ORL1025.014-VOLUSIA_COUNTY_DELAND_IT_RESTROOM_AR-IN_BID&CONSTRUCT_S&S.pdf
PDF 13 MB Posted
- Attached to
- Deland IT Restroom Energy Conservation Measures
- Solicitation number
- 25-B-90LL
- Issued by
- Volusia County, Florida
About this file
This document is a comprehensive architectural bid and construction set for the Volusia County DeLand IT Restroom Energy Conservation Measures project located at 119 West Indiana Avenue in DeLand, Florida. The project involves a renovation of four existing restroom spaces across two floors (two men's and two women's restrooms), with the primary objectives of updating the layout to improve ADA accessibility and functionality for staff. The scope of work includes selective interior demolition, installation of new toilet partitions, replacement of plumbing and electrical fixtures, new finishes (floors, walls, ceilings), and updates to toilet accessories. The project is categorized as a Level 2 alteration under the Florida Building Code, with work concentrated on reconfiguring spaces, adding/eliminating doors, and upgrading building systems.
The architectural plans detail specific design elements including porcelain tile walls and floors, solid surface toilet partitions, new ceiling systems, and ADA-compliant fixtures. The project will use materials from manufacturers like Crossville (tiles), Bobrick (accessories), and Hi-Macs (solid surfaces). Total project area spans both the first and second floors of the building, with each floor having approximately 7,881 and 4,000 square feet respectively. The design emphasizes energy conservation, accessibility, and modern restroom functionality, with careful attention to maintaining the existing building's structural integrity and aesthetic. The bid and construct set is dated February 24, 2025, with Raymond Engineering Georgia, Inc. serving as the architectural and engineering firm responsible for the design.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OWNER
VOLUSIA COUNTY
119 WEST INDIANA AVENUE
DELAND, FLORIDA, 32720
PHONE: 386-736-5935 FAX:386-736-5972
WWW.VOLUSIA.ORG OR PURCHASING@VOLUCIA.ORG
POINT OF CONTACT: KAMRON GARDNER
ELECTRICAL
RAYMOND
9100 CONROY WINDERERE RD.
SUITE 200
WINDEREMERE, FLORIDA 34789
HTTP://RAYMOND.GLOBAL
770-483-9592
POINT OF CONTACT: FLOYD KEELS
PLUMBING
RAYMOND
9100 CONROY WINDERERE RD.
SUITE 200
WINDEREMERE, FLORIDA 34789
HTTP://RAYMOND.GLOBAL
770-483-9592
POINT OF CONTACT: CHARLES HANNING
ARCHITECT
RAYMOND
9100 CONROY WINDERERE RD.
SUITE 200
WINDEREMERE, FLORIDA 34789
HTTP://RAYMOND.GLOBAL
770-483-9592
POINT OF CONTACT: JOSE R. MCCAUSLAND
MECHANICAL
RAYMOND
9100 CONROY WINDERERE RD.
SUITE 200
WINDEREMERE, FLORIDA 34789
HTTP://RAYMOND.GLOBAL
770-483-9592
POINT OF CONTACT: CHARLES HANNING
PROJECT AREA
PLAN N
TRUE
NORTH
PROJECT AREA
PLAN N
TRUE
NORTH
R A
Y M
O N
D
RAYMOND
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
VOLUME:
1035 GREEN STREET SE, SUITE A
CONYERS, GA 30012
G
E
C
A
F
D
B
H
1 3 5 7 92 4 6 8 10 11
T H
E
IN
F O
R M
A T
IO
N
C O
N T
A
IN
E D
O N
T H
IS
D
R A
W
IN
G
IS
T H
IN
T
E
LL
E C
T U
A L
A N
D P
H Y
S
IC
A L
C O
P Y
R
IG
H T
P R
O P
E R
T Y
F
R A
Y M
O N
D E
N G
IN
E
E R
IN
G
G E
O R
G
IA
IN
C
A
N D
M A
Y N
B
D U
P
LI
C A
T E
D
IN
P A
R T
O
W
O
LE
IN
A
N Y
M A
N N
C
LU
D
IN
G
IM
A
G
IN
G
E
LE
C T
R O
N
IC
S C
A N
N
IN
G , O
G
A P
H
IC
R E
P R
O D
U C
T
IO
N
Y
N D
T R
A N
S F
E R
E , W
IT
H
O U
E E
X P
R E
S S
W R
IT
T
P
R M
IS
S
IO
N
O F
T H
E A
U T
H O
R
R A
Y M
O N
D E
N G
IN
E
E R
IN
G
G E
O R
G
IA
IN
C
A
LL
R
IG
H
S
S E
R V
E D
, Y E
A R
A S
D A
T E
D
R A
Y M
O N
D P
R O
J E
C T
N O
C
O P
Y R
IG
H
T
G
R E
E N
S T
R E
E T
S E
S
U
IT
E A
C O
N Y
E R
S G
E O
R G
IA
-6
-2
R a ym o n d
E n g in ee ri n g
G eo rg ia
, I N
C
SHEET NO.:
OF
SHEETS
DESIGNED BY:
DRAWN BY:
CHECKED BY:
SUBMITTED BY:
ISSUE DATE:
P R
O J E
C T
T
IT
L E
P R
O J E
C T
A D
D R
E S
S
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
S T
A T
U S
S H
E E
T T
IT
L E
C O
N T
R A
C T
N O
R E
V
IS
IO
N
S
D E
S C
R
IP
T
IO
N D
A T
E R
E V
1234567
F ile
P a th
X
F
Y \1
\0
.C
A D
B
IM
\0 .0
.B
IM
P lo t D a te
/2
/2
:0 :5
P
M
RSQ No.23-SQ-17LL
PROJ. No. PC3627
02/24/2025
BID AND CONSTRUCT SET
VOLUSIA COUNTY
BID AND CONSTRUCT SET
DELAND IT RESTROOM ENERGY CONSERV. MEASURES
119 WEST INDIANA AVENUE
DELAND, FL 32720
J O
B
O R
L .0
G-001
02/24/2025
JM
HD
HD
RP
R S
Q N o .2
-S
Q -1
L L
P R
O J N o P
C
C O
V E
R S
H E
E T
W
E S
T I N
D
IA
N A
A V
E N
U E
D E
L A
N D
F
L
D E
L A
N D
I T
R E
S T
R O
O M
E N
E R
G Y
C O
N S
E R
V
M E
A S
U R
E S
B
ID
A N
D C
O N
S T
R U
C T
S E
T
SITE MAP
VICINITY MAP
DRAWING LIST
NUMBER SHEET TITLE
I-604 SIGNAGE PLAN, SCHEDULE AND DETAILS
PLUMBING GENERAL
P-001 PLUMBING GENERAL NOTES, ABBREV., AND
LEGENDS
PLUMBING DEMOLITION
PD-101 GROUND FLOOR PLUMBING DEMOLITION PLAN
PD-102 GROUND FLOOR PLUMBING DEMOLITION PLAN
PLUMBING NEW WORK
PP-101 PLUMBING NEW WORK SUPPLY GROUND FLOOR
PLAN
PP-102 PLUMBING NEW WORK SUPPLY SECOND FLOOR
PLAN
PLUMBING FLOOR PLANS
PW-101 PLUMBING NEW WORK WASTE GROUND FLOOR
PLAN
PW-102 PLUMBING NEW WORK WASTE SECOND FLOOR
PLAN
P-501 PLUMBING DETAILS
PLUMBING SCHEDULES, DETAILS AND RISER DIAGRAMS
P-601 PLUMBING SCHEDULES
M-001 MECHANICAL GENERAL NOTES AND DESIGN
CRITERIA
M-002 MECHANICAL ABBREVIATIONS AND LEGENDS
MD-101 MECHANICAL DEMO GROUND FLOOR PLANS
MD-102 MECHANICAL DEMO SECOND FLOOR PLANS
MECHANICAL NEW WORK
M-101 MECHANICAL GROUND FLOOR PLANS
M-102 MECHANICAL SECOND FLOOR PLANS
ELECTRICAL
E-001 ELECTRICAAL GENERAL NOTES AND
ABBREVIATIONS
E-002 ELECTRICAL LEGEND
ED-101 1ST FLOOR DEMOLITION PLAN - POWER
ED-102 2ND FLOOR DEMOLITION PLAN - POWER
ED-201 1ST FLOOR DEMOLITION PLAN - LIGHTING
ED-202 2ND FLOOR DEMOLITION PLAN - LIGHTING
ELECTRICAL
E-101 1ST FLOOR NEW PLAN - POWER
E-102 2ND FLOOR NEW PLAN - POWER
E-201 1ST FLOOR NEW PLAN - LIGHTING
E-202 2ND FLOOR NEW PLAN - LIGHTING
ELECTRICAL
E-501 ELECTRICAL DETAILS
Grand total: 53
DRAWING LIST
NUMBER SHEET TITLE
GENERAL
G-001 COVER SHEET
ARCHITECTURAL - GENERAL
A-001 PROJECT INFORMATION - APPLICABLE CODE
INFO
A-002 ABBREVIATIONS
A-003 SYMBOLS AND LEGENDS
A-004 UL PIPE PENETRATIONS
A-005 ADA STANDARDS
A-006 LIFE SAFETY PLANS
ARCHITECTURAL - DEMOLITION
AD-101 1ST FLOOR DEMO PLAN
AD-102 2ND FLOOR DEMO PLAN
AD-121 1ST FLOOR REFLECTED CEILING DEMO PLANS
AD-122 2ND FLOOR REFLECTED CEILING DEMO PLANS
ARCHITECTURAL
A-101 1ST FLOOR NEW LAYOUT PLAN
A-102 2ND FLOOR NEW LAYOUT PLAN
A-121 1ST FLOOR REFLECTED CEILING NEW LAYOUT
PLAN
A-122 2ND FLOOR REFLECTED CEILING NEW LAYOUT
PLAN
A-350 TOILET PARTITIONS DETAILS
A-401 1ST FLR ENLARGED PLANS
A-402 2ND FLR ENLARGED PLANS
A-403 ENLARGED KITCHEN & MEDIA COUNTER
A-601 PARTITION TYPES
A-602 WALL FRAMING AND BLOCKING DETAILS
A-603 RESTROOM DETAILS
A-605 DOOR TYPES SCHEDULE AND WINDOW DETAILS
INTERIORS
I-601 INTERIOR FINISH PLAN
I-602 FIRST FLOOR RESTROOM ELEVATIONS
I-603 2ND FLOOR RESTROOM ELEVATIONS & DETAILS
27 (13.5) 1 1
53 (26.5) 2 2 12
1 1
3 3
2 32
1 11 12 321
1 1 2
1 2
4 1
1 11
1 10
1 1 1
LEVEL 02 - SECOND FLOOR
PLUMBING FIXTURES - FBC PLUMBING TABLE 403.1
OCCUPANCY
CLASSIFICATION/
DESCRIPTION
LEVEL 01 - FIRST FLOOR
BUSINESS - OFFICE BUILDING
MALE
PROPOSEDREQUIRED
WATER CLOSETS
FEMALE MALE
LAVATORIES
FEMALE 1 SER. SINK
OCCUPANT
LOAD
(DIVIDE
TOTAL BY
2. HALF
FOR EACH
SEX)
BUSINESS - OFFICE BUILDING
FOOTNOTES:
1. FPC 424.2 SUBSTITUTION FOR WATER CLOSETS IN EACH BATHROOM OR TOILET ROOM, URINALS SHALL NOT BE SUBSTITUTED FOR MORE THAN 67 PERCENT OF THE REQUIRED WATER CLOSETS IN
ASSEMBLY AND EDUCATIONAL OCCUPANCIES.
