2021-07-22 35pct Dwgs Package A (ContractorPackage)_Part5.pdf
PDF 28 MB Posted
- Attached to
- INDUSTRY DAY FOR FY23 MCON P-209 DRY DOCK 3 REPLACEMENT, JOINT BASE PEARL HARBOR-HICKAM, HAWAII
- Solicitation number
- N62742SIOPINDUS
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MA
TC
H
LIN
E
RE
FE
R
TO
A
1 / M
Z1
MA
TC
H
LIN
E
RE
FE
R
TO
A
1 / M
Z1
DRY DOCK 5 KEY PLAN
DRY DOCK 4
DRY DOCK 2
DRY DOCK 3
DRY DOCK 1
DRY
DOCK 5
PEARL HARBOR
N O
T
FO
R
CO
N
ST
RU
CT
IO
N
P R
E L
IM
IN
A
R Y
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N
AV
FA
C
P
AC
IF
IC
AS NOTED
M
AK
AL
AP
A, H
AW
AI
I
PE
AR
L
H
AR
BO
R
N
AV
AL
S
H
IP
YA
R
D
IM
F
DR
Y
DO
CK
R
EP
LA
CE
M
EN
T
1676443
UNCLASSIFIED//FOR OFFICIAL USE ONLY
AP
PR
D
AT
E D
ES
C
R
IP
TI
O
N
SY
M
UNCLASSIFIED//FOR OFFICIAL USE ONLY
U N
C
LA
SS
IF
IE
D
//F O
R O
FF
IC
IA
L
U
SE
O N
LY
PL
OT
TE
D:
FI
LE
N
AM
E:
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWING35% SUBMITTAL - 3 JUNE 2021
5/
/2
:1 4:
A
M C
:\U se rs \c st ill
\O ne
D riv e
- B ur ns
M cD on ne ll\
D oc um en ts \D
R
YD
P2
-1
-M W
-B W
TS
_c st ill
.rv t
MZ103
BA
SI
N W
AT
ER
T
RE
AT
ME
NT
E
NL
AR
GE
D
PL
AN
RMHSAS CLS
1/4" = 1'-0"A1 BASIN WATER TREATMENT ENLARGED PLAN 3
GENERAL NOTES
SHEET KEYNOTES
FWTS-FW-FLT-401
FWTS-FW-FLT-401FWTS-FW-FLT-301
FWTS-FW-FLT-402
FWTS-FW-FLT-302
FWTS-FW-GOWS-202 FWTS-FW-GOWS-201
6"⌀ BW
FWTS-FW-P-202
FWTS-FW-P-201
8"⌀ BW
6"⌀ TW2"⌀ AL
8"⌀ BW
8"⌀ BW
6"⌀ BW
3"⌀ BW
6"⌀ TW
6"⌀ TW
4"⌀ BW
4"⌀ BW
N
2' 4' 8'0'
FWTS-FW-P-101
FWTS-FW-P-102
BWTS
2"⌀ W
35% SUBMITTAL - 3 JUNE 2021 (PACKAGE A)
PRE-DECISIONAL
12.40'
TOC 24.40'
CL EL 18.68'
CL EL 14.73'
13.73'
N O
T
FO
R
CO
N
ST
RU
CT
IO
N
P R
E L
IM
IN
A
R Y
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N
AV
FA
C
P
AC
IF
IC
AS NOTED
M
AK
AL
AP
A, H
AW
AI
I
PE
AR
L
H
AR
BO
R
N
AV
AL
S
H
IP
YA
R
D
IM
F
DR
Y
DO
CK
R
EP
LA
CE
M
EN
T
1676443
UNCLASSIFIED//FOR OFFICIAL USE ONLY
AP
PR
D
AT
E D
ES
C
R
IP
TI
O
N
SY
M
UNCLASSIFIED//FOR OFFICIAL USE ONLY
U N
C
LA
SS
IF
IE
D
//F O
R O
FF
IC
IA
L
U
SE
O N
LY
PL
OT
TE
D:
FI
LE
N
AM
E:
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWING35% SUBMITTAL - 3 JUNE 2021
5/
/2
:1 6:
A
M C
:\U se rs \c st ill
\O ne
D riv e
- B ur ns
M cD on ne ll\
D oc um en ts \D
R
YD
P2
-1
-M W
-B W
TS
_c st ill
.rv t
MZ300
BA
SI
N W
AT
ER
T
RE
AT
ME
NT
S
EC
TI
ON
RMHSAS CLS
1/4" = 1'-0"A1 MZ SECTION A
GENERAL NOTES
SHEET KEYNOTES
BWTS-BW-T-102 BWTS-BW-T-101
8"⌀ BW
6"⌀ BW
14"⌀ BW
6"⌀ BW
6"⌀ BW
14"⌀ BW
6"⌀ BW
8"⌀ BW
4"⌀ BW
6"⌀ BW
2"⌀ W
2' 4' 8'0'
N3N1
N10
N4
N7
N9
N7
N9
N6 N6 N4
N3 N1
N11/N12 M3
N10 N11/N12
M3
CL EL 23.90'
CL EL 24.82'
CL EL 14.73'
13.73'
CL EL 18.68'
N O
T
FO
R
CO
N
ST
RU
CT
IO
N
P R
E L
IM
IN
A
R Y
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N
AV
FA
C
P
AC
IF
IC
AS NOTED
M
AK
AL
AP
A, H
AW
AI
I
PE
AR
L
H
AR
BO
R
N
AV
AL
S
H
IP
YA
R
D
IM
F
DR
Y
DO
CK
R
EP
LA
CE
M
EN
T
1676443
UNCLASSIFIED//FOR OFFICIAL USE ONLY
AP
PR
D
AT
E D
ES
C
R
IP
TI
O
N
SY
M
UNCLASSIFIED//FOR OFFICIAL USE ONLY
U N
C
LA
SS
IF
IE
D
//F O
R O
FF
IC
IA
L
U
SE
O N
LY
PL
OT
TE
D:
FI
LE
N
AM
E:
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWING35% SUBMITTAL - 3 JUNE 2021
5/
/2
:1 7:
A
M C
:\U se rs \c st ill
\O ne
D riv e
- B ur ns
M cD on ne ll\
D oc um en ts \D
R
YD
P2
-1
-M W
-B W
TS
_c st ill
.rv t
MZ301
BA
SI
N W
AT
ER
T
RE
AT
ME
NT
S
EC
TI
ON
RMHSAS CLS
1/4" = 1'-0"A1 MZ SECTION B
GENERAL NOTES
SHEET KEYNOTES
BWTS-BW-T-102BWTS-BW-T-101
2' 4' 8'0'
8"⌀ BW
6"⌀ FM
6"⌀ BW
6"⌀ BW6"⌀ BW
4"⌀ BW
4"⌀ BW
M2 M1 M2 M1
N8 N8
N5
N2N2
N5
N10 N11/N12
M3
N10 N11/N12
M3
TOC 12.86' 12.86'
12.91'
CL EL 22.15'
CL EL 22.90'
CL EL 23.90'
CL EL 22.15'
CL EL 22.90'
TOC 12.84' TOC 12.90'
N O
T
FO
R
CO
N
ST
RU
CT
IO
N
P R
E L
IM
IN
A
R Y
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N
AV
FA
C
P
AC
IF
IC
AS NOTED
M
AK
AL
AP
A, H
AW
AI
I
PE
AR
L
H
AR
BO
R
N
AV
AL
S
H
IP
YA
R
D
IM
F
DR
Y
DO
CK
R
EP
LA
CE
M
EN
T
1676443
UNCLASSIFIED//FOR OFFICIAL USE ONLY
AP
PR
D
AT
E D
ES
C
R
IP
TI
O
N
SY
M
UNCLASSIFIED//FOR OFFICIAL USE ONLY
U N
C
LA
SS
IF
IE
D
//F O
R O
FF
IC
IA
L
U
SE
O N
LY
PL
OT
TE
D:
FI
LE
N
AM
E:
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWING35% SUBMITTAL - 3 JUNE 2021
5/
/2
:2 5:
A
M C
:\U se rs \c st ill
\O ne
D riv e
- B ur ns
M cD on ne ll\
D oc um en ts \D
R
YD
P2
-1
-M W
-B W
TS
_c st ill
.rv t
MZ302
BA
SI
N W
AT
ER
T
RE
AT
ME
NT
S
EC
TI
ON
RMHSAS CLS
1/4" = 1'-0"C1 MZ SECTION C
1/4" = 1'-0"C3 MZ SECTION D
1/4" = 1'-0"A1 MZ SECTION E
GENERAL NOTES
SHEET KEYNOTES
BWTS-BW-GOWS-202
BWTS-BW-GOWS-202BWTS-BW-GOWS-201BWTS-BW-P-202
BWTS-BW-FLT-301
BWTS-BW-FLT-302
1/4" = 1'-0"A2 MZ SECTION F
BWTS-BW-FLT-301
BWTS-BW-FLT-401
BWTS-BW-P-201 BWTS-BW-P-202
2' 4' 8'0' 2' 4' 8'0'
2' 4' 8'0'2' 4' 8'0'
6"⌀ BW
8"⌀ BW
6"⌀ BW
8"⌀ BW
3"⌀ BW
6"⌀ BW
6"⌀ BW
3"⌀ BW4"⌀ BW
2"⌀ AL
6"⌀ BW
6"⌀ TE
6"⌀ TW
6"⌀ BW
23.82'
23.90'
12.73' 13.90'
N O
T
FO
R
CO
N
ST
RU
CT
IO
N
P R
E L
IM
IN
A
R Y
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N
AV
FA
C
P
AC
IF
IC
AS NOTED
M
AK
AL
AP
A, H
AW
AI
I
PE
AR
L
H
AR
BO
R
N
AV
AL
S
H
IP
YA
R
D
IM
F
DR
Y
DO
CK
R
EP
LA
CE
M
EN
T
1676443
UNCLASSIFIED//FOR OFFICIAL USE ONLY
AP
PR
D
AT
E D
ES
C
R
IP
TI
O
N
SY
M
UNCLASSIFIED//FOR OFFICIAL USE ONLY
U N
C
LA
SS
IF
IE
D
//F O
R O
FF
IC
IA
L
U
SE
O N
LY
PL
OT
TE
D:
FI
LE
N
AM
E:
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWING35% SUBMITTAL - 3 JUNE 2021
5/
/2
:2 8:
A
M C
:\U se rs \c st ill
\O ne
D riv e
- B ur ns
M cD on ne ll\
D oc um en ts \D
R
YD
P2
-1
-M W
-B W
TS
_c st ill
.rv t
MZ303
BA
SI
N W
AT
ER
T
RE
AT
ME
NT
S
EC
TI
ON
RMHSAS CLS
1/4" = 1'-0"A1 MZ SECTION G
GENERAL NOTES
SHEET KEYNOTES
BWTS-BW-T-102
BWTS-BW-P-102
4"⌀ BW
6"⌀ BW
4"⌀ BW
6"⌀ BW
6"⌀ BW6"⌀ BW
4"⌀ BW
6"⌀ BW
6"⌀ BW
4"⌀ BW14"⌀ BW
6"⌀ BW
8"⌀ BW
6"⌀ BW
2' 4' 8'0'
N10
N5N2 N4
N6N3
N8
N9
N6
M1
N O
T
FO
R
CO
N
ST
RU
CT
IO
N
P R
E L
IM
IN
A
R Y
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N
AV
FA
C
P
AC
IF
IC
AS NOTED
M
AK
AL
AP
A, H
AW
AI
I
PE
AR
L
H
AR
BO
R
N
AV
AL
S
H
IP
YA
R
D
IM
F
DR
Y
DO
CK
R
EP
LA
CE
M
EN
T
1676443
UNCLASSIFIED//FOR OFFICIAL USE ONLY
AP
PR
D
AT
E D
ES
C
R
IP
TI
O
N
SY
M
UNCLASSIFIED//FOR OFFICIAL USE ONLY
U N
C
LA
SS
IF
IE
D
//F O
R O
FF
IC
IA
L
U
SE
O N
LY
PL
OT
TE
D:
FI
LE
N
AM
E:
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWING35% SUBMITTAL - 3 JUNE 2021
5/
/2
:2 9:
A
M C
:\U se rs \c st ill
\O ne
D riv e
- B ur ns
M cD on ne ll\
D oc um en ts \D
R
YD
P2
-1
-M W
-B W
TS
_c st ill
.rv t
MZ601
BA
SI
N W
AT
ER
T
RE
AT
ME
NT
S
CH
ED
UL
ES
RMHSAS CLS
M3 MANWAY FLANGED 24" 316 SS 12'-8" --- 180 0
M2 MANWAY FLANGED 24" 316 SS --- 13'-9" 135 140
M1 MANWAY FLANGED 24" 316 SS --- 13'-9" 40 45
