P03 SSJ 3a - 695-20-105 Building Automation HVAC Cntrls_SingleSourceJustification_MPT-SAT.docx
DOCX document 28 KB Posted
- Attached to
- Z2DA--695-20-105: Upgrade Electrical System Area 2 Federal contract opportunity
- Solicitation number
- 36C25222B0010
About this file
This single source justification document from the Department of Veterans Affairs requests approval to procure Johnson Controls Metasys building automation and HVAC control system materials from the sole-source provider, Johnson Controls. The VA facility in Milwaukee, Wisconsin requires a new control panel and controllers costing approximately $6,500 to be installed and integrated into the campus-wide Johnson Controls Metasys system already in use. Using an incompatible system would necessitate installation of new front-end and remote workstations as well as new software and programming, increasing maintenance costs and requiring separate spare parts inventory. Only the Johnson Controls product ensures complete compatibility across the VA campus and avoids introducing a second unrelated HVAC control system. Market research found no other systems compatible with the VA's standards. The contracting officer certified the single source procurement is properly justified according to FAR 13.106-1.
The related federal contract opportunity is a solicitation from the VA's Veterans Health Administration VISN 12 for upgrade work on the electrical system in Area 2 at the Clement J. Zablocki VA Medical Center in Milwaukee, Wisconsin, where the building automation project documented above will take place.
View the file
Other files for this federal contract opportunity
Show all 26
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VHAPM Part 813.106 Simplified Acquisition Procedures: Soliciting from a Single Source Attachment 1: Single Source Justification for SAP under the SAT
DEPARTMENT OF VETERANS AFFAIRS
Justification for Single Source Awards IAW FAR 13.106-1 For Over Micro-Purchase Threshold but Not Exceeding the SAT ($250K)
Acquisition Plan Action ID: 36C252-xx-AP-xxxx
1. Contracting Activity: Department of Veterans Affairs, Great Lakes Acquisition Center, NCO 12, 115 South 84th Street, Milwaukee, WI 53214. Requesting Activity: Department of Veterans Affairs, VISN 12, Clement J. Zablocki VA Medical Center, 5000 W. National Avenue, Milwaukee WI 53295. Purchase Request (2237) number: 695‐XX‐X-XXXX-XXXX
2. Brief Description of Supplies/ Services required and the intended use/Estimated Amount:
The equipment to be installed will be monitored and controlled by Johnson Controls Metasys Building Automation and HVAC Control System. A new panel and necessary controllers will be installed and tied into the existing system, to be monitored and controlled by VA’s ‘Graphics’ shop.
The estimated expected cost for Johnson Controls Metasys material is $ 6,500 .
3. Unique characteristics that limit availability to only one source, with the reason no other supplies or services can be used:
This product, the Johnson Controls Metasys Building Automation and HVAC Control System, is the only product that allows for a single HVAC control system for the Milwaukee facility. Johnson Controls Metasys control system is the campus-wide building and HVAC control System. An incompatible system may require installation of new “front-end” and remote workstations as well as new software and programming. Additionally, installation of components that match the existing building automation system minimizes maintenance costs and bench stock requirements. It is necessary to match the existing system to ensure there are no interface problems, impacts to patient safety and familiarity of the product to the staff and maintenance personnel. This is the only way to ensure complete compatibility and that the campus will not have two HVAC control systems on the Milwaukee campus.
4. Description of market research conducted and results or statement why it was not conducted:
We have conducted research into other Building Automation and HVAC Control systems and have found that they are not compatible with our standard. The other products on the market would require additional cost to maintain within the facility
5. Contracting Officer's Certification: Purchase is approved in accordance with FAR13.106-1(b). I certify that the foregoing justification is accurate and complete to the best of my knowledge and belief.
| ____________________________ | ________________________ |
| Name | Date |
Title
VHAPM Part 813.106 Page 1 of 1 Original Date: 08/30/17 Revision 02 Eff Date: 03/31/2020