General Asbestos Survey for Asbestos-Containing Materials
Prepared for:
Marshall Space Flight Center, AL
Building 4650 Marshall Space Flight Center
GSE - 013
October 31, 2008
Prepared by
Great Southern Engineering, Inc.
3795 Gordon Terry Parkway
Trinity, Alabama 35673
TABLE OF CONTENTS
1. Introduction
2. Summary
2.1. Suspect ACMs
2.2. Recommendations
3. Survey Scope
4. Limitations
5. Survey and Sample Collection Procedure
6. Previous Survey / Plans Review
7. Suspect ACM Materials Not Sampled
8. Survey Sampling Results
9. Appendices
Task Order GSE 013 Page 1 of 29
GENERAL ASBESTOS SURVEY OF
Building 4650, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama
1. Introduction
In accordance with GSE Task Order No.GSE-013 dated April 21, 2008, Great Southern Engineering, Inc. (GSE) has performed an asbestos survey of Building 4650 located at George C.
Marshall Space Flight Center, Marshall Space Flight Center, Alabama. The 109,155 square feet building was identified to have been originally constructed in 1958. A total of 108 samples were collected from the building.
The objective of the Asbestos Survey is to determine the location and quantity of asbestos-containing materials at the Property building.
GSE’s Scope of Work included:
Visual inspection and identification of suspect asbestos-containing materials (ACMs) in the Property building and collected a representative number of samples for analysis.
As part of this asbestos survey, GSE personnel collected samples of all suspect friable and suspect damaged non-friable building materials at the Property. The remaining suspect non-friable materials were not be sampled as part of this asbestos survey
Estimated quantities and locations of ACM.
Assessed the condition of the ACM identified.
Assigned a hazard rating to each type of ACM.
This report has been prepared for the use of George C. Marshall Space Flight Center. Our investigation was performed using the degree of care and skill ordinarily exercised under similar circumstances by professional consultants practicing in this or similar localities. No other warranty or guarantee, expressed or implied, is made as to the conclusions included in this report.
Task Order GSE 013 Page 2 of 29
Building 4650, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama
The GSE, Inc. did not perform destructive sampling procedures at the site; therefore, regardless of the thoroughness of this survey, it is possible that suspected asbestos-containing materials (ACMs) might exist in the building beneath the floors, behind walls, within pipe chases, or in other inaccessible locations. If, during renovation or demolition activities, materials not addressed in this survey are discovered, these materials should be sampled and analyzed for asbestos content prior to disturbance.
Surveyed by:
William F. Ystueta
University of Alabama Safe State Program Accredited Inspector
Accreditation #AIN0508Y6144
Jeff R Smith
University of Alabama Safe State Program Accredited Inspector/Management Planner
Accreditation #APL0408S7033
Written by:
Manju Ramasamudra
University of Alabama Safe State Program Accredited Inspector/Management Planner
Accreditation #APL0308R5089
Task Order GSE 013 Page 3 of 29
Building 4650, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama
2. Summary
GSE performed an Asbestos Survey and Hazard Assessment at Building 4650 in Marshall Space Flight Center, Alabama on July 28, September 4, and October 24, 2008. Sample collection was completed by licensed personnel – William F. Ystueta and Jeff R Smith. The following report summarizes the independent conclusions representing GSE’ best professional judgment based on information and data available to us during the course of this survey. Factual information regarding operations, conditions, and tests data provided by the client, owner or their representative has been assumed to be correct and complete. Additionally, the conclusions presented are based on the conditions that existed on the date(s) of the assessment.
The 109,155 square feet building was identified to have been originally constructed in 1958. A total of 108 samples were collected from the building. Eight (8) Homogeneous materials were identified as asbestos-containing materials. A summary of the samples collected for this area and corresponding analytical results is presented below.
Sample Description
Sample
ID
Building Number
Sample Material
ACM
Quantity
4650 106 Pipe Insulation White Cloth Coverings 900 LF
Room Number Grid Numbers 16 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4, WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3, WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
19N C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4, WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3, WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
25A C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4, WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3, WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
Sample Description
Sample
ID
Building Number
Sample Material
ACM
Quantity
4650 112 Miscellaneous Debris Above Ceiling Tiles 769 SF
Room Number Grid Numbers 27 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4
Sample Description
Sample
ID
Building Number
Sample Material
ACM
Quantity
4650 127 9" x 9" Floor Tile Green Floor Tile 1,690 SF
Room Number Grid Numbers 25 F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4
26 F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4
Sample Description
Sample
ID
Building Number
Sample Material
ACM
Quantity
4650 130 HVAC Duct Insulation Duct Insulation with Canvas Cover 200 LF
Room Number Grid Numbers 16 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4
Sample Description
Sample
ID
Building Number
Sample Material
ACM
Quantity
4650 133 HVAC Duct Insulation Duct Insulation with Black Mastic 200 LF
Room Number Grid Numbers 19N C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4
Sample
ID
Building Number
Sample Material
ACM
Quantity
4650 22 Pipe Insulation Elbow and Fitting Insulation 200 Elbows
Room Number Grid Numbers 104A WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3, WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
106 WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3,
WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
108 WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3,
WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
10A WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3,
WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
10B WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3,
WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
10C C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4, WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3, WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
110 WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3,
WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
111 WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3,
WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
133 WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3,
WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
16 WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3,
WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
19N WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3,
WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
201 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4, WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3, WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
202 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4, WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3, WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
203 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4, WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3, WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
204 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4, WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3, WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
205 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4, WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3, WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
208 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4, WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3, WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
209 C1-1, C1-2, C1-3, C1-4, C2-1, C2-2, C2-3, C2-4, C3-1, C3-2, C3-3, C3-4, C4-1, C4-2, C4-3, C4-4, WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3, WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
25A WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3,
WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
Sample
ID
Building Number
Sample Material
ACM
Quantity
4650 22 Pipe Insulation Elbow and Fitting Insulation 200 Elbows
Room Number Grid Numbers
27 WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3,
WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
30 WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3,
WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
30A WF1-1, WF1-2, WF1-3, WF1-4, WF2-1, WF2-2, WF2-3, WF2-4, WF3-1, WF3-2, WF3-3,
WF3-4, WF4-1, WF4-2, WF4-3, WF4-4
Sample Description
Sample
ID
Building Number
Sample Material
ACM
Quantity
4650 46 9" x 9" Floor Tile Green Floor Tile 1,752 SF
Room Number Grid Numbers 102 F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4
104A F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4
105 F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4
110 F1-1, F1-2, F1-3, F1-4, F2-1, F2-2, F2-3, F2-4, F3-1, F3-2, F3-3, F3-4, F4-1, F4-2, F4-3, F4-4
Sample Description
Sample
ID
Building Number
Sample Material
ACM
Quantity
4650 55 Sink Undercoating Black Cove Base Mastic 10 SF
Room Number Grid Numbers 110 F4-2
WL1-1
WR2-1
WR1-1
WL3-1
WL2-1
WR4-1
WR3-1
F1-1 F2-1 F3-1 F4-1
C1-1 C2-1 C3-1 C4-1
C1-2
C1-3
C1-4
C2-2
C2-3
C2-4
C3-2
C3-3
C3-4
C4-2
C4-3
C4-4
WR4-2
WR4-3
WR4-4
WR3-2
WR3-3
WR3-4
WR2-2
WR2-3
WR2-4
WR1-2
WR1-3
WR1-4
F4-2
F4-3
F4-4
F3-2
F3-4
F2-2
F2-3
F2-4
F1-2
F1-3
F1-4
WL1-2
WL1-3
WL1-4
WL2-2
WL2-3
WL2-4
WL3-2
WL3-3
WL3-4
WL4-2
WL4-3
WL4-4
F3-3
WL4-1
WF4-1 WF4-2 WF4-3 WF4-4
WF3-1
WF2-1
WF1-1
WF3-2
WF2-2
WF1-2
WF3-3
WF2-3
WF1-3
WF3-4
WF2-4
WF1-4
WE4-1WE4-2WE4-3WE4-4
WE3-1
WE2-1
WE1-1
WE3-2
WE2-2
WE1-2
WE3-3
WE2-3
WE1-3
WE3-4
WE2-4
WE1-4
Map Document: (G:\asbestos\Asbestos_Room_grid.mxd)
1. Note: Entry wall depicted is as seen from inside the room, therefore grid WE4-4 is located at the top left corner of wall. The main entry door is located within the entry wall.