URINALS SHALL NOT BE SUBSTITUTED FOR MORE THAN 50 PERCENT OF THE REQUIRED WATER CLOSETS IN ALL OTHER OCCUPANCIES.
DRINKING FOUNTAINS
(Substitution per 410.4)
SERVICE SINK
(Business per Level)
1 per 25 for the first 50 and 1 per 50 for the remainder exceeding 50
1 per 40 for the first 80 and 1 per 80 for the remainder exceeding 80
1 per 100
EXISTING
WC URN WC URN WC URN
EXISTING
WC
PROPOSEDREQUIRED
WC WC
PROPOSEDREQUIREDEXISTING PROPOSEDREQUIREDEXISTING PROPOSEDREQUIREDEXISTING PROPOSEDREQUIREDEXISTINGPROPOSED
WC
UNISEX
URN
PROPOSED
UNISEX
PROJECT INFORMATION
VOLUSIA COUNTY
119 WEST INDIANA AVENUE
DELAND, FLORIDA, 32720
PHONE: 386-736-5935 FAX:386-736-5972
WWW.VOLUSIA.ORG OR PURCHASING@VOLUCIA.ORG
MR. OR MS. POINT OF CONTACT
OCCUPANCY LOAD
NO ADDITIONAL OCCUPANCY LOAD
FBC TABLE 1004.5
NFPA LIFE SAFETY CODE 101 TABLE 7.3.1.2
EXISTING RESTROOMS AND ONE JANITOR CLOSET ARE
WITHIN AN EXISTING BUSINESS OCCUPANCY
a. TWO PRIVATE RESTROOMS ON 1ST FLOOR
FUNCTIONAL OCCUPANCY OF SPACE: PRIVATE
IT OFFICE OCCUPANT LOAD FACTOR: 150 GROSS
CALCULATION 1ST FLOOR: BUSINESS AREAS
GROSS 7881SF / 150 OCC FACTOR = 52.54 ~ 53
b. TWO PRIVATE RESTROOMS ON 2ND FLOOR
FUNCTIONAL OCCUPANCY OF SPACE: PRIVATE
IT OFFICE OCCUPANT LOAD FACTOR: 150 GROSS
CALCULATION 2ND FLOOR: BUSINESS AREAS
GROSS 4000SF / 150 OCC FACTOR = 26.667 ~ 27
FLAME SPREAD & SMOKE-
DEVELOPMENT INDEX
1. ALL INSULATION MATERIALS TO HAVE A FLAME
SPREAD INDEX OF NOT MORE THAN 25 & A SMOKE-
DEVELOPED INDEX OF NOT MORE THAN 450-FBC'
SCOPE OF WORK
SCOPE IS LIMITED TO: NOT A SUBSTANTIAL
IMPROVEMENT
1. VOLUSIA COUNTY IT DEPARTMENT RESTROOMS,
INCLUDING THE INTERIOR RENOVATION OF TWO
RESTROOMS ON 1ST LEVEL AND TWO RESTROOMS
ON 2ND LEVEL, ONE JANITOR'S ROOMS ON 1ST
LEVEL AND ADDITION OF ONE JANITOR'S ROOM ON
2ND FLOOR, THE SCOPE ALSO INCLUDES
REPLACEMENT OF WALL AND BASE CABINETS IN
KITCHEN AND CONFERENCE ROOM AS FOLLOWS:
2. THE WORK INCLUDES:
a. SELECTIVE INTERIOR DEMOLITION OF EXISTING
RESTROOMS/JANITORS.
b. NEW WET PARTITION WALLS & CHASES
A. NEW TOILET COMPARTMENTS
c. NEW FINISHES (FLOOR, WALL.CEILING)
d. NEW TOILET ACCESSORIES
e. NEW PLUMBING FIXTURES
3. STRUCTURAL, MECHANICAL, ELECTRICAL, AND
PLUMBING WORK AS REQUIRED.
APPLICABLE CODES:
CODE YEAR AUTHORITY HAVING
JURISDICTION
BUILDING FLORIDA BUILDING CODE 2023 VOLUSIA COUNTY
(EXISTING BUILDING)
ACCESSIBILITY FLORIDA BUILDING CODE 2023 VOLUSIA COUNTY
(ACCESSIBILITY)
LIFE SAFETY NFPA 101- LIFE SAFETY CODE 2023 VOLUSIA COUNTY
W/ FLORIDA AMENDMENTS FIRE DEPARTMENT
FIRE FFPC - FLORIDA FIRE 8th EDITION VOLUSIA COUNTY
PREVENTION PREVENTION CODE FIRE DEPARTMENT
NFPA-1 UNIFORM FIRE 8th EDITION VOLUSIA COUNTY
CODE W/ FLORIDA FIRE DEPARTMENT
AMENDMENTS
ENERGY FLORIDA BUILDING CODE 2023 VOLUSIA COUNTY
(ENERGY)
ELECTRICAL FLORIDA BUILDING CODE 2023 VOLUSIA COUNTY
(ELECTRICAL)
MECHANICAL FLORIDA BUILDING CODE 2023 VOLUSIA COUNTY
(MECHANICAL)
PLUMBING FLORIDA BUILDING CODE 2023 VOLUSIA COUNTY
(PLUMBING)
GAS FLORIDA BUILDING CODE 2023 VOLUSIA COUNTY
(GAS)
NOTES:
1. FBC SECTION 110.8.4.4: "TO THE BEST OF THE ARCHITECT/ENGINEER'S
KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE
APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRE SAFETY
STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE
WITH THIS SECTION AND CHAPTER 633, FLORIDA STATUTES."
2. COMPLY WITH AMERICAN WITH DISABILITIES ACT AND UNIFORM FEDERAL
ACCESSIBILITY STANDARDS (UFAS), WHERE APPLICABLE AND TO THE BEST
OF THE ARCHITECT/ENGINEER'S KNOWLEDGE, THIS PROJECT HAS BEEN
DESIGNED IN ACCORDANCE WITH THE AMERICANS WITH DISABILITIES ACT,
AND FLORIDA ACCESSIBILITY CODE 2023.
3. ANY CODES & STANDARDS REFERENCED IN THE APPLICABLE CODES CITED
HEREIN, ARE HEREBY INCORPORATED INTO THIS DOCUMENT AS IF THEY WERE
SPECIFICALLY CITED WITHIN THESE DOCUMENTS.
LEVEL OF ALTERATION:
ALTERATION
LEVEL 2 FBC-EXISTING BUILDING (2023)
Section 504.1 Scope.
Level 2 alterations include the reconfiguration of space, the addition or elimination of any door or window, the reconfiguration or extension of any system, or the installation of any additional equipment.
CLASSIFICATION OF REHABILITATION WORK CATEGORY
RENOVATION NFPA 101. LIFE SAFETY CODE W/ FLORIDA AMENDMENTS
AND (2015) MODIFICATION
43.2.2.1.2 Renovation. The replacement in kind, strengthening, or upgrading of building elements, materials, equipment, or fixtures, that does not result in a reconfiguration of the building spaces within.
43.2.2.1.3 Modification. The reconfiguration of any space; the addition, relocation, or elimination of any door or window; the addition or elimination of load-bearing elements;
there configuratlon or extension of any system; or the installation of any additional equipment.
GENERAL CONDITIONS
THIS SET OF DRAWINGS SHOULD NOT BE SCALED, USE DIMENSIONS AND INFORMATION
SHOWN.
PRIOR TO PROCEEDING WITH ANY WORK AND FABRICATION, THE CONTRACTOR SHALL:
VERIFY AND COORDINATE WITH ANY ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS
AND ELEVATIONS SHOWN OR NOT SHOWN ON THE STRUCTURAL DRAWINGS.
ANY DIMENSIONAL DISCREPANCY FOUND ON THE STRUCTURAL DRAWINGS SHALL BE
CONTROLLED BY THE DIMENSIONS INDICATED ON THE ARCHITECTURAL DRAWINGS.
CONTRACTOR SHALL FURTHER VERIFY AND CONFIRM WITH THE ARCHITECT AND THE
STRUCTURAL ENGINEER FOR RESOLUTION OF SUCH DISCREPANCY.
VERIFY ALL EXISTING CONDITIONS AT THE JOB SITE, PROTECT AND MAINTAIN ALL
EXISTING STRUCTURES, UTILITIES, FACILITIES AND THEIR CONTENTS.
REFER TO ARCHITECTURAL AND OTHER DRAWINGS FOR ANY DEMOLITION AND
ADJUSTMENT / REMOVAL OF ANY UNDERGROUND / OVERHEAD UTILITIES.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATE BRACING OF ALL
STRUCTURAL MEMBERS, WALLS AND NON-STRUCTURAL ITEMS DURING
CONSTRUCTION.
THESE STRUCTURAL NOTES ARE LIMITED IN SCOPE TO PROVIDE ANCHORAGE &
SUPPORT TO INTERIOR PARTITIONS AT LOCATION OF ELEMENTS SUCH AS STRUCTURAL
CRITERIA FOR CEILING, AND STRUCTURAL BRACING FOR WALL.
REFER TO AND COORDINATE WITH THE ARCHITECTURAL, MECHANICAL, ELECTRICAL
AND PLUMBING DRAWINGS FOR UTILITIES, OPENINGS, SLEEVES, ETC. NOT SHOWN ON
THE STRUCTURAL NOTES.
THE GENERAL CONTRACTOR SHALL AT ALL TIMES MAINTAIN A CURRENT APPROVED
SET OF DRAWINGS AT THE JOBSITE.
THE STRUCTURAL COMPONENTS FOR THIS PROJECT HAVE BEEN DESIGNED IN
COMPLIANCE WITH THE FLORIDA BUILDING CODE (FBC) 2023.
THE FOLLOWING LOADS HAVE BEEN USED FOR THE STRUCTURAL DESIGN OF THE
SUPPORT ELEMENT & CEILING:
SUPERIMPOSED GRAVITY LOADS:
BABY CHANGING STATION & BENCH:
UNIFORM LOAD
DEAD LOAD = 40 PSF
LIVE LOAD = 40 PSF
CONCENTRATED LOAD = 300 LBS
CEILING LOADS:
UNIFORM LOAD
DEAD LOAD = 25 PSF
LIVE LOAD = 20 PSF
PARTITION PRESSURE: = 5 PSF
WIND LOADS:
IN ACCORDANCE WITH ASCE 7-16 WITH 3-SECOND SUSTAINED WIND GUSTS.
BUILDING CATEGORY III; WIND VELOCITY = 180 MPH
EXPOSURE = D
ENCLOSURE CATEGORY: ENCLOSED, ROOFTOP EQUIPMENT CHAPTER 29 ASCE 7-16
SHOP DRAWINGS
ALL REINF. STEEL, STRUCTURAL STEEL, SHOP DRAWINGS, ALONG WITH THEIR RESPECTIVE
CALCULATIONS (WHEN APPLICABLE), SHALL BE SIGNED AND SEALED BY A PROFESSIONAL
ENGINEER REGISTERED IN THE STATE OF FLORIDA, AND SHALL BE SUBMITTED TO THE
ARCHITECT / ENGINEER FOR REVIEW PRIOR TO BE SUBMITTED TO THE BUILDING DEPARTMENT
AND PRIOR TO ERECTION AND / OR FABRICATION.
SHOP DRAWINGS WILL BE REVIEWED FOR COMPLIANCE WITH THE CONCEPTUAL DESIGN ONLY.