N12 LEVEL TRANSMITTER FLANGED 4" 316 SS 8'-3" --- 195 345
N11 LEVEL SWITCH FLANGED 4" 316 SS 8'-3" --- 165 15
N10 VENT FLANGED 14" 316 SS 0'-0" --- 0 0
N9 DRAIN FLANGED 4" 316 SS --- 14'-0" 330 210
N8 BWTS OUTLET FLANGED 6" 316 SS --- 14'-3" 90 90
N7 CROSS CONNECT BOTTOM FLANGED 10" 316 SS --- 14'-9" 315 225
N6 CROSS CONNECT TOP FLANGED 10" 316 SS --- 51'-3" 315 225
N5 RECIRC INLET FLANGED 6" 316 SS --- 51'-5" 20 160
N4 OVERFLOW FLANGED 14" 316 SS --- 52'-3" 335 105
N3 GALLERY INLET FLANGED 6" 316 SS --- 51'-3" 285 255
N2 FILTER REJECT INLET FLANGED 4" 316 SS --- 51'-5" 10 170
N1 PUMPHOUSE INLET FLANGED 8" 316 SS --- 51'-3" 270 270
BWTS-BW-T-101 BWTS-BW-T-102
NOZZLE NO. FUNCTION TYPE SIZE MATERIAL DISTANCE FROM
CENTER (FT-IN) ELEVATION (FT-IN)
ORIENTATION (DEG)
REMARKS
BASIN WATER TREATMENT STORAGE TANK NOZZLE SCHEDULE
BWTS-BW-P-402 BWTS EQUIPMENT CONTAINMENT SUM... SUBMERSIBLE 75 60 NA 2 120 6-8 1.0 - 1.02 1.0 - 1.1 3450 5 460 3 60 FIXED BWTS-BW-P-401 BWTS EQUIPMENT CONTAINMENT SUM... SUBMERSIBLE 75 60 NA 2 120 6-8 1.0 - 1.02 1.0 - 1.1 3450 5 460 3 60 FIXED BWTS-BW-P-302 BWTS TANK CONTAINMENT SUMP PUMP SUBMERSIBLE 75 60 NA 2 120 6-8 1.0 - 1.02 1.0 - 1.1 3450 5 460 3 60 FIXED BWTS-BW-P-301 BWTS TANK CONTAINMENT SUMP PUMP SUBMERSIBLE 75 60 NA 2 120 6-8 1.0 - 1.02 1.0 - 1.1 3450 5 460 3 60 FIXED BWTS-BW-P-202 DISC FILTER FEED PUMP HORIZONTAL... 350 120 3 2 120 6-8 1.0 - 1.02 1.0 - 1.1 1750 20 460 3 60 VFD - LEVEL BWTS-BW-P-201 DISC FILTER FEED PUMP HORIZONTAL... 350 120 3 2 120 6-8 1.0 - 1.02 1.0 - 1.1 1750 20 460 3 60 VFD - LEVEL BWTS-BW-P-102 OWS FEED PUMP ROTARY LOBE 350 46 6 6 120 6-8 1.0 - 1.02 1.0 - 1.1 1750 15 460 3 60 VFD - FLOW BWTS-BW-P-101 OWS FEED PUMP ROTARY LOBE 350 46 6 6 120 6-8 1.0 - 1.02 1.0 - 1.1 1750 15 460 3 60 VFD - FLOW
MAX TEMP
(DEG F) pH
SPECIFIC
GRAVITY
VISCOSITY
(cP)
MOTOR
SPEED (RPM) HP VOLTS PH HZ
SPEED
CONTROL
TYPEMARK SERVICE PUMP TYPE
DESIGN
CAPACITY (GPM)
DESIGN HEAD
(FT WC)
SUCTION
SIZE(IN)
DISCHARGE
SIZE (IN)
FLUID CHARACTERISTICS ELECTRICAL DATA
REMARKS
BASIN WATER TREATMENT PUMP SCHEDULE
BWTS -BW-T-102 BASIN WATER STORAGE TANK 316LSS 211,500 175,000 120 ATM ATM 1.02 30 40 CONE SLOPED SPIRAL STAIR AND ACCESS PLATFORM BWTS -BW-T-101 BASIN WATER STORAGE TANK 316LSS 211,500 175,000 120 ATM ATM 1.02 30 40 CONE SLOPED SPIRAL STAIR AND ACCESS PLATFORM
MARK DESCRIPTION GAL GAL DEG F PSIG PSIG FT FT
MATERIAL VOLUME VOLUME TEMP. PRESS VACUUM GRAVITY DIAMETER HEIGHT TOP BOTTOM COMMENTS
WORKING MAX. MAX MAX SPECIFIC SIDE
BASIN WATER TREATMENT STORAGE TANK SCHEDULE
NOTES:
1. 316LSS = 316 L STAINLESS STEEL
2. PASSIVATION OF TANKS REQUIRED. REFER TO SECTION XX.XX.XX.
3. STAIRS AND PLATFORM ON BWTS-BW-T-101 TO BE COORDINATED WITH CONTRACTOR PROVIDED CONTAINMENT AREA ACCESS PLATFORM AND STAIRS.
NOTES:
1. BOTTOM OF TANK ELEVATION 13'-9"
2.
Y-TYPE STRAINER
CONE STRAINER
T-TYPE STRAINER
DUPLEX STRAINER
BASKET STRAINER
REMOVABLE SPOOL
FLEXIBLE HOSE
HOSE CONNECTION
FLANGE
CAP
ECCENTRIC REDUCER
PLUG
BLIND FLANGE
GATE (OR GENERIC)
CHECK
STOP CHECK
GLOBE
NEEDLE
3-WAY
4-WAY
PINCH
ANGLE
KNIFE
BUTTERFLY
BALL
GENERIC ROTARY (1/4 TURN)
PLUG
DIAPHRAGM
VALVE SYMBOLS PIPING SPECIALTY ITEMS PIPING LINE SYMBOLS
PIPING FITTINGS
PRIMARY/SECONDARY LINES AND INSTRUMENT SIGNAL CONNECTOR
OPEN DRAIN
OPEN DRAIN (NO P&ID)
OFF-PAGE & DRAIN CONNECTORS
OFF-PLOT CONNECTOR
CONNECTOR NUMBER
DESTINATION LINE
SERVICE CODE
CONNECTOR NUMBER
CONNECTOR NUMBER
WELDED CONNECTION
CONCENTRIC (OR GENERIC)
DESTINATION
LINE SERVICE CODE
PRIMARY (AG & UG)
SECONDARY / UTILITY (AG & UG)
FUTURE & EXISTING ON NEW P&IDs
BLANK
SPACER
SERVICE DESCRIPTION
ORIGIN/DESTINATION
XXXX P&ID NO
SERVICE DESCRIPTION
ORIGIN/DESTINATION
XXXX P&ID NO
XXXXX
YYY
P&ID NO
YYY
ABBREVIATIONS
AG ABOVE GROUND
ATM ATMOSPHERE
BL BATTERY LIMITS
BTL BOTTOM TANGENT LINE
BYP BYPASS
CL CENTERLINE
CO CLEANOUT
CONN CONNECTION
CH CHECK VALVE
CTR CENTER
DCS DISTRIBUTED CONTROL SYSTEM
DES DESIGN
DIA DIAMETER
DP DESIGN PRESSURE
D/P DIFFERENTIAL PRESSURE
DRN DRAIN
DT DESIGN TEMPERATURE
DWG DRAWING
(E) EXISTING
EL ELEVATION
ESD EMERGENCY SHUTDOWN
FOF FACE OF FLANGE
(F) FURNISHED
FC FAIL CLOSED
FI FAIL INTERMEDIATE
FL FAIL LOCKED (LAST POSITION)
FLG FLANGE
FO FAIL OPEN
FP FULL PORT
GR GRADE
HC HOSE CONNECTION
HDR HEADER
HH HAND HOLE
HOA HAND/OFF/AUTOMATIC
HA HAND/AUTOMATIC
HP HIGH PRESSURE
HPT HIGH POINT
HYPO SODIUM HYPOCHLORITE
IAS INSTRUMENT AIR SUPPLY
LC LOCKED CLOSED
LO LOCKED OPEN
LP LOW PRESSURE
LPT LOW POINT
MAX MAXIMUM
MIN MINIMUM
MOV MOTOR OPERATED VALVE
MTL MATERIAL
MW MANWAY
NAOCL SODIUM HYPOCHLORITE
NC NORMALLY CLOSED
NNF NORMALLY NO FLOW
NO NORMALLY OPEN
O/C OPEN/CLOSE
O/O ON/OFF
OP OUTPUT
OVHD OVERHEAD
PRESS PRESSURE
PV PROCESS VARIABLE
(R) RELOCATED
REQD REQUIRED
RTD RESISTANCE TEMP. DETECTOR
SBS SODIUM BISULFITE
SC SAMPLE CONNECTION
SCH SCHEDULE
SD SHUTDOWN
SG SPECIFIC GRAVITY
SP SET POINT
SS STAINLESS STEEL
S/S START/STOP
STD STANDARD
T/C THERMOCOUPLE
TDH TOTAL DIFFERENTIAL HEAD
TEMP TEMPERATURE
THRD THREADED
TL TANGENT LINE
TSO TIGHT SHUT-OFF
T/T TANGENT TO TANGENT
TYP TYPICAL
UG UNDERGROUND
VNT VENT
VAC VACUUM
VB VORTEX BREAKER
W/ WITH
W/O WITHOUT
BIDIRECTIONAL CONNECTOR NUMBER
SERVICE DESCRIPTION
ORIGIN/DESTINATION
XXXX P&ID NO
BIDIRECTIONAL CONNECTOR NUMBER
SERVICE DESCRIPTION
ORIGIN/DESTINATION
XXXX P&ID NO
AV ATMOSPHERIC VENT
BA BREATHING AIR
BD BLOWDOWN
BFW BOILER FEED WATER
BRR BRINE RETURN
BRS BRINE SUPPLY
CC CONTAMINABLE CONDENSATE
CF COLD FLARE
CHS CHEMICAL SEWER
CV COLD VENT
CWR COOLING WATER RETURN
CWS COOLING WATER SUPPLY
DMW DEMINERALIZED WATER
DR DRAIN
DS DILUTION STEAM
DW DRINKING WATER
ER ETHYLENE REFRIGERANT
FF FLUSHING FLUID
FG FUEL GAS
FO FUEL OIL
FW FIRE WATER
GLR GLYCOL RETURN
GLS GLYCOL SUPPLY
H HYDROGEN
HS HIGH PRESSURE STEAM
IA INSTRUMENT AIR
IS INTERMEDIATE PRESSURE STEAM
LNG LIQUEFIED NATURAL GAS
LO LUBE OIL
LPG LIQUEFIED PETROLEUM GAS
LS LOW PRESSURE STEAM
ME METHANOL
NAOCL SODIUM HYPOCHLORITE
NAS CAUSTIC SEWER
NG NATURAL GAS
NH AMMONIA
OWS OILY WATER SEWER
OX OXYGEN
P GENERAL PROCESS
PA PLANT AIR
PC PROCESS CONDENSATE
PR PROPYLENE REFRIGERANT
PW PURE WATER
QO QUENCH OIL
RS RECOVERED SLOPS
RV RELIEF VENT
RW RAW WATER
SBS SODIUM BISULFITE
SC STEAM CONDENSATE
SG SYNTHESIS GAS
SO SEAL OIL
SS SANITARY SEWER
SW SERVICE WATER
SWR SEA WATER RETURN
SWS SEA WATER SUPPLY
TWR TEMPERED WATER RETURN
TWS TEMPERED WATER SUPPLY
VC VACUUM CONDENSATE
VE VACUUM EXHAUST
WF WARM FLARE
WO WASH OIL
WW WASTE WATER
SYSTEM/LINE SERVICE CODES EQUIPMENT/COMPONENT CLASSIFICATION
1. ALL SINGLE VALVE CONNECTIONS TO ATMOSPHERE IN PROCESS SERVICE WILL BE
PLUGGED, CAPPED, OR BLIND FLANGED.
