LabSpaceFloorPlan.pdf

PDF 54 KB Posted

Attached to
Cleanroom and Air Handling Equipment
Solicitation number
NB687000-26-00880
Issued by

About this file

This document is a Laboratory Space Floor Plan depicting the layout and spatial requirements for a federal laboratory facility. The plan illustrates a cleanroom environment divided into two primary functional areas: a Cleanspace High Bay and a Cleanspace Low Bay, both designated in green on the diagram. The High Bay section accommodates equipment requiring 8 feet of clearance, while the Low Bay operates at a lower height requirement. A gowning room measuring 2x7 feet minimum is positioned adjacent to the clean spaces to facilitate personnel preparation before entering controlled environments.

The facility incorporates critical infrastructure elements including emergency egress routes with a 3-foot-wide Emergency Exit clearly marked, a Main Laboratory Door for primary access, and additional doors for circulation. A 2-foot dedicated airflow area is designated at the top of the plan for airflow circulation and cleaning, with a yellow zone indicating space specifically intended for air circulation purposes. A 1-foot curb surrounds the clean space boundary to accommodate minor equipment protrusions. The layout includes space for existing and planned equipment installations throughout both clean areas. Emergency exits are positioned to ensure compliance with safety egress requirements, and the overall floor plan demonstrates a structured approach to maintaining cleanroom protocols while accommodating necessary personnel movement and equipment access.

View the file

Other files

File Type Posted
Outlets_clenspace.pdf PDF
Hallway_floorplan.pdf PDF
Copy of Attchment 4- Answers to questions Cleanrooms NIST_.xls XLS spreadsheet
Windows_cleanspace.pdf PDF
Cleanspace_top_side.pdf PDF
RFQ Cleanroom and air handling.docx DOCX document
Statement of Req and floor plan.pdf PDF
Attch 3- Past Performance Questionnaire (2).pdf PDF
Attch 2 Provisions and Clauses.docx DOCX document
RFQ Cleanroom and air handling.docx DOCX document
Attch 4- Questions and Ansers.xls XLS spreadsheet
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

2' dedicated area for airflow intended for airflow circulation and cleaning

Existing/planned Equipment

Cleanspace High Bay

8'

Gowning room 6'

3'x7' min

4'x7' minimum 3'x7' Min

Emergency Exit

Emergency Egress 3'

M a in

L a b o ra ro ry D o o r

Laboratory Space Floor Plan

1' curf around the clean space avaiable for protrusions

Cleanspace low bay

Existing/planned Equipment

Em er ge nc y E xi t

D o o r

Door