QUANTITY, DIMENSIONS, ELEVATIONS ARE RESPONSIBILITY OF THE CONTRACTOR.
CONCRETE
ALL SHALL BE A MIX DESIGNED IN ACCORDANCE WITH A.C.I. 301 (LATEST EDITION) TO ACHIEVE A
28-DAY COMPRESSIVE STRENGTH OF 3,500 P.S.I. AND A MAXIMUM WATER-CEMENT RATIO OF
0.40 AND A SLUMP OF 4"+1".
TRANSPORTATION, PLACING, AND CURING OF CONCRETE SHALL COMPLY WITH A.C.I. 318
(LATEST EDITION).
ALL CONCRETE STRUCTURAL COMPONENTS SHALL HAVE CONCRETE STRENGTH TESTED IN
ACCORDANCE WITH A.S.T.M. STANDARDS, FLORIDA BUILDING CODE 2023 AND ACI 318 (LATEST
EDITION)
BRACING
THE FRAME SHALL BE BUILT TRUE AND PLUMB AND TEMPORARY BRACING SHALL BE INTRODUCED
WHEREVER NECESSARY TO TAKE CARE OF ALL LOADS TO WHICH THE STRUCTURE MAY BE
SUBJECTED, INCLUDING EQUIPMENT AND OPERATION OF SAME.
SUCH BRACING SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND SHALL BE
LEFT IN PLACE AS LONG AS REQUIRED FOR SAFETY. CONTRACTOR SHALL PROVIDE BRACING SHOP
DRAWINGS SIGNED AND SEALED BY PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF
FLORIDA
R A
Y M
O N
D
G
E
C
A
F
D
B
H
1 3 5 7 92 4 6 8 10 11
T H
E
IN
F O
R M
A T
IO
N
C O
N T
A
IN
T H
IS
D
R A
W
IN
G
IS
T
E
LL
E C
T U
A L
A N
D P
H Y
S
IC
A L
C O
P Y
R
IG
H T
P R
O P
E R
T Y
Y M
O N
D E
N G
IN
E
E R
IN
G
G E
O R
G
IA
IN
C
A
N D
M A
Y N
D U
P
LI
C A
T E
D
IN
P A
R T
O
O
LE
IN
A
N Y
M A
N N
LU
D
IN
G
IM
A
G
IN
G
E
LE
C T
R O
N
IC
S C
A N
N
IN
G
A P
H
IC
R E
P R
O D
U C
T
IO
N
N D
T R
A N
S F
E R
E , W
IT
H
O
E E
X P
R E
S S
W R
IT
T
R M
IS
S
IO
N
O F
T H
E A
U T
H O
R
R A
Y M
O N
D E
N G
IN
E
E R
IN
G
G E
O R
G
IA
IN
C
A
LL
R
IG
H
S E
R V
E D
, Y E
A R
A S
D A
T E
D
R A
Y M
O N
D P
R O
J E
C T
N O
C
O P
Y R
IG
H
T
G
R E
E N
S T
R E
E T
S E
S
U
IT
E A
C O
N Y
E R
S G
E O
R G
IA
-6
-2
R a ym o n d
E n g in ee ri n g
G eo rg ia
, I N
C
SHEET NO.:
OF
SHEETS
DESIGNED BY:
DRAWN BY:
CHECKED BY:
SUBMITTED BY:
ISSUE DATE:
P R
O J E
C T
T
IT
L E
P R
O J E
C T
A D
D R
E S
S
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
S T
A T
U S
S H
E E
T T
IT
L E
C O
N T
R A
C T
N O
R E
V
IS
IO
N
S
D E
S C
R
IP
T
IO
N D
A T
E R
E V
1234567
F ile
P a th
X
F
Y \1
\0
.C
A D
B
IM
\0 .0
.B
IM
P lo t D a te
/2
/2
:0 :3
P
M
J O
B
O R
L .0
A-001
02/24/2025
Approver
Designer
Author
Checker
R S
Q N o .2
-S
Q -1
L L
P R
O J N o P
C
B
ID
A N
D C
O N
S T
R U
C T
S E
T
P R
O J E
C T
I N
F O
R M
A T
IO
N
A
P P
L
IC
A B
L E
C O
D E
I N
F O
W
E S
T I N
D
IA
N A
A V
E N
U E
D E
L A
N D
F
L
D E
L A
N D
I T
R E
S T
R O
O M
E N
E R
G Y
C O
N S
E R
V
M E
A S
U R
E S
B
ID
A N
D C
O N
S T
R U
C T
S
A/C AIR CONDITION
A/E ARCHITECT/ENGINEER
ABAN ABANDON
ABRSV ABRASIVE
ACC ACCESSIBLE
ACST INSUL ACOUSTICAL INSULATION
ACST PNL ACOUSTICAL PANEL
ACP AUTOMATIC CONTROL PANEL
ACST ACOUSTIC
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADJ ADJACENT or ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AHJ AUTHORITY HAVING JURISDICTION
ALT ALTERNATE
ALUM ALUMINUM
APPROX APPROXIMATE
ARCH ARCHITECT
ASB ASBESTOS
ASC ABOVE SUSPENDED CEILING
ASD AUTOMATIC SPRINKLER DRAIN
ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTION
ASSN ASSOCIATION
AVG AVERAGE
BAT BATTEN
BD BOARD
BD FT BOARD FEET (FOOT)
BDRY BOUNDARY
BF BOTH FACES
BFF BELOW FINISH FLOOR
BLDG BUILDING
BLKHD BULKHEAD
BLKT BLANKET
BN BULLNOSE
B/STL BOTTOM OF STEEL
BOT BOTTOM
BSMT BASEMENT
BTWN BETWEEN
BYP BY PASS
CAB CABINET
CANTIL CANTILEVER
CB CORNER BEAD
CCTV CLOSED CIRCUIT TELEVISION
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED
CF/OI CONTRACTOR FURNISHED/OWNER INSTALLED
CFE CONTRACTOR FURNISHED EQUIPMENT
CFMF COLD-FORMED METAL FRAMING
CG CORNER GUARD
CH BD CHALKBOARD
CIP CAST-IN-PLACE
CJ CONSTRUCTION JOINT\ CONTROL JOINT
C/L CENTER LINE
CLDG CLADDING
CLG CEILING
CLR CLEAR
CLT CLEAT
CMPST COMPOSITE
CMU CONCRETE MASONRY UNIT
CNCL CONCEALED
CO CLEANOUT
COL COLUMN
CONC CONCRETE
COND CONDITION
CONF CONFERENCE
COORD COORDINATE
CORR CORRIDOR
CP CONTROL PANEL
CSB CONCRETE SPLASH BLOCK
COTR CONTRACTING OFFICER'S TECHNICAL REPRESENTATIVE
DBL DOUBLE
DEMO DEMOLITION/DEMOLISH
DEPT DEPARTMENT
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DISP DISPENSER
DIST DISTANCE
ABBREVATION NOTES:
1. ABBREVIATIONS LISTED BELOW APPLY TO THE ARCHITECTURAL DRAWINGS ONLY, REFER TO CONSTRUCTION DOCUMENTS FOR ABBREVIATIONS USED.
2. REFER TO FINISH SCHEDULE FOR FINISH MATERIAL ABBREVAITIONS NOT SHOWN.
DMPF DAMPPROOFING
DPTN DEMOUNTABLE PARTITION
DS DOWNSPOUT
DSP DRY STANDPIPE
DSPL DISPOSAL
DW DISHWASHER
EA EACH
EC EDGE OF CURB
EFS EXTERIOR FINISH SYSTEM
EG EDGE GRAIN
EGB EXTERIOR GYPSUM WALL BOARD
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EFG ENTRANCE FLOOR GRILLE
EJ EXPANSION JOINT
EL ELEVATION
ELAST ELASTOMERIC
ELEC ELECTRIC
ELEM ELEMENTARY
ELEV ELEVATOR
EMER EMERGENCY
EMER SHR EMERGENCY SHOWER
ENAM ENAMEL
ENCL ENCLOSURE
ENTR ENTRANCE
EOS EDGE OF SLAB
EP EXPOXY PAINT
EPS EXPANDED POLYSTYRENE BOARD (INSULATION)
EPX EPOXY
EQ EQUAL
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ERD EXISTING ROOF DRAIN
ESCAL ESCALATOR
EWH ELECTRIC WATER HEATER
EWS EYE WASH STATION
EXIST EXISTING
EXP EXPOSED
EXT EXTERIOR
FA FIRE ALARM
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDCC FIRE DEPARTMENT CONNECTION CABINET
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF&E FURNITURE, FIXTURE, AND EQUIPMENT
FH FIRE HOSE/ FIRE HYDRANT
FIN FINISH
FIN GR FINISH GRADE
FIXT FIXTURE
FL FLOORLINE
FO FINISHED OPENING
FOC FACE OF CONCRETE/ FACE OF CURB
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUD
FOW FACE OF WALL
FRG FIBER REINFORCED GYPSUM
FURN FURNITURE
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GDR GUARD RAIL
GFRC GLASS-FIBER-REINFORCED CONCRETE
GFRG GLASS-FIBER-REINFORCED GYPSUM
GFRP GLASS-FIBER-REINFORCED PLASTER
GFRP GLASS-FIBER-REINFORCED PLASTIC
GL GLASS/GLAZING
GMP GUARANTEED MAXIMUM PRICE
GR GROUT
GRAN GRANITE
GT GREASE TRAP
GYP BD GYPSUM WALL BOARD
HB HOSE BIBB
HC HOLLOW CORE
HCP HANDICAPPED
HCWD HOLLOW CORE WOOD DOOR
HDW HARDWARE
HDWD HARDWOOD
HM HOLLOW METAL
ID INSIDE DIAMETER/ INSIDE DIMENSION
INSUL INSULATION
INSUL PNL INSULATED METAL PANEL
JAN JANITOR
JT JOINT
KD KNOCKED DOWN
KPL KICKPLATE
LAM LAMINATE
LAM GL LAMINATED GLASS
LAV LAVATORY
LCD LINEAR CEILING DIFFUSER
LCMU LIGHTWEIGHT CONCRETE MASONRY UNIT
LDG LANDING
LDR LEADER
LF LINEAR FEET (FOOT)
LOS LINE OF SIGHT
LVDR LOUVER DOOR
LVR LOUVER
LWC LIGHTWEIGHT CONCRETE
MAINT MAINTENANCE
MAX MAXIMUM
MC METAL-CLAD
MCB METAL CORNER BEAD
MED MEDICAL
MEL MELAMINE
MEZZ MEZZANINE
MF MILL FINISH
MID MIDDLE
MIN MINIMUM
MIRR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING (MOULDING)
MLWK MILLWORK
MOD BIT MODIFIED BITUMEN
MOPR MOP RACK
MR MOISTURE RESISTANT
MTL METAL
MW MICROWAVE
MWP MEMBRANE WATERPROOFING
N/A NOT APPLICABLE
NCOMBL NONCOMBUSTIBLE
NIC NOT IN CONTRACT
NLB NONLOADBEARING
NO NUMBER
NOM NOMINAL
NTP NOTICE TO PROCEED