2. Entry wall location shall be described as N (North) S (South) E (East) or W (West) as seen from the inside of the room. Utilizing the facilities data book, N is located at the top of page, S at bottom of page, E at right of page and W and left of page regardless of bearing shown on drawing for all buildings. (The directional bearing symbol is pointing to either NE or NW for approximately 29 buildings in the facilities data book. Consider these NE or NW bearings as being Plan N when identifying the direction of the entry wall.)
The only exception is building 4705, this drawing shall be oriented towards North as shown on drawing.
3. Type of grid system uses 4 grids by length and 4 grids by width irrespective of the room size.
Grid: C - ceiling, WF - far wall, WE - entry wall, WL - left wall, WR - right wall, F - floor
Asbestos Survey Room Grid Note: Asbestos containing material above the ceiling should be noted on the ceiling grid
Far Wall Entry Wall
Far Wall
WL1-1
WR2-1
WR1-1
WL3-1
WL2-1
WR4-1
WR3-1
WR4-2
WR4-3
WR4-4
WR3-2
WR3-3
WR3-4
WR2-2
WR2-3
WR2-4
WR1-2
WR1-3
WR1-4
WL1-2
WL1-3
WL1-4
WL2-2
WL2-3
WL2-4
WL3-2
WL3-3
WL3-4
WL4-2
WL4-3
WL4-4
WL4-1
C1-1 C2-1 C3-1 C4-1
C1-2
C1-3
C1-4
C2-2
C2-3
C2-4
C3-2
C3-3
C3-4
C4-2
C4-3
C4-4
WF4-1 WF4-2 WF4-3 WF4-4
WF3-1
WF2-1
WF1-1
WF3-2
WF2-2
WF1-2
WF3-3
WF2-3
WF1-3
WF3-4
WF2-4
WF1-4
WE4-1WE4-2WE4-3WE4-4
WE3-1
WE2-1
WE1-1
WE3-2
WE2-2
WE1-2
WE3-3
WE2-3
WE1-3
WE3-4
WE2-4
WE1-4
F1-1 F2-1 F3-1 F4-1
F4-2
F4-3
F4-4
F3-2
F3-4
F2-2
F2-3
F2-4
F1-2
F1-3
F1-4
F3-3
Map Document: (G:\asbestos\Asbestos_Hall_grid.mxd)
1. Note: Entry wall and far wall are optional; there maybe neither that are identified in the hallway. Entry wall depicted is as seen from inside the room, therefore grid WE4-1 is located at the top left corner of wall.
2. Type of grid system uses 4 grids by length and 4 grids by width irrespective of the hall size.
3. The identification of hallway segments will be determined by the end rooms. Hallways will be measured from South to North and from East to West Ex. Room most south of hallway is Room 107 and room most North of hallway is Room 200. Using H as the designation of hallway. The identification of hallway is HS107N200. Likewise from east to west would be HE107W200. The room number sequencing is arbitrary; Ex. HE200W107 would be acceptable. NS&EW are used to distinguish between vertical and horizontal run corridors on drawings.
4. Utilizing the facilities data book, N is located at the top of page, S at bottom of page, E at right of page and W and left of page regardless of bearing shown on drawing for all buildings. (The directional bearing symbol is pointing to either NE or NW for approximately 29 buildings in the facilities data book. Consider these NE or NW bearings as being Plan N when identifying the hallway number.) The only exception is building 4705, this drawing shall be oriented towards North as shown on drawing.
Grid: C - ceiling, WF - far wall, WE - entry wall, WL - left wall, WR - right wall, F - floor
Asbestos Survey Hallway Grid Note: Asbestos containing material above the ceiling should be noted on the ceiling grid
Far Wall Entry Wall
Far Wall Room XXXBeginning
Room YYY N or W
S or E
Task Order GSE 013 Page 4 of 29
Building 4650, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama
2.1. Suspect ACMs
The following information is included for informational purposes:
A. The following suspect asbestos-containing materials were not sampled as part of this scope of work:
Suspect fibrous electrical cable covering (danger of electrocution) were not sampled.
These materials are not subject to regulation under NESHAP for demolition and renovation as long as they are in good condition and are not subject to sanding, grinding, cutting, or abrading.
Since ordinary demolition activities do not include sanding, grinding, cutting, and abrading, these materials may remain in place during building demolition, as long as they remain in good condition and are not friable.
If the material is in poor condition and is friable at the time of demolition or renovation, or if it will be subjected to sanding, grinding, cutting, or abrading, it should first be removed by a licensed asbestos removal contractor and disposed of as asbestos-containing waste.
When removing asphalt-roofing products, the material should be removed using a method that does not subject the material to sanding, cutting, grinding, or abrading (hand tools).
Asbestos-containing roofing may be disposed of as construction debris.
