(4) EQUAL SPACES AS MEASURED ALONG TOP CHORD
JOIST SEE
PLAN
UPLIFT BRDG NEAR FIRST BOTT
CHORD PANEL POINT (EA END)BRDG
MAY BE LOCATED ON EITHER SIDE OF
JOIST BOTTOM CHORD PANEL POINT
NOTE:
SAMPLE LAYOUT SHOWN FOR (3) ROWS @ TOP CHORD & 5 ROWS @ BOTT CHORD
BRIDGING LAYOUT BY JOIST ENGINEER AND MANUFACTURER.
JOIST BRDG PER MFR
REQUIREMENTS
ALIGN TOP CHORD BRDG
W/ BOTT CHORD BRDG (TYP)
BY
J
O
IS
T M
FR
JO
IS
T
SE
AT
HSS5xHx1/4 (LLH)
BETWEEN
EACH JOIST
H = DENOTES TUBE
HT TO BE
COORDINATED
WITH JOIST SEAT
DEPTHS AND JOIST
MFR
METAL DECK
K-SERIES
JOIST
(BEYOND)
CONT
METAL
ANGLE
3/16 2-12
3/16 2-12
3/16 2-12
3/16 2-12
STL BM
JOIST OVERHANG
*WELD
FULL
LENGTH OF
SEAT (TYP)
K SERIES JOIST
SHORTER THAN
BEAM
K SERIES
JOIST DEEPER
THAN BEAM STEEL BM
UPLIFT BRDG (TYP)
NOTES:
1. STAGGER JOISTS WHERE INDICATED IN PLAN OR AS REQ'D TO OBTAIN 2 1/2"
(MIN) BEARING ON STEEL SUPPORTS. COOR'D AS REQ'D.
2. JOISTS/ROOF SLOPE IS NOT SHOWN FOR CLARITY. REF ROOF FRMG PLAN FOR
SLOPES AS APPLICABLE. PROVIDE FLAT AND LEVEL BEARING SEATS AT ALL
SLOPING ROOF JOISTS IN ORDER TO OBTAIN FULL CONTACT W/ SUPPORTING
MEMBERS. JOIST SEAT DEPTH BY JOIST MANUFACTURER.
3. *BOLT JOISTS AS REQ'D FOR COLUMN STABILITY AND WHERE INDICATED IN PLAN.
METAL DECK
BY
J
O
IS
T M
FR
JS
T
SE
AT
CL BM.
HSS5xHx1/4 (LLH) BETWEEN EACH JOIST
H = DENOTES TUBE HT TO BE
COORDINATED WITH JOIST SEAT DEPTHS
AND JOIST MFR
3/16 2-12
3/16 2-12 TUBE TO
BEAM
INCORRECTCORRECT
ADD JOIST REINFORCING ANGLES FOR CONCENTRATED LOADS
WHICH EXCEED 150 LB AND DO NOT FALL AT A PANEL POINT.
CONCENTRATED LOAD
USE 3"x3" SPACER
WHEN JOIST DEPTH
EXCEEDS 24".
FOR JOIST SIZE, SEE PLAN
PANEL POINT
HANGER LOAD PANEL POINT
(2) L'S 2 1/2x2 1/2x3/16 (NS & FS)
TYP
NOTES:
1. ANGLE BRACES SHALL BE AT MAXIMUM 5 FT O.C.
2. FIELD WELDING OF 1/4" CONNECTION PLATES SHALL BE AT FABRICATORS OPTION.
3. ALL BRACING SHALL BE IN PLACE AND WELDED BEFORE DECK INSTALLATION.
4. BRACE SIZES SHOWN ARE TYPICAL UNLESS OTHERWISE NOTED ON PLAN.
5. REFER TO PLAN NOTES FOR DECK CONSTRUCTION.
L3x3x5/16
CL CLTOP OF DECK
L3x3x5/16
TOP OF DECK
3/16
3/16 TYP
PL 1/4"x6"x0'-6" (TYP)
TYP 3/16
3/16
3/16
3/16 TYP
CL OF PANEL POINT
(TYP)2" MIN
JOIST BRIDGING BY JOIST MFR
WELD OR BOLT TO TOP AND BOTT
FLANGES OF STEEL BM (TYP)
METAL DECK
K-SERIES JOIST
SHORTER THAN BEAMK-SERIES JOIST DEEPER
THAN BEAM
WF BEAM
STEEL
BM
CLCLCL
TYP SUPPORT FOR ALL NON LOAD- BEARING MASONRY PARTITIONS
EXTENDING TO BOTTOM OF DECK, PARALLEL TO STEEL JOISTS
NON LOAD-BRG CMU WALL
CTR BOLTS IN
11/16"x 2"
VERT SLOTTED
HOLES (TYP)
STEEL
JOIST, SEE
PLAN (TYP)
L4x4x1/4x1'-0" W/ (2) 5/8"Ø EXP BOLTS
CTR'D W/ JOIST NS & FS (STAGGER
BOLTS &/OR PLACE VERT LEG UP OR
DOWN TO AVOID CONFLICTS)
HORIZ OR DIAGONAL JOIST BRDG BY JOIST
MFR/ENGINEER, SEE PLAN, WELD OR BOLT ALL
POINTS OF CONTACT (TYP)
U-BLK REINF W/ (1) #5 CONT
@ BOTT CHORD OF JOIST AS SHOWN
1" COMPRESSIBLE FILLER
METAL DECK
U-BLK REINF W/ (1) #5 CONT
@ BOTT CHORD OF JOIST AS SHOWN
L4x4x1/4x1'-0" W/ (2) #10 SELF-
DRILLING SCREWS AT 6" O.C.
EA SIDE OF WALL
SECTION A-A
TYP SUPPORT FOR ALL NON LOAD- BEARING MASONRY PARTITIONS EXTENDING TO
BOTTOM OF DECK, INTERRUPTED BY STEEL FRAMING
L4x4x1/4 x O'-8" CTR'D NS,FS (NOT
REQ'D IF WALL IS BRACED BY
ANOTHER MASONRY WALL PERP TO
THIS WALL W/IN 10'-0" OF JOIST)
1/2" PJF
METAL DECK
STEEL JOIST
U-BLK REINF W/
(1) #5 CONT,
LOCATE IN BLK
COURSE BELOW
BOTT CHORD OF JOIST
U-BLK REINF W/
(1) #5 CONT,
LOCATE IN BLK
COURSE BELOW
BOTT CHORD OF JOIST
A
A
EQ EQ
(±) 0' - 5 1/4"
METAL DECK
1"
COMPRESSIBLE
FILLER
GROUT FULL
WIDTH OF
PARTITION WALL
PENETRATION
CUT MASONRY
CAREFULLY AS
REQUIRED TO
ALLOW JOIST
THRU WALL
L4x4 NOT
SHOWN
FOR
CLARITY
SECTION B-B
L4x4x1/4 x O'-8" CTR'D NS,FS (NOT
REQ'D IF WALL IS BRACED BY
ANOTHER MASONRY WALL PERP TO
THIS WALL W/IN 10'-0" OF JOIST)
1/2" PJF
METAL DECK
STEEL JOIST
U-BLK REINF W/
(1) #5 CONT,
LOCATE IN BLK
COURSE BELOW
BOTT CHORD OF JOIST
U-BLK REINF W/
(1) #5 CONT,
LOCATE IN BLK
COURSE BELOW
BOTT CHORD OF JOIST
B
B
EQ EQ
(±) 0' - 5 1/4"
METAL DECK
1" COMPRESSIBLE FILLER GROUT FULL
WIDTH OF
PARTITION WALL
PENETRATIONCUT MASONRY
CAREFULLY AS
REQUIRED TO
ALLOW JOIST
THRU WALL
L4x4 NOT
SHOWN
FOR
CLARITY
STEEL JOIST STEEL BEAM
WALL PARALLEL TO JOIST
TYP SUPPORT FOR ALL NON LOAD- BEARING MASONRY
PARTITIONS NOT EXTENDING TO BOTTOM OF DECK
WALL PERPENDICULAR TO JOIST
L3x3x1/4 @ 10'-0" OC
MAX (TYP)
L2x2x1/4 @ EACH
BRIDGING LINE
NOTE:
WALLS MAY BE CONSIDERED FULLY BRACED
AT INTERSECTIONS. STEEL SUPPORTS ARE
NOT REQUIRED AT THESE LOCATIONS.
JOIST OR BM (TYP)
0'
1" 0'
1"
3/16
TYP
3/16
TYP
3/16
TYP
3/16
TYP
8" CMU REINF W/(1) #5
CONT
NON LOAD-BEARING WALL
L3x3x1/4x1'-0" EA SIDE OF WALL
L2x2x1/4x1'-4"
3/16
TYP
L6x4x1/4x0'-6"
(LLV) @ JOIST
PANEL POINT (TYP)
L3x3x1/4 @ 10'-0" OC MAX (TYP)
8" CMU REINF W/(1) #5
CONT
NON LOAD-BEARING WALL
L3x3x1/4x1'-0" EA SIDE OF WALL
L2x2x1/4x1'-4"
JOIST
OR BM (TYP)
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 7 FEBRUARY 2019
DESIGN MANAGER
PROJECT MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
VA
L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
YS
TE
M S
C O
M M
A N
D
S O
U
TH
E A
S T
N
AV
AL
A
IR
S
TA
TI
O N
J
AC
KS
O
N
VI
LL
E
AS NOTED
AECOM Technical Services, Inc.
7650 West Courtney Campbell Causeway Tampa, FL 33607 Tel: 813-286-1711
FDBPR LICENSE NO. CA8115
1 2 3 4 5
DEEAS
AH ASS
I
N
N
STATE
OF
S
NI O AL E
O F
ES I
G
R E E
N
NO.
42590P
R
FL RIO AD
ESI ENCL
SAEED HASSANI
LICENSE NO. 42590
S-509
P -6
TY
PI
CA
L
ST
EE
L
JO
IS
T
DE
TA
IL
S
/ S
EC
TI
O
NS
GRP
15174040
NJB VVW
N U
C
LE
A R
R E
G
IO
N A
L M
A
IN
TE
N
A N
C E
F A
C
IL
IT
Y
JASON WHITEHEAD
1611490
AMY HOFFER
ANTHONY DISANTO
NA
VA
L S
UB
MA
RI
NE
B
AS
E, K
IN
GS
B
AY
, G
A
NTS1 TYPICAL MINIMUM JOIST BRIDGING DETAIL
NTSC
TYP DECK ATTACHMENT BETWEEN K-SERIES
JOISTS BEARING ON STEEL BEAMS
NTSA
TYP K-SERIES ROOF JOIST FRMG @ STEEL
BEAM
NTS3
TYP JOIST REINFORCEMENT @
CONCENTRATED LOADS
NTS2
TYP BOTTOM FLANGE BRACE (AT STEEL
JOIST)
NTS4 TYP ROOF JOIST BRIDGING @ STEEL BEAM
NTSB SECTION
NTSD DETAIL
NTSE SECTION
(TYP)
(TYP)
(TYP)
SY
M
DE
S C
RI
PT
I O N
DA
TE
AP
PR
W
AL
L G
AP
A
T M
ET
AL
D
E C K
CL
AR
IF
IC
AT
IO
N 6/8
/20
SB
H
| Sheets |
| S-509 - TYPICAL STEEL JOIST DETAILS / SECTIONS |