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OF OVERFLOW
OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED
OFD OVERFLOW DRAIN
OF/OI OWNER FURNISHED/OWNER INSTALLED
OFS OUTSIDE FACE OF STUDS
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
PAT PATTERN
PBD PARTICLEBOARD
PERF PERFORATED
PERM PERMANENT
PERP PERPENDICULAR
PGBD PEGBOARD
PJ PANEL JOINT
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PLYWD PLYWOOD
POL POLISHED
PORC PORCELAIN
PREFAB PREFABRICATE
PREFIN PREFINISH
PT PRESSURE TREATED
PTD PAINT
R RADIUS
RADN RADIATION
RB RESILIENT BASE
RBR RUBBER
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REBAR REINFORCING STEEL BARS
REF REFERENCE
REINF REINFORCE
REQD REQUIRED
RESIL RESILIENT
RESP RESIN PANEL
RFG ROOFING
RH ROOF HATCH
RLG RAILING
RM ROOM
RO ROUGH OPENING
RTF RUBBER TILE FLOOR
RTU ROOF TOP UNIT
RV ROOF VENT
RVL REVEAL
SB SPLASH BLOCK
SBSTR SUBSTRATE
SCHED SCHEDULE
SCRN SCREEN
SD SMOKE DETECTOR
SHR SHOWER
SHRD SHOWER DRAIN
SIM SIMILAR
SP STANDPIPE
SPEC SPECIFICATION(S)
SPKLR SPRINKLER
SPKR SPEAKER
SQ FT SQUARE FOOT
SS SOLID SURFACE
SST STAINLESS STEEL
ST STAIR(S)
STC SOUND TRANSMISSION CLASS
STOR STORAGE
STN STAIN
SUSP CLG SUSPENDED CEILING
SYMM SYMMETRICAL
TBD TO BE DETERMINED
T&G TONGUE AND GROOVE
TD TRENCH DRAIN
TEMP TEMPORARY
TFA TO FLOOR ABOVE
TFB TO FLOOR BELOW
THRU THROUGH
TLT TOILET
T/ TOP OF ___
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOS TOP OF SLAB\ TOP OF STEEL
TOW TOP OF WALL
TP TOILET PARTITION
TRS (or TR) TRANSITION STRIP
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VNR VENEER
W/ WITH
W/O WITHOUT
WB WOOD BASE
WC WATER CLOSET
WD WOOD
WF WASH FOUNTAIN
WH WATER HEATER
WHSE WAREHOUSE
WP WALL PROTECTION
WSCT WAINSCOT
WWF WELDED WIRE FABRIC
WWM WELDED WIRE MESH
XPS EXTRUDED POLYSTYRENE BOARD (INSULATION)
R A
Y M
O N
D
G
E
C
A
F
D
B
H
1 3 5 7 92 4 6 8 10 11
T H
E
IN
F O
R M
A T
IO
N
C O
N T
A
IN
T H
IS
D
R A
W
IN
G
IS
T
E
LL
E C
T U
A L
A N
D P
H Y
S
IC
A L
C O
P Y
R
IG
H T
P R
O P
E R
T Y
Y M
O N
D E
N G
IN
E
E R
IN
G
G E
O R
G
IA
IN
C
A
N D
M A
Y N
D U
P
LI
C A
T E
D
IN
P A
R T
O
O
LE
IN
A
N Y
M A
N N
LU
D
IN
G
IM
A
G
IN
G
E
LE
C T
R O
N
IC
S C
A N
N
IN
G
A P
H
IC
R E
P R
O D
U C
T
IO
N
N D
T R
A N
S F
E R
E , W
IT
H
O
E E
X P
R E
S S
W R
IT
T
R M
IS
S
IO
N
O F
T H
E A
U T
H O
R
R A
Y M
O N
D E
N G
IN
E
E R
IN
G
G E
O R
G
IA
IN
C
A
LL
R
IG
H
S E
R V
E D
, Y E
A R
A S
D A
T E
D
R A
Y M
O N
D P
R O
J E
C T
N O
C
O P
Y R
IG
H
T
G
R E
E N
S T
R E
E T
S E
S
U
IT
E A
C O
N Y
E R
S G
E O
R G
IA
-6
-2
R a ym o n d
E n g in ee ri n g
G eo rg ia
, I N
C
SHEET NO.:
OF
SHEETS
DESIGNED BY:
DRAWN BY:
CHECKED BY:
SUBMITTED BY:
ISSUE DATE:
P R
O J E
C T
T
IT
L E
P R
O J E
C T
A D
D R
E S
S
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
S T
A T
U S
S H
E E
T T
IT
L E
C O
N T
R A
C T
N O
R E
V
IS
IO
N
S
D E
S C
R
IP
T
IO
N D
A T
E R
E V
1234567
F ile
P a th
X
F
Y \1
\0
.C
A D
B
IM
\0 .0
.B
IM
P lo t D a te
/2
/2
:0 :3
P
M
J O
B
O R
L .0
A-002
02/24/2025
Approver
Designer
Author
Checker
R S
Q N o .2
-S
Q -1
L L
P R
O J N o P
C
B
ID
A N
D C
O N
S T
R U
C T
S E
T
A B
B R
E V
IA
T
IO
N
S
W
E S
T I N
D
IA
N A
A V
E N
U E
D E
L A
N D
F
L
D E
L A
N D
I T
R E
S T
R O
O M
E N
E R
G Y
C O
N S
E R
V
M E
A S
U R
E S
B
ID
A N
D C
O N
S T
R U
C T
S E
ABBREVIATIONS LIST
BATT
INSULATION
CONCRETE
POROUS FILL
(STONE OR
GRAVEL)
STEEL
BRICK
CONCRETE
MASONRY
UNIT (CMU)
RIGID
INSULATION
WOOD -
FINISHED
COMPACTED
EARTH
PLYWOOD
SAND, PLASTER,
CEMENT,
GROUT, GYPSUM
WALL BOARD
WOOD - ROUGH
LINE TYPES
BEYOND
CENTERLINE
DEMOLISHED
HIDDEN
OVERHEAD
ANNOTATIONS
'X' 'X'
CL
XX.X
CENTERLINE
DIMENSION
FACE
DIMENSION
COLUMN GRID TAG -
NEW
ALIGN FACE OF
SURFACES
ALIGN
SPOT ELEVATION
0'-0"
LEVEL / ELEVATION
HEIGHT
REVISION TAG AND
CLOUD
NORTH (PROJECT)
PROJECT NORTH
TRUE NORTH
FURNITURE TAGF1
EQUIPMENT TAGE123456
SIGNAGE TAGS99
CEILING TAG
AFF
1t
10'-0" CEILING TYPE (WHEN INDICATED)
CEILING HEIGHT
ROOM TAG(S):
ROOM TAG WITH AREA
(NO ROOM #)
ROOM NAME
1500 SF
DEPARTMENT OR PHASE
(IF SHOWN)ROOM NAME
00999
DEPT/ PHASE
ROOM NAME
FLOOR # = 1 OR 2 DIGITS
ROOM # = 2 OR 3 DIGITS
AREA (IF SHOWN)
ROOM NAME
00999
150 SF
DOOR TAG:
DOOR RATING (IF SHOWN)
FLOOR # = 1 OR 2 DIGITS
ROOM # = 2 OR 3 DIGITS
122A
DOOR SEQUENCE (ALPHABETIC)
VIEW REFERENCE
PHOTO REFERENCE TAG
1/ A
A1
VIEW NAME
1/8" = 1'-0"
PLAN VIEW TITLE REFERENCE
LOCATION ON THE SHEET
VIEW SCALE
SIM
A103
PLAN / DETAIL CALLOUT
REFERENCED
SHEET
A610
SIM
BUILDING SECTION CALLOUT
REFERENCED
SHEET
A5
A610
SIM
WALL SECTION CALLOUT
REFERENCED
SHEET
A601
SIM
DETAIL SECTION CALLOUT
REFERENCED
SHEET
A510
1 Ref
1 Ref 1 Ref
1 Ref
EXTERIOR ELEVATION CALLOUT
A1011 INTERIOR ELEVATION CALLOUT
A1 Ref
A1 Ref A1 Ref
A1 Ref
AREA ONLY1500 SF
XX.X BUILDING LINE GRID
TAG - NEW
WINDOW / CURTAIN WALL TAGA
LOUVER TAGL1
WALL TAG
KEYNOTE
ACCESSORY TAGTA-1
?A08
TRUE NORTHPLAN NORTH
A1
VIEW NAME
1/8" = 1'-0"
DETAIL VIEW TITLE REFERENCE
LOCATION ON THE SHEET
VIEW SCALE
WALL TYPE NUMBER
STUD SCHEDULE
1 = 4" ABOVE CEILING
2 = FLOOR TO UNDERSIDE OF TRUSS
3 = FULL HEIGHT OR AS INDICATED ON PLAN / SECTION
FIRE RESISTANCE DESIGNATION
4 = ONE HOUR
5 = TWO HOUR
INSULATION DESIGNATION
THERMAL INSULATION
SOUND INSULATION
ACOUSTIC WALL TREATMENT
A #
DRAWING NUMBERS SHALL BE FORMATTED AS SHOWN
BELOW. ESTABLISH IF LEVEL 1 AND/OR LEVEL 2 DISCIPLINE
DESIGNATORS ARE REQUIRED AND FOLLOW THE
DESIGNATORS AS DESCRIBED BELOW.
2 DIGIT DISCIPLINE
DESIGNATOR (IF ONLY
ONE LETTER IS USED, THE
SECOND LETTER IS
REPLACED WITH A DASH "-"
AS A PLACEHOLDER)**
1 DIGIT AREA
DESIGNATOR
(AREA DESIGNATOR
ONLY USED WHEN
PLANS ARE
SUBDIVIDED INTO
AREAS.)
1 DIGIT SHEET TYPE
DESIGNATOR
0 - GENERAL
1 - PLANS
2 - ELEVATIONS
3 - SECTIONS
4 - ENLARGED PLANS
5 - DETAILS
6 - SCHEDULES AND
DIAGRAMS
7 - VARIES
8 - VARIES
9 - 3D VIEWS (ISO,
PERSPECTIVES)
2 DIGIT SEQUENTIAL
# (01-99) (FIRST DIGIT
INDICATES PLAN
TYPE. SECOND DIGIT
INDICATES FLOOR)
A-001A
SHEET NUMBERING
1. THE DRAWINGS INDICATE THE GENERAL EXTENT OF WORK. THE DRAWINGS
ARE NOT INTENDED TO INDICATE OR DESCRIBE ALL WORK REQUIRED FOR
THE FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE
CONTRACT DOCUMENTS.
2. THE ENUMERATION OF PARTICULAR ITEMS OF WORK IN ONE PORTION OF THE
CONTRACT DOCUMENTS SHALL NOT BE CONSTRUED TO EXCLUDE OTHER
ITEMS NECESSARY OR IMPLIED THEREFROM.
3. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL PARTS
OF THE WORK SO THAT NO WORK SHALL BE LEFT IN AN UNFINISHED OR
INCOMPLETE CONDITION.
4. ALL WORK SHALL CONFORM TO APPLICABLE INDUSTRY AND
MANUFACTURER'S PUBLISHED STANDARDS FOR QUALITY OF MATERIALS AND
WORKMANSHIP, AS WELL AS, ALL REQUIREMENTS IN THESE DRAWINGS AND
SPECIFICATIONS. ANY CONFLICTING REQUIREMENTS OF THE SOURCES
LISTED ABOVE SHALL BE BROUGHT TO THE CONTRACTING OFFICER'S
ATTENTION PRIOR TO PROCEEDING WITH THE WORK.
5. THE CONTRACTOR SHALL PROTECT ANY EXISTING, IN-PLACE, AND NEW
WORK.