Task Order GSE 013 Page 5 of 29
Building 4650, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama
2.2. Recommendations
The following additional actions are recommended:
The identified asbestos-containing 9” X 9” green floortile and associated black mastic, hard elbow and fitting insulations, pipe insulation with cloth wrap and gray insulation, sink undercoating, duct insulation with cloth cover, and black mastic associated with HVAC duct insulation are in good condition. In addition the identified asbestos containing miscellaneous debris observed above Room 27 ceiling was observed to be in significantly damaged condition. MSFC (Property owner/Operator) should develop and implement an Operations and Maintenance (O&M) Program. In addition suspect asbestos-containing materials in the form of caulking on exterior walls, grout on exterior block walls, electrical cable covering, fire doors, window caulking, mirror mastic, leveling compound below ceramic tile flooring, and duct vibration joints were not sampled as a part of this assessment. These materials can be maintained as part of the asbestos O&M Program. A properly designed O&M Program is sufficient to maintain the Project in accordance with current regulatory standards and sound business practice.
ACM maintained with an O&M Program can remain in place, provided the ACM and suspect ACM remain intact and undisturbed.
In addition, the debris observed above the ceiling was mainly debris material from the damaged pipe insulation materials. Hence, any building material located above the ceiling tiles should be considered as ACMs.
Task Order GSE 013 Page 6 of 29
Building 4650, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama
3. Survey Scope
This survey was conducted for the purpose of identifying asbestos-containing materials (ACM) throughout the building and to conduct a hazard assessment on existing ACM. The survey was non-destructive in nature and limited only to those areas that were readily accessible.
Specific areas to which access was limited by occupant request, unavailability of keys, or by site conditions included the following:
Behind the walls
Beneath the floors
Any suspect ACM not sampled as part of the assessment and if any additional suspect materials were to be identified behind walls and beneath the floors should be sampled prior to repair, renovation, or demolition activities.
Task Order GSE 013 Page 7 of 29
Building 4650, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama
4. Limitations
GSE did not attempt to disassemble mechanical equipment, open pipe chases or assess materials within wall voids. Regardless of the thoroughness of a survey, the possibility exists that some areas containing asbestos were not identified, inaccessible or different from those at specific locations. The findings and opinions presented are relative to the dates of our site work and should not be relied upon to represent conditions at substantially later dates due to changes in the condition ACM may change over time, renovations and repairs.
This report is for the exclusive use of the client and its agents and use by any unauthorized parties in whole or in part, except as directed by legal jurisdiction, is at the sole risk of the user.
If this assessment includes reliance on work products and/or documents prepared by others, GSE has no responsibility for the accuracy of information contained therein.
Although this assessment has attempted to identify the presence or absence of ACM, potential sources of ACM may have escaped detection due to: (1) the scope of this assessment, (2) the inaccuracy of records, interviews, work products or documents made available to GSE for this report, (3) the presence of undetected or unreported renovations and repairs, (4) inaccessible areas, and/or (5) deliberate concealment of detrimental information.
Estimates presented in this report are based upon observations during the survey and owner-provided information. These reasonable estimates may be affected by unanticipated conditions potentially present in inaccessible or un-surveyed areas. GSE does not warrant or guarantee the quantity estimates. The use of such estimates shall be at the user's own risk and shall constitute a release and agreement to defend and indemnify GSE from and against any liability. If questions arise during the planning for renovation, demolition, or other construction activities, GSE should be notified to permit review of the data and present recommendations.
Interior of the following rooms were inaccessible during our Asbestos Survey on July 28, September 4, and October 24, 2008: None.
Task Order GSE 013 Page 8 of 29
Building 4650, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama
5. Survey and Sample Collection Procedure
Based on United States Environmental Protection Agency (USEPA) guidance documents, GSE considered all material applications identified during the visual assessment were suspect ACM and sampled as described below.
Bulk samples were collected of any materials, which were suspected of containing asbestos with the exception of fire doors. Fire doors were not sampled because the damage caused by sampling would render these materials friable and may also void the fire rating. Since these materials were not sampled, they should be assumed to be asbestos containing, unless sampled and proven otherwise. Sampling of these assumed ACMs should be performed prior to any renovation or other activity that may cause a material disturbance.
Samples of the remaining suspect ACM were taken in accordance with USEPA recommendations.
The number and location of samples collected was based on the type of material, the manner of application, and the homogeneity of the ACM (similarity of color, texture, and type). Each sample was collected and placed into an individual sample container. The sample location was noted on the field survey form and assigned an individual identification number. This number was affixed to the sample container as the sample was collected. The survey form was also used to note the material type and general condition of the material. During the inspection, each suspect material's accessibility, location, and friability were recorded. This information was used to assess the potential hazard of the ACM and to prioritize response action recommendations.
The USEPA defines asbestos-containing materials (ACM) as those that contain greater than one percent asbestos. Friable materials are defined as those that can be crumbled or reduced to powder by hand pressure.
GSE utilized the “positive-stop” method of sample analysis. In this method, analysis is stopped on a group of samples once the first positive (e.g., greater than 1% asbestos) sample is analyzed.
According to the USEPA, if one sample of a homogenous material is identified to be asbestos containing, the entire material must be considered asbestos containing. By using the positive-stop method, GSE reduces the Client’s laboratory analysis cost by not analyzing the additional samples.
Samples collected were carried and submitted under Chain-of-Custody to Steve Moody Micro Services LLC, Farmers Branch, Texas for analysis of asbestos using USEPA Method 40 CFR, Chapter 1, Part 763, Subpart F, Appendix A, also known as Polarized Light Microscopy (PLM).
Steve Moody Micro Services LLC is certified by the National Voluntary Laboratory Accreditation Program (NVLAP) and licensed by the Department of State Health Services.
Task Order GSE 013 Page 9 of 29
Building 4650, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama
6. Previous Survey / Plans Review
GSE was not provided with any previously conducted asbestos surveys of the Property. As-built/renovation-site plans and construction drawings were reviewed at the Facilities Department Drawing Room. Review of these documents did not identify building material specifications requiring the use of ACM. However, this does not preclude or prevent the potential use of ACM.
Task Order GSE 013 Page 10 of 29
Building 4650, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama
7. Suspect ACM Materials Not Sampled
During the course of the property visit, GSE performed a preliminary review of interior, accessible areas of the subject building for the presence of suspect asbestos-containing materials (ACMs). This asbestos survey was conducted for overview purposes only; additional suspect materials may exist in concealed locations (behind walls and above ceilings, beneath the floors, within machinery, etc.). Also, not all suspect materials may have been sampled due to the condition or the location of the suspect materials. Destructive sampling of suspect ACMs was not performed. GSE will not be responsible for damaging materials or causing the materials to become friable. The USEPA defines asbestos-containing material as material containing greater than one percent asbestos. This review was not a pre-demolition/renovation survey or for regulatory submittal purposes.
