This document is a Clean Space Floor Plan architectural drawing that specifies the layout and dimensions for a controlled environment facility. The facility comprises three main areas: a High Bay space measuring 9 feet in interior height, a Low Bay space measuring 7 feet in interior height, and an Ante/Gowning Room. The overall footprint is 31 feet in length (10 feet plus 21 feet) and 13 feet in width based on the top-down floor plan view.

The High Bay section includes a minimum 3 feet by 7 feet gowning room with a 4 feet by 7 feet minimum additional space, while the Low Bay measures 7 feet tall with interior space specifications. An emergency exit is required from the Cleanspace High Bay area. Window specifications include windows on the upper half of walls in designated locations and windows that match the heights of the low bay windows. A knee wall connects the High Bay to the Low Bay areas. The floor plan indicates door locations, concrete ceiling elements, and specific measurements for lighting placement at 1.5 feet from the bottom of lights and a 2-foot clearance specification. The side view elevation shows the relationship between the two bay heights and the ante/gowning room configuration, with detailed dimensional callouts for construction purposes.

View the file

Other files

File Type Posted
Copy of Attchment 4- Answers to questions Cleanrooms NIST_.xls XLS spreadsheet
LabSpaceFloorPlan.pdf PDF
Cleanspace_top_side.pdf PDF
Outlets_clenspace.pdf PDF
Hallway_floorplan.pdf PDF
RFQ Cleanroom and air handling.docx DOCX document
Attch 4- Questions and Ansers.xls XLS spreadsheet
Attch 3- Past Performance Questionnaire (2).pdf PDF
Attch 2 Provisions and Clauses.docx DOCX document
RFQ Cleanroom and air handling.docx DOCX document
Statement of Req and floor plan.pdf PDF
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Cleanspace High Bay *A

8'

Gowning room 6'

3'x7' min

4'x7' minimum 3'x7' Min

Emergency Exit

*A: Knee wall connecting the Highbay to the low bay areas

High Bay 9 Feet tall Interior space Low Bay 7 Feet tall Interior Space Ante/Gowning Room windows on the upper half of the wall

Windows that match the heights of the low bay windows

1.5' Bottom of Lights

2'

9'

7'

7'

Cleanspace low bay

Clean Space Floor Plan - Side View A

7' 3'6'

Door

2'3'4'

Concrete Ceiling

2'

A windows on the upper half of the wall

Windows that match the heights of the low bay windows

Clean Space Floor Plan - Top down

D o o r

10' 21'