General Asbestos Survey for Asbestos-Containing Materials
Prepared for:
Marshall Space Flight Center, AL
Building 4759 Marshall Space Flight Center
GSE - 013
October 31, 2008
Prepared by
Great Southern Engineering, Inc.
3795 Gordon Terry Parkway
Trinity, Alabama 35673
TABLE OF CONTENTS
1. Introduction
2. Summary
2.1. Suspect ACMs
2.2. Recommendations
3. Survey Scope
4. Limitations
5. Survey and Sample Collection Procedure
6. Previous Survey / Plans Review
7. Suspect ACM Materials Not Sampled
8. Survey Sampling Results
9. Appendices
Task Order GSE 013 Page 1 of 27
GENERAL ASBESTOS SURVEY OF
Building 4759, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama
1. Introduction
In accordance with GSE Task Order No.GSE-013 dated April 21, 2008, Great Southern Engineering, Inc. (GSE) has performed an asbestos survey of Building 4759 located at George C.
Marshall Space Flight Center, Marshall Space Flight Center, Alabama. The 8,540 square feet building was identified to have been originally constructed in 1961. A total of 36 samples were collected from the building.
The objective of the Asbestos Survey is to determine the location and quantity of asbestos-containing materials at the Property building.
GSE’s Scope of Work included:
Visual inspection and identification of suspect asbestos-containing materials (ACMs) in the Property building and collected a representative number of samples for analysis.
As part of this asbestos survey, GSE personnel collected samples of all suspect friable and suspect damaged non-friable building materials at the Property. The remaining suspect non-friable materials were not be sampled as part of this asbestos survey
Estimated quantities and locations of ACM.
Assessed the condition of the ACM identified.
Assigned a hazard rating to each type of ACM.
This report has been prepared for the use of George C. Marshall Space Flight Center. Our investigation was performed using the degree of care and skill ordinarily exercised under similar circumstances by professional consultants practicing in this or similar localities. No other warranty or guarantee, expressed or implied, is made as to the conclusions included in this report.
Task Order GSE 013 Page 2 of 27
Building 4759, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama
The GSE, Inc. did not perform destructive sampling procedures at the site; therefore, regardless of the thoroughness of this survey, it is possible that suspected asbestos-containing materials (ACMs) might exist in the building beneath the floors, behind walls, within pipe chases, or in other inaccessible locations. If, during renovation or demolition activities, materials not addressed in this survey are discovered, these materials should be sampled and analyzed for asbestos content prior to disturbance.
Surveyed by:
Jeff R Smith
University of Alabama Safe State Program Accredited Inspector/Management Planner
Accreditation #APL0408S7033
Written by:
Manju Ramasamudra
University of Alabama Safe State Program Accredited Inspector/Management Planner
Accreditation #APL0308R5089
Task Order GSE 013 Page 3 of 27
Building 4759, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama
2. Summary
GSE performed an Asbestos Survey and Hazard Assessment at Building 4759 in Marshall Space Flight Center, Alabama on July 25, 26 and September 30, 2008. Sample collection was completed by licensed personnel – Jeff R Smith. The following report summarizes the independent conclusions representing GSE’ best professional judgment based on information and data available to us during the course of this survey. Factual information regarding operations, conditions, and tests data provided by the client, owner or their representative has been assumed to be correct and complete. Additionally, the conclusions presented are based on the conditions that existed on the date(s) of the assessment.
The 8,540 square feet building was identified to have been originally constructed in 1961. A total of 36 samples were collected from the building. Two (2) Homogeneous materials were identified as asbestos-containing materials. A summary of the samples collected for this area and corresponding analytical results is presented below.
Sample Description
Sample
ID
Building Number
Sample Material
ACM
Quantity
4759 16 Pipe Insulation With Cotton Wrap 450 LF
Room Number Grid Numbers 200 F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4
101 F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4
105 F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4
102A F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4
102 F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4
Sample Description
Sample
ID
Building Number
Sample Material
ACM
Quantity
4759 21 Pipe Insulation Elbow and Fitting Insulation 100 Elbows
Room Number Grid Numbers 200 F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4
102 F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4
105 F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4
101 F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4
102A F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4
WL1-1
WR2-1
WR1-1
WL3-1
WL2-1
WR4-1
WR3-1
F1-1 F2-1 F3-1 F4-1
C1-1 C2-1 C3-1 C4-1
C1-2
C1-3
C1-4
C2-2
C2-3
C2-4
C3-2
C3-3
C3-4
C4-2
C4-3
C4-4
WR4-2
WR4-3
WR4-4
WR3-2
WR3-3
WR3-4
WR2-2
WR2-3
WR2-4
WR1-2
WR1-3
WR1-4
F4-2
F4-3
F4-4
F3-2
F3-4
F2-2
F2-3
F2-4
F1-2
F1-3
F1-4
WL1-2
WL1-3
WL1-4
WL2-2
WL2-3
WL2-4
WL3-2
WL3-3
WL3-4
WL4-2
WL4-3
WL4-4
F3-3
WL4-1
WF4-1 WF4-2 WF4-3 WF4-4
WF3-1
WF2-1
WF1-1
WF3-2
WF2-2
WF1-2
WF3-3
WF2-3
WF1-3
WF3-4
WF2-4
WF1-4
WE4-1WE4-2WE4-3WE4-4
WE3-1
WE2-1
WE1-1
WE3-2
WE2-2
WE1-2
WE3-3
WE2-3
WE1-3
WE3-4
WE2-4
WE1-4
Map Document: (G:\asbestos\Asbestos_Room_grid.mxd)
1. Note: Entry wall depicted is as seen from inside the room, therefore grid WE4-4 is located at the top left corner of wall. The main entry door is located within the entry wall.
2. Entry wall location shall be described as N (North) S (South) E (East) or W (West) as seen from the inside of the room. Utilizing the facilities data book, N is located at the top of page, S at bottom of page, E at right of page and W and left of page regardless of bearing shown on drawing for all buildings. (The directional bearing symbol is pointing to either NE or NW for approximately 29 buildings in the facilities data book. Consider these NE or NW bearings as being Plan N when identifying the direction of the entry wall.)