2. ALL VENTS AND DRAINS ARE 1/2" UNLESS OTHERWISE NOTED.
3. DEFINITIONS:
ELEVATIONS DOWNSTREAM NEVER
GRAVITY FLOW - EXCEED INLET ELEVATIONS. LINE MAY
CONTAIN POCKETS.
- SLOPED LINE: NO POCKETS PERMITTED.
NO POCKETS - NO POCKETS
4. FLOW ASSUMED LEFT TO RIGHT AS SHOWN.
5. VALVES WHICH ARE NORMALLY CLOSED ARE SO INDICATED BY "DARKENED IN"
SYMBOL.
EXAMPLE:
NORMALLY CLOSED GATE VALVE
NORMALLY CLOSED BUTTERFLY VALVES ARE INDICATED BY THE ABBREVIATION
"NC".
GENERAL CONTROLS NOTES
COUPLING
GOOSE NECK VENT
REDUCER
CALIBRATION COLUMN
FILTER (E-EDGE, F-FIBER)
VENT TO ATMOSPHERE
E
VENT WITH SCREEN
PIPING LINE IDENTIFICATION
LPA-AHP-1"-PC-1-101-N
SYSTEM CODE
NOMINAL PIPE SIZE
TUBING O.D. (INCHES)
PIPE LINE SEQUENCE NO.
PIPING CLASS SHEET
INSULATION PURPOSE
EQUIPMENT IDENTIFICATION
LPA-AHP-T-001
SYSTEM CODE
SEQUENCE NUMBER 001-999
EQUIPMENT CODE
PIPING SPECIALS IDENTIFICATION
LPA-AHP-F-001
COMPONENT CODE
SYSTEM CODE
SEQUENCE NUMBER 001-999
LPA-AHP-V-001
VALVE STATUS
VALVE SEQUENCE NUMBER
SYSTEM CODE
NC NORMALLY CLOSED ( )
NO NORMALLY OPEN ( )
LS LOCKED SHUT
LO
NOTE:
LOCKED OPEN
VENT, DRAIN AND BYPASS VALVES
ARE NORMALLY SHUT AND ALL
OTHERS ARE NORMALLY OPEN
UNLESS SPECIFIED OTHERWISE.
VALVE FAIL POSITIONS
FS FAIL SHUT
FO FAIL OPEN
FAI FAIL AS IS
VALVE IDENTIFICATION
M MIXER
F FITTING
BFP BACKFLOW PREVENTER
MS MOTOR STARTER
P PUMP
D
T
DEMINERALIZER
TANK
GAC GRANULAR ACTIVATED CARBON
OGC ORGANO CLAY
GOWS GRAVITY OIL WATER SEPARATOR
NG NITROGEN GENERATOR
FDM FINAL POLISHING DEMINERALIZER
V VALVE
RO REVERSE OSMOSIS
DBS DUPLEX BASKET STRAINER
CC CALIBRATION COLUMN
FS FLOW SWITCH
FM FLOWMETER
S STEAM SEPARATOR/SILENCER
CV CONTROL VALVE
PLC PROGRAMMABLE LOGIC CONTROLLER
FLT FILTER
BACKFLOW PREVENTER
A AGITATOR
THREADED CONNECTION
A
H
HT
P
T N
ANTI-SWEAT
THERMAL EFFICIENCY
THERMAL EFFICIENCY W/ HEAT TRACE
BURN PROTECTION
HEAT TRACED
NONE
PT BURN PROTECTION W/ HEAT TRACE
F FREEZE PROTECTION
INSULATION PURPOSE
SANITARY DIAPHRAGM SEAL
SANITARY CLAMP
CONNECTION
NS NITROGEN SUPPLY
MR MIXED REFRIGERANT
MS MEDIUM PRESSURE STEAM
N NITROGEN
NA CAUSTIC
POWS POTABLE WATER
BW BASIN WATER
DBB DOUBLE BLOCK AND BLEED
EFSO EMERGENCY FUEL SHUT OFF
GAL GALLONS
GPM GALLONS PER MINUTE
P&ID PIPING AND INSTRUMENT DIAGRAM
SCV SOLENOID CONTROL VALVE
TRV THERMAL RELIEF VALVE
CENTRIFUGAL PUMP
FUEL HOSE
SAMPLE CONNECTIONS
OA OUTDOOR AIR
RSRL REFRIGERANT SUCTION / REFRIGERANT LIQUID
SA SUPPLY AIR
V VENT
EA EXHAUST AIR
DFS DIESEL FUEL SUPPLY
DFR DIESEL FUEL RECIRCULATION
DFO DIESEL FUEL OFFLOAD
DFGR DIESEL FUEL GENERATOR RETURN
ULSD ULTRA LOW SULFUR DIESEL
AHU AIR HANDLING UNIT
BPV BACK PRESSURE VALVE
CU CONDENSING UNIT
EF EXHAUST FAN
FCU FAN COIL UNIT
MD MOTORIZED DAMPER
PSV PRESSURE SAFETY RELIEF VALVE
TU TERMINAL UNIT
FCV FLOW CONTROL VALVE
HLV HIGH LEVEL SHUT OFF VALVE
MAV MANUAL AIR VENT
SRV SAFETY RELIEF VALVE
BUILDING CODE
BUILDING CODE
BUILDING CODE
BUILDING CODE
BUILDING CODES
ELVW ELEVATOR - WEST
CRAL CRANE RAIL
DWPH DEWATERING PUMPHOUSE
RETW SITE RETAINING WALLS
DWPW PUMPWELL / DISCHARGE CULVERT
DD5 DRY DOCK (+ EAST ENTRANCE)
SUBX SUBSTATION X
DGPL DIESEL GENERATOR PLANT
REST RESTROOM
BWTS BASIN STORMWATER COLLECTION SYSTEM AREA
CAIS CAISSON
CSPH CHILLER PUMPHOUSE
DDMS MISC. DRY DOCK APPURTENANCES
ELVS ELEVATOR - SOUTH
LPA LOW PRESSURE AIR BUILDING
EHE E-HOUSE EAST
EHW E-HOUSE WEST
QWSC QUAYWALLS / TEMP BILKHEAD
CHW CHILLED WATER
CHWR CHILLED WATER RETURN
CHWS CHILLED WATER SUPPLY
FM GALLERY DRAINAGE FORCE MAIN
W POTABLE WATER
AL LOW PRESSURE COMPRESSED AIR
FI
LE
N
AM
E:
Z
:\C lie nts \A
NF
\U
SN
av y\H aw
\12
_P
HN
SY
D0 5\D es ign
\M ec h\S he ets \M
Z8
.dw g
LA
YO
UT
N
AM
E:
B
AS
IN
W
AT
ER
T
RE
AT
ME
NT
P&
ID
LE
GE
ND
SH
EE
T 1 O
F
PL
OT
TE
D:
T hu rsd ay
, M ay
, 2
1 -
:17 am U
SE
R:
cs till
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
UNCLASSIFIED//FOR OFFICIAL USE ONLY
U N
C
LA
SS
IF
IE
D
//F O
R O
FF
IC
IA
L
U
SE
O N
LY
UNCLASSIFIED//FOR OFFICIAL USE ONLY
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
M
AK
AL
AP
A, H
AW
AI
I
PE
AR
L
H
AR
BO
R
N
AV
AL
S
H
IP
YA
R
D
IM
F
N
AV
FA
C
P
AC
IF
IC
DR
Y
DO
CK
R
EP
LA
CE
M
EN
T
N O
T
FO
R
CO
N
ST
RU
CT
IO
N
P R
E L
IM
IN
A
R Y
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWING35% SUBMITTAL - 3 JUNE 2021
ALG
B A
S
IN
W A
TE
R
T R
E A
TM
E
N T
P
ID
L
E G
E N
D
SASSAS CLS
MZ800
PNEUMATIC SIGNAL
ELECTRIC SIGNAL
HYDRAULIC SIGNAL
SOFTWARE OR DATA LINK
MECHANICAL LINK
INSTRUMENT SUPPLY OR
ELECTROMAGNETIC, SONIC,
OPTICAL, OR NUCLEAR SIGNAL
INSTRUMENTS PLC
INTERLOCK
HARDWARE
DISCRETESHARED
DISPLAYDISCRETE
SINGLE SOLENOID
MOTOR OPERATED
HANDWHEEL - USED
WITH ANY ACTUATOR
A
MEASURED OR
INITIATING VARIABLE
FIRST LETTER
MODIFIER
SUCCEEDING LETTERS
READOUT OR
PASSIVE FUNCTION
OUTPUT
FUNCTION MODIFIER
ALARM
B BURNER, FLAME, COMBUSTION USER'S CHOICE USER'S CHOICE USER'S CHOICE
ANALYSIS
C CONTROL
D DIFFERENTIAL
E F
VOLTAGE SENSOR (PRIMARY ELEMENT)
FLOW RATE
G USER'S CHOICE OR GLASS,
VIEWING DEVICE
H HAND HIGH
I CURRENT (ELECTRICAL) INDICATE
J POWER SCAN
K TIME, TIME SCHEDULE CONTROL STATION
L LOWLIGHTLEVEL
M USER'S CHOICE (TYPICALLY MOMENTARY MIDDLE,
INTERMEDIATE
N USER'S CHOICE USER'S CHOICE USER'S CHOICE USER'S CHOICE
O P Q
R
USER'S CHOICE ORIFICE, RESTRICTION
PRESSURE, VACUUM POINT (TEST) CONNECTION
QUANTITY OR HEAT DUTY
RADIATION RECORD
S T U V
W X
SPEED, FREQUENCY SAFETY SWITCH
TEMPERATURE TRANSMIT
MULTIVARIABLE MULTIFUNCTION MULTIFUNCTION MULTIFUNCTION
WEIGHT, FORCE WELL
UNCLASSIFIED UNCLASSIFIED UNCLASSIFIED UNCLASSIFIEDX AXIS
Y Y AXISEVENT, STATE OR PRESENCE
Z Z AXISPOSITION, DIMENSION
RATIO
(FRACTION)
TIME RATE
OF CHANGE
INTEGRATE,
TOTALIZE
VALVE, DAMPER,
LOUVER
CONVERT
RELAY,
COMPUTE,
DRIVER,
ACTUATOR,
UNCLASSIFIED
FINAL CONTROL
ELEMENT
ORIFICE
ELECTROMAGNETIC
TURBINE OR PROPELLER
ULTRASONIC
VORTEX
GENERAL SYMBOL
IN-LINE ELEMENT
XX = FS, FG, FE, FT
XXXX = MASS, CORIOLIS,
XXXX
XXXX = MASS, CORIOLIS,
THERMAL...
