This is an Answers to Clarification Questions document (Amendment 0002) for the USNS PUERTO RICO (T-EPF 11) Regular Overhaul (ROH) solicitation N6264926RL012, issued by the Department of the Navy Naval Supply Systems Command. The document addresses specification clarifications and technical questions submitted by potential contractors regarding various maintenance and repair work items.
The clarifications cover four primary areas: Aviation Facility Support work requiring four overhead flood lights (Flood light assembly 506829-1 with amber filter MS24489-4 and NVD compatible blue filter 522936-1), four structure/deck wash flood lights with LSTSGU-3 power cables and NAVSEA SYM 720.3 plugs, two extended line up lights (Light fixture assembly 515364-1 with light bar assembly 617577-1), four deck mounted line up lights, and six deck mounted deck edge lights. For Waterjet Maintenance—Interim Docking, the document clarifies that Work Item 929A covers shipyard waterjet work while Work Item 992A covers OEM (Wartsila) support services during the 2.5-year maintenance period. For Sea Valve Inspection and Sea Chest work, contractors must provide 30 replacement CFM valves total: 25 Crane Model 025CG06431 (2.5" flanged valves, DI/BR/NBR material) and 5 Crane Model 03CG06431 (3" valves, Class 150 FF, DI/BR/EPDM material, per B16.24 specification). The place of performance is Thailand or South Korea, with the solicitation deadline extended to 22 June 2026 at 2:00 pm Singapore time.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACHMENT J-5
REQUEST FOR SPECIFICATION CLARIFICATION
SPECIFICATION ITEM NO.: N6264926RL012 PARA. NO. 7.4
TITLE: AVIATION FACILITY SUPPORT (1 YR)
QUESTION:
Kindly provide part number of the following;
| 7.4.1 | Four overhead flood lights. |
| 7.4.2 | Four structure/deck wash flood lights. |
| 7.4.3 | Two extended line up lights. |
| 7.4.4 | Four deck mounted line up lights. |
| 7.4.5 | Six deck mounted deck edge lights. |
ANSWER:
7.4.1 Four overhead flood lights.
Flood light assembly 506829-1. Lamp amber filter, MS24489-4 and NVD compatible blue filter 522936-1 can be ordered separately
7.4.2 Four structure/deck wash flood lights.
Flood light assembly is supplied without power cable. The power cable shall be LSTSGU-3, equipped with plug NAVSEA SYM 720.3
7.4.3 Two extended line up lights.
Light fixture assembly 515364-1 furnished with light bar assembly 617577-1
7.4.4 Four deck mounted line up lights.
7.4.5 Six deck mounted deck edge lights.
SPECIFICATION ITEM NO.: N6264926RL012 PARA. NO. 7.0
TITLE: WATERJET MAINTENANCE – INTERIM DOCKING (2.5 YR)
QUESTION:
Paragraph 7.1 states to provide the services of an OEM Wartsila field service representative to supervise the 2.5 -year maintenance of all four (4) waterjet units while in the drydock. This 2.5 year waterjet maintenance is already the scope of WI 0929
Paragraph 7.1.1 states maintenance period will include removal and reinstallation of all four (4) jetavator assemblies, replacement of four (4) water-lubricated bearings with journals and reassembly and full overhaul of the removed waterjets at DMS facility in Chesapeake. This conflicts the first paragraph that the overhaul will be done in drydock.
With this, we would like to clarify if this work item, similar to WI 0929A?
WI 929A covers the shipyard work on the waterjets WI 992A covers the OEM support
SPECIFICATION ITEM NO.: N6264926RL012 PARA. NO. 7.4.4
TITLE: INSPECT SEA VALVES AND SEA CHEST
QUESTION:
Paragraph 7.4.4 states to provide ten new CFM valves sized three inches and under with appropriate certificates. New valves shall be equal to removed valves and meet the same testing requirements of original valves. CFM replacement valves that fail testing shall be replaced by contractor, estimate a total of 30 valves will be required.
Please confirm whether we will provide 10 or 30 valves. Also provide specific valve specification for our reference.
Total number of valves required is 30.
25 each — 2.5” valves Model No.: 025CG06431 Manufacturer: Crane Type: Flanged Material: DI/BR/NBR
5 each — 3” valves Model No.: 03CG06431 Manufacturer: Crane Specification: B16.24, Class 150, FF Material: DI/BR/EPDM