Suspect and/or presumed ACMs were observed within the subject building during the property visit. These suspect and/or presumed ACMs that were not sampled as part of this asbestos survey are listed in the following table.
Sample Description Physical Condition
Friable Yes/No
Type of
ACM
Sample ID
9" X 9" Floor Tile, Located Below Carpet UPS2 NoM
12" X 12" Floor Tile, Located Below Carpet UPS3 NoM
Caulking, On Exterior Wall Joints UPS4 NoM
Grout, On Exterior Wall Masonary UPS5 NoM
Wiring, Fibrous Electrical Cable Covering UPS6 NoM
Fire Doors, Fire Door Insulation UPS7 NoM
Mastic, Mirror Mastic UPS8 NoM
Caulking, Window Glazing UPS10 NoM
Duct Insulation, Duct Vibration Joint UPS11 NoM
Transite, Panels UPS12 NoM
Leveling Compound, Below ceramic tile flooring UPS13 NoM
Task Order GSE 013 Page 11 of 29
Building 4650, George C. Marshall Space Flight Center, Marshall Space Flight Center, Alabama
8. Survey Sampling Results
The results of the Survey are presented in the tables on the following pages. The tables describe the entire suspect Asbestos-Containing Materials (ACMs) identified in the building and list respective sample numbers and laboratory results. Sample numbers presented in the tables correspond to the sample numbers on attached Laboratory Analysis Forms. Also presented in the tables is the estimated quantity and assessed friability for each suspect ACM. For each suspect material identified as ACM, the assessed hazard potential is presented along with GSE’ recommended response action. Hazard potential for each material application is based on the material condition and accessibility to the public and maintenance personnel.
Glossary of Items for the following Table
Type of Asbestos (1) CH = Chrysotile AM = Amosite CR = Crocidolite AN = Anthophyllite TR = Tremolite AC = Actinolite ND = No Asbestos Detected PC = Point Count Method
Type of ACM (2) M = Miscellaneous S = Surfacing TSI = Thermal Systems Insulation
Friability (3) F = Friable NF = Non Friable
Physical Condition (4) U = Good D = Damaged SD = Significantly Damaged
Potential for Disturbance (5) NPD = No Potential for Disturbance PD = Potential for Disturbance PSD = Potential for Significant Disturbance
Assessment Category (6) 1 = Damaged or significantly damaged TSI ACBM, 2 = Damaged friable surfacing ACBM 3 = Significantly damaged friable surfacing ACBM 4 = Damaged or significantly damaged friable miscellaneous ACBM 5 = ACBM with potential for damaged 6 = ACBM potential for significant damage 7 = Any remaining friable ACBM or friable suspected
ACBM
X = not applicable
Unit of Measurement SF = Square Feet
LF = Linear Feet
Sample Location
Sample Analyzed
Yes/No
Estimated Quantity of
ACM
Assessment Category
Physical Condition
Friable Yes/No
Type of
ACM
% and Type of Asbestos Detected
Sample ID Potential For
Distrubance
Homogeneous Area 1
Cove Base Tan Cove Base and Mastic
Yes M No U XRoom: 100 Grid: WL1-1
ND - Tan Mastic7 PD
Yes M No U XRoom: 105 Grid: WL1-1
ND - Tan Mastic ND - Cove Base
8 PD
Yes M No U XRoom: 107 Grid: WE2-1
ND - Tan Mastic9 PD
Homogeneous Area 2
12" x 12" Floor Tile Beige Speckled
Yes M No U XRoom: HS117N124 Grid: F1-2
ND - Floor Tile ND - Yellow Mastic
10 PD
Yes M No U XRoom: 120A Grid: F1-1
ND - Floor Tile ND - Yellow Mastic
11 PD
Yes M No U XRoom: 129 Grid: F3-1
ND - Floor Tile ND - Yellow Mastic
12 PD
Sample Location
Sample Analyzed
Yes/No
Estimated Quantity of
ACM
Assessment Category
Physical Condition
Friable Yes/No
Type of
ACM
% and Type of Asbestos Detected
Sample ID Potential For
Distrubance
Homogeneous Area 3
2' X 4' Ceiling Tile Fissured
Yes M Yes U XRoom: 102 Grid: C1-1
ND - Acoustic Tile13 PD
Yes M Yes U XRoom: 108 Grid: C4-1
ND - Acoustic Tile14 PD
Yes M Yes U XRoom: 110 Grid: C4-1
ND - Acoustic Tile15 PD
Homogeneous Area 4
Wall Covering Panel Fibrous
Yes M Yes U XRoom: 102A Grid: WE3-2
ND - Tar Paper ND - Tectum
16 PD
Yes M Yes U XRoom: 102A Grid: WE3-2
ND - Tar Paper ND - Tectum
17 PD
Yes M Yes U XRoom: 102A Grid: WE3-3
ND - Tar Paper ND - Tectum
18 PD
Sample Location
Sample Analyzed
Yes/No
Estimated Quantity of
ACM
Assessment Category
Physical Condition
Friable Yes/No
Type of
ACM
% and Type of Asbestos Detected
Sample ID Potential For
Distrubance
Homogeneous Area 5
Pipe Insulation With Cloth Wrap
Yes TSI Yes U XRoom: 110 Grid: C4-4
ND - Insulation ND - Paper/Tar/Foil Wrap
19 PD
Yes TSI Yes U XRoom: 110 Grid: C4-4
ND - Insulation ND - Paper/Tar/Foil Wrap
20 PD
Yes TSI Yes U XRoom: 110 Grid: C4-4
ND - Insulation ND - Paper/Tar/Foil Wrap
21 PD
Homogeneous Area 6
Pipe Insulation Elbow and Fitting Insulation
Yes 200 Elbows TSI Yes U 1Room: 110 Grid: C4-4
10% CH - Thermal Insulation
22 PD
No TSI Yes U 1Room: 110 Grid: C4-4
Not Analyzed Positive Stop
23 PD
No TSI Yes U 1Room: 110 Grid: C4-4
Not Analyzed Positive Stop
24 PD
Sample Location
Sample Analyzed
Yes/No
Estimated Quantity of
ACM
Assessment Category
Physical Condition
Friable Yes/No
Type of
ACM
% and Type of Asbestos Detected
Sample ID Potential For
Distrubance
Homogeneous Area 7
2' X 2' Ceiling Tile Popcorn Textured
Yes M Yes U XRoom: HS119N100 Grid: C1-4
ND - Acoustic Tile25 PD
Yes M Yes U XRoom: 107 Grid: C3-1
ND - Acoustic Tile26 PD
Yes M Yes U XRoom: 105 Grid: C2-1