6. ALL WORK NOTED "N.I.C." IS NOT MEANT TO BE PART OF THE CONSTRUCTION
SCOPE OF WORK AGREEMENT.
7. THE CONTRACTOR SHALL PAY FOR AND COORDINATE THE REMOVAL AND
LEGAL DISPOSAL OF MATERIALS AND RUBBISH.
8. ONCE ON SITE, THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SHALL
VERIFY ALL NEW AND EXISTING CONDITIONS SHOWN ON THESE DRAWINGS.
THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER IN WRITING OF
ANY DIFFERING CONDITIONS BEFORE COMMENCEMENT OF WORK.
9. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN, LARGE SCALE DETAILS
GOVERN OVER SMALL-SCALE DETAILS. THE CONTRACTOR SHALL NOTIFY THE
CONTRACTING OFFICER IN WRITING OF ANY DIFFERING CONDITIONS BEFORE
COMMENCEMENT OF WORK.
10. UNLESS NOTED OTHERWISE, ALL GYPSUM BOARD SURFACES ARE TO
RECEIVE ONE PRIMER COAT AND TWO COATS OF PAINT.
11. DIMENSIONS NOTED AS 'HOLD' SHALL NOT VARY BY MORE THAN 1/8" FROM
SIDE TO SIDE OR FROM FRONT TO BACK, FINISHED SURFACE TO FINISHED
SURFACE.
12. NFPA 241, STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION,
AND DEMOLITION OPERATIONS SHALL BE APPLIED.
13. IF BUILDING IS OCCUPIED DURING CONSTRUCTION, CONTRACTOR SHALL
AVOID PASSAGE THROUGH OCCUPIED AREAS.
14. DIMENSIONS SHOWN ARE TO FACE OF WALL OR CMU (U.N.O.).
15. PROVIDE EXPANSION AND CONTROL JOINTS IN ALL WORK AS PER
PRODUCT MANUFACTURER'S STANDARDS.
16. THE CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH ALL
APPLICABLE CODES, ORDINANCES AND REGULATORY AGENCIES AND SHALL
OBTAIN NECESSARY BUILDING AND FIRE PERMITS FROM ALL AUTHORITIES
HAVING JURISDICTION.
17. ALL INTERIOR FINISH MATERIALS SHALL COMPLY WITH THE REQUIREMENTS
OF ALL APPLICABLE CODES, ORDINANCES AND REGULATORY AGENCIES.
18. ALL DISSIMILAR METALS SHALL BE ISOLATED FROM EACH OTHER TO AVOID
GALVANIC CORROSION.
19. NOTES APPEAR ON VARIOUS SHEETS FOR DIFFERENT SYSTEMS AND
MATERIALS. SHEETS ARE TO BE REVIEWED AND NOTES ON INDIVIDUAL
SHEETS SHALL BE APPLIED TO RELATED DRAWINGS AND DETAILS.
20. A FINISH INDICATION ON A WALL SHALL MEAN THE ENTIRE LENGTH AND
HEIGHT OF WALL IS TO BE FINISHED OR FIRE RATED AS INDICATED.
21. WHEN NON-DIMENSIONED PARTITIONS APPEAR IN CONJUNCTION WITH DOOR
OPENINGS, THE DOOR WIDTH AND THE DOOR FRAME DETAILS DETERMINE
THE LOCATION OF ADJACENT WALLS AND FRAMES.
22. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE DETAILED.
WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE
DETERMINED, CONSULT THE CONTRACTING OFFICER BEFORE PROCEEDING
WITH THE WORK.
23. THE CONTRACTOR SHALL COORDINATE ALL MECHANICAL AND ELECTRICAL
FLOOR AND WALL SLEEVES INCLUDING CONDUITS WITH ALL MECHANICAL,
ELECTRICAL, PLUMBING, FIRE PROTECTION, STRUCTURAL AND
ARCHITECTURAL DRAWINGS.
24. PROVIDE ACCESS PANELS AS REQUIRED BY APPLICABLE CODES AND AS
REQUIRED FOR MECHANICAL EQUIPMENT AND PLUMBING WORK. ALL ACCESS
PANELS SHALL BE CONCEALED AND LOCATIONS SHALL BE REVIEWED WITH
THE CONTRACTING OFFICER PRIOR TO PROCEEDING.
25. ALL PIPE DUCTS AND BUS DUCTS THAT PENETRATE FLOOR SLABS OR
WALL PARTITIONS SHALL BE INSTALLED IN A MANNER THAT WILL
PRESERVE THE MOISTURE RESISTIVENESS, FIRE RATING, AND STRUCTURAL
INTEGRITY OF THE BUILDING.
26. DO NOT CUT INTO, REMOVE OR ALTER ANY STRUCTURAL MEMBER OR
PORTION OF THE FLOOR SYSTEM UNLESS IT IS SPECIFICALLY NOTED OR
SHOWN ON THE STRUCTURAL DRAWINGS.
27. INTERIOR PARTITION MOVEMENT CONTROL:
A. VERTICAL CONTROL JOINTS FOR ANY WALL LENGTH ARE TO OCCUR AT
NOT MORE THAN 30'-0" O.C. IN THE HORIZONTAL DIRECTION, UNLESS
NOTED OTHERWISE.
B. PROVISIONS SHALL BE MADE IN THE DESIGN, FABRICATION, AND
INSTALLATION OF INTERIOR PARTITIONS FOR TYPICAL FLOOR
DEFLECTIONS OF THE STRUCTURE UNDER SUPERIMPOSED LOADS AS
FOLLOWS:
1. TYPICAL ROOF/FLOOR MEMBERS: SPAN/360 BUT NOT LESS THAN 1/2”.
28. THE CONTRACTOR SHALL PLAN THE WORK TO PROVIDE ADEQUATE
PROTECTION FOR PERSONS AND PROPERTY AT ALL TIMES, AND EXECUTE
THE WORK IN SUCH A MANNER TO AVOID ANY HAZARD TO PERSONS AND
PROPERTY AS NECESSARY.
29. THE CONTRACTOR SHALL COORDINATE THE PHASING OF THE WORK TO BE
PERFORMED IN OR ABOUT EXISTING FACILITIES, IF APPLICABLE, WITH THE
CONTRACTING OFFICER PRIOR TO START OF SUCH WORK.
30. CONTRACTOR SHALL PROTECT ALL EXISTING FINISHES INSIDE THE BUILDING
DURING CONSTRUCTION ACTIVITIES. ANY FLOORING, CEILING, WALLS, OR
OTHER FINISHES DAMAGED SHALL BE REPAIRED TO MATCH EXISTING
CONDITIONS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DOCUMENT ALL
EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION AND PRESENT TO
COR.
R A
Y M
O N
D
G
E
C
A
F
D
B
H
1 3 5 7 92 4 6 8 10 11
T H
E
IN
F O
R M
A T
IO
N
C O
N T
A
IN
T H
IS
D
R A
W
IN
G
IS
T
E
LL
E C
T U
A L
A N
D P
H Y
S
IC
A L
C O
P Y
R
IG
H T
P R
O P
E R
T Y
Y M
O N
D E
N G
IN
E
E R
IN
G
G E
O R
G
IA
IN
C
A
N D
M A
Y N
D U
P
LI
C A
T E
D
IN
P A
R T
O
O
LE
IN
A
N Y
M A
N N
LU
D
IN
G
IM
A
G
IN
G
E
LE
C T
R O
N
IC
S C
A N
N
IN
G
A P
H
IC
R E
P R
O D
U C
T
IO
N
N D
T R
A N
S F
E R
E , W
IT
H
O
E E
X P
R E
S S
W R
IT
T
R M
IS
S
IO
N
O F
T H
E A
U T
H O
R
R A
Y M
O N
D E
N G
IN
E
E R
IN
G
G E
O R
G
IA
IN
C
A
LL
R
IG
H
S E
R V
E D
, Y E
A R
A S
D A
T E
D
R A
Y M
O N
D P
R O
J E
C T
N O
C
O P
Y R
IG
H
T
G
R E
E N
S T
R E
E T
S E
S
U
IT
E A
C O
N Y
E R
S G
E O
R G
IA
-6
-2
R a ym o n d
E n g in ee ri n g
G eo rg ia
, I N
C
SHEET NO.:
OF
SHEETS
DESIGNED BY:
DRAWN BY:
CHECKED BY:
SUBMITTED BY:
ISSUE DATE:
P R
O J E
C T
T
IT
L E
P R
O J E
C T
A D
D R
E S
S
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
S T
A T
U S
S H
E E
T T
IT
L E
C O
N T
R A
C T
N O
R E
V
IS
IO
N
S
D E
S C
R
IP
T
IO
N D
A T
E R
E V
1234567
F ile
P a th
X
F
Y \1
\0
.C
A D
B
IM
\0 .0
.B
IM
P lo t D a te
/2
/2
:0 :3
P
M
J O
B
O R
L .0
A-003
02/24/2025
Approver
Designer
Author
Checker
R S
Q N o .2
-S
Q -1
L L
P R
O J N o P
C
B
ID
A N
D C
O N
S T
R U
C T
S E
T
S Y
M B
O L S
A N
D L
E G
E N
D S
W
E S
T I N
D
IA
N A
A V
E N
U E
D E
L A
N D
F
L
D E
L A
N D
I T
R E
S T
R O
O M
E N
E R
G Y
C O
N S
E R
V
M E
A S
U R
E S
B
ID
A N
D C
O N
S T
R U
C T
S E
TYPICAL MATERIALS STANDARD GRAPHICS AND SYMBOLSAR-GENERAL NOTES
L Rating At 400 F -less than I CFM/sq ft
L Rating At Ambient -less than 1 CFM/sq ft
T Ratings -0, 1,2,3, and 4 Hr (See Item 3)
F Ratings -1,2,3 and 4 Hr (See Items 2 and 3)
(Formerly System No- 147)
March 28,2003
System No. W-L-1001
Through-penetration Firestop Systems
RatingRatingor Conduit
+When copper pipe is used, T Rating is 0 h
3M COMPANY - CP 25WB+.
*Bearing the UL Classification Mark
Diam In
01 or 2
3 or 4
1 or 2
3 or 4
1 or 2
HrHr
3 or 4
0+, 1 or 2
Fill Void or Cavity Material* - Caulk
Max Pipe
WARD MFG INC
A BUNDY CO
TITEFLEX CORP
OMEGA FLEX INC
TF
Through-Penetrate
SECTION A-A
Wall Assembly
Gypsum Board*
Studs
FIRESTOP SYSTEM MC TYPE CABLE
MINNESOTA MINING & MFG. CO.- CP 5WB+. *BEARING THE UL CLASSIFICATION MARKING
AFC CABLE SYSTEMS INC.
SYSTEM No. W-L-3015 (FORMERLY SYSTEM No. 328)
L RATING AT AMBIENT - LESS THAN 1 CFM PER SQ FT. (SEE ITEM 3)
L RATING AT 400 F - LESS THAN 1 CFM PER SQ. FT. (SEE ITEM 3)
F RATING - 1 AND 2 HR. (SEE ITEM 3)
T RATINGS - 0, 3/4 AND 2 HR. (SEE ITEM 2)
3.
2.
1.
A
A
DECEMBER 15, 1998
SYSTEM No. W-L-3015
SECTION A - A
A.
B.
C.
