Windows_cleanspace.pdf
PDF 78 KB Posted
- Attached to
- Cleanroom and Air Handling Equipment
- Solicitation number
- NB687000-26-00880
About this file
This document is a Clean Space Floor Plan architectural drawing that specifies the layout and dimensions for a controlled environment facility. The facility comprises three main areas: a High Bay space measuring 9 feet in interior height, a Low Bay space measuring 7 feet in interior height, and an Ante/Gowning Room. The overall footprint is 31 feet in length (10 feet plus 21 feet) and 13 feet in width based on the top-down floor plan view.
The High Bay section includes a minimum 3 feet by 7 feet gowning room with a 4 feet by 7 feet minimum additional space, while the Low Bay measures 7 feet tall with interior space specifications. An emergency exit is required from the Cleanspace High Bay area. Window specifications include windows on the upper half of walls in designated locations and windows that match the heights of the low bay windows. A knee wall connects the High Bay to the Low Bay areas. The floor plan indicates door locations, concrete ceiling elements, and specific measurements for lighting placement at 1.5 feet from the bottom of lights and a 2-foot clearance specification. The side view elevation shows the relationship between the two bay heights and the ante/gowning room configuration, with detailed dimensional callouts for construction purposes.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Copy of Attchment 4- Answers to questions Cleanrooms NIST_.xls | XLS spreadsheet | |
| LabSpaceFloorPlan.pdf | ||
| Cleanspace_top_side.pdf | ||
| Outlets_clenspace.pdf | ||
| Hallway_floorplan.pdf | ||
| RFQ Cleanroom and air handling.docx | DOCX document | |
| Attch 4- Questions and Ansers.xls | XLS spreadsheet | |
| Attch 3- Past Performance Questionnaire (2).pdf | ||
| Attch 2 Provisions and Clauses.docx | DOCX document | |
| RFQ Cleanroom and air handling.docx | DOCX document | |
| Statement of Req and floor plan.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Cleanspace High Bay *A
8'
Gowning room 6'
3'x7' min
4'x7' minimum 3'x7' Min
Emergency Exit
*A: Knee wall connecting the Highbay to the low bay areas
High Bay 9 Feet tall Interior space Low Bay 7 Feet tall Interior Space Ante/Gowning Room windows on the upper half of the wall
Windows that match the heights of the low bay windows
1.5' Bottom of Lights
2'
9'
7'
7'
Cleanspace low bay
Clean Space Floor Plan - Side View A
7' 3'6'
Door
2'3'4'
Concrete Ceiling
2'
A windows on the upper half of the wall
Windows that match the heights of the low bay windows
Clean Space Floor Plan - Top down
D o o r
10' 21'
File details come from the government source that posted it. Updated .