ND - Acoustic Tile27 PD
Homogeneous Area 8
Linoleum Floor Covering White with Red Speckles
Yes M No U XRoom: 116 Grid: F4-1
ND - Sheet Flooring ND - Fiber Backing ND - Yellow Mastic
28 PD
Yes M No U XRoom: 107 Grid: F2-1
ND - Sheet Flooring ND - Fiber Backing ND - Yellow Mastic
29 PD
Yes M No U XRoom: 105 Grid: F3-1
ND - Sheet Flooring ND - Fiber Backing
30 PD
Sample Location
Sample Analyzed
Yes/No
Estimated Quantity of
ACM
Assessment Category
Physical Condition
Friable Yes/No
Type of
ACM
% and Type of Asbestos Detected
Sample ID Potential For
Distrubance
Homogeneous Area 9
Wallboard Drywall System
Yes M No U XRoom: 20B Grid: WF3-4
ND - Drywall Material
31 PD
Yes M No U XRoom: 32 Grid: WE1-4
ND - Drywall Material
32 PD
Yes M No U XRoom: 20E Grid: WF2-4
ND - Drywall Material
33 PD
Homogeneous Area 10
Mastic 2' X 2' Multicolored Carpet Squares
Yes M No U XRoom: 108 Grid: F4-1
ND - Green Mastic34 PD
Yes M No U XRoom: 108 Grid: F3-1
ND - Green Mastic35 PD
Yes M No U XRoom: 108 Grid: F1-1
ND - Green Mastic36 PD
Sample Location
Sample Analyzed
Yes/No
Estimated Quantity of
ACM
Assessment Category
Physical Condition
Friable Yes/No
Type of
ACM
% and Type of Asbestos Detected
Sample ID Potential For
Distrubance
Homogeneous Area 11
Pipe Insulation White Pipe Coverings
Yes TSI No U XRoom: 117 Grid: F1-4
ND - Paper /Foil Wrap ND - White Mastic
37 PD
Yes TSI No U XRoom: 117 Grid: F2-4
ND - White Mastic38 PD
Yes TSI No U XRoom: 117 Grid: F3-3
ND - Insulation ND - Paper /Foil Wrap ND - White Mastic
39 PD
Homogeneous Area 12
Mastic Blue/Green Carpet Squares
Yes M No U XRoom: 125 Grid: F4-1
ND - Green Mastic40 PD
Yes M No U XRoom: 125 Grid: F1-1
ND - Green Mastic41 PD
Yes M No U XRoom: 135 Grid: F1-1
ND - Green Mastic42 PD
Sample Location
Sample Analyzed
Yes/No
Estimated Quantity of
ACM
Assessment Category
Physical Condition
Friable Yes/No
Type of
ACM
% and Type of Asbestos Detected
Sample ID Potential For
Distrubance
Homogeneous Area 13
2' X 4' Ceiling Tile Popcorn Textured
Yes M Yes U XRoom: 13 Grid: C1-2
ND - Acoustic Tile43 PD
Yes M Yes U XRoom: 12 Grid: C1-2
ND - Acoustic Tile44 PD
Yes M Yes U XRoom: 12 Grid: C4-1
ND - Acoustic Tile45 PD
Homogeneous Area 14
9" x 9" Floor Tile Green Floor Tile
Yes 1,752 SF M No U 5Room: 110 Grid: F2-3
5% CH - Floor Tile 5% CH - Black Mastic
46 PD
No M No U 5Room: 110 Grid: F1-4
Not Analyzed Positive Stop
47 PD
No M No U 5Room: 104A Grid: F2-3
Not Analyzed
48 PD
Sample Location
Sample Analyzed
Yes/No
Estimated Quantity of
ACM
Assessment Category
Physical Condition
Friable Yes/No
Type of
ACM
% and Type of Asbestos Detected
Sample ID Potential For
Distrubance
Homogeneous Area 15
Mastic Black Cove Base Mastic
Yes M No U XRoom: 110 Grid: WF1-3
ND - Yellow Mastic49 PD
Yes M No U XRoom: 110 Grid: WL1-3
ND - Yellow Mastic50 PD
Yes M No U XRoom: 110 Grid: WR1-1
ND - Yellow Mastic51 PD
Homogeneous Area 16
Cove Base Dark Brown Cove Base and Mastic
Yes M No U XRoom: 108 Grid: WE1-4
ND - Cove Base ND - Yellow Mastic
52 PD
Yes M No U XRoom: 108 Grid: WL1-4
ND - Cove Base ND - Yellow Mastic
53 PD
Yes M No U XRoom: 108 Grid: WF1-1
ND - Cove Base
54 PD
Sample Location
Sample Analyzed
Yes/No
Estimated Quantity of
ACM
Assessment Category
Physical Condition
Friable Yes/No
Type of
ACM
% and Type of Asbestos Detected
Sample ID Potential For
Distrubance
Homogeneous Area 17
Sink Undercoating Black Cove Base Mastic
Yes 10 SF M No U 5Room: 110 Grid: F4-2
5% CH - Sink Undercoating
55 PD
No M No U 5Room: 110 Grid: F4-2
Not Analyzed Positive Stop
56 PD
No M No U 5Room: 110 Grid: F4-2
Not Analyzed Positive Stop
57 PD
Homogeneous Area 18
Mastic Blue/Green Carpet Squares
Yes M No U XRoom: 20 Grid: F2-3
ND - Green Mastic58 PD
Yes M No U XRoom: 11 Grid: F4-1
ND - Green Mastic59 PD
Yes M No U XRoom: 20B Grid: F4-1
ND - Green Mastic60 PD
Sample Location
Sample Analyzed
Yes/No
Estimated Quantity of
ACM
Assessment Category
Physical Condition
Friable Yes/No
Type of
ACM
% and Type of Asbestos Detected
Sample ID Potential For
Distrubance
Homogeneous Area 19
2' X 4' Ceiling Tile Fissured
Yes M Yes U XRoom: 20D Grid: C3-4
ND - Acoustic Tile61 PD
Yes M Yes U XRoom: 20C Grid: C2-4
ND - Acoustic Tile62 PD
Yes M Yes U XRoom: 20B Grid: C1-4
ND - Acoustic Tile63 PD
Homogeneous Area 20
Cove Base Tan Cove Base and Mastic
Yes M No U XRoom: 20 Grid: WR1-3
ND - Tan Mastic ND - Brown Mastic
64 PD
Yes M No U XRoom: 20C Grid: WR1-2
ND - Tan Mastic ND - Brown Mastic
65 PD
Yes M No U XRoom: 20D Grid: WE1-1
ND - Cove Base ND - Tan Mastic ND - Brown Mastic
66 PD
Sample Location
Sample Analyzed
Yes/No
Estimated Quantity of
ACM
Assessment Category
Physical Condition
Friable Yes/No
Type of
ACM
% and Type of Asbestos Detected
Sample ID Potential For
Distrubance
Homogeneous Area 21
2' X 2' Ceiling Tile Popcorn Textured
Yes M Yes U XRoom: 32 Grid: C2-1
ND - Acoustic Tile67 PD
Yes M Yes U XRoom: 32 Grid: C2-4
ND - Acoustic Tile68 PD
Yes M Yes U XRoom: 32 Grid: C4-2
ND - Acoustic Tile69 PD
Homogeneous Area 22
Wallboard Drywall System
Yes M No U XRoom: 19M Grid: WR2-2
ND - Drywall Material ND - Texture
70 PD
Yes M No U XRoom: 15A Grid: WL4-2
ND - Drywall Material
71 PD
Yes M No U XRoom: 19M Grid: WR2-1
ND - Drywall Material
72 PD
