This solicitation announcement is for the "Oahe Switchyard Disconnect Switch Replacement" project being conducted by the U.S. Army Corps of Engineers Omaha District. The project involves replacing high voltage disconnect switches, steel switch supports, suspension insulators, and buses in the 115kV and 230kV switchyards at Oahe Dam in Pierre, South Dakota. An estimated 60 inches of weld repair will also be conducted on aluminum main and auxiliary buses following an inspection. Feeder and control cables will be replaced for new motor-operated disconnect switches. The contractor must commence work upon contract award and complete the project within 730 calendar days of receiving the notice to proceed, with the solicitation closing on July 6, 2023. The estimated construction cost ranges from $5 million to $10 million. The primary NAICS code is 237130 for power and communication line structure construction with a small business size standard of $45 million.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

G2hdcrcs

FOR INFORMATION ONLY

Text Box

MO521 - 83E378

06---Sep 2022 - 90% Oahe Switchyard Disconnecte Reference Drawings .pdf
CY_MO57_81E1102.1
CY_MO57_81E1104.1
CY_MO57_81E1106.2
CY_MO57_81E1108.2
CY_MO57_81E1110.1
CY_MO57_81E1112.1
CY_MO57_81E1114.2
CY_MO57_81E1116.1
CY_MO57_81E1118.2
GE 0109B2258 (115 kV RF-2 Sw)
GE 0109B2259 (230 kV RF-2 Sw)
GE 0131F0745 (230 kV RF-2 Sw Stands)
GE 0131F0746 (115 kV RF-2 Sw Stands)
GE 0138A9325 (Key Interlock w MOD)
GE 0138A9326 (Key Interlock wo MOD)
GE 0866C0392 (230 kV Gnd Sw)
GE 0866C0393 (115 kV Gnd Sw)
GE 0866C0394 (230 kV RF-2 Sw Man Op Mech)
GE 0866C0396 (230 kV Gnd Sw Man Op Mech )
GE 0866C0397 (115 kV RF-2 Sw Man Op Mech)
GE 0866C0398 (115 kV Gnd Sw Man Op Mech)
MO67-86E107.1
MO67-86E108.1
MO67-86E109.1
MO67-86E110.1
MO381_83E540
MO381_83E541
MO381-83E362.1
MO381-83E372.2 PPCS & RTU Eagle Butte DC_(MOD 1267)
MO381-83E376.2_install_(MOD 2387)
MO381-83E379_install_(MOD 2787)
MO381-83E380.2 install_(MOD 2987)
MO521-83E378
MO-OPN80E103
MO-OPN80E105
MO-OPN-83E355.2
MO-OPN-83E356.3
MO-OPN-83E358.3
MO-OPN-83E371.2
MO-OPN-83E373.5B_(MOD 1467)
MO-OPN83E377.3 Sully Buttes DC Control_(MOD 2587)
MO-OPN-83E381.2 install_(MOD 3087)
MO-OPN84E113.1
MO-OPN93E103.4
MO-OPN-93E104
MO-OPN-93E105
MO-OPN-93E107
MO-OPN93E502.2
MO-OPN93E503
MO-OPN93E504
MO-OPN93E505
MO-OPN93E508
MO-OPN93E509
MO-OPN93E510
OA69_E_06_1_01_102A_ODP_C
OA69_E_06_1_01_102B_ODP_C
OA69_E_06_1_01_102C_ODP_C
OA69_E_06_1_01_104_ODP_C
OA69_E_06_1_01_106A_ODP_C
OA69_E_06_1_01_404_ODP_C
OA69_E_06_1_01_405_ODP_C
OA69_E_06_1_01_604_ODP_C
OA69_E_06_1_01_605_ODP_C
OA69_E_06_1_01_606_ODP_C
OA69_G_00_1_01_101_ODP_C