This document contains pre-proposal questions and answers regarding solicitation number N62742-20-R-1303. Key details include that the solicitation is for the construction of two earth covered magazines and a production area shelter to support U.S. and Australian military training activities at Royal Australian Air Force Base Tindal in Northern Territory, Australia. The project scope also includes extending electrical and telecommunication services to the site from existing infrastructure and complying with Australian building and fire protection codes. Metal roofing panels for the project must be a minimum of 0.48mm thickness and meet specification requirements. Substitution of equivalent Australian testing standards may be considered if sufficient documentation is provided to show standards meet or exceed those listed in the specifications.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DEPARTMENT OF THE NAVY

NAVAL FACILITIES ENGINEERING COMMAND, PACIFIC

258 MAKALAPA DR., STE. 100

PEARL HARBOR, HI 96860-3134

Notice No. 4

10 February 2020

PRE-PROPOSAL QUESTIONS & ANSWERS

RFP N62742-20-R-1303

FY20 MCAF PAF180300, APSI EARTH COVERED MAGAZINES,

ROYAL AUSTRALIAN AIR FORCE BASE, TINDAL, AUSTRALIA

NOTE: The following questions and answers are provided for INFORMATION ONLY. The RFP remains unchanged unless it is amended in writing on a Standard Form 30.

28. Many of the tests required by specifications list ASTM standards or test methods. Will a similar AS (Australian Standard) test be acceptable? As an example, specification item 31 23

00.3.12.2.3 calls for density testing of backfill by ASTM D1556/D1556M. Would AS 1289

5.1.1 be an acceptable equivalent for density testing of the backfill?

ANSWER: Substitution of Australian testing standards or test methods for the US standards or test methods listed in the specifications may be considered provided the Contractor submits sufficient documentation confirming the alternate standard or test method meets or exceeds the requirements. See Specification Section 01 33 00 paragraph 1.9 for proposed variation procedure.

29. In Amendment 007, spec 07 41 13 reference to an Australian product (Colorbond) was removed. Drawing not for the metal panels on sheet A205 changed the thickness to 0.48mm while spec item 07 41 13.2.2.1 states the thickness to be 0.60mm. Please confirm thickness to be followed. Please note that the 0.48 mm thickness would be an Australian product (Colorbond), while the 0.60mm thickness would likely need to come from the US and may not align with some of the Australian Standards listed in this specification section.

ANSWER: Metal roofing panels are to be provided in 0.48mm thickness (min.) and comply with the requirements listed in the Specification. See Amendment No. 0008.