The only exception is building 4705, this drawing shall be oriented towards North as shown on drawing.
3. Type of grid system uses 4 grids by length and 4 grids by width irrespective of the room size.
Grid: C - ceiling, WF - far wall, WE - entry wall, WL - left wall, WR - right wall, F - floor
Asbestos Survey Room Grid Note: Asbestos containing material above the ceiling should be noted on the ceiling grid
Far Wall Entry Wall
Far Wall
WL1-1
WR2-1
WR1-1
WL3-1
WL2-1
WR4-1
WR3-1
WR4-2
WR4-3
WR4-4
WR3-2
WR3-3
WR3-4
WR2-2
WR2-3
WR2-4
WR1-2
WR1-3
WR1-4
WL1-2
WL1-3
WL1-4
WL2-2
WL2-3
WL2-4
WL3-2
WL3-3
WL3-4
WL4-2
WL4-3
WL4-4
WL4-1
C1-1 C2-1 C3-1 C4-1
C1-2
C1-3
C1-4
C2-2
C2-3
C2-4
C3-2
C3-3
C3-4
C4-2
C4-3
C4-4
WF4-1 WF4-2 WF4-3 WF4-4
WF3-1
WF2-1
WF1-1
WF3-2
WF2-2
WF1-2
WF3-3
WF2-3
WF1-3
WF3-4
WF2-4
WF1-4
WE4-1WE4-2WE4-3WE4-4
WE3-1
WE2-1
WE1-1
WE3-2
WE2-2
WE1-2
WE3-3
WE2-3
WE1-3
WE3-4
WE2-4
WE1-4
F1-1 F2-1 F3-1 F4-1
F4-2
F4-3
F4-4
F3-2
F3-4
F2-2
F2-3
F2-4
F1-2
F1-3
F1-4
F3-3
Map Document: (G:\asbestos\Asbestos_Hall_grid.mxd)
1. Note: Entry wall and far wall are optional; there maybe neither that are identified in the hallway. Entry wall depicted is as seen from inside the room, therefore grid WE4-1 is located at the top left corner of wall.
2. Type of grid system uses 4 grids by length and 4 grids by width irrespective of the hall size.
3. The identification of hallway segments will be determined by the end rooms. Hallways will be measured from South to North and from East to West Ex. Room most south of hallway is Room 107 and room most North of hallway is Room 200. Using H as the designation of hallway. The identification of hallway is HS107N200. Likewise from east to west would be HE107W200. The room number sequencing is arbitrary; Ex. HE200W107 would be acceptable. NS&EW are used to distinguish between vertical and horizontal run corridors on drawings.
4. Utilizing the facilities data book, N is located at the top of page, S at bottom of page, E at right of page and W and left of page regardless of bearing shown on drawing for all buildings. (The directional bearing symbol is pointing to either NE or NW for approximately 29 buildings in the facilities data book. Consider these NE or NW bearings as being Plan N when identifying the hallway number.) The only exception is building 4705, this drawing shall be oriented towards North as shown on drawing.
Grid: C - ceiling, WF - far wall, WE - entry wall, WL - left wall, WR - right wall, F - floor
Asbestos Survey Hallway Grid Note: Asbestos containing material above the ceiling should be noted on the ceiling grid
Far Wall Entry Wall
Far Wall Room XXXBeginning
Room YYY N or W
S or E
Task Order GSE 013 Page 4 of 27
Building 4759, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama
2.1. Suspect ACMs
The following information is included for informational purposes:
A. The following suspect asbestos-containing materials were not sampled as part of this scope of work:
Suspect fibrous electrical cable covering (danger of electrocution) were not sampled.
These materials are not subject to regulation under NESHAP for demolition and renovation as long as they are in good condition and are not subject to sanding, grinding, cutting, or abrading.
Since ordinary demolition activities do not include sanding, grinding, cutting, and abrading, these materials may remain in place during building demolition, as long as they remain in good condition and are not friable.
If the material is in poor condition and is friable at the time of demolition or renovation, or if it will be subjected to sanding, grinding, cutting, or abrading, it should first be removed by a licensed asbestos removal contractor and disposed of as asbestos-containing waste.
When removing asphalt-roofing products, the material should be removed using a method that does not subject the material to sanding, cutting, grinding, or abrading (hand tools).
Asbestos-containing roofing may be disposed of as construction debris.
Task Order GSE 013 Page 5 of 27
Building 4759, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama
2.2. Recommendations
The following additional actions are recommended:
The identified asbestos-containing Pipe Insulation and associated Elbow insulations are in damaged condition. MSFC (Property owner/Operator) should develop and implement an Operations and Maintenance (O&M) Program. In addition suspect asbestos-containing materials in the form of Caulking on exterior walls, electrical cable covering, fire doors, window caulking, mirror mastic, Leveling Compound Below ceramic tile flooring, and duct vibration joints were not sampled as a part of this assessment. These materials can be maintained as part of the asbestos O&M Program. A properly designed O&M Program is sufficient to maintain the Project in accordance with current regulatory standards and sound business practice. ACM maintained with an O&M Program can remain in place, provided the ACM and suspect ACM remain intact and undisturbed.
Repair or removal of damaged asbestos-containing materials by a licensed asbestos contractor in accordance with all applicable federal, state, and local regulations. If any ACM remains after removal, then an Asbestos O&M Program should be developed and implemented.
Task Order GSE 013 Page 6 of 27
Building 4759, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama
3. Survey Scope
This survey was conducted for the purpose of identifying asbestos-containing materials (ACM) throughout the building and to conduct a hazard assessment on existing ACM. The survey was non-destructive in nature and limited only to those areas that were readily accessible.
Specific areas to which access was limited by occupant request, unavailability of keys, or by site conditions included the following:
Behind the walls
Beneath the floors
Any suspect ACM not sampled as part of the assessment and if any additional suspect materials were to be identified behind walls and beneath the floors should be sampled prior to repair, renovation, or demolition activities.
Task Order GSE 013 Page 7 of 27
Building 4759, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama
4. Limitations
GSE did not attempt to disassemble mechanical equipment, open pipe chases or assess materials within wall voids. Regardless of the thoroughness of a survey, the possibility exists that some areas containing asbestos were not identified, inaccessible or different from those at specific locations. The findings and opinions presented are relative to the dates of our site work and should not be relied upon to represent conditions at substantially later dates due to changes in the condition ACM may change over time, renovations and repairs.
This report is for the exclusive use of the client and its agents and use by any unauthorized parties in whole or in part, except as directed by legal jurisdiction, is at the sole risk of the user.
If this assessment includes reliance on work products and/or documents prepared by others, GSE has no responsibility for the accuracy of information contained therein.
Although this assessment has attempted to identify the presence or absence of ACM, potential sources of ACM may have escaped detection due to: (1) the scope of this assessment, (2) the inaccuracy of records, interviews, work products or documents made available to GSE for this report, (3) the presence of undetected or unreported renovations and repairs, (4) inaccessible areas, and/or (5) deliberate concealment of detrimental information.
Estimates presented in this report are based upon observations during the survey and owner-provided information. These reasonable estimates may be affected by unanticipated conditions potentially present in inaccessible or un-surveyed areas. GSE does not warrant or guarantee the quantity estimates. The use of such estimates shall be at the user's own risk and shall constitute a release and agreement to defend and indemnify GSE from and against any liability. If questions arise during the planning for renovation, demolition, or other construction activities, GSE should be notified to permit review of the data and present recommendations.
Interior of the following rooms were inaccessible during our Asbestos Survey on July 25, 26 and September 30, 2008: None.
Task Order GSE 013 Page 8 of 27
Building 4759, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama
5. Survey and Sample Collection Procedure
Based on United States Environmental Protection Agency (USEPA) guidance documents, GSE considered all material applications identified during the visual assessment were suspect ACM and sampled as described below.
Bulk samples were collected of any materials, which were suspected of containing asbestos with the exception of fire doors. Fire doors were not sampled because the damage caused by sampling would render these materials friable and may also void the fire rating. Since these materials were not sampled, they should be assumed to be asbestos containing, unless sampled and proven otherwise. Sampling of these assumed ACMs should be performed prior to any renovation or other activity that may cause a material disturbance.
Samples of the remaining suspect ACM were taken in accordance with USEPA recommendations.
The number and location of samples collected was based on the type of material, the manner of application, and the homogeneity of the ACM (similarity of color, texture, and type). Each sample was collected and placed into an individual sample container. The sample location was noted on the field survey form and assigned an individual identification number. This number was affixed to the sample container as the sample was collected. The survey form was also used to note the material type and general condition of the material. During the inspection, each suspect material's accessibility, location, and friability were recorded. This information was used to assess the potential hazard of the ACM and to prioritize response action recommendations.
The USEPA defines asbestos-containing materials (ACM) as those that contain greater than one percent asbestos. Friable materials are defined as those that can be crumbled or reduced to powder by hand pressure.
GSE utilized the “positive-stop” method of sample analysis. In this method, analysis is stopped on a group of samples once the first positive (e.g., greater than 1% asbestos) sample is analyzed.
According to the USEPA, if one sample of a homogenous material is identified to be asbestos containing, the entire material must be considered asbestos containing. By using the positive-stop method, GSE reduces the Client’s laboratory analysis cost by not analyzing the additional samples.
Samples collected were carried and submitted under Chain-of-Custody to Steve Moody Micro Services LLC, Farmers Branch, Texas for analysis of asbestos using USEPA Method 40 CFR, Chapter 1, Part 763, Subpart F, Appendix A, also known as Polarized Light Microscopy (PLM).
Steve Moody Micro Services LLC is certified by the National Voluntary Laboratory Accreditation Program (NVLAP) and licensed by the Department of State Health Services.
Task Order GSE 013 Page 9 of 27
Building 4759, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama
6. Previous Survey / Plans Review
GSE was not provided with any previously conducted asbestos surveys of the Property. As-built/renovation-site plans and construction drawings were reviewed at the Facilities Department Drawing Room. Review of these documents did not identify building material specifications requiring the use of ACM. However, this does not preclude or prevent the potential use of ACM.
Task Order GSE 013 Page 10 of 27
Building 4759, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama
7. Suspect ACM Materials Not Sampled
During the course of the property visit, GSE performed a preliminary review of interior, accessible areas of the subject building for the presence of suspect asbestos-containing materials (ACMs). This asbestos survey was conducted for overview purposes only; additional suspect materials may exist in concealed locations (behind walls and above ceilings, beneath the floors, within machinery, etc.). Also, not all suspect materials may have been sampled due to the condition or the location of the suspect materials. Destructive sampling of suspect ACMs was not performed. GSE will not be responsible for damaging materials or causing the materials to become friable. The USEPA defines asbestos-containing material as material containing greater than one percent asbestos. This review was not a pre-demolition/renovation survey or for regulatory submittal purposes.
Suspect and/or presumed ACMs were observed within the subject building during the property visit. These suspect and/or presumed ACMs that were not sampled as part of this asbestos survey are listed in the following table.
Sample Description Physical Condition
Friable Yes/No
Type of
ACM
Sample ID
Caulking, On Exterior Wall Joints UPS4 NoM
Wiring, Fibrous Electrical Cable Covering UPS6 NoM
Fire Doors, Fire Door Insulation UPS7 NoM
Mastic, Mirror Mastic UPS8 NoM
Caulking, Window Glazing UPS10 NoM
Duct Insulation, Duct Vibration Joint UPS11 NoM
Leveling Compound, Below ceramic tile flooring UPS13 NoM
Task Order GSE 013 Page 11 of 27
Building 4759, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama
8. Survey Sampling Results
The results of the Survey are presented in the tables on the following pages. The tables describe the entire suspect Asbestos-Containing Materials (ACMs) identified in the building and list respective sample numbers and laboratory results. Sample numbers presented in the tables correspond to the sample numbers on attached Laboratory Analysis Forms. Also presented in the tables is the estimated quantity and assessed friability for each suspect ACM. For each suspect material identified as ACM, the assessed hazard potential is presented along with GSE’ recommended response action. Hazard potential for each material application is based on the material condition and accessibility to the public and maintenance personnel.
Glossary of Items for the following Table
Type of Asbestos (1) CH = Chrysotile
AM = Amosite CR = Crocidolite AN = Anthophyllite TR = Tremolite AC = Actinolite ND = No Asbestos Detected PC = Point Count Method
Type of ACM (2) M = Miscellaneous S = Surfacing TSI = Thermal Systems Insulation
Friability (3) F = Friable NF = Non Friable
Physical Condition (4) U = Good D = Damaged SD = Significantly Damaged
Potential for Disturbance (5) NPD = No Potential for Disturbance PD = Potential for Disturbance PSD = Potential for Significant Disturbance
Assessment Category (6) 1 = Damaged or significantly damaged TSI ACBM, 2 = Damaged friable surfacing ACBM 3 = Significantly damaged friable surfacing ACBM 4 = Damaged or significantly damaged friable miscellaneous ACBM 5 = ACBM with potential for damaged 6 = ACBM potential for significant damage 7 = Any remaining friable ACBM or friable suspected
ACBM
X = not applicable
Unit of Measurement SF = Square Feet
LF = Linear Feet
Sample Location
Sample Analyzed
Yes/No
Estimated Quantity of
ACM
Assessment Category
Physical Condition
Friable Yes/No
Type of
ACM
% and Type of Asbestos Detected
Sample ID Potential For
Distrubance
Homogeneous Area 1
12" x 12" Floor Tile White with Gray Smudges
Yes M No U XRoom: 110 Grid: F1-4
ND - Floor Tile ND - Yellow Mastic ND - Black Mastic
1 PD
Yes M No U XRoom: 110 Grid: F4-1
ND - Floor Tile ND - Yellow Mastic ND - Black Mastic
2 PD
Yes M No U XRoom: 109 Grid: F1-2
ND - Floor Tile ND - Yellow Mastic ND - Black Mastic
3 PD
Homogeneous Area 2
Cove Base Black Cove Base and Mastic
Yes M No U XRoom: 110 Grid: WF4-4
ND - Cove Base ND - Cream Mastic
4 PD
Yes M No U XRoom: 109 Grid: WE1-4
ND - Cove Base ND - Cream Mastic
5 PD
Yes M No U XRoom: 108A Grid: WE1-2
ND - Cove Base ND - Cream Mastic
6 PD
Sample Location
Sample Analyzed
Yes/No
Estimated Quantity of
ACM
Assessment Category
Physical Condition
Friable Yes/No
Type of
ACM
% and Type of Asbestos Detected
Sample ID Potential For
Distrubance
Homogeneous Area 3
Pipe Insulation White Mastic on Pipe Insulation
Yes TSI No U XRoom: 200 Grid: F1-2
ND - Insulation ND - Paper/ Foil Wrap ND - White Mastic
7 PD
Yes TSI No U XRoom: 108B Grid: C1-4
ND - Insulation ND - Paper/ Foil Wrap ND - White Mastic
8 PD
Yes TSI No U XRoom: 101 Grid: WR1-4
ND - Insulation ND - Paper/ Foil Wrap ND - White Mastic
9 PD
Homogeneous Area 4
Pipe Insulation Gray Mastic on Pipe Insulation
Yes TSI No U XRoom: 101 Grid: WL2-2
ND - Insulation ND - Paper/ Foil Wrap ND - Gray Mastic
10 PD
Yes TSI No U XRoom: 101 Grid: WL2-2
ND - Insulation ND - Paper/ Foil Wrap ND - Gray Mastic
11 PD
Yes TSI No U XRoom: 101 Grid: WL2-2
ND - Insulation ND - Paper/ Foil Wrap ND - Gray Mastic
12 PD
Sample Location
Sample Analyzed
Yes/No
Estimated Quantity of
ACM
Assessment Category
Physical Condition
Friable Yes/No
Type of
ACM
% and Type of Asbestos Detected
Sample ID Potential For
Distrubance
Homogeneous Area 5
12" x 12" Floor Tile Olive With White Speckles
Yes M No U XRoom: 108B Grid: F2-4
ND - Floor Tile ND - Black Mastic
13 PD
Yes M No U XRoom: 108B Grid: F4-3
ND - Floor Tile ND - Black Mastic
14 PD
Yes M No U XRoom: 108B Grid: F4-3
ND - Floor Tile ND - Black Mastic
15 PD
Homogeneous Area 6
Pipe Insulation With Cotton Wrap
Yes 450 LF TSI Yes U 1Room: 200 Grid: F4-3
20% AM - Thermal Insulation 5% CH - Thermal Insulation ND - Cotton Wrap 10% CH - Mastic
16 PD
No TSI Yes U 1Room: 200 Grid: F1-1
Not Analyzed Positive Stop
17 PD
No TSI Yes D 1Room: 108A Grid: F4-4
Not Analyzed Positive Stop
18 PD
Sample Location
Sample Analyzed
Yes/No
Estimated Quantity of
ACM
Assessment Category
Physical Condition
Friable Yes/No
Type of
ACM
% and Type of Asbestos Detected
Sample ID Potential For
Distrubance
Homogeneous Area 7
Pipe Insulation Elbow and Fitting Insulation
Yes TSI Yes U 5Room: 200 Grid: F4-4
ND - Thermal Insulation
19 PD
No TSI Yes U 5Room: 108A Grid: F4-4
Not Analyzed Positive Stop
20 PD
Yes 100 Elbows TSI Yes U 5Room: 108A Grid: F4-4
3% CH - Thermal Insulation
21 PD
Homogeneous Area 8
Wallboard Drywall System
Yes M No U XRoom: 108B Grid: WE1-1
ND - Drywall Material ND - Paint/ Texture
22 PD
Yes M No U XRoom: 101 Grid: WR1-3
ND - Drywall Material ND - Texture
23 PD
Yes M No U XRoom: 102 Grid: WF2-4
ND - Drywall Material ND - Joint Compound
24 PD
Sample Location
Sample Analyzed
Yes/No
Estimated Quantity of
ACM
Assessment Category
Physical Condition
Friable Yes/No
Type of
ACM
% and Type of Asbestos Detected
Sample ID Potential For
Distrubance
Homogeneous Area 9
2' X 4' Ceiling Tile Fissures
Yes M Yes D XRoom: 103 Grid: C3-1
ND - Acoustic Tile25 PD
Yes M Yes D XRoom: 103 Grid: C3-2
ND - Acoustic Tile26 PD
Yes M Yes D XRoom: 103 Grid: C2-3
ND - Acoustic Tile27 PD
Homogeneous Area 10
Mastic Brown Mastic on Vacuum Lines
Yes M No U XRoom: 101 Grid: F4-1
ND - Brown Mastic28 PD
Yes M No U XRoom: 101 Grid: F4-3
ND - Brown Mastic29 PD
Yes M No U XRoom: 101 Grid: F3-4
ND - Brown Mastic30 PD
Sample Location
Sample Analyzed
Yes/No
Estimated Quantity of
ACM
Assessment Category
Physical Condition
Friable Yes/No
Type of
ACM
% and Type of Asbestos Detected
Sample ID Potential For
Distrubance
Homogeneous Area 11
Non Skid Floor Strips Black Floor Strips
Yes M No U XRoom: 101 Grid: F1-3
ND - Non Skid Strip ND - Yellow Mastic
31 PD
Yes M No U XRoom: 101 Grid: F4-1
ND - Non Skid Strip ND - Yellow Mastic
32 PD
Yes M No U XRoom: 101 Grid: F4-1
ND - Non Skid Strip ND - Yellow Mastic
33 PD
Homogeneous Area 12
Sink Undercoating Silver
Yes M No U XRoom: 102A Grid: F3-1
ND - Sink Undercoating
34 PD
Yes M No U XRoom: 102A Grid: F3-1
ND - Sink Undercoating
35 PD
Yes M No U XRoom: 102A Grid: F3-1
ND - Sink Undercoating
36 PD
1. CH = Chrysotile; AM = Amosite; CR = Crocidolite; AN = Anthophyllite; TR = Tremolite; AC = Actinolite; ND = No Asbestos Detected; or PC = Point Count Method
2. M = Miscellaneous; S = Surfacing; or TSI = Thermal Systems Insulation
3. F = Friable or NF = Non Friable
4. U = Good; D = Damaged; or SD = Significantly Damaged
5. NPD = No Potential for Disturbance; PD = Potential for Disturbance; or PSD = Potential for Significant Disturbance
6. 1 = Damaged or significantly damaged TSI ACBM, 2 = Damaged friable surfacing ACBM, 3 = Significantly damaged friable surfacing ACBM, 4 = Damaged or significantly damaged friable miscellaneous ACBM, 5 = ACBM with potential for damage, 6 = ACBM potential for significant damage, 7 = Any remaining friable ACBM or friable suspected ACBM, or X = not applicable
SF = Square Feet LF = Linear Feet
9. Appendices
Appendix A— Laboratory Results and Chain of Custody Appendix B— ACM Sample Location Drawings Appendix C— ACM Location Diagrams Appendix D— Photographs Appendix E— Certificates and Licenses
Appendix A
Laboratory Results
PLM Summary Report NVLAP Lab No. 102056
TDSHS License No. 30-0084
Client :
Project :
Project # :
Identification :
Test Method :
Great Southern Engineering
MSFC Building 4759
GSE-013
Asbestos, Bulk Sample Analysis
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 8/4/2008, thirty (30) bulk material samples were submitted by a representative of Great Southern Engineering for asbestos analysis by PLM/DS. The
PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Steve Moody Micro Services, LLC
Lab Job No. :
Report Date :
08B-09198
07/25-26/2008
08/04/2008
2051 Valley View Lane
Farmers Branch, TX 75234 (Phone 972-241-8460)
01 12" x 12" Floor Tile (White with Gray Smudges) and Mastic None Detected - Floor Tile
None Detected - Yellow Mastic
None Detected - Black Mastic
02 12" x 12" Floor Tile (White with Gray Smudges) and Mastic None Detected - Floor Tile
None Detected - Yellow Mastic
None Detected - Black Mastic
03 12" x 12" Floor Tile (White with Gray Smudges) and Mastic None Detected - Floor Tile
None Detected - Yellow Mastic
04 Cove Base (Black) and Mastic None Detected - Cove Base
None Detected - Cream Mastic
05 Cove Base (Black) and Mastic None Detected - Cove Base
None Detected - Cream Mastic
06 Cove Base (Black) and Mastic None Detected - Cove Base
None Detected - Cream Mastic
07 Mastic (White) with Pipe Insulation None Detected - Insulation
None Detected - Paper / Foil Wrap
None Detected - White Mastic
08 Mastic (White) with Pipe Insulation None Detected - Insulation
None Detected - Paper / Foil Wrap
None Detected - White Mastic
09 Mastic (White) with Pipe Insulation None Detected - Insulation
None Detected - Paper / Foil Wrap
None Detected - White Mastic
10 Mastic (Gray) with Pipe Insulation None Detected - Insulation
None Detected - Paper / Foil Wrap
None Detected - Grey Mastic
11 Mastic (Gray) with Pipe Insulation None Detected - Insulation
None Detected - Paper / Foil Wrap
None Detected - Grey Mastic
TDSHS License No. 30-0084
Client :
Project :
Project # :
Identification :
Test Method :
Great Southern Engineering
MSFC Building 4759
GSE-013
Asbestos, Bulk Sample Analysis
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 8/4/2008, thirty (30) bulk material samples were submitted by a representative of Great Southern Engineering for asbestos analysis by PLM/DS. The
PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Steve Moody Micro Services, LLC
Lab Job No. :
Report Date :
08B-09198
07/25-26/2008
08/04/2008
2051 Valley View Lane
Farmers Branch, TX 75234 (Phone 972-241-8460)
12 Mastic (Gray) with Pipe Insulation None Detected - Insulation
None Detected - Paper / Foil Wrap
None Detected - Grey Mastic
13 12" x 12" Floor Tile (Olive) and Mastic None Detected - Floor Tile
None Detected - Black Mastic
14 12" x 12" Floor Tile (Olive) and Mastic None Detected - Floor Tile
None Detected - Black Mastic
15 12" x 12" Floor Tile (Olive) and Mastic None Detected - Floor Tile
None Detected - Black Mastic
16 Pipe Insulation and Cover 20% Amosite - Thermal Insulation
5% Chrysotile - Thermal Insulation
None Detected - Cotton Wrap
10% Chrysotile - Mastic
17 Pipe Insulation and Cover Not Analyzed - Positive Stop
18 Pipe Insulation and Cover Not Analyzed - Positive Stop
19 Elbow and Fitting Insulation None Detected - Thermal Insulation
20 Elbow and Fitting Insulation Not Analyzed - No Sample
21 Elbow and Fitting Insulation 3% Chrysotile - Thermal Insulation
22 Wall System None Detected - Drywall Material
None Detected - Paint / Texture
23 Wall System None Detected - Drywall Material
None Detected - Texture
24 Wall System None Detected - Drywall Material
None Detected - Joint Compound
25 2' x 4' Ceiling Tile None Detected - Acoustic Tile
26 2' x 4' Ceiling Tile None Detected - Acoustic Tile
27 2' x 4' Ceiling Tile None Detected - Acoustic Tile
TDSHS License No. 30-0084
Client :
Project :
Project # :
Identification :
Test Method :
Great Southern Engineering
MSFC Building 4759
GSE-013
Asbestos, Bulk Sample Analysis
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 8/4/2008, thirty (30) bulk material samples were submitted by a representative of Great Southern Engineering for asbestos analysis by PLM/DS. The
PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Steve Moody Micro Services, LLC
Lab Job No. :
Report Date :
08B-09198
07/25-26/2008
08/04/2008
2051 Valley View Lane
Farmers Branch, TX 75234 (Phone 972-241-8460)
28 Mastic (Brown) on Vacuum Lines None Detected - Brown Mastic
29 Mastic (Brown) on Vacuum Lines None Detected - Brown Mastic
30 Mastic (Brown) on Vacuum Lines None Detected - Brown Mastic
Robert W. MiracleAnalyst(s):
Lab Director : Steve Moody Approved Signatory :
Thank you for choosing Steve Moody Micro Services
These samples were analyzed by layers. Quantification, unless otherwise noted, is performed by calibrated visual estimate. Results may not be reproduced except in full. This test report relates only to the samples tested. These test results do not imply endorsement by NVLAP or any agency of the U.S. Government. Accredited by the
National Voluntary Laboratory Accreditation Program for Bulk Asbestos Fiber Analysis under Lab Code 102056.
Lab Manager : Bruce Crabb Approved Signatory :
Steve Moody Micro Services, LLC PLM Detail Report NVLAP Lab No. 102056
TDSHS License No. 30-0084
Project # : GSE-013
Sample Number Layer Components % Of
Sample
Analysis
Date
% of
Layer Analyst
Supplement to PLM Summary Report 2051 Valley View Lane
Farmers Branch, TX 75234
Client :
Project :
Great Southern Engineering
MSFC Building 4759
Lab Job No. :
Report Date :
08B-09198
08/04/2008
Calcite / Vinyl Binders01 Floor Tile (White) 95% 08/04100% RM
Glue Binders01 Yellow Mastic (Yellow) 3% 08/04100% RM
Cellulose Fibers01 Black Mastic (Black) 2% 08/045% RM
Tar Binders01 Black Mastic (Black) 2% 08/0495% RM
Calcite / Vinyl Binders02 Floor Tile (White) 98% 08/04100% RM
Glue Binders02 Yellow Mastic (Yellow) 2% 08/04100% RM
Cellulose Fibers02 Black Mastic (Black) <1% 08/045% RM
Tar Binders02 Black Mastic (Black) <1% 08/0495% RM
Calcite / Vinyl Binders03 Floor Tile (White) 98% 08/04100% RM
Glue Binders03 Yellow Mastic (Yellow) 2% 08/04100% RM
Calcite / Vinyl Binders04 Cove Base (Black) 40% 08/04100% RM
Calcite04 Cream Mastic (Cream) 60% 08/0450% RM
Glue Binders04 Cream Mastic (Cream) 60% 08/0450% RM
Calcite / Vinyl Binders05 Cove Base (Black) 85% 08/04100% RM
Calcite05 Cream Mastic (Cream) 15% 08/0450% RM
Glue Binders05 Cream Mastic (Cream) 15% 08/0450% RM
Calcite / Vinyl Binders06 Cove Base (Black) 90% 08/04100% RM
Calcite06 Cream Mastic (Cream) 10% 08/0450% RM
Glue Binders06 Cream Mastic (Cream) 10% 08/0450% RM
Mineral Wool Fibers07 Insulation (Yellow) 40% 08/0495% RM
Resin Binders07 Insulation (Yellow) 40% 08/045% RM
Cellulose Fibers07 Paper / Foil Wrap (Tan / Silver) 25% 08/0460% RM
Glass Wool Fibers07 Paper / Foil Wrap (Tan / Silver) 25% 08/0420% RM
Metal Foil07 Paper / Foil Wrap (Tan / Silver) 25% 08/0420% RM
Cellulose Fibers07 White Mastic (White) 35% 08/045% RM
Pigment / Binders07 White Mastic (White) 35% 08/0495% RM
Project # : GSE-013
Sample Number Layer Components % Of
Sample
Analysis
Date
% of
Layer Analyst
Supplement to PLM Summary Report 2051 Valley View Lane
Farmers Branch, TX 75234
Client :
Project :
Great Southern Engineering
MSFC Building 4759
Lab Job No. :
Report Date :
08B-09198
08/04/2008
Mineral Wool Fibers08 Insulation (Yellow) 20% 08/0495% RM
Resin Binders08 Insulation (Yellow) 20% 08/045% RM
Cellulose Fibers08 Paper / Foil Wrap (Tan / Silver) 25% 08/0460% RM
Glass Wool Fibers08 Paper / Foil Wrap (Tan / Silver) 25% 08/0420% RM
Metal Foil08 Paper / Foil Wrap (Tan / Silver) 25% 08/0420% RM
Cellulose Fibers08 White Mastic (White) 55% 08/045% RM
Pigment / Binders08 White Mastic (White) 55% 08/0495% RM
Mineral Wool Fibers09 Insulation (Yellow) 40% 08/0495% RM
Resin Binders09 Insulation (Yellow) 40% 08/045% RM
Cellulose Fibers09 Paper / Foil Wrap (Tan / Silver) 25% 08/0460% RM
Glass Wool Fibers09 Paper / Foil Wrap (Tan / Silver) 25% 08/0420% RM
Metal Foil09 Paper / Foil Wrap (Tan / Silver) 25% 08/0420% RM
Cellulose Fibers09 White Mastic (White) 35% 08/045% RM
Pigment / Binders09 White Mastic (White) 35% 08/0495% RM
Mineral Wool Fibers10 Insulation (Yellow) 50% 08/0495% RM
Resin Binders10 Insulation (Yellow) 50% 08/045% RM
Cellulose Fibers10 Paper / Foil Wrap (Tan / Silver) 25% 08/0460% RM
Glass Wool Fibers10 Paper / Foil Wrap (Tan / Silver) 25% 08/0420% RM
Metal Foil10 Paper / Foil Wrap (Tan / Silver) 25% 08/0420% RM
Cellulose Fibers10 Grey Mastic (Grey) 25% 08/045% RM
Pigment / Binders10 Grey Mastic (Grey) 25% 08/0495% RM
Mineral Wool Fibers11 Insulation (Yellow) 50% 08/0495% RM
Resin Binders11 Insulation (Yellow) 50% 08/045% RM
Cellulose Fibers11 Paper / Foil Wrap (Tan / Silver) 25% 08/0460% RM
Glass Wool Fibers11 Paper / Foil Wrap (Tan / Silver) 25% 08/0420% RM
Metal Foil11 Paper / Foil Wrap (Tan / Silver) 25% 08/0420% RM
Cellulose Fibers11 Grey Mastic (Grey) 25% 08/045% RM
Pigment / Binders11 Grey Mastic (Grey) 25% 08/0495% RM
Project # : GSE-013
Sample Number Layer Components % Of
Sample
Analysis
Date
% of
Layer Analyst
Supplement to PLM Summary Report 2051 Valley View Lane
Farmers Branch, TX 75234
Client :
Project :
Great Southern Engineering
MSFC Building 4759
Lab Job No. :
Report Date :
08B-09198
08/04/2008
Mineral Wool Fibers12 Insulation (Yellow) 50% 08/0495% RM
Resin Binders12 Insulation (Yellow) 50% 08/045% RM
Cellulose Fibers12 Paper / Foil Wrap (Tan / Silver) 25% 08/0460% RM
Glass Wool Fibers12 Paper / Foil Wrap (Tan / Silver) 25% 08/0420% RM
Metal Foil12 Paper / Foil Wrap (Tan / Silver) 25% 08/0420% RM
Cellulose Fibers12 Grey Mastic (Grey) 25% 08/045% RM
Pigment / Binders12 Grey Mastic (Grey) 25% 08/0495% RM
Calcite / Vinyl Binders13 Floor Tile (Light Tan) 98% 08/04100% RM
Tar Binders13 Black Mastic (Black) 2% 08/04100% RM
Calcite / Vinyl Binders14 Floor Tile (Light Tan) 98% 08/04100% RM
Tar Binders14 Black Mastic (Black) 2% 08/04100% RM
Calcite / Vinyl Binders15 Floor Tile (Light Tan) 98% 08/04100% RM
Tar Binders15 Black Mastic (Black) 2% 08/04100% RM
Amosite16 Thermal Insulation (White) 85% 08/0420% RM
Chrysotile16 Thermal Insulation (White) 85% 08/045% RM
Binders / Fillers16 Thermal Insulation (White) 85% 08/0475% RM
Cotton Fibers16 Cotton Wrap (Off-White) 5% 08/04100% RM
Chrysotile16 Mastic (Light Grey) 10% 08/0410% RM
Pigment / Binders16 Mastic (Light Grey) 10% 08/0490% RM
17 Not Analyzed - Positive Stop 100% 08/04 RM
18 Not Analyzed - Positive Stop 100% 08/04 RM
Mineral Wool Fibers19 Thermal Insulation (Light Grey) 100% 08/0420% RM
Binders / Fillers19 Thermal Insulation (Light Grey) 100% 08/0480% RM
20 Not Analyzed - No Sample 100% 08/04 RM
Chrysotile21 Thermal Insulation (Light Grey) 100% 08/043% RM
Mineral Wool Fibers21 Thermal Insulation (Light Grey) 100% 08/0420% RM
Binders / Fillers21 Thermal Insulation (Light Grey) 100% 08/0477% RM
Project # : GSE-013
Sample Number Layer Components % Of
Sample
Analysis
Date
% of
Layer Analyst
Supplement to PLM Summary Report 2051 Valley View Lane
Farmers Branch, TX 75234
Client :
Project :
Great Southern Engineering
MSFC Building 4759
Lab Job No. :
Report Date :
08B-09198
08/04/2008
Cellulose Fibers22 Drywall Material (White) 85% 08/045% RM
Gypsum / Binders22 Drywall Material (White) 85% 08/0495% RM
Cellulose Fibers22 DW Paper Facing (Tan) 10% 08/04100% RM
Calcite22 Paint / Texture (White) 5% 08/0425% RM
Pigment / Binders22 Paint / Texture (White) 5% 08/0475% RM
Cellulose Fibers23 Drywall Material (White) 80% 08/045% RM
Gypsum / Binders23 Drywall Material (White) 80% 08/0495% RM
Cellulose Fibers23 DW Paper Facing (Tan) 10% 08/04100% RM
Calcite / Talc / Binders23 Texture (White) 10% 08/04100% RM
Cellulose Fibers24 Drywall Material (White) 80% 08/045% RM
Gypsum / Binders24 Drywall Material (White) 80% 08/0495% RM
Cellulose Fibers24 DW Paper / Tape (Tan / White) 10% 08/04100% RM
Calcite / Talc / Binders24 Joint Compound (White) 10% 08/04100% RM
Cellulose Fibers25 Acoustic Tile (Light Grey) 100% 08/0450% RM
Mineral Wool Fibers25 Acoustic Tile (Light Grey) 100% 08/0430% RM
Perlite25 Acoustic Tile (Light Grey) 100% 08/0420% RM
Cellulose Fibers26 Acoustic Tile (Light Grey) 100% 08/0450% RM
Mineral Wool Fibers26 Acoustic Tile (Light Grey) 100% 08/0430% RM
Perlite26 Acoustic Tile (Light Grey) 100% 08/0420% RM
Cellulose Fibers27 Acoustic Tile (Light Grey) 100% 08/0450% RM
Mineral Wool Fibers27 Acoustic Tile (Light Grey) 100% 08/0430% RM
Perlite27 Acoustic Tile (Light Grey) 100% 08/0420% RM
Glue Binders28 Brown Mastic (Brown) 100% 08/04100% RM
Glue Binders29 Brown Mastic (Brown) 100% 08/04100% RM
Glue Binders30 Brown Mastic (Brown) 100% 08/04100% RM
TDSHS License No. 30-0084
Client :
Project :
Project # :
Identification :
Test Method :
Great Southern Engineering
MSFC, Building 4759
GSE-013
Asbestos, Bulk Sample Analysis
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 10/6/2008, six (6) bulk material samples were submitted by a representative of Great Southern Engineering for asbestos analysis by PLM/DS. The
PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Steve Moody Micro Services, LLC
Lab Job No. :
Report Date :
08B-11505
09/30/2008
10/07/2008
2051 Valley View Lane
Farmers Branch, TX 75234 (Phone 972-241-8460)
31 Non-skid Floor Strips None Detected - Non-Skid Strip
None Detected - Yellow Mastic
32 Non-skid Floor Strips None Detected - Non-Skid Strip
None Detected - Yellow Mastic
33 Non-skid Floor Strips None Detected - Non-Skid Strip
None Detected - Yellow Mastic
34 Sink Undercoating None Detected - Sink Undercoating
35 Sink Undercoating None Detected - Sink Undercoating
36 Sink Undercoating None Detected - Sink Undercoating
Brian R. SchmidtAnalyst(s):
Lab Director : Steve Moody Approved Signatory :
Thank you for choosing Steve Moody Micro Services
These samples were analyzed by layers. Quantification, unless otherwise noted, is performed by calibrated visual estimate. Results may not be reproduced except in full. This test report relates only to the samples tested. These test results do not imply endorsement by NVLAP or any agency of the U.S. Government. Accredited by the
National Voluntary Laboratory Accreditation Program for Bulk Asbestos Fiber Analysis under Lab Code 102056.
Lab Manager : Bruce Crabb Approved Signatory :
Project # : GSE-013
Sample Number Layer Components % Of
Sample
Analysis
Date
% of
Layer Analyst
Supplement to PLM Summary Report 2051 Valley View Lane
Farmers Branch, TX 75234
Client :
Project :
Great Southern Engineering
MSFC, Building 4759
Lab Job No. :
Report Date :
08B-11505
10/07/2008
Cotton Fibers31 Non-Skid Strip (Black) 97% 10/0760% BS
Aggregate31 Non-Skid Strip (Black) 97% 10/0720% BS
Binders / Fillers31 Non-Skid Strip (Black) 97% 10/0720% BS
Glue Binders31 Yellow Mastic (Yellow) 3% 10/07100% BS
Cotton Fibers32 Non-Skid Strip (Black) 98% 10/0760% BS
Aggregate32 Non-Skid Strip (Black) 98% 10/0720% BS
Binders / Fillers32 Non-Skid Strip (Black) 98% 10/0720% BS
Glue Binders32 Yellow Mastic (Yellow) 2% 10/07100% BS
Cotton Fibers33 Non-Skid Strip (Black) 98% 10/0760% BS
Aggregate33 Non-Skid Strip (Black) 98% 10/0720% BS
Binders / Fillers33 Non-Skid Strip (Black) 98% 10/0720% BS
Glue Binders33 Yellow Mastic (Yellow) 2% 10/07100% BS
Tar Binders34 Sink Undercoating (Black) 100% 10/07100% BS
Tar Binders35 Sink Undercoating (Black) 100% 10/07100% BS
Tar Binders36 Sink Undercoating (Black) 100% 10/07100% BS
Appendix B
ACM Sample Location Drawings
First Floor Building 4759
Marshall Space Flight Center Marshall Space Flight Center, AL
Task Order #GSE-013
14322813521112102824
26 27 30
18, 20, 6 14, First Floor
Marshall Space Flight Center Marshall Space Flight Center, AL
Task Order #GSE-013
33 32
34, 35, Mezzanine Floor
Marshall Space Flight Center Marshall Space Flight Center, AL
Task Order #GSE-013
Room
Appendix C
ACM Location Diagrams
Manju Ramasamudra Rectangle
Manju Ramasamudra Polygon
Manju Ramasamudra Text Box Pipe and Elbow Insulation
Appendix D
Photographs
Building 4759, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama
PHOTO 1. 12” X 12” white floor tile with gray smudges PHOTO 2. Black Cove base
PHOTO 3. Pipe insulation with white mastic PHOTO 4. Pipe insulation with gray mastic
PHOTO 5. 12” X 12” olive floor tile PHOTO 6. Pipe insulation with cover
Building 4759, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama
PHOTO 7. Pipe Elbow insulation PHOTO 8. Drywall system
PHOTO 9. 2’ X 4’ ceiling Tile PHOTO 10. Brown mastic on vacuum lines
Appendix E
License and Certifications
| 1. Introduction |
| 2. Summary |
| 2.1. Suspect ACMs |
| 2.2. Recommendations |
| 3. Survey Scope |
| 4. Limitations |
| 5. Survey and Sample Collection Procedure |
| 6. Previous Survey / Plans Review |
| 7. Suspect ACM Materials Not Sampled |
| 8. Survey Sampling Results |
| 9. Appendices |
| Appendix A Laboratory Results |
| Appendix B ACM Sample Location Drawings |
| Appendix C ACM Location Diagrams |
| Appendix D Photographs |
| Appendix E License and Certifications |