ Credit 8.2 Daylight & Views, Views for 90% of Spaces

Y 1 Vision glazing will provided for occupied spaces (Exception - Dispatch Room)

Missed Prereq.

Missed Prereq. 14 Missed

Prereq.

Missed Prereq.

Missed Prereq.

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

ID Credit 1.1 Innovation in Design: Provide Specific Title

Innovation & Design Process (ID) Maximum LEED NC 2009 Credits: 6

Sustainability Features Construction

LEED-NC Subtotal

Design Development Construction DocumentsSchematic DesignPMIS Submission Predesign

Form E 62 (5/26/10) 7 credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Y, N, NA Points Concisely explain how credit/requirement is met at this milestone:

Sustainability Features PMIS Submission Predesign Schematic Design Design Development Construction Construction Documents

ID Credit 1.2 Innovation in Design: Provide Specific Title

ID Credit 1.3 Innovation in Design: Provide Specific Title

ID Credit 1.4 Innovation in Design: Provide Specific Title

ID Credit 1.5 Innovation in Design: Provide Specific Title

ID Credit 2 LEED® Accredited Professional

0 0 0 0 0 0

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

RP Credit 1.1 Regional Priority Credit:

Region Defined

RP Credit 1.2 Regional Priority Credit:

Region Defined

RP Credit 1.3 Regional Priority Credit:

Region Defined

RP Credit 1.4 Regional Priority Credit:

Region Defined

0 0 0 0 0 0

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

Y, N, N/A Points Concisely explain how credit/requirement is met at this milestone:

MOU Guiding Principles & EO 13423 (pg. 3)

Complete Integrated Design Narrative During Predesign Only

N N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

LEED Certification Rating System Certified: 40-49 points, Silver: 50-59 points, Gold: 60-79 points, Platinum: 80+ points

For more information on LEED Certification and credits, visit www.usgbc.org

*** The federal requirement (from EISA 2007) that relates to these LEED‐NC credits is "Where life cycle cost effective, design systems to provide not less than 30 percent of the hot water demand through the installation and use of solar hot water heaters." The LEED credits for this item stipulates a percentage of total energy consumption to be provided by on site renewable sources. In some cases meeting the federal requirement will also meet the LEED requirement for these credits.

Sustainability Features PMIS Submission

* For new buildings of 5,000 GSF or more and major renovations to buildings greter than or equal to 5,000 GSF, contract with an independent Commissioning Authority and comply with ASHRAE 0‐2005, "The Commissioning Process". For smaller projects, comply with the requirements of LEED NC 2009, EA Prerequisite 1, "Fundamental Commissioning of the Building Energy Systems" (which allows the commissioning authority to be an employee of the design firm).

** For new building projects of 5,000 GSF or more, perform whole building energy simulation(s) in accordance with ASHRAE 90.1, 2007 (or IECC 2006 for residential) to show performance at least 30% better (20% for major renovations) than a code compliant similar building. If it can be shown that meeting the 30% performance standard for new construction (or 20% for major renovations) is not life cycle cost effective (over 40 years ‐ not 25 years per a recent regulatory change) then the project must incorporate the maximum energy savings that can be shown to be life cycle cost effective. For new building projects with a lower net construction value, an alternative method is to meet or exceed the minimum requirements prescribed by the ASHRAE Advanced Energy Design Guide (a much simpler prescriptive method for achieving the target) appropriate for the project's building. For buildings without an appropriate Advanced Energy Design Guide perform whole building energy simulation(s) in accordance with ASHRAE 90.1, 2007 (or IECC 2006 for residential).

Schematic Design

Regional Priority (RP) Maximum LEED NC 2009 Credits: 4

Design Development

Fulfillment of Guiding Principles for HPSB completes 18 LEED NC credits and 6 prerequisites.

Schematic Design Design Development Construction Documents

Construction Documents Construction

LEED-NC Subtotal

Construction

Non-LEED-NC Federal Requirements Maximum LEED NC 2009 Credits: 26

Predesign

LEED-NC Subtotal

Sustainability Features PMIS Submission Predesign

Form E 62 (5/26/10) 8

File details come from the government source that posted it. Updated .