CONSULT CURRENT UNDERWRITERS LABORATORIES "FIRE RESISTANCE DIRECTORY" FOR DETAILS
WALL ASSEMBLY - THE 1 OR 2 HR. FIRE RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING
CONSTRUCTION FEATURES:
FASTENERS - WHEN WOOD STUD FRAMING IS EMPLOYED, GYPSUM WALLBOARD ATTACHED TO STUDS WITH CEMENT COATED NAILS AS SPECIFIED IN THE INDIVIDUAL WALL OR PARTITION DESIGN. WHEN STEEL CHANNEL STUD FRAMING IS EMPLOYED, GYPSUM WALLBOARD ATTACHED TO STUDS WITH TYPE S SELF DRILLING, SELF TAPPING BUGLE HEAD STEEL SCREWS AS SPECIFIED IN THE INDIVIDUAL WALL OR PARTITION
DESIGN.
GYPSUM BOARD* - NOM 5/8 IN. THICK, 4 FT. WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, NUMBER OF LAYERS AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. MAX DIAM. OF OPENINGS CUT IN GYPSUM WALLBOARD IS 2 IN.
FILL, VOID OR CAVITY MATERIAL* - CAULK - CAULK FILL MATERIAL FORCED INTO ANNULAR SPACE AROUND ENTIRE CIRCUMFERENCE OF THROUGH PENETRATING PRODUCT TO COMPLETELY FILL OPENING IN GYPSUM
WALLBOARD ON EACH SIDE OF THE WALL ASSEMBLY. A MIN. 5/8 IN. THICKNESS OF CAULK IS REQUIRED FOR
THE 1 HR. F RATING, A MIN. 1-1/4 IN. THICKNESS OF CAULK IS REQUIRED FOR THE 2 HR. F RATING.
THROUGH PENETRATING PRODUCT* - MAX FOUR COPPER CONDUCTOR No. 2 AWG (OR SMALLER) ALUMINUM OR STEEL ARMORED CABLE OR METAL-CLAD CABLE, MAX ONE ARMORED CABLE OR METAL CLAD CABLE TO BE INSTALLED NEAR CENTER OF CIRCULAR OPENING IN GYPSUM WALLBOARD. THROUGH PENETRATING PRODUCT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. WHEN INSTALLED IN 1 HR. FIRE RATED WALL
ASSEMBLY, T RATING IS 0 HR. WHEN INSTALLED IN 2 HR. FIRE RATED WALL ASSEMBLY, T RATING IS 3/4 HR.
WHEN MAX No. 2 AWG CABLE IS USED AND 2 HR. WHEN MAX 12 AWG CABLE IS USED.
DIAM. OF CIRCULAR THROUGH OPENING CUT THROUGH GYPSUM WALLBOARD ON EACH SIDE OF WALL
ASSEMBLY TO BE MIN. 1/4 IN. TO MAX 11/16 IN. LARGER THAN DIAM. OF THROUGH PENETRATING
PRODUCT (ITEM 2) INSTALLED IN THROUGH OPENING. SIDE EDGE OF CIRCULAR OPENING TO BE MIN. 3 IN.
FROM NEAREST STUD IN WALL CAVITY.
STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. OC. WITH NOM 2 BY 4 IN. LUMBER END
PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN 3-5/8 IN. WIDE BY 1-3/8 IN. DEEP CHANNELS
SPACED MAX 24 IN. OC.
1. - The 1,2, 3 or 4 hr fire-rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner described in the individual U300 or U400 Series Wall or Partition Designs in the UL Fire Resistance Directory and shall include the following construction features:
A. - Wall framing may consist of either wood studs (max 2 h fire rated assemblies) or steel channel studs.
Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC with nom 2 by 4 in. lumber end plates and cross braces. Steel studs to be min 3-5/8 in. wide by 1-3/8 in. deep channels spaced max 24 in. OC.
2. - One metallic pipe, conduit or tubing installed either concentrically or eccentrically within the firestop system. The annular space between pipe, conduit or tubing and periphery of opening shall be min of 0 in. (point contact) to max 2 in. Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or tubing maybe used:
A. Steel Pipe - Nom 24 in. diam (or smaller) Schedule 10 (or heavier) steel pipe.
B. Iron Pipe - Nom 24 in. diam (or smaller) service weight (or heavier) cast iron soil pipe, nom 12 in diam (or smaller) or Class 50 (or heavier) ductile iron pressure pipe.
C. Conduit - Nom 6 in. diam (or smaller) steel conduit or nom 4 in diam (or smaller) steel electrical metallic tubing.
D. Copper Tubing - Nom 6 in. diam (or smaller) Type L (or heavier) copper tubing
E. Copper Pipe - Nom 6 in. diam (or smaller) Regular (or heavier) copper pipe.
F. Through Penetrating Product*- Flexible Metal Piping The following types of steel flexible metal gas piping may be used:
2. Nom I in. diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed on both sides of floor or wall assembly.
3. Nom I in. diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed on both sides of floor or wall assembly.
3. - Min 5/8. 1-1/4,1-7/8 and 2-1/2 in. thickness of caulk for I, 2,3 and 4 hr rated assemblies, respectively, applied within annulus, flush with both surfaces of wall. Min 1/4 in. diam bead of caulk applied to gypsum board/penetrate interface at point contact location on both sides of wall. The hourly F Rating of the firestop system is dependent upon the hourly fire rating of the wall assembly in which it is installed, as shown in the following table. The hourly T Rating of the firestop system is dependent upon the type or size of the pipe or conduit and the hourly fire rating of the wall assembly in which it is installed, as tabulated below:
1. Nom 2 in. diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed on both sides of floor or wall assembly.
B. -Nom or 5/8 in. thick, 4 ft. wide with square or tapered edges. The gypsum wallboard type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance Directory. Max diam of opening is 26 in.
A
A
1C
1A
1B
1A
1B
UL PENETRATIONS DETAILS
R A
Y M
O N
D
G
E
C
A
F
D
B
H
1 3 5 7 92 4 6 8 10 11
T H
E
IN
F O
R M
A T
IO
N
C O
N T
A
IN
T H
IS
D
R A
W
IN
G
IS
T
E
LL
E C
T U
A L
A N
D P
H Y
S
IC
A L
C O
P Y
R
IG
H T
P R
O P
E R
T Y
Y M
O N
D E
N G
IN
E
E R
IN
G
G E
O R
G
IA
IN
C
A
N D
M A
Y N
D U
P
LI
C A
T E
D
IN
P A
R T
O
O
LE
IN
A
N Y
M A
N N
LU
D
IN
G
IM
A
G
IN
G
E
LE
C T
R O
N
IC
S C
A N
N
IN
G
A P
H
IC
R E
P R
O D
U C
T
IO
N
N D
T R
A N
S F
E R
E , W
IT
H
O
E E
X P
R E
S S
W R
IT
T
R M
IS
S
IO
N
O F
T H
E A
U T
H O
R
R A
Y M
O N
D E
N G
IN
E
E R
IN
G
G E
O R
G
IA
IN
C
A
LL
R
IG
H
S E
R V
E D
, Y E
A R
A S
D A
T E
D
R A
Y M
O N
D P
R O
J E
C T
N O
C
O P
Y R
IG
H
T
G
R E
E N
S T
R E
E T
S E
S
U
IT
E A
C O
N Y
E R
S G
E O
R G
IA
-6
-2
R a ym o n d
E n g in ee ri n g
G eo rg ia
, I N
C
SHEET NO.:
OF
SHEETS
DESIGNED BY:
DRAWN BY:
CHECKED BY:
SUBMITTED BY:
ISSUE DATE:
P R
O J E
C T
T
IT
L E
P R
O J E
C T
A D
D R
E S
S
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
S T
A T
U S
S H
E E
T T
IT
L E
C O
N T
R A
C T
N O
R E
V
IS
IO
N
S
D E
S C
R
IP
T
IO
N D
A T
E R
E V
1234567
F ile
P a th
X
F
Y \1
\0
.C
A D
B
IM
\0 .0
.B
IM
P lo t D a te
/2
/2
:0 :3
P
M
J O
B
O R
L .0
A-004
02/24/2025
Approver
R S
Q N o .2
-S
Q -1
L L
P R
O J N o P
C
B
ID
A N
D C
O N
S T
R U
C T
S E
T
U L P
IP
E
P E
N E
T R
A T
IO
N
S
W
E S
T I N
D
IA
N A
A V
E N
U E
D E
L A
N D
F
L
D E
L A
N D
I T
R E
S T
R O
O M
E N
E R
G Y
C O
N S
E R
V
M E
A S
U R
E S
B
ID
A N
D C
O N
S T
R U
C T
S
PULL SIDE
FRONT APPROACHES
NOTE:
1. ALL DIMENSIONS SHOWN ARE MINIMUMS.
2. DIMENSIONS AND CLEARANCES SHOWN MUST
BE PROVIDED AT ALL DOORS.CONTRACTOR
SHALL REVIEW FIELD LAYOUT AND CONFIRM
THAT ALL OF THE APPROPRIATE CLEARANCES
ARE PROVIDED. ANY DISCREPANCIES SHALL BE
BROUGHT TO THE ARCHITECT'S ATTENTION.
ANY REMEDIAL WORK THAT SHOULD HAVE
BEEN AVOIDED BY BRINGING DISCREPANCIES
TO THE ARCHITECT'S ATTENTION SHALL BE AT
THE CONTRACTORS EXPENSE.