XXXX
CLOSED
OPEN
MANUAL OPERATOR
AND CONTROL
(DCS)
LOCATION/ACCESSIBILITY
FIELD MOUNTED
1.
2.
FIELD OR LOCALLY MOUNTED.
1. DOCK CONTROL PANEL (DCP)
DEVICE.
CENTRAL OR MAIN CONTROL ROOM.
REAR OF PANEL OR CABINET
MOUNTED.
1.
2.
3. NOT VISIBLE ON VIDEO DISPLAY.
OPERATOR AT DEVICE OR CONSOLE.
NOT NORMALLY ACCESSIBLE TO AN4.
FIELD OR LOCAL CONTROL PANEL.
1.
2.
3. FRONT OF SECONDARY OR LOCAL
PANEL MOUNTED.
4. VISIBLE ON VIDEO DISPLAY.
ACCESSIBLE TO AN OPERATOR AT5.
DEVICE OR CONSOLE.
FIELD OR LOCAL CONTROL PANEL.
1.
2.
3.
4.
5.
REAR OF SECONDARY OR LOCAL
NOT VISIBLE ON VIDEO DISPLAY.
NOT NORMALLY ACCESSIBLE TO AN
OPERATOR AT DEVICE OR CONSOLE.
PANEL OR CABINET MOUNTED.
SECONDARY OR LOCAL CONTROL ROOM.
GALLERY CONTROL PANEL (GCP).
CONNECTION TO PROCESS
THERMAL, INT. ORIFICE ...
* = H/L
FLOW SWITCH
INSTRUMENT LINE SYMBOLS PRIMARY ELEMENT
MISCELLANEOUS SYMBOLS
CONTROL VALVE
SELF-ACTUATED DEVICES GENERAL INSTRUMENT SYMBOLS
INSTRUMENT IDENTIFICATION LETTERS
USER'S CHOICE (TYPICALLY
CONDUCTIVITY - ELECTRICAL)
USER'S CHOICE (TYPICALLY
DENSITY OR SPECIFIC GRAVITY)
MOISTURE OR HUMIDITY)
DIVERT
THROUGH
PRIMARY LOCATION NORMALLY
ACCESSIBLE TO AN OPERATOR
PRIMARY LOCATION NORMALLY
INACCESSIBLE TO AN OPERATOR
AUXILIARY LOCATION NORMALLY
ACCESSIBLE TO AN OPERATOR
AUXILIARY LOCATION NORMALLY
INACCESSIBLE TO AN OPERATOR
IN-LINE FLOW ELEMENT
WITH INTEGRAL TRANSMITTER
IN-LINE FLOW ELEMENT
WITH SEPARATE TRANSMITTER
DUAL FUNCTION OR INSTRUMENTS
SHARING COMMON HOUSING
PILOT LIGHT OR GAUGE GLASS ILLUMINATOR
UNDEFINED INTERLOCK LOGIC
INSTRUMENT WITH LONG TAG NUMBER
FT
FT
XX
FE
FS*
ANALYSIS
VIBRATION, MECHANICAL
ACCESSIBLE TO AN OPERATOR AT
GAUGING (DIMENSIONAL)
M
S
OR SAFETY VALVE
PRESSURE RELIEF
FC
1230-99
NOTES:
1. REFERENCE ISA S5.1, S5.2 &S5.3.
2. FLOW ASSUMED LEFT TO RIGHT AS SHOWN.
3. MULTIPLE LOCATIONS OF THE SAME TYPE CAN BE DISTINGUISHED BY ADDING A
LABEL OR NOTE.
M
I
ELECTRIC SIGNAL DISCRETE
VERTICAL
END-SUCTION
PUMP
SUMP PUMP
ELECTRIC MOTOR
EQUIPMENT SYMBOLS
VERTICAL TURBINE
PUMP
SYMBOL NOMENCLATURE
PB3
DCP
TOR
(V)
FUNCTION CLARIFICATION
TOR = TORQUE
ON = STATUS IS ON
OFF = STATUS IS OFF
SPECIAL DESIGNATION
(V) = VENDOR TO PROVIDE WITH
EQUIPMENT
HAND SWITCH NOMENCLATURE
PANEL OR POSITION DESIGNATOR
DCP = DOCK CONTROL PANEL IN BUILDING 5142
(PUMP STATION)
GCP = GALLERY CONTROL PANEL
PCP = PUMP CONTROL PANEL (LOCAL TO PUMP)
C = CLOSED POSITION
O = OPEN POSITION
HAND SWITCH NOMENCLATURE
PB3
PB ONE PUSHBUTTON
PB2 TWO PUSHBUTTONS
PB3 THREE PUSHBUTTONS
SW SELECTOR SWITCH - TWO POSITION
SW3 SELECTOR SWITCH - THREE POSITION
HOA HAND-OFF-AUTO (SELECTOR SWITCH - THREE POS.)
HA HAND-AUTO (SELECTOR SWITCH - TWO POS.)
S/S START/STOP (TWO PUSHBUTTONS)
O/R OVERRIDE (SELECTOR SWITCH - TWO POS.)
SEE SEQUENCE FOR DESCRIPTION AND FUNCTIONALITY OF BUTTONS AND SELECTOR
SWITCHES
REDUCED VOLTAGE,
SOLID STATE STARTER
PUSHBUTTON
SELECTOR SWITCH
KEYED SELECTOR SWITCH
ACTUATOR SYMBOLS
SYMBOLS (FLOW)
HORIZONTAL
END-SUCTION
PUMP
CENTRIFUGAL PUMP
FI
ROTOMETER
SELF-CONTAINED PRESSURE
REGULATING VALVE VALVE
VACUUM RELIEF
POSITIVE
DISPLACEMENT
PUMP
HYDRAULIC CONTROL VALVE
POSITIVE DISPLACEMENT METERFM
THERMAL RELIEF,
AUTOMATIC AIR VENT
B A
S
IN
W A
TE
R
T R
E A
TM
E
N T
P
ID
L
E G
E N
D
MZ801
FI
LE
N
AM
E:
Z
:\C lie nts \A
NF
\U
SN
av y\H aw
\12
_P
HN
SY
D0 5\D es ign
\M ec h\S he ets \M
Z8
.dw g
LA
YO
UT
N
AM
E:
B
AS
IN
W
AT
ER
T
RE
AT
ME
NT
P
&I D
LE
GE
ND
SH
EE
T 2 O
F
PL
OT
TE
D:
T hu rsd ay
, M ay
, 2
1 -
:17 am U
SE
R:
cs till
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
UNCLASSIFIED//FOR OFFICIAL USE ONLY
U N
C
LA
SS
IF
IE
D
//F O
R O
FF
IC
IA
L
U
SE
O N
LY
UNCLASSIFIED//FOR OFFICIAL USE ONLY
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
M
AK
AL
AP
A, H
AW
AI
I
PE
AR
L
H
AR
BO
R
N
AV
AL
S
H
IP
YA
R
D
IM
F
N
AV
FA
C
P
AC
IF
IC
DR
Y
DO
CK
R
EP
LA
CE
M
EN
T
N O
T
FO
R
CO
N
ST
RU
CT
IO
N
P R
E L
IM
IN
A
R Y
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWING35% SUBMITTAL - 3 JUNE 2021
ALG
BASIN WATER
FROM PUMPHOUSE
K MZ806
REJECT
FROM FILTER TRAIN B
J MZ805
REJECT
FROM FILTER TRAIN A
4"
BWTS-BW-V-150
4"
BWTS-BW-V-151
LSHH
LT
4"
BWTS-BW-V-152
8"
BWTS-BW-V-153
4"
BWTS-BW-V-154
8"
BWTS-BW-V-155
6"
BWTS-BW-V-156
6"
BWTS-BW-V-157
6"
BWTS-BW-V-158
LI
LAL
LAH
LAHH
1/2
BW
TS
-B W
-V -1
4"
BWTS-BW-V-176
BWTS-BW-8"-316SS-003-N
A MZ803
TO OWS FEED PUMPS
BASIN WATER
FROM GALLERIES
G MZ804
RECIRC
FROM GOWS/FILTERS
8"
BWTS-BW-V-230
4"
BW
TS
-B W
-V -2
BWTS-BW-T-101
CONCRETE TANK
CONTAINMENT
BW
-8
"-3
SS
-0
-N
BW
TS
-B W
-8 "-3
SS
-0
-N
BW
-4
"-3
SS
-0
-N
6"
BWTS-BW-V-233
6"
BWTS-BW-V-234
BWTS-BW-6"-316SS-007-N BWTS-BW-6"-316SS-008-N
BW
TS
-B W
-6 "-3
SS
-0
-N
6"
BWTS-BW-V-235
6"
BWTS-BW-V-236
6"
BWTS-BW-V-237
24" MW
24" MW24" MW
24" MW
24" MW24" MW
CONCRETE TANK
CONTAINMENT
OV
ER
FL
OW
OV
ER
FL
OW
BWTS-BW-6"-316SS-012-N
C MZ803
CONTAINMENT STORMWATER
TO BWTS STORAGE TANKS
6"
BWTS-BW-V-001
4"
BW
TS
-B W
-V -0
6"
BWTS-BW-V-002
M1
N1
N2
N3 N4
N5
N6
N7
N8
M2
N9
M3 N11
N10
M1
N6
N2
N3 N4
N5
N8
M2
N9
M3 N11
N10
N1
N7
N12 N12
BWTS-BW-T-102
4"
BW
TS
-B W
-V -1
BWTS-BW-6"-316SS-011-N
BWTS-BW-4"-316SS-006-N
BWTS-BW-4"-316SS-004-N
MZ802
SAS
SAS CLS
NOT TO SCALEA1 PIPING AND INSTRUMENTATION DIAGRAM - BASIN WATER STORAGE TANKS
B A
S
IN
W A
TE
R
T R
E A
TM
E
N T
P
ID
FI
LE
N
AM
E:
Z
:\C lie nts \A
NF
\U
SN
av y\H aw
\12
_P
HN
SY
D0 5\D es ign
\M ec h\S he ets \M
Z8
.dw g
LA
YO
UT
N
AM
E:
B
AS
IN
W
AT
ER
T
RE
AT
ME
NT
P
&I D
PL
OT
TE
D:
T hu rsd ay , M ay
, 2
1 -
:19 am
U
SE
R:
cs till
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
UNCLASSIFIED//FOR OFFICIAL USE ONLY
U N
C
LA
SS
IF
IE
D
//F O
R O
FF
IC
IA
L
U
SE
O N
LY
UNCLASSIFIED//FOR OFFICIAL USE ONLY
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
M
AK
AL
AP
A, H
AW
AI
I
PE
AR
L
H
AR
BO
R
N
AV
AL
S
H
IP
YA
R
D
IM
F
N
AV
FA
C
P
AC
IF
IC
DR
Y
DO
CK
R
EP
LA
CE
M
EN
T
N O
T
FO
R
CO
N
ST
RU
CT
IO
N
P R
E L
IM
IN
A
R Y
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWING35% SUBMITTAL - 3 JUNE 202135% SUBMITTAL - 3 JUNE 2021 (PACKAGE A)
6"
BWTS-BW-V-161
6"
BWTS-BW-V-162
6"x. .x6"
.x6"
PI
BW
TS
-B W
-V -1
1/2
BW
TS
-B W
-V -1
HS
HOA
S/S
RUN
HA
IN-AUTO
XA
FAULT
6"
BWTS-BW-V-167
6"
BWTS-BW-V-168
6"
BWTS-BW-V-169
6"
BWTS-BW-V-170
1/2
BW
TS
-B W
-V -1
1/2
BW
TS
-B W
-V -1
?-BW-P-101
BWTS-BW-P-102
. MZ802
BASIN WATER
FROM BASIN WATER
STORAGE TANKS
BWTS-BW-PSV-250
BWTS-BW-PSV-251
1/2
BW
TS
-B W
-V -1
BW-6"-316SS-013-N
BW
-6
"-3
SS
-N
6"
BW
TS
-B W
-V -1
1/2
BW
TS
-B W
-V -1
M
FE
FIT
C MZ802
CONTAINMENT STORMWATER
TO BWTS STORAGE TANKS
4"
BW
TS
-B W
-V -0
4"
BW
TS
-B W
-V -0
4"
BW
TS
-B W
-V -0
4"
BW
TS
-B W
-V -0
4"
BW
TS
-B W
-V -0
4"
BW
TS
-B W
-V -0
4"
BW
TS
-B W
-V -0
4"
BW
TS
-B W
-V -0
BWTS CONTAINMENT
STORMWATER
BWTS CONTAINMENT
STORMWATER
1/2"
BWTS-BW-V-011
1/2"
BWTS-BW-V-014
1/2"
BWTS-BW-V-017
1/2"
BWTS-BW-V-020
1/2"
BWTS-BW-V-021
1/2"
BWTS-BW-V-022
?-?-P-401 ?-BW-P-402 BWTS-BW-P-301 BWTS-BW-P-302
BWTS-BW-P-401/402
BWTS EQUIPMENT CONTAINMENT
AREA SUMP
BWTS-BW-P-301/302
BWTS TANK CONTAINMENT
AREA SUMP
VFD
VFD
TE
ME
SC
FIC
COMMON
ALARM
LSLL
LSL
LSH
COMMON
ALARM
LSLL
LSL
LSH
BWTS-BW-6"-316SS-011-N
BWTS-BW-4"-316SS-022-N
6"x6"
BWTS-BW-6"-316SS-023-N
B MZ804
BASIN WATER
TO OWS
MZ803
SAS
SAS CLS
NOT TO SCALEA1 PIPING AND INSTRUMENTATION DIAGRAM - OWS FEED PUMPS
FI
LE
N
AM
E:
Z
:\C lie nts \A
NF
\U
SN
av y\H aw
\12
_P
HN
SY
D0 5\D es ign
\M ec h\S he ets \M
Z8
.dw g
LA
YO
UT
N
AM
E:
B
AS
IN
W
AT
ER
T
RE
AT
ME
NT
P
&I D
PL
OT
TE
D:
T hu rsd ay , M ay
, 2
1 - 1:
pm
U
SE
R:
cs till
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
UNCLASSIFIED//FOR OFFICIAL USE ONLY
U N
C
LA
SS
IF
IE
D
//F O
R O
FF
IC
IA
L
U
SE
O N
LY
UNCLASSIFIED//FOR OFFICIAL USE ONLY
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
M
AK
AL
AP
A, H
AW
AI
I
PE
AR
L
H
AR
BO
R
N
AV
AL
S
H
IP
YA
R
D
IM
F
N
AV
FA
C
P
AC
IF
IC
DR
Y
DO
CK
R
EP
LA
CE
M
EN
T
N O
T
FO
R
CO
N
ST
RU
CT
IO
N
P R
E L
IM
IN
A
R Y
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWING35% SUBMITTAL - 3 JUNE 2021
B A
S
IN
W A
TE
R
T R
E A
TM
E
N T
P
ID
B MZ803
FROM INFLUENT PUMPS
E MZ805
BASIN WATER
TO FILTER TRAIN A
F MZ806
BASIN WATER
TO FILTER TRAIN B
6"
BWTS-BW-V-210
6"
BWTS-BW-V-211
6"x8"
6"x8"
4"
BW
-V -2
4"
BW
TS
-B W
-V -2
3"
BW
TS
-B W
-V -2
3"
BW
TS
-B W
-V -2
8"
BWTS-BW-V-218
8"
BWTS-BW-V-219
1/2
BW
TS
-B W
-V -2
6"
BWTS-BW-V-221
BW
TS
-B W
-V -2
BW
TS
-B W
-V -2
1/2
BW
TS
-B W
-V -2
8"
BWTS-BW-V-226
8"
BWTS-BW-V-227
8"x6"
1/2
BW
TS
-B W
-V -2
BW
TS
-B W
-V -2
4"x6"
4"x6"
DRAIN
1/2
BW
TS
-B W
-V -0
1/2
BW
TS
-B W
-V -2
DRAIN
DRAIN
DRAIN
DRAIN
6"
BWTS-BW-V-005
6"
BWTS-BW-V-007
6"
BWTS-BW-V-004
6"
BWTS-BW-V-006
BWTS-BW-P-201
BWTS-BW-P-202
TR
UC
K
LO
AD
IN
G
TR
UC
K
LO
AD
IN
G
TR
UC
K
LO
AD
IN
G
TR
UC
K
LO
AD
IN
G
6"
BWTS-BW-V-241
6"
BW
TS
-B W
-V -2
BWTS-BW-GOWS-201
BWTS-BW-GOWS-202
GMZ802
RECIRC
TO BW STORAGE TANKS FROM FILTERS/TO SANITARY
SEWER
BYPASS/RECIRC
MZ806H
8"x6"
1/2
BW
TS
-B W
-V -0
LIT
GWR
SELECT
FIC
SELECT
LIT
GWR
MZ804
SAS
SAS CLS
NOT TO SCALEA1 PIPING AND INSTRUMENTATION DIAGRAM - OIL/WATER SEPARATORS
FI
LE
N
AM
E:
Z
:\C lie nts \A
NF
\U
SN
av y\H aw
\12
_P
HN
SY
D0 5\D es ign
\M ec h\S he ets \M
Z8
.dw g
LA
YO
UT
N
AM
E:
B
AS
IN
W
AT
ER
T
RE
AT
ME
NT
P
&I D
PL
OT
TE
D:
T hu rsd ay , M ay
, 2
1 -
:21 am
U
SE
R:
cs till
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
UNCLASSIFIED//FOR OFFICIAL USE ONLY
U N
C
LA
SS
IF
IE
D
//F O
R O
FF
IC
IA
L
U
SE
O N
LY
UNCLASSIFIED//FOR OFFICIAL USE ONLY
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
M
AK
AL
AP
A, H
AW
AI
I
PE
AR
L
H
AR
BO
R
N
AV
AL
S
H
IP
YA
R
D
IM
F
N
AV
FA
C
P
AC
IF
IC
DR
Y
DO
CK
R
EP
LA
CE
M
EN
T
N O
T
FO
R
CO
N
ST
RU
CT
IO
N
P R
E L
IM
IN
A
R Y
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWING35% SUBMITTAL - 3 JUNE 2021 Xref ..\..\_WkSpace\Borders\DRYDP209-1676443-G-BS-BMcD.dwg
B A
S
IN
W A
TE
R
T R
E A
TM
E
N T
P
ID
INSTRUMENT AIR
FROM HEADER
E MZ804
BASIN WATER
FROM DISC FILTER FEED
PUMPS
DISC FILTER
MODULE #1
DISC FILTER
MODULE #2
DISC FILTER
MODULE #3
DISC FILTER
MODULE #4
DISC FILTER
MODULE #5
DISC FILTER
MODULE #6
DISC FILTER
MODULE #1
DISC FILTER
MODULE #2
DISC FILTER
MODULE #3
DISC FILTER
MODULE #4
DISC FILTER
MODULE #5
DISC FILTER
MODULE #6
DISC FILTER
MODULE #7
6" x8
6"
BW
TS
-B W
-V -1
6" x8
6"
BWTS-BW-V-191
6"
BWTS-BW-V-192
J MZ802
FILTER BACKWASH
TO BWTS STORAGE TANKS
4"
BWTS-BW-V-193
3"x4"3"
BWTS-BW-V-194
6"
BW
TS
-B W
-V -1
CONTROL
VALVES
TO
6"
BW
TS
-B W
-V -1
CONTROL
VALVES
TO
I MZ806
FILTRATE
TO DISCHARGE
6"
BW
TS
-B W
-V -1
BWTS-BW-FLT-301
BWTS-BW-FLT-401
1/2"
BWTS-BW-V-243
DRAIN
1/2
BW
TS
-B W
-V -2
DRAIN
1/2
BW
TS
-B W
-V -2
DRAIN
1/2
BW
TS
-B W
-V -2
SV
DPSH
START
STOP
NOT
READY
BACKWASH
STATUS
HS
E-STOP
HS
IN-PROGRESS
MA
LOP
BWTS-BW-6"-316SS-024-N
MZ805
B A
S
IN
W A
TE
R
T R
E A
TM
E
N T
P
ID
SAS
SAS CLS
NOT TO SCALEA1 PIPING AND INSTRUMENTATION DIAGRAM - FILTER TRAIN A
FI
LE
N
AM
E:
Z
:\C lie nts \A
NF
\U
SN
av y\H aw
\12
_P
HN
SY
D0 5\D es ign
\M ec h\S he ets \M
Z8
.dw g
LA
YO
UT
N
AM
E:
B
AS
IN
W
AT
ER
T
RE
AT
ME
NT
P
&I D
PL
OT
TE
D:
T hu rsd ay , M ay
, 2
1 -
:22 am
U
SE
R:
cs till
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
UNCLASSIFIED//FOR OFFICIAL USE ONLY
U N
C
LA
SS
IF
IE
D
//F O
R O
FF
IC
IA
L
U
SE
O N
LY
UNCLASSIFIED//FOR OFFICIAL USE ONLY
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
M
AK
AL
AP
A, H
AW
AI
I
PE
AR
L
H
AR
BO
R
N
AV
AL
S
H
IP
YA
R
D
IM
F
N
AV
FA
C
P
AC
IF
IC
DR
Y
DO
CK
R
EP
LA
CE
M
EN
T
N O
T
FO
R
CO
N
ST
RU
CT
IO
N
P R
E L
IM
IN
A
R Y
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWING35% SUBMITTAL - 3 JUNE 202135% SUBMITTAL - 3 JUNE 2021 (PACKAGE A)
INSTRUMENT AIR
FROM HEADER
F MZ804
BASIN WATER
FROM DISC FILTER FEED
PUMPS
DISC FILTER
MODULE #1
DISC FILTER
MODULE #2
DISC FILTER
MODULE #3
DISC FILTER
MODULE #4
DISC FILTER
MODULE #5
DISC FILTER
MODULE #6
DISC FILTER
MODULE #1
DISC FILTER
MODULE #2
DISC FILTER
MODULE #3
DISC FILTER
MODULE #4
DISC FILTER
MODULE #5
DISC FILTER
MODULE #6
DISC FILTER
MODULE #7
6" x8
6"
BW
TS
-B W
-V -2
6" x8
6"
BWTS-BW-V-201
6"
BWTS-BW-V-202
K MZ802
FILTER BACKWASH
TO BWTS STORAGE TANKS
4"
BWTS-BW-V-203
3"x4"3"
BWTS-BW-V-204
6"
BW
TS
-B W
-V -2
CONTROL
VALVES
TO
6"
BW
TS
-B W
-V -2
CONTROL
VALVES
TO
I MZ805
FILTRATE
FROM FILTER TRAIN A
TREATED WATER
TO SANITARY SEWER
6"
V-
FROM GOWS FEED PUMPS/TO
BW STORAGE TANKS
BYPASS/RECIRC
MZ804H
1/2
BW
TS
-B W
-V -2
1/2
BW
TS
-B W
-V -2
BPV-001
6"
BWTS-BW-V-248
4"
BW
TS
-B W
-V -2
6"
BW
TS
-B W
-V -2
1/2
BW
TS
-B W
-V -2
DRAIN
1/2
BW
TS
-B W
-V -2
DRAIN
1/2"
BWTS-BW-V-253
DRAIN
DRAIN DRAIN
BWTS-BW-FLT-302
BWTS-BW-FLT-402
HS
HS
FAULTMA
LOP
MZ806
SAS
SAS CLS
NOT TO SCALEA1 PIPING AND INSTRUMENTATION DIAGRAM - FILTER TRAIN B
B A
S
IN
W A
TE
R
T R
E A
TM
E
N T
P
ID
FI
LE
N
AM
E:
Z
:\C lie nts \A
NF
\U
SN
av y\H aw
\12
_P
HN
SY
D0 5\D es ign
\M ec h\S he ets \M
Z8
.dw g
LA
YO
UT
N
AM
E:
B
AS
IN
W
AT
ER
T
RE
AT
ME
NT
P
&I D
PL
OT
TE
D:
T hu rsd ay , M ay
, 2
1 -
:22 am
U
SE
R:
cs till
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
UNCLASSIFIED//FOR OFFICIAL USE ONLY
U N
C
LA
SS
IF
IE
D
//F O
R O
FF
IC
IA
L
U
SE
O N
LY
UNCLASSIFIED//FOR OFFICIAL USE ONLY
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
M
AK
AL
AP
A, H
AW
AI
I
PE
AR
L
H
AR
BO
R
N
AV
AL
S
H
IP
YA
R
D
IM
F
N
AV
FA
C
P
AC
IF
IC
DR
Y
DO
CK
R
EP
LA
CE
M
EN
T
N O
T
FO
R
CO
N
ST
RU
CT
IO
N
P R
E L
IM
IN
A
R Y
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWING35% SUBMITTAL - 3 JUNE 202135% SUBMITTAL - 3 JUNE 2021 (PACKAGE A)
BWTS CONTAINMENT STORM
WATER
GALLERY STORM WATER AND
SEEPAGE
DD5 STORM WATER AND
SEEPAGE
D D
VFD
BWTS-BW-GOWS-201/202
OIL/WATER SEPARATORS
BWTS-BW-T-101/102
BASIN WATER STORAGE
TANKS
BWTS-BW-P-201/202
DISC FILTER FEED
PUMPS
VAC TRUCK
M
FT
BWTS-BW-P-301/302/401/402
BWTS CONTAINMENT
SUMPS
DD5-SD-SP-001A/B - 012A/B
GALLERY SUMPS
DWPH-BW-P-1,2,3,4
PUMPHOUSE WET
WELLS
BWTS-BW-FLT-401/402
DISC FILTER STAGE 2
BWTS-BW-FLT-301/302
DISC FILTER STAGE 1
TREATED WATER
TO SANITARY SEWER
OIL
SOLIDS
FILTER BACKWASH
BWTS-BW-P-101/102
GOWS FEED PUMPS
BYPASS / RECIRCULATION
BYPASS / RECIRCULATION
MZ807
SAS
SAS CLS
NOT TO SCALEA1 PROCESS FLOW DIAGRAM - BASIN WATER TREATMENT SYSTEM
B A
S
IN
W A
TE
R
T R
E A
TM
E
N T
P R
O C
E S
S F
LO
W
D
IA
G R
A M
FI
LE
N
AM
E:
Z
:\C lie nts \A
NF
\U
SN
av y\H aw
\12
_P
HN
SY
D0 5\D es ign
\M ec h\S he ets \M
Z8
.dw g
LA
YO
UT
N
AM
E:
B
AS
IN
W
AT
ER
T
RE
AT
ME
NT
P
FD
P
LO
TT
ED
: T hu rsd ay , M ay
, 2
1 -
:23 am
U
SE
R:
cs till
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
UNCLASSIFIED//FOR OFFICIAL USE ONLY
U N
C
LA
SS
IF
IE
D
//F O
R O
FF
IC
IA
L
U
SE
O N
LY
UNCLASSIFIED//FOR OFFICIAL USE ONLY
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
M
AK
AL
AP
A, H
AW
AI
I
PE
AR
L
H
AR
BO
R
N
AV
AL
S
H
IP
YA
R
D
IM
F
N
AV
FA
C
P
AC
IF
IC
DR
Y
DO
CK
R
EP
LA
CE
M
EN
T
N O
T
FO
R
CO
N
ST
RU
CT
IO
N
P R
E L
IM
IN
A
R Y
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWING35% SUBMITTAL - 3 JUNE 202135% SUBMITTAL - 3 JUNE 2021 (PACKAGE A)
MZ808
FI
LE
N
AM
E:
Z
:\C lie nts \A
NF
\U
SN
av y\H aw
\12
_P
HN
SY
D0 5\D es ign
\M ec h\S he ets \M
Z8
.dw g
LA
YO
UT
N
AM
E:
B
AS
IN
W
AT
ER
S
EQ
UE
NC
E
OF
O
PE
RA
TI
ON
S
P
LO
TT
ED
: T hu rsd ay
, M ay
, 2
1 -
:24 am U
SE
R:
cs till
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
UNCLASSIFIED//FOR OFFICIAL USE ONLY
U N
C
LA
SS
IF
IE
D
//F O
R O
FF
IC
IA
L
U
SE
O N
LY
UNCLASSIFIED//FOR OFFICIAL USE ONLY
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
M
AK
AL
AP
A, H
AW
AI
I
PE
AR
L
H
AR
BO
R
N
AV
AL
S
H
IP
YA
R
D
IM
F
N
AV
FA
C
P
AC
IF
IC
DR
Y
DO
CK
R
EP
LA
CE
M
EN
T
N O
T
FO
R
CO
N
ST
RU
CT
IO
N
P R
E L
IM
IN
A
R Y
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWING35% SUBMITTAL - 3 JUNE 2021
ACRONYMS:
· BWTS - BASIN WATER TREATMENT SYSTEM
· HOA - HAND-OFF-AUTO
· OWS - OIL/WATER SEPARATOR
· PCS - PLANT CONTROL SYSTEM
· PLC - PROGRAMMABLE LOGIC CONTROLLER
· VFD - VARIABLE FREQUENCY DRIVE
SEQUENCE OF OPERATION - BASIN WATER STORAGE TANKS
1 GENERAL DESCRIPTION
1.1 COLLECT WATER FROM SUMP PUMPS AND SERVE AS THE FEED SOURCE FOR DOWNSTREAM OIL/WATER SEPARATORS.
1.2 TWO WATER STORAGE TANKS (T-101, T-102).
1.3 HYDRAULICALLY CONNECTED WITH MANUAL ISOLATION VALVES.
1.4 LEVEL TRANSMITTER ON EACH STORAGE TANK FOR CONTINUOUS LEVEL READING.
1.5 LEVEL SWITCH ON EACH STORAGE TANK FOR HIGH-HIGH LEVEL ALARM.
2 CONTROL DESCRIPTION
2.1 NO CONTROL FUNCTIONS ASSOCIATED WITH THE STORAGE TANKS.
2.2 LEVEL IN EACH STORAGE TANK FLUCTUATES WITHIN A SPECIFIED RANGE (BETWEEN HIGH AND LOW TANK LEVELS) BY OPERATION OF
DOWNSTREAM OWS FEED PUMP(S). WHEN BOTH TANKS ARE CONNECTED HYDRAULICALLY, THE LEVEL IN BOTH TANKS SHOULD BE
APPROXIMATELY THE SAME.
2.3 ALARMS AND MONITORING
2.3.1 THE FOLLOWING ALARMS AND STATUSES ARE MONITORED BY THE PCS:
2.3.1.1 TANK LEVEL
2.3.1.2LOW TANK LEVEL ALARM
2.3.1.3HIGH TANK LEVEL ALARM
2.3.1.4HIGH-HIGH TANK LEVEL ALARM
SEQUENCE OF OPERATION - OWS FEED PUMPS
1 GENERAL DESCRIPTION
1.1 CONVEY WATER FROM BASIN WATER STORAGE TANKS TO OIL/WATER SEPARATORS.
1.2 TWO POSITIVE DISPLACEMENT (PD) PUMPS (P-101, P-102) FOR DUTY/STANDBY OPERATION.
1.3 DUTY/STANDBY PUMP SELECTION FROM THE PCS.
1.4 VFD FOR FLOW CONTROL.
1.5 DOWNSTREAM FLOW METER (FIT) AT PUMP DISCHARGE.
2 CONTROL DESCRIPTION
2.1 EACH PUMP CAN BE OPERATED IN HAND OR REMOTE MODE VIA LOCAL HOA SWITCH. EACH PUMP CAN BE INDEPENDENTLY OPERATED IN HAND
MODE.
2.1.1 IN-HAND: PUMP STARTS WHEN HOA SWITCH IS PLACED IN HAND POSITION. PUMP STOPS WHEN HOA SWITCH IS PLACED IN OFF POSITION.
2.1.2 OFF: PUMP STOPS.
2.1.3 IN-AUTO: DUTY PUMP VARIES SPEED TO MAINTAIN DISCHARGE FLOW. DOWNSTREAM FLOW METER PROVIDES THE FEEDBACK FOR PUMP SPEED.
2.1.4 PUMP CAN OPERATE IN ONE OF THREE OPERATIONS: BYPASS, RECIRCULATION, AND FEED FORWARD. WHEN IN BYPASS, PUMP DISCHARGE
BYPASSES THE OIL/WATER SEPARTOR TO GO DIRECTLY TO SANITARY SEWER. WHEN IN RECIRCULATION, PUMP DISCHARGE RETURNS BACK TO THE BASIN WATER STORAGE TANKS. BOTH BYPASS AND RECIRCULATION FLOW PATHS REQUIRES OPERATION OF MANUAL VALVES. WHEN IN FEED
FORWARD, PUMP DISCHARGE FLOWS TO THE OIL/WATER SEPARATORS.
2.2 INTERLOCK
2.2.1 WHEN OPERATING IN AUTO MODE, THE DUTY PUMP SHUTS DOWN WHEN THE TANK LEVEL IN THE UPSTREAM BASIN WATER STORAGE TANKS
DROPS TO LOW-LOW LEVEL (XX'-XX”).
2.3 ALARMS AND MONITORING
2.3.1 THE FOLLOWING ALARMS AND STATUSES ARE MONITORED BY THE PCS:
2.3.1.1 VFD FAULT
2.3.1.2 RUN STATUS
2.3.1.3 IN-AUTO STATUS
SEQUENCE OF OPERATION - OIL/WATER SEPARATORS
1 GENERAL DESCRIPTION
1.1 SEPARATE FREE OIL FROM BASIN WATER.
1.2 TWO OIL/WATER SEPARATORS (GOWS-201, GOWS-202).
1.3 EACH OWS UNIT CAN OPERATE AT REDUCED LOAD WHEN BOTH UNITS ARE IN-SERVICE OR AT FULL LOAD WHEN ONE UNIT IS
OUT-OF-SERVICE.
1.4 FREE OIL AND OWS EFFLUENT WATER ARE COLLECTED IN SEPARATE CHAMBERS WITHIN EACH OWS UNIT. FREE OIL CHAMBER IS
MANUALLY EMPTIED WHEN FULL. OWS EFFLUENT WATER IS PUMPED TO DISC FILTERS BY DISC FILTER FEED PUMPS.
1.5 LEVEL SWITCH IN EACH OWS FOR HIGH-HIGH OWS LEVEL ALARM.
1.6 LEVEL SWITCH IN THE FREE OIL CHAMBER OF EACH OWS FOR HIGH-HIGH OIL LEVEL ALARM.
1.7 LEVEL TRANSMITTER IN THE OWS EFFLUENT WATER CHAMBER OF EACH OWS FOR CONTINUOUS LEVEL READING.
2 CONTROL DESCRIPTION
2.1 NO CONTROL FUNCTIONS ASSOCIATED WITH THE OWS UNITS.
2.2 LEVEL IN EACH OWS EFFLUENT WATER CHAMBER IS MAINTAINED BY DOWNSTREAM DISC FILTER FEED PUMP(S). WHEN BOTH OWS UNTS ARE
CONNECTED HYDRAULICALLY, THE LEVEL IN BOTH EFFLUENT WATER CHAMBERS SHOULD BE APPROXIMATELY THE SAME.
2.3 HIGH-HIGH OIL LEVEL ALARM PROMPTS PERSONNEL THAT THE OIL CHAMBER IS FULL AND REQUIRES PUMP OUT BY VAC TRUCK.
2.4 ALARMS AND MONITORING
2.4.1 THE FOLLOWING ALARMS AND STATUSES ARE MONITORED BY THE PCS:
2.4.1.1EFFLUENT WATER LEVEL
2.4.1.2LOW EFFLUENT WATER LEVEL ALARM
2.4.1.3HIGH EFFLUENT WATER LEVEL ALARM
2.4.1.4HIGH-HIGH OWS LEVEL ALARM
2.4.1.5HIGH-HIGH OIL LEVEL ALARM
SEQUENCE OF OPERATION - DISC FILTER FEED PUMPS
1 GENERAL DESCRIPTION
1.1 CONVEY OWS EFFLUENT WATER FROM OWS TO DISC FILTERS FOR FURTHER FILTRATION/TREATMENT.
1.2 TWO HORIZONTAL CENTRIFUGAL PUMPS (P-201, P-202) FOR DUTY/STANDBY OPERATION.
1.3 DUTY/STANDBY PUMP SELECTION FROM THE PCS.
1.4 VFD CONTROL TO MAINTAIN UPSTREAM WATER LEVEL IN THE OWS EFFLUENT WATER CHAMBER.
2 CONTROL DESCRIPTION
2.1 EACH PUMP CAN BE OPERATED IN HAND OR REMOTE MODE VIA LOCAL HOA SWITCH. EACH PUMP CAN BE INDEPENDENTLY OPERATED IN HAND
MODE.
2.1.1 IN-HAND: PUMP STARTS WHEN HOA SWITCH IS PLACED IN HAND POSITION. PUMP STOPS WHEN HOA SWITCH IS PLACED IN OFF POSITION.
2.1.2 OFF: PUMP STOPS.
2.1.3 IN-AUTO: DUTY PUMP VARIES SPEED TO MAINTAIN LEVEL IN THE OWS EFFLUENT WATER CHAMBER OF OWS UNITS. THE LEVEL
TRANSMITTER IN THE OWS EFFLUENT WATER CHAMBER PROVIDES THE LEVEL FEEDBACK FOR PUMP SPEED.
2.2 INTERLOCK
2.2.1 WHEN OPERATING IN AUTO MODE, THE DUTY PUMP SHUTS DOWN WHEN THE LEVEL IN THE OWS EFFLUENT WATER CHAMBER IN OWS UNITS
DROPS TO LOW-LOW LEVEL (XX'-XX”).
2.3 ALARMS AND MONITORING
2.3.1 THE FOLLOWING ALARMS AND STATUSES ARE MONITORED BY THE PCS:
2.3.1.1 VFD FAULT
2.3.1.2RUN STATUS
2.3.1.3IN-AUTO STATUS
SEQUENCE OF OPERATION - DISC FILTERS
1 GENERAL DESCRIPTION
1.1 FILTRATE OWS EFFLUENT PRIOR TO DISCHARGE TO SANITARY SEWER.
1.2 TWO DISC FILTER UNITS (FLT-301, FLT-401) ON TRAIN “A” AND TWO DISC FILTER UNITS (FLT-302, FLT-402) ON TRAIN “B”.
1.3 EACH TRAIN SUPPLIED WITH ON-BOARD PLC.
1.4 SOLENOID OPERATED ON/OFF VALVES FOR FILTRATION/BACKWASH OPERATIONS.
1.5 DIFFERENTIAL PRESSURE SWITCH TO MONITOR PRESSURE ACROSS DISC FILTERS.
2 CONTROL DESCRIPTION
2.1 VENDOR SUPPLIED PLC ON EACH TRAIN CONTROLS THE ASSOCIATED DISC FILTERS. EACH PLC IS A STANDALONE SYSTEM SPECIFICALLY
PROGRAMMED TO OPERATE TWO DISC FILTERS INSTALLED ON THE TRAIN.
2.2 EACH DISC FILTER CAN OPERATE IN FILTRATION OR BACKWASH MODE. NO MORE THAN ONE FILTER IS IN BACKWASH MODE AT ANY GIVEN TIME.
2.3 VENDOR SUPPLIED PLC PERFORMS ALL CONTROL FUNCTIONS FOR FILTRATION AND BACKWASH OPERATIONS. AUTOMATED ON/OFF VALVES ARE
CONTROLLED IN SEQUENCE FOR FILTRATION AND BACKWASH OPERATION.
2.4 ALARMS AND MONITORING
2.4.1 THE FOLLOWING ALARMS AND STATUSES ARE MONITORED BY THE PCS:
2.4.1.1BACKWASH IN-PROGRESS
2.4.1.2BACKWASH FAULT
SEQUENCE OF OPERATION - BWTS EQUIPMENT/TANK CONTAINMENT SUMP PUMPS
1 GENERAL DESCRIPTION
1.1 COLLECT SURFACE RUNOFF AND CONVEY COLLECTED WATER TO BASIN WATER STORAGE TANKS.
1.2 EACH SUMP PUMP STATION OUTFITTED WITH LEAD/LAG PUMPS.
1.3 PUMP CONTROL WITH THREE (3)-LEVEL FLOAT SWITCHES: LEAD PUMP ON, LAG PUMP ON, PUMPS OFF.
1.4 PUMPS ALTERNATE LEAD/LAG ON SUBSEQUENT STARTS TO EQUALIZE RUNTIME.
1.5 SEAL LEAK AND HIGH TEMPERATURE DETECION FOR EACH PUMP.
1.6 LEVEL FLOAT SWITCH FOR LOCAL HIGH-HIGH LEVEL ALARM.
2 CONTROL DESCRIPTION
2.1 EACH PUMP CAN BE OPERATED IN HAND OR REMOTE MODE VIA LOCAL HOA SWITCH. EACH PUMP CAN BE INDEPENDENTLY OPERATED IN HAND
MODE.
2.1.1 IN-HAND: PUMP STARTS WHEN HOA SWITCH IS PLACED IN HAND POSITION. PUMP STOPS WHEN HOA SWITCH IS PLACED IN OFF POSITION.
2.1.2 OFF: PUMP STOPS.
2.1.3 IN-AUTO: LEAD PUMP STARTS WHEN THE SUMP LEVEL REACHES “LEAD PUMP ON” FLOAT SWITCH. WHEN THE SUMP LEVEL REACHES “LAG
PUMP ON” FLOAT SWITCH WITH LEAD PUMP RUNNING, LAG PUMP STARTS. ALL PUMPS STOP WHEN THE LEVEL DROPS TO “PUMPS OFF”
FLOAT SWITCH.
2.2 SUMP PUMP OPERATION IS INDEPENPENT OF OPERATIONS DOWNSTREAM OF THE SUMP PUMPS. NO INTERLOCK WITH DOWNSTREAM PROCESS IS
PROVIDED.
2.3 ALARMS AND MONITORING
2.3.1 THE FOLLOWING ALARMS AND STATUSES ARE DISPLAYED (VIA VISUAL/AUDIBLE DEVICES) AT THE LOCAL PUMP CONTROL PANEL:
2.3.1.1HIGH-HIGH SUMP LEVEL
2.3.1.2PUMP RUN STATUS
2.3.1.3HIGH WINDING TEMPERATURE
2.3.1.4PUMP SEAL LEAK
2.3.2 THE FOLLOWING ALARMS AND STATUSES ARE MONITORED BY THE PCS:
2.3.2.1COMMON ALARM (HIGH-HIGH SUMP LEVEL, PUMP SEAL LEAK, HIGH WINDIGN TEMPERATURE)
2.3.2.2PUMP RUN STATUS
1676443
1. THESE GENERAL NOTES APPLY TO ALL MECHANICAL DRAWINGS IN THIS SET.
SHEET SPECIFIC NOTES ARE INDICATED ON EACH SHEET UNDER GENERAL
SHEET NOTES.
2. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR
REQUIRED TO PROVIDE COMPLETE AND OPERABLE MECHANICAL SYSTEMS AS
INDICATED AND REQUIRED BY CODE.
3. PROVIDE ALL MECHANICAL EQUIPMENT AND APPURTENANCES IN ACCORDANCE
WITH MANUFACTURER'S RECOMMENDATIONS, AS INDICATED, AND AS
REQUIRED BY CODE. WHERE THE ABOVE REQUIREMENTS ARE IN CONFLICT,
PROVIDE THE MOST STRINGENT.
4. PROVIDE VIBRATION ISOLATORS FOR ALL MECHANICAL EQUIPMENT TO
PREVENT TRANSMISSION OF VIBRATION TO BUILDING STRUCTURE.
5. PROVIDE ACCESS PANELS IN WALLS AND CEILINGS WHERE REQUIRED TO
SERVE FIRE DAMPERS, VALVES, SMOKE DETECTORS, AND OTHER CONCEALED
MECHANICAL EQUIPMENT THAT REQUIRES ROUTINE MAINTENANCE. ACCESS
PANELS MUST BE LARGE ENOUGH TO ALLOW PROPER CLEARANCE FOR
ACCESS DOORS.
6. ALL OPENINGS IN FIRE WALLS DUE TO DUCTWORK, PIPING, CONDUIT, ETC.,
MUST BE FIRE STOPPED.
7. LOCATE NEW HORIZONTAL DUCTWORK ABOVE THE SUSPENDED CEILINGS
UNLESS OTHERWISE INDICATED.
8. 90 DEGREE MITERED DUCT ELBOWS IN THE SUPPLY AND RETURN DUCT SHALL
HAVE TURNING VANES.
9. PROVIDE PIPE SLEEVES FOR ALL PIPING PENETRATIONS THROUGH WALLS AND
FLOORS. EACH PIPE SHALL BE SEPARATELY SLEEVED. PROVIDE CONTINUOUS
SEALANT JOINT AROUND PIPE SLEEVE, BOTH SIDES OF WALL, WATERTIGHT.
10. AFTER THE PIPING IS INSULATED, PROVIDE FACTORY-FABRICATED PIPE
LABELS, WITH DIRECTION OF FLOW ARROWS, ON THE FOLLOWING PIPING, AT
10 FOOT ON CENTER ON THE PIPING MAINS AND 5 FOOT ON CENTER ON THE
BRANCH RUNOUTS FROM THE MAINS.
11. DUCT RUNOUT SIZE TO DIFFUSER, REGISTER, OR GRILLE MUST BE THE SAME
AS NECK SIZE.
12. MOUNT SHUTOFF SWITCHES AND EMERGENCY SHUTOFF SWITCHES 48 INCHES
ABOVE FINISHED FLOOR UNLESS OTHERWISE INDICATED. REFER TO
ELECTRICAL DRAWINGS FOR LOCATION OF LIGHT SWITCHES AND COORDINATE.
13. SLOPE CONDENSATE PIPING 1/8 INCH PER FOOT DOWNWARD IN THE DIRECTION
OF FLOW. PROVIDE CLEANOUTS AT EACH CHANGE IN DIRECTION GREATER
THAN 45 DEGREES OR ONCE EVERY 45 FEET OF LINEAR PIPE LENGTH. UTILIZE
COMBINATION WYE AND 1/8 BENDS SHALL BE USED IN LIEU OF TEES.
