Outlets_clenspace.pdf
PDF 53 KB Posted
- Attached to
- Cleanroom and Air Handling Equipment
- Solicitation number
- NB687000-26-00880
About this file
This document is a Clean Space Floor Plan providing architectural specifications for a controlled environment facility. The overall space measures 31 feet in length by 13 feet in width, with a total layout that includes a main clean room area and an adjacent gowning room. The main clean space is divided into three sections measuring 8 feet, 8 feet, and 4 feet in width, with the full 13-foot depth. The gowning room occupies 8 feet by 6 feet and includes a 3-foot by 7-foot minimum entrance area with a designated door. Two additional access points are specified: a 4-foot by 7-foot minimum equipment door on the left side and a 3-foot by 7-foot minimum door connecting to the gowning room on the right side.
The floor plan includes utility and infrastructure specifications critical to clean room operations. A hot water pipe hangs 1 foot below the ceiling lights in section A, while an HVAC return duct is positioned 2 inches below the lights in section B. The layout designates locations for duplex electrical outlets and indicates ceiling heights of 4 feet in certain sections and 5 feet in the gowning area. The plan provides precise dimensional annotations for structural support, equipment placement, and workflow pathways within the controlled environment. The document serves as a technical blueprint for construction or renovation of a clean manufacturing or laboratory facility.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Copy of Attchment 4- Answers to questions Cleanrooms NIST_.xls | XLS spreadsheet | |
| Windows_cleanspace.pdf | ||
| LabSpaceFloorPlan.pdf | ||
| Cleanspace_top_side.pdf | ||
| Hallway_floorplan.pdf | ||
| RFQ Cleanroom and air handling.docx | DOCX document | |
| Attch 3- Past Performance Questionnaire (2).pdf | ||
| Attch 2 Provisions and Clauses.docx | DOCX document | |
| RFQ Cleanroom and air handling.docx | DOCX document | |
| Statement of Req and floor plan.pdf | ||
| Attch 4- Questions and Ansers.xls | XLS spreadsheet |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
*A: Hot water pipe hangs down, 1ft below the light *B: HVAC return duct hangs down 2" below lights
8' 8' 4'
4'
4'
8'
Gowning room 6'
5' 3'x7' min
8'
4'x7' minimum 3'x7' Min
Equipment Door
Dupex Outlet
4' 3' 2''
A
Door
Clean Space Floor Plan - Top down
10' 21'
D o o r
File details come from the government source that posted it. Updated .