Sample Location
Sample Analyzed
Yes/No
Estimated Quantity of
ACM
Assessment Category
Physical Condition
Friable Yes/No
Type of
ACM
% and Type of Asbestos Detected
Sample ID Potential For
Distrubance
Homogeneous Area 23
12" x 12" Floor Tile Beige Speckled
Yes M No U XRoom: 10B Grid: F2-1
ND - Floor Tile ND - Black Mastic
73 PD
Yes M No U XRoom: 10 Grid: F4-4
ND - Floor Tile ND - Black Mastic
74 PD
Yes M No U XRoom: 10C Grid: F4-1
ND - Floor Tile ND - Black Mastic
75 PD
Homogeneous Area 24
Pipe Insulation White Pipe Coverings
Yes M No D XRoom: 19N Grid: F2-2
ND - Gray Mastic76 PD
Yes M No D XRoom: 16 Grid: F2-3
ND - Gray Mastic77 PD
Yes M No D XRoom: 21 Grid: WR1-3
ND - Insulation ND - Gray Mastic
78 PD
Sample Location
Sample Analyzed
Yes/No
Estimated Quantity of
ACM
Assessment Category
Physical Condition
Friable Yes/No
Type of
ACM
% and Type of Asbestos Detected
Sample ID Potential For
Distrubance
Homogeneous Area 25
Mastic Dark Brown Cove Base Mastic
Yes M No U XRoom: 19 Grid: WL4-1
ND - Brown Mastic79 PD
Yes M No U XRoom: 19 Grid: WL4-1
ND - Brown Mastic80 PD
Yes M No U XRoom: 19 Grid: WL4-1
ND - Brown Mastic81 PD
Homogeneous Area 26
Pipe Insulation Gray Pipe Coverings
Yes TSI No U XRoom: 27 Grid: C2-4
ND - Insulation ND - Paper / Foil Wrap ND - Duct Tape ND - Gray Mastic
82 PD
Yes TSI No U XRoom: 27 Grid: C4-4
ND - Insulation ND - Paper / Foil Wrap ND - Gray Mastic
83 PD
Yes TSI No U XRoom: 27 Grid: C4-4
ND - Gray Mastic84 PD
Sample Location
Sample Analyzed
Yes/No
Estimated Quantity of
ACM
Assessment Category
Physical Condition
Friable Yes/No
Type of
ACM
% and Type of Asbestos Detected
Sample ID Potential For
Distrubance
Homogeneous Area 27
Mastic Stair Treads Yes M No U XRoom: 20 Grid: F2-2
ND - Yellow Mastic85 PD
Yes M No U XRoom: 20 Grid: F3-2
ND - Yellow Mastic86 PD
Yes M No U XRoom: 20 Grid: F4-2
ND - Yellow Mastic87 PD
Homogeneous Area 28
Sink Undercoating Gray Yes M No U XRoom: 125 Grid: F4-3
ND - Sink Undercoating
91 PD
Yes M No U XRoom: 125 Grid: F4-3
ND - Sink Undercoating
92 PD
Yes M No U XRoom: 125 Grid: F4-3
ND - Sink Undercoating
93 PD
Sample Location
Sample Analyzed
Yes/No
Estimated Quantity of
ACM
Assessment Category
Physical Condition
Friable Yes/No
Type of
ACM
% and Type of Asbestos Detected
Sample ID Potential For
Distrubance
Homogeneous Area 29
Pipe Insulation White Cloth Coverings
Yes 900 LF TSI Yes U 1Room: 25A Grid: F4-4
65% CH - Gray Insulation ND - Cotton Wrap ND - Yellow Insulation ND - Paper/Tar/Foil Wrap
106 PD
No TSI Yes U 1Room: 19N Grid: F4-2
Not Analyzed Positive Stop
107 PD
No TSI Yes U 1Room: 19N Grid: F3-4
Not Analyzed Positive Stop
108 PD
Homogeneous Area 30
Ceiling Plaster Plaster above Ceiling Tiles
Yes S No SD XRoom: 27 Grid: C2-2
ND - Plaster109 PD
Yes S No SD XRoom: 27 Grid: C1-2
ND - Plaster110 PD
Yes S No SD XRoom: 27 Grid: C1-3
ND - Plaster111 PD
Sample Location
Sample Analyzed
Yes/No
Estimated Quantity of
ACM
Assessment Category
Physical Condition
Friable Yes/No
Type of
ACM
% and Type of Asbestos Detected
Sample ID Potential For
Distrubance
Homogeneous Area 31
Miscellaneous Debris Above Ceiling Tiles
Yes 769 SF M Yes SD 4Room: 27 Grid: C1-1
2% AM - Thermal Insulation 3% CH - Thermal Insulation
112 PD
No M Yes SD 4Room: 27 Grid: C3-3
Not Analyzed Positive Stop
113 PD
No M Yes SD 4Room: 27 Grid: C1-4
Not Analyzed Positive Stop
114 PD
Homogeneous Area 32
2'X 2' Ceiling Tile with pinholes
Yes M Yes U XRoom: 28A Grid: C1-1
ND - Acoustic Tile118 PD
Yes M Yes U XRoom: 28A Grid: C1-4
ND - Acoustic Tile119 PD
Yes M Yes U XRoom: 28A Grid: C4-4
ND - Acoustic Tile120 PD
Sample Location
Sample Analyzed
Yes/No
Estimated Quantity of
ACM
Assessment Category
Physical Condition
Friable Yes/No
Type of
ACM
% and Type of Asbestos Detected
Sample ID Potential For
Distrubance
Homogeneous Area 33
Other Floor Covering Stairs Non Skid Flooring
Yes M No U XRoom: 19 Grid: F2-3
ND - Flooring Material ND - Clear Mastic
121 PD
Yes M No U xRoom: 19 Grid: F2-3
ND - Flooring Material ND - Clear Mastic
122 PD
Yes M No U xRoom: 19 Grid: F2-3
ND - Flooring Material ND - Clear Mastic
123 PD
Homogeneous Area 34
9" x 9" Floor Tile Green Floor Tile
Yes 1,690 SF M No U 5Room: 25 Grid: F3-4
10% CH - Floor Tile 10% CH - Black Mastic
127 PD
No M No U 5Room: 26 Grid: F4-1
Not Analyzed Positive Stop
128 PD
No M No U 5Room: 25 Grid: F3-4
Not Analyzed
129 PD
Sample Location
Sample Analyzed
Yes/No
Estimated Quantity of
ACM
Assessment Category
Physical Condition
Friable Yes/No
Type of
ACM
% and Type of Asbestos Detected
Sample ID Potential For
Distrubance
Homogeneous Area 35
HVAC Duct Insulation Duct Insulation with Canvas Cover
Yes 200 LF TSI No U 5Room: 19N Grid: C3-3
20% CH - Thermal Insulation ND - Canvas Cover
130 PD
No TSI No U 5Room: 19N Grid: C2-3
NA - Positive Stop131 PD
No M No U 5Room: 19N Grid: C2-4
NA - Positive Stop132 PD
Homogeneous Area 36
HVAC Duct Insulation Duct Insulation with Black Mastic
Yes 200 LF TSI No U 5Room: 16 Grid: C3-4
ND - Insulation ND - Paper/Foil Wrap 5% CH - Black Mastic
133 PD
No TSI No U 5Room: 16 Grid: C3-4
NA - Positive Stop134 PD
No TSI No U 5Room: 16 Grid: C2-4
ND - Positive Stop135 PD
1. CH = Chrysotile; AM = Amosite; CR = Crocidolite; AN = Anthophyllite; TR = Tremolite; AC = Actinolite; ND = No Asbestos Detected; or PC = Point Count Method
2. M = Miscellaneous; S = Surfacing; or TSI = Thermal Systems Insulation
3. F = Friable or NF = Non Friable
4. U = Good; D = Damaged; or SD = Significantly Damaged
5. NPD = No Potential for Disturbance; PD = Potential for Disturbance; or PSD = Potential for Significant Disturbance
6. 1 = Damaged or significantly damaged TSI ACBM, 2 = Damaged friable surfacing ACBM, 3 = Significantly damaged friable surfacing ACBM, 4 = Damaged or significantly damaged friable miscellaneous ACBM, 5 = ACBM with potential for damage, 6 = ACBM potential for significant damage, 7 = Any remaining friable ACBM or friable suspected ACBM, or X = not applicable
SF = Square Feet LF = Linear Feet
9. Appendices
Appendix A— Laboratory Results and Chain of Custody Appendix B— ACM Sample Location Drawings Appendix C— ACM Location Diagrams Appendix D— Photographs Appendix E— Certificates and Licenses
Appendix A
Laboratory Results
PLM Summary Report NVLAP Lab No. 102056
TDSHS License No. 30-0084
Client :
Project :
Project # :
Identification :
Test Method :
Great Southern Engineering
MSFC Building 4650
GSE-013
Asbestos, Bulk Sample Analysis
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 8/6/2008, ninety four (94) bulk material samples were submitted by a representative of Great Southern Engineering for asbestos analysis by PLM/DS.
The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Steve Moody Micro Services, LLC
Lab Job No. :
Report Date :
08B-09302
07/28/2008
08/07/2008
2051 Valley View Lane
Farmers Branch, TX 75234 (Phone 972-241-8460)
7 Cove Base Mastic (Tan) None Detected - Tan Mastic
8 Cove Base Mastic (Tan) None Detected - Cove Base
None Detected - Tan Mastic
9 Cove Base Mastic (Tan) None Detected - Tan Mastic
10 12" x 12" Floor Tile (Beige Speckled) None Detected - Floor Tile
None Detected - Yellow Mastic
11 12" x 12" Floor Tile (Beige Speckled) None Detected - Floor Tile
None Detected - Yellow Mastic
12 12" x 12" Floor Tile (Beige Speckled) None Detected - Floor Tile
None Detected - Yellow Mastic
13 2' x 4' Ceiling Tile (Fissured) None Detected - Acoustic Tile
14 2' x 4' Ceiling Tile (Fissured) None Detected - Acoustic Tile
15 2' x 4' Ceiling Tile (Fissured) None Detected - Acoustic Tile
16 Wall and Ceiling Panel None Detected - Tar Paper
None Detected - Tectum
17 Wall and Ceiling Panel None Detected - Tar Paper
None Detected - Tectum
18 Wall and Ceiling Panel None Detected - Tar Paper
None Detected - Tectum
19 Pipe Insulation, Cloth Wrap, Attic None Detected - Insulation
None Detected - Paper/Tar/Foil Wrap
20 Pipe Insulation, Cloth Wrap, Attic None Detected - Insulation
None Detected - Paper/Tar/Foil Wrap
21 Pipe Insulation, Cloth Wrap, Attic None Detected - Insulation
None Detected - Paper/Tar/Foil Wrap
22 Elbow and Fitting Insulation, Attic 10% Chrysotile - Thermal Insulation
TDSHS License No. 30-0084
Client :
Project :
Project # :
Identification :
Test Method :
Great Southern Engineering
MSFC Building 4650
GSE-013
Asbestos, Bulk Sample Analysis
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 8/6/2008, ninety four (94) bulk material samples were submitted by a representative of Great Southern Engineering for asbestos analysis by PLM/DS.
The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Steve Moody Micro Services, LLC
Lab Job No. :
Report Date :
08B-09302
07/28/2008
08/07/2008
2051 Valley View Lane
Farmers Branch, TX 75234 (Phone 972-241-8460)
23 Elbow and Fitting Insulation, Attic Not Analyzed - Positive Stop
24 Elbow and Fitting Insulation, Attic Not Analyzed - Positive Stop
25 2' x 2' Ceiling Tile (Popcorn) None Detected - Acoustic Tile
26 2' x 2' Ceiling Tile (Popcorn) None Detected - Acoustic Tile
27 2' x 2' Ceiling Tile (Popcorn) None Detected - Acoustic Tile
28 Sheet Flooring (White with Red Speckles) None Detected - Sheet Flooring
None Detected - Fiber Backing
None Detected - Yellow Mastic
29 Sheet Flooring (White with Red Speckles) None Detected - Sheet Flooring
None Detected - Fiber Backing
None Detected - Yellow Mastic
30 Sheet Flooring (White with Red Speckles) None Detected - Sheet Flooring
None Detected - Fiber Backing
None Detected - Yellow Mastic
31 Drywall None Detected - Drywall Material
32 Drywall None Detected - Drywall Material
33 Drywall None Detected - Drywall Material
34 2' x 2' Carpet Square (Multicolored) Mastic None Detected - Green Mastic
35 2' x 2' Carpet Square (Multicolored) Mastic None Detected - Green Mastic
36 2' x 2' Carpet Square (Multicolored) Mastic None Detected - Green Mastic
37 Pipe Mastic (White) None Detected - Paper / Foil Wrap
None Detected - White Mastic
38 Pipe Mastic (White) None Detected - White Mastic
39 Pipe Mastic (White) None Detected - Insulation
None Detected - Paper / Foil Wrap
None Detected - White Mastic
TDSHS License No. 30-0084
Client :
Project :
Project # :
Identification :
Test Method :
Great Southern Engineering
MSFC Building 4650
GSE-013
Asbestos, Bulk Sample Analysis
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 8/6/2008, ninety four (94) bulk material samples were submitted by a representative of Great Southern Engineering for asbestos analysis by PLM/DS.
The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Steve Moody Micro Services, LLC
Lab Job No. :
Report Date :
08B-09302
07/28/2008
08/07/2008
2051 Valley View Lane
Farmers Branch, TX 75234 (Phone 972-241-8460)
40 Carpet Square (Blue) Mastic None Detected - Green Mastic
41 Carpet Square (Blue) Mastic None Detected - Green Mastic
42 Carpet Square (Blue) Mastic None Detected - Green Mastic
43 2' x 4' Ceiling Tile (Popcorn) None Detected - Acoustic Tile
44 2' x 4' Ceiling Tile (Popcorn) None Detected - Acoustic Tile
45 2' x 4' Ceiling Tile (Popcorn) None Detected - Acoustic Tile
46 9" x 9" Floor Tile (Green) 5% Chrysotile - Floor Tile
5% Chrysotile - Black Mastic
47 9" x 9" Floor Tile (Green) Not Analyzed - Positive Stop
48 9" x 9" Floor Tile (Green) Not Analyzed - Positive Stop
49 Cove Base Mastic (Black) None Detected - Yellow Mastic
50 Cove Base Mastic (Black) None Detected - Yellow Mastic
51 Cove Base Mastic (Black) None Detected - Yellow Mastic
52 Cove Base Mastic (Dark Brown) None Detected - Cove Base
None Detected - Yellow Mastic
53 Cove Base Mastic (Dark Brown) None Detected - Cove Base
None Detected - Yellow Mastic
54 Cove Base Mastic (Dark Brown) None Detected - Cove Base
None Detected - Yellow Mastic
55 Sink Undercoating (Black) 5% Chrysotile - Sink Undercoating
56 Sink Undercoating (Black) Not Analyzed - Positive Stop
57 Sink Undercoating (Black) Not Analyzed - Positive Stop
58 Carpet Squares (Blue) None Detected - Green Mastic
TDSHS License No. 30-0084
Client :
Project :
Project # :
Identification :
Test Method :
Great Southern Engineering
MSFC Building 4650
GSE-013
Asbestos, Bulk Sample Analysis
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 8/6/2008, ninety four (94) bulk material samples were submitted by a representative of Great Southern Engineering for asbestos analysis by PLM/DS.
The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Steve Moody Micro Services, LLC
Lab Job No. :
Report Date :
08B-09302
07/28/2008
08/07/2008
2051 Valley View Lane
Farmers Branch, TX 75234 (Phone 972-241-8460)
59 Carpet Squares (Blue) None Detected - Green Mastic
60 Carpet Squares (Blue) None Detected - Green Mastic
61 2' x 4' Ceiling Tile (Fissured) None Detected - Acoustic Tile
62 2' x 4' Ceiling Tile (Fissured) None Detected - Acoustic Tile
63 2' x 4' Ceiling Tile (Fissured) None Detected - Acoustic Tile
64 Cove Base Mastic (Tan) None Detected - Tan Mastic
None Detected - Brown Mastic
65 Cove Base Mastic (Tan) None Detected - Tan Mastic
None Detected - Brown Mastic
66 Cove Base Mastic (Tan) None Detected - Cove Base
None Detected - Tan Mastic
None Detected - Brown Mastic
67 2' x 2' Ceiling Tile (Popcorn) None Detected - Acoustic Tile
68 2' x 2' Ceiling Tile (Popcorn) None Detected - Acoustic Tile
69 2' x 2' Ceiling Tile (Popcorn) None Detected - Acoustic Tile
70 Drywall None Detected - Drywall Material
None Detected - Texture
71 Drywall None Detected - Drywall Material
72 Drywall None Detected - Drywall Material
73 12" x 12" Floor Tile (Beige Speckled) None Detected - Floor Tile
None Detected - Black Mastic
74 12" x 12" Floor Tile (Beige Speckled) None Detected - Floor Tile
None Detected - Black Mastic
75 12" x 12" Floor Tile (Beige Speckled) None Detected - Floor Tile
None Detected - Black Mastic
TDSHS License No. 30-0084
Client :
Project :
Project # :
Identification :
Test Method :
Great Southern Engineering
MSFC Building 4650
GSE-013
Asbestos, Bulk Sample Analysis
Polarized Light Microscopy / Dispersion Staining (PLM/DS)
EPA Method 600 / R-93 / 116
Sample Number Client Sample Description / Location Asbestos Content
Sample Date :
On 8/6/2008, ninety four (94) bulk material samples were submitted by a representative of Great Southern Engineering for asbestos analysis by PLM/DS.
The PLM Detail Report is attached; additional information may be found therein. The results are summarized below:
Steve Moody Micro Services, LLC
Lab Job No. :
Report Date :
08B-09302
07/28/2008
08/07/2008
2051 Valley View Lane
Farmers Branch, TX 75234 (Phone 972-241-8460)
76 Pipe Mastic (White) None Detected - Gray Mastic
77 Pipe Mastic (White) None Detected - Gray Mastic
78 Pipe Mastic (White) None Detected - Insulation
None Detected - Gray Mastic
79 Cove Base Mastic (Dark Brown) None Detected - Brown Mastic
80 Cove Base Mastic (Dark Brown) None Detected - Brown Mastic
81 Cove Base Mastic (Dark Brown) None Detected - Brown Mastic
82 Pipe Mastic (Gray) None Detected - Insulation
None Detected - Paper / Foil Wrap
None Detected - Duct Tape
None Detected - Gray Mastic
83 Pipe Mastic (Gray) None Detected - Insulation
None Detected - Paper / Foil Wrap
None Detected - Gray Mastic
84 Pipe Mastic (Gray) None Detected - Gray Mastic