14. PROVIDE LOUVER PLENUMS WITH MINIMUM 1/4 INCH PER FOOT SLOPE
DOWNWARDS TOWARDS EXTERIOR FOR DRAINAGE.
15. SEAL UNUSED PORTIONS OF LOUVERS WITH INSULATED METAL BLANK-OFF
PANELS.
16. MECHANICAL DRAWINGS ARE SCHEMATIC IN NATURE AND MAY NOT SHOW
EVERY OFFSET, FITTING, AND CONNECTION NECESSARY FOR A COMPLETE
INSTALLATION. PROVIDE ADDITIONAL OFFSETS, FITTINGS, AND CONNECTIONS
REQUIRED FOR COMPLETE AND OPERABLE SYSTEM.
17. VERIFY AND COORDINATE INSTALLATION OF MECHANICAL SYSTEMS WITH
OTHER TRADES PRIOR TO BEGINNING WORK. WORK MUST PROVIDE ACCESS
FOR MAINTENANCE WITHOUT REQUIRING REMOVAL OR DISASSEMBLY OF
ADJACENT SYSTEMS.
GENERAL MECHANICAL NOTES
° DEGREES
Ø DIAMETER
AD ACCESS DOOR
AFF ABOVE FINISHED FLOOR
AP ACCESS PANEL
APD AIR PRESSURE DROP
AS AIR SEPARATOR
ATFP ANTITERRORISM FORCE PROTECTION
ASW AUXILARY SEAWATER - CLOSED LOOP
ASWR AUXILARY SEAWATER - CLOSED LOOP RETURN
ASWS AUXILARY SEAWATER - CLOSED LOOP SUPPLY
BD BALANCING DAMPER
BHP BRAKE HORSEPOWER
BOD BOTTOM OF DUCT
BTUH BRITISH THERMAL UNITS PER HOUR
C COMMON
Cv LOSS COEFFICIENT
CFM CUBIC FEET PER MINUTE
CLG CEILING
COP COEFFICIENT OF PERFORMANCE
CU CONDENSING UNIT
D CONDENSATE DRAIN
DB DRY BULB
DDC DIRECT DIGITAL CONTROL
DEG DEGREE
DP DIFFERNTIAL PRESSURE
EAT ENTERING AIR TEMPERATURE
EF EXHAUST FAN
EFF EFFECTIVENESS
EQPT EQUIPMENT
ESP EXTERNAL STATIC PRESSURE
EWT ENTERING WATER TEMPERATURE
F FAHRENHEIT
FD FIRE DAMPER
FT FEET
FT WG FEET WATER GAUGE
GPM GALLONS PER MINUTE
HGT HEIGHT
HR HOUR, HUMIDITY RATIO
IAW IN ACCORDANCE WITH
IWG INCHES WATER GAUGE
kW KILOWATT
LAT LEAVING AIR TEMPERATURE
LBS POUNDS
LV LOUVER
LWT LEAVING WATER TEMPERATURE
MAX MAXIMUM
MCWB MEAN COINCIDENT WET BLUB
MD MOTORIZED DAMPER
MIN MINIMUM
N NORTH
NC NORMALLY CLOSED, NOISE CRITERIA
NMC NON-MECHANICAL COOLING
NO NUMBER, NORMALLY OPEN
OA OUTSIDE AIR
PH PHASE
PSI POUNDS PER SQUARE INCH
QTY QUANTITY
RA RETURN AIR
RH RELATIVE HUMIDITY
SA SUPPLY AIR
SCHW SHORE CHILLED WATER
SCHWR SHORE CHILLED WATER RETURN
SCHWS SHORE CHILLED WATER SUPPLY
SIM SIMILAR
SP STATIC PRESSURE
SQ SQUARE
TYP TYPICAL
UOI UNLESS OTHERWISE INDICATED
V VOLTS
VFD VARIABLE FREQUENCY DRIVE
W WIDTH, WEST
WB WET BULB
WPD WATER PRESSURE DROP
MECHANICAL ABBREVIATIONS
T
HUMIDITY SENSORH
THERMOSTAT
ROUND DUCT DIMENSION
RECTANGULAR DUCT DIMENSIONS (INCHES)
FLEXIBLE ROUND DUCT (5'-0" MAX LENGTH)
12x10
12"Ø
SUPPLY DUCT DOWN/UP
DOWNWARD DIRECTION OF SLOPED PIPING
RETURN DUCT DOWN/UP
GLOBE VALVE
GATE VALVE
BUTTERFLY VALVE
CHECK VALVE
PRESSURE REDUCING VALVE
DRAIN VALVE WITH HOSE CONNECTION
2-WAY CONTROL VALVE
3-WAY CONTROL VALVE
BACKFLOW PREVENTER
RELIEF VALVE
MANUAL AIR VENT
AUTOMATIC AIR VENT
WYE STRAINER
STRAINER WITH BLOWDOWN VALVE
CLEAN OUT
PIPE REDUCER
ECCENTRIC REDUCER
UNION
PRESSURE GAUGE WITH SHUTOFF COCK
THERMOMETER
PIPE CAP
FLANGE
FLEXIBLE PIPE CONNECTOR
C.O.
EXHAUST DUCT DOWN/UP
M
M
MV
AV
R/D RISE (R) DROP (D) IN DIRECTION OF FLOW
ACCESS DOOR (AD), ACCESS PANEL (AP)
FIRE DAMPER
AD
FIRE /SMOKE DAMPER
SMOKE DAMPER
BD
BACKDRAFT DAMPER
OPEN/CLOSED CONTROL DAMPER, PARALLEL
BLADE, MOTOR OPERATED
MODULATING CONTROL DAMPER, OPPOSED
BLADE, MOTOR OPERATED
MANUAL BALANCE DAMPER
MANUAL CALIBRATED BALANCING VALVE
MECHANICAL LEGEND
BALL VALVE
DIFFERENTIAL PRESSURE SENSOR
DP
STATIC PRESSURE SENSOR
SP
PIPING TO BE REMOVED
MECHANICAL PIPING LEGEND
AUXILIARY SEAWATER
SHORE CHILLED WATER
ASW
SCHW
POINT OF CONNECTION
POINT OF DISCONNECTION
CONSTRUCTION INTERFACE
DEMO
WORK
EXISTING
TO REMAIN
WORK EXISTING
TO REMAIN
EXISTING TO REMAIN
DEMO WORK
WORK
ROOM TAG
DETAIL NUMBER
SHEET WHERE DRAWN
DETAIL TAG
ROOM NAME
ROOM NUMBER
DETAIL NUMBER
SCALE
SHEET
REFERENCED
FROM
SECTION TAG
SECTION NUMBER
SHEET WHERE DRAWN
GENERAL PROJECT SYMBOLS
NEW WORK
KEYNOTE TAG
KEYNOTE NUMBER
DEMO
KEYNOTE TAG
KEYNOTE NUMBER
? PHOTOGRAPH TAG
PHOTOGRAPH NUMBER
SHEET WHERE SHOWN
PLAN
NORTH
SCALE
TRUE NORTH
SHEET
REFERENCED
FROM
AIR DISTRIBUTION DEVICE
IDENTIFICATION
EQUIPMENT
IDENTIFICATION
LPA-AHP-T-001
SYSTEM CODE
EQUIPMENT
CODE
175 CFM
#Ø SA-# (?)
QTY
MARK
AIR FLOW
NECK SIZE
BUILDING CODE
SEQUENCE NUMBER 001-999
VALVE IDENTIFICATION
LPA-AHP-V-001
SYSTEM CODE
VALVE SEQUENCE NUMBER
BUILDING CODE
VALVE STATUS
NO NORMALLY OPEN
NC NORMALLY SHUT
LO LOCKED OPEN
LS LOCKED SHUT
VALVE FAIL POSITIONS
FO FAIL OPEN
FS FAIL SHUT
FAI FAIL AS IS
NOTE:
VENT, DRAIN, AND BYPASS VALVES
ARE NORMALLY CHUT AND ALL
OTHERS ARE NORMALLY OPEN
UNLESS SPECIFIED OTHERWISE
CEILING SUPPLY AIR DEVICE
CEILING RETURN AIR DEVICE
CEILING EXHAUST AIR DEVICE
SURFACE MOUNTED SUPPLY GRILLE
SURFACE MOUNTED RETURN/EXHAUST GRILLE
MECHANICAL LEGEND (CONT.)
BASIN WATER COLLECTION SYSTEM AREA
BUILDING CODES
CAISSON
CRANE RAIL
CAIS
CRAL
BWTS
CHILLER PUMPHOUSE
DRY DOCK (+EAST ENTRANCE)
MISC DRY DOCK APPURTENANCES
DD5
DDMS
CSPH
DEWATERING PUMPHOUSEDWPH
PUMPWELL/DISCHARGE CULVERTDWPW
E-HOUSE EASTEHE
E-HOUSE WESTEHW
ELEVATOR - SOUTHELVS
ELEVATOR - WESTELVW
LOW PRESSURE AIR BUILDINGLPA
QUAYWALLS/TEMP BULKHEADQWSC
RESTROOMREST
SITE RETAINING WALLSRETW
SUBSTATION X DIESEL GENERATOR PLANTSUBX
DIESEL GENERATOR PLANTDGPL
N O T F O R C O N S T R U C T
IO
N
P R E L
IM
IN
A R Y
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V F
A C
P A
C
IF
IC
AS NOTED
M A
K A
L A
P A
H
A W
A
II
P E
A R
L H
A R
B O
R N
A V
A L S
H
IP
Y A
R D
I
M F
D R Y D O C K R E P
LA
C E M E N T
1676443
UNCLASSIFIED//FOR OFFICIAL USE ONLY
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
UNCLASSIFIED//FOR OFFICIAL USE ONLY
U N
C L A
S S
IF
IE
D
F O
R O
F F
IC
IA
L U
S E
O N
L Y
P
LO
TT
E
D
FI
LE
N A
M E
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWING35% SUBMITTAL - 3 JUNE 2021
/2
/2
:3 :1
P
M C
R e v it
P ro je c ts
\D R
Y D
P
-1
-M
H -D
W P
H jh c h o ri k i.
rv t
MG001
P U
M P
H O
U S
E
M E
C H
A N
C
IA
L
LE
G E
N D
, A B
B R
E V
IA
T
IO
N
S A
N D
N O
T E
S
JJMKMM BEF
DWPH-HVAC-EF-01
DWPH-HVAC-EF-02
DWPH-HVAC-EF-03
DWPH-HVAC-EF-04
DWPH-HVAC-EF-05 DWPH-HVAC-EF-06
DWPH-HVAC-CU-01
DWPH-HVAC-DSS-01
DWPH-HVAC-DSS-02
DWPH-HVAC-CU-02
ELECTRICAL
BATTERY RM
TELCOM
005 BREAK RM
TLT
LOCKER
JAN
STOR
OFFICE
CORRIDOR
MECHANICAL PUMP
ROOM
CONTROL RM
DWPH-HVAC-CU-04
DWPH-HVAC-FCU-02
DWPH-HVAC-FCU-01
M
M
6ø SA-A (2)
160 CFM
8ø SA-A
145 CFM
6x8 RA-B
130 CFM
C3
MG301
10x8 RA-B
290 CFM6x6 EA-D
50 CFM
6x6 EA-F
70 CFM
6x6 SA-E
30 CFM
6x6 EA-D
40 CFM
6ø SA-C
50 CFM
6ø SA-A
120 CFM
L-02
U/L
U/L
10x10 TA
C1
MG301
L-01
A1
MG301
A3
MG301
6x6 SA-E
25 CFM
U/L
M
M
M
M1
8x6 SA
10x8 SA
9 8x6 OA
10x8 RA
8x6 EA 6x6 EA
M T
DWPH-HVAC-SF-01
DWPH-HVAC-SF-02
1…
This is the start of the file's text. The full file is on GovTribe.