M
IN
IM
U
M
MIN
1' - 6"
M
IN
IM
U
M
BOTH A CLOSER AND LATCH
12" MINIMUM IF DOOR HAS
M
IN
IM
U
M
MINIMUM
3' - 0"
EXISTING BUILDING - VERIFY
3' - 6"
E X
IS
IN
G B
U
IL
D
IN
G
V E
R
IF
Y
M
IN
IM
U
M
M
IN
IM
U
M
MINIMUM
1' - 10"
A C
L O
S E
R A
N D
L A
T C
H
IF
D
O O
R H
A S
MINIMUM
2' - 0"
(ALL DOORS)
2'-8" CLEAR
PUSH SIDE PULL SIDE
HINGE SIDE APPROACHES
PUSH SIDE
PULL SIDE
LATCH SIDE APPROACHES
PUSH SIDE
DOORS IN A SERIES
FRONT APPROACH
DOORWAY W/O DOORS, SLIDING DOORS, AND FOLDING DOORS
SIDE APPROACH POCKET OR HINGE APPROACH STOP OR LATCH APPROACH
M
IN
IM
U
M
MINIMUM
1' - 10"
MINIMUM
2' - 0"
M
IN
IM
U
M
M
IN
IM
U
M
M
IN
IM
U
M
E X
IS
T
IN
G
B U
IL
D
IN
G
V
E R
IF
Y
M
IN
IM
U
M
IF
C
L O
S E
R I S
P R
O V
ID
E
D
M
IN
IM
U
M
M
IN
IM
U
M
IF
C
L O
S U
R E
I S
P R
O V
ID
E
D
M
IN
IM
U
M
M
IN
IM
U
M
MINIMUM
2' - 0"
E X
IS
T
IN
G
B U
IL
D
IN
G
V
E R
IF
Y
M
IN
IM
U
M
" 5' - 0" IN EXISTING BUILDINGS
5' - 4"
MINIMUM
4' - 0"
MINIMUM
4' - 0"
UNOBSTRUCTED FORWARD REACHUNOBSTRUCTED SIDE REACHOBSTRUCTED HIGH SIDE REACH OBSTRUCTED HIGH FORWARD REACH
M A
X
M A
X
MAX
10" >10" - 24" MAX
M A
X
M A
X
10" MAX
20" MAX
M A
X
>20" - 25" MAX
M
IN
M A
X
M A
X
R A
Y M
O N
D
G
E
C
A
F
D
B
H
1 3 5 7 92 4 6 8 10 11
T H
E
IN
F O
R M
A T
IO
N
C O
N T
A
IN
T H
IS
D
R A
W
IN
G
IS
T
E
LL
E C
T U
A L
A N
D P
H Y
S
IC
A L
C O
P Y
R
IG
H T
P R
O P
E R
T Y
Y M
O N
D E
N G
IN
E
E R
IN
G
G E
O R
G
IA
IN
C
A
N D
M A
Y N
D U
P
LI
C A
T E
D
IN
P A
R T
O
O
LE
IN
A
N Y
M A
N N
LU
D
IN
G
IM
A
G
IN
G
E
LE
C T
R O
N
IC
S C
A N
N
IN
G
A P
H
IC
R E
P R
O D
U C
T
IO
N
N D
T R
A N
S F
E R
E , W
IT
H
O
E E
X P
R E
S S
W R
IT
T
R M
IS
S
IO
N
O F
T H
E A
U T
H O
R
R A
Y M
O N
D E
N G
IN
E
E R
IN
G
G E
O R
G
IA
IN
C
A
LL
R
IG
H
S E
R V
E D
, Y E
A R
A S
D A
T E
D
R A
Y M
O N
D P
R O
J E
C T
N O
C
O P
Y R
IG
H
T
G
R E
E N
S T
R E
E T
S E
S
U
IT
E A
C O
N Y
E R
S G
E O
R G
IA
-6
-2
R a ym o n d
E n g in ee ri n g
G eo rg ia
, I N
C
SHEET NO.:
OF
SHEETS
DESIGNED BY:
DRAWN BY:
CHECKED BY:
SUBMITTED BY:
ISSUE DATE:
P R
O J E
C T
T
IT
L E
P R
O J E
C T
A D
D R
E S
S
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
S T
A T
U S
S H
E E
T T
IT
L E
C O
N T
R A
C T
N O
R E
V
IS
IO
N
S
D E
S C
R
IP
T
IO
N D
A T
E R
E V
1234567
F ile
P a th
X
F
Y \1
\0
.C
A D
B
IM
\0 .0
.B
IM
P lo t D a te
/2
/2
:0 :4
P
M
J O
B
O R
L .0
A-005
02/24/2025
Approver
Designer
Author
Checker
R S
Q N o .2
-S
Q -1
L L
P R
O J N o P
C
B
ID
A N
D C
O N
S T
R U
C T
S E
T
A D
A S
T A
N D
A R
D S
W
E S
T I N
D
IA
N A
A V
E N
U E
D E
L A
N D
F
L
D E
L A
N D
I T
R E
S T
R O
O M
E N
E R
G Y
C O
N S
E R
V
M E
A S
U R
E S
B
ID
A N
D C
O N
S T
R U
C T
S E
T
MANEUVERING CLEARANCES AT DOORS (ICC/ANSI-2017)
REACH RANGES
Refrigerator
W
T O
T A
L D
IS
T
F
T F
E
WOMEN
MEN
UNISEX
107A
JAN
KITCHEN
EXIST. VOID
EXIST.
EMPLOYEE
LOUNGE
6.2" 60"
EXIST. PAPER
SUPPLIES
EXIST. OFFICE
SUPPLIES
EXIST.
CORRIDOR
OPEN OFFICE
EXIST. LARGE
CONFERENCE
ROOM
ELEVATOR
EQUIPMENT
EXIST.
ELEVATOR
EXIST.
APPLICATIONS
DIRECTOR
EXIST.
ASSISTANT
DIRECTOR
EXIST.
DIRECTOR
SUPPLIES
EXIST.
TECHNICAL
DIRECTOR
EXIST.
DIRECTOR
EXIST. SMALL
CONFERENCE
EXIST. STAFF
ASSISTANT
EXIST.
INFORMATION
SERVICES
MANAGER
EXIST.
INFORMATION
SERVICES
MANAGER
EXIST.
INFORMATION
SERVICES
MANAGER
EXIST.
INFORMATION
SERVICES
MANAGER
EXIST. OFFICE
SUPPLIES
EXIST. PAPER
SUPPLIES
2.4" 34"
4.2" 60"
EXIST.
VESTIBULE
21T
117'-1 3/4"
143'-6 3/4"
12T
31T
MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING
TWO EXITS OR EXIT ACCESS DOORWAYS
ARE PLACED A DISTANCE APART EQUAL
TO NOT LESS THAN ONE-HALF OF THE
LENGTH OF THE MAXIMUM OVERALL
DIAGONAL DIMENSION OF THE BUILDING
T O
T A
L D
IS
T
F
T
T O
T A
L D
IS
T
F
T
3.8" 34"
WOMEN
MEN
CONFERENCE
JAN
1.6" 34"
EXISTING WORK
STATIONS
ROOM
EXISTING WORK
ROOM
EXISTING
OFFICE
ELEVATOR
STAIR
EXIST. ELECT
STOR
EXIST. OFFICE
EXIST.
TELEVISION
STUDIO
EXISTING
OFFICE
EXIST. SUPPLIES
EXIST. OFFICE
EXIST. STORAGE
EXIST. MEDIA
CLO
MEDIA
OLF
X.X" X.X"
OCCUPANT LOAD
REQ'D EGRESS WIDTH
EGRESS WIDTH
OL
OCCUPANT LOAD
TOTAL TRAVEL DISTANCE
1 HR WALL
LIFE SAFETY PLAN LEGENDS:
NOT IN SCOPE
LIMIT OF WORK
OT
OCCUPANT LOAD TOTAL
EXISTING EXIT SIGNS
OCCUPANCY LOAD CALCULATIONS
REFER TO SHEET A-001 FOR OCCUPANCY LOAD
CALCULATIONS AND PLUMBING CALCULATIONS
FBC 1007.1.1 TWO EXITS OR EXIT ACCESS
DOORWAYS ARE PLACED A DISTANCE APART
EQUAL TO NOT LESS THAN ONE-HALF OF THE
LENGTH OF THE MAXIMUM OVERALL DIAGONAL
DIMENSION OF THE BUILDING OR AREA TO BE
SERVED MEASURED IN A STRAIGHT LINE
BETWEEN THEM.
PROVIDED = 117 LF MIN. DISTANCE
FBC TABLE 1006.2.1 REQUIRED TRAVEL DISTANCE
FOR OL WITH SPRINKLER = 100
PROVIDED = 74 MAX FROM FURTHER POINT
R A
Y M
O N
D
PLAN N
TRUE
NORTH
G
E
C
A
F
D
B
H
1 3 5 7 92 4 6 8 10 11
T H
E
IN
F O
R M
A T
IO
N
C O
N T
A
IN
T H
IS
D
R A
W
IN
G
IS
T
E
LL
E C
T U
A L
A N
D P
H Y
S
IC
A L
C O
P Y
R
IG
H T
P R
O P
E R
T Y
Y M
O N
D E
N G
IN
E
E R
IN
G
G E
O R
G
IA
IN
C
A
N D
M A
Y N
D U
P
LI
C A
T E
D
IN
P A
R T
O
O
LE
IN
A
N Y
M A
N N
LU
D
IN
G
IM
A
G
IN
G
E
LE
C T
R O
N
IC
S C
A N
N
IN
G
A P
H
IC
R E
P R
O D
U C
T
IO
N
N D
T R
A N
S F
E R
E , W
IT
H
O
E E
X P
R E
S S
W R
IT
T
R M
IS
S
IO
N
O F
T H
E A
U T
H O
R
R A
Y M
O N
D E
N G
IN
E
E R
IN
G
G E
O R
G
IA
IN
C
A
LL
R
IG
H
S E
R V
E D
, Y E
A R
A S
D A
T E
D
R A
Y M
O N
D P
R O
J E
C T
N O
C
O P
Y R
IG
H
T
G
R E
E N
S T
R E
E T
S E
S
U
IT
E A
C O
N Y
E R
S G
E O
R G
IA
-6
-2
R a ym o n d
E n g in ee ri n g
G eo rg ia
, I N
C
SHEET NO.:
OF
SHEETS
DESIGNED BY:
DRAWN BY:
CHECKED BY:
SUBMITTED BY:
ISSUE DATE:
P R
O J E
C T
T
IT
L E
P R
O J E
C T
A D
D R
E S
S
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
S T
A T
U S
S H
E E
T T
IT
L E
C O
N T
R A
C T
N O
R E
V
IS
IO
N
S
D E
S C
R
IP
T
IO
N D
A T
E R
E V
1234567
F ile
P a th
X
F
Y \1
\0
.C
A D
B
IM
\0 .0
.B
IM
P lo t D a te
/2
/2
:0 :4
P
M
J O
B
O R
L .0
A-006
02/24/2025
Approver
Designer
Author
Checker
R S
Q N o .2
-S
Q -1
L L
P R
O J N o P
C
B
ID
A N
D C
O N
S T
R U
C T
S E
T
L
IF
E S
A F
E T
Y P
L A
N S
W
E S
T I N
D
IA
N A
A V
E N
U E
D E
L A
N D
F
L
D E
L A
N D
I T
R E
S T
R O
O M
E N
E R
G Y
C O
N S
E R
V
M E
A S
U R
E S
B
ID
A N
D C
O N
S T
R U
C T
S E
T
SCALE: 1/8" = 1'-0"A1
1ST FLOOR PLAN LIFE SAFETY
SCALE: 1/8" = 1'-0"E1
2ND FLOOR PLAN LIFE SAFETY
SCALE: = 1'-0"
0 8 168
1/8"
W
EXIST. PAPER
SUPPLIES
EXIST. VOID
MEN
EXIST.
TECHNICAL
DIRECTOR
ELEVATOR
EQUIPMENT
EXIST.
VESTIBULE
EXIST.
ELEVATOR
EXIST.
APPLICATIONS
DIRECTOR
EXIST.
ASSISTANT
DIRECTOR
EXIST.
DIRECTOR
SUPPLIES
EXIST.
DIRECTOR
EXIST. SMALL
CONFERENCE
EXIST. STAFF
ASSISTANT
EXIST.
INFORMATION
SERVICES
MANAGER
EXIST.
INFORMATION
SERVICES
MANAGER
EXIST.
INFORMATION
SERVICES
MANAGER
EXIST. LARGE
CONFERENCE
ROOM
EXIST. PAPER
SUPPLIES
EXIST. OFFICE
SUPPLIES
EXIST.
INFORMATION
SERVICES
MANAGER
EXIST.
EMPLOYEE
LOUNGE
KITCHEN
OPEN OFFICE
EXIST. OFFICE
SUPPLIES
Room
EXIST.
CORRIDOR
CORRIDOR
WOMEN
LIMIT OF WORK
EXISTING CONDITIONS NOTES:
1. THIS DRAWING (ALONG WITH THE EXISTING CONDITIONS PLANS) IS PROVIDED
TO ILLUSTRATE EXISTING CONDITIONS INTO WHICH THE DESIGN WILL BE
INCORPORATED AND TO INDICATE PRIMARY ARCHITECTURAL DEMO WORK
REQUIRED TO ACHIEVE THE NEW DESIGN.
2. THIS DRAWING SHOULD NOT BE CONSTRUED AS AN "AS-BUILT" DRAWING OR A
COMPREHENSIVE RECORD OF ALL CONDITIONS THAT WILL IMPACT
INSTALLATION OF THIS DESIGN, NOR SHOULD IT BE UNDERSTOOD TO BE A
COMPLETE INDICATION OF ALL ITEMS REQUIRED TO BE REMOVED OR
DEMOLISHED IN ORDER TO EXECUTE THIS DESIGN.
3. REFER TO APPLICABLE ENGINEERING DRAWINGS FOR DESCRIPTION OF
EXISTING CONDITIONS AND DEMO WORK RELATED TO MECHANICAL, PLUMBING,
ELECTRICAL, OR OTHER UTILITY DISCIPLINES.
4. THE CONTRACTOR'S BID PRICE IS TO ACCURATELY REFLECT ANY SUCH
APPLICABLE CONDITIONS.
5. IT IS THE CONTRACTOR'S RESPONSIBILITY TO EXAMINE THE SITE PRIOR TO BID
AND CONSTRUCTION TO CONFIRM AND VERIFY EXISTING CONDITIONS AND
DETERMINE THE FOLLOWING:
6. IF ANY ADDITIONAL DEMOLITION WORK WILL BE REQUIRED TO ACHIEVE THIS
DESIGN
7. IF EXISTING ELEMENTS, UTILITIES, BUILDING FEATURES, ETC. WILL INTERFERE
WITH THE EXECUTION OF THIS DESIGN AS SHOWN.
8. IF ANY OF THE EXISTING CONDITIONS, MATERIALS, UTILITIES, OR OTHER ITEMS
CAN BE USED (OR REUSED) AND INCORPORATED INTO THIS DESIGN.
GENERAL DEMOLITION NOTES:
1. REFER TO SPECIFICATIONS (GENERAL REQUIREMENTS) FOR ADDITIONAL
INFORMATION RELATED TO DEMOLITION / PATCH / REPAIR WORK AND
CONTRACTOR RESPONSIBILITIES.
2. DURING THE EXECUTION OF THE WORK, PRIMARY CONSIDERATION SHALL BE
GIVEN TO THE PROTECTION FROM DAMAGE TO THE STRUCTURE, EQUIPMENT,
WALL FINISHES, AND THE LIKE WHICH ARE NOT SPECIFICALLY INDICATED TO BE
REMOVED AND DISPOSED. DAMAGE AS A RESULT OF THIS WORK TO THE
EXISTING ITEMS OR SURFACES TO REMAIN, SHALL BE REFINISHED, REPAIRED
OR REPLACED, TO THE SATISFACTION OF THE ARCHITECT AND OWNER, AT NO
ADDITIONAL COST TO THE OWNER.
3. AREAS IN WHICH DEMOLITION AND SALVAGE WORK IS BEING DONE SHALL BE
CLEANED DAILY. ALL DIRT, DUST DEBRIS, UNSALVAGEABLE, AND UNREUSEABLE
ITEMS SHALL BE TOTALLY REMOVED FROM THE PROJECT SITE DAILY.
4. DURING REMOVAL OF ITEMS BEING SALVAGED, CAUTION SHALL BE USED TO
ELIMINATE POSSIBILITY OF DAMAGE TO SUCH ITEMS. ALL REUSABLE ITEMS
SALVAGED DURING DEMOLITION OPERATIONS SHALL BE RETAINED FOR THE
OWNER'S INSPECTION. ONLY ITEMS PROPERLY INSPECTED AND REJECTED BY
THE OWNER SHALL BE DISPOSED. ALL OTHER ITEMS SHALL BE TURNED OVER
TO THE OWNER FOR DISPOSITION.
5. WHERE ELEMENTS ARE SCHEDULED TO BE REMOVED THAT MAY CONTAIN
EXISTING POWER, WIRING, OUTLETS, LIGHTING, SWITCHES, OR OTHER
DEVICES OR COMPONENTS, G.C. IS TO TAKE CARE TO PROPERLY AND
ADEQUATELY REMOVE, RELOCATE OR DISABLE ELEMENTS NOT NECESSARY
FOR STORE OPERATION. THIS ALSO APPLIES TO REMOVAL OF ITEMS
CONTAINING PLUMBING OR OTHER UTILITY COMPONENTS THAT WILL NEED TO
BE PROPERLY DISABLED OR "CAPPED".
6. WHERE FLOOR, WALL OR CEILING ITEMS ARE REMOVED, G.C. IS TO PATCH,
REPAIR, RECONSTRUCT OR OTHERWISE PREP AFFECTED AREA TO RECEIVE
NEW MATERIALS OR FINISHES AS INDICATED IN THESE PLANS.
7. IF REQUIRED, CUT/REMOVE CEILING MATERIAL AS NECESSARY TO
ACCOMMODATE ANY ABOVE-CEILING UTILITY WORK INDICATED ON MEP OR FIRE
PROTECTION DRAWINGS.
DEMO PLAN LEGEND:
EXISTING WALL TO REMAIN
EXISTING WALL TO BE REMOVED
NOT IN SCOPE
LIMIT OF WORK
R A
Y M
O N
D
PLAN N
TRUE
NORTH
G
E
C
A
F
D
B
H
1 3 5 7 92 4 6 8 10 11
T H
E
IN
F O
R M
A T
IO
N
C O
N T
A
IN
T H
IS
D
R A
W
IN
G
IS
T
E
LL
E C
T U
A L
A N
D P
H Y
S
IC
A L
C O
P Y
R
IG
H T
P R
O P
E R
T Y
Y M
O N
D E
N G
IN
E
E R
IN
G
G E
O R
G
IA
IN
C
A
N D
M A
Y N
D U
P
LI
C A
T E
D
IN
P A
R T
O
O
LE
IN
A
N Y
M A
N N
LU
D
IN
G
IM
A
G
IN
G
E
LE
C T
R O
N
IC
S C
A N
N
IN
G
A P
H
IC
R E
P R
O D
U C
T
IO
N
N D
T R
A N
S F
E R
E , W
IT
H
O
E E
X P
R E
S S
W R
IT
T
R M
IS
S
IO
N
O F
T H
E A
U T
H O
R
R A
Y M
O N
D E
N G
IN
E
E R
IN
G
G E
O R
G
IA
IN
C
A
LL
R
IG
H
S E
R V
E D
, Y E
A R
A S
D A
T E
D
R A
Y M
O N
D P
R O
J E
C T
N O
C
O P
Y R
IG
H
T
G
R E
E N
S T
R E
E T
S E
S
U
IT
E A
C O
N Y
E R
S G
E O
R G
IA
-6
-2
R a ym o n d
E n g in ee ri n g
G eo rg ia
, I N
C
SHEET NO.:
OF
SHEETS
DESIGNED BY:
DRAWN BY:
CHECKED BY:
SUBMITTED BY:
ISSUE DATE:
P R
O J E
C T
T
IT
L E
P R
O J E
C T
A D
D R
E S
S
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
S T
A T
U S
S H
E E
T T
IT
L E
C O
N T
R A
C T
N O
R E
V
IS
IO
N
S
D E
S C
R
IP
T
IO
N D
A T
E R
E V
1234567
F ile
P a th
X
F
Y \1
\0
.C
A D
B
IM
\0 .0
.B
IM
P lo t D a te
/2
/2
:0 :5
P
M
J O
B
O R
L .0
AD-101
02/24/2025
Approver
Designer
Author
Checker
R S
Q N o .2
-S
Q -1
L L
P R
O J N o P
C
B
ID
A N
D C
O N
S T
R U
C T
S E
T
S
T F
L O
O R
D E
M
L A
N
W
E S
T I N
D
IA
N A
A V
E N
U E
D E
L A
N D
F
L
D E
L A
N D
I T
R E
S T
R O
O M
E N
E R
G Y
C O
N S
E R
V
M E
A S
U R
E S
B
ID
A N
D C
O N
S T
R U
C T
S E
T
SCALE: 3/16" = 1'-0"A1
1ST FLOOR PLAN DEMO
KEYNOTE LEGEND
1 DEMOLISH PORTION OF EXISTING PARTITION.
2 REMOVE EXISTING DOORS AND/OR FRAMES, COMPLETE WITH ALL FASTENERS
AND APPURTENANCES, WHERE INDICATED OR REQUIRED TO COMPLETE THE
NEW WORK. EXISTING DOORS TO REMAIN SHALL BE PROTECTED FROM DAMAGE
BY CONSTRUCTION ACTIVITIES.
3 REMOVE EXISTING PARTITION TO EXPOSE EXISTING WINDOW.
4 REMOVE EXISTING TOILET PARTITIONS AND ANY SUPPORT STRUCTURES,
COMPLETE WITH ALL APPURTENANCES.
5 REMOVE EXISTING URINAL SCREEN.
6 REMOVE EXISTING TOILET FIXTURES INCLUDING ANY CARRIERS AND OTHER
APPURTENANCES.
7 REMOVE EXISTING VANITY COUNTER.
8 REMOVE EXISTING TOILET ACCESSORIES, GRAB BARS, AND ANY OTHER
APPURTENANCES, COMPLETE.
9 REMOVE EXISTING BASE AND WALL CABINETS.
10 REMOVE EXISTING APPLIANCES AND PROVIDE NEW SS OF LIKE
CONFIGURATION.
EXISTING REFRIGERATOR
AREA. ROOM 114
EXISTING OVERALL KITCHEN VIEW. ROOM 114 EXISTING 2ND MICROWAVE LOCATION. ROOM 114
Remove and install New wall and base cabinets, sink and Diswasher
EXISTING WATER HEATER LOCATION. ROOM 108
Relocate Existing Water heater
Remove ceiling panels, light fixtures, carpet and cabinets
EXISTING MEN RESTROOM. ROOM 111
Existing window to remain
Remove plumbing fixtures
Remove plumbing fixtures, urinal screen, flooring, ceiling panels, light fixtures.
EXISTING ROOM 114
Remove and Replace lavatories, mirror flooring,light fxitures and ceiling.
Remove and Replace toilet partitions flooring,light fxitures and ceiling.
EXISTING ROOM 107
Remove light fxitures and ceiling.Remove sections of cabinets and coordinate with owner for repurposing or disposal
SCALE: = 1'-0"3/16"
0 4 8 124
Contractor to remove and dispose of the existing appliaces and provide new stainless-steel appliances of like configuration.
• Refrigerator
• Microwave
• Dishwasher
UP
EXIST. OFFICE
EXIST. SUPPLIES
EXISTING WORK
STATIONS
ROOM
STOR
CONFERENCE
WOMEN
MEN
STORAGE
EXISTING
OFFICE
JAN
EXIST. ELECT
EXIST. MEDIA
MEDIA
EXISTING WORK
ROOM
EXIST. OFFICE
ELEVATOR
102STAIR
LIMIT OF WORK
EXISTING CONDITIONS NOTES:
1. THIS DRAWING (ALONG WITH THE EXISTING CONDITIONS PLANS) IS PROVIDED
TO ILLUSTRATE EXISTING CONDITIONS INTO WHICH THE DESIGN WILL BE
INCORPORATED AND TO INDICATE PRIMARY ARCHITECTURAL DEMO WORK
REQUIRED TO ACHIEVE THE NEW DESIGN.
2. THIS DRAWING SHOULD NOT BE CONSTRUED AS AN "AS-BUILT" DRAWING OR A
COMPREHENSIVE RECORD OF ALL CONDITIONS THAT WILL IMPACT
INSTALLATION OF THIS DESIGN, NOR SHOULD IT BE UNDERSTOOD TO BE A
COMPLETE INDICATION OF ALL ITEMS REQUIRED TO BE REMOVED OR
DEMOLISHED IN ORDER TO EXECUTE THIS DESIGN.
3. REFER TO